Study guide

3.5 Single-DOF and 2-DOF Vibrations, Damping & Dynamic Balancing

PE Mechanical Exam

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Exam Overview, Reference Handbook & Mechanical Engineering Fundamentals

1.1 NCEES PE Mechanical CBT Format, Three Disciplines & Reference Handbook Strategy 1.2 Engineering Economics, Cash Flow & Project Evaluation and Scheduling 1.3 Units, Dimensional Analysis & Physical Constants 1.4 Statics, Dynamics & Mechanical Equilibrium

2 Chapter 2: Mechanical Design & Analysis (Stress, Failure Theories & Components)

2.1 Stress, Strain, Principal Stresses & Combined Loading 2.2 Static Failure Theories for Ductile and Brittle Materials 2.3 Fatigue Analysis, S-N Curves & Fluctuating Stresses 2.4 Pressure Vessels, Column Buckling & Spring Design 2.5 Threaded Fasteners, Welded Connections & Mechanical Joints

3 Chapter 3: Mechanical Power Transmission, Mechanisms & Vibrations

3.1 Shaft Sizing, Torsional Deflection & Critical Speeds 3.2 Spur, Helical, Bevel & Worm Gears and Epicyclic Gear Trains 3.3 Rolling-Element & Journal Bearings, Power Screws, Clutches, Brakes & Flywheels 3.4 Four-Bar Linkages, Cam-Follower Systems & Kinematics 3.5 Single-DOF and 2-DOF Vibrations, Damping & Dynamic Balancing

4 Chapter 4: Thermal & Fluid Systems

4.1 Fluid Statics, Manometry, Submerged Surfaces & Buoyancy 4.2 Incompressible Pipe Flow, Darcy-Weisbach & Minor Losses 4.3 Pump Selection, System Curves, NPSH & Cavitation 4.4 Steady & Transient Conduction, Forced & Natural Convection 4.5 Radiation Heat Transfer, View Factors & Heat Exchanger Sizing (LMTD/NTU)

5 Chapter 5: Power Plants & Energy Conversion Systems

5.1 Thermodynamic Properties, Pure Substances & 1st/2nd Laws 5.2 Vapor Power Cycles (Rankine, Superheat, Reheat & Regeneration) 5.3 Gas Power Cycles (Brayton, Otto, Diesel, Dual & Combined Cycle) 5.4 Combustion Stoichiometry, Flue Gas Analysis & Thermochemistry 5.5 Turbomachinery, Compressible Flow & Nozzles, Renewables & Energy Storage

6 Chapter 6: HVAC & Refrigeration Systems

6.1 Psychrometric Principles & Air-Conditioning Processes 6.2 Cooling & Heating Load Calculations (CLTD/SCL/CLF & Heat Balance) 6.3 Vapor-Compression Refrigeration Cycles & Refrigerant Properties 6.4 Refrigeration Equipment (Compressors, Evaporators, Condensers, Expansion Devices) & Safety Codes 6.5 Air Distribution, Duct Design, Fans & Hydronic Water Networks 6.6 Energy Recovery Devices, HVAC Acoustics & Vibration Isolation

7 Chapter 7: Materials, Manufacturing & Processing

7.1 Ferrous/Non-Ferrous Metals, Polymers, Ceramics & Composites 7.2 Iron-Carbon Equilibrium Phase Diagram & Heat Treatment Processes 7.3 Corrosion, Wear, Creep, Hydrogen Embrittlement & Fracture Mechanics 7.4 Casting, Metal Forming, Forging, Stamping & Powder Metallurgy 7.5 Machining Dynamics, Tool Wear, Welding Metallurgy & Non-Destructive Examination (NDE)

8 Chapter 8: Measurements, Controls, Codes & Engineering Ethics

8.1 Temperature, Pressure, Flow & Strain Transducers and Signal Conditioning 8.2 Feedback Control Loops, PID Tuning, Frequency Response & Stability 8.3 ASME Boiler & Pressure Vessel Code, ASHRAE, OSHA & NFPA Safety Standards 8.4 NCEES Model Rules, Engineering Ethics & Professional Seal Liability

3.5 Single-DOF and 2-DOF Vibrations, Damping & Dynamic Balancing

Key Takeaways Explain This Topic AI

The fundamental natural frequency of an SDOF system is ω n = k / m = g / δ s t \omega_n = \sqrt{k/m} = \sqrt{g/\delta_{st}} ω n ​ = k / m ​ = g / δ s t ​ ​ , where δ s t \delta_{st} δ s t ​ is the static deflection under gravity, providing a rapid calculation method ( f n ≈ 15.76 δ s t (mm) f_n \approx \frac{15.76}{\sqrt{\delta_{st}\text{ (mm)}}} f n ​ ≈ δ s t ​ (mm) ​ 15.76 ​ in SI, f n ≈ 3.127 δ s t (in) f_n \approx \frac{3.127}{\sqrt{\delta_{st}\text{ (in)}}} f n ​ ≈ δ s t ​ (in) ​ 3.127 ​ in US Customary).

The viscous damping ratio ζ = c / c c r = c / ( 2 k m ) \zeta = c / c_{cr} = c / (2\sqrt{km}) ζ = c / c cr ​ = c / ( 2 km ​ ) governs free decay: underdamped systems ( ζ < 1 \zeta < 1 ζ < 1 ) oscillate at damped natural frequency ω d = ω n 1 − ζ 2 \omega_d = \omega_n \sqrt{1 - \zeta^2} ω d ​ = ω n ​ 1 − ζ 2 ​ , with decay measured by logarithmic decrement δ = 1 n ln ⁡ ( x 0 / x n ) ≈ 2 π ζ \delta = \frac{1}{n} \ln(x_0/x_n) \approx 2\pi \zeta δ = n 1 ​ ln ( x 0 ​ / x n ​ ) ≈ 2 π ζ .

Steady-state forced vibration amplitude is governed by the Dynamic Magnification Factor D M F = 1 / ( 1 − r 2 ) 2 + ( 2 ζ r ) 2 DMF = 1 / \sqrt{(1 - r^2)^2 + (2\zeta r)^2} D MF = 1/ ( 1 − r 2 ) 2 + ( 2 ζ r ) 2 ​ ; at resonance ( r = ω / ω n = 1.0 r = \omega/\omega_n = 1.0 r = ω / ω n ​ = 1.0 ), response is strictly damping-limited ( D M F peak = 1 / ( 2 ζ ) DMF_{\text{peak}} = 1/(2\zeta) D M F peak ​ = 1/ ( 2 ζ ) ) with phase lag ϕ = 90 ∘ \phi = 90^\circ ϕ = 9 0 ∘ .

Vibration isolation occurs exclusively in the supercritical zone r > 2 r > \sqrt{2} r > 2 ​ where Transmissibility T R = 1 + ( 2 ζ r ) 2 ( 1 − r 2 ) 2 + ( 2 ζ r ) 2 < 1.0 TR = \sqrt{\frac{1 + (2\zeta r)^2}{(1 - r^2)^2 + (2\zeta r)^2}} < 1.0 TR = ( 1 − r 2 ) 2 + ( 2 ζ r ) 2 1 + ( 2 ζ r ) 2 ​ ​ < 1.0 ; all transmissibility curves intersect at T R = 1.0 TR = 1.0 TR = 1.0 when r = 2 r = \sqrt{2} r = 2 ​ .

In 2-DOF systems, a Frahm Tuned Mass Damper tuned to ω a = k 2 / m 2 = ω \omega_a = \sqrt{k_2/m_2} = \omega ω a ​ = k 2 ​ / m 2 ​ ​ = ω completely nullifies steady-state vibration of the primary mass ( X 1 = 0 X_1 = 0 X 1 ​ = 0 ), splitting the original resonance into two safe peak frequencies away from the excitation.

Last updated: August 2026

Single-DOF and 2-DOF Vibrations, Damping & Dynamic Balancing

Mechanical vibration is the oscillatory motion of dynamic systems about an equilibrium configuration. On the NCEES PE Mechanical exam, vibration and dynamics questions assess five essential topic areas: single-degree-of-freedom (SDOF) undamped and damped natural frequencies , viscous damping regimes and logarithmic decrement , harmonically excited steady-state forced response (Dynamic Magnification Factor) , vibration isolation and force transmissibility , and two-degree-of-freedom (2-DOF) tuned vibration absorbers and dynamic balancing . +---------------------------------------------------------------------------------------------------+

  • | MECHANICAL VIBRATIONS & DYNAMICS TAXONOMY |
  • | |
  • | [FREE SDOF VIBRATION] [DAMPING REGIMES] [FORCED RESONANCE] [ISOLATION & TMD] |
  • | - ODE: m*x'' + k*x = 0 - c_cr = 2*sqrt(k*m) - F(t) = F_0*sin(w*t) - r = w / w_n |
  • | - w_n = sqrt(k/m) - zeta = c / c_cr - DMF = 1/sqrt(...) - TR = sqrt(...) |
  • | - w_n = sqrt(g/delta_st) - Underdamped: zeta < 1 - Resonance at r = 1 - Isolation: r>sqrt2 |
  • | - Springs Ser/Parallel - Log Dec: delta = 2pi*z - Phase Lag: phi=90 deg - 2-DOF Tuned Damper |
  • +---------------------------------------------------------------------------------------------------+
  • 1. SDOF Free Undamped Vibration & Equivalent Stiffness

The fundamental mass-spring model represents an elastic structure of equivalent stiffness k k k supporting an inertial mass m m m . +---------------------------------------------------------------------------------------------------+

  • | SDOF MASS-SPRING-DAMPER MODEL |
  • | |
  • | +-----------------------+ |
  • | | FIXED CEILING | |
  • | +---+---------------+---+ |
  • | | | |
  • | Spring (k) [k] [c] Dashpot / Damper (c) |
  • | | | |
  • | +---+---------------+---+ |
  • | | MASS (m) | ---> Displacement x(t) |
  • | +-----------------------+ |
  • | | |
  • | v External Excitation: F(t) = F_0 * sin(w*t) |
  • +---------------------------------------------------------------------------------------------------+
  • Equation of Motion & Natural Frequency

Applying Newton's second law ( m x ¨ + k x = 0 m \ddot{x} + k x = 0 m x ¨ + k x = 0 ): ω n = k m ( rad/s ) , f n = ω n 2 π = 1 2 π k m ( Hz ) , T n = 1 f n = 2 π ω n ( seconds ) \omega_n = \sqrt{\frac{k}{m}} \quad (\text{rad/s}), \quad f_n = \frac{\omega_n}{2\pi} = \frac{1}{2\pi}\sqrt{\frac{k}{m}} \quad (\text{Hz}), \quad T_n = \frac{1}{f_n} = \frac{2\pi}{\omega_n} \quad (\text{seconds}) ω n ​ = m k ​ ​ ( rad/s ) , f n ​ = 2 π ω n ​ ​ = 2 π 1 ​ m k ​ ​ ( Hz ) , T n ​ = f n ​ 1 ​ = ω n ​ 2 π ​ ( seconds )

Static Deflection Equivalence ( δ s t \delta_{st} δ s t ​ )

Under gravity, static deflection is δ s t = m g k \delta_{st} = \frac{m g}{k} δ s t ​ = k m g ​ . Substituting k m = g δ s t \frac{k}{m} = \frac{g}{\delta_{st}} m k ​ = δ s t ​ g ​ provides a rapid shortcut to estimate natural frequency directly from measured static sag: ω n = g δ s t \omega_n = \sqrt{\frac{g}{\delta_{st}}} ω n ​ = δ s t ​ g ​ ​

In SI Units ( g = 9.81 m/s 2 g = 9.81\text{ m/s}^2 g = 9.81 m/s 2 , δ s t \delta_{st} δ s t ​ in mm): f n = 1 2 π 9810 δ s t (mm) ≈ 15.76 δ s t (mm) ( Hz ) f_n = \frac{1}{2\pi}\sqrt{\frac{9810}{\delta_{st}\text{ (mm)}}} \approx \frac{15.76}{\sqrt{\delta_{st}\text{ (mm)}}} \quad (\text{Hz}) f n ​ = 2 π 1 ​ δ s t ​ (mm) 9810 ​ ​ ≈ δ s t ​ (mm) ​ 15.76 ​ ( Hz )

In US Customary Units ( g = 386.4 in/s 2 g = 386.4\text{ in/s}^2 g = 386.4 in/s 2 , δ s t \delta_{st} δ s t ​ in inches): f n = 1 2 π 386.4 δ s t (in) ≈ 3.127 δ s t (in) ( Hz ) f_n = \frac{1}{2\pi}\sqrt{\frac{386.4}{\delta_{st}\text{ (in)}}} \approx \frac{3.127}{\sqrt{\delta_{st}\text{ (in)}}} \quad (\text{Hz}) f n ​ = 2 π 1 ​ δ s t ​ (in) 386.4 ​ ​ ≈ δ s t ​ (in) ​ 3.127 ​ ( Hz )

Equivalent Spring Stiffness Combinations ( k e q k_{eq} k e q ​ )

Configuration / Element Equivalent Stiffness ( k e q k_{eq} k e q ​ ) Physical Boundary Condition

Springs in Parallel k e q = k 1 + k 2 + ⋯ + k n k_{eq} = k_1 + k_2 + \dots + k_n k e q ​ = k 1 ​ + k 2 ​ + ⋯ + k n ​ Identical deflection ( x 1 = x 2 = x x_1 = x_2 = x x 1 ​ = x 2 ​ = x )

Springs in Series 1 k e q = 1 k 1 + 1 k 2 ⟹ k e q = k 1 k 2 k 1 + k 2 \frac{1}{k_{eq}} = \frac{1}{k_1} + \frac{1}{k_2} \implies k_{eq} = \frac{k_1 k_2}{k_1 + k_2} k e q ​ 1 ​ = k 1 ​ 1 ​ + k 2 ​ 1 ​ ⟹ k e q ​ = k 1 ​ + k 2 ​ k 1 ​ k 2 ​ ​ Shared load ( F 1 = F 2 = F F_1 = F_2 = F F 1 ​ = F 2 ​ = F )

Cantilever Beam (End Load) k = 3 E I L 3 k = \frac{3 E I}{L^3} k = L 3 3 E I ​ Shaft or bracket tip deflection

Simply Supported Beam (Center Load) k = 48 E I L 3 k = \frac{48 E I}{L^3} k = L 3 48 E I ​ Shaft mid-span between bearings

Fixed-Fixed Beam (Center Load) k = 192 E I L 3 k = \frac{192 E I}{L^3} k = L 3 192 E I ​ Clamped shaft mid-span

Torsional Shaft k t = G J L k_t = \frac{G J}{L} k t ​ = L G J ​ Rotational shaft stiffness ( N ⋅ m/rad \text{N}\cdot\text{m/rad} N ⋅ m/rad )

2. Viscous Damping & Response Regimes

Adding a linear viscous dashpot (damping force F d = − c x ˙ F_d = -c \dot{x} F d ​ = − c x ˙ ) yields the governing differential equation: m x ¨ + c x ˙ + k x = 0 ⟹ x ¨ + 2 ζ ω n x ˙ + ω n 2 x = 0 m \ddot{x} + c \dot{x} + k x = 0 \implies \ddot{x} + 2 \zeta \omega_n \dot{x} + \omega_n^2 x = 0 m x ¨ + c x ˙ + k x = 0 ⟹ x ¨ + 2 ζ ω n ​ x ˙ + ω n 2 ​ x = 0

Where:

Critical Damping Coefficient ( c c r c_{cr} c cr ​ ): The minimum damping required to prevent oscillatory motion. c c r = 2 m ω n = 2 k m c_{cr} = 2 m \omega_n = 2 \sqrt{k m} c cr ​ = 2 m ω n ​ = 2 km ​

Damping Ratio ( ζ \zeta ζ ): Dimensionless measure of damping severity. ζ = c c c r = c 2 m ω n = c 2 k m \zeta = \frac{c}{c_{cr}} = \frac{c}{2 m \omega_n} = \frac{c}{2 \sqrt{k m}} ζ = c cr ​ c ​ = 2 m ω n ​ c ​ = 2 km ​ c ​ +---------------------------------------------------------------------------------------------------+

  • | DAMPING RESPONSE CLASSIFICATIONS |
  • | |
  • | UNDERDAMPED (zeta < 1): CRITICALLY DAMPED (zeta = 1): OVERDAMPED (zeta > 1): |
  • | - Oscillatory decaying sine - Fastest return to equilibrium - Sluggish non-oscillatory decay |
  • | - w_d = w_n * sqrt(1-zeta^2) - No overshoot - Two real negative roots |
  • | - x(t) = X0*e^(-z*w_n*t)*cos - x(t) = (C1 + C2*t)*e^(-w_n*t) - x(t) = C1*e^(s1*t)+C2*e^(s2*t) |
  • +---------------------------------------------------------------------------------------------------+
  • Logarithmic Decrement ( δ \delta δ )

The rate of decay of underdamped free vibrations is measured by the natural log of the ratio of successive peak amplitudes separated by n n n cycles: δ = ln ⁡ ( x 1 x 2 ) = 1 n ln ⁡ ( x 0 x n ) = 2 π ζ 1 − ζ 2 \delta = \ln\left( \frac{x_1}{x_2} \right) = \frac{1}{n} \ln\left( \frac{x_0}{x_n} \right) = \frac{2 \pi \zeta}{\sqrt{1 - \zeta^2}} δ = ln ( x 2 ​ x 1 ​ ​ ) = n 1 ​ ln ( x n ​ x 0 ​ ​ ) = 1 − ζ 2 ​ 2 π ζ ​

Solving for damping ratio ζ \zeta ζ from measured log decrement δ \delta δ : ζ = δ ( 2 π ) 2 + δ 2 ≈ δ 2 π ( for light damping ζ < 0.20 ) \zeta = \frac{\delta}{\sqrt{(2\pi)^2 + \delta^2}} \approx \frac{\delta}{2\pi} \quad (\text{for light damping } \zeta < 0.20) ζ = ( 2 π ) 2 + δ 2 ​ δ ​ ≈ 2 π δ ​ ( for light damping ζ < 0.20 )

3. Harmonically Forced Vibration & Dynamic Magnification

Subjecting an SDOF system to harmonic excitation F ( t ) = F 0 sin ⁡ ( ω t ) F(t) = F_0 \sin(\omega t) F ( t ) = F 0 ​ sin ( ω t ) produces steady-state response x p ( t ) = X sin ⁡ ( ω t − ϕ ) x_p(t) = X \sin(\omega t - \phi) x p ​ ( t ) = X sin ( ω t − ϕ ) . +---------------------------------------------------------------------------------------------------+

  • | DYNAMIC MAGNIFICATION FACTOR (DMF) CURVES |
  • | |
  • | DMF (X / X_st) |
  • | ^ |
  • | 5 | | zeta = 0.1 (Peak DMF = 1/(2*zeta) = 5.0) |
  • | 4 | / \ |
  • | 3 | / \ |
  • | 2 | / \ zeta = 0.25 (Peak = 2.0) |
  • | 1 +---------+-------+---------------------------> Isolation Zone (r > sqrt(2)) |
  • | 0 0.5 1.0 1.414 (sqrt(2)) 2.0 3.0 Frequency Ratio r = w / w_n |
  • +---------------------------------------------------------------------------------------------------+
  • Steady-State Amplitude ( X X X ) and Dynamic Magnification Factor ( D M F DMF D MF )

Let X s t = F 0 k X_{st} = \frac{F_0}{k} X s t ​ = k F 0 ​ ​ be zero-frequency static deflection, and r = ω ω n r = \frac{\omega}{\omega_n} r = ω n ​ ω ​ be frequency ratio: X = F 0 / k ( 1 − r 2 ) 2 + ( 2 ζ r ) 2 = X s t × D M F X = \frac{F_0 / k}{\sqrt{(1 - r^2)^2 + (2\zeta r)^2}} = X_{st} \times DMF X = ( 1 − r 2 ) 2 + ( 2 ζ r ) 2 ​ F 0 ​ / k ​ = X s t ​ × D MF D M F = 1 ( 1 − r 2 ) 2 + ( 2 ζ r ) 2 DMF = \frac{1}{\sqrt{(1 - r^2)^2 + (2\zeta r)^2}} D MF = ( 1 − r 2 ) 2 + ( 2 ζ r ) 2 ​ 1 ​ Phase Angle ( ϕ ): tan ⁡ ϕ = 2 ζ r 1 − r 2 \text{Phase Angle (}\phi\text{): } \tan\phi = \frac{2 \zeta r}{1 - r^2} Phase Angle ( ϕ ): tan ϕ = 1 − r 2 2 ζ r ​

Three Dynamic Operating Regimes

Low Frequency ( r ≪ 1 r \ll 1 r ≪ 1 ): In phase ( ϕ ≈ 0 ∘ \phi \approx 0^\circ ϕ ≈ 0 ∘ ), governed strictly by stiffness ( X ≈ F 0 / k X \approx F_0 / k X ≈ F 0 ​ / k ).

Resonant Peak ( r ≈ 1 r \approx 1 r ≈ 1 ): Lags by ϕ = 90 ∘ \phi = 90^\circ ϕ = 9 0 ∘ , governed strictly by damping . At exact resonance ( r = 1 r = 1 r = 1 ): D M F resonance = 1 2 ζ = Q ( Quality Factor ) DMF_{\text{resonance}} = \frac{1}{2\zeta} = Q \quad (\text{Quality Factor}) D M F resonance ​ = 2 ζ 1 ​ = Q ( Quality Factor )

High Frequency ( r ≫ 1 r \gg 1 r ≫ 1 ): Out of phase ( ϕ ≈ 180 ∘ \phi \approx 180^\circ ϕ ≈ 18 0 ∘ ), governed strictly by mass inertia ( X → 0 X \to 0 X → 0 ).

4. Vibration Isolation & Force Transmissibility

Vibration isolation prevents machine dynamic forces from transmitting into the support structure. +---------------------------------------------------------------------------------------------------+

  • | FORCE TRANSMISSIBILITY (TR) MASTER CURVE |
  • | |
  • | Transmissibility TR |
  • | ^ |
  • | 4 | RESONANCE AMPLIFICATION ZONE VIBRATION ISOLATION ZONE |
  • | | (r < sqrt(2), TR > 1.0) (r > sqrt(2), TR < 1.0) |
  • | 3 | /\ |
  • | | / \ |
  • | 2 | / \ |
  • | 1 +--------------+------+-------+------------------------------------------ (TR = 1.0) |
  • | | / \ \ |
  • | 0 +------------+----------+-------+------------------------------> r = w / w_n |
  • | 0 0.5 1.0 1.414 (sqrt(2)) 2.0 3.0 |
  • +---------------------------------------------------------------------------------------------------+
  • The Transmissibility Equation ( T R TR TR )

The ratio of transmitted force F T F_T F T ​ to excitation force F 0 F_0 F 0 ​ is the Transmissibility ( T R TR TR ): T R = F T F 0 = 1 + ( 2 ζ r ) 2 ( 1 − r 2 ) 2 + ( 2 ζ r ) 2 TR = \frac{F_T}{F_0} = \sqrt{\frac{1 + (2\zeta r)^2}{(1 - r^2)^2 + (2\zeta r)^2}} TR = F 0 ​ F T ​ ​ = ( 1 − r 2 ) 2 + ( 2 ζ r ) 2 1 + ( 2 ζ r ) 2 ​ ​

For undamped or lightly damped isolators ( ζ ≈ 0 \zeta \approx 0 ζ ≈ 0 ): T R ≈ 1 ∣ 1 − r 2 ∣ = 1 r 2 − 1 ( for r > 2 ) TR \approx \frac{1}{|1 - r^2|} = \frac{1}{r^2 - 1} \quad (\text{for } r > \sqrt{2}) TR ≈ ∣1 − r 2 ∣ 1 ​ = r 2 − 1 1 ​ ( for r > 2 ​ )

The Fundamental Laws of Vibration Isolation

All transmissibility curves pass through T R = 1.0 TR = 1.0 TR = 1.0 at exact frequency ratio r = 2 ≈ 1.414 r = \sqrt{2} \approx 1.414 r = 2 ​ ≈ 1.414 , regardless of damping ζ \zeta ζ .

Vibration isolation occurs ONLY when r > 2 r > \sqrt{2} r > 2 ​ ( T R < 1.0 TR < 1.0 TR < 1.0 ). If r < 2 r < \sqrt{2} r < 2 ​ , mounting the machine on springs amplifies transmitted forces.

The Damping Paradox: In the isolation zone ( r > 2 r > \sqrt{2} r > 2 ​ ), increasing damping ζ \zeta ζ increases transmissibility T R TR TR (reducing isolation efficiency). However, damping is mandatory to suppress destructive resonance peaks when accelerating through r = 1 r = 1 r = 1 during startup and shut-down coast-down.

Isolation Efficiency ( η iso \eta_{\text{iso}} η iso ​ ) η iso = 1 − T R = 1 − 1 r 2 − 1 ⟹ r = 1 T R + 1 \eta_{\text{iso}} = 1 - TR = 1 - \frac{1}{r^2 - 1} \implies r = \sqrt{\frac{1}{TR} + 1} η iso ​ = 1 − TR = 1 − r 2 − 1 1 ​ ⟹ r = TR 1 ​ + 1 ​

5. Two-Degree-of-Freedom Systems & Tuned Mass Dampers

When a primary structure ( m 1 , k 1 ) (m_1, k_1) ( m 1 ​ , k 1 ​ ) experiences severe resonant vibration at excitation frequency ω = k 1 / m 1 \omega = \sqrt{k_1/m_1} ω = k 1 ​ / m 1 ​ ​ , an auxiliary Tuned Mass Damper (Frahm Dynamic Vibration Absorber) ( m 2 , k 2 ) (m_2, k_2) ( m 2 ​ , k 2 ​ ) can be attached. +---------------------------------------------------------------------------------------------------+

  • | FRAHM TUNED DYNAMIC VIBRATION ABSORBER (2-DOF) |
  • | |
  • | +-----------------------+ |
  • | | FIXED CEILING | |
  • | +-----------+-----------+ |
  • | | |
  • | Spring [k_1] |
  • | | |
  • | +-----------+-----------+ |
  • | | PRIMARY MASS (m_1) | <--- F(t) = F_0 * sin(w*t) |
  • | +-----------+-----------+ |
  • | | |
  • | Spring [k_2] (Absorber) |
  • | | |
  • | +-----------+-----------+ |
  • | | ABSORBER MASS (m_2) | |
  • | +-----------------------+ |
  • +---------------------------------------------------------------------------------------------------+
  • Absorber Sizing & Response Equations

Setting the absorber natural frequency equal to the excitation frequency: ω a = k 2 m 2 = ω \omega_a = \sqrt{\frac{k_2}{m_2}} = \omega ω a ​ = m 2 ​ k 2 ​ ​ ​ = ω

At this tuned condition, the steady-state amplitudes are: X 1 = 0 ( Primary mass comes to a COMPLETE STANDSTILL! ) X_1 = 0 \quad (\text{Primary mass comes to a COMPLETE STANDSTILL!}) X 1 ​ = 0 ( Primary mass comes to a COMPLETE STANDSTILL! ) X 2 = − F 0 k 2 ( Absorber spring force exactly cancels F 0 ) X_2 = -\frac{F_0}{k_2} \quad (\text{Absorber spring force exactly cancels } F_0) X 2 ​ = − k 2 ​ F 0 ​ ​ ( Absorber spring force exactly cancels F 0 ​ )

Important

Frequency Splitting: Adding the absorber eliminates vibration at ω \omega ω , but splits the original single resonance peak into two new resonant peaks ( ω 1 < ω < ω 2 \omega_1 < \omega < \omega_2 ω 1 ​ < ω < ω 2 ​ ). The system must operate at constant speed ω \omega ω without drifting into ω 1 \omega_1 ω 1 ​ or ω 2 \omega_2 ω 2 ​ .

6. Dynamic Balancing of Rotating Machinery

Static Unbalance (Single-Plane): The center of mass is offset from the rotational axis ( e ≠ 0 e \ne 0 e  = 0 ), producing a single rotating centrifugal force vector F ⃗ c = m e ω 2 \vec{F}_c = m e \omega^2 F c ​ = m e ω 2 . Corrected by adding or removing mass in one correction plane .

Dynamic Unbalance (Two-Plane): The principal inertia axis is both offset and skewed relative to the shaft rotational axis, producing both a net centrifugal force and a rotating dynamic couple (moment). Requires correction in two distinct axial planes using 4-run or vibration analyzer phase measurements.

7. Step-by-Step Worked Problem: Complete Vibration Isolation Design

Problem: A 350 kg 350\text{ kg} 350 kg motor-driven exhaust fan operates at 1750 rpm 1750\text{ rpm} 1750 rpm and produces a vertical unbalance excitation force F 0 = 800 N F_0 = 800\text{ N} F 0 ​ = 800 N . An engineer must design 4 identical corner spring mounts to achieve 85 % 85\% 85% force isolation ( η iso = 0.85 \eta_{\text{iso}} = 0.85 η iso ​ = 0.85 , T R = 0.15 TR = 0.15 TR = 0.15 ) with negligible damping ( ζ ≈ 0 \zeta \approx 0 ζ ≈ 0 ). Calculate:

Operating excitation frequency f f f and ω \omega ω .

Required frequency ratio r r r .

System natural frequency f n f_n f n ​ in Hz.

Required stiffness of each of the 4 spring mounts.

Static deflection δ s t \delta_{st} δ s t ​ of the mounts.

Dynamic force F T F_T F T ​ transmitted to the supporting floor. +---------------------------------------------------------------------------------------------------+

  • | STEP-BY-STEP SOLUTION WORKFLOW |
  • | |
  • | STEP 1: Excitation Frequencies |
  • | f = 1750 rpm / 60 = 29.167 Hz |
  • | omega = 2 * pi * 29.167 = 183.26 rad/s |
  • | |
  • | STEP 2: Frequency Ratio (r) for TR = 0.15 in Isolation Zone (r > sqrt(2)) |
  • | TR = 1 / (r^2 - 1) ===> 0.15 = 1 / (r^2 - 1) |
  • | r^2 - 1 = 1 / 0.15 = 6.667 ===> r^2 = 7.667 |
  • | r = sqrt(7.667) = 2.7689 |
  • | |
  • | STEP 3: Required Natural Frequency (f_n) |
  • | f_n = f / r = 29.167 Hz / 2.7689 = 10.534 Hz |
  • | omega_n = omega / r = 183.26 / 2.7689 = 66.185 rad/s |
  • | |
  • | STEP 4: Total Spring Stiffness & Stiffness per Mount |
  • | k_total = m * (omega_n)^2 = 350 kg * (66.185 rad/s)^2 = 350 * 4380.5 = 1,533,160 N/m |
  • | k_total = 1.533 MN/m |
  • | For 4 parallel corner mounts: k_each = k_total / 4 = 1,533,160 / 4 = 383,290 N/m |
  • | k_each = 383.3 kN/m |
  • | |
  • | STEP 5: Static Deflection Check |
  • | delta_st = m * g / k_total = (350 * 9.81) / 1,533,160 = 3433.5 / 1,533,160 |
  • | delta_st = 0.002239 m = 2.24 mm |
  • | (Check: f_n = 15.76 / sqrt(2.24 mm) = 15.76 / 1.497 = 10.53 Hz [Matches!]) |
  • | |
  • | STEP 6: Transmitted Dynamic Force (F_T) |
  • | F_T = TR * F_0 = 0.15 * 800 N = 120.0 N |
  • +---------------------------------------------------------------------------------------------------+
  • 8. Exam Tips & Common Traps

Tip

Rapid Isolation Formulas:

For 90 % 90\% 90% isolation ( T R = 0.10 TR = 0.10 TR = 0.10 ): r = 10 + 1 = 11 ≈ 3.32 r = \sqrt{10 + 1} = \sqrt{11} \approx 3.32 r = 10 + 1 ​ = 11 ​ ≈ 3.32 .

For 85 % 85\% 85% isolation ( T R = 0.15 TR = 0.15 TR = 0.15 ): r = 6.67 + 1 = 7.67 ≈ 2.77 r = \sqrt{6.67 + 1} = \sqrt{7.67} \approx 2.77 r = 6.67 + 1 ​ = 7.67 ​ ≈ 2.77 .

For 80 % 80\% 80% isolation ( T R = 0.20 TR = 0.20 TR = 0.20 ): r = 5 + 1 = 6 ≈ 2.45 r = \sqrt{5 + 1} = \sqrt{6} \approx 2.45 r = 5 + 1 ​ = 6 ​ ≈ 2.45 .

Warning

Common Pitfalls:

The Isolation Boundary: Placing mounts such that r < 2 r < \sqrt{2} r < 2 ​ causes force amplification , transmitting higher vibration forces into the floor than if the machine were bolted down rigidly!

Series vs. Parallel Stiffness: Placing identical springs in parallel doubles total stiffness ( 2 k 2k 2 k ), which raises natural frequency and can accidentally push r r r below 2 \sqrt{2} 2 ​ into the amplification zone.