Study guide
4.4 Steady & Transient Conduction, Forced & Natural Convection
PE Mechanical Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Exam Overview, Reference Handbook & Mechanical Engineering Fundamentals
1.1 NCEES PE Mechanical CBT Format, Three Disciplines & Reference Handbook Strategy 1.2 Engineering Economics, Cash Flow & Project Evaluation and Scheduling 1.3 Units, Dimensional Analysis & Physical Constants 1.4 Statics, Dynamics & Mechanical Equilibrium
2 Chapter 2: Mechanical Design & Analysis (Stress, Failure Theories & Components)
2.1 Stress, Strain, Principal Stresses & Combined Loading 2.2 Static Failure Theories for Ductile and Brittle Materials 2.3 Fatigue Analysis, S-N Curves & Fluctuating Stresses 2.4 Pressure Vessels, Column Buckling & Spring Design 2.5 Threaded Fasteners, Welded Connections & Mechanical Joints
3 Chapter 3: Mechanical Power Transmission, Mechanisms & Vibrations
3.1 Shaft Sizing, Torsional Deflection & Critical Speeds 3.2 Spur, Helical, Bevel & Worm Gears and Epicyclic Gear Trains 3.3 Rolling-Element & Journal Bearings, Power Screws, Clutches, Brakes & Flywheels 3.4 Four-Bar Linkages, Cam-Follower Systems & Kinematics 3.5 Single-DOF and 2-DOF Vibrations, Damping & Dynamic Balancing
4 Chapter 4: Thermal & Fluid Systems
4.1 Fluid Statics, Manometry, Submerged Surfaces & Buoyancy 4.2 Incompressible Pipe Flow, Darcy-Weisbach & Minor Losses 4.3 Pump Selection, System Curves, NPSH & Cavitation 4.4 Steady & Transient Conduction, Forced & Natural Convection 4.5 Radiation Heat Transfer, View Factors & Heat Exchanger Sizing (LMTD/NTU)
5 Chapter 5: Power Plants & Energy Conversion Systems
5.1 Thermodynamic Properties, Pure Substances & 1st/2nd Laws 5.2 Vapor Power Cycles (Rankine, Superheat, Reheat & Regeneration) 5.3 Gas Power Cycles (Brayton, Otto, Diesel, Dual & Combined Cycle) 5.4 Combustion Stoichiometry, Flue Gas Analysis & Thermochemistry 5.5 Turbomachinery, Compressible Flow & Nozzles, Renewables & Energy Storage
6 Chapter 6: HVAC & Refrigeration Systems
6.1 Psychrometric Principles & Air-Conditioning Processes 6.2 Cooling & Heating Load Calculations (CLTD/SCL/CLF & Heat Balance) 6.3 Vapor-Compression Refrigeration Cycles & Refrigerant Properties 6.4 Refrigeration Equipment (Compressors, Evaporators, Condensers, Expansion Devices) & Safety Codes 6.5 Air Distribution, Duct Design, Fans & Hydronic Water Networks 6.6 Energy Recovery Devices, HVAC Acoustics & Vibration Isolation
7 Chapter 7: Materials, Manufacturing & Processing
7.1 Ferrous/Non-Ferrous Metals, Polymers, Ceramics & Composites 7.2 Iron-Carbon Equilibrium Phase Diagram & Heat Treatment Processes 7.3 Corrosion, Wear, Creep, Hydrogen Embrittlement & Fracture Mechanics 7.4 Casting, Metal Forming, Forging, Stamping & Powder Metallurgy 7.5 Machining Dynamics, Tool Wear, Welding Metallurgy & Non-Destructive Examination (NDE)
8 Chapter 8: Measurements, Controls, Codes & Engineering Ethics
8.1 Temperature, Pressure, Flow & Strain Transducers and Signal Conditioning 8.2 Feedback Control Loops, PID Tuning, Frequency Response & Stability 8.3 ASME Boiler & Pressure Vessel Code, ASHRAE, OSHA & NFPA Safety Standards 8.4 NCEES Model Rules, Engineering Ethics & Professional Seal Liability
4.4 Steady & Transient Conduction, Forced & Natural Convection
Key Takeaways Explain This Topic AI
One-dimensional steady-state conduction is governed by Fourier's Law q = − k A d T d x q = -k A \frac{dT}{dx} q = − k A d x d T , analyzed using thermal resistance networks ( R plane = L k A R_{\text{plane}} = \frac{L}{k A} R plane = k A L , R cyl = ln ( r 2 / r 1 ) 2 π k L R_{\text{cyl}} = \frac{\ln(r_2/r_1)}{2\pi k L} R cyl = 2 πk L l n ( r 2 / r 1 ) , R conv = 1 h A R_{\text{conv}} = \frac{1}{h A} R conv = h A 1 ).
The critical radius of insulation ( r cr = k h r_{\text{cr}} = \frac{k}{h} r cr = h k for cylinders, 2 k h \frac{2k}{h} h 2 k for spheres) defines the outer radius below which adding insulation increases total heat loss by expanding the external convection surface area.
Extended surfaces (fins) enhance heat transfer if fin effectiveness ϵ f = q f h A c θ b ≥ 2.0 \epsilon_f = \frac{q_f}{h A_c \theta_b} \ge 2.0 ϵ f = h A c θ b q f ≥ 2.0 , evaluated via fin parameter m = h P k A c m = \sqrt{\frac{h P}{k A_c}} m = k A c h P and fin efficiency η f = tanh ( m L c ) m L c \eta_f = \frac{\tanh(m L_c)}{m L_c} η f = m L c t a n h ( m L c ) .
The Lumped Capacitance Method is valid only when the internal thermal resistance is negligible compared to surface convection ( B i = h L c k < 0.1 Bi = \frac{h L_c}{k} < 0.1 B i = k h L c < 0.1 ), yielding exponential transient decay T ( t ) − T ∞ T i − T ∞ = e − t / τ \frac{T(t) - T_\infty}{T_i - T_\infty} = e^{-t / \tau} T i − T ∞ T ( t ) − T ∞ = e − t / τ .
Convection heat transfer coefficients ( h h h ) are resolved from dimensionless correlations relating Nusselt ( N u = h L k Nu = \frac{h L}{k} N u = k h L ), Prandtl ( P r = ν α Pr = \frac{\nu}{\alpha} P r = α ν ), and Reynolds ( R e Re R e ) or Rayleigh ( R a = G r ⋅ P r Ra = Gr \cdot Pr R a = G r ⋅ P r ) numbers.
Last updated: August 2026
Steady & Transient Conduction, Forced & Natural Convection
Thermal energy transport is governed by three fundamental mechanisms: conduction (molecular diffusion across stationary matter), convection (combined conduction and bulk fluid advection), and thermal radiation (electromagnetic wave emission). Mastery of 1D steady-state resistance networks, composite radial insulation sizing, extended surface fin mechanics, transient lumped capacitance response, and forced/natural convection correlations is essential for the NCEES PE Mechanical exam. +---------------------------------------------------------------------------------------------------+
- | HEAT TRANSFER MECHANISMS & GOVERNING LAWS |
- | |
- | [CONDUCTION: FOURIER'S LAW] [CONVECTION: NEWTON'S COOLING] [OVERALL RESISTANCE] |
- | - q = -k * A * (dT/dx) - q = h * A * (T_s - T_\infty) - q = \Delta T / R_total |
- | - R_th = L / (k*A) (Plane) - R_conv = 1 / (h*A) - q = U * A * \Delta T |
- | - R_th = ln(r2/r1)/(2*\pi*k*L) - Nu = h*L / k = f(Re, Pr, Ra) - Critical Radius: k/h |
- | | |
- | v |
- | [TRANSIENT & FINS] |
- | - Lumped Cap: Bi = h*Lc / k < 0.1 |
- | - \theta(t) / \theta_i = exp(-t / \tau) |
- | - Fin Sizing: m = \sqrt{h*P / (k*Ac)} |
- +---------------------------------------------------------------------------------------------------+
- 1. 1D Steady-State Conduction & Thermal Resistance Networks
- Fourier's Law of Heat Conduction
In differential form, Fourier's law states that local heat flux q ′ ′ q'' q ′′ is proportional to the negative temperature gradient: q ′ ′ = q A = − k ∇ T = − k d T d x q'' = \frac{q}{A} = -k \nabla T = -k \frac{dT}{dx} q ′′ = A q = − k ∇ T = − k d x d T
Where:
q = Heat transfer rate ( W or BTU/hr ) q = \text{Heat transfer rate } (\text{W or } \text{BTU/hr}) q = Heat transfer rate ( W or BTU/hr )
k = Thermal conductivity ( W/(m ⋅ K) or BTU/(hr ⋅ ft ⋅ ∘ F) ) k = \text{Thermal conductivity } (\text{W/(m}\cdot\text{K)} \text{ or } \text{BTU/(hr}\cdot\text{ft}\cdot^\circ\text{F)}) k = Thermal conductivity ( W/(m ⋅ K) or BTU/(hr ⋅ ft ⋅ ∘ F) )
A = Cross-sectional heat transfer area perpendicular to heat flow A = \text{Cross-sectional heat transfer area perpendicular to heat flow} A = Cross-sectional heat transfer area perpendicular to heat flow
Thermal Resistance Analogies for Common Geometries
Analogous to Ohm's electrical law ( I = Δ V R I = \frac{\Delta V}{R} I = R Δ V ), thermal heat rate is q = Δ T R th q = \frac{\Delta T}{R_{\text{th}}} q = R th Δ T . +---------------------------------------------------------------------------------------------------+
- | THERMAL RESISTANCE FORMULA SUMMARY |
- | |
- | 1. Plane Wall (Thickness L, Area A): R_{\text{plane}} = \frac{L}{k A} |
- | |
- | 2. Cylindrical Layer (Radii r_1 to r_2, Length L): R_{\text{cyl}} = \frac{\ln(r_2/r_1)}{2 \pi k L} |
- | |
- | 3. Spherical Shell (Radii r_1 to r_2): R_{\text{sph}} = \frac{1/r_1 - 1/r_2}{4 \pi k} |
- | |
- | 4. Convection Boundary (Surface Area A): R_{\text{conv}} = \frac{1}{h A} |
- | |
- | 5. Radiation Boundary (h_r Linearized): R_{\text{rad}} = \frac{1}{h_r A} |
- | where h_r = \epsilon \sigma (T_s + T_{\text{surr}})(T_s^2 + T_{\text{surr}}^2) |
- +---------------------------------------------------------------------------------------------------+
- Composite Cylindrical Pipe with Internal and External Convection
For an insulated industrial pipe carrying hot fluid T ∞ , i T_{\infty,i} T ∞ , i at convection coefficient h i h_i h i , with inner radius r 1 r_1 r 1 , outer pipe radius r 2 r_2 r 2 , outer insulation radius r 3 r_3 r 3 , and ambient air T ∞ , o T_{\infty,o} T ∞ , o at h o h_o h o : +---------------------------------------------------------------------------------------------------+
- | COMPOSITE CYLINDRICAL RESISTANCE CIRCUIT |
- | |
| T_{\infty,i} ---[ R_conv,i ]--- T_1 ---[ R_pipe ]--- T_2 ---[ R_ins ]--- T_3 ---[ R_conv,o ]--- T_{\infty,o} |
- | |
- | R_{\text{total}} = \frac{1}{2\pi r_1 L h_i} + \frac{\ln(r_2/r_1)}{2\pi k_{\text{pipe}} L} |
- | + \frac{\ln(r_3/r_2)}{2\pi k_{\text{ins}} L} + \frac{1}{2\pi r_3 L h_o} |
- | |
| Heat Rate: q = \frac{T_{\infty,i} - T_{\infty,o}}{R_{\text{total}}} = U_o A_o (T_{\infty,i} - T_{\infty,o}) |
- +---------------------------------------------------------------------------------------------------+
- Critical Radius of Insulation
In radial systems, adding insulation increases conduction resistance ( R cond ∝ ln ( r o / r i ) R_{\text{cond}} \propto \ln(r_o/r_i) R cond ∝ ln ( r o / r i ) ) but decreases external convection resistance ( R conv = 1 2 π r o L h R_{\text{conv}} = \frac{1}{2\pi r_o L h} R conv = 2 π r o L h 1 ) due to the expanding surface area. Differentiating total resistance with respect to outer radius r o r_o r o yields the critical radius of insulation ( r cr r_{\text{cr}} r cr ) : r cr, cylinder = k ins h o , r cr, sphere = 2 k ins h o r_{\text{cr, cylinder}} = \frac{k_{\text{ins}}}{h_o}, \quad r_{\text{cr, sphere}} = \frac{2 k_{\text{ins}}}{h_o} r cr, cylinder = h o k ins , r cr, sphere = h o 2 k ins Total Thermal Resistance R_th
- ^
- | R_total = R_cond + R_conv
- | \ /
- | \ /
- | \ /
- | \___ ___/
- | \________/
- | |
- | v Minimum Resistance (Maximum Heat Loss q_max)
- +----------------------(r_cr)---------------------------> Outer Radius r_o
- r_cr = k / h
Important
Critical Radius Sizing Rule:
If initial pipe radius r o < r cr r_o < r_{\text{cr}} r o < r cr : Adding insulation increases heat loss until r = r cr r = r_{\text{cr}} r = r cr , reaching maximum heat dissipation (utilized in cooling electric power cables).
If initial pipe radius r o ≥ r cr r_o \ge r_{\text{cr}} r o ≥ r cr : Adding insulation always decreases heat loss (the standard case for steam and hot water piping insulation design).
2. Extended Surfaces: Fin Heat Transfer
Fins increase convective surface area to enhance heat dissipation from components where the convection heat transfer coefficient h h h is low (e.g., air-cooled engine cylinders, electronics heat sinks). +---------------------------------------------------------------------------------------------------+
- | FIN DIFFERENTIAL EQUATION & PARAMETERS |
- | |
- | Governing ODE: \frac{d^2 \theta}{dx^2} - m^2 \theta = 0 |
- | where \theta(x) = T(x) - T_\infty |
- | |
- | Fin Parameter: m = \sqrt{\frac{h P}{k A_c}} [\text{m}^{-1} \text{ or } \text{ft}^{-1}] |
- | |
- | Fin Characteristic: M = \sqrt{h P k A_c} \theta_b = \sqrt{h P k A_c} (T_b - T_\infty) |
- +---------------------------------------------------------------------------------------------------+
- Fin Tip Boundary Condition Formulations
Tip Boundary Condition Temperature Profile θ ( x ) θ b \frac{\theta(x)}{\theta_b} θ b θ ( x ) Heat Transfer Rate ( q f q_f q f )
1. Infinitely Long Fin ( L → ∞ L \to \infty L → ∞ ) e − m x e^{-m x} e − m x q f = M = h P k A c ( T b − T ∞ ) q_f = M = \sqrt{h P k A_c} (T_b - T_\infty) q f = M = h P k A c ( T b − T ∞ )
2. Adiabatic (Insulated) Tip cosh [ m ( L − x ) ] cosh ( m L ) \frac{\cosh[m(L-x)]}{\cosh(m L)} c o s h ( m L ) c o s h [ m ( L − x )] q f = M tanh ( m L ) q_f = M \tanh(m L) q f = M tanh ( m L )
3. Convective Tip (Corrected Length L c L_c L c ) cosh [ m ( L c − x ) ] cosh ( m L c ) \frac{\cosh[m(L_c-x)]}{\cosh(m L_c)} c o s h ( m L c ) c o s h [ m ( L c − x )] q f ≈ M tanh ( m L c ) q_f \approx M \tanh(m L_c) q f ≈ M tanh ( m L c )
Where corrected fin length L c L_c L c accounts for convective tip area: L c = L + A c P L_c = L + \frac{A_c}{P} L c = L + P A c (for rectangular fin: L c = L + t / 2 L_c = L + t/2 L c = L + t /2 ; for round pin fin: L c = L + D / 4 L_c = L + D/4 L c = L + D /4 ).
Fin Efficiency ( η f \eta_f η f ) and Fin Effectiveness ( ϵ f \epsilon_f ϵ f )
Fin Efficiency ( η f \eta_f η f ): Ratio of actual fin heat transfer to the ideal heat transfer if the entire fin were maintained at base temperature T b T_b T b : η f = q f h A fin θ b = tanh ( m L c ) m L c \eta_f = \frac{q_f}{h A_{\text{fin}} \theta_b} = \frac{\tanh(m L_c)}{m L_c} η f = h A fin θ b q f = m L c tanh ( m L c )
Fin Effectiveness ( ϵ f \epsilon_f ϵ f ): Ratio of fin heat transfer to heat transfer from the bare base area without the fin: ϵ f = q f h A c θ b = η f A fin A c \epsilon_f = \frac{q_f}{h A_c \theta_b} = \frac{\eta_f A_{\text{fin}}}{A_c} ϵ f = h A c θ b q f = A c η f A fin Design Guideline: Fins are economically justified only if ϵ f ≥ 2.0 \epsilon_f \ge 2.0 ϵ f ≥ 2.0 .
3. Transient Conduction & Lumped Capacitance Method
When a solid body at initial temperature T i T_i T i is suddenly exposed to a convective environment at T ∞ T_\infty T ∞ , spatial temperature gradients inside the body may be negligible if conduction resistance is much smaller than external convection resistance. +---------------------------------------------------------------------------------------------------+
- | LUMPED CAPACITANCE CRITERIA & TRANSIENT RESPONSE |
- | |
- | Biot Number Criterion: Bi = \frac{h L_c}{k_{\text{solid}}} < 0.1 |
- | where Characteristic Length L_c = \frac{V_{\text{solid}}}{A_s} |
- | |
- | Temperature Response: \frac{T(t) - T_\infty}{T_i - T_\infty} = \exp\left(-\frac{t}{\tau}\right) |
- | = \exp(-Bi \cdot Fo) |
- | |
- | Thermal Time Constant: \tau = \frac{\rho V c_p}{h A_s} = R_{\text{conv}} C_{\text{thermal}} |
- | |
- | Fourier Number: Fo = \frac{\alpha t}{L_c^2} = \frac{k t}{\rho c_p L_c^2} |
- +---------------------------------------------------------------------------------------------------+
Characteristic Lengths ( L c = V / A s L_c = V / A_s L c = V / A s ):
Plane Wall of thickness 2 L 2L 2 L (exposed both sides): L c = L L_c = L L c = L
Long Solid Cylinder of radius r o r_o r o : L c = π r o 2 L 2 π r o L = r o 2 L_c = \frac{\pi r_o^2 L}{2\pi r_o L} = \frac{r_o}{2} L c = 2 π r o L π r o 2 L = 2 r o
Solid Sphere of radius r o r_o r o : L c = 4 3 π r o 3 4 π r o 2 = r o 3 L_c = \frac{\frac{4}{3}\pi r_o^3}{4\pi r_o^2} = \frac{r_o}{3} L c = 4 π r o 2 3 4 π r o 3 = 3 r o
Total Energy Transfer ( Q total Q_{\text{total}} Q total ) over time t t t : Q ( t ) = ρ V c p ( T i − T ∞ ) [ 1 − exp ( − t τ ) ] Q(t) = \rho V c_p (T_i - T_\infty) \left[ 1 - \exp\left(-\frac{t}{\tau}\right) \right] Q ( t ) = ρ V c p ( T i − T ∞ ) [ 1 − exp ( − τ t ) ]
Warning
Biot Number Thermal Conductivity Trap: In B i = h L c k Bi = \frac{h L_c}{k} B i = k h L c , the thermal conductivity k k k is that of the solid material , NOT the surrounding fluid! Conversely, in the Nusselt number N u = h L k f Nu = \frac{h L}{k_f} N u = k f h L , k f k_f k f is the thermal conductivity of the fluid .
4. Forced Convection Correlations
Convection heat transfer coefficients ( h h h ) are correlated through dimensionless parameters: N u = h L k f , R e = V L ν , P r = ν α = μ c p k f Nu = \frac{h L}{k_f}, \quad Re = \frac{V L}{\nu}, \quad Pr = \frac{\nu}{\alpha} = \frac{\mu c_p}{k_f} N u = k f h L , R e = ν V L , P r = α ν = k f μ c p +---------------------------------------------------------------------------------------------------+
- | INTERNAL FORCED FLOW IN CIRCULAR TUBES |
- | |
- | 1. FULLY DEVELOPED LAMINAR FLOW (Re_D < 2300): |
- | - Uniform Surface Heat Flux (q" = const): Nu_D = \frac{h D}{k_f} = 4.36 |
- | - Constant Surface Temperature (T_s = const): Nu_D = \frac{h D}{k_f} = 3.66 |
- | |
- | 2. FULLY DEVELOPED TURBULENT FLOW (Re_D > 10,000, 0.6 <= Pr <= 160): |
- | Dittus-Boelter Equation: |
- | Nu_D = 0.023 \, Re_D^{0.8} \, Pr^n |
- | - n = 0.4 for fluid HEATING (T_s > T_b) |
- | - n = 0.3 for fluid COOLING (T_s < T_b) |
- | (All fluid properties evaluated at mean bulk temperature T_b = (T_{in} + T_{out})/2) |
- +---------------------------------------------------------------------------------------------------+
- External Forced Flow Over Flat Plates
Laminar Boundary Layer ( R e x < 5 × 10 5 Re_x < 5 \times 10^5 R e x < 5 × 1 0 5 ): N u x = 0.332 R e x 1 / 2 P r 1 / 3 , N u ‾ L = 0.664 R e L 1 / 2 P r 1 / 3 Nu_x = 0.332 \, Re_x^{1/2} Pr^{1/3}, \quad \overline{Nu}_L = 0.664 \, Re_L^{1/2} Pr^{1/3} N u x = 0.332 R e x 1/2 P r 1/3 , N u L = 0.664 R e L 1/2 P r 1/3
Turbulent Boundary Layer ( R e x ≥ 5 × 10 5 Re_x \ge 5 \times 10^5 R e x ≥ 5 × 1 0 5 ): N u x = 0.0296 R e x 0.8 P r 1 / 3 Nu_x = 0.0296 \, Re_x^{0.8} Pr^{1/3} N u x = 0.0296 R e x 0.8 P r 1/3 (Properties evaluated at film temperature T f = T s + T ∞ 2 T_f = \frac{T_s + T_\infty}{2} T f = 2 T s + T ∞ )
5. Natural (Free) Convection Correlations
In natural convection, fluid motion is driven entirely by buoyancy forces resulting from temperature-induced density gradients. +---------------------------------------------------------------------------------------------------+
- | NATURAL CONVECTION DIMENSIONLESS GROUPS |
- | |
- | Grashof Number: Gr_L = \frac{g \beta (T_s - T_\infty) L^3}{\nu^2} |
- | |
- | Rayleigh Number: Ra_L = Gr_L \cdot Pr = \frac{g \beta (T_s - T_\infty) L^3}{\nu \alpha} |
- | |
- | Ideal Gas Expansivity: \beta = \frac{1}{T_f} [T_f \text{ in absolute units: Kelvin or Rankine}]|
- +---------------------------------------------------------------------------------------------------+
Empirical Correlations for Vertical Plates ( L = Height L = \text{Height} L = Height ):
Laminar Regime ( 10 4 ≤ R a L ≤ 10 9 10^4 \le Ra_L \le 10^9 1 0 4 ≤ R a L ≤ 1 0 9 ): N u ‾ L = 0.59 R a L 1 / 4 \overline{Nu}_L = 0.59 \, Ra_L^{1/4} N u L = 0.59 R a L 1/4
Turbulent Regime ( 10 9 ≤ R a L ≤ 10 13 10^9 \le Ra_L \le 10^{13} 1 0 9 ≤ R a L ≤ 1 0 13 ): N u ‾ L = 0.10 R a L 1 / 3 \overline{Nu}_L = 0.10 \, Ra_L^{1/3} N u L = 0.10 R a L 1/3
Natural vs. Forced Convection Regimes:
G r R e 2 ≪ 1 \frac{Gr}{Re^2} \ll 1 R e 2 G r ≪ 1 : Forced convection dominates (natural convection neglected).
G r R e 2 ≫ 1 \frac{Gr}{Re^2} \gg 1 R e 2 G r ≫ 1 : Natural convection dominates (forced convection neglected).
G r R e 2 ≈ 1 \frac{Gr}{Re^2} \approx 1 R e 2 G r ≈ 1 : Mixed convection (both mechanisms significant).
- 6. Step-by-Step Worked Engineering Problem
- Problem Statement
A Schedule 40 carbon steel steam pipe ( k p = 45 W/m ⋅ K k_p = 45\text{ W/m}\cdot\text{K} k p = 45 W/m ⋅ K ) with outer diameter D o = 100 mm D_o = 100\text{ mm} D o = 100 mm ( r 1 = 50 mm = 0.050 m r_1 = 50\text{ mm} = 0.050\text{ m} r 1 = 50 mm = 0.050 m ) transports dry steam at T ∞ , i = 220 ∘ C T_{\infty,i} = 220^\circ\text{C} T ∞ , i = 22 0 ∘ C with internal convection coefficient h i = 1200 W/m 2 ⋅ K h_i = 1200\text{ W/m}^2\cdot\text{K} h i = 1200 W/m 2 ⋅ K . The pipe is insulated with a layer of fiberglass insulation ( k ins = 0.040 W/m ⋅ K k_{\text{ins}} = 0.040\text{ W/m}\cdot\text{K} k ins = 0.040 W/m ⋅ K ) of thickness t ins = 50 mm t_{\text{ins}} = 50\text{ mm} t ins = 50 mm ( r 2 = 0.100 m r_2 = 0.100\text{ m} r 2 = 0.100 m ). The outside ambient air is at T ∞ , o = 20 ∘ C T_{\infty,o} = 20^\circ\text{C} T ∞ , o = 2 0 ∘ C with external convection coefficient h o = 10 W/m 2 ⋅ K h_o = 10\text{ W/m}^2\cdot\text{K} h o = 10 W/m 2 ⋅ K . Neglect pipe wall thickness (assume r pipe = r 1 r_{\text{pipe}} = r_1 r pipe = r 1 ).
Determine:
The critical radius of insulation r cr r_{\text{cr}} r cr .
The total thermal resistance per unit length R total ′ R'_{\text{total}} R total ′ ( K ⋅ m/W \text{K}\cdot\text{m/W} K ⋅ m/W ).
The heat loss rate per meter of pipe length q ′ q' q ′ .
The outer surface temperature of the insulation T s , o T_{s,o} T s , o .
Step-by-Step Solution
Step 1: Check Critical Radius of Insulation r cr = k ins h o = 0.040 W/m ⋅ K 10 W/m 2 ⋅ K = 0.004 m = 4.0 mm r_{\text{cr}} = \frac{k_{\text{ins}}}{h_o} = \frac{0.040\text{ W/m}\cdot\text{K}}{10\text{ W/m}^2\cdot\text{K}} = 0.004\text{ m} = 4.0\text{ mm} r cr = h o k ins = 10 W/m 2 ⋅ K 0.040 W/m ⋅ K = 0.004 m = 4.0 mm
Because the bare pipe outer radius r 1 = 50 mm ≫ r cr = 4.0 mm r_1 = 50\text{ mm} \gg r_{\text{cr}} = 4.0\text{ mm} r 1 = 50 mm ≫ r cr = 4.0 mm , adding insulation is guaranteed to substantially reduce heat loss.
Step 2: Calculate Individual Thermal Resistances per Unit Length ( L = 1.0 m L = 1.0\text{ m} L = 1.0 m )
Internal convection resistance: R conv , i ′ = 1 2 π r 1 h i = 1 2 π ( 0.050 m ) ( 1200 W/m 2 ⋅ K ) = 1 376.99 = 0.00265 K ⋅ m/W R'_{\text{conv},i} = \frac{1}{2\pi r_1 h_i} = \frac{1}{2\pi (0.050\text{ m}) (1200\text{ W/m}^2\cdot\text{K})} = \frac{1}{376.99} = 0.00265\text{ K}\cdot\text{m/W} R conv , i ′ = 2 π r 1 h i 1 = 2 π ( 0.050 m ) ( 1200 W/m 2 ⋅ K ) 1 = 376.99 1 = 0.00265 K ⋅ m/W
Insulation conduction resistance: R ins ′ = ln ( r 2 / r 1 ) 2 π k ins = ln ( 0.100 / 0.050 ) 2 π ( 0.040 W/m ⋅ K ) = ln ( 2.0 ) 0.25133 = 0.69315 0.25133 = 2.7577 K ⋅ m/W R'_{\text{ins}} = \frac{\ln(r_2/r_1)}{2\pi k_{\text{ins}}} = \frac{\ln(0.100 / 0.050)}{2\pi (0.040\text{ W/m}\cdot\text{K})} = \frac{\ln(2.0)}{0.25133} = \frac{0.69315}{0.25133} = 2.7577\text{ K}\cdot\text{m/W} R ins ′ = 2 π k ins ln ( r 2 / r 1 ) = 2 π ( 0.040 W/m ⋅ K ) ln ( 0.100/0.050 ) = 0.25133 ln ( 2.0 ) = 0.25133 0.69315 = 2.7577 K ⋅ m/W
External convection resistance: R conv , o ′ = 1 2 π r 2 h o = 1 2 π ( 0.100 m ) ( 10 W/m 2 ⋅ K ) = 1 6.2832 = 0.15915 K ⋅ m/W R'_{\text{conv},o} = \frac{1}{2\pi r_2 h_o} = \frac{1}{2\pi (0.100\text{ m}) (10\text{ W/m}^2\cdot\text{K})} = \frac{1}{6.2832} = 0.15915\text{ K}\cdot\text{m/W} R conv , o ′ = 2 π r 2 h o 1 = 2 π ( 0.100 m ) ( 10 W/m 2 ⋅ K ) 1 = 6.2832 1 = 0.15915 K ⋅ m/W
Total thermal resistance: R total ′ = R conv , i ′ + R ins ′ + R conv , o ′ = 0.00265 + 2.7577 + 0.15915 = 2.9195 K ⋅ m/W R'_{\text{total}} = R'_{\text{conv},i} + R'_{\text{ins}} + R'_{\text{conv},o} = 0.00265 + 2.7577 + 0.15915 = 2.9195\text{ K}\cdot\text{m/W} R total ′ = R conv , i ′ + R ins ′ + R conv , o ′ = 0.00265 + 2.7577 + 0.15915 = 2.9195 K ⋅ m/W
Step 3: Calculate Heat Loss per Unit Length ( q ′ q' q ′ ) q ′ = T ∞ , i − T ∞ , o R total ′ = 220 ∘ C − 20 ∘ C 2.9195 K ⋅ m/W = 200 K 2.9195 = 68.51 W/m q' = \frac{T_{\infty,i} - T_{\infty,o}}{R'_{\text{total}}} = \frac{220^\circ\text{C} - 20^\circ\text{C}}{2.9195\text{ K}\cdot\text{m/W}} = \frac{200\text{ K}}{2.9195} = 68.51\text{ W/m} q ′ = R total ′ T ∞ , i − T ∞ , o = 2.9195 K ⋅ m/W 22 0 ∘ C − 2 0 ∘ C = 2.9195 200 K = 68.51 W/m
Step 4: Calculate Outer Surface Temperature of Insulation ( T s , o T_{s,o} T s , o ) Using the external convection link: q ′ = T s , o − T ∞ , o R conv , o ′ q' = \frac{T_{s,o} - T_{\infty,o}}{R'_{\text{conv},o}} q ′ = R conv , o ′ T s , o − T ∞ , o : T s , o = T ∞ , o + q ′ R conv , o ′ = 20 ∘ C + ( 68.51 W/m × 0.15915 K ⋅ m/W ) = 20 + 10.90 = 30.9 ∘ C T_{s,o} = T_{\infty,o} + q' R'_{\text{conv},o} = 20^\circ\text{C} + (68.51\text{ W/m} \times 0.15915\text{ K}\cdot\text{m/W}) = 20 + 10.90 = 30.9^\circ\text{C} T s , o = T ∞ , o + q ′ R conv , o ′ = 2 0 ∘ C + ( 68.51 W/m × 0.15915 K ⋅ m/W ) = 20 + 10.90 = 30. 9 ∘ C
- (Safe touch temperature for personnel protection)
- 7. Common Exam Traps & PE Pro-Tips
Tip
Exponent Rule in Dittus-Boelter Correlation: In N u = 0.023 R e 0.8 P r n Nu = 0.023 Re^{0.8} Pr^n N u = 0.023 R e 0.8 P r n , remember the mnemonic: n = 0.4 n = 0.4 n = 0.4 for warming (heating) and n = 0.3 n = 0.3 n = 0.3 for chilling (cooling) of the fluid. The exponent is always applied to the Prandtl number ( P r Pr P r ), never the Reynolds number.
Warning
Common Traps to Avoid:
Trap 1 — Film Temperature Evaluation in Free Convection: When evaluating fluid properties for Grashof and Rayleigh numbers, you must evaluate properties at the film temperature T f = ( T s + T ∞ ) / 2 T_f = (T_s + T_\infty)/2 T f = ( T s + T ∞ ) /2 . Furthermore, β = 1 / T f \beta = 1/T_f β = 1/ T f requires T f T_f T f in Kelvin (or Rankine) , never Celsius!
Trap 2 — Log Mean vs. Arithmetic Mean in Conduction: For cylindrical shells, never use arithmetic mean radius ( r 1 + r 2 ) / 2 (r_1+r_2)/2 ( r 1 + r 2 ) /2 in plane wall formulas when r 2 / r 1 > 1.1 r_2/r_1 > 1.1 r 2 / r 1 > 1.1 . You must use the exact logarithmic resistance R cyl = ln ( r 2 / r 1 ) 2 π k L R_{\text{cyl}} = \frac{\ln(r_2/r_1)}{2\pi k L} R cyl = 2 πk L l n ( r 2 / r 1 ) .