Study guide
4.3 Pump Selection, System Curves, NPSH & Cavitation
PE Mechanical Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Exam Overview, Reference Handbook & Mechanical Engineering Fundamentals
1.1 NCEES PE Mechanical CBT Format, Three Disciplines & Reference Handbook Strategy 1.2 Engineering Economics, Cash Flow & Project Evaluation and Scheduling 1.3 Units, Dimensional Analysis & Physical Constants 1.4 Statics, Dynamics & Mechanical Equilibrium
2 Chapter 2: Mechanical Design & Analysis (Stress, Failure Theories & Components)
2.1 Stress, Strain, Principal Stresses & Combined Loading 2.2 Static Failure Theories for Ductile and Brittle Materials 2.3 Fatigue Analysis, S-N Curves & Fluctuating Stresses 2.4 Pressure Vessels, Column Buckling & Spring Design 2.5 Threaded Fasteners, Welded Connections & Mechanical Joints
3 Chapter 3: Mechanical Power Transmission, Mechanisms & Vibrations
3.1 Shaft Sizing, Torsional Deflection & Critical Speeds 3.2 Spur, Helical, Bevel & Worm Gears and Epicyclic Gear Trains 3.3 Rolling-Element & Journal Bearings, Power Screws, Clutches, Brakes & Flywheels 3.4 Four-Bar Linkages, Cam-Follower Systems & Kinematics 3.5 Single-DOF and 2-DOF Vibrations, Damping & Dynamic Balancing
4 Chapter 4: Thermal & Fluid Systems
4.1 Fluid Statics, Manometry, Submerged Surfaces & Buoyancy 4.2 Incompressible Pipe Flow, Darcy-Weisbach & Minor Losses 4.3 Pump Selection, System Curves, NPSH & Cavitation 4.4 Steady & Transient Conduction, Forced & Natural Convection 4.5 Radiation Heat Transfer, View Factors & Heat Exchanger Sizing (LMTD/NTU)
5 Chapter 5: Power Plants & Energy Conversion Systems
5.1 Thermodynamic Properties, Pure Substances & 1st/2nd Laws 5.2 Vapor Power Cycles (Rankine, Superheat, Reheat & Regeneration) 5.3 Gas Power Cycles (Brayton, Otto, Diesel, Dual & Combined Cycle) 5.4 Combustion Stoichiometry, Flue Gas Analysis & Thermochemistry 5.5 Turbomachinery, Compressible Flow & Nozzles, Renewables & Energy Storage
6 Chapter 6: HVAC & Refrigeration Systems
6.1 Psychrometric Principles & Air-Conditioning Processes 6.2 Cooling & Heating Load Calculations (CLTD/SCL/CLF & Heat Balance) 6.3 Vapor-Compression Refrigeration Cycles & Refrigerant Properties 6.4 Refrigeration Equipment (Compressors, Evaporators, Condensers, Expansion Devices) & Safety Codes 6.5 Air Distribution, Duct Design, Fans & Hydronic Water Networks 6.6 Energy Recovery Devices, HVAC Acoustics & Vibration Isolation
7 Chapter 7: Materials, Manufacturing & Processing
7.1 Ferrous/Non-Ferrous Metals, Polymers, Ceramics & Composites 7.2 Iron-Carbon Equilibrium Phase Diagram & Heat Treatment Processes 7.3 Corrosion, Wear, Creep, Hydrogen Embrittlement & Fracture Mechanics 7.4 Casting, Metal Forming, Forging, Stamping & Powder Metallurgy 7.5 Machining Dynamics, Tool Wear, Welding Metallurgy & Non-Destructive Examination (NDE)
8 Chapter 8: Measurements, Controls, Codes & Engineering Ethics
8.1 Temperature, Pressure, Flow & Strain Transducers and Signal Conditioning 8.2 Feedback Control Loops, PID Tuning, Frequency Response & Stability 8.3 ASME Boiler & Pressure Vessel Code, ASHRAE, OSHA & NFPA Safety Standards 8.4 NCEES Model Rules, Engineering Ethics & Professional Seal Liability
4.3 Pump Selection, System Curves, NPSH & Cavitation
Key Takeaways Explain This Topic AI
A pump's operating point is established at the exact intersection of the pump manufacturer head curve ( H pump ( Q ) H_{\text{pump}}(Q) H pump ( Q ) ) and the system head curve ( H sys ( Q ) = H static + k Q 2 H_{\text{sys}}(Q) = H_{\text{static}} + k Q^2 H sys ( Q ) = H static + k Q 2 ).
Pump Affinity Laws dictate that for speed variations ( N N N ), flow scales linearly ( Q ∝ N Q \propto N Q ∝ N ), head scales quadratically ( H ∝ N 2 H \propto N^2 H ∝ N 2 ), and brake horsepower scales cubically ( P ∝ N 3 P \propto N^3 P ∝ N 3 ).
In series configurations, pump heads add at constant flow ( H total = H 1 + H 2 H_{\text{total}} = H_1 + H_2 H total = H 1 + H 2 ), whereas in parallel configurations, flows add at constant head ( Q total = Q 1 + Q 2 Q_{\text{total}} = Q_1 + Q_2 Q total = Q 1 + Q 2 ).
Specific speed N s = N Q H 3 / 4 N_s = \frac{N \sqrt{Q}}{H^{3/4}} N s = H 3/4 N Q dictates impeller geometry, progressing from radial flow (low N s N_s N s , high head) to mixed flow, to axial propeller flow (high N s N_s N s , high flow, low head).
To prevent destructive cavitation, Net Positive Suction Head Available ( N P S H A = p 0 − p v γ ± z s − h f s NPSHA = \frac{p_0 - p_v}{\gamma} \pm z_s - h_{fs} NPS H A = γ p 0 − p v ± z s − h f s ) must exceed Net Positive Suction Head Required ( N P S H R NPSHR NPS H R ) with a safe engineering margin.
Last updated: August 2026
Pump Selection, System Curves, NPSH & Cavitation
Pumps add mechanical energy to fluids to overcome elevation differences, maintain pressure boundaries, and balance frictional head losses in piping networks. For mechanical engineers, sizing a pump requires analyzing pump performance and system curves , applying affinity laws for variable-speed drives (VFDs) , selecting impellers via specific speed ( N s N_s N s ) , and conducting rigorous Net Positive Suction Head (NPSH) calculations to prevent destructive cavitation. +---------------------------------------------------------------------------------------------------+
- | PUMP & PIPING SYSTEM INTERACTION MATRIX |
- | |
- | [PUMP PERFORMANCE CURVES] [SYSTEM HEAD CURVE] [OPERATING POINT MATCH] |
- | - H_pump vs Q (Manufacturer) - H_sys = H_static + k*Q^2 - Intersection: H_pump = H_sys |
- | - Efficiency \eta vs Q - Static Lift: \Delta z, \Delta P - Best Efficiency Point (BEP)|
- | - BHP = \gamma*Q*H / (550*\eta) - Dynamic Friction: k*Q^2 - Series / Parallel Balancing |
- | | |
- | v |
- | [CAVITATION GUARD] |
- | - NPSHA = (p0 - pv)/\gamma +/- zs - h_fs |
- | - Design Requirement: NPSHA >= NPSHR + Margin |
- +---------------------------------------------------------------------------------------------------+
1. Pump Classifications: Dynamic vs. Positive Displacement +---------------------------------------------------------------------------------------------------+
- | PUMP CLASSIFICATION TAXONOMY |
- | |
- | 1. DYNAMIC (TURBOMACHINERY): |
- | - Centrifugal (Radial Flow): High head, moderate flow (fluid enters axially, exits radially) |
- | - Mixed Flow: Medium head, medium flow (combined radial/axial discharge) |
- | - Axial Flow (Propeller): Low head (< 30 ft), high flow (> 10,000 gpm) |
- | |
- | 2. POSITIVE DISPLACEMENT (PD): |
- | - Reciprocating: Piston, Plunger, Diaphragm (High pressure, pulsating, constant volume) |
- | - Rotary: Gear, Screw, Lobe, Vane (Viscous oils, constant non-pulsating discharge) |
- | - Key Feature: Delivers constant flow regardless of discharge head; requires PRVs! |
- +---------------------------------------------------------------------------------------------------+
Power & Efficiency Formulations +---------------------------------------------------------------------------------------------------+
- | PUMP POWER CALCULATION FORMULAS |
- | |
- | US CUSTOMARY UNITS: |
- | - Water Horsepower (Hydraulic Power): WHP = \frac{Q (\text{gpm}) \times H (\text{ft}) \times SG}{3960} |
| - Brake Horsepower (Shaft Power): BHP = \frac{WHP}{\eta_{\text{pump}}} = \frac{Q \times H \times SG}{3960 \times \eta_{\text{pump}}} |
| - Motor Input Electrical Power: P_{\text{in}} = \frac{BHP \times 0.7457}{\eta_{\text{motor}}} \; [\text{kW}] |
- | |
- | SI METRIC UNITS: |
- | - Hydraulic Power: P_{\text{hyd}} = \rho g Q H = \gamma Q H [\text{Watts}]|
- | - Brake Power: P_{\text{brake}} = \frac{\rho g Q H}{\eta_{\text{pump}}} [\text{Watts}] |
- +---------------------------------------------------------------------------------------------------+
Note
Derivation of 3960 Constant: In US Customary units: 1 gpm = 1 448.83 cfs 1\text{ gpm} = \frac{1}{448.83}\text{ cfs} 1 gpm = 448.83 1 cfs , γ water = 62.43 lbf/ft 3 \gamma_{\text{water}} = 62.43\text{ lbf/ft}^3 γ water = 62.43 lbf/ft 3 , and 1 hp = 550 ft ⋅ lbf/s 1\text{ hp} = 550\text{ ft}\cdot\text{lbf/s} 1 hp = 550 ft ⋅ lbf/s . Power (hp) = Q ( gpm ) × 1 448.83 ft 3 / s × 62.43 S G lbf/ft 3 × H ( ft ) 550 ft ⋅ lbf/s = Q × H × S G 3960 \text{Power (hp)} = \frac{Q (\text{gpm}) \times \frac{1}{448.83}\text{ ft}^3/\text{s} \times 62.43 SG \text{ lbf/ft}^3 \times H (\text{ft})}{550\text{ ft}\cdot\text{lbf/s}} = \frac{Q \times H \times SG}{3960} Power (hp) = 550 ft ⋅ lbf/s Q ( gpm ) × 448.83 1 ft 3 / s × 62.43 SG lbf/ft 3 × H ( ft ) = 3960 Q × H × SG
2. System Head Curves and Operating Point Determination
The total dynamic head ( H sys H_{\text{sys}} H sys ) required by a piping network is partitioned into static head ( H static H_{\text{static}} H static ) and dynamic friction head ( H dynamic H_{\text{dynamic}} H dynamic ): H sys ( Q ) = H static + H dynamic = ( z 2 − z 1 + p 2 − p 1 γ ) + k Q 2 H_{\text{sys}}(Q) = H_{\text{static}} + H_{\text{dynamic}} = \left( z_2 - z_1 + \frac{p_2 - p_1}{\gamma} \right) + k Q^2 H sys ( Q ) = H static + H dynamic = ( z 2 − z 1 + γ p 2 − p 1 ) + k Q 2
Where:
H static = ( z 2 − z 1 ) + p 2 − p 1 γ H_{\text{static}} = (z_2 - z_1) + \frac{p_2 - p_1}{\gamma} H static = ( z 2 − z 1 ) + γ p 2 − p 1 is independent of flow rate Q Q Q .
k = 8 π 2 g D 4 ( f L D + ∑ K ) k = \frac{8}{\pi^2 g D^4} \left( f \frac{L}{D} + \sum K \right) k = π 2 g D 4 8 ( f D L + ∑ K ) is the network hydraulic resistance constant. Head (H)
- ^
- | Pump Characteristic: H_pump(Q)
- | H_0 +---------------------\
- | | \\
- | | \\ OPERATING POINT
- | H_op|--------------------------(•) [Q_op, H_op]
- | | / \\
- | | / \\
- | | / \\
- | H_st+ / \\
- | | System Curve: / \\
- | | H_sys = H_st + kQ^2 \\
- +------+--------------------+-------------------> Flow Rate (Q)
- 0 Q_op
- Series and Parallel Pump Combinations
Pumps in Series (High Head):
Flow rate through each pump is identical: Q total = Q 1 = Q 2 Q_{\text{total}} = Q_1 = Q_2 Q total = Q 1 = Q 2 .
Combined head is the vertical sum of individual heads: H total ( Q ) = H 1 ( Q ) + H 2 ( Q ) H_{\text{total}}(Q) = H_1(Q) + H_2(Q) H total ( Q ) = H 1 ( Q ) + H 2 ( Q ) .
Used when piping system resistance exhibits steep static lift or extreme friction.
Pumps in Parallel (High Flow):
Head produced across each branch is identical: H total = H 1 = H 2 H_{\text{total}} = H_1 = H_2 H total = H 1 = H 2 .
Combined flow is the horizontal sum of individual flows: Q total ( H ) = Q 1 ( H ) + Q 2 ( H ) Q_{\text{total}}(H) = Q_1(H) + Q_2(H) Q total ( H ) = Q 1 ( H ) + Q 2 ( H ) .
Used in flat system curves where high volumetric throughput is required. +---------------------------------------------------------------------------------------------------+
- | SERIES VS. PARALLEL COMBINATIONS |
- | |
- | SERIES (Add Heads vertically at given Q): PARALLEL (Add Flows horizontally at given H): |
- | Head H Head H |
- | ^ ^ |
- | | Combined (H_1 + H_2) | |
- | | /\ | Pump 1 Combined (Q_1 + Q_2) |
- | | / \ | \ \ |
- | | Pump 1 \ |--------+------------+---- |
- | | \ \ | | | |
- | +--------+------+----> Flow Q +--------+------------+----> Flow Q |
- | Q_1 Q_1 Q_total |
- +---------------------------------------------------------------------------------------------------+
- 3. Pump Affinity Laws
The Affinity Laws describe how centrifugal pump performance scales when rotational speed ( N N N ) or impeller diameter ( D D D ) is altered: +---------------------------------------------------------------------------------------------------+
- | PUMP AFFINITY LAWS |
- | |
- | SPEED VARIATION (Constant Impeller Diameter D_1 = D_2): |
- | $$\frac{Q_2}{Q_1} = \frac{N_2}{N_1}$$ |
- | $$\frac{H_2}{H_1} = \left( \frac{N_2}{N_1} \right)^2$$ |
- | $$\frac{P_2}{P_1} = \left( \frac{N_2}{N_1} \right)^3$$ |
- | |
- | DIAMETER VARIATION (Constant Rotational Speed N_1 = N_2, Small Trims < 15%): |
- | $$\frac{Q_2}{Q_1} = \frac{D_2}{D_1}$$ |
- | $$\frac{H_2}{H_1} = \left( \frac{D_2}{D_1} \right)^2$$ |
- | $$\frac{P_2}{P_1} = \left( \frac{D_2}{D_1} \right)^3$$ |
- | |
- | COMBINED VARIATION: |
- | $$\frac{Q_2}{Q_1} = \left(\frac{N_2}{N_1}\right)\left(\frac{D_2}{D_1}\right), \quad |
- | \frac{H_2}{H_1} = \left(\frac{N_2}{N_1}\right)^2\left(\frac{D_2}{D_1}\right)^2, \quad |
- | \frac{P_2}{P_1} = \left(\frac{N_2}{N_1}\right)^3\left(\frac{D_2}{D_1}\right)^3$$ |
- +---------------------------------------------------------------------------------------------------+
Warning
Affinity Law Exam Trap on Static Head Systems: Affinity laws track the locus of points at constant efficiency along parabolas H ∝ Q 2 H \propto Q^2 H ∝ Q 2 originating from ( 0 , 0 ) (0,0) ( 0 , 0 ) . When a pump is throttled via VFD in a system with high static head ( H static > 0 H_{\text{static}} > 0 H static > 0 ) , the new operating point does not follow Q 2 / Q 1 = N 2 / N 1 Q_2/Q_1 = N_2/N_1 Q 2 / Q 1 = N 2 / N 1 directly. You must transform the pump curve points via affinity laws and find the new intersection with H sys = H static + k Q 2 H_{\text{sys}} = H_{\text{static}} + k Q^2 H sys = H static + k Q 2 .
4. Specific Speed and Impeller Classification
Specific Speed ( N s N_s N s ) is a dimensionless (or standardized dimensional) index that characterizes the geometric shape of a pump impeller at its Best Efficiency Point (BEP): N s = N Q H 3 / 4 N_s = \frac{N \sqrt{Q}}{H^{3/4}} N s = H 3/4 N Q
Where (in US Customary engineering conventions): N = Speed (rpm) N = \text{Speed (rpm)} N = Speed (rpm) , Q = Flow at BEP (gpm) Q = \text{Flow at BEP (gpm)} Q = Flow at BEP (gpm) , H = Head per stage at BEP (ft) H = \text{Head per stage at BEP (ft)} H = Head per stage at BEP (ft) .
- Impeller Type Specific Speed Range ( N s N_s N s , US) Flow Geometry Head vs. Flow Characteristic
- Radial Vane (Centrifugal) 500 − 1500 500 - 1500 500 − 1500 Pure Radial discharge High head, low flow rate
- Francis Vane 1500 − 4000 1500 - 4000 1500 − 4000 Radial-to-axial turn Moderate-to-high head, medium flow
- Mixed Flow 4000 − 9000 4000 - 9000 4000 − 9000 Diagonal discharge Medium head, high flow rate
Axial Flow (Propeller) 9000 − 15000 + 9000 - 15000+ 9000 − 15000 + Pure Axial flow Low head ( < 30 ft < 30\text{ ft} < 30 ft ), extreme flow +---------------------------------------------------------------------------------------------------+
- | SUCTION SPECIFIC SPEED (N_ss) & RECIRCULATION |
- | |
- | Formula: N_{ss} = \frac{N \sqrt{Q}}{(NPSHR)^{3/4}} |
- | |
- | - Industry Standard (Hydraulic Institute): Safe N_ss is typically 8,500 to 11,000. |
- | - N_ss > 12,000: Extreme risk of suction recirculation, cavitation surges, and shaft fatigue. |
- +---------------------------------------------------------------------------------------------------+
- 5. Cavitation Mechanics and Net Positive Suction Head (NPSH)
- The Physics of Cavitation Damage
Cavitation occurs when the local static pressure inside the pump suction eye drops below the liquid's saturation vapor pressure ( p < p v p < p_v p < p v at the operating temperature). Vapor cavities (bubbles) nucleate instantly. As these vapor bubbles travel into regions of higher pressure along the impeller vanes, they implode violently within microseconds , generating microscopic liquid micro-jets with localized impact pressures exceeding 1000 MPa 1000\text{ MPa} 1000 MPa ( 150 , 000 psi 150,000\text{ psi} 150 , 000 psi ). This causes pitting erosion, structural vibration, acoustic rattling ("pumping gravel"), and sudden collapse of pump head and efficiency. +---------------------------------------------------------------------------------------------------+
- | NET POSITIVE SUCTION HEAD (NPSH) DEFINITIONS |
- | |
- | 1. NPSHA (Available): Determined strictly by the suction piping geometry, elevations, and fluid |
- | NPSHA = \frac{p_{s,\text{total}}}{\gamma} - \frac{p_v}{\gamma} |
- | = \frac{p_0}{\gamma} \pm z_s - h_{fs} - \frac{p_v}{\gamma} |
- | |
- | 2. NPSHR (Required): Determined strictly by the pump manufacturer via testing (3% head drop) |
- | |
- | 3. CAVITATION AVOIDANCE CRITERION: |
- | NPSHA >= NPSHR + NPSH_{\text{margin}} (Typical margin: 3 to 5 ft or 1.10 to 1.25 * NPSHR) |
+---------------------------------------------------------------------------------------------------+ Suction Tank
- |~~~| Liquid surface at pressure p_0 (e.g., p_atm)
- +---+
- |
- | +z_s (Flooded Suction: Tank above pump)
- | -z_s (Suction Lift: Tank below pump)
- v
- [ PUMP ] <--- Suction eye where p_min occurs
- | h_fs = Suction line friction + entrance + valve head losses
- +---------> p_v = Vapor pressure of liquid at operating temperature
Detailed Variable Definitions for NPSHA Calculation:
p 0 = Absolute pressure on the suction supply surface ( Pa abs or psia ) p_0 = \text{Absolute pressure on the suction supply surface } (\text{Pa abs or psia}) p 0 = Absolute pressure on the suction supply surface ( Pa abs or psia ) . For open tanks, p 0 = p atm p_0 = p_{\text{atm}} p 0 = p atm . For closed pressurized deaerators/condensers, p 0 = p tank, abs p_0 = p_{\text{tank, abs}} p 0 = p tank, abs .
z s = Static elevation difference between liquid surface and pump impeller centerline z_s = \text{Static elevation difference between liquid surface and pump impeller centerline} z s = Static elevation difference between liquid surface and pump impeller centerline . (Positive for flooded suction ; negative for suction lift ).
h f s = Total head loss in the suction piping system = ( f L s D s + ∑ K s ) V s 2 2 g h_{fs} = \text{Total head loss in the suction piping system} = \left( f \frac{L_s}{D_s} + \sum K_s \right) \frac{V_s^2}{2g} h f s = Total head loss in the suction piping system = ( f D s L s + ∑ K s ) 2 g V s 2 .
p v = Absolute saturation vapor pressure of the pumped liquid at operating temperature p_v = \text{Absolute saturation vapor pressure of the pumped liquid at operating temperature} p v = Absolute saturation vapor pressure of the pumped liquid at operating temperature .
γ = ρ g = Specific weight of the pumped fluid at operating temperature \gamma = \rho g = \text{Specific weight of the pumped fluid at operating temperature} γ = ρ g = Specific weight of the pumped fluid at operating temperature .
Thoma's Cavitation Parameter ( σ \sigma σ ) σ = N P S H R H \sigma = \frac{NPSHR}{H} σ = H NPS H R
Cavitation begins when the plant suction condition reaches the critical cavitation parameter: σ plant = N P S H A H ≤ σ c \sigma_{\text{plant}} = \frac{NPSHA}{H} \le \sigma_c σ plant = H NPS H A ≤ σ c .
Corrective Strategies to Increase NPSHA When N P S H A < N P S H R NPSHA < NPSHR NPS H A < NPS H R :
Raise the suction supply vessel elevation (increase + z s +z_s + z s ).
Lower the pump elevation into a pit or basement.
Increase the suction pipe diameter D s D_s D s (reduces velocity V s V_s V s and dramatically lowers friction h f s ∝ 1 / D 5 h_{fs} \propto 1/D^5 h f s ∝ 1/ D 5 ).
Remove restrictive suction valves, eliminate elbows, or replace standard elbows with long-radius sweeps.
Subcool the fluid to lower saturation vapor pressure p v p_v p v .
Select a larger pump operating at a lower rotational speed N N N .
- 6. Step-by-Step Worked Engineering Problem
- Problem Statement
A centrifugal pump transfers hot industrial water at 80 ∘ C 80^\circ\text{C} 8 0 ∘ C ( 176 ∘ F 176^\circ\text{F} 17 6 ∘ F ) from an open atmospheric storage reservoir ( p atm = 101.3 kPa p_{\text{atm}} = 101.3\text{ kPa} p atm = 101.3 kPa ) to an elevated pressurized process reactor at a rate of Q = 120 m 3 / h Q = 120\text{ m}^3/\text{h} Q = 120 m 3 / h ( 0.03333 m 3 / s = 33.33 L/s 0.03333\text{ m}^3/\text{s} = 33.33\text{ L/s} 0.03333 m 3 / s = 33.33 L/s ). The pump is located 2.5 m 2.5\text{ m} 2.5 m below the reservoir water surface (flooded suction, z s = + 2.5 m z_s = +2.5\text{ m} z s = + 2.5 m ). The suction line consists of 12 m 12\text{ m} 12 m of 150 mm 150\text{ mm} 150 mm inner diameter pipe with total friction and minor loss coefficient ∑ ( f L / D + K ) = 3.2 \sum (f L/D + K) = 3.2 ∑ ( f L / D + K ) = 3.2 .
Water properties at 80 ∘ C 80^\circ\text{C} 8 0 ∘ C :
Density: ρ = 971.8 kg/m 3 \rho = 971.8\text{ kg/m}^3 ρ = 971.8 kg/m 3
Specific weight: γ = ρ g = 971.8 × 9.81 = 9.533 kN/m 3 \gamma = \rho g = 971.8 \times 9.81 = 9.533\text{ kN/m}^3 γ = ρ g = 971.8 × 9.81 = 9.533 kN/m 3
Saturation vapor pressure: p v = 47.39 kPa abs p_v = 47.39\text{ kPa abs} p v = 47.39 kPa abs
The pump manufacturer curve specifies N P S H R = 4.2 m NPSHR = 4.2\text{ m} NPS H R = 4.2 m at this operating flow. The total dynamic head required by the system is H = 45.0 m H = 45.0\text{ m} H = 45.0 m with pump efficiency η p = 0.76 \eta_p = 0.76 η p = 0.76 .
Determine:
The suction line velocity V s V_s V s and suction line head loss h f s h_{fs} h f s .
The Net Positive Suction Head Available ( N P S H A NPSHA NPS H A ) and the cavitation safety margin ( N P S H A − N P S H R NPSHA - NPSHR NPS H A − NPS H R ).
The pump Brake Horsepower ( B H P BHP B H P ) in kilowatts.
- Step-by-Step Solution
- Step 1: Suction Line Velocity & Friction Loss
Suction pipe area: A s = π ( 0.150 ) 2 4 = 0.01767 m 2 A_s = \frac{\pi (0.150)^2}{4} = 0.01767\text{ m}^2 A s = 4 π ( 0.150 ) 2 = 0.01767 m 2 .
Velocity: V s = 0.03333 m 3 / s 0.01767 m 2 = 1.886 m/s V_s = \frac{0.03333\text{ m}^3/\text{s}}{0.01767\text{ m}^2} = 1.886\text{ m/s} V s = 0.01767 m 2 0.03333 m 3 / s = 1.886 m/s .
Velocity head: V s 2 2 g = ( 1.886 ) 2 2 × 9.81 = 3.557 19.62 = 0.1813 m \frac{V_s^2}{2g} = \frac{(1.886)^2}{2 \times 9.81} = \frac{3.557}{19.62} = 0.1813\text{ m} 2 g V s 2 = 2 × 9.81 ( 1.886 ) 2 = 19.62 3.557 = 0.1813 m .
Suction head loss: h f s = [ ∑ ( f L D + K ) ] V s 2 2 g = 3.2 × 0.1813 m = 0.580 m h_{fs} = \left[ \sum \left( f \frac{L}{D} + K \right) \right] \frac{V_s^2}{2g} = 3.2 \times 0.1813\text{ m} = 0.580\text{ m} h f s = [ ∑ ( f D L + K ) ] 2 g V s 2 = 3.2 × 0.1813 m = 0.580 m
Step 2: Net Positive Suction Head Available ( N P S H A NPSHA NPS H A )
Convert pressures to head of pumped liquid at 80 ∘ C 80^\circ\text{C} 8 0 ∘ C : p 0 γ = 101.325 kPa 9.533 kN/m 3 = 10.629 m \frac{p_0}{\gamma} = \frac{101.325\text{ kPa}}{9.533\text{ kN/m}^3} = 10.629\text{ m} γ p 0 = 9.533 kN/m 3 101.325 kPa = 10.629 m p v γ = 47.39 kPa 9.533 kN/m 3 = 4.971 m \frac{p_v}{\gamma} = \frac{47.39\text{ kPa}}{9.533\text{ kN/m}^3} = 4.971\text{ m} γ p v = 9.533 kN/m 3 47.39 kPa = 4.971 m
Calculate N P S H A NPSHA NPS H A : N P S H A = p 0 γ + z s − h f s − p v γ NPSHA = \frac{p_0}{\gamma} + z_s - h_{fs} - \frac{p_v}{\gamma} NPS H A = γ p 0 + z s − h f s − γ p v N P S H A = 10.629 m + 2.500 m − 0.580 m − 4.971 m = 7.578 m ≈ 7.58 m NPSHA = 10.629\text{ m} + 2.500\text{ m} - 0.580\text{ m} - 4.971\text{ m} = 7.578\text{ m} \approx 7.58\text{ m} NPS H A = 10.629 m + 2.500 m − 0.580 m − 4.971 m = 7.578 m ≈ 7.58 m
Cavitation Margin: Margin = N P S H A − N P S H R = 7.58 m − 4.20 m = + 3.38 m > 0 ( Safe from Cavitation ) \text{Margin} = NPSHA - NPSHR = 7.58\text{ m} - 4.20\text{ m} = +3.38\text{ m} > 0 \quad (\text{Safe from Cavitation}) Margin = NPS H A − NPS H R = 7.58 m − 4.20 m = + 3.38 m > 0 ( Safe from Cavitation )
Step 3: Brake Horsepower Calculation
Hydraulic Power: P hyd = γ Q H = ( 9533 N/m 3 ) × ( 0.03333 m 3 / s ) × ( 45.0 m ) = 14 , 297 W = 14.30 kW P_{\text{hyd}} = \gamma Q H = (9533\text{ N/m}^3) \times (0.03333\text{ m}^3/\text{s}) \times (45.0\text{ m}) = 14,297\text{ W} = 14.30\text{ kW} P hyd = γ Q H = ( 9533 N/m 3 ) × ( 0.03333 m 3 / s ) × ( 45.0 m ) = 14 , 297 W = 14.30 kW
Brake Power required at pump shaft: P brake = P hyd η p = 14.297 kW 0.76 = 18.81 kW P_{\text{brake}} = \frac{P_{\text{hyd}}}{\eta_p} = \frac{14.297\text{ kW}}{0.76} = 18.81\text{ kW} P brake = η p P hyd = 0.76 14.297 kW = 18.81 kW
7. Common Exam Traps & PE Pro-Tips
Tip
Boiler Feedwater / Deaerator NPSH Rule: In closed deaerators or saturated steam drums, the water surface is in saturated thermodynamic equilibrium with the vapor space above it ( p 0 = p v p_0 = p_v p 0 = p v ). Thus, p 0 γ − p v γ = 0 \frac{p_0}{\gamma} - \frac{p_v}{\gamma} = 0 γ p 0 − γ p v = 0 , reducing the NPSHA equation strictly to: N P S H A = z s − h f s NPSHA = z_s - h_{fs} NPS H A = z s − h f s In such systems, the deaerator tank must be elevated high above the feed pump ( z s > N P S H R + h f s z_s > NPSHR + h_{fs} z s > NPS H R + h f s ) ; suction lift is physically impossible.
Warning
Common Traps to Avoid:
Trap 1 — Gauge Pressure in NPSHA: Never plug gauge pressure into p 0 p_0 p 0 or p v p_v p v . If p atm = 14.7 psia p_{\text{atm}} = 14.7\text{ psia} p atm = 14.7 psia and you plug in 0 psig 0\text{ psig} 0 psig , the computed NPSHA will be negative and completely wrong.
Trap 2 — Specific Gravity in Power vs. Head: A centrifugal pump with a given impeller at a fixed speed produces the exact same head in feet (or meters) regardless of liquid density. However, the Brake Horsepower ( B H P BHP B H P ) scales directly with specific gravity ( S G SG SG ) . Pumping brine ( S G = 1.2 SG=1.2 SG = 1.2 ) requires 20% more motor power than pumping pure water.