Study guide
4.5 Radiation Heat Transfer, View Factors & Heat Exchanger Sizing (LMTD/NTU)
PE Mechanical Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Exam Overview, Reference Handbook & Mechanical Engineering Fundamentals
1.1 NCEES PE Mechanical CBT Format, Three Disciplines & Reference Handbook Strategy 1.2 Engineering Economics, Cash Flow & Project Evaluation and Scheduling 1.3 Units, Dimensional Analysis & Physical Constants 1.4 Statics, Dynamics & Mechanical Equilibrium
2 Chapter 2: Mechanical Design & Analysis (Stress, Failure Theories & Components)
2.1 Stress, Strain, Principal Stresses & Combined Loading 2.2 Static Failure Theories for Ductile and Brittle Materials 2.3 Fatigue Analysis, S-N Curves & Fluctuating Stresses 2.4 Pressure Vessels, Column Buckling & Spring Design 2.5 Threaded Fasteners, Welded Connections & Mechanical Joints
3 Chapter 3: Mechanical Power Transmission, Mechanisms & Vibrations
3.1 Shaft Sizing, Torsional Deflection & Critical Speeds 3.2 Spur, Helical, Bevel & Worm Gears and Epicyclic Gear Trains 3.3 Rolling-Element & Journal Bearings, Power Screws, Clutches, Brakes & Flywheels 3.4 Four-Bar Linkages, Cam-Follower Systems & Kinematics 3.5 Single-DOF and 2-DOF Vibrations, Damping & Dynamic Balancing
4 Chapter 4: Thermal & Fluid Systems
4.1 Fluid Statics, Manometry, Submerged Surfaces & Buoyancy 4.2 Incompressible Pipe Flow, Darcy-Weisbach & Minor Losses 4.3 Pump Selection, System Curves, NPSH & Cavitation 4.4 Steady & Transient Conduction, Forced & Natural Convection 4.5 Radiation Heat Transfer, View Factors & Heat Exchanger Sizing (LMTD/NTU)
5 Chapter 5: Power Plants & Energy Conversion Systems
5.1 Thermodynamic Properties, Pure Substances & 1st/2nd Laws 5.2 Vapor Power Cycles (Rankine, Superheat, Reheat & Regeneration) 5.3 Gas Power Cycles (Brayton, Otto, Diesel, Dual & Combined Cycle) 5.4 Combustion Stoichiometry, Flue Gas Analysis & Thermochemistry 5.5 Turbomachinery, Compressible Flow & Nozzles, Renewables & Energy Storage
6 Chapter 6: HVAC & Refrigeration Systems
6.1 Psychrometric Principles & Air-Conditioning Processes 6.2 Cooling & Heating Load Calculations (CLTD/SCL/CLF & Heat Balance) 6.3 Vapor-Compression Refrigeration Cycles & Refrigerant Properties 6.4 Refrigeration Equipment (Compressors, Evaporators, Condensers, Expansion Devices) & Safety Codes 6.5 Air Distribution, Duct Design, Fans & Hydronic Water Networks 6.6 Energy Recovery Devices, HVAC Acoustics & Vibration Isolation
7 Chapter 7: Materials, Manufacturing & Processing
7.1 Ferrous/Non-Ferrous Metals, Polymers, Ceramics & Composites 7.2 Iron-Carbon Equilibrium Phase Diagram & Heat Treatment Processes 7.3 Corrosion, Wear, Creep, Hydrogen Embrittlement & Fracture Mechanics 7.4 Casting, Metal Forming, Forging, Stamping & Powder Metallurgy 7.5 Machining Dynamics, Tool Wear, Welding Metallurgy & Non-Destructive Examination (NDE)
8 Chapter 8: Measurements, Controls, Codes & Engineering Ethics
8.1 Temperature, Pressure, Flow & Strain Transducers and Signal Conditioning 8.2 Feedback Control Loops, PID Tuning, Frequency Response & Stability 8.3 ASME Boiler & Pressure Vessel Code, ASHRAE, OSHA & NFPA Safety Standards 8.4 NCEES Model Rules, Engineering Ethics & Professional Seal Liability
4.5 Radiation Heat Transfer, View Factors & Heat Exchanger Sizing (LMTD/NTU)
Key Takeaways Explain This Topic AI
Blackbody radiation emissive power is defined by the Stefan-Boltzmann Law E b = σ T 4 E_b = \sigma T^4 E b = σ T 4 (where T T T must be in absolute Kelvin or Rankine), while Wien's displacement law λ max T = 2898 μ m ⋅ K \lambda_{\max} T = 2898\;\mu\text{m}\cdot\text{K} λ m a x T = 2898 μ m ⋅ K locates peak spectral emission.
Radiation exchange between gray, diffuse surfaces in an enclosure is modeled via electrical network analogies with surface resistances R surf = 1 − ϵ ϵ A R_{\text{surf}} = \frac{1-\epsilon}{\epsilon A} R surf = ϵ A 1 − ϵ and spatial geometric view factor resistances R space = 1 A i F i j R_{\text{space}} = \frac{1}{A_i F_{ij}} R space = A i F ij 1 .
Heat exchanger duty is analyzed via the Log Mean Temperature Difference method q = U A F Δ T lm q = U A F \Delta T_{\text{lm}} q = U A F Δ T lm , where counter-flow configuration always maximizes Δ T lm \Delta T_{\text{lm}} Δ T lm and enables outlet temperature crossover.
When fluid outlet temperatures are unknown, the Effectiveness-NTU ( ϵ \epsilon ϵ -NTU) method eliminates iterative guesswork by defining ϵ = q q max = q C min ( T h , in − T c , in ) \epsilon = \frac{q}{q_{\max}} = \frac{q}{C_{\min}(T_{h,\text{in}} - T_{c,\text{in}})} ϵ = q m a x q = C m i n ( T h , in − T c , in ) q as a function of N T U = U A C min NTU = \frac{U A}{C_{\min}} NT U = C m i n U A and C r = C min C max C_r = \frac{C_{\min}}{C_{\max}} C r = C m a x C m i n .
Inserting N N N radiation shields of equal emissivity between two large parallel plates reduces net radiation heat transfer by a factor of exactly 1 N + 1 \frac{1}{N+1} N + 1 1 .
Last updated: August 2026
Radiation Heat Transfer, View Factors & Heat Exchanger Sizing (LMTD/NTU)
Thermal radiation and heat exchanger design encompass the final foundational pillars of thermal-fluid engineering. Unlike conduction and convection, thermal radiation requires no intervening physical medium, propagating via electromagnetic waves at the speed of light. Meanwhile, heat exchangers represent the practical mechanical hardware—ranging from compact plate-fin units to multi-pass shell-and-tube condensers—that transfers thermal energy between fluid streams. This section develops blackbody radiation physics , gray enclosure network algebra , and the dual LMTD and ϵ \epsilon ϵ -NTU heat exchanger design frameworks. +---------------------------------------------------------------------------------------------------+
- | RADIATION & HEAT EXCHANGER ARCHITECTURE |
- | |
- | [RADIATION LAWS] [ENCLOSURE NETWORKS] [HEAT EXCHANGER DESIGN] |
- | - E_b = \sigma * T^4 - Surface: (1-\epsilon)/(\epsilon*A) - Duty: q = U*A*F*\Delta T_lm |
- | - Wien: \lambda_max*T = 2898 - Space: 1 / (A_i * F_ij) - LMTD: Counter vs Parallel Flow |
- | - Real: \alpha+\rho+\tau = 1 - Shields: q_N = q_0 / (N+1) - \epsilon-NTU: q = \epsilon*C_min*\Delta T_max |
- +---------------------------------------------------------------------------------------------------+
- 1. Fundamentals of Thermal Radiation & Blackbody Laws
Thermal radiation spans the electromagnetic spectrum from λ = 0.1 μ m \lambda = 0.1\;\mu\text{m} λ = 0.1 μ m to 100 μ m 100\;\mu\text{m} 100 μ m (ultraviolet, visible, and infrared). A blackbody is an ideal surface that absorbs 100% of all incident radiation regardless of wavelength or direction, and emits the maximum possible energy at any given temperature.
Stefan-Boltzmann Law
The total hemispherical emissive power E b E_b E b of a blackbody is proportional to the fourth power of its absolute temperature: E b = σ T 4 E_b = \sigma T^4 E b = σ T 4
Where:
σ = Stefan-Boltzmann Constant = 5.670 × 10 − 8 W/(m 2 ⋅ K 4 ) = 0.1714 × 10 − 8 BTU/(hr ⋅ ft 2 ⋅ ∘ R 4 ) \sigma = \text{Stefan-Boltzmann Constant} = 5.670 \times 10^{-8}\text{ W/(m}^2\cdot\text{K}^4) = 0.1714 \times 10^{-8}\text{ BTU/(hr}\cdot\text{ft}^2\cdot^\circ\text{R}^4) σ = Stefan-Boltzmann Constant = 5.670 × 1 0 − 8 W/(m 2 ⋅ K 4 ) = 0.1714 × 1 0 − 8 BTU/(hr ⋅ ft 2 ⋅ ∘ R 4 )
T = Absolute Temperature (MUST be in Kelvin or Rankine) T = \text{Absolute Temperature (MUST be in Kelvin or Rankine)} T = Absolute Temperature (MUST be in Kelvin or Rankine) +---------------------------------------------------------------------------------------------------+
- | SPECTRAL RADIATION DISTRIBUTION & WIEN'S LAW |
- | |
- | Planck's Spectral Law: E_{b\lambda}(\lambda, T) = \frac{C_1}{\lambda^5 [\exp(C_2 / \lambda T) - 1]} |
- | where C_1 = 3.742 \times 10^8 W·\mu m^4/m^2, C_2 = 1.439 \times 10^4 \mu m·K |
- | |
- | Wien's Displacement Law: \lambda_{\max} T = 2897.8\;\mu\text{m}\cdot\text{K} |
- | = 5216.4\;\mu\text{m}\cdot^\circ\text{R} |
+---------------------------------------------------------------------------------------------------+ Spectral Emissive Power E_b\lambda
- ^
- | T_1 = 5800 K (Sun: Peak in visible ~0.5 \mu m)
- | /\
- | / \
- | / \ T_2 = 1500 K (Industrial Furnace)
- | / \ /\
- | / \_____/ \ T_3 = 300 K (Ambient: Peak in IR ~10 \mu m)
- | / \_______/\
- +-----+------------------------------+---------------------------> Wavelength \lambda (\mu m)
- 0.4 0.7 (Visible Spectrum)
- Real Surface Properties & Kirchhoff's Law
For real surfaces interacting with irradiation G G G (incident radiation power per unit area): α + ρ + τ = 1 \alpha + \rho + \tau = 1 α + ρ + τ = 1
Where α = absorptivity \alpha = \text{absorptivity} α = absorptivity , ρ = reflectivity \rho = \text{reflectivity} ρ = reflectivity , τ = transmissivity \tau = \text{transmissivity} τ = transmissivity . For opaque solids, τ = 0 ⟹ α + ρ = 1 \tau = 0 \implies \alpha + \rho = 1 τ = 0 ⟹ α + ρ = 1 .
Emissivity ( ϵ \epsilon ϵ ): Ratio of radiation emitted by a real surface to that emitted by a blackbody at the same temperature: ϵ = E ( T ) E b ( T ) ≤ 1.0 \epsilon = \frac{E(T)}{E_b(T)} \le 1.0 ϵ = E b ( T ) E ( T ) ≤ 1.0 .
Kirchhoff's Law: Under conditions of thermal equilibrium ( T surface = T source T_{\text{surface}} = T_{\text{source}} T surface = T source ), total hemispherical emissivity equals absorptivity: ϵ = α \epsilon = \alpha ϵ = α .
Gray and Diffuse Surface Approximation: A gray surface has spectral properties independent of wavelength ( ϵ λ = const \epsilon_\lambda = \text{const} ϵ λ = const ), while a diffuse surface emits and reflects uniformly in all directions. Under this approximation, ϵ = α \epsilon = \alpha ϵ = α applies universally.
- 2. Radiation View Factors & Enclosure Network Analysis
- View Factor Definitions & Fundamental Rules
The view factor (shape factor) F i j F_{ij} F ij is defined as the fraction of diffuse radiation leaving surface i i i that directly impinges on surface j j j . +---------------------------------------------------------------------------------------------------+
- | VIEW FACTOR ALGEBRAIC IDENTITIES |
- | |
- | 1. Reciprocity Relation: A_i F_{ij} = A_j F_{ji} |
- | |
- | 2. Summation Rule: \sum_{j=1}^N F_{ij} = 1.0 (for an N-surface closed enclosure) |
- | |
- | 3. Self-Viewing Rule: F_{ii} = 0 (for planar or convex surfaces) |
- | F_{ii} > 0 (for concave surfaces that "see" themselves) |
- | |
- | 4. Superposition Rule: F_{i \to (j+k)} = F_{ij} + F_{ik} |
- +---------------------------------------------------------------------------------------------------+
- Radiation Network Circuit Method (Oppenheim Analogy)
Radiosity J i J_i J i is the total radiation energy leaving surface i i i per unit area (emission plus reflected irradiation): J i = ϵ i E b , i + ρ i G i J_i = \epsilon_i E_{b,i} + \rho_i G_i J i = ϵ i E b , i + ρ i G i . +---------------------------------------------------------------------------------------------------+
- | RADIATION NETWORK RESISTANCE COMPONENTS |
- | |
- | 1. Surface Resistance (Potential: E_bi - J_i): R_{\text{surf},i} = \frac{1-\epsilon_i}{\epsilon_i A_i} |
- | |
- | 2. Spatial / Geometric Resistance (Potential: J_i - J_j): R_{\text{space},ij} = \frac{1}{A_i F_{ij}} |
+---------------------------------------------------------------------------------------------------+ [ Blackbody E_b1 ] ----( R_surf,1 = (1-\epsilon_1)/(\epsilon_1*A_1) )---- [ Radiosity J_1 ]
- |
- ( R_space = 1 / (A_1 * F_12) )
- |
- [ Blackbody E_b2 ] ----( R_surf,2 = (1-\epsilon_2)/(\epsilon_2*A_2) )---- [ Radiosity J_2 ]
Net Heat Exchange Between Two Gray Diffuse Surfaces in an Enclosure: q 12 = σ ( T 1 4 − T 2 4 ) 1 − ϵ 1 ϵ 1 A 1 + 1 A 1 F 12 + 1 − ϵ 2 ϵ 2 A 2 q_{12} = \frac{\sigma(T_1^4 - T_2^4)}{\frac{1-\epsilon_1}{\epsilon_1 A_1} + \frac{1}{A_1 F_{12}} + \frac{1-\epsilon_2}{\epsilon_2 A_2}} q 12 = ϵ 1 A 1 1 − ϵ 1 + A 1 F 12 1 + ϵ 2 A 2 1 − ϵ 2 σ ( T 1 4 − T 2 4 )
Special Classic Two-Surface Geometries
Configuration Geometry Conditions Heat Exchange Rate ( q 12 q_{12} q 12 )
Large Infinite Parallel Plates A 1 = A 2 = A , F 12 = 1.0 A_1 = A_2 = A, \; F_{12} = 1.0 A 1 = A 2 = A , F 12 = 1.0 q 12 = A σ ( T 1 4 − T 2 4 ) 1 ϵ 1 + 1 ϵ 2 − 1 q_{12} = \frac{A \sigma (T_1^4 - T_2^4)}{\frac{1}{\epsilon_1} + \frac{1}{\epsilon_2} - 1} q 12 = ϵ 1 1 + ϵ 2 1 − 1 A σ ( T 1 4 − T 2 4 )
Long Concentric Cylinders A 1 = 2 π r 1 L , F 12 = 1.0 A_1 = 2\pi r_1 L, \; F_{12} = 1.0 A 1 = 2 π r 1 L , F 12 = 1.0 q 12 = A 1 σ ( T 1 4 − T 2 4 ) 1 ϵ 1 + 1 − ϵ 2 ϵ 2 ( r 1 r 2 ) q_{12} = \frac{A_1 \sigma (T_1^4 - T_2^4)}{\frac{1}{\epsilon_1} + \frac{1-\epsilon_2}{\epsilon_2}\left(\frac{r_1}{r_2}\right)} q 12 = ϵ 1 1 + ϵ 2 1 − ϵ 2 ( r 2 r 1 ) A 1 σ ( T 1 4 − T 2 4 )
Small Convex Body in Large Room A 1 ≪ A 2 ⟹ A 1 A 2 ≈ 0 A_1 \ll A_2 \implies \frac{A_1}{A_2} \approx 0 A 1 ≪ A 2 ⟹ A 2 A 1 ≈ 0 q 12 = ϵ 1 A 1 σ ( T 1 4 − T 2 4 ) q_{12} = \epsilon_1 A_1 \sigma (T_1^4 - T_2^4) q 12 = ϵ 1 A 1 σ ( T 1 4 − T 2 4 )
Radiation Shields
Inserting N N N thin, highly reflective radiation shields of emissivity ϵ s \epsilon_s ϵ s between two large parallel plates with emissivity ϵ 1 = ϵ 2 = ϵ \epsilon_1 = \epsilon_2 = \epsilon ϵ 1 = ϵ 2 = ϵ reduces heat transfer to: q N -shields = 1 N + 1 q no shield ( when ϵ s = ϵ ) q_{N\text{-shields}} = \frac{1}{N + 1} q_{\text{no shield}} \quad (\text{when } \epsilon_s = \epsilon) q N -shields = N + 1 1 q no shield ( when ϵ s = ϵ ) General Case: q = A σ ( T 1 4 − T 2 4 ) ( 1 ϵ 1 + 1 ϵ 2 − 1 ) + ∑ i = 1 N ( 2 ϵ s , i − 1 ) \text{General Case: } q = \frac{A \sigma (T_1^4 - T_2^4)}{\left(\frac{1}{\epsilon_1} + \frac{1}{\epsilon_2} - 1\right) + \sum_{i=1}^N \left(\frac{2}{\epsilon_{s,i}} - 1\right)} General Case: q = ( ϵ 1 1 + ϵ 2 1 − 1 ) + ∑ i = 1 N ( ϵ s , i 2 − 1 ) A σ ( T 1 4 − T 2 4 )
3. Heat Exchanger Classifications & Overall Heat Transfer Coefficient ( U U U )
Heat exchangers transfer thermal energy between a hot fluid stream (cooling down from T h , in T_{h,\text{in}} T h , in to T h , out T_{h,\text{out}} T h , out ) and a cold fluid stream (heating up from T c , in T_{c,\text{in}} T c , in to T c , out T_{c,\text{out}} T c , out ). +---------------------------------------------------------------------------------------------------+
- | HEAT EXCHANGER CLASSIFICATION SCHEMES |
- | |
- | 1. Double-Pipe (Concentric Tube): Parallel-Flow (Co-current) vs. Counter-Flow (Opposing) |
- | 2. Shell-and-Tube: 1-Shell Pass / 2-Tube Pass (1-2), 2-Shell Pass / 4-Tube Pass (2-4), Baffles |
- | 3. Cross-Flow: Fluids flow perpendicular (Unmixed/Unmixed, Mixed/Unmixed, Mixed/Mixed) |
- | 4. Plate-and-Frame: High surface area per unit volume, corrugated channels, low fouling |
- +---------------------------------------------------------------------------------------------------+
- Overall Heat Transfer Coefficient ( U U U )
The overall heat transfer coefficient accounts for internal convection, tube wall conduction, external convection, and fouling resistance ( R f R_f R f ) on both fluid sides: 1 U A = 1 U i A i = 1 U o A o = 1 h i A i + R f , i A i + ln ( r o / r i ) 2 π k L + R f , o A o + 1 h o A o \frac{1}{U A} = \frac{1}{U_i A_i} = \frac{1}{U_o A_o} = \frac{1}{h_i A_i} + \frac{R_{f,i}}{A_i} + \frac{\ln(r_o/r_i)}{2\pi k L} + \frac{R_{f,o}}{A_o} + \frac{1}{h_o A_o} U A 1 = U i A i 1 = U o A o 1 = h i A i 1 + A i R f , i + 2 πk L ln ( r o / r i ) + A o R f , o + h o A o 1
Where R f , i R_{f,i} R f , i and R f , o R_{f,o} R f , o are fouling factors (unit thermal resistance due to scale, corrosion, or biological buildup, in m 2 ⋅ K/W \text{m}^2\cdot\text{K/W} m 2 ⋅ K/W or hr ⋅ ft 2 ⋅ ∘ F/BTU \text{hr}\cdot\text{ft}^2\cdot^\circ\text{F/BTU} hr ⋅ ft 2 ⋅ ∘ F/BTU ).
4. Log Mean Temperature Difference (LMTD) Method
The total steady-state heat exchanger duty q q q is governed by energy conservation across both fluid streams: q = m ˙ h c p , h ( T h , in − T h , out ) = m ˙ c c p , c ( T c , out − T c , in ) = U A F Δ T lm q = \dot{m}_h c_{p,h} (T_{h,\text{in}} - T_{h,\text{out}}) = \dot{m}_c c_{p,c} (T_{c,\text{out}} - T_{c,\text{in}}) = U A F \Delta T_{\text{lm}} q = m ˙ h c p , h ( T h , in − T h , out ) = m ˙ c c p , c ( T c , out − T c , in ) = U A F Δ T lm +---------------------------------------------------------------------------------------------------+
- | LMTD TEMPERATURE PROFILE FORMULATIONS |
- | |
- | COUNTER-FLOW PROFILE: PARALLEL-FLOW PROFILE: |
- | \Delta T_1 = T_{h,\text{in}} - T_{c,\text{out}} \Delta T_1 = T_{h,\text{in}} - T_{c,\text{in}}|
- | \Delta T_2 = T_{h,\text{out}} - T_{c,\text{in}} \Delta T_2 = T_{h,\text{out}} - T_{c,\text{out}}|
- | |
| Log Mean Temperature Difference: \Delta T_{\text{lm}} = \frac{\Delta T_1 - \Delta T_2}{\ln(\Delta T_1 / \Delta T_2)} |
| (Note: If \Delta T_1 = \Delta T_2, then \Delta T_{\text{lm}} = \Delta T_1) |
+---------------------------------------------------------------------------------------------------+ Counter-Flow: Parallel-Flow:
- Hot: T_h,in ======> T_h,out Hot: T_h,in ======> T_h,out
- Cold: T_c,out <===== T_c,in Cold: T_c,in ======> T_c,out
- (Enables T_c,out > T_h,out: "Temperature Cross") (T_c,out can NEVER exceed T_h,out)
- Multipass Shell-and-Tube Correction Factor ( F F F )
For multipass shell-and-tube or cross-flow exchangers, fluid streams do not flow in pure counter-flow. An empirical LMTD correction factor F ≤ 1.0 F \le 1.0 F ≤ 1.0 is applied: q = U A F Δ T lm, CF q = U A F \Delta T_{\text{lm, CF}} q = U A F Δ T lm, CF
Where Δ T lm, CF \Delta T_{\text{lm, CF}} Δ T lm, CF is computed using the counter-flow terminal formulas, and F F F is evaluated using dimensionless temperature ratio P P P and heat capacity ratio R R R : P = t 2 − t 1 T 1 − t 1 = T tube,out − T tube,in T shell,in − T tube,in , R = T 1 − T 2 t 2 − t 1 = T shell,in − T shell,out T tube,out − T tube,in P = \frac{t_2 - t_1}{T_1 - t_1} = \frac{T_{\text{tube,out}} - T_{\text{tube,in}}}{T_{\text{shell,in}} - T_{\text{tube,in}}}, \quad R = \frac{T_1 - T_2}{t_2 - t_1} = \frac{T_{\text{shell,in}} - T_{\text{shell,out}}}{T_{\text{tube,out}} - T_{\text{tube,in}}} P = T 1 − t 1 t 2 − t 1 = T shell,in − T tube,in T tube,out − T tube,in , R = t 2 − t 1 T 1 − T 2 = T tube,out − T tube,in T shell,in − T shell,out
Tip
Rule of Thumb for Exchanger Selection: If the computed correction factor F < 0.75 − 0.80 F < 0.75 - 0.80 F < 0.75 − 0.80 , the design is thermally inefficient and prone to temperature cross instabilities. In such cases, switch from a single-shell pass to a 2-shell-pass or multi-unit series arrangement .
5. Effectiveness-NTU ( ϵ \epsilon ϵ -NTU) Method
When inlet temperatures ( T h , in , T c , in T_{h,\text{in}}, T_{c,\text{in}} T h , in , T c , in ) and stream heat capacities are known, but fluid outlet temperatures are unknown, the LMTD method requires tedious iterative guessing. The ϵ \epsilon ϵ -NTU method solves for heat duty directly. +---------------------------------------------------------------------------------------------------+
- | EFFECTIVENESS-NTU (\epsilon-NTU) FORMULATIONS |
- | |
- | Heat Capacity Rates: C_h = \dot{m}_h c_{p,h}, \quad C_c = \dot{m}_c c_{p,c} |
- | Capacitance Extremes: C_{\min} = \min(C_h, C_c), \quad C_{\max} = \max(C_h, C_c) |
- | Capacity Ratio: C_r = \frac{C_{\min}}{C_{\max}} \le 1.0 |
- | |
- | Maximum Possible Heat: q_{\max} = C_{\min} (T_{h,\text{in}} - T_{c,\text{in}}) |
- | |
| Effectiveness (\epsilon): \epsilon = \frac{q}{q_{\max}} \implies q = \epsilon C_{\min} (T_{h,\text{in}} - T_{c,\text{in}}) |
- | |
- | Number of Transfer Units: NTU = \frac{U A}{C_{\min}} |
- +---------------------------------------------------------------------------------------------------+
Explicit Effectiveness Formulas ϵ ( N T U , C r ) \epsilon(NTU, C_r) ϵ ( NT U , C r ) : +---------------------------------------------------------------------------------------------------+
- | EFFECTIVENESS EQUATIONS BY FLOW TYPE |
- | |
- | 1. COUNTER-FLOW: \epsilon = \frac{1 - \exp[-NTU(1-C_r)]}{1 - C_r \exp[-NTU(1-C_r)]} |
- | (Special case C_r = 1: \epsilon = \frac{NTU}{1 + NTU}) |
- | |
- | 2. PARALLEL-FLOW: \epsilon = \frac{1 - \exp[-NTU(1+C_r)]}{1 + C_r} |
- | |
- | 3. PHASE CHANGE (Boilers / Condensers where C_max -> \infty, C_r = 0): |
- | \epsilon = 1 - e^{-NTU} (Valid for ALL flow configurations!) |
- +---------------------------------------------------------------------------------------------------+
- 6. Step-by-Step Worked Engineering Problem
- Problem Statement
A counter-flow double-pipe heat exchanger is designed to cool engine lubricating oil ( c p , h = 2.10 kJ/kg ⋅ K c_{p,h} = 2.10\text{ kJ/kg}\cdot\text{K} c p , h = 2.10 kJ/kg ⋅ K ) from T h , in = 100 ∘ C T_{h,\text{in}} = 100^\circ\text{C} T h , in = 10 0 ∘ C to T h , out = 60 ∘ C T_{h,\text{out}} = 60^\circ\text{C} T h , out = 6 0 ∘ C using cooling water ( c p , c = 4.18 kJ/kg ⋅ K c_{p,c} = 4.18\text{ kJ/kg}\cdot\text{K} c p , c = 4.18 kJ/kg ⋅ K ) entering at T c , in = 20 ∘ C T_{c,\text{in}} = 20^\circ\text{C} T c , in = 2 0 ∘ C with a flow rate of m ˙ c = 0.80 kg/s \dot{m}_c = 0.80\text{ kg/s} m ˙ c = 0.80 kg/s . The mass flow rate of oil is m ˙ h = 1.20 kg/s \dot{m}_h = 1.20\text{ kg/s} m ˙ h = 1.20 kg/s . The overall heat transfer coefficient is U = 450 W/m 2 ⋅ K U = 450\text{ W/m}^2\cdot\text{K} U = 450 W/m 2 ⋅ K .
Determine:
The total heat transfer rate (duty) q q q in kilowatts.
The water outlet temperature T c , out T_{c,\text{out}} T c , out .
The Log Mean Temperature Difference Δ T lm \Delta T_{\text{lm}} Δ T lm and required heat transfer surface area A A A .
Verify the required area using the ϵ \epsilon ϵ -NTU method.
- Step-by-Step Solution
- Step 1: Compute Heat Transfer Rate ( q q q )
Oil heat capacity rate: C h = m ˙ h c p , h = ( 1.20 kg/s ) × ( 2.10 kJ/kg ⋅ K ) = 2.520 kW/K = 2520 W/K C_h = \dot{m}_h c_{p,h} = (1.20\text{ kg/s}) \times (2.10\text{ kJ/kg}\cdot\text{K}) = 2.520\text{ kW/K} = 2520\text{ W/K} C h = m ˙ h c p , h = ( 1.20 kg/s ) × ( 2.10 kJ/kg ⋅ K ) = 2.520 kW/K = 2520 W/K .
Heat duty from oil stream: q = C h ( T h , in − T h , out ) = ( 2.520 kW/K ) × ( 100 ∘ C − 60 ∘ C ) = 2.520 × 40 = 100.8 kW q = C_h (T_{h,\text{in}} - T_{h,\text{out}}) = (2.520\text{ kW/K}) \times (100^\circ\text{C} - 60^\circ\text{C}) = 2.520 \times 40 = 100.8\text{ kW} q = C h ( T h , in − T h , out ) = ( 2.520 kW/K ) × ( 10 0 ∘ C − 6 0 ∘ C ) = 2.520 × 40 = 100.8 kW
Step 2: Determine Water Outlet Temperature ( T c , out T_{c,\text{out}} T c , out )
Water heat capacity rate: C c = m ˙ c c p , c = ( 0.80 kg/s ) × ( 4.18 kJ/kg ⋅ K ) = 3.344 kW/K = 3344 W/K C_c = \dot{m}_c c_{p,c} = (0.80\text{ kg/s}) \times (4.18\text{ kJ/kg}\cdot\text{K}) = 3.344\text{ kW/K} = 3344\text{ W/K} C c = m ˙ c c p , c = ( 0.80 kg/s ) × ( 4.18 kJ/kg ⋅ K ) = 3.344 kW/K = 3344 W/K .
Energy balance on cold water stream: q = C c ( T c , out − T c , in ) q = C_c (T_{c,\text{out}} - T_{c,\text{in}}) q = C c ( T c , out − T c , in ) : 100.8 kW = 3.344 kW/K × ( T c , out − 20 ∘ C ) 100.8\text{ kW} = 3.344\text{ kW/K} \times (T_{c,\text{out}} - 20^\circ\text{C}) 100.8 kW = 3.344 kW/K × ( T c , out − 2 0 ∘ C ) T c , out − 20 = 100.8 3.344 = 30.14 ∘ C ⟹ T c , out = 50.14 ∘ C T_{c,\text{out}} - 20 = \frac{100.8}{3.344} = 30.14^\circ\text{C} \implies T_{c,\text{out}} = 50.14^\circ\text{C} T c , out − 20 = 3.344 100.8 = 30.1 4 ∘ C ⟹ T c , out = 50.1 4 ∘ C
Step 3: Calculate LMTD and Required Surface Area ( A A A )
Terminal temperature differences for counter-flow: Δ T 1 = T h , in − T c , out = 100.0 ∘ C − 50.14 ∘ C = 49.86 ∘ C \Delta T_1 = T_{h,\text{in}} - T_{c,\text{out}} = 100.0^\circ\text{C} - 50.14^\circ\text{C} = 49.86^\circ\text{C} Δ T 1 = T h , in − T c , out = 100. 0 ∘ C − 50.1 4 ∘ C = 49.8 6 ∘ C Δ T 2 = T h , out − T c , in = 60.0 ∘ C − 20.0 ∘ C = 40.00 ∘ C \Delta T_2 = T_{h,\text{out}} - T_{c,\text{in}} = 60.0^\circ\text{C} - 20.0^\circ\text{C} = 40.00^\circ\text{C} Δ T 2 = T h , out − T c , in = 60. 0 ∘ C − 20. 0 ∘ C = 40.0 0 ∘ C
Log Mean Temperature Difference: Δ T lm = Δ T 1 − Δ T 2 ln ( Δ T 1 / Δ T 2 ) = 49.86 − 40.00 ln ( 49.86 / 40.00 ) = 9.86 ln ( 1.2465 ) = 9.86 0.2203 = 44.75 ∘ C \Delta T_{\text{lm}} = \frac{\Delta T_1 - \Delta T_2}{\ln(\Delta T_1 / \Delta T_2)} = \frac{49.86 - 40.00}{\ln(49.86 / 40.00)} = \frac{9.86}{\ln(1.2465)} = \frac{9.86}{0.2203} = 44.75^\circ\text{C} Δ T lm = ln ( Δ T 1 /Δ T 2 ) Δ T 1 − Δ T 2 = ln ( 49.86/40.00 ) 49.86 − 40.00 = ln ( 1.2465 ) 9.86 = 0.2203 9.86 = 44.7 5 ∘ C
Required area: A = q U Δ T lm = 100 , 800 W ( 450 W/m 2 ⋅ K ) × ( 44.75 K ) = 100 , 800 20 , 138 = 5.005 m 2 ≈ 5.01 m 2 A = \frac{q}{U \Delta T_{\text{lm}}} = \frac{100,800\text{ W}}{(450\text{ W/m}^2\cdot\text{K}) \times (44.75\text{ K})} = \frac{100,800}{20,138} = 5.005\text{ m}^2 \approx 5.01\text{ m}^2 A = U Δ T lm q = ( 450 W/m 2 ⋅ K ) × ( 44.75 K ) 100 , 800 W = 20 , 138 100 , 800 = 5.005 m 2 ≈ 5.01 m 2
Step 4: Verification via ϵ \epsilon ϵ -NTU Method
Capacitance rates: C min = C h = 2.520 kW/K C_{\min} = C_h = 2.520\text{ kW/K} C m i n = C h = 2.520 kW/K , C max = C c = 3.344 kW/K C_{\max} = C_c = 3.344\text{ kW/K} C m a x = C c = 3.344 kW/K .
Heat capacity ratio: C r = C min C max = 2.520 3.344 = 0.7536 C_r = \frac{C_{\min}}{C_{\max}} = \frac{2.520}{3.344} = 0.7536 C r = C m a x C m i n = 3.344 2.520 = 0.7536 .
Maximum possible heat transfer: q max = C min ( T h , in − T c , in ) = ( 2.520 kW/K ) × ( 100 − 20 ) = 2.520 × 80 = 201.6 kW q_{\max} = C_{\min} (T_{h,\text{in}} - T_{c,\text{in}}) = (2.520\text{ kW/K}) \times (100 - 20) = 2.520 \times 80 = 201.6\text{ kW} q m a x = C m i n ( T h , in − T c , in ) = ( 2.520 kW/K ) × ( 100 − 20 ) = 2.520 × 80 = 201.6 kW
Actual effectiveness: ϵ = q q max = 100.8 kW 201.6 kW = 0.5000 \epsilon = \frac{q}{q_{\max}} = \frac{100.8\text{ kW}}{201.6\text{ kW}} = 0.5000 ϵ = q m a x q = 201.6 kW 100.8 kW = 0.5000
Counter-flow NTU inversion formula: N T U = 1 1 − C r ln ( 1 − ϵ C r 1 − ϵ ) = 1 1 − 0.7536 ln ( 1 − ( 0.500 ) ( 0.7536 ) 1 − 0.500 ) NTU = \frac{1}{1 - C_r} \ln\left( \frac{1 - \epsilon C_r}{1 - \epsilon} \right) = \frac{1}{1 - 0.7536} \ln\left( \frac{1 - (0.500)(0.7536)}{1 - 0.500} \right) NT U = 1 − C r 1 ln ( 1 − ϵ 1 − ϵ C r ) = 1 − 0.7536 1 ln ( 1 − 0.500 1 − ( 0.500 ) ( 0.7536 ) ) N T U = 1 0.2464 ln ( 0.6232 0.5000 ) = 4.0584 × ln ( 1.2464 ) = 4.0584 × 0.2203 = 0.8941 NTU = \frac{1}{0.2464} \ln\left( \frac{0.6232}{0.5000} \right) = 4.0584 \times \ln(1.2464) = 4.0584 \times 0.2203 = 0.8941 NT U = 0.2464 1 ln ( 0.5000 0.6232 ) = 4.0584 × ln ( 1.2464 ) = 4.0584 × 0.2203 = 0.8941
Calculate area from N T U = U A C min NTU = \frac{U A}{C_{\min}} NT U = C m i n U A : A = N T U × C min U = 0.8941 × 2520 W/K 450 W/m 2 ⋅ K = 2253.1 450 = 5.007 m 2 ≈ 5.01 m 2 A = \frac{NTU \times C_{\min}}{U} = \frac{0.8941 \times 2520\text{ W/K}}{450\text{ W/m}^2\cdot\text{K}} = \frac{2253.1}{450} = 5.007\text{ m}^2 \approx 5.01\text{ m}^2 A = U NT U × C m i n = 450 W/m 2 ⋅ K 0.8941 × 2520 W/K = 450 2253.1 = 5.007 m 2 ≈ 5.01 m 2
- (Exact agreement confirms both methods)
- 7. Common Exam Traps & PE Pro-Tips
Tip
Quick Check on Saturated Phase Change Exchangers: In steam condensers or refrigerant evaporators, the fluid undergoing phase change stays at constant saturation temperature ( c p → ∞ c_p \to \infty c p → ∞ , so C max → ∞ C_{\max} \to \infty C m a x → ∞ and C r = 0 C_r = 0 C r = 0 ). For C r = 0 C_r = 0 C r = 0 :
The correction factor is always F = 1.0 F = 1.0 F = 1.0 .
The effectiveness simplifies to ϵ = 1 − e − N T U \epsilon = 1 - e^{-NTU} ϵ = 1 − e − NT U regardless of whether the exchanger is counter-flow, parallel-flow, or cross-flow.
Warning
Common Traps to Avoid:
Trap 1 — Absolute Temperature in Radiation: Forgetting to convert temperatures to absolute units (Kelvin: T K = T C + 273.15 T_K = T_C + 273.15 T K = T C + 273.15 or Rankine: T R = T F + 459.67 T_R = T_F + 459.67 T R = T F + 459.67 ) before evaluating T 4 T^4 T 4 . ( 100 4 − 20 4 ) = 9.98 × 10 7 (100^4 - 20^4) = 9.98 \times 10^7 ( 10 0 4 − 2 0 4 ) = 9.98 × 1 0 7 , whereas ( 373 4 − 293 4 ) = 1.199 × 10 10 (373^4 - 293^4) = 1.199 \times 10^{10} ( 37 3 4 − 29 3 4 ) = 1.199 × 1 0 10 —an error of more than two orders of magnitude!
Trap 2 — Identifying C min C_{\min} C m i n : In the ϵ \epsilon ϵ -NTU method, q max = C min ( T h , in − T c , in ) q_{\max} = C_{\min}(T_{h,\text{in}} - T_{c,\text{in}}) q m a x = C m i n ( T h , in − T c , in ) . Never use C max C_{\max} C m a x in the denominator when computing effectiveness ϵ = q / q max \epsilon = q / q_{\max} ϵ = q / q m a x .
Trap 3 — Temperature Cross in Parallel Flow: In a parallel-flow heat exchanger, the cold stream exit temperature T c , out T_{c,\text{out}} T c , out can never exceed the hot stream exit temperature T h , out T_{h,\text{out}} T h , out . If a problem requires T c , out > T h , out T_{c,\text{out}} > T_{h,\text{out}} T c , out > T h , out , only a counter-flow configuration is thermodynamically possible.