Study guide
7.2 Shear Stress, Shear Flow, and Built-Up Sections
PE Civil: Structural Exam
Track your progress as you read
Finished sections get a check mark.
1 Exam Identity and Reference Workflow
2026 PE Civil: Structural Identity, Format, and Scoring Electronic Handbook, Design Standards, Units, and Version Control
2 Chapter 2: Gravity and Construction Loads
2.1 Dead Loads and Self-Weight 2.2 Live Loads, Reduction, and Load Placement 2.3 Construction-Stage Loads
3 Environmental Loads
Wind Loads and Pressure Paths Seismic Loads and Lateral Force Distribution Snow, Rain, and Ice Loads
4 Moving, Impact, and Lateral Soil Loads
Vehicular, Crane, and Other Moving Loads Impact and Dynamic Allowances Earth Pressure and Surcharge Loads
5 Chapter 5: Load Paths and Combinations
5.1 Tributary Areas and Complete Vertical/Lateral Load Paths 5.2 Strength and Service Load Combinations
6 Reactions, Diagrams, and Basic Axial Effects
Free-Body Diagrams, Reactions, Shear, and Moment Qualitative Diagrams, Influence Lines, and Critical Placement Axial Tension, Compression, and Deformation
7 Chapter 7: Axial Systems and Shear Effects
7.1 Trusses, Braces, and Column Axial Force 7.2 Shear Stress, Shear Flow, and Built-Up Sections 7.3 One-Way, Two-Way, Punching, and Interface Shear Effects
8 Flexure
Section Properties and Elastic Flexural Stress Beam and Slab Flexural Load Effects Biaxial and Unsymmetrical Flexure
9 Combined Stress and Deflection
Combined Axial and Flexural Stress Principal Stress, Mohr's Circle, and Combined Shear Elastic Deflection Methods
10 Chapter 10: Serviceability, Torsion, and Stability
10.1 Serviceability: Deflection, Drift, Vibration, and Ponding 10.2 Torsion and Warping Effects 10.3 Buckling, Effective Length, and Second-Order Stability
11 Fatigue, Robustness, Thermal, and Bearing Effects
Fatigue and Progressive-Collapse Concepts Thermal Deformation and Bearing/Contact Stress
12 Inspections, Submittals, and Adjacent Facilities
Special Inspections and Verification Duties Shop Drawings, Submittals, RFIs, and Delegated Design Construction Effects on Adjacent Facilities
13 Chapter 13: Temporary Works and Safety
13.1 Formwork, Falsework, Scaffolding, Shoring/Reshoring, Bracing, and Anchorage 13.2 Construction, Roadside, and Work-Zone Safety
14 Soils and Core Concrete Properties
Soil Phase Relationships and Classification Soil Strength, Permeability, and Compressibility Fresh and Hardened Concrete Properties
15 Chapter 15: Prestressed Concrete and Steel Properties
15.1 Reinforced, Precast, Pretensioned, and Post-Tensioned Concrete Materials 15.2 Structural and Cold-Formed Steel Properties 15.3 Steel Toughness, Weldability, Corrosion, and Temperature Effects
16 Timber, Masonry, and Material Conformance
Timber Properties and ASD Design Values Masonry, CMU, Mortar, Grout, and Brick Veneer Properties Concrete and Masonry Test Methods Steel, Timber, and Other Material Specification Conformance
17 Horizontal Members I
Steel Beams and Girders Reinforced Concrete Beams and Slabs Timber and Masonry Horizontal Members
18 Chapter 18: Diaphragms and Vertical Members
18.1 Diaphragms, Collectors, Struts, and Composite Slabs 18.2 Steel Columns and Beam-Columns 18.3 Concrete Columns and Bearing Walls
19 Shear Walls, Trusses, and Frames
Shear Walls and Vertical Lateral Members Trusses and Braced Systems Moment Frames and Stability Systems
20 Composite/Bridge Systems and Bolted Connections
Composite Construction and Structural System Selection Bridge Systems and Load Distribution Bolted Steel Connections
21 Chapter 21: Welded, Embedded, and Anchored Connections
21.1 Welded Steel Connections 21.2 Bearing, Embedded, and Precast Connections 21.3 Anchors, Post-Installed Anchors, and Wood/Masonry Connections
22 Shallow Foundations
Isolated, Spread, and Strip Footings Combined and Strap Footings Mat Foundations and Foundation Slabs
23 Deep Foundations
Driven Piles: Axial Capacity and Settlement Drilled Shafts, Piers, and Caissons Pile Groups, Caps, and Lateral Deep-Foundation Response
24 Chapter 24: Retaining Structures
24.1 Lateral Earth/Water Pressure and Drainage 24.2 Sliding, Overturning, Bearing, and Global Stability 24.3 Concrete Cantilever, Gravity, and Basement Walls 24.4 Sheet-Pile, Anchored, and Mechanically Stabilized Earth Walls
7.2 Shear Stress, Shear Flow, and Built-Up Sections
Key Takeaways Explain This Topic AI
Average shear V/A is an equilibrium average, while VQ/(It) evaluates elastic transverse shear stress at a specified plane in a beam cross-section.
In VQ/(It) , I belongs to the entire section, Q is the first moment of the area on one side of the evaluation cut, and t is the local material width at that cut.
Shear flow q = VQ/I has force-per-length units and becomes local shear stress only after division by the correct thickness.
Fastener force in a built-up member is commonly shear flow times connector spacing, with connector rows and shear planes handled as the actual detail requires.
A correct interface calculation must use the Q of the component being transferred across that interface, not automatically the half-section value.
Last updated: July 2026
Shear stress is not generally uniform over a beam cross-section. The PE Civil Reference Handbook mechanics formulas distinguish a sectional resultant V , a local stress τ , and an interface force per unit length q . For July 2026, follow the April 2024 Civil: Structural specification , the current handbook, the AISC Steel Construction Manual 15th edition , and NDS 2018 using ASD only for wood. Later reference editions are outside this exam boundary.
Choose the Shear Model
The average expression τ_avg = V/A is useful when a direct shear force is intentionally idealized as uniform across a resisting area, such as a simple pin or punching plane model. It does not reproduce the transverse shear distribution caused by bending in a beam. For an elastic prismatic beam,
τ = VQ/(It)
where:
V is internal shear at the section along the member;
I is the second moment of area of the entire transformed or actual section used in the analysis about its neutral axis;
Q = A'ȳ is the first moment about that neutral axis of the portion A' above or below the evaluation plane; and
t is the local cross-section width through which shear acts at that plane.
First choose the plane, then identify A' and t . At the neutral axis of a rectangle, A' is the top half and t is the full rectangle width. At a flange-web interface, A' is normally the flange and any material outboard of that interface; t for stress just inside the web is the web thickness. Using the top-half Q at every interface or using flange width as web thickness gives the wrong local stress.
Because Q falls to zero at a free top or bottom surface, transverse shear stress is zero there in the elementary beam model. In a rectangle it varies parabolically and reaches 1.5V/A at the neutral axis. In an I-shape, the thin web carries high shear stress because t is small; a low whole-section average can hide that local demand.
Worked Stress Calculation
A rectangular 4 in by 12 in beam carries internal shear V = 6.00 kips . Find the elastic transverse shear stress at its neutral axis.
- For the whole rectangle,
- I = bh^3/12 = (4)(12^3)/12 = 576 in^4
The area above the neutral axis is A' = (4)(6) = 24 in^2 , and its centroid is 3 in above the neutral axis. Therefore,
- Q = A'ȳ = (24)(3) = 72 in^3
- At that plane, t = b = 4 in . Thus,
- τ_max = VQ/(It)
- τ_max = (6,000 lb)(72 in^3)/[(576 in^4)(4 in)] = 187.5 psi
- The independent rectangle check gives
- 1.5V/A = 1.5(6,000)/(4 × 12) = 187.5 psi
so the selected Q , I , and t are consistent. Using V/A = 125 psi would understate the maximum by one-third.
- From Shear Stress to Shear Flow
- Removing local thickness from the stress equation gives
- q = τt = VQ/I
The units are force per unit length: for USCS inputs above, pounds per inch. Shear flow measures the longitudinal force transfer needed between adjacent layers so the cross-section bends together. It is not pressure. For the same 4 in by 12 in section built from two 4 in by 6 in planks joined along the neutral-axis interface,
q = (6,000)(72)/576 = 750 lb/in
If one row of fasteners alone transfers this flow and fasteners are spaced at 3 in, the required force per fastener is
F_fastener = qs = (750 lb/in)(3 in) = 2,250 lb
This demand must be compared with a compatible allowable or design fastener value that accounts for the actual shear planes, spacing, edge distances, material, and load-duration or other code adjustments. If two rows share load, do not divide by two unless symmetry, stiffness, and the problem detail justify equal sharing.
Built-Up and Thin-Walled Details
For a steel plate girder, q at the flange-web junction represents the longitudinal transfer that welds or fasteners must develop. Use the flange-area Q at that junction. For a built-up wood beam, nails, screws, bolts, or adhesive transfer the same type of interface flow, but NDS connection values and ASD-only exam treatment govern capacity. For a multi-cell or open thin-walled shape, direction and continuity of shear flow matter; do not assume one constant value around a changing section without analysis.
A connector group may have more than one interface, row, or shear plane. Sketch the cut surfaces and label which component's longitudinal force changes along the beam. The required transfer over length Δx is approximately qΔx ; discrete fasteners replace that continuous transfer at their spacing. At a location where V changes, q changes proportionally, so constant spacing based on maximum shear is conservative only if code detailing requirements are also satisfied.
Exam Workflow and Checks
Cut the member at the requested longitudinal position and determine V .
Mark the exact cross-section plane where stress or interface transfer is requested.
Compute whole-section I about the correct neutral axis.
Select the area on one side of the plane and compute its Q .
Use local t for stress, or omit t for shear flow.
For connectors, multiply q by spacing and distribute only through justified load paths.
Keep units explicit: stress is force/area; shear flow is force/length; connector demand is force.
Finally, compare demand with the matching AISC or NDS resistance format. Correct mechanics cannot rescue a capacity check that mixes LRFD demand with ASD resistance, and an average stress cannot replace a required local web, interface, or connector check.