Study guide

Bolted Steel Connections

PE Civil: Structural Exam

Track your progress as you read

Finished sections get a check mark.

1 Exam Identity and Reference Workflow

2026 PE Civil: Structural Identity, Format, and Scoring Electronic Handbook, Design Standards, Units, and Version Control

2 Chapter 2: Gravity and Construction Loads

2.1 Dead Loads and Self-Weight 2.2 Live Loads, Reduction, and Load Placement 2.3 Construction-Stage Loads

3 Environmental Loads

Wind Loads and Pressure Paths Seismic Loads and Lateral Force Distribution Snow, Rain, and Ice Loads

4 Moving, Impact, and Lateral Soil Loads

Vehicular, Crane, and Other Moving Loads Impact and Dynamic Allowances Earth Pressure and Surcharge Loads

5 Chapter 5: Load Paths and Combinations

5.1 Tributary Areas and Complete Vertical/Lateral Load Paths 5.2 Strength and Service Load Combinations

6 Reactions, Diagrams, and Basic Axial Effects

Free-Body Diagrams, Reactions, Shear, and Moment Qualitative Diagrams, Influence Lines, and Critical Placement Axial Tension, Compression, and Deformation

7 Chapter 7: Axial Systems and Shear Effects

7.1 Trusses, Braces, and Column Axial Force 7.2 Shear Stress, Shear Flow, and Built-Up Sections 7.3 One-Way, Two-Way, Punching, and Interface Shear Effects

8 Flexure

Section Properties and Elastic Flexural Stress Beam and Slab Flexural Load Effects Biaxial and Unsymmetrical Flexure

9 Combined Stress and Deflection

Combined Axial and Flexural Stress Principal Stress, Mohr's Circle, and Combined Shear Elastic Deflection Methods

10 Chapter 10: Serviceability, Torsion, and Stability

10.1 Serviceability: Deflection, Drift, Vibration, and Ponding 10.2 Torsion and Warping Effects 10.3 Buckling, Effective Length, and Second-Order Stability

11 Fatigue, Robustness, Thermal, and Bearing Effects

Fatigue and Progressive-Collapse Concepts Thermal Deformation and Bearing/Contact Stress

12 Inspections, Submittals, and Adjacent Facilities

Special Inspections and Verification Duties Shop Drawings, Submittals, RFIs, and Delegated Design Construction Effects on Adjacent Facilities

13 Chapter 13: Temporary Works and Safety

13.1 Formwork, Falsework, Scaffolding, Shoring/Reshoring, Bracing, and Anchorage 13.2 Construction, Roadside, and Work-Zone Safety

14 Soils and Core Concrete Properties

Soil Phase Relationships and Classification Soil Strength, Permeability, and Compressibility Fresh and Hardened Concrete Properties

15 Chapter 15: Prestressed Concrete and Steel Properties

15.1 Reinforced, Precast, Pretensioned, and Post-Tensioned Concrete Materials 15.2 Structural and Cold-Formed Steel Properties 15.3 Steel Toughness, Weldability, Corrosion, and Temperature Effects

16 Timber, Masonry, and Material Conformance

Timber Properties and ASD Design Values Masonry, CMU, Mortar, Grout, and Brick Veneer Properties Concrete and Masonry Test Methods Steel, Timber, and Other Material Specification Conformance

17 Horizontal Members I

Steel Beams and Girders Reinforced Concrete Beams and Slabs Timber and Masonry Horizontal Members

18 Chapter 18: Diaphragms and Vertical Members

18.1 Diaphragms, Collectors, Struts, and Composite Slabs 18.2 Steel Columns and Beam-Columns 18.3 Concrete Columns and Bearing Walls

19 Shear Walls, Trusses, and Frames

Shear Walls and Vertical Lateral Members Trusses and Braced Systems Moment Frames and Stability Systems

20 Composite/Bridge Systems and Bolted Connections

Composite Construction and Structural System Selection Bridge Systems and Load Distribution Bolted Steel Connections

21 Chapter 21: Welded, Embedded, and Anchored Connections

21.1 Welded Steel Connections 21.2 Bearing, Embedded, and Precast Connections 21.3 Anchors, Post-Installed Anchors, and Wood/Masonry Connections

22 Shallow Foundations

Isolated, Spread, and Strip Footings Combined and Strap Footings Mat Foundations and Foundation Slabs

23 Deep Foundations

Driven Piles: Axial Capacity and Settlement Drilled Shafts, Piers, and Caissons Pile Groups, Caps, and Lateral Deep-Foundation Response

24 Chapter 24: Retaining Structures

24.1 Lateral Earth/Water Pressure and Drainage 24.2 Sliding, Overturning, Bearing, and Global Stability 24.3 Concrete Cantilever, Gravity, and Basement Walls 24.4 Sheet-Pile, Anchored, and Mechanically Stabilized Earth Walls

Bolted Steel Connections

Key Takeaways Explain This Topic AI

Bearing-type and slip-critical connections describe different load-transfer and service requirements; slip resistance is not the same as bolt shear strength

Bolt shear, bolt tension, and their interaction depend on bolt properties, threads, shear planes, pretension where required, and load eccentricity

Connected plates require separate checks for hole bearing, tearout, gross yielding, net-section rupture, and block shear even when bolts pass

Eccentric bolt groups combine direct force with moment-induced bolt forces vectorially rather than dividing total load equally

For a 2026 exam, use AISC Steel Construction Manual, 15th edition, and the active PE Civil handbook without importing later connection provisions

Last updated: July 2026

Bolted Steel Connections

Check both sides of the hole: A bolt can have adequate shear and tension strength while the connected plate fails in bearing, tearout, net-section rupture, or block shear. A slip requirement is another distinct check.

Bearing-Type and Slip-Critical Behavior

In a bearing-type connection, load transfer at ultimate strength can involve bolt shear and contact between bolt shank and hole. Connected material must resist bearing deformation and tearout. The connection may experience some slip before bearing develops, subject to the actual hole and fabrication conditions.

A slip-critical connection uses pretensioned bolts and friction across prepared faying surfaces to resist slip at the required limit state. Slip resistance depends on pretension, number of slip planes, surface condition, hole type, fillers, and applicable factors. Passing slip does not waive bolt shear/tension or connected-material strength checks required for the connection. Conversely, passing bearing strength does not satisfy a project requirement that slip be prevented.

  • Limit state Resisting feature Geometry/detail that matters
  • Bolt shear Bolt cross-section and shear planes Threads in/out of plane, number of planes
  • Bolt tension Bolt tensile area/strength Pretension, prying, combined force
  • Slip Clamping friction at faying surface Surface class, pretension, hole type
  • Bearing/tearout Connected plate at hole and edge Thickness, hole, spacing, edge distance
  • Block shear Plate block around bolt group Gross/net shear and net tension paths

Use AISC Steel Construction Manual, 15th edition, for a 2026 exam. Do not use later bolt tables or provisions.

Bolt Shear, Tension, and Interaction

Determine whether each bolt is in single or double shear and whether threads are included in a shear plane. Divide concentric load only when bolt stiffness and geometry justify equal force. For tension connections, include direct tension and any prying action created by flexible end plates, tees, or angles. When shear and tension occur together, apply the AISC interaction rule rather than checking each at 100% independently.

The number of bolts times one-bolt resistance is valid only when all bolts participate as assumed and spacing, deformation, long-joint, grip, and related provisions are satisfied. Connection deformation and fit-up can affect distribution.

Worked Four-Bolt Connection

A four-bolt bearing-type connection carries factored shear V_u = 240 kips . The problem supplies design bolt shear resistance 70 kips/bolt , design connected-plate bearing/tearout resistance 65 kips/bolt , and—if slip-critical behavior is required—design slip resistance 45 kips/bolt .

  • Bolt shear design resistance is
  • 4(70) = 280 kips ,

so the bolt-shear ratio is 240/280 = 0.857 and this check passes.

  • Plate bearing/tearout resistance is
  • 4(65) = 260 kips ,

so its ratio is 240/260 = 0.923 and this stated check passes.

Now check block shear of the plate. Let problem-given properties be F_y = 50 ksi , F_u = 65 ksi , gross shear area A_gv = 6.0 in² , net shear area A_nv = 4.8 in² , net tension area A_nt = 1.5 in² , and U_bs = 1.0 . The AISC nominal block-shear expression is the lesser of

  • 0.6F_uA_nv + U_bsF_uA_nt
  • and

0.6F_yA_gv + U_bsF_uA_nt .

  • The two values are
  • 0.6(65)(4.8) + 1.0(65)(1.5) = 284.7 kips
  • and

0.6(50)(6.0) + 1.0(65)(1.5) = 277.5 kips .

Thus R_n = 277.5 kips . With problem-given φ = 0.75 , design block-shear strength is

φR_n = 0.75(277.5) = 208.1 kips < 240 kips .

Block shear governs and the strength design fails even though bolt shear and hole bearing pass. If slip-critical behavior is required, 4(45) = 180 kips < 240 kips , so the stated slip check also fails. Do not add the 208.1-kip block-shear resistance to the 280-kip bolt resistance; they are alternative links in one series load path.

Connected-Material Limit States

Trace possible failure paths on a sketch. Check gross-section yielding away from holes, net-section rupture through holes with the applicable effective-net-area treatment, bearing and tearout at each hole, and block shear around the group. Hole size deductions, stagger, edge distance, pitch, plate thickness, and load direction alter the paths. Gusset yielding/buckling, local connection eccentricity, and the supported member's own limit states may also govern.

A larger or stronger bolt can worsen plate bearing demand concentration unless plate geometry changes. Adding bolts can create a longer joint, smaller edge distance, or a new weak block path. Recalculate rather than assuming bolt count alone improves every limit state.

Eccentric Bolt Groups

A load whose line of action misses the bolt-group centroid creates direct force plus moment M = Pe . Under an elastic group method, direct shear is distributed to bolts and the torsional component is proportional to bolt distance from the group centroid, with direction tangent to that radius. Vectorially add direct and torsional components at each bolt; the farthest bolt is not automatically critical when directions cancel at one side and reinforce at another.

A reliable workflow is:

Locate the bolt-group centroid from actual bolt coordinates.

Resolve applied load and compute eccentric moment about that centroid.

Distribute direct force under the selected method.

Calculate moment-induced forces using the applicable elastic or instantaneous-center method.

Vector-sum force at every bolt and check shear/tension interaction.

Use resulting hole forces for connected-material and slip checks.

Detailing and Final Audit

Confirm bolt grade/diameter, hole type, installation and pretension requirements, faying-surface condition, washers, access, edge distances, spacing, and corrosion/fire environment. Then check the load path into both connected members.

Before selecting an answer, list four separate capacities: bolt , slip if required , hole bearing/tearout , and plate paths . The smallest compatible resistance governs; success of one list item says nothing automatic about the others.