Study guide

18.3 Concrete Columns and Bearing Walls

PE Civil: Structural Exam

Track your progress as you read

Finished sections get a check mark.

1 Exam Identity and Reference Workflow

2026 PE Civil: Structural Identity, Format, and Scoring Electronic Handbook, Design Standards, Units, and Version Control

2 Chapter 2: Gravity and Construction Loads

2.1 Dead Loads and Self-Weight 2.2 Live Loads, Reduction, and Load Placement 2.3 Construction-Stage Loads

3 Environmental Loads

Wind Loads and Pressure Paths Seismic Loads and Lateral Force Distribution Snow, Rain, and Ice Loads

4 Moving, Impact, and Lateral Soil Loads

Vehicular, Crane, and Other Moving Loads Impact and Dynamic Allowances Earth Pressure and Surcharge Loads

5 Chapter 5: Load Paths and Combinations

5.1 Tributary Areas and Complete Vertical/Lateral Load Paths 5.2 Strength and Service Load Combinations

6 Reactions, Diagrams, and Basic Axial Effects

Free-Body Diagrams, Reactions, Shear, and Moment Qualitative Diagrams, Influence Lines, and Critical Placement Axial Tension, Compression, and Deformation

7 Chapter 7: Axial Systems and Shear Effects

7.1 Trusses, Braces, and Column Axial Force 7.2 Shear Stress, Shear Flow, and Built-Up Sections 7.3 One-Way, Two-Way, Punching, and Interface Shear Effects

8 Flexure

Section Properties and Elastic Flexural Stress Beam and Slab Flexural Load Effects Biaxial and Unsymmetrical Flexure

9 Combined Stress and Deflection

Combined Axial and Flexural Stress Principal Stress, Mohr's Circle, and Combined Shear Elastic Deflection Methods

10 Chapter 10: Serviceability, Torsion, and Stability

10.1 Serviceability: Deflection, Drift, Vibration, and Ponding 10.2 Torsion and Warping Effects 10.3 Buckling, Effective Length, and Second-Order Stability

11 Fatigue, Robustness, Thermal, and Bearing Effects

Fatigue and Progressive-Collapse Concepts Thermal Deformation and Bearing/Contact Stress

12 Inspections, Submittals, and Adjacent Facilities

Special Inspections and Verification Duties Shop Drawings, Submittals, RFIs, and Delegated Design Construction Effects on Adjacent Facilities

13 Chapter 13: Temporary Works and Safety

13.1 Formwork, Falsework, Scaffolding, Shoring/Reshoring, Bracing, and Anchorage 13.2 Construction, Roadside, and Work-Zone Safety

14 Soils and Core Concrete Properties

Soil Phase Relationships and Classification Soil Strength, Permeability, and Compressibility Fresh and Hardened Concrete Properties

15 Chapter 15: Prestressed Concrete and Steel Properties

15.1 Reinforced, Precast, Pretensioned, and Post-Tensioned Concrete Materials 15.2 Structural and Cold-Formed Steel Properties 15.3 Steel Toughness, Weldability, Corrosion, and Temperature Effects

16 Timber, Masonry, and Material Conformance

Timber Properties and ASD Design Values Masonry, CMU, Mortar, Grout, and Brick Veneer Properties Concrete and Masonry Test Methods Steel, Timber, and Other Material Specification Conformance

17 Horizontal Members I

Steel Beams and Girders Reinforced Concrete Beams and Slabs Timber and Masonry Horizontal Members

18 Chapter 18: Diaphragms and Vertical Members

18.1 Diaphragms, Collectors, Struts, and Composite Slabs 18.2 Steel Columns and Beam-Columns 18.3 Concrete Columns and Bearing Walls

19 Shear Walls, Trusses, and Frames

Shear Walls and Vertical Lateral Members Trusses and Braced Systems Moment Frames and Stability Systems

20 Composite/Bridge Systems and Bolted Connections

Composite Construction and Structural System Selection Bridge Systems and Load Distribution Bolted Steel Connections

21 Chapter 21: Welded, Embedded, and Anchored Connections

21.1 Welded Steel Connections 21.2 Bearing, Embedded, and Precast Connections 21.3 Anchors, Post-Installed Anchors, and Wood/Masonry Connections

22 Shallow Foundations

Isolated, Spread, and Strip Footings Combined and Strap Footings Mat Foundations and Foundation Slabs

23 Deep Foundations

Driven Piles: Axial Capacity and Settlement Drilled Shafts, Piers, and Caissons Pile Groups, Caps, and Lateral Deep-Foundation Response

24 Chapter 24: Retaining Structures

24.1 Lateral Earth/Water Pressure and Drainage 24.2 Sliding, Overturning, Bearing, and Global Stability 24.3 Concrete Cantilever, Gravity, and Basement Walls 24.4 Sheet-Pile, Anchored, and Mechanically Stabilized Earth Walls

18.3 Concrete Columns and Bearing Walls

Key Takeaways Explain This Topic AI

Concrete column design is an axial-flexural interaction problem even when loading is described as concentric; code axial limits, construction eccentricity, and frame moments remain relevant.

Longitudinal bars provide axial and flexural resistance, while ties or spirals restrain bars and confine the core through different detailing and behavior.

Slenderness and second-order effects depend on unsupported length, end and frame restraint, cracked effective stiffness, sustained load, and sway classification—not gross dimensions alone.

Concrete and masonry bearing walls require material-specific ACI 318-14 or TMS 402/602-16 checks for axial load, eccentricity, out-of-plane bending, slenderness, openings, and reinforcement.

Average P/A_g stress is a diagnostic value, not a replacement for interaction strength, minimum reinforcement, detailing, stability, or concentrated bearing checks.

Last updated: July 2026

Vertical concrete members carry gravity force, frame moment, lateral effects, and construction eccentricity into foundations. A bearing wall spreads load along length but can still bend, buckle, or concentrate force around openings. For July 2026, use the April 2024 PE Civil: Structural specification , current PE Civil Reference Handbook, ACI 318-14 , and TMS 402/602-16 for masonry. Do not import April 2027 editions.

Concrete Columns: Axial Load Plus Moment

A reinforced concrete column combines a concrete compression region with longitudinal reinforcing bars in compression or tension. Strain compatibility and equilibrium generate a nominal axial-moment interaction curve. Near high compression, concrete crushing and code axial-strength limits govern; at lower axial load, flexural behavior becomes more tension-controlled. The strength-reduction factor and applicable design point depend on the ACI 318-14 strain and confinement context.

A load described as concentric does not justify using 0.85f'_cA_g as a design answer. Reinforcement displaces concrete area, longitudinal bars contribute force, transverse reinforcement affects confinement, and ACI places limits below an ideal perfectly concentric nominal maximum. Frame analysis, construction tolerances, beam moments, and minimum eccentric effects create bending. For biaxial columns, interaction must include moments about both axes.

Tied and Spiral Reinforcement

A tied column uses discrete closed ties and crossties to restrain longitudinal bars, confine the core, and support shear resistance. Tie spacing, bar support, hooks, and layout prevent longitudinal-bar buckling and hold the cage during construction.

A spiral column uses continuous helical reinforcement around a usually circular core. Properly detailed spiral confinement can sustain core integrity and deformation after cover spalling, which is reflected in ACI strength treatment. A loose spiral, inadequate volumetric ratio, poor anchorage, or excessive pitch does not earn that behavior. Neither ties nor spirals replace required longitudinal reinforcement, development, splices, or connection force transfer.

At lap splices, beam-column joints, corbels, and foundation interfaces, congestion and confinement can govern detailing. Column bars must develop force into the footing or next story. A strong isolated section with an inadequate splice or joint is not a complete vertical path.

Worked Eccentric-Load Stress Diagnostic

An 18 in square column carries service axial load P = 900 kips at eccentricity e = 3.0 in about one centroidal axis. Before performing an ACI strength interaction, calculate gross uncracked elastic edge stresses as a diagnostic.

  • A_g = 18(18) = 324 in^2
  • S = bh^2/6 = 18(18^2)/6 = 972 in^3
  • M = Pe = 900(3) = 2,700 kip-in

Uniform stress:

P/A_g = 900/324 = 2.778 ksi compression.

Bending stress magnitude:

M/S = 2,700/972 = 2.778 ksi

Therefore the extreme stresses are 5.556 ksi compression and zero. The eccentricity equals the rectangular kern boundary h/6 = 3.0 in in this linear uncracked model. Greater eccentricity would predict tension at one edge.

This is not an ACI capacity check. Concrete cracking, nonlinear compression, reinforcement force, factored load, φ , axial upper limits, slenderness, and interaction remain. The diagnostic does show why gross average stress P/A_g = 2.778 ksi hides the peak created by eccentricity.

Slenderness and Second-Order Effects

A slender column bows under axial load, increasing moment through P-delta ; story sidesway produces P-Delta . ACI 318-14 permits specified moment-magnification or second-order analysis routes with effective stiffness reflecting cracking, reinforcement, sustained load, and creep. Use the chosen route consistently.

Unsupported length is measured between lateral supports effective in the buckling direction; physical column height may not equal that value. End restraint and whether the frame is sway or nonsway influence moment amplification. A wall can also be slender out of plane. Gross EI used without the required reductions can understate second-order effects. Braces, slabs, or walls counted as restraints need adequate stiffness, strength, and anchorage.

Concrete Bearing Walls

A concrete bearing wall carries distributed roof or floor reactions but also sees eccentric bearing, out-of-plane wind or soil pressure, in-plane lateral force, and moments at openings. ACI wall provisions control minimum thickness or reinforcement as applicable, effective height, axial-flexural strength, and detailing. Loads over a door or window must flow through lintel and jamb regions into the wall below. Concentrated beam reactions can require local bearing or reinforcement.

Do not treat a narrow wall pier automatically as a long uniform wall; its behavior may resemble a column and its boundary conditions matter. Precast wall panels require erection bracing, bearing, connections, and diaphragm attachment before the final load path exists.

Masonry Bearing Walls

Masonry uses units, mortar, grout, and reinforcement as an assemblage governed by TMS 402/602-16 , not ACI concrete column equations. Check axial load with eccentricity, out-of-plane flexure, slenderness, effective height and thickness, reinforcement and grout placement, and connection to floors, roofs, and foundations. Openings create piers, jambs, and lintels; ungrouted cells or interrupted bond cannot be assumed to transfer reinforced forces.

Concrete and masonry may share equilibrium equations, but their design strengths, stiffness assumptions, construction tolerances, and detailing rules remain separate. A generic P/A comparison cannot replace either standard.

Vertical-Member Workflow

Trace factored axial force and biaxial moments to the foundation.

Identify material, section, ties or spiral, reinforcement, openings, and load eccentricity.

Determine unsupported lengths, sway condition, and effective stiffness.

Include required second-order effects.

Apply the compatible ACI or TMS axial-flexural and shear checks.

Verify reinforcement limits, confinement, splices, bearings, connections, and foundation transfer.

Finish by asking whether the design addressed peak stress and stability, not merely average compression.