Study guide
Reinforced Concrete Beams and Slabs
PE Civil: Structural Exam
Track your progress as you read
Finished sections get a check mark.
1 Exam Identity and Reference Workflow
2026 PE Civil: Structural Identity, Format, and Scoring Electronic Handbook, Design Standards, Units, and Version Control
2 Chapter 2: Gravity and Construction Loads
2.1 Dead Loads and Self-Weight 2.2 Live Loads, Reduction, and Load Placement 2.3 Construction-Stage Loads
3 Environmental Loads
Wind Loads and Pressure Paths Seismic Loads and Lateral Force Distribution Snow, Rain, and Ice Loads
4 Moving, Impact, and Lateral Soil Loads
Vehicular, Crane, and Other Moving Loads Impact and Dynamic Allowances Earth Pressure and Surcharge Loads
5 Chapter 5: Load Paths and Combinations
5.1 Tributary Areas and Complete Vertical/Lateral Load Paths 5.2 Strength and Service Load Combinations
6 Reactions, Diagrams, and Basic Axial Effects
Free-Body Diagrams, Reactions, Shear, and Moment Qualitative Diagrams, Influence Lines, and Critical Placement Axial Tension, Compression, and Deformation
7 Chapter 7: Axial Systems and Shear Effects
7.1 Trusses, Braces, and Column Axial Force 7.2 Shear Stress, Shear Flow, and Built-Up Sections 7.3 One-Way, Two-Way, Punching, and Interface Shear Effects
8 Flexure
Section Properties and Elastic Flexural Stress Beam and Slab Flexural Load Effects Biaxial and Unsymmetrical Flexure
9 Combined Stress and Deflection
Combined Axial and Flexural Stress Principal Stress, Mohr's Circle, and Combined Shear Elastic Deflection Methods
10 Chapter 10: Serviceability, Torsion, and Stability
10.1 Serviceability: Deflection, Drift, Vibration, and Ponding 10.2 Torsion and Warping Effects 10.3 Buckling, Effective Length, and Second-Order Stability
11 Fatigue, Robustness, Thermal, and Bearing Effects
Fatigue and Progressive-Collapse Concepts Thermal Deformation and Bearing/Contact Stress
12 Inspections, Submittals, and Adjacent Facilities
Special Inspections and Verification Duties Shop Drawings, Submittals, RFIs, and Delegated Design Construction Effects on Adjacent Facilities
13 Chapter 13: Temporary Works and Safety
13.1 Formwork, Falsework, Scaffolding, Shoring/Reshoring, Bracing, and Anchorage 13.2 Construction, Roadside, and Work-Zone Safety
14 Soils and Core Concrete Properties
Soil Phase Relationships and Classification Soil Strength, Permeability, and Compressibility Fresh and Hardened Concrete Properties
15 Chapter 15: Prestressed Concrete and Steel Properties
15.1 Reinforced, Precast, Pretensioned, and Post-Tensioned Concrete Materials 15.2 Structural and Cold-Formed Steel Properties 15.3 Steel Toughness, Weldability, Corrosion, and Temperature Effects
16 Timber, Masonry, and Material Conformance
Timber Properties and ASD Design Values Masonry, CMU, Mortar, Grout, and Brick Veneer Properties Concrete and Masonry Test Methods Steel, Timber, and Other Material Specification Conformance
17 Horizontal Members I
Steel Beams and Girders Reinforced Concrete Beams and Slabs Timber and Masonry Horizontal Members
18 Chapter 18: Diaphragms and Vertical Members
18.1 Diaphragms, Collectors, Struts, and Composite Slabs 18.2 Steel Columns and Beam-Columns 18.3 Concrete Columns and Bearing Walls
19 Shear Walls, Trusses, and Frames
Shear Walls and Vertical Lateral Members Trusses and Braced Systems Moment Frames and Stability Systems
20 Composite/Bridge Systems and Bolted Connections
Composite Construction and Structural System Selection Bridge Systems and Load Distribution Bolted Steel Connections
21 Chapter 21: Welded, Embedded, and Anchored Connections
21.1 Welded Steel Connections 21.2 Bearing, Embedded, and Precast Connections 21.3 Anchors, Post-Installed Anchors, and Wood/Masonry Connections
22 Shallow Foundations
Isolated, Spread, and Strip Footings Combined and Strap Footings Mat Foundations and Foundation Slabs
23 Deep Foundations
Driven Piles: Axial Capacity and Settlement Drilled Shafts, Piers, and Caissons Pile Groups, Caps, and Lateral Deep-Foundation Response
24 Chapter 24: Retaining Structures
24.1 Lateral Earth/Water Pressure and Drainage 24.2 Sliding, Overturning, Bearing, and Global Stability 24.3 Concrete Cantilever, Gravity, and Basement Walls 24.4 Sheet-Pile, Anchored, and Mechanically Stabilized Earth Walls
Reinforced Concrete Beams and Slabs
Key Takeaways Explain This Topic AI
Effective depth d is measured from the compression face to the centroid of tension reinforcement, not to the member bottom or clear cover
Concrete flexural design requires nominal strength plus the correct strain-based strength-reduction context before comparison with factored demand
Passing flexure does not prove shear capacity, punching resistance, bar development, splice adequacy, or required reinforcement detailing
One-way and two-way slab behavior require different analysis and reinforcement distributions, including negative reinforcement over continuous supports
For a 2026 exam, use ACI 318-14 and the PE Civil handbook active for the test date rather than later concrete-code provisions
Last updated: July 2026
Reinforced Concrete Beams and Slabs
Strength is a gate, not the finish: A beam with φM_n ≥ M_u can still be unacceptable because of shear, development, splice, minimum reinforcement, spacing, cover, deflection, or constructability.
Geometry and the Compression Block
For a singly reinforced rectangular beam under positive bending, measure effective depth d from the extreme compression face to the centroid of the tension steel. Overall depth h , distance to the bar surface, and clear cover are different dimensions. If bars occur in multiple layers, locate their combined centroid.
- Under the ACI 318-14 rectangular stress-block model, a common singly reinforced calculation is
- a = A_s f_y/(0.85f'_c b)
- and
M_n = A_s f_y(d - a/2) .
These equations do not decide the strength-reduction factor by themselves. Determine neutral-axis depth and tensile strain under the applicable ACI convention to establish whether the section is tension-controlled, in transition, or otherwise limited. Compression reinforcement in a doubly reinforced section requires strain compatibility and its actual stress; do not simply add A'_s f_y without checking whether it yields.
- Check Required quantity Frequent mistake
- Flexure M_u versus applicable φM_n Comparing M_u with nominal M_n
- One-way shear V_u versus φ(V_c + V_s) Assuming stirrups are optional after flexure passes
- Punching shear Two-way perimeter and slab/column geometry Using a beam-shear strip
- Development Available length versus required anchorage Stopping bars at the theoretical moment cutoff
- Worked Flexural Strength
A rectangular beam has b = 12 in , actual d = 21 in , A_s = 4.00 in² , f'_c = 4.0 ksi , and f_y = 60 ksi . Factored demand is M_u = 300 kip-ft . The problem states that the strain check qualifies for φ = 0.90 .
Compression-block depth is
a = 4.00(60)/[0.85(4.0)(12)] = 5.882 in .
- Nominal moment strength is
- M_n = 4.00(60)(21 - 5.882/2)
M_n = 4,334 kip-in = 361.2 kip-ft .
Design strength is
φM_n = 0.90(361.2) = 325.1 kip-ft .
The utilization is 300/325.1 = 0.923 , so flexural strength passes under the stated assumptions. Comparing 300 kip-ft directly with 361.2 kip-ft would skip φ . Using h instead of d would incorrectly enlarge the lever arm. The section still must satisfy ACI reinforcement limits and detailing.
Shear After Flexure
Concrete and transverse reinforcement contribute to nominal one-way shear resistance under the applicable ACI expressions. Use the critical section, effective depth, concrete density, longitudinal reinforcement, axial effects, and stirrup geometry required by the provision.
Suppose a separate problem-given shear check has V_u = 140 kips , calculated V_c = 120 kips , and φ_v = 0.75 . Required nominal stirrup contribution from equilibrium is at least
V_s ≥ V_u/φ_v - V_c
V_s ≥ 140/0.75 - 120 = 66.7 kips .
That result is only a required contribution. Select stirrup area, strength, legs, and spacing using ACI 318-14; then check minimum shear reinforcement, maximum spacing, maximum permitted strength, anchorage, and support regions. A calculated V_s = 0 would not automatically waive code minimums.
For slabs near columns, check two-way punching around the applicable critical perimeter. Openings, drop panels, column dimensions, edge/corner location, and unbalanced moment transfer can change demand and capacity. Beam one-way shear formulas are not a substitute.
Development, Splices, and Cutoffs
Flexural resistance exists only where reinforcement can develop the required stress. Development length depends on bar size, concrete strength, coating, top-bar condition, cover, spacing, confinement, and the applicable modification factors. Standard hooks, headed bars, or mechanical anchorage work only under their stated geometric and confinement conditions.
At a bar cutoff, extend reinforcement beyond the theoretical point as required and examine shear and crack implications. At supports, positive reinforcement may need continuity or anchorage for integrity and load reversal; negative bars require development into the support region. Lap-splice location, class, staggering, and confinement matter. Congested bars that cannot be placed with cover and spacing shown are not a valid detail.
Beam and Slab Behavior
A one-way slab primarily spans between two opposite support lines and can be analyzed as strips with actual continuity. A two-way slab distributes moment in two directions; use an ACI-permitted analysis method and distribute moment to the prescribed regions. Gravity loading typically produces bottom tension in positive midspan regions and top tension over continuous supports. Provide shrinkage-and-temperature reinforcement, edge/corner detailing, and support reinforcement as required rather than reinforcing only the largest positive strip moment.
Deflection checks may require immediate and long-term stiffness, cracking, sustained load, creep, shrinkage, and compression reinforcement. Strength-level M_u is not the service-load input for every deflection expression.
Complete ACI Workflow
Establish factored demands and service effects from the actual support/slab model.
Draw bars and calculate actual d ; identify singly or doubly reinforced behavior.
Calculate M_n , tensile strain, applicable φ , and reinforcement limits.
Check one-way shear and, for slabs, punching shear.
Develop every required bar and design splices, cutoffs, hooks, and support anchorage.
Check minimum reinforcement, cover, spacing, crack control, and service deflection.
Verify the load path through bearings, joints, columns, and walls.
Do not import a later ACI edition's equation or detailing rule into a 2026 solution.