Study guide
Free-Body Diagrams, Reactions, Shear, and Moment
PE Civil: Structural Exam
Track your progress as you read
Finished sections get a check mark.
1 Exam Identity and Reference Workflow
2026 PE Civil: Structural Identity, Format, and Scoring Electronic Handbook, Design Standards, Units, and Version Control
2 Chapter 2: Gravity and Construction Loads
2.1 Dead Loads and Self-Weight 2.2 Live Loads, Reduction, and Load Placement 2.3 Construction-Stage Loads
3 Environmental Loads
Wind Loads and Pressure Paths Seismic Loads and Lateral Force Distribution Snow, Rain, and Ice Loads
4 Moving, Impact, and Lateral Soil Loads
Vehicular, Crane, and Other Moving Loads Impact and Dynamic Allowances Earth Pressure and Surcharge Loads
5 Chapter 5: Load Paths and Combinations
5.1 Tributary Areas and Complete Vertical/Lateral Load Paths 5.2 Strength and Service Load Combinations
6 Reactions, Diagrams, and Basic Axial Effects
Free-Body Diagrams, Reactions, Shear, and Moment Qualitative Diagrams, Influence Lines, and Critical Placement Axial Tension, Compression, and Deformation
7 Chapter 7: Axial Systems and Shear Effects
7.1 Trusses, Braces, and Column Axial Force 7.2 Shear Stress, Shear Flow, and Built-Up Sections 7.3 One-Way, Two-Way, Punching, and Interface Shear Effects
8 Flexure
Section Properties and Elastic Flexural Stress Beam and Slab Flexural Load Effects Biaxial and Unsymmetrical Flexure
9 Combined Stress and Deflection
Combined Axial and Flexural Stress Principal Stress, Mohr's Circle, and Combined Shear Elastic Deflection Methods
10 Chapter 10: Serviceability, Torsion, and Stability
10.1 Serviceability: Deflection, Drift, Vibration, and Ponding 10.2 Torsion and Warping Effects 10.3 Buckling, Effective Length, and Second-Order Stability
11 Fatigue, Robustness, Thermal, and Bearing Effects
Fatigue and Progressive-Collapse Concepts Thermal Deformation and Bearing/Contact Stress
12 Inspections, Submittals, and Adjacent Facilities
Special Inspections and Verification Duties Shop Drawings, Submittals, RFIs, and Delegated Design Construction Effects on Adjacent Facilities
13 Chapter 13: Temporary Works and Safety
13.1 Formwork, Falsework, Scaffolding, Shoring/Reshoring, Bracing, and Anchorage 13.2 Construction, Roadside, and Work-Zone Safety
14 Soils and Core Concrete Properties
Soil Phase Relationships and Classification Soil Strength, Permeability, and Compressibility Fresh and Hardened Concrete Properties
15 Chapter 15: Prestressed Concrete and Steel Properties
15.1 Reinforced, Precast, Pretensioned, and Post-Tensioned Concrete Materials 15.2 Structural and Cold-Formed Steel Properties 15.3 Steel Toughness, Weldability, Corrosion, and Temperature Effects
16 Timber, Masonry, and Material Conformance
Timber Properties and ASD Design Values Masonry, CMU, Mortar, Grout, and Brick Veneer Properties Concrete and Masonry Test Methods Steel, Timber, and Other Material Specification Conformance
17 Horizontal Members I
Steel Beams and Girders Reinforced Concrete Beams and Slabs Timber and Masonry Horizontal Members
18 Chapter 18: Diaphragms and Vertical Members
18.1 Diaphragms, Collectors, Struts, and Composite Slabs 18.2 Steel Columns and Beam-Columns 18.3 Concrete Columns and Bearing Walls
19 Shear Walls, Trusses, and Frames
Shear Walls and Vertical Lateral Members Trusses and Braced Systems Moment Frames and Stability Systems
20 Composite/Bridge Systems and Bolted Connections
Composite Construction and Structural System Selection Bridge Systems and Load Distribution Bolted Steel Connections
21 Chapter 21: Welded, Embedded, and Anchored Connections
21.1 Welded Steel Connections 21.2 Bearing, Embedded, and Precast Connections 21.3 Anchors, Post-Installed Anchors, and Wood/Masonry Connections
22 Shallow Foundations
Isolated, Spread, and Strip Footings Combined and Strap Footings Mat Foundations and Foundation Slabs
23 Deep Foundations
Driven Piles: Axial Capacity and Settlement Drilled Shafts, Piers, and Caissons Pile Groups, Caps, and Lateral Deep-Foundation Response
24 Chapter 24: Retaining Structures
24.1 Lateral Earth/Water Pressure and Drainage 24.2 Sliding, Overturning, Bearing, and Global Stability 24.3 Concrete Cantilever, Gravity, and Basement Walls 24.4 Sheet-Pile, Anchored, and Mechanically Stabilized Earth Walls
Free-Body Diagrams, Reactions, Shear, and Moment
Key Takeaways Explain This Topic AI
Isolate the correct body and replace every support or connection with only the force and moment components its idealization can develop
Replace a distributed load by its area acting through its centroid when solving reactions, but retain the load function when constructing internal-force diagrams
Declare one sign convention and make the free-body diagram, equilibrium equations, cut forces, and plotted ordinates agree with it
Use dV/dx = -w and dM/dx = V to check diagram slopes and curvature rather than trusting arithmetic alone
Point forces create jumps in shear, applied couples create jumps in moment, and boundary conditions provide decisive endpoint checks
- Close every solution with force balance, moment balance, diagram jumps, and diagram-area checks
- Last updated: July 2026
Free-Body Diagrams, Reactions, Shear, and Moment
For a July 2026 PE Civil: Structural problem, use the current NCEES PE Civil Reference Handbook supplied for the test date . Diagram mechanics are governed by equilibrium, but the handbook controls notation and formulas available during the CBT exam. A plausible number is not enough: its free-body diagram, units, and signs must describe the same physical system.
Start with the body and its supports
A free-body diagram isolates one body from its surroundings. Show all applied loads, dimensions, axes, and the actions exerted by removed supports or connected bodies. In a two-dimensional idealization:
- Support Usual reaction components Released action
- Roller on a smooth surface One force normal to the surface Tangential force and moment
- Pin Two force components Moment
- Fixed support Two force components and one couple None
- Internal hinge Force components transmitted between pieces Bending moment at the hinge
Do not add a horizontal reaction to a frictionless horizontal roller or a moment to a pin merely to make the equations work. Conversely, a fixed support can develop a reaction couple even when the applied loading is vertical. If an internal hinge divides a structure, draw separate free bodies when its zero-moment condition supplies useful information. Equal-and-opposite hinge forces appear on the two pieces.
Count unknown reactions only after idealizing the supports. Then choose a convenient origin and declare positive directions. For a planar body, use ΣFx = 0 , ΣFy = 0 , and ΣM = 0 . Taking moments about a point through multiple unknown forces often eliminates them. A negative result does not mean failure; it means the actual reaction acts opposite the assumed arrow.
Distributed loads and internal cuts
For external equilibrium, replace a distributed load w(x) by its resultant W = ∫w(x) dx acting at the centroid of the load diagram. A uniform load w over length L becomes wL at midlength. A triangular load has area wmax L/2 and acts one-third of the base length from its larger end. Keep force-per-length units distinct from force. For a trapezoid or piecewise load, split the loading into simple shapes, sum their areas, and locate the combined resultant from first moments. Verify that its line of action lies within the loaded interval.
To find internal actions, cut the member at coordinate x and isolate either side. Expose axial force N , shear V , and bending moment M . This section uses tension-positive N , positive shear consistent with dM/dx = V , and positive sagging moment. Another convention is acceptable only if every equation and diagram follows it. Forces on opposite faces of the cut must be equal and opposite.
With downward distributed load defined as positive w , the differential checks are
dV/dx = -w(x) and dM/dx = V(x) .
Therefore no distributed load gives constant shear and linear moment; uniform load gives linear shear and parabolic moment; linearly varying load gives parabolic shear and cubic moment. A downward point load causes a downward jump in V equal to its magnitude. An applied concentrated couple causes a jump in M ; a point force alone does not. A local maximum or minimum of a smooth moment diagram usually occurs where V = 0 .
Worked beam from reactions through diagrams
A simply supported 20-ft beam has a pin at A , a roller at B , a uniform downward load of 1.2 kip/ft over the full span, and an 8-kip downward point load 6 ft from A . The uniform-load resultant is 1.2(20) = 24 kip at 10 ft. No horizontal load exists, so Ax = 0 .
- Taking moments about A ,
- By(20) - 24(10) - 8(6) = 0 ,
so By = 14.4 kip . Vertical equilibrium gives Ay = 24 + 8 - 14.4 = 17.6 kip . Both are upward.
- For 0 < x < 6 ft ,
- V(x) = 17.6 - 1.2x ,
- so V(6-) = 10.4 kip . The point load produces an 8-kip downward jump: V(6+) = 2.4 kip . For 6 < x < 20 ft ,
V(x) = 17.6 - 1.2x - 8 = 9.6 - 1.2x .
Thus V = 0 at x = 8 ft , and V(20-) = -14.4 kip . The upward reaction at B jumps shear back to zero. The net change from the distributed load, point load, and both reactions is zero, matching vertical equilibrium.
- Using sagging moment as positive and the left segment,
- for 0 ≤ x ≤ 6 , M(x) = 17.6x - 1.2x²/2 ;
for 6 ≤ x ≤ 20 , M(x) = 17.6x - 1.2x²/2 - 8(x - 6) .
The moment is continuous at the point load: M(6) = 84.0 kip-ft . At the zero-shear location, M(8) = 86.4 kip-ft , the maximum. At the simple support, M(20) = 0 , as required. The moment curve is parabolic throughout because the uniform load remains present, while its slope changes continuously with shear.
Fast reliability checks
Before selecting an answer, verify:
Reactions plus applied forces balance in each direction, and moments balance about an independent point.
The shear jump at each point force equals that force with sign.
The change in moment between two locations equals the signed area under the shear diagram.
Diagram slopes and curvature match w , V , and M .
Pin and roller end moments are zero unless an external end couple is applied; a fixed end need not be zero.
Units progress correctly from kip/ft to kip to kip-ft .
These checks make the sketch a second solution, not decoration.