Study guide
24.2 Sliding, Overturning, Bearing, and Global Stability
PE Civil: Structural Exam
Track your progress as you read
Finished sections get a check mark.
1 Exam Identity and Reference Workflow
2026 PE Civil: Structural Identity, Format, and Scoring Electronic Handbook, Design Standards, Units, and Version Control
2 Chapter 2: Gravity and Construction Loads
2.1 Dead Loads and Self-Weight 2.2 Live Loads, Reduction, and Load Placement 2.3 Construction-Stage Loads
3 Environmental Loads
Wind Loads and Pressure Paths Seismic Loads and Lateral Force Distribution Snow, Rain, and Ice Loads
4 Moving, Impact, and Lateral Soil Loads
Vehicular, Crane, and Other Moving Loads Impact and Dynamic Allowances Earth Pressure and Surcharge Loads
5 Chapter 5: Load Paths and Combinations
5.1 Tributary Areas and Complete Vertical/Lateral Load Paths 5.2 Strength and Service Load Combinations
6 Reactions, Diagrams, and Basic Axial Effects
Free-Body Diagrams, Reactions, Shear, and Moment Qualitative Diagrams, Influence Lines, and Critical Placement Axial Tension, Compression, and Deformation
7 Chapter 7: Axial Systems and Shear Effects
7.1 Trusses, Braces, and Column Axial Force 7.2 Shear Stress, Shear Flow, and Built-Up Sections 7.3 One-Way, Two-Way, Punching, and Interface Shear Effects
8 Flexure
Section Properties and Elastic Flexural Stress Beam and Slab Flexural Load Effects Biaxial and Unsymmetrical Flexure
9 Combined Stress and Deflection
Combined Axial and Flexural Stress Principal Stress, Mohr's Circle, and Combined Shear Elastic Deflection Methods
10 Chapter 10: Serviceability, Torsion, and Stability
10.1 Serviceability: Deflection, Drift, Vibration, and Ponding 10.2 Torsion and Warping Effects 10.3 Buckling, Effective Length, and Second-Order Stability
11 Fatigue, Robustness, Thermal, and Bearing Effects
Fatigue and Progressive-Collapse Concepts Thermal Deformation and Bearing/Contact Stress
12 Inspections, Submittals, and Adjacent Facilities
Special Inspections and Verification Duties Shop Drawings, Submittals, RFIs, and Delegated Design Construction Effects on Adjacent Facilities
13 Chapter 13: Temporary Works and Safety
13.1 Formwork, Falsework, Scaffolding, Shoring/Reshoring, Bracing, and Anchorage 13.2 Construction, Roadside, and Work-Zone Safety
14 Soils and Core Concrete Properties
Soil Phase Relationships and Classification Soil Strength, Permeability, and Compressibility Fresh and Hardened Concrete Properties
15 Chapter 15: Prestressed Concrete and Steel Properties
15.1 Reinforced, Precast, Pretensioned, and Post-Tensioned Concrete Materials 15.2 Structural and Cold-Formed Steel Properties 15.3 Steel Toughness, Weldability, Corrosion, and Temperature Effects
16 Timber, Masonry, and Material Conformance
Timber Properties and ASD Design Values Masonry, CMU, Mortar, Grout, and Brick Veneer Properties Concrete and Masonry Test Methods Steel, Timber, and Other Material Specification Conformance
17 Horizontal Members I
Steel Beams and Girders Reinforced Concrete Beams and Slabs Timber and Masonry Horizontal Members
18 Chapter 18: Diaphragms and Vertical Members
18.1 Diaphragms, Collectors, Struts, and Composite Slabs 18.2 Steel Columns and Beam-Columns 18.3 Concrete Columns and Bearing Walls
19 Shear Walls, Trusses, and Frames
Shear Walls and Vertical Lateral Members Trusses and Braced Systems Moment Frames and Stability Systems
20 Composite/Bridge Systems and Bolted Connections
Composite Construction and Structural System Selection Bridge Systems and Load Distribution Bolted Steel Connections
21 Chapter 21: Welded, Embedded, and Anchored Connections
21.1 Welded Steel Connections 21.2 Bearing, Embedded, and Precast Connections 21.3 Anchors, Post-Installed Anchors, and Wood/Masonry Connections
22 Shallow Foundations
Isolated, Spread, and Strip Footings Combined and Strap Footings Mat Foundations and Foundation Slabs
23 Deep Foundations
Driven Piles: Axial Capacity and Settlement Drilled Shafts, Piers, and Caissons Pile Groups, Caps, and Lateral Deep-Foundation Response
24 Chapter 24: Retaining Structures
24.1 Lateral Earth/Water Pressure and Drainage 24.2 Sliding, Overturning, Bearing, and Global Stability 24.3 Concrete Cantilever, Gravity, and Basement Walls 24.4 Sheet-Pile, Anchored, and Mechanically Stabilized Earth Walls
24.2 Sliding, Overturning, Bearing, and Global Stability
Key Takeaways Explain This Topic AI
A retaining-wall free-body diagram must include every vertical and horizontal force, water and uplift, its line of action, and the exact soil-wall boundary used for the body.
ASD safety-factor checks and LRFD factored-load/resistance checks are separate calibrated frameworks and must not be combined in one ratio.
Passive resistance, base adhesion, key resistance, or soil over a toe can be counted only when the soil remains present and the governing provisions permit reliable mobilization.
Base resultant and eccentricity determine whether full contact exists and whether linear q_max/q_min formulas are valid; soil cannot carry tension.
Passing sliding, overturning, and bearing checks does not prove global slope stability or acceptable settlement.
Last updated: July 2026
External stability asks whether the wall-soil system slides, rotates, overstresses its foundation contact, settles, or fails along a deep surface. These are related but distinct modes. For July 2026, use the April 2024 PE Civil: Structural specification , current PE Civil Reference Handbook, AASHTO LRFD 8th edition with the listed May 2018 errata , and IBC 2018 . Do not import April 2027 standards.
Draw One Complete Free Body
Choose the body before summing forces. For a cantilever wall, an external-stability body commonly includes wall concrete and soil above the heel, but internal stem or heel design uses different cuts. Label wall and footing weights, retained soil, surcharge effects, lateral earth force, water pressure, uplift, vertical components, toe and heel locations, base width, and every lever arm.
Do not count the same soil both as weight on the heel and as an external vertical force across a cut. Water behind the wall creates horizontal load; water beneath the base can reduce effective vertical reaction and friction. If water exists in front, its direction may be stabilizing for one stage and absent after drawdown. Stage and drainage assumptions control.
- Choose ASD or LRFD Before Calculating
- In a traditional ASD service-load check, sliding factor of safety can be written
- FS_slide = ΣR/ΣD
- and overturning factor of safety
- FS_OT = ΣM_resist/ΣM_overturn
using unfactored service actions and the geotechnical safety-factor basis specified by the problem. Allowable bearing pressure and settlement criteria then use their compatible service basis.
AASHTO LRFD instead applies load combinations, load factors, resistance factors, and limit-state rules. Do not factor earth load, divide soil resistance by an ASD factor of safety, and then apply an LRFD resistance factor. That double- or mismatched treatment has no valid calibration. Use one complete framework.
Sliding Resistance
Base friction is often modeled as R_f = μN' , where N' is effective normal force after relevant uplift and μ is the permitted interface coefficient. Cohesion or adhesion needs explicit geotechnical support. A shear key changes the passive and bearing mechanism and requires structural design.
Passive soil in front of the toe is unavailable if it may be excavated for utilities, eroded, scoured, frost-disturbed, or not move enough to mobilize passive pressure. Codes or owners may limit or prohibit its use. Never add full passive resistance merely because a coefficient can be calculated.
Worked ASD External-Stability Example
A 10 ft-wide wall base is checked with service loads per foot of wall. Total effective vertical force is V = 100 kips/ft , acting 6.0 ft from the toe before lateral overturning is included. The lateral driving force is H = 20 kips/ft , acting 4.0 ft above the base. Use permitted base friction coefficient μ = 0.45 , ignore passive resistance, and use a problem-given allowable bearing pressure of 12.0 ksf.
Sliding:
- R_f = μV = 0.45(100) = 45 kips/ft
- FS_slide = 45/20 = 2.25
Overturning about the toe:
- M_resist = 100(6.0) = 600 kip-ft/ft
- M_overturn = 20(4.0) = 80 kip-ft/ft
- FS_OT = 600/80 = 7.50
Net resultant location from the toe:
x_R = (600 - 80)/100 = 5.20 ft
The resultant is 0.20 ft toward the heel from the 5.0 ft base center, so e = 0.20 ft . Because e < B/6 = 1.667 ft , full compression contact is predicted.
- Average pressure is V/B = 100/10 = 10.0 ksf . Extreme pressures are
- q_max,min = (V/B)(1 ± 6e/B)
- q_max = 10[1 + 6(0.20)/10] = 11.2 ksf
- q_min = 10[1 - 6(0.20)/10] = 8.8 ksf
The stated bearing check passes because 11.2 < 12.0 ksf ; both pressures are compressive. These results do not establish that required project safety factors are met unless their acceptance values are given, nor do they check settlement or global stability.
When the Resultant Leaves the Kern
If |e| > B/6 , the linear full-width formula predicts tension at one edge. Soil contact does not resist tension, so use the permitted partial-contact distribution and effective bearing width. Do not report negative bearing as a stabilizing tensile force. Large eccentricity can also increase settlement and rotation even when peak bearing remains below an ultimate value.
Bearing, Settlement, and Global Stability
Bearing capacity addresses a shallow shear failure beneath the base. Settlement considers compression and distortion at service load and may govern on compressible or variable soils. Check resultant direction, inclination, footing embedment, groundwater, and layered foundation soil using the geotechnical basis provided.
Global stability examines a deep slip surface passing through retained soil, foundation soil, and possibly beneath or behind the wall. A wall can have high sliding and overturning factors on its base yet move with a larger soil mass. Weak seams, sloping ground, surcharge, water, seismic stage, and adjacent excavation affect this mode. It generally requires a slope-stability analysis, not a base-friction shortcut.
Final Audit
Write ASD or LRFD at the top. Then check sliding, overturning, contact, bearing, settlement, and global stability separately. Identify every credited resistance and why it remains available for the governing stage.
A base key or anchor is not free resistance: check its structural shear and flexure, surrounding-soil failure, construction tolerance, and compatibility with the movement needed to mobilize friction or passive pressure.
External-Stability Gate Map
- Mode Governing evidence
- Sliding Available interface or passive resistance versus lateral demand
- Overturning and contact Moment equilibrium, resultant location, and compression-only bearing
- Bearing and settlement Compatible geotechnical pressure and deformation checks
- Global stability A deep slip-surface analysis through the wall-soil system