Study guide
Isolated, Spread, and Strip Footings
PE Civil: Structural Exam
Track your progress as you read
Finished sections get a check mark.
1 Exam Identity and Reference Workflow
2026 PE Civil: Structural Identity, Format, and Scoring Electronic Handbook, Design Standards, Units, and Version Control
2 Chapter 2: Gravity and Construction Loads
2.1 Dead Loads and Self-Weight 2.2 Live Loads, Reduction, and Load Placement 2.3 Construction-Stage Loads
3 Environmental Loads
Wind Loads and Pressure Paths Seismic Loads and Lateral Force Distribution Snow, Rain, and Ice Loads
4 Moving, Impact, and Lateral Soil Loads
Vehicular, Crane, and Other Moving Loads Impact and Dynamic Allowances Earth Pressure and Surcharge Loads
5 Chapter 5: Load Paths and Combinations
5.1 Tributary Areas and Complete Vertical/Lateral Load Paths 5.2 Strength and Service Load Combinations
6 Reactions, Diagrams, and Basic Axial Effects
Free-Body Diagrams, Reactions, Shear, and Moment Qualitative Diagrams, Influence Lines, and Critical Placement Axial Tension, Compression, and Deformation
7 Chapter 7: Axial Systems and Shear Effects
7.1 Trusses, Braces, and Column Axial Force 7.2 Shear Stress, Shear Flow, and Built-Up Sections 7.3 One-Way, Two-Way, Punching, and Interface Shear Effects
8 Flexure
Section Properties and Elastic Flexural Stress Beam and Slab Flexural Load Effects Biaxial and Unsymmetrical Flexure
9 Combined Stress and Deflection
Combined Axial and Flexural Stress Principal Stress, Mohr's Circle, and Combined Shear Elastic Deflection Methods
10 Chapter 10: Serviceability, Torsion, and Stability
10.1 Serviceability: Deflection, Drift, Vibration, and Ponding 10.2 Torsion and Warping Effects 10.3 Buckling, Effective Length, and Second-Order Stability
11 Fatigue, Robustness, Thermal, and Bearing Effects
Fatigue and Progressive-Collapse Concepts Thermal Deformation and Bearing/Contact Stress
12 Inspections, Submittals, and Adjacent Facilities
Special Inspections and Verification Duties Shop Drawings, Submittals, RFIs, and Delegated Design Construction Effects on Adjacent Facilities
13 Chapter 13: Temporary Works and Safety
13.1 Formwork, Falsework, Scaffolding, Shoring/Reshoring, Bracing, and Anchorage 13.2 Construction, Roadside, and Work-Zone Safety
14 Soils and Core Concrete Properties
Soil Phase Relationships and Classification Soil Strength, Permeability, and Compressibility Fresh and Hardened Concrete Properties
15 Chapter 15: Prestressed Concrete and Steel Properties
15.1 Reinforced, Precast, Pretensioned, and Post-Tensioned Concrete Materials 15.2 Structural and Cold-Formed Steel Properties 15.3 Steel Toughness, Weldability, Corrosion, and Temperature Effects
16 Timber, Masonry, and Material Conformance
Timber Properties and ASD Design Values Masonry, CMU, Mortar, Grout, and Brick Veneer Properties Concrete and Masonry Test Methods Steel, Timber, and Other Material Specification Conformance
17 Horizontal Members I
Steel Beams and Girders Reinforced Concrete Beams and Slabs Timber and Masonry Horizontal Members
18 Chapter 18: Diaphragms and Vertical Members
18.1 Diaphragms, Collectors, Struts, and Composite Slabs 18.2 Steel Columns and Beam-Columns 18.3 Concrete Columns and Bearing Walls
19 Shear Walls, Trusses, and Frames
Shear Walls and Vertical Lateral Members Trusses and Braced Systems Moment Frames and Stability Systems
20 Composite/Bridge Systems and Bolted Connections
Composite Construction and Structural System Selection Bridge Systems and Load Distribution Bolted Steel Connections
21 Chapter 21: Welded, Embedded, and Anchored Connections
21.1 Welded Steel Connections 21.2 Bearing, Embedded, and Precast Connections 21.3 Anchors, Post-Installed Anchors, and Wood/Masonry Connections
22 Shallow Foundations
Isolated, Spread, and Strip Footings Combined and Strap Footings Mat Foundations and Foundation Slabs
23 Deep Foundations
Driven Piles: Axial Capacity and Settlement Drilled Shafts, Piers, and Caissons Pile Groups, Caps, and Lateral Deep-Foundation Response
24 Chapter 24: Retaining Structures
24.1 Lateral Earth/Water Pressure and Drainage 24.2 Sliding, Overturning, Bearing, and Global Stability 24.3 Concrete Cantilever, Gravity, and Basement Walls 24.4 Sheet-Pile, Anchored, and Mechanically Stabilized Earth Walls
Isolated, Spread, and Strip Footings
Key Takeaways Explain This Topic AI
Use service or ASD load effects with geotechnical allowable bearing pressure, then use factored strength combinations for ACI 318-14 footing flexure and shear
Concentric pressure is P/A; eccentric full-contact pressure is linear and requires checking both qmax and qmin with consistent axes and signs
If an unbonded soil interface would require tension, revise the contact model rather than accepting a negative bearing pressure
For a column footing, flexure is checked at the column face, one-way shear at distance d from the face, and two-way shear on the ACI critical perimeter at d/2
Column bearing, dowels, bar development, concrete cover, base shear transfer, and reinforcement placement complete the structural load path
- Allowable bearing compliance does not prove acceptable total or differential settlement
- Last updated: July 2026
Isolated, Spread, and Strip Footings
For July 2026, use the current NCEES PE Civil Reference Handbook , ACI 318-14 , and IBC 2018 without supplements . A shallow footing has two interacting designs: soil must support the foundation without bearing or settlement failure, and the concrete footing must carry column or wall forces to that soil. The two designs normally use different load bases.
Select the footing type and load basis
An isolated footing supports one column or pedestal. A spread footing widens the load over soil and can be isolated or continuous. A strip footing runs continuously under a wall or line of closely spaced supports and is often analyzed per foot of length. Geometry also must satisfy property, frost, adjacent-foundation, excavation, and competent-bearing-elevation constraints from IBC 2018 and the geotechnical report.
IBC 2018 pairs allowable soil bearing pressures with its allowable-stress load combinations. Thus footing plan area is commonly proportioned with service or ASD reactions, including footing and overburden weight consistently with whether the geotechnical value is gross or net . Do not add footing weight to a service reaction if the stated net allowable pressure already excludes the same overburden effect.
The concrete footing's flexure, shear, bearing, and development are strength checks using ACI 318-14 and factored load effects. Do not compare factored soil pressure directly with an allowable geotechnical pressure, and do not design reinforcing steel from unfactored pressure when a strength check is requested. Keep two labeled pressure diagrams if necessary.
- Soil contact and eccentricity
- For a rigid footing with a concentric vertical service resultant P , average pressure is
q = P/A .
- If a moment M acts about a centroidal axis and full contact remains, linear elastic pressure is
- q = P/A ± M/S ,
where S is the footing contact-area section modulus about that axis. For eccentricity e = M/P along footing dimension B , full compression for a rectangular contact requires the resultant within the middle third, |e| ≤ B/6 . Check both qmax against allowable bearing and qmin ≥ 0 for a no-tension soil interface.
When qmin is negative, soil does not ordinarily pull the footing downward. Use the no-tension contact distribution required by the problem, resize the footing, add stabilizing load, or adopt a soil-structure interaction model. A triangular compression block is not obtained by simply setting a negative corner to zero while leaving the original positive corner unchanged; equilibrium must be restored.
Soil strength is not the only geotechnical criterion. Estimate total settlement and differential settlement using the report's soil profile and method. Two footings can each satisfy allowable pressure yet settle differently because their sizes, loads, layers, or construction histories differ. Rotation can also change superstructure force distribution.
Worked bearing and strength actions
A square column footing supports service dead load D = 300 kip and service live load L = 200 kip . The geotechnical report gives allowable bearing qallow = 4.0 ksf for the stated service basis, and assume footing weight is already treated consistently. Required area is
Areq = (300 + 200)/4.0 = 125 ft² .
Choose a 12 ft × 12 ft footing, A = 144 ft² . The concentric service pressure is
qservice = 500/144 = 3.47 ksf < 4.0 ksf .
- Bearing passes at this stage, subject to settlement. For a strength example, use
- Pu = 1.2D + 1.6L = 1.2(300) + 1.6(200) = 680 kip ,
- so the simplified uniform factored pressure is
qu = 680/144 = 4.72 ksf .
The column is 24 in square and effective footing depth is d = 25 in = 2.083 ft . For two-way shear, the critical perimeter lies d/2 from the column faces. Its enclosed square has side 24 + 25 = 49 in = 4.083 ft , so enclosed area is 16.67 ft² . The factored punching demand is the column force minus upward soil reaction inside that perimeter:
Vu,2way = 680 - 4.72(16.67) = 601.3 kip .
Compare this with the ACI 318-14 two-way shear strength using the actual critical perimeter, depth, concrete strength, column location, and applicable factors.
For one-way shear across the full 12-ft footing width, the critical section is d from the column face. The cantilever length beyond that section is
6 - 1 - 2.083 = 2.917 ft .
Therefore
Vu,1way = 4.72(12)(2.917) = 165.3 kip .
At the column face, the footing projection is 6 - 1 = 5 ft ; the factored cantilever moment for one side is
Mu = qu B l²/2 = 4.72(12)(5²)/2 = 708 kip-ft .
These are demands, not capacities. Select thickness and reinforcement so ACI flexure and shear strengths exceed them.
Complete the detail
Bottom reinforcement generally resists upward-soil-pressure bending in an isolated footing, but local moments, walls, or combined actions can change required faces and directions. Extend bars far enough to develop beyond the governing section; merely placing the calculated steel area at midspan is insufficient. Check column-to-footing bearing, dowels or developed column bars, pedestal interfaces, concrete cover cast against earth, and any shear-friction, key, or anchorage path for lateral force.
For a strip footing, repeat the equilibrium per unit wall length and check one-way behavior and transverse flexure under the applicable ACI model; concentrated pilasters can introduce local two-way effects. Finish by reconciling service bearing, settlement, factored structural design, and construction geometry. Passing only P/A completes none of the local concrete checks. Along a long strip footing, also examine stiffness changes and soil transitions that can concentrate differential movement beneath the supported wall.
Foundation Gate Map
- Gate Compatible basis
- Allowable bearing and settlement Service or ASD reactions and geotechnical definitions
- Flexure and one-way or two-way shear Factored pressure and ACI 318-14 strength design
- Contact and eccentricity Force and moment equilibrium with no unbonded soil tension
- Detailing Development, dowels, cover, joints, and constructible geometry