Study guide

Timber Properties and ASD Design Values

PE Civil: Structural Exam

Track your progress as you read

Finished sections get a check mark.

1 Exam Identity and Reference Workflow

2026 PE Civil: Structural Identity, Format, and Scoring Electronic Handbook, Design Standards, Units, and Version Control

2 Chapter 2: Gravity and Construction Loads

2.1 Dead Loads and Self-Weight 2.2 Live Loads, Reduction, and Load Placement 2.3 Construction-Stage Loads

3 Environmental Loads

Wind Loads and Pressure Paths Seismic Loads and Lateral Force Distribution Snow, Rain, and Ice Loads

4 Moving, Impact, and Lateral Soil Loads

Vehicular, Crane, and Other Moving Loads Impact and Dynamic Allowances Earth Pressure and Surcharge Loads

5 Chapter 5: Load Paths and Combinations

5.1 Tributary Areas and Complete Vertical/Lateral Load Paths 5.2 Strength and Service Load Combinations

6 Reactions, Diagrams, and Basic Axial Effects

Free-Body Diagrams, Reactions, Shear, and Moment Qualitative Diagrams, Influence Lines, and Critical Placement Axial Tension, Compression, and Deformation

7 Chapter 7: Axial Systems and Shear Effects

7.1 Trusses, Braces, and Column Axial Force 7.2 Shear Stress, Shear Flow, and Built-Up Sections 7.3 One-Way, Two-Way, Punching, and Interface Shear Effects

8 Flexure

Section Properties and Elastic Flexural Stress Beam and Slab Flexural Load Effects Biaxial and Unsymmetrical Flexure

9 Combined Stress and Deflection

Combined Axial and Flexural Stress Principal Stress, Mohr's Circle, and Combined Shear Elastic Deflection Methods

10 Chapter 10: Serviceability, Torsion, and Stability

10.1 Serviceability: Deflection, Drift, Vibration, and Ponding 10.2 Torsion and Warping Effects 10.3 Buckling, Effective Length, and Second-Order Stability

11 Fatigue, Robustness, Thermal, and Bearing Effects

Fatigue and Progressive-Collapse Concepts Thermal Deformation and Bearing/Contact Stress

12 Inspections, Submittals, and Adjacent Facilities

Special Inspections and Verification Duties Shop Drawings, Submittals, RFIs, and Delegated Design Construction Effects on Adjacent Facilities

13 Chapter 13: Temporary Works and Safety

13.1 Formwork, Falsework, Scaffolding, Shoring/Reshoring, Bracing, and Anchorage 13.2 Construction, Roadside, and Work-Zone Safety

14 Soils and Core Concrete Properties

Soil Phase Relationships and Classification Soil Strength, Permeability, and Compressibility Fresh and Hardened Concrete Properties

15 Chapter 15: Prestressed Concrete and Steel Properties

15.1 Reinforced, Precast, Pretensioned, and Post-Tensioned Concrete Materials 15.2 Structural and Cold-Formed Steel Properties 15.3 Steel Toughness, Weldability, Corrosion, and Temperature Effects

16 Timber, Masonry, and Material Conformance

Timber Properties and ASD Design Values Masonry, CMU, Mortar, Grout, and Brick Veneer Properties Concrete and Masonry Test Methods Steel, Timber, and Other Material Specification Conformance

17 Horizontal Members I

Steel Beams and Girders Reinforced Concrete Beams and Slabs Timber and Masonry Horizontal Members

18 Chapter 18: Diaphragms and Vertical Members

18.1 Diaphragms, Collectors, Struts, and Composite Slabs 18.2 Steel Columns and Beam-Columns 18.3 Concrete Columns and Bearing Walls

19 Shear Walls, Trusses, and Frames

Shear Walls and Vertical Lateral Members Trusses and Braced Systems Moment Frames and Stability Systems

20 Composite/Bridge Systems and Bolted Connections

Composite Construction and Structural System Selection Bridge Systems and Load Distribution Bolted Steel Connections

21 Chapter 21: Welded, Embedded, and Anchored Connections

21.1 Welded Steel Connections 21.2 Bearing, Embedded, and Precast Connections 21.3 Anchors, Post-Installed Anchors, and Wood/Masonry Connections

22 Shallow Foundations

Isolated, Spread, and Strip Footings Combined and Strap Footings Mat Foundations and Foundation Slabs

23 Deep Foundations

Driven Piles: Axial Capacity and Settlement Drilled Shafts, Piers, and Caissons Pile Groups, Caps, and Lateral Deep-Foundation Response

24 Chapter 24: Retaining Structures

24.1 Lateral Earth/Water Pressure and Drainage 24.2 Sliding, Overturning, Bearing, and Global Stability 24.3 Concrete Cantilever, Gravity, and Basement Walls 24.4 Sheet-Pile, Anchored, and Mechanically Stabilized Earth Walls

Timber Properties and ASD Design Values

Key Takeaways Explain This Topic AI

Use the 2018 NDS and Supplement with ASD only for wood questions on the July 2026 PE Civil: Structural exam

Select reference design values from the actual product, species or species group, grade, size, and use orientation before applying adjustments

Apply only the NDS adjustment factors listed for the specific property being checked; one common multiplier does not adjust every value

Load duration, wet service, temperature, size, repetitive-member action, incising, and stability describe different physical effects

Repetitive-member benefit requires a qualifying group and load-distributing element; merely placing two pieces nearby is insufficient

Engineered wood strength axes, layup orientation, manufacturer data, and product-specific NDS provisions must match the installed direction

Last updated: July 2026

Timber Properties and ASD Design Values

For the July 2026 PE Civil: Structural exam, wood design is ASD only . Use the 2018 NDS and Supplement , the 2015 SDPWS where a lateral system is involved, and the current NCEES PE Civil Reference Handbook. Do not import NDS LRFD format-conversion, resistance, or time-effect factors, and do not substitute a later NDS edition.

Reference values begin with identity

Wood is orthotropic and naturally variable. A reference value is not selected by nominal dimensions alone. Establish:

  • Input Why it matters
  • Product type Sawn lumber, glulam, structural composite lumber, and panels use different tables or product data
  • Species or species group Cellular structure and grading population affect strength and stiffness
  • Grade Visual or mechanical grading limits defects and assigns a value set
  • Size and orientation Actual section properties, size effects, and strong/weak axes change response
  • Service condition Moisture and temperature can modify applicable values
  • Structural use Beam, column, tension member, bearing, connection, or diaphragm requires different properties

For sawn lumber, common reference values include bending Fb , tension parallel to grain Ft , shear parallel to grain Fv , compression perpendicular Fc⊥ , compression parallel Fc , modulus E , and stability modulus Emin . They answer different limit states. Do not use Fb to check bearing or use average E where the NDS stability procedure calls for Emin .

Nominal size identifies the commercial member; stress calculations use actual dressed dimensions unless the problem states otherwise. A 2×10 is not 2 in by 10 in. Species, grade, and seasoning marks must agree with the specified member rather than being inferred from appearance.

  • ASD adjustment workflow
  • Write an adjusted value as

F' = F × (product of factors applicable to that property) .

Use the 2018 NDS applicability table, not one memorized string. Important factors include:

CD , load duration, for the ASD properties to which the table assigns it; it does not generally adjust E or compression perpendicular to grain;

  • CM , wet service, whose value depends on the property and tabulated conditions;
  • Ct , elevated-temperature service;
  • CF , size, where applicable to dimension lumber values;
  • Cfu , flat use, when bending orientation triggers it;
  • Ci , incising, for affected properties of incised lumber;
  • Cr , repetitive member, for qualifying bending members;

CL , beam stability, and CP , column stability, determined from bracing and slenderness rather than chosen as generic environmental factors;

Cb , bearing area, for eligible compression-perpendicular checks.

A factor absent from the property's row does not become applicable because its name sounds relevant. Determine the governing ASD load combination and its permitted CD ; then apply moisture, temperature, geometry, treatment, system, and stability factors required for that property. Compare the stress or force effect from the same ASD load basis with the adjusted allowable value or capacity.

Load duration and repetitive action

The reference condition corresponds to normal load duration. Shorter-duration maximum loads can permit a larger adjusted strength through CD , while permanent loading does not receive that benefit. Determine duration from the load causing the maximum combined stress, not from the project calendar. CD changes allowable strength for eligible properties; it does not reduce calculated load.

For sawn-lumber bending, Cr recognizes load sharing among three or more qualifying parallel members, in contact or spaced no more than 24 in on center, connected by a floor, roof, or other load-distributing element adequate to support the design load. A single beam, isolated header, or pair of joists does not qualify merely because similar lumber exists elsewhere. Engineered products use their applicable NDS or manufacturer provisions rather than automatically inheriting the sawn-lumber factor.

Worked adjusted bending value

A repetitive floor-joist problem gives reference Fb = 1,000 psi . The stated applicable factors are CD = 1.15 , CM = 0.85 , CF = 1.10 , Cr = 1.15 , and CL = 1.00 ; all other applicable factors are 1.0. Then

Fb' = 1,000(1.15)(0.85)(1.10)(1.15)(1.00) = 1,237 psi .

For an actual 1.5 in × 9.25 in rectangular joist,

S = bd²/6 = 1.5(9.25²)/6 = 21.39 in³ .

The ASD bending moment corresponding to this stress check is

Mallow = Fb'S = 1,237(21.39) = 26,460 lb-in = 2.21 kip-ft .

If analysis gives M = 2.00 kip-ft , the bending stress is 2.00(12)(1,000)/21.39 = 1,122 psi , which is less than Fb' ; this bending check passes. That result does not complete shear, bearing, deflection, connection, or stability checks.

Do not apply Cr unless the stated joist group and sheathing meet its conditions. Do not apply CD again to the 2.00-kip-ft demand. The factors adjust the allowable property once.

Moisture, orientation, and engineered wood

Wet service is not synonymous with rain during construction. Use NDS service-condition definitions and the property's tabulated CM ; bending, compression, and stiffness can receive different factors. Moisture also causes shrinkage and swelling primarily across grain, affecting bearing, connections, and differential movement.

For glulam, verify the bending axis, tension side, combination symbol, and whether a beam can be inverted; laminations may be arranged for a specified stress pattern. For laminated veneer lumber or other structural composite lumber, use product-specific reference values and orientation. For wood structural panels, align the marked strength axis with the assumed span and diaphragm direction. A correctly graded product installed about the wrong axis can fail the analytical assumption without any material defect.

Finish with four questions: Did I select the correct product table and grade? Did I use actual dimensions and axes? Did I apply each factor only to an eligible property? Did I compare ASD demand with ASD capacity? If any answer is uncertain, an attractive numerical ratio is not yet a valid wood design.