Study guide
12.2 Stormwater Collection Systems and Inlet Capacities
PE Civil: Transportation Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Project Management
1.1 Quantity and Cost Estimating 1.2 Project Scheduling and CPM 1.3 Engineering Economic Analysis
2 Chapter 2: Traffic Engineering - Capacity and Flow
2.1 Uninterrupted Flow Capacity and Level of Service (LOS) 2.2 Interrupted Flow on Segment Streets 2.3 Intersection Capacity and LOS 2.4 Nonmotorized Facilities Analysis
3 Chapter 3: Traffic Engineering - Studies and Safety
3.1 Traffic Volume, Speed, and Planning Studies 3.2 Traffic Forecasts and Monitoring 3.3 Traffic Safety and Collision Analysis 3.4 Highway Safety and Crash Modification Factors (CMFs)
4 Chapter 4: Roadside and Cross-Section Design
4.1 Forgiving Roadside and Clear Zone Design 4.2 Barrier Design and Length of Need 4.3 Cross-Section Design Elements 4.4 Nonmotorized Design Considerations
5 Chapter 5: Horizontal Alignment Design
5.1 Circular Curve Elements and Calculations 5.2 Design Speed and Superelevation Design 5.3 Horizontal Sight Distance and Obstructions
6 Chapter 6: Vertical Alignment Design
6.1 Grades, Slopes, and Profile Design 6.2 Crest Vertical Curve Geometry and Sight Distance 6.3 Sag Vertical Curve Geometry and Sight Distance 6.4 Vertical Clearance Under Structures
7 Chapter 7: Intersection Geometry and Layout
7.1 At-Grade Intersection Design and Roundabouts 7.2 Intersection Sight Distance and Sight Triangles 7.3 Interchange Ramps and Terminal Geometry
8 Chapter 8: Traffic Signals
8.1 Traffic Signal Timing and Phasing 8.2 Traffic Signal Warrants (MUTCD) 8.3 Traffic Signal Design and Preemption
9 Chapter 9: Traffic Control Design
9.1 Permanent Signing Design and Standards 9.2 Pavement Marking Layout and Rules 9.3 Temporary Traffic Control and Work Zones
10 Chapter 10: Geotechnical and Pavements
10.1 Sampling, Testing, and Soil Stabilization 10.2 Fundamental Soil Properties and Mass Balance 10.3 Compaction, Excavation, and Mass Diagrams 10.4 Flexible and Rigid Pavement Design and ESALs
11 Chapter 11: Hydrology and Open-Channel Drainage
11.1 Rainfall Hydrology and Rational Method 11.2 Open-Channel Flow and Manning's Equation 11.3 Peak Flow Mitigation and Water-Quality
12 Chapter 12: Drainage Structures and Systems
12.1 Culvert Design and Inlet/Outlet Control 12.2 Stormwater Collection Systems and Inlet Capacities
12.2 Stormwater Collection Systems and Inlet Capacities
Key Takeaways Explain This Topic AI
Modified Manning's equation for triangular gutter flow is Q = 0.56 n S x 1.67 S L 0.5 T 2.67 Q = \frac{0.56}{n} S_x^{1.67} S_L^{0.5} T^{2.67} Q = n 0.56 S x 1.67 S L 0.5 T 2.67 , indicating that gutter spread ( T T T ) varies directly with the 3 / 8 3/8 3/8 power of flow rate.
Grate inlets in a sump (sag) operate as weirs at shallow water depths ( d ≤ 0.4 ft d \le 0.4\text{ ft} d ≤ 0.4 ft ) with Q i = C w P d 1.5 Q_i = C_w P d^{1.5} Q i = C w P d 1.5 , and transition to orifices at depths d ≥ 1.4 ft d \ge 1.4\text{ ft} d ≥ 1.4 ft with Q i = C o A g 2 g d Q_i = C_o A_g \sqrt{2gd} Q i = C o A g 2 g d .
For curb inlets on grade, the total length required for 100% flow interception ( L T L_T L T ) is a function of flow rate, longitudinal slope, and cross slope; if L < L T L < L_T L < L T , efficiency is E = 1 − ( 1 − L / L T ) 1.8 E = 1 - (1 - L/L_T)^{1.8} E = 1 − ( 1 − L / L T ) 1.8 .
Storm sewer pipe designs must maintain a self-cleansing velocity of at least 2.0 ft/s 2.0\text{ ft/s} 2.0 ft/s under full flow conditions to prevent sediment deposition, while limiting maximum velocity to 15.0 ft/s 15.0\text{ ft/s} 15.0 ft/s to prevent pipe erosion.
The Hydraulic Grade Line (HGL) represents the pressure plus potential head, while the Energy Grade Line (EGL) includes velocity head ( V 2 / 2 g V^2/2g V 2 /2 g ); at junctions, HGL must account for local minor losses ( K V o 2 / 2 g K V_o^2 / 2g K V o 2 /2 g ).
Last updated: July 2026
- Stormwater Collection Systems and Inlet Capacities
- Pavement Drainage and Stormwater Collection
Stormwater collection systems are critical for highway safety. Standing water on pavement (spread) can cause hydroplaning, reduce visibility due to spray, and compromise structural integrity of the subgrade. Design guidelines, such as FHWA HEC-22 (Circular 22), establish limits on the allowable spread ( T T T ) of stormwater onto the shoulder or travel lanes during a design storm (typically a 10-year or 5-year event).
Gutter Flow and Spread Calculations
Gutter flow is considered open-channel flow in a shallow, triangular channel formed by the pavement cross slope and the curb. Because the hydraulic radius of a shallow triangular flow section is not representative of typical open channels, Manning's equation is modified (Manning's modified formula or Izzard's equation) to calculate the gutter flow capacity: Q = 0.56 n S x 1.67 S L 0.5 T 2.67 Q = \frac{0.56}{n} S_x^{1.67} S_L^{0.5} T^{2.67} Q = n 0.56 S x 1.67 S L 0.5 T 2.67
Where:
Q Q Q = Gutter flow rate (cfs)
n n n = Manning's roughness coefficient (typically 0.015 0.015 0.015 to 0.016 0.016 0.016 for smooth concrete pavement)
- S x S_x S x = Pavement cross slope (ft/ft)
- S L S_L S L = Longitudinal slope of the roadway (ft/ft)
- T T T = Width of flow or pavement spread (ft)
Solving for the pavement spread ( T T T ) for a given design runoff Q Q Q : T = ( Q ⋅ n 0.56 ⋅ S x 1.67 ⋅ S L 0.5 ) 0.375 T = \left( \frac{Q \cdot n}{0.56 \cdot S_x^{1.67} \cdot S_L^{0.5}} \right)^{0.375} T = ( 0.56 ⋅ S x 1.67 ⋅ S L 0.5 Q ⋅ n ) 0.375
If the cross-section has a depressed gutter (where the cross slope near the curb is steeper than the pavement cross slope), the flow is divided into the gutter section and the pavement section. The total flow is Q = Q w + Q s Q = Q_w + Q_s Q = Q w + Q s , where Q w Q_w Q w is the flow in the depressed gutter width ( W W W ) and Q s Q_s Q s is the flow on the remaining pavement spread.
Inlet Types and Hydraulics
Inlets are placed at low points (sumps/sags) and on continuous grades to intercept gutter flow and convey it into the underground storm sewer system. The capacity of an inlet depends on its type, location, and geometry.
Inlets on Continuous Grade
On a continuous grade, inlets rarely intercept 100% of the gutter flow. The performance is defined by its interception efficiency ( E E E ): E = Q i Q E = \frac{Q_i}{Q} E = Q Q i
Where Q i Q_i Q i is the intercepted flow (cfs) and Q Q Q is the total gutter flow (cfs). The remaining flow that bypasses the inlet is the bypass or carryover flow ( Q b = Q − Q i Q_b = Q - Q_i Q b = Q − Q i ).
Grate Inlets on Grade: Grate capacity depends on the portion of flow passing directly over the grate (frontal flow) and the flow passing along the side (side flow).
Frontal Flow Ratio ( E o E_o E o ): The ratio of frontal flow ( Q w Q_w Q w ) to total gutter flow ( Q Q Q ): E o = Q w Q = 1 − ( 1 − W T ) 2.67 E_o = \frac{Q_w}{Q} = 1 - \left( 1 - \frac{W}{T} \right)^{2.67} E o = Q Q w = 1 − ( 1 − T W ) 2.67 Where W W W is the grate width (ft) and T T T is the spread (ft).
Interception Efficiency ( E E E ): E = R f E o + R s ( 1 − E o ) E = R_f E_o + R_s (1 - E_o) E = R f E o + R s ( 1 − E o ) Where R f R_f R f is the frontal flow interception efficiency (drops from 1.0 to less if velocity exceeds the splash-over velocity) and R s R_s R s is the side flow interception efficiency (typically 0.1 0.1 0.1 to 0.2 0.2 0.2 ).
Curb Inlets on Grade: Curb inlets are highly effective at intercepting flow and are less prone to clogging. The length of curb opening required for 100% interception ( L T L_T L T ) is given by: L T = 0.6 Q 0.42 S L 0.3 ( 1 n S x ) 0.6 L_T = 0.6 Q^{0.42} S_L^{0.3} \left( \frac{1}{n S_x} \right)^{0.6} L T = 0.6 Q 0.42 S L 0.3 ( n S x 1 ) 0.6 If the actual length of the curb inlet ( L L L ) is less than L T L_T L T , its efficiency is calculated as: E = 1 − ( 1 − L L T ) 1.8 E = 1 - \left( 1 - \frac{L}{L_T} \right)^{1.8} E = 1 − ( 1 − L T L ) 1.8
Combination Inlets on Grade: Consist of a curb opening and a grate. On grade, their capacity is generally assumed to be equal to the grate alone if the grate is placed adjacent to the curb opening. However, placing the curb opening upstream of the grate increases total capacity and reduces clogging.
Inlets in a Sump (Sag)
In a sump or sag, water pools around the inlet. The inlet operates under two distinct hydraulic regimes depending on the depth of ponding ( d d d ):
Grate Inlets in Sump:
Weir Flow (Shallow Depths, d ≤ 0.4 ft d \le 0.4\text{ ft} d ≤ 0.4 ft ): Capacity is limited by the perimeter of the grate ( P P P , excluding the side against the curb): Q i = C w P d 1.5 = 3.0 P d 1.5 Q_i = C_w P d^{1.5} = 3.0 P d^{1.5} Q i = C w P d 1.5 = 3.0 P d 1.5
Orifice Flow (Deep Depths, d ≥ 1.4 ft d \ge 1.4\text{ ft} d ≥ 1.4 ft ): Capacity is limited by the clear opening area ( A g A_g A g ): Q i = C o A g 2 g d = 0.67 A g 2 g d Q_i = C_o A_g \sqrt{2 g d} = 0.67 A_g \sqrt{2 g d} Q i = C o A g 2 g d = 0.67 A g 2 g d
Transition ( 0.4 ft < d < 1.4 ft 0.4\text{ ft} < d < 1.4\text{ ft} 0.4 ft < d < 1.4 ft ): Flow is transitional, and the lesser of the weir and orifice capacities is typically used.
Curb Inlets in Sump:
Weir Flow ( d ≤ h d \le h d ≤ h , where h h h is curb opening height): Q i = C w L d 1.5 = 3.0 L d 1.5 Q_i = C_w L d^{1.5} = 3.0 L d^{1.5} Q i = C w L d 1.5 = 3.0 L d 1.5 (Or 2.3 L d 1.5 2.3 L d^{1.5} 2.3 L d 1.5 for undepressed curb inlets).
Orifice Flow ( d ≥ 1.4 h d \ge 1.4 h d ≥ 1.4 h ): Q i = C o A i 2 g ( d − h 2 ) = 0.67 L h 2 g ( d − h 2 ) Q_i = C_o A_i \sqrt{2 g \left( d - \frac{h}{2} \right)} = 0.67 L h \sqrt{2 g \left( d - \frac{h}{2} \right)} Q i = C o A i 2 g ( d − 2 h ) = 0.67 L h 2 g ( d − 2 h )
Storm Sewer Pipe Design and Velocities
Once intercepted, stormwater flows through a network of pipes (laterals and trunks) and manholes/junctions to an outfall.
Design Flow ( Q Q Q ): Pipe diameters are sized using the Rational Method ( Q = C I A Q = C I A Q = C I A ) where the time of concentration ( t c t_c t c ) is computed for the critical pathway.
Capacity Sizing: Manning's equation is used to size the pipe to flow gravity full under gravity flow conditions: Q = 1.486 n A R 2 / 3 S 0 0.5 Q = \frac{1.486}{n} A R^{2/3} S_0^{0.5} Q = n 1.486 A R 2/3 S 0 0.5
Velocity Criteria:
Minimum Velocity (Self-Cleansing): Pipes must be designed to maintain a full-flow velocity of at least 2.0 fps 2.0\text{ fps} 2.0 fps to prevent the deposition of sand, grit, and silt.
Maximum Velocity: Velocities must not exceed 15.0 fps 15.0\text{ fps} 15.0 fps to prevent concrete pipe scour and joints from separating due to high shear forces.
Hydraulic and Energy Grade Lines
Calculations of the Hydraulic Grade Line (HGL) and Energy Grade Line (EGL) are performed starting from the downstream outfall and working upstream.
Energy Grade Line (EGL): Represents the total energy head of the water: E G L = Elevation + Depth + V 2 2 g EGL = \text{Elevation} + \text{Depth} + \frac{V^2}{2g} EG L = Elevation + Depth + 2 g V 2
Hydraulic Grade Line (HGL): Represents the potential and pressure head: H G L = Elevation + Depth = E G L − V 2 2 g HGL = \text{Elevation} + \text{Depth} = EGL - \frac{V^2}{2g} H G L = Elevation + Depth = EG L − 2 g V 2 If the pipe is flowing under pressure (surcharged), the depth term represents the pressure head ( P / γ P/\gamma P / γ ) above the pipe soffit (top of pipe).
Junction and Manhole Head Losses: Minor losses occur at bends, expansions, contractions, and junction manholes. The loss ( H j H_j H j ) is calculated as: H j = K V o 2 2 g H_j = K \frac{V_o^2}{2g} H j = K 2 g V o 2 Where K K K is the junction loss coefficient (typically 0.2 0.2 0.2 to 0.9 0.9 0.9 depending on flow deflection angle and pipe diameter ratios) and V o V_o V o is the velocity in the outlet pipe.
Starting HGL: The backwater analysis begins at the outfall. If the outfall discharges into a body of water with a known water surface elevation (tailwater), the HGL starts at that tailwater elevation. If the tailwater is below the critical depth of the pipe, the starting HGL is max ( T W , ( d c + D ) / 2 ) \max(TW, (d_c + D)/2) max ( T W , ( d c + D ) /2 ) .