Study guide
11.2 Open-Channel Flow and Manning's Equation
PE Civil: Transportation Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Project Management
1.1 Quantity and Cost Estimating 1.2 Project Scheduling and CPM 1.3 Engineering Economic Analysis
2 Chapter 2: Traffic Engineering - Capacity and Flow
2.1 Uninterrupted Flow Capacity and Level of Service (LOS) 2.2 Interrupted Flow on Segment Streets 2.3 Intersection Capacity and LOS 2.4 Nonmotorized Facilities Analysis
3 Chapter 3: Traffic Engineering - Studies and Safety
3.1 Traffic Volume, Speed, and Planning Studies 3.2 Traffic Forecasts and Monitoring 3.3 Traffic Safety and Collision Analysis 3.4 Highway Safety and Crash Modification Factors (CMFs)
4 Chapter 4: Roadside and Cross-Section Design
4.1 Forgiving Roadside and Clear Zone Design 4.2 Barrier Design and Length of Need 4.3 Cross-Section Design Elements 4.4 Nonmotorized Design Considerations
5 Chapter 5: Horizontal Alignment Design
5.1 Circular Curve Elements and Calculations 5.2 Design Speed and Superelevation Design 5.3 Horizontal Sight Distance and Obstructions
6 Chapter 6: Vertical Alignment Design
6.1 Grades, Slopes, and Profile Design 6.2 Crest Vertical Curve Geometry and Sight Distance 6.3 Sag Vertical Curve Geometry and Sight Distance 6.4 Vertical Clearance Under Structures
7 Chapter 7: Intersection Geometry and Layout
7.1 At-Grade Intersection Design and Roundabouts 7.2 Intersection Sight Distance and Sight Triangles 7.3 Interchange Ramps and Terminal Geometry
8 Chapter 8: Traffic Signals
8.1 Traffic Signal Timing and Phasing 8.2 Traffic Signal Warrants (MUTCD) 8.3 Traffic Signal Design and Preemption
9 Chapter 9: Traffic Control Design
9.1 Permanent Signing Design and Standards 9.2 Pavement Marking Layout and Rules 9.3 Temporary Traffic Control and Work Zones
10 Chapter 10: Geotechnical and Pavements
10.1 Sampling, Testing, and Soil Stabilization 10.2 Fundamental Soil Properties and Mass Balance 10.3 Compaction, Excavation, and Mass Diagrams 10.4 Flexible and Rigid Pavement Design and ESALs
11 Chapter 11: Hydrology and Open-Channel Drainage
11.1 Rainfall Hydrology and Rational Method 11.2 Open-Channel Flow and Manning's Equation 11.3 Peak Flow Mitigation and Water-Quality
12 Chapter 12: Drainage Structures and Systems
12.1 Culvert Design and Inlet/Outlet Control 12.2 Stormwater Collection Systems and Inlet Capacities
11.2 Open-Channel Flow and Manning's Equation
Key Takeaways Explain This Topic AI
Manning's equation is a semi-empirical formula for uniform open-channel flow: Q = (1.486 / n) * A * R^(2/3) * S^(1/2) in US Customary, and Q = (1.0 / n) * A * R^(2/3) * S^(1/2) in SI.
The hydraulic radius (R) is defined as the cross-sectional area of flow (A) divided by the wetted perimeter (P): R = A / P.
Froude Number (Fr = V / sqrt(g * D)) determines flow regime: subcritical flow (Fr < 1), critical flow (Fr = 1), and supercritical flow (Fr > 1).
Critical depth (yc) represents the flow depth at which the specific energy is minimized for a given discharge. For rectangular channels, yc = (q^2 / g)^(1/3).
Permissible shear stress design ensures the maximum boundary shear stress (tau_d = gamma * y * S on channel bed) does not exceed the allowable shear stress (tau_p) of the lining material.
Last updated: July 2026
- 11.2 Open-Channel Flow and Manning's Equation
- Fundamentals of Open-Channel Flow
Open-channel flow occurs when liquid flows in a conduit with a free surface exposed to atmospheric pressure. Unlike pressure flow in pipes, open-channel flow is driven solely by gravity and the slope of the channel bed. In highway design, open channels include roadside ditches, gutters, median swales, culverts flowing under gravity, and natural streams.
To analyze open-channel hydraulics, we define several geometric parameters based on the cross-sectional shape of the water flow:
Flow Depth ( y y y ): The vertical distance from the lowest point of the channel bed to the water surface.
Cross-Sectional Area ( A A A ): The area of flow perpendicular to the direction of velocity.
Wetted Perimeter ( P P P ): The length of the channel boundary in contact with the water.
Hydraulic Radius ( R R R ): The ratio of flow area to wetted perimeter ( R = A / P R = A/P R = A / P ). It represents the relative efficiency of the channel cross-section.
Top Width ( T T T ): The width of the channel at the free water surface.
Hydraulic Depth ( D D D ): The ratio of flow area to top width ( D = A / T D = A/T D = A / T ).
Summary of Geometric Equations
The table below summarizes the geometric relations for common channel shapes:
- Shape Area ( A A A ) Wetted Perimeter ( P P P ) Top Width ( T T T ) Hydraulic Radius ( R R R )
- Rectangular b ⋅ y b \cdot y b ⋅ y b + 2 y b + 2y b + 2 y b b b b y b + 2 y \frac{b y}{b + 2y} b + 2 y b y
Trapezoidal ( b + z y ) y (b + z y)y ( b + zy ) y b + 2 y 1 + z 2 b + 2y\sqrt{1 + z^2} b + 2 y 1 + z 2 b + 2 z y b + 2 z y b + 2 zy ( b + z y ) y b + 2 y 1 + z 2 \frac{(b + z y)y}{b + 2y\sqrt{1 + z^2}} b + 2 y 1 + z 2 ( b + zy ) y
Triangular z ⋅ y 2 z \cdot y^2 z ⋅ y 2 2 y 1 + z 2 2y\sqrt{1 + z^2} 2 y 1 + z 2 2 z y 2 z y 2 zy z y 2 1 + z 2 \frac{z y}{2\sqrt{1 + z^2}} 2 1 + z 2 zy
Circular (Half Full) π d 2 8 \frac{\pi d^2}{8} 8 π d 2 π d 2 \frac{\pi d}{2} 2 π d d d d d 4 \frac{d}{4} 4 d
(where b b b is bottom width, z z z is side slope horizontal-to-vertical ratio z z z :1, and d d d is diameter).
Manning's Equation for Uniform Flow
Under uniform flow conditions, the water depth, cross-sectional area, velocity, and discharge remain constant along the channel. In this state, the gravitational driving force is exactly balanced by the frictional resistance of the channel boundaries. Uniform flow is analyzed using Manning's Equation:
US Customary Units Q = 1.486 n ⋅ A ⋅ R 2 / 3 ⋅ S 1 / 2 Q = \frac{1.486}{n} \cdot A \cdot R^{2/3} \cdot S^{1/2} Q = n 1.486 ⋅ A ⋅ R 2/3 ⋅ S 1/2 V = 1.486 n ⋅ R 2 / 3 ⋅ S 1 / 2 V = \frac{1.486}{n} \cdot R^{2/3} \cdot S^{1/2} V = n 1.486 ⋅ R 2/3 ⋅ S 1/2
SI Units Q = 1.0 n ⋅ A ⋅ R 2 / 3 ⋅ S 1 / 2 Q = \frac{1.0}{n} \cdot A \cdot R^{2/3} \cdot S^{1/2} Q = n 1.0 ⋅ A ⋅ R 2/3 ⋅ S 1/2 V = 1.0 n ⋅ R 2 / 3 ⋅ S 1 / 2 V = \frac{1.0}{n} \cdot R^{2/3} \cdot S^{1/2} V = n 1.0 ⋅ R 2/3 ⋅ S 1/2
Where:
- Q Q Q = Flow rate or discharge (cfs or m 3 / s m^3/s m 3 / s )
- V V V = Mean flow velocity (fps or m/s)
- n n n = Manning's roughness coefficient (dimensionless, representing boundary friction)
- A A A = Cross-sectional area of flow ( f t 2 ft^2 f t 2 or m 2 m^2 m 2 )
- R R R = Hydraulic radius (ft or m)
- S S S = Channel slope (ft/ft or m/m)
- Manning's Roughness Coefficient ( n n n )
Manning's n n n varies significantly based on the channel material and vegetation:
- Channel Material Typical Manning's n n n
- Smooth Concrete 0.011 - 0.013
- Corrugated Metal Pipe (CMP) 0.024 - 0.027
- Clean Earth / Excavated 0.018 - 0.025
- Grass-Lined Swale (Shallow) 0.030 - 0.050
- Gravel / Riprap 0.035 - 0.070
- Natural Stream (Weeds/Debris) 0.050 - 0.100
- Specific Energy and Critical Flow
Specific energy ( E E E ) is the energy of flow at a given cross-section relative to the channel bed: E = y + V 2 2 g = y + Q 2 2 g A 2 E = y + \frac{V^2}{2g} = y + \frac{Q^2}{2g A^2} E = y + 2 g V 2 = y + 2 g A 2 Q 2
For a constant discharge Q Q Q , the specific energy curve exhibits a minimum value at a unique depth called the critical depth ( y c y_c y c ) .
The Froude Number
The Froude number ( F r Fr F r ) is a dimensionless parameter representing the ratio of inertial forces to gravitational forces: F r = V g D Fr = \frac{V}{\sqrt{g D}} F r = g D V
where g g g is the acceleration of gravity ( 32.2 ft/s 2 32.2 \text{ ft/s}^2 32.2 ft/s 2 or 9.81 m/s 2 9.81 \text{ m/s}^2 9.81 m/s 2 ) and D D D is the hydraulic depth ( A / T A/T A / T ).
The Froude number determines the flow regime:
Subcritical Flow ( F r < 1 Fr < 1 F r < 1 ): Water depth is greater than critical depth ( y > y c y > y_c y > y c ). Flow is slow, tranquil, and controlled by downstream conditions.
Critical Flow ( F r = 1 Fr = 1 F r = 1 ): Flow is at minimum specific energy ( y = y c y = y_c y = y c ).
Supercritical Flow ( F r > 1 Fr > 1 F r > 1 ): Water depth is less than critical depth ( y < y c y < y_c y < y c ). Flow is fast, rapid, and controlled by upstream conditions. A transition from supercritical to subcritical flow results in a hydraulic jump, which dissipates energy but can cause severe erosion.
Critical Depth in Rectangular Channels
For a rectangular channel, the critical depth ( y c y_c y c ) is solved directly as: y c = ( q 2 g ) 1 / 3 y_c = \left(\frac{q^2}{g}\right)^{1/3} y c = ( g q 2 ) 1/3
where q = Q / b q = Q/b q = Q / b is the unit discharge (discharge per unit width of the channel, cfs/ft).
Channel Lining and Shear Stress Design (HEC-15)
Roadside ditches must be designed to withstand erosion caused by flowing water. The Federal Highway Administration (FHWA) publication HEC-15 governs the design of flexible channel linings (e.g., grass, gravel, riprap) using tractive force theory.
The average shear stress ( τ \tau τ ) exerted by flowing water on the channel boundary is: τ = γ ⋅ R ⋅ S \tau = \gamma \cdot R \cdot S τ = γ ⋅ R ⋅ S
For wide channels ( b / y > 10 b/y > 10 b / y > 10 ), the hydraulic radius R R R approaches the flow depth y y y , simplifying the maximum boundary shear stress on the channel bed to: τ d = γ ⋅ y ⋅ S \tau_d = \gamma \cdot y \cdot S τ d = γ ⋅ y ⋅ S
Where:
τ d \tau_d τ d = Design shear stress ( lb/ft 2 \text{lb/ft}^2 lb/ft 2 or Pa)
γ \gamma γ = Unit weight of water ( 62.4 lb/ft 3 62.4 \text{ lb/ft}^3 62.4 lb/ft 3 or 9810 N/m 3 9810 \text{ N/m}^3 9810 N/m 3 )
- y y y = Maximum flow depth (ft or m)
- S S S = Channel slope (ft/ft or m/m)
Design Rule: To prevent erosion, the design shear stress ( τ d \tau_d τ d ) must not exceed the permissible shear stress ( τ p \tau_p τ p ) of the lining material: τ d ≤ τ p \tau_d \le \tau_p τ d ≤ τ p
If τ d > τ p \tau_d > \tau_p τ d > τ p , a more robust lining (such as larger riprap or concrete paving) must be selected.