Study guide
4.4 Nonmotorized Design Considerations
PE Civil: Transportation Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Project Management
1.1 Quantity and Cost Estimating 1.2 Project Scheduling and CPM 1.3 Engineering Economic Analysis
2 Chapter 2: Traffic Engineering - Capacity and Flow
2.1 Uninterrupted Flow Capacity and Level of Service (LOS) 2.2 Interrupted Flow on Segment Streets 2.3 Intersection Capacity and LOS 2.4 Nonmotorized Facilities Analysis
3 Chapter 3: Traffic Engineering - Studies and Safety
3.1 Traffic Volume, Speed, and Planning Studies 3.2 Traffic Forecasts and Monitoring 3.3 Traffic Safety and Collision Analysis 3.4 Highway Safety and Crash Modification Factors (CMFs)
4 Chapter 4: Roadside and Cross-Section Design
4.1 Forgiving Roadside and Clear Zone Design 4.2 Barrier Design and Length of Need 4.3 Cross-Section Design Elements 4.4 Nonmotorized Design Considerations
5 Chapter 5: Horizontal Alignment Design
5.1 Circular Curve Elements and Calculations 5.2 Design Speed and Superelevation Design 5.3 Horizontal Sight Distance and Obstructions
6 Chapter 6: Vertical Alignment Design
6.1 Grades, Slopes, and Profile Design 6.2 Crest Vertical Curve Geometry and Sight Distance 6.3 Sag Vertical Curve Geometry and Sight Distance 6.4 Vertical Clearance Under Structures
7 Chapter 7: Intersection Geometry and Layout
7.1 At-Grade Intersection Design and Roundabouts 7.2 Intersection Sight Distance and Sight Triangles 7.3 Interchange Ramps and Terminal Geometry
8 Chapter 8: Traffic Signals
8.1 Traffic Signal Timing and Phasing 8.2 Traffic Signal Warrants (MUTCD) 8.3 Traffic Signal Design and Preemption
9 Chapter 9: Traffic Control Design
9.1 Permanent Signing Design and Standards 9.2 Pavement Marking Layout and Rules 9.3 Temporary Traffic Control and Work Zones
10 Chapter 10: Geotechnical and Pavements
10.1 Sampling, Testing, and Soil Stabilization 10.2 Fundamental Soil Properties and Mass Balance 10.3 Compaction, Excavation, and Mass Diagrams 10.4 Flexible and Rigid Pavement Design and ESALs
11 Chapter 11: Hydrology and Open-Channel Drainage
11.1 Rainfall Hydrology and Rational Method 11.2 Open-Channel Flow and Manning's Equation 11.3 Peak Flow Mitigation and Water-Quality
12 Chapter 12: Drainage Structures and Systems
12.1 Culvert Design and Inlet/Outlet Control 12.2 Stormwater Collection Systems and Inlet Capacities
4.4 Nonmotorized Design Considerations
Key Takeaways Explain This Topic AI
The maximum running slope of an ADA-compliant ramp is 8.33% (1:12), and the maximum cross slope is 2.0% (1:50).
Pedestrian refuge islands must have a minimum width of 6.0 feet in the direction of travel to safely shelter a pedestrian or wheelchair.
ADA curb ramps require a minimum 4.0 x 4.0 foot flat landing at the top of perpendicular ramps to allow wheelchair turning.
Shared-use paths should be a minimum of 10 feet wide (two-way) and maintain a cross slope of 1.5% to 2.0% for drainage and accessibility.
Truncated dome detectable warnings must be 24 inches deep in the direction of travel and span the full width of the ramp exit.
Last updated: July 2026
Nonmotorized Design Considerations
Designing for nonmotorized users—pedestrians, bicyclists, and users of personal mobility devices—requires a distinct set of geometric standards focused on safety, accessibility, and comfort. Unlike motor vehicle design, which prioritizes speed and volume, nonmotorized design prioritizes physical vulnerability and human scale. This section details key design elements, including ADA compliance, curb ramp geometry, pedestrian refuge islands, and bicycle path geometry.
ADA Accessibility Requirements for Pedestrian Routes
The Americans with Disabilities Act (ADA) requires all public pedestrian facilities to be fully accessible. This is achieved by designing a continuous Pedestrian Access Route (PAR) . The PAR is the designated walk path that connects buildings, transit stops, parking, and public spaces. It must be free of steps, sudden changes in level greater than 0.25 inches, or vertical obstructions.
Running Slope and Cross Slope
Running Slope (Grade) : The sidewalk longitudinal grade should match the adjacent roadway. However, for independent ramps, the maximum running slope is 8.33% (1:12) . Slopes steeper than 5.0% (1:20) are classified as ramps and require handrails and landings.
Cross Slope : The cross slope of a PAR must not exceed 2.0% (1:50) . At intersections, the crosswalk cross slope must stay within 2.0% (except at unsignalized intersections, where it may match the roadway grade).
Sidewalk Clearances and Vertical Clearances
Width : The minimum clear width for a sidewalk is 5.0 feet (60 inches) . If a sidewalk width is reduced to 4.0 feet due to an obstruction (such as a utility pole or fire hydrant), passing spaces of at least 5.0 feet by 5.0 feet must be provided at intervals of no more than 200 feet. This ensures that two manual wheelchair users can easily pass each other without stepping off the paved surface.
Vertical Clearance : A vertical clearance of at least 80 inches (6.67 feet) is required to prevent head injuries from overhead obstructions.
ADA Curb Ramp Geometry
Curb ramps provide a smooth transition between the sidewalk and the street. There are two primary types of curb ramps: perpendicular (which run straight down to the street) and parallel (which lower the sidewalk level parallel to the curb).
Design Standards for Perpendicular Ramps
Ramp Slope : The maximum running slope of the ramp is 8.33% (1:12) .
Flare Slopes : If pedestrians can walk across the sides of the ramp, the flares must have a maximum slope of 10.0% (1:10) . If the sides are protected by grass or physical barriers, flares are not required.
Top Landing : Perpendicular ramps require a flat landing of at least 4.0 feet by 4.0 feet at the top. This allows wheelchair users to turn or pass through without rolling down the ramp.
Bottom Transition : The ramp-to-gutter transition must be flush. The gutter slope leading to the ramp must not exceed 5.0% .
Detectable Warnings (Truncated Domes)
To alert visually impaired pedestrians, curb ramps must feature detectable warning surfaces consisting of raised, truncated domes.
Dimensions : The dome pattern must extend 24 inches in the direction of pedestrian travel and span the full width of the ramp.
Contrast : The surface must contrast visually (light-on-dark or dark-on-light) with the surrounding pavement.
Pedestrian Refuge Islands
At wide intersections, a pedestrian refuge island provides a safe mid-crossing waiting area.
Minimum Width : The refuge island must be at least 6.0 feet wide in the direction of travel to accommodate a stroller, a bicycle, or a wheelchair.
Detectable Warnings : Cut-throughs must have truncated domes at both sides of the island where pedestrians enter the street, with a minimum 2.0-foot-wide flat walkway in between.
Bicycle Path Geometry (Shared-Use Paths)
Shared-use paths are physically separated from motorized traffic and are designed for two-way travel by bicyclists, pedestrians, and skaters.
Width and Clearance
Width : The standard width for a two-way path is 10 feet (12 to 14 feet in high-volume areas). A width of 8 feet is allowed only in highly constrained, low-volume settings.
Horizontal Clearance : A minimum 2.0-foot-wide graded shoulder (clear zone) with a maximum slope of 1V:6H must be provided on both sides of the path.
Horizontal Alignment (Curve Radii)
Bicycle curves must reflect operating speeds. The minimum radius ( R R R ) for a horizontal curve on a bike path is: R = V 2 15 ( e + f ) R = \frac{V^2}{15(e + f)} R = 15 ( e + f ) V 2
where V V V is the design speed (mph), e e e is the superelevation rate (usually 2.0% or 0.02 for a flat path with drainage cross slope), and f f f is the side friction factor (typically 0.25 to 0.30 for bicycles). For a design speed of 18 mph and a standard 2% cross slope, the minimum radius is approximately 60 feet . If a path is paved with asphalt, the friction coefficient is high, but if the path is unpaved (crushed stone or soil), the side friction factor ( f f f ) must be reduced to 0.15, which significantly increases the minimum required radius to prevent skidding.
Shared-Use Path Grades and Accessibility
Since shared-use paths serve pedestrians and wheelchair users, they must comply with ADA guidelines.
Maximum Grade : The longitudinal grade must not exceed 5.0% to remain accessible. If terrain dictates, grades up to 8.33% are permitted for runs under 30 feet, provided a flat 5.0 ft by 5.0 ft landing is provided at both ends.
Stopping Sight Distance : Stopping sight distance (SSD) is critical due to speed differentials. For a 15 mph bicycle speed, a baseline SSD of 80 feet is required, which must be increased on downgrades to account for longer braking distances.