Study guide
2.5 Fire Safety, Prevention, and Emergency Response
DOLE Basic Occupational Safety and Health BOSH
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: OSH Foundations & Philippines Legislation
1.1 Philippines OSH Situationer & DOLE Framework 1.2 Republic Act No. 11058 & DOLE Department Order No. 198-18 / DO 252-25 1.3 Occupational Safety and Health Standards (OSHS) Core Rules 1.4 Safety Officer Classifications, Roles, and Responsibilities (SO1 to SO4) 1.5 Employer and Worker Rights, Duties, and Non-Retaliation Protections
2 Chapter 2: Hazard Identification, Risk Assessment, and Control (HIRAC)
2.1 Principles of HIRAC & Risk Matrix Assessment 2.2 Unsafe Acts vs. Unsafe Conditions & Accident Etiology 2.3 Hierarchy of Controls (Elimination to PPE) 2.4 Workplace Housekeeping & 5S System Implementation 2.5 Fire Safety, Prevention, and Emergency Response 2.6 Electrical Safety and Machine Guarding 2.7 Personal Protective Equipment (PPE) Selection and Management
3 Chapter 3: Health Hazards & Industrial Hygiene
3.1 Physical Hazards 3.2 Chemical Hazards, SDS 16 Sections, and GHS Labeling 3.3 Biological Hazards & Workplace Infection Control 3.4 Ergonomic Hazards & Musculoskeletal Disorder Prevention 3.5 Industrial Hygiene & Workplace Health Surveillance
4 Chapter 4: OSH Inspection, Job Safety Analysis, & Incident Investigation
4.1 Workplace Safety Inspections & Checklist Development 4.2 Job Safety Analysis (JSA) Methodology 4.3 Incident/Accident Investigation & Root Cause Analysis 4.4 Accident Costing & Loss Prevention Concepts
5 Chapter 5: OSH Program Administration & Mandatory DOLE Reporting
5.1 Development and Integration of Workplace OSH Programs 5.2 OSH Committee Composition, Roles, and Meetings 5.3 Mandatory DOLE Reportorial Requirements (WAIR, AEDR, AMR) 5.4 Safety Officer 2 Re-entry Plan & Continuous OSH Improvement
2.5 Fire Safety, Prevention, and Emergency Response
Key Takeaways Explain This Topic AI
Fire requires four elements defined in the Fire Tetrahedron: Fuel, Oxygen, Heat, and an Uninhibited Chemical Chain Reaction.
Fires are classified under Philippine standards into Class A (ordinary combustibles), Class B (flammable liquids/gases), Class C (energized electrical), Class D (combustible metals), and Class K (cooking oils/fats).
Portable fire extinguishers are operated using the PASS acronym: Pull pin, Aim low at base of fire, Squeeze lever, Sweep side to side.
Water must NEVER be used on Class B flammable liquid fires (causes splattering) or Class C electrical fires (causes electrocution).
DOLE Rule 1940 and RA 9514 (Fire Code of the Philippines) mandate emergency response teams, unblocked exits, and annual evacuation drills.
Last updated: July 2026
- 2.5 Fire Safety, Prevention, and Emergency Response
- Chemistry of Fire: Triangle vs. Tetrahedron
To effectively prevent and extinguish fires, a Safety Officer 2 must understand the chemical mechanisms of combustion. Historically, fire was explained using the Fire Triangle , which consists of three elements:
Fuel: Any combustible material (solid, liquid, or gas).
Oxygen: Ambient air containing at least 16% oxygen concentration (normal air contains ~21% O 2 O_2 O 2 ).
Heat: Thermal energy sufficient to raise fuel to its ignition temperature.
Modern fire science expands this model into the Fire Tetrahedron , adding a crucial fourth element: the Uninhibited Chemical Chain Reaction . [ OXYGEN ]
- / \
- / \
- / FIRE \
- / TETRA \
- / HEDRON \
- [ FUEL ] ---+--------------+--- [ HEAT ]
- \
- \
- [ CHEMICAL CHAIN REACTION ]
Extinguishing Principle: Fire suppression works by removing one or more of the four sides of the tetrahedron:
Remove Heat -> Cooling (e.g., applying water).
Remove Oxygen -> Smothering (e.g., applying C O 2 CO_2 C O 2 or foam blanket).
Remove Fuel -> Starvation (e.g., shutting off fuel valves).
Interrupt Chain Reaction -> Chemical inhibition (e.g., applying Dry Chemical powders).
Fire Classifications & Extinguishing Agents
Under Philippine OSH Standards ( DOLE Rule 1940 ) and Republic Act No. 9514 ( Fire Code of the Philippines ), fires are categorized into five distinct classes based on fuel source:
1. Class A Fires (Ordinary Combustibles)
Fuel Source: Wood, paper, cloth, rubber, plastics, trash.
Extinguishing Agents: Water (cools), ABC Dry Chemical, Foam.
Identification Symbol: Green Triangle with letter 'A'.
2. Class B Fires (Flammable Liquids & Gases)
Fuel Source: Gasoline, diesel, kerosene, paint, oil-based solvents, methane, propane, LPG.
Extinguishing Agents: Carbon Dioxide ( C O 2 CO_2 C O 2 ), Foam (AFFF), ABC/BC Dry Chemical.
CRITICAL EXAM WARNING: NEVER use water on Class B fires! Water is heavier than most flammable liquids; liquid fuel will float on top of water, spreading flaming liquid rapidly across the facility.
Identification Symbol: Red Square with letter 'B'.
3. Class C Fires (Energized Electrical Equipment)
Fuel Source: Live electrical wiring, circuit breakers, electric motors, transformers, appliances.
Extinguishing Agents: Carbon Dioxide ( C O 2 CO_2 C O 2 ), BC/ABC Dry Chemical (non-conductive agents).
CRITICAL EXAM WARNING: NEVER use water or foam on live Class C fires! Water conducts electricity, causing immediate fatal electrocution to the operator. De-energizing the circuit reclassifies it to Class A or B.
Identification Symbol: Blue Circle with letter 'C'.
4. Class D Fires (Combustible Metals)
Fuel Source: Magnesium, titanium, sodium, potassium, zirconium, lithium.
Extinguishing Agents: Special Class D Dry Powder (e.g., sodium chloride or graphite-based agents).
CRITICAL EXAM WARNING: Water applied to burning magnesium causes a violent chemical reaction releasing hydrogen gas, resulting in severe explosions.
Identification Symbol: Yellow 5-Point Star with letter 'D'.
5. Class K Fires (Commercial Kitchen Oils & Greases)
Fuel Source: Vegetable oils, animal fats, lard, canola oil in deep fat fryers.
Extinguishing Agents: Wet Chemical agents (potassium acetate/potassium carbonate solutions).
Mechanism: Saponification—the wet chemical reacts with hot fat to form a thick soapy foam layer that smothers oxygen and cools oil below flash point.
Identification Symbol: Black Hexagon with letter 'K'.
- Portable Fire Extinguisher Operation & Placement
- The PASS Operating Method
When operating a portable fire extinguisher, personnel must follow the universal four-step PASS technique:
P - Pull: Pull the safety pin located at the top of the extinguisher handle, breaking the plastic tamper seal.
A - Aim: Aim the extinguisher nozzle or hose low, pointing directly at the base of the fire , not at the flames.
S - Squeeze: Squeeze operating handle or lever tightly to discharge extinguishing agent.
S - Sweep: Sweep nozzle side to side across the base of the fire until completely extinguished. [P]ull Pin ---> [A]im at Base ---> [S]queeze Lever ---> [S]weep Side-to-Side
DOLE Rule 1940 Extinguisher Placement Rules
Maximum Travel Distance to Extinguisher:
Class A hazard areas: Maximum 15 meters (50 feet) travel distance.
Class B hazard areas: Maximum 10 meters (30 feet) travel distance.
Mounting Height: Extinguishers weighing under 18 kg (40 lbs) must be mounted so top is no higher than 1.5 meters (5 feet) above floor. Extinguishers must never sit directly on floor.
Emergency Preparedness & Evacuation Planning
Under DOLE Rule 1940 and RA 9514 , the Safety Officer 2 is responsible for establishing an Emergency Preparedness and Response Program (EPRP) :
Fire Brigade Organization: Establish a trained workplace Fire Brigade headed by a Fire Safety Inspector / SO2.
Means of Egress (Exits):
Every building must have at least two unblocked, remote emergency exits per floor.
Exit doors must swing outward in direction of travel and be equipped with panic hardware.
Exits must never be locked, bolted, or obstructed during working hours.
Emergency Lighting & Signs: Illuminated "EXIT" signs backed by emergency battery units providing at least 90 minutes of illumination during power failure.
Drills & Exercises: Mandatory conducting of workplace fire drills and earthquake evacuation drills at least twice per year , with complete documentation submitted to DOLE and Bureau of Fire Protection (BFP).