Study guide
Search & Rescue Operations, PPE & SCBA Safety
Fire Officer Examination FOE
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Introduction & Exam Overview
About the Fire Officer Examination How to Use This Study Guide
2 Chapter 2: General Ability - Verbal Reasoning
Fire Service Vocabulary, Synonyms & Antonyms Verbal Analogies and Standard English Grammar Spelling, Correct Usage, Idioms & Punctuation Reading Comprehension and Passage Analysis
3 Chapter 3: General Ability - Analytical & Numerical Reasoning
Deductive Logic and Categorical Syllogisms Spatial Reasoning & Fireground Situational Judgment Data Interpretation: Tables, Graphs & Fire Incident Statistics Fundamental Arithmetic & Hydraulics Flow Rates Ratio, Proportion & Basic Algebra Percentages, Averages & Work/Time Word Problems Geometry, Mensuration & Measurement Conversions
4 Chapter 4: Fire Suppression - Science & Extinguishing Agents
Fire Behavior, Chemistry of Combustion & Fire Tetrahedron Classes of Fire and Extinguishing Media Portable Fire Extinguishers: Types, Ratings, PASS & Maintenance Firefighting Foam: Concentrates, Proportioning & Application Water Supply Systems, Pressure & Fire Hydraulics
5 Chapter 5: Fire Suppression - Operations & Equipment
Pre-Fire Planning, Size-Up & Incident Command System Fire Attack Tactics, Ventilation & Overhaul Salvage Operations, Loss Control & Property Conservation Hose Lines, Nozzles, Ground Ladders & Forcible Entry Fire Apparatus, Pump Operations & Apparatus Positioning Search & Rescue Operations, PPE & SCBA Safety BFP Emergency Medical Services & Special Rescue Operations Hazardous Materials Incident Response & Mitigation
6 Chapter 6: Fire Safety & Prevention - Philippine Fire Code (RA 9514)
Republic Act 9514 (Fire Code of the Philippines 2008) Scope & Principles 2019 Revised IRR Enforcement, Administrative Sanctions & Closure Orders Fire Safety Inspection Certificate (FSIC) & FSEC Requirements Fire Code Fees, Taxes & the Collection of Fire Code Revenues
7 Chapter 7: Fire Safety & Prevention - Codes & Inspection SOPs
Means of Egress Specifications & Fire Protection Systems Philippine Electrical Code & Electrical Fire Hazards Hazardous Materials Classification & High-Risk Occupancies Fire Drills, Evacuation Planning, Fire Brigades & Public Fire Safety Education BFP Citizens Charter & Standard Inspection Procedures
8 Chapter 8: Fire Investigation - Law on Arson & Evidence
Law on Arson in the Philippines: Revised Penal Code Framework Prima Facie Evidence of Arson & Motive Determination Fire Origin & Cause Determination & Burn Patterns Evidence Collection, Chain of Custody & Rights of Accused Rules of Court: Admissibility of Evidence & Investigator Testimony BFP SOPs on Fire and Arson Investigation: Workflow, Reports & Documentation
9 Chapter 9: Administrative Matters - BFP Laws & Rules
Republic Act 6975 (DILG Act of 1990) & Creation of the BFP Republic Act 9263 (BFP Professionalization Act) & Rank Hierarchy Republic Act 9592 & Administrative Disciplinary Rules Civil Service Commission Rules & Code of Ethics (RA 6713)
Search & Rescue Operations, PPE & SCBA Safety
Key Takeaways Explain This Topic AI
Primary search is a rapid, systematic evaluation for live victims prior to fire control, whereas secondary search is a thorough, post-control search conducted by a fresh crew.
Emergency victim removal methods include blanket drags, firefighter drags, web strap drags, and cradle carries depending on victim status and smoke layer.
Structural PPE turnout gear consists of three critical layers: flame-resistant outer shell, liquid/steam moisture barrier, and insulating thermal liner.
Open-circuit positive pressure SCBA maintains positive facepiece pressure, requiring strict air management under the Rule of Thirds.
PASS devices sound automatic emergency alerts, and MAYDAY protocols activate a dedicated Rapid Intervention Team (RIT) using LUNAR reports.
Last updated: July 2026
Search & Rescue Operations, PPE & SCBA Safety
Protecting human life is the primary mission of the fire service. Fire officers must ensure search and rescue operations are conducted rapidly and systematically while maintaining strict responder safety through complete Personal Protective Equipment (PPE) ensembles, Self-Contained Breathing Apparatus (SCBA) air management, and Rapid Intervention Team (RIT) readiness.
Search & Rescue Operations
Search and rescue operations are divided into two distinct, sequential phases: +-------------------------------------------------------------------------+
- | SEARCH & RESCUE DUAL-PHASE PROTOCOL |
- | |
- | [PRIMARY SEARCH] --> Rapid, systematic search during active fire |
- | (Focus: High-risk areas & live victims) |
- | | |
- | v |
- | [SECONDARY SEARCH] --> Meticulous, post-fire-control search |
- | (Executed by a DIFFERENT fresh crew) |
- +-------------------------------------------------------------------------+
- Primary Search vs. Secondary Search
Primary Search: A rapid, systematic, and thorough search conducted before or during fire suppression operations to locate and rescue live victims. Search teams follow systematic wall-search patterns (right-hand or left-hand search), moving quickly through high-risk areas near bedrooms, exit hallways, and behind entry doors.
Secondary Search: A meticulous, exhaustive search conducted after the fire has been completely controlled and smoke has cleared. The secondary search must be performed by a different crew than the primary search team to ensure fresh eyes and an unbiased re-evaluation of every room and void space.
Victim Carry & Emergency Drag Techniques
When a victim is located in a hazardous atmosphere, firefighters must choose an appropriate rescue removal technique based on victim mobility, weight, smoke density, and available personnel:
Blanket Drag: Rolling an unconscious victim onto a blanket or coat and pulling the fabric along the floor. Excellent for single-firefighter rescue over smooth floors.
Firefighter Drag: Binding the victim's wrists together, placing their arms around the firefighter's neck, and crawling on hands and knees while dragging the victim beneath the firefighter's body in heavy smoke.
Webbing Strap Drag: Wrapping a commercial synthetic web strap around the victim's upper chest and shoulders to provide ergonomic leverage for rapid pulling.
Cradle-in-Arms Carry: Lifting children or lightweight adults by placing one arm under their knees and the other around their back.
Personal Protective Equipment (PPE) Turnout Ensemble
Structural firefighting turnout gear is engineered to protect personnel from radiant heat, direct flame contact, steam, water, liquid chemicals, and mechanical injuries. +-------------------------------------------------------------------------+
- | TURNOUT COAT & TROUSERS THREE-LAYER SYSTEM |
- | |
- | 1. Outer Shell --> Flame resistance & abrasion protection (Nomex) |
- | 2. Moisture Barrier--> Liquid, steam & chemical protection (Gore-Tex) |
- | 3. Thermal Liner --> Insulates body against conductive heat transfer |
- +-------------------------------------------------------------------------+
- Turnout Gear Layers & Components
Outer Shell: Woven flame-resistant synthetic fibers (e.g., Nomex, Kevlar, PBI). Provides physical resistance against direct flame, tearing, and abrasion.
Moisture Barrier: Middle breathable membrane (e.g., Gore-Tex). Prevents liquid water, hot steam, bloodborne pathogens, and hazardous chemicals from penetrating inward to skin.
Thermal Liner: Inner quilted fabric layer. Traps insulating dead air space to protect firefighters against severe conductive and convective heat transfer.
Head & Foot Protection: Helmet with face shield/goggles, Nomex protective hood (shielding neck and ears), firefighting gloves, and steel-toe/steel-shank protective boots.
Safety Alert: Soot accumulation on turnout gear carries toxic carcinogens (e.g., polycyclic aromatic hydrocarbons). Gross decontamination at scene and regular gear washing are mandatory to reduce cancer risks.
Self-Contained Breathing Apparatus (SCBA) & Air Management
Structural fires produce toxic combustion gases—including Carbon Monoxide (CO) , Hydrogen Cyanide (HCN) , and phosgene. Modern firefighters rely on Open-Circuit Positive Pressure SCBA to breathe.
SCBA Operational Mechanics
Open-Circuit Positive Pressure System: Compressed breathing air is delivered from an air cylinder through a two-stage regulator into the facepiece. The regulator maintains positive pressure inside the mask facepiece relative to the exterior atmosphere at all times. If the facepiece seal is slightly compromised, air leaks outward, preventing toxic external gases from entering.
Core Components: High-pressure air cylinder (2,216 psi to 4,500 psi rating), harness and backpack assembly, first-stage pressure reducer, second-stage mask-mounted regulator, and full facepiece with speaking diaphragm.
Air Management & The Rule of Thirds
Although air cylinders carry NFPA duration ratings (e.g., 30-minute or 45-minute cylinders), actual air consumption depends on firefighter physical exertion and stress. Heavy work typically exhausts a "30-minute" cylinder in 15 to 20 minutes .
Firefighters must manage air consumption using the Rule of Thirds :
First 1 / 3 1/3 1/3 of Air: Allocated for entering the structure and advancing to the work area.
Second 1 / 3 1/3 1/3 of Air: Allocated for conducting search, rescue, and suppression operations.
Final 1 / 3 1/3 1/3 of Air: Reserved strictly as an emergency reserve for exiting the building before low-air alarms sound. Total Air Volume = 1 3 Entry flow ⏟ Advance + 1 3 Tactical work ⏟ Suppression + 1 3 Emergency reserve ⏟ Egress \text{Total Air Volume} = \underbrace{\frac{1}{3} \text{ Entry flow}}_{\text{Advance}} + \underbrace{\frac{1}{3} \text{ Tactical work}}_{\text{Suppression}} + \underbrace{\frac{1}{3} \text{ Emergency reserve}}_{\text{Egress}} Total Air Volume = Advance 3 1 Entry flow + Suppression 3 1 Tactical work + Egress 3 1 Emergency reserve
- PASS Device, MAYDAY Protocols & Rapid Intervention Teams (RIT)
- Personal Alert Safety System (PASS)
A PASS Device is an electronic safety monitor integrated into the SCBA. If a firefighter remains motionless for 18 to 20 seconds , the device sounds a low-volume pre-alarm. If immobility continues for 30 seconds , the PASS emits a continuous, high-decibel (95+ dB) audible distress alarm accompanied by flashing LED lights. PASS devices can also be manually activated.
MAYDAY Protocols & LUNAR Reports
When a firefighter becomes trapped, lost, disoriented, low on air, or injured, they immediately declare a radio MAYDAY . Command clears all radio traffic to receive the distress report using the LUNAR mnemonic:
L - Location: Last known position inside the structure (e.g., second floor, division 2 east wall).
U - Unit: Engine or ladder company designation (e.g., Engine 5).
N - Name: Firefighter's name.
A - Assignment / Air: Operational task being performed and remaining SCBA air pressure.
R - Resources Needed: Specific equipment or assistance required (e.g., hose line, RIT bag, air cylinder, heavy extraction).
Rapid Intervention Team (RIT / RIC)
A Rapid Intervention Team (RIT) or Rapid Intervention Crew (RIC) is a dedicated, fully equipped crew positioned outside the hazard zone standing by exclusively to rescue lost or trapped firefighters . The RIT maintains specialized rescue gear—including a specialized RIT air bag (spare SCBA cylinder and universal air connection hose), search ropes, thermal imaging cameras, forcing tools, and wire cutters.