Study guide

Salvage Operations, Loss Control & Property Conservation

Fire Officer Examination FOE

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Introduction & Exam Overview

About the Fire Officer Examination How to Use This Study Guide

2 Chapter 2: General Ability - Verbal Reasoning

Fire Service Vocabulary, Synonyms & Antonyms Verbal Analogies and Standard English Grammar Spelling, Correct Usage, Idioms & Punctuation Reading Comprehension and Passage Analysis

3 Chapter 3: General Ability - Analytical & Numerical Reasoning

Deductive Logic and Categorical Syllogisms Spatial Reasoning & Fireground Situational Judgment Data Interpretation: Tables, Graphs & Fire Incident Statistics Fundamental Arithmetic & Hydraulics Flow Rates Ratio, Proportion & Basic Algebra Percentages, Averages & Work/Time Word Problems Geometry, Mensuration & Measurement Conversions

4 Chapter 4: Fire Suppression - Science & Extinguishing Agents

Fire Behavior, Chemistry of Combustion & Fire Tetrahedron Classes of Fire and Extinguishing Media Portable Fire Extinguishers: Types, Ratings, PASS & Maintenance Firefighting Foam: Concentrates, Proportioning & Application Water Supply Systems, Pressure & Fire Hydraulics

5 Chapter 5: Fire Suppression - Operations & Equipment

Pre-Fire Planning, Size-Up & Incident Command System Fire Attack Tactics, Ventilation & Overhaul Salvage Operations, Loss Control & Property Conservation Hose Lines, Nozzles, Ground Ladders & Forcible Entry Fire Apparatus, Pump Operations & Apparatus Positioning Search & Rescue Operations, PPE & SCBA Safety BFP Emergency Medical Services & Special Rescue Operations Hazardous Materials Incident Response & Mitigation

6 Chapter 6: Fire Safety & Prevention - Philippine Fire Code (RA 9514)

Republic Act 9514 (Fire Code of the Philippines 2008) Scope & Principles 2019 Revised IRR Enforcement, Administrative Sanctions & Closure Orders Fire Safety Inspection Certificate (FSIC) & FSEC Requirements Fire Code Fees, Taxes & the Collection of Fire Code Revenues

7 Chapter 7: Fire Safety & Prevention - Codes & Inspection SOPs

Means of Egress Specifications & Fire Protection Systems Philippine Electrical Code & Electrical Fire Hazards Hazardous Materials Classification & High-Risk Occupancies Fire Drills, Evacuation Planning, Fire Brigades & Public Fire Safety Education BFP Citizens Charter & Standard Inspection Procedures

8 Chapter 8: Fire Investigation - Law on Arson & Evidence

Law on Arson in the Philippines: Revised Penal Code Framework Prima Facie Evidence of Arson & Motive Determination Fire Origin & Cause Determination & Burn Patterns Evidence Collection, Chain of Custody & Rights of Accused Rules of Court: Admissibility of Evidence & Investigator Testimony BFP SOPs on Fire and Arson Investigation: Workflow, Reports & Documentation

9 Chapter 9: Administrative Matters - BFP Laws & Rules

Republic Act 6975 (DILG Act of 1990) & Creation of the BFP Republic Act 9263 (BFP Professionalization Act) & Rank Hierarchy Republic Act 9592 & Administrative Disciplinary Rules Civil Service Commission Rules & Code of Ethics (RA 6713)

Salvage Operations, Loss Control & Property Conservation

Key Takeaways Explain This Topic AI

Salvage protects undamaged property from water, smoke and heat during and after the fire; overhaul locates and extinguishes hidden fire to prevent rekindle.

Salvage runs concurrently with fire attack rather than after it, and appears with overhaul as the S and the O of the RECEO-VS priority sequence.

A single operating sprinkler head is stopped with a sprinkler stop or wedge; the system control valve is closed only on the Incident Commander's order, with a firefighter posted at the valve and the system restored before release.

One cubic metre of water weighs 1,000 kilograms, which is why trapped ceiling water is drained deliberately before it collapses onto undamaged stock.

Aggressive overhaul in the area of origin destroys burn patterns and physical evidence, so the investigator or the Fire and Arson Investigation Unit required by RA 11589 Section 4(d) controls the scene in a suspicious fire.

Last updated: July 2026

Salvage Operations, Loss Control & Property Conservation

Loss control has three elements: confinement of the fire, salvage of what the fire has not yet reached, and overhaul of what it has. The FOE tests salvage and overhaul as a distinguishable pair, and that distinction is the most reliable item in this part of the blueprint:

Salvage protects undamaged property during and after the fire. Overhaul finds and extinguishes hidden fire so the building does not rekindle.

Both appear in the RECEO-VS priority sequence, and both begin far earlier than most candidates assume — salvage runs concurrently with attack, not after it.

Salvage Overhaul

Purpose Prevent avoidable water, smoke, heat and physical damage to property the fire has not destroyed Locate and extinguish hidden fire in voids, walls, ceilings and contents

Timing Concurrent with fire attack, and continuing afterwards After knockdown, and after the investigator has worked the area of origin

Typical work Covers, catch-alls, water chutes, sprinkler stops, water removal, smoke removal, securing the building Opening walls and ceilings, pulling ceilings, moving stock, wetting down, thermal imaging

Risk if done badly Property loss the fire itself did not cause; owner and insurer complaints Rekindle, structural weakening, and destruction of the point of origin and physical evidence

Ends when Property is protected, water removed and the building secured No heat signature remains and the officer is satisfied there will be no rekindle

Pre-Loss Planning

Loss control is planned during the same fire safety inspections that produce the pre-fire plan. The plan should already name what must be protected first in each occupancy: pharmacy stock and patient records in a district hospital, the server room and uninterruptible power supply room on a business-process-outsourcing floor, the vault and ledgers in a rural bank, images and vestments in a parish church, enrolment records in a public school, and stall inventories in a public market where hundreds of vendors carry no insurance at all.

Salvage Covers and Water Control

Salvage covers — heavy canvas or vinyl sheets — are the core tool, and crews must be able to deploy them fast, in the dark, with two people or one.

Rolled cover, one-firefighter deployment — the cover is rolled from one end and unrolled over the object; suitable for a single firefighter working alone over furniture or stock.

Accordion or triangular fold, two-firefighter deployment — the standard spread over a large area or a group of consolidated contents.

Balloon throw — two firefighters snap the cover open above the object so it settles over it without dragging across it.

Catch-all (basin) — a cover laid on the floor with its edges rolled inward to form a shallow basin under a leak, holding water until it can be pumped or drained. A catch-all is a stopgap; a chute is the fix.

Water chute — a cover supported on pike poles, ladders or furniture, forming a trough that carries running water out of a window, into a stairwell or to a floor drain.

Before covering, consolidate : move contents to the centre of the room away from walls and windows, stack them, raise them off the floor on pallets, chairs or dunnage, and only then cover. Covering a room full of scattered stock protects far less than grouping it first.

Sprinkler Control

Automatic sprinklers are loss-control allies, but a head still flowing over undamaged stock is itself a loss.

Stop the individual head with a sprinkler stop , wedge or sprinkler tongs , so the rest of the system continues protecting the building.

Close the system control valve only on the order of the Incident Commander , and only once the fire is confirmed controlled.

Post a firefighter at the valve with a radio, so protection can be restored in seconds if fire re-establishes.

Replace operating heads from the spare-head cabinet, re-open and lock the control valve , drain the low points, and notify the owner and the alarm monitoring company before the last unit leaves. Leaving a building with its sprinkler valve shut is an indefensible error.

Water Removal, Smoke Removal and Security

Water is heavier than examinees expect: one cubic metre weighs 1,000 kilograms . Water trapped above a suspended ceiling or standing on an upper floor threatens the contents and the structure at once.

Squeegee toward floor drains , and use submersible pumps for standing water.

Drain by gravity through scuppers, downspouts, toilet and floor drains , or through a small deliberate opening made where it does least damage, to release water pooled in a ceiling void before the ceiling collapses onto the stock beneath it.

Run negative-pressure ventilation after knockdown. Smoke residue is acidic and corrosive; the faster it is exhausted and surfaces are wiped or covered, the less electronics, appliances and merchandise are written off.

Secure the building against weather and looting — tarpaulin the roof, board or screen openings, and coordinate a cordon with the barangay tanod and the Philippine National Police until the owner takes custody. In dense urban fires this is not optional.

Salvage priority checklist

Life safety and structural stability first — no salvage work in an unsafe area.

Stop the water at its source: shut the nozzle, stop the head, close the valve.

Route water away from undamaged property before covering anything.

Consolidate, elevate, then cover.

Protect records, computers, cash, controlled drugs and irreplaceable or religious property; remove them from the building entirely when it is safe to do so.

Remove standing water and exhaust the smoke.

Secure the openings and the perimeter.

Document what was protected and what was damaged.

The Fire Investigation Interface

This is the highest-yield trap in the topic. Salvage and overhaul must not destroy the point of origin or physical evidence. Aggressive overhaul is a legitimate firefighting tactic and, done at the wrong moment, a reliable way to obliterate an arson case.

Do not shovel, move or wet down debris in the suspected area of origin until the fire investigator or the Fire and Arson Investigation unit has examined, photographed and documented it. RA 11589, Section 4(d) requires a Fire and Arson Investigation Unit in every region and city precisely so that this capability exists.

Where indicators of an intentionally set fire appear, the investigator controls the scene; the Incident Commander limits overhaul to what safety and rekindle prevention require, and carries that out under the investigator's direction.

Preserve burn patterns, low burns, protected areas beneath fallen debris, and any container or ignition device in place. Photograph before moving anything that must be moved.

Maintain scene security. The lawful basis for continued presence at the scene and the chain of custody for anything seized are examined in the investigation portion of the FOE; on the fireground your only job is to avoid destroying the evidence before the investigator arrives.

After the Fire: Occupants, Barangay and LGU

The BFP's obligations do not end at knockdown.

Fire watch. Leave a unit or a detail on scene for as long as the officer judges necessary, and re-check with a thermal imaging camera before release.

Scene release. Release the property to the owner or a lawful representative with written warnings about structural, electrical and liquefied petroleum gas (LPG) hazards, having coordinated with the electric distribution utility to cut service where needed.

Certification of Fire Incident. A BFP office may issue the applicable fire-incident certification for lawful uses such as insurance or assistance. Use the current office- and service-specific Citizen's Charter for the document name, responsible unit, processing time, requirements, and fee; do not treat an older peso amount or turnaround time as universal.

Displaced families. Coordinate immediately with the barangay, the City or Municipal Social Welfare and Development Office and the local Disaster Risk Reduction and Management Office for evacuation space — typically the barangay covered court — plus family food packs and non-food items, with Department of Social Welfare and Development augmentation tracked through its disaster response operations monitoring and information centre reports. In informal-settlement fires, where one incident can displace hundreds of families in minutes, this coordination is routine post-incident work for the fire officer, not an afterthought.