Study guide
7.4 Mass Spectrometry: Ionization Sources, Mass Analyzers, and Fragmentation Analysis
PRC Chemist Licensure Examination Exam
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Exam Overview, Chemistry Law (RA 10657), and Laboratory Safety
1.1 PRC Chemist Licensure Examination: Format, Schedule, Grading, and Passing Standards 1.2 Republic Act 10657 (Chemistry Profession Act) and Professional Ethics 1.3 Chemical Laboratory Safety, GHS Classification, Hazardous Waste Management, and Quality Assurance
2 Chapter 2: Inorganic Chemistry: Atomic Structure, Periodicity, and Chemical Bonding
2.1 Atoms, Ions, Compounds, Inorganic Nomenclature, and Stoichiometry 2.2 Quantum Numbers, Electronic Configurations, and Periodic Trends 2.3 Chemical Bonding Models: Lewis Structures, VSEPR Theory, and Molecular Polarity 2.4 Molecular Orbital Theory and Magnetochemistry of Diatomic Molecules
3 Chapter 3: Inorganic Chemistry: Coordination Compounds and Transition Metals
3.1 Coordination Chemistry: Nomenclature, Formulas, and Isomerism 3.2 Crystal Field Theory, Ligand Field Theory, d-Orbital Splitting, and Reaction Mechanisms 3.3 Electronic Absorption Spectra, Tanabe-Sugano Diagrams, and Magnetic Properties
4 Chapter 4: Inorganic Chemistry: Main Group, Reactivity, Solid State, Nuclear, and Applied Topics
4.1 Systematic Descriptive Chemistry of Main Group Elements (s- and p-Blocks) 4.2 Reactivity of Inorganic Compounds: Acid-Base Concepts, HSAB, and Redox Diagrams 4.3 Solid-State Chemistry: Crystal Systems, Unit Cells, and Band Theory 4.4 Bioinorganic Chemistry: Metalloproteins, Oxygen Carriers, and Metal Ion Toxicity 4.5 Organometallic Chemistry: 18-Electron Rule, Carbonyl Complexes, and Catalysis 4.6 Nuclear Chemistry: Stability, Decay, Transmutation, and Radioanalytical Methods 4.7 Industrial, Environmental, and Atmospheric Inorganic Chemistry and Advanced Materials
5 Chapter 5: Analytical Chemistry: Measurements, Statistics, Classical Wet Analysis, and Chemical Equilibria
5.1 Analytical Measurements: Apparatus, Units, Concentration, Sampling, and Sample Preparation 5.2 Analytical Data Evaluation: Errors, Uncertainty, Statistics, and Calibration 5.3 Gravimetric Analysis and Precipitation Equilibria ($K_{sp}$) 5.4 Neutralization Titrimetry, Polyprotic Systems, Buffers, and Alpha Fractions 5.5 Complexometric (EDTA), Redox, and Precipitation (Argentometric) Titrimetry
6 Chapter 6: Analytical Chemistry: Electroanalytical Methods and Separations
6.1 Potentiometry, Ion-Selective Electrodes, and Voltammetric Techniques 6.2 Analytical Separations: Solvent Extraction, SPE, Ion Exchange, Precipitation, Masking, and Electrodeposition 6.3 Fundamentals of Chromatography: Theoretical Plates, Resolution, and van Deemter Equation 6.4 Gas Chromatography (GC): Columns, Stationary Phases, Detectors, and Applications 6.5 High-Performance Liquid Chromatography (HPLC): Normal vs. Reversed Phase and Method Development
7 Chapter 7: Analytical Chemistry: Spectroscopic, Mass Spectrometric, and Other Instrumental Methods
7.1 Molecular UV-Vis Spectroscopy and Quantitative Beer-Lambert Law 7.2 Infrared (FTIR) and Raman Spectroscopy: Vibrational Modes and Instrumentation 7.3 Atomic Spectroscopy: Atomic Absorption (AAS) and Inductively Coupled Plasma (ICP-OES/MS) 7.4 Mass Spectrometry: Ionization Sources, Mass Analyzers, and Fragmentation Analysis 7.5 Other Instrumental Methods (XRF, Flame Emission, CE, SFC, Thermal Analysis, Electronics) and Method Selection
8 Chapter 8: Physical Chemistry: Gases, Thermodynamics, and Thermochemistry
8.1 Ideal and Real Gases and the Kinetic Molecular Theory 8.2 First Law of Thermodynamics: Heat, Work, Internal Energy, and Enthalpy 8.3 Second and Third Laws of Thermodynamics: Entropy, Carnot Engine, and Absolute Entropies 8.4 Gibbs and Helmholtz Free Energy, Spontaneity, and Fundamental Equations 8.5 Chemical Potential, Partial Molar Quantities, Fugacity, and Activity
9 Chapter 9: Physical Chemistry: Equilibrium, Phase Equilibria, Solutions, and Electrochemistry
9.1 Chemical Equilibrium: Equilibrium Constants, Le Chatelier's Principle, and the van 't Hoff Equation 9.2 Phase Rule, Phase Diagrams of One- and Two-Component Systems, and Clausius-Clapeyron Equation 9.3 Solutions: Raoult's and Henry's Laws, Colligative Properties, and Electrolytes 9.4 Electrochemistry: Galvanic Cells, Standard Potentials, and the Nernst Equation 9.5 Electrolyte Conductance, Ionic Mobility, Transport Numbers, and Concentration Cells
10 Chapter 10: Physical Chemistry: Kinetics, Surface Chemistry, and Quantum Mechanics
10.1 Reaction Rates, Rate Laws, and Integrated Rate Equations 10.2 Temperature Dependence of Rates: Arrhenius Equation, Collision Theory, and Transition State Theory 10.3 Reaction Mechanisms: Steady-State Approximation, Chain Reactions, and Catalysis 10.4 Surface Chemistry, Adsorption Isotherms, Colloids, and Macromolecular Solutions 10.5 Postulates of Quantum Mechanics, Operators, Particle in a Box, and Harmonic Oscillator 10.6 Atomic Spectra, the Hydrogen Atom, Many-Electron Atoms, and Term Symbols
11 Chapter 11: Organic Chemistry: Structure, Stereochemistry, and Hydrocarbons
11.1 Systematic IUPAC Nomenclature and Conformational Analysis of Alkanes and Cycloalkanes 11.2 Stereochemistry: Chirality, Enantiomers, Diastereomers, (R)/(S) Configuration, and Optical Activity 11.3 Alkenes and Alkynes: Addition Reactions, Markovnikov Rule, and Stereospecificity 11.4 Aromaticity: Hückel's Rule, Electrophilic Aromatic Substitution, and Directing Effects
12 Chapter 12: Organic Chemistry: Functional Groups, Mechanisms, Synthesis, and Structure Elucidation
12.1 Nucleophilic Aliphatic Substitution ($S_N1$, $S_N2$) and Elimination ($E_1$, $E_2$) Mechanisms 12.2 Alcohols, Phenols, Ethers, and Epoxides: Structure, Synthesis, and Reactivity 12.3 Carbonyl Compounds I: Aldehydes and Ketones, Nucleophilic Addition, and Oxidation/Reduction 12.4 Carbonyl Compounds II: Carboxylic Acids and Derivatives, Enolate Chemistry, and Condensations 12.5 Amines: Basicity, Synthesis, Reactions, and Arenediazonium Chemistry 12.6 Structure Elucidation: NMR Spectroscopy, Combined Spectral Problems, and Qualitative Organic Tests 12.7 Organic Synthesis Strategy, Protecting Groups, Rearrangements, and Pericyclic Reactions
13 Chapter 13: Biochemistry: Cells, Biomolecules, Enzymes, and Membranes
13.1 Cells, Organelles, Water, and Biological Acid-Base Buffers 13.2 Amino Acids, Peptides, and Hierarchical Protein Structure 13.3 Protein Purification and Biochemical Analysis of Proteins, Carbohydrates, and Lipids 13.4 Enzyme Nomenclature and Classification, Cofactors, Coenzymes, and Vitamin Precursors 13.5 Enzyme Kinetics: Michaelis-Menten Model, Lineweaver-Burk Analysis, and Enzyme Inhibition 13.6 Carbohydrates, Lipids, Biological Membranes, and Membrane Transport
14 Chapter 14: Biochemistry: Metabolism, Bioenergetics, Photosynthesis, and Molecular Genetics
14.1 Carbohydrate Catabolism and Anabolism: Glycolysis, Gluconeogenesis, Glycogen, and Pentose Phosphate Pathway 14.2 Citric Acid Cycle, Mitochondrial Electron Transport, Oxidative Phosphorylation, and $\beta$-Oxidation 14.3 Photosynthesis: Light Reactions, Photophosphorylation, and the Calvin Cycle 14.4 Lipolysis and Lipid Biosynthesis: Fatty Acids, Triacylglycerols, and Cholesterol 14.5 Nitrogen Metabolism: Nitrogen Fixation, Amino Acid Metabolism, and the Urea Cycle 14.6 Nucleic Acids, DNA Replication, Transcription, Translation, and Recombinant DNA Techniques 14.7 Regulation of Gene Expression, Mutation and Mutagens, DNA Repair, Carcinogenesis, and cDNA Cloning
7.4 Mass Spectrometry: Ionization Sources, Mass Analyzers, and Fragmentation Analysis
Key Takeaways Explain This Topic AI
Mass spectrometry measures mass-to-charge ratios ( m / z m/z m / z ) of gas-phase ions under high vacuum ( 10 − 5 − 10 − 7 torr 10^{-5}-10^{-7}\text{ torr} 1 0 − 5 − 1 0 − 7 torr ) to maintain mean free paths ( > 1 m \,>1\text{ m} > 1 m ) exceeding instrument dimensions.
Electron Ionization (EI) is a hard source ( 70 eV 70\text{ eV} 70 eV ) that transfers 2 − 7 eV 2-7\text{ eV} 2 − 7 eV of internal energy, producing extensive, reproducible unimolecular fragmentation matched against standardized NIST/Wiley spectral libraries.
Soft ionization methods (CI, ESI, APCI, MALDI) minimize excess internal energy, yielding intact protonated pseudomolecular ions ( [ M + H ] + [M+H]^+ [ M + H ] + ); ESI produces multiply charged ions ( [ M + z H ] z + [M+zH]^{z+} [ M + zH ] z + ), bringing macromolecules ( > 100 kDa >100\text{ kDa} > 100 kDa ) into the m / z m/z m / z range of quadrupole analyzers.
Mass analyzers vary in physics: Quadrupoles use combined DC/RF fields as mass filters; Time-of-Flight (TOF) separates ions by drift velocity ( t ∝ m / z t \propto \sqrt{m/z} t ∝ m / z ) with reflectrons for kinetic energy focusing; Orbitraps use harmonic axial oscillation frequencies ( ω z ∝ z / m \omega_z \propto \sqrt{z/m} ω z ∝ z / m ) for ultra-high resolution ( R > 100 , 000 R > 100,000 R > 100 , 000 ).
Tandem mass spectrometry (MS/MS in QqQ) uses Collision-Induced Dissociation (CID) and Selected/Multiple Reaction Monitoring (SRM/MRM) for trace quantitative bioanalysis.
Last updated: October 2026
7.4 Mass Spectrometry: Ionization Sources, Mass Analyzers, and Fragmentation Analysis
Quick Answer: Mass spectrometry (MS) vaporizes, ionizes, and separates gas-phase analyte ions according to their mass-to-charge ratio ( m / z m/z m / z ). High vacuum ( 10 − 5 − 10 − 7 torr 10^{-5}-10^{-7}\text{ torr} 1 0 − 5 − 1 0 − 7 torr ) is mandatory to ensure the mean free path ( > 1 m \,>1\text{ m} > 1 m ) exceeds the physical dimensions of the flight corridor. Ionization sources range from "hard" Electron Ionization (EI, 70 eV 70\text{ eV} 70 eV ), which induces reproducible fragmentation for NIST library matching, to "soft" techniques (ESI, MALDI, CI) that preserve intact pseudomolecular ions ( [ M + H ] + [M+H]^+ [ M + H ] + ). ESI produces multiply charged ions ( [ M + z H ] z + [M+zH]^{z+} [ M + zH ] z + ) allowing analysis of mega-Dalton proteins. Mass analyzers encompass unit-resolution Quadrupoles, high-speed Time-of-Flight (TOF with reflectron), and ultra-high-resolution Orbitraps ( R > 100 , 000 R > 100,000 R > 100 , 000 ). Spectral interpretation relies on the Nitrogen Rule, isotopic doublets ( 3 : 1 3:1 3 : 1 for C l Cl Cl , 1 : 1 1:1 1 : 1 for B r Br B r ), α \alpha α -cleavage, and the McLafferty rearrangement.
Vacuum Fundamentals and Mean Free Path
Mass spectrometers must operate under high vacuum ( 10 − 5 10^{-5} 1 0 − 5 to 10 − 7 torr 10^{-7}\text{ torr} 1 0 − 7 torr ; 10 − 3 10^{-3} 1 0 − 3 to 10 − 5 Pa 10^{-5}\text{ Pa} 1 0 − 5 Pa ) to prevent collisions between ions and background atmospheric gas molecules ( N 2 , O 2 , H 2 O N_2, O_2, H_2O N 2 , O 2 , H 2 O ). Collisions cause scattering, kinetic energy loss, charge neutralization, and peak broadening.
Mean Free Path ( λ \lambda λ ): The average distance an ion travels between successive collisions with background gas molecules: λ = k B T 2 π d 2 P \lambda = \frac{k_B \, T}{\sqrt{2} \, \pi \, d^2 \, P} λ = 2 π d 2 P k B T where k B k_B k B is the Boltzmann constant ( 1.381 × 10 − 23 J/K 1.381 \times 10^{-23}\text{ J/K} 1.381 × 1 0 − 23 J/K ), T T T is temperature, d d d is collision diameter ( ∼ 0.4 nm \sim 0.4\text{ nm} ∼ 0.4 nm ), and P P P is pressure. At atmospheric pressure ( 760 torr 760\text{ torr} 760 torr ), λ ≈ 57 nm \lambda \approx 57\text{ nm} λ ≈ 57 nm . At 10 − 6 torr 10^{-6}\text{ torr} 1 0 − 6 torr , λ ≈ 43 meters \lambda \approx 43\text{ meters} λ ≈ 43 meters , easily exceeding analyzer dimensions ( 0.5 − 2 m 0.5-2\text{ m} 0.5 − 2 m ), ensuring collision-free flight.
Vacuum Pumping Train: Differential pumping uses mechanical roughing pumps (rotary vane or scroll pumps, achieving 10 − 2 − 10 − 3 torr 10^{-2}-10^{-3}\text{ torr} 1 0 − 2 − 1 0 − 3 torr ) backing high-vacuum turbomolecular pumps (bladed turbines rotating at 60 , 000 − 90 , 000 rpm 60,000-90,000\text{ rpm} 60 , 000 − 90 , 000 rpm ) or oil diffusion pumps.
Ionization Sources: Hard vs. Soft Ionization Ionization Energy Spectrum:
- Hard Ionization (High Internal Energy: 2-7 eV) Soft Ionization (<1 eV Internal Energy)
- [ Electron Ionization (EI) ] [ CI, ESI, APCI, MALDI ]
- |
- v |
- Extensive Fragmentation: v
M+•, [M-15]+, [M-28]+, fragments Intact Pseudomolecular Ions:
- (NIST Library Fingerprinting) [M+H]+, [M+Na]+, [M-H]- (Intact MW)
- 1. Hard Ionization: Electron Ionization (EI)
Mechanism: Volatile neutral sample molecules enter an ionization chamber under high vacuum ( 10 − 5 torr 10^{-5}\text{ torr} 1 0 − 5 torr ). A heated tungsten or rhenium filament emits thermal electrons accelerated through a 70 V 70\text{ V} 70 V potential, acquiring 70 eV 70\text{ eV} 70 eV of kinetic energy ( 1.12 × 10 − 17 J 1.12 \times 10^{-17}\text{ J} 1.12 × 1 0 − 17 J ).
The 70 eV 70\text{ eV} 70 eV Standard: The de Broglie wavelength of a 70 eV 70\text{ eV} 70 eV electron is: λ = h p = h 2 m e E ≈ 0.14 nm \lambda = \frac{h}{p} = \frac{h}{\sqrt{2 m_e E}} \approx 0.14\text{ nm} λ = p h = 2 m e E h ≈ 0.14 nm This wavelength closely matches typical covalent bond lengths in organic molecules ( 0.12 − 0.15 nm 0.12-0.15\text{ nm} 0.12 − 0.15 nm ), maximizing wave interaction and orbital resonance. Collision expels a valence electron, forming a radical cation: M + e − ( 70 eV ) ⟶ M + ∙ + 2 e − M + e^-(70\text{ eV}) \longrightarrow M^{+\bullet} + 2e^- M + e − ( 70 eV ) ⟶ M +∙ + 2 e −
Because typical molecular ionization potentials are 7 − 12 eV 7-12\text{ eV} 7 − 12 eV , a 70 eV 70\text{ eV} 70 eV impact imparts substantial excess internal vibrational energy ( 2 − 7 eV 2-7\text{ eV} 2 − 7 eV ). This drives reproducible unimolecular fragmentation via bond cleavages and rearrangements. Because spectra acquired at 70 eV 70\text{ eV} 70 eV are instrument-independent, unknowns can be matched against standard spectral libraries (NIST, Wiley > 1 , 000 , 000 >1,000,000 > 1 , 000 , 000 spectra). Limitation: The intact molecular ion ( M + ∙ M^{+\bullet} M +∙ ) is often undetectable for labile or branched compounds.
2. Soft Ionization Techniques
Chemical Ionization (CI):
A reagent gas (methane, isobutane, or ammonia) is introduced into the source at high pressure ( ∼ 1 torr \sim 1\text{ torr} ∼ 1 torr ). Energetic electrons ionize the reagent gas, producing reactive carbocations (e.g., C H 4 + e − → C H 4 + ∙ + 2 e − CH_4 + e^- \rightarrow CH_4^{+\bullet} + 2e^- C H 4 + e − → C H 4 +∙ + 2 e − ; C H 4 + ∙ + C H 4 → C H 5 + + C H 3 ∙ CH_4^{+\bullet} + CH_4 \rightarrow CH_5^+ + CH_3^\bullet C H 4 +∙ + C H 4 → C H 5 + + C H 3 ∙ ).
Analyte molecules ( M M M ) undergo gas-phase proton transfer with the reagent acid: M + C H 5 + ⟶ [ M + H ] + + C H 4 M + CH_5^+ \longrightarrow [M+H]^+ + CH_4 M + C H 5 + ⟶ [ M + H ] + + C H 4
Because proton transfer is gently exothermic, the resulting pseudomolecular ion [ M + H ] + [M+H]^+ [ M + H ] + possesses minimal excess internal energy ( < 1 eV <1\text{ eV} < 1 eV ), yielding an abundant [ M + H ] + [M+H]^+ [ M + H ] + peak with negligible fragmentation, confirming nominal molecular weight.
Electrospray Ionization (ESI):
Operates at atmospheric pressure for polar, non-volatile macromolecules (peptides, proteins, oligonucleotides).
Sample solution is pumped ( 1 − 1000 μ L/min 1-1000\text{ }\mu\text{L/min} 1 − 1000 μ L/min ) through a stainless steel capillary held at high voltage ( 3 − 5 kV 3-5\text{ kV} 3 − 5 kV ). Electrostatic repulsion creates a cone of liquid (the Taylor cone ), which emits a fine mist of positively (or negatively) charged droplets.
Heated nitrogen desolvation gas evaporates solvent, causing droplets to contract. As droplet radius ( R R R ) shrinks, surface charge density increases until electrostatic Coulombic repulsion overcomes surface tension ( γ \gamma γ ) at the Rayleigh stability limit : q R = 8 π ϵ 0 γ R 3 q_R = 8\pi \sqrt{\epsilon_0 \, \gamma \, R^3} q R = 8 π ϵ 0 γ R 3
Reaching the Rayleigh limit triggers Coulomb explosion (droplet fission) , yielding charged microdroplets. Gas-phase ions emerge via the Ion Evaporation Model (IEM) for small molecules or the Charge Residue Model (CRM) for folded proteins. Electrospray Ionization (ESI) Desolvation and Ion Emission:
Capillary (+3-5 kV) Taylor Cone Coulomb Fissions Gas-Phase Ions
=======\ . ' .
- \ o o o : o : [M + zH]^(z+)
- > =====> o o o ========> . ' . ' . ========> (Multiple Charging!)
/ o o o : o :
=======/ (Evaporation) . ' .
Multiple Charging in ESI and Mathematical Deconvolution
Proteins and peptides acquire multiple protons on basic residues (Arg, Lys, His) and terminal amines, forming multiply charged ions ( [ M + z H ] z + [M+zH]^{z+} [ M + zH ] z + ). Because mass spectrometers measure mass-to-charge ratio ( m / z m/z m / z ), multiple charging shifts high-mass analytes ( M > 100 , 000 Da M > 100,000\text{ Da} M > 100 , 000 Da ) into the modest m / z m/z m / z range ( 500 − 2000 500-2000 500 − 2000 ) of benchtop quadrupole analyzers.
Deconvolution Formula: For two adjacent peaks in an ESI charge-state envelope at m 1 m_1 m 1 and m 2 m_2 m 2 ( m 1 < m 2 m_1 < m_2 m 1 < m 2 ), where m 1 m_1 m 1 carries charge z 1 z_1 z 1 and m 2 m_2 m 2 carries charge z 2 = z 1 − 1 z_2 = z_1 - 1 z 2 = z 1 − 1 : m 1 = M + z 1 ( 1.008 ) z 1 , m 2 = M + ( z 1 − 1 ) ( 1.008 ) z 1 − 1 m_1 = \frac{M + z_1(1.008)}{z_1}, \quad m_2 = \frac{M + (z_1 - 1)(1.008)}{z_1 - 1} m 1 = z 1 M + z 1 ( 1.008 ) , m 2 = z 1 − 1 M + ( z 1 − 1 ) ( 1.008 ) Solving for the charge of the lower m / z m/z m / z peak ( z 1 z_1 z 1 ): z 1 = m 2 − 1.008 m 2 − m 1 z_1 = \frac{m_2 - 1.008}{m_2 - m_1} z 1 = m 2 − m 1 m 2 − 1.008 M = z 1 ( m 1 − 1.008 ) M = z_1(m_1 - 1.008) M = z 1 ( m 1 − 1.008 )
Atmospheric Pressure Chemical Ionization (APCI): Sample solution is sprayed into a heated quartz desolvation chamber ( 350 − 500 ∘ C 350-500^\circ\text{C} 350 − 50 0 ∘ C ), completely vaporizing solvent and analyte. A corona discharge needle ( 2 − 4 kV 2-4\text{ kV} 2 − 4 kV ) ionizes solvent molecules, which chemically ionize the analyte via proton transfer. Well suited for moderately polar, lower molecular weight compounds ( < 1500 Da <1500\text{ Da} < 1500 Da ) that do not ionize cleanly by ESI.
Matrix-Assisted Laser Desorption/Ionization (MALDI): Analyte is co-crystallized with a vast molar excess ( 1 : 1000 1:1000 1 : 1000 to 1 : 10000 1:10000 1 : 10000 ) of a small, UV-absorbing organic matrix (e.g., sinapinic acid for proteins, α \alpha α -cyano-4-hydroxycinnamic acid [CHCA] for peptides, 2,5-dihydroxybenzoic acid [DHB] for glycans). A pulsed UV laser (nitrogen laser at 337 nm 337\text{ nm} 337 nm or Nd:YAG at 355 nm 355\text{ nm} 355 nm ) irradiates the sample. The matrix absorbs laser photons, desorbs as an expanding supersonic plume, and transfers protons to the analyte. MALDI produces predominantly singly charged ions ( [ M + H ] + [M+H]^+ [ M + H ] + ) , simplifying complex mixture interpretation.
Mass Analyzers: Physical Operating Principles
Analyzer Type Governing Separation Physics Resolving Power ( m / Δ m m/\Delta m m /Δ m ) Mass Range ( m / z m/z m / z ) Characteristics & Best Applications
Quadrupole (Q) Combined DC ( U U U ) and RF ( V 0 cos ω t V_0\cos\omega t V 0 cos ω t ) electric field stability Unit resolution ( 1 , 000 − 3 , 000 1,000-3,000 1 , 000 − 3 , 000 ) Up to 3 , 000 3,000 3 , 000 Fast scan speeds, low cost, robust; standard in GC-MS, LC-MS/MS quantitation
Time-of-Flight (TOF) Ion drift velocity in field-free tube: t ∝ m / z t \propto \sqrt{m/z} t ∝ m / z 20 , 000 − 60 , 000 20,000-60,000 20 , 000 − 60 , 000 (with reflectron) Theoretically unlimited ( > 100 , 000 >100,000 > 100 , 000 ) Pulsed acquisition, high speed (full spectra in μ s \mu\text{s} μ s ); ideal for MALDI, LC-TOF profiling
Orbitrap Axial harmonic oscillation frequency: ω z ∝ z / m \omega_z \propto \sqrt{z/m} ω z ∝ z / m 100 , 000 − 500 , 000 100,000-500,000 100 , 000 − 500 , 000 Up to 6 , 000 6,000 6 , 000 Ultra-high resolution, electrostatic trapping (no superconducting magnet); proteomics/metabolomics
FT-ICR Ion cyclotron orbital frequency in high magnetic field ( B B B ): ω c = z e B m \omega_c = \frac{z e B}{m} ω c = m ze B > 1 , 000 , 000 >1,000,000 > 1 , 000 , 000 Up to 10 , 000 10,000 10 , 000 Highest resolution and mass accuracy ( < 0.5 ppm <0.5\text{ ppm} < 0.5 ppm ); high cost, requires cryogenic liquid He/N2
1. The Quadrupole Mass Filter
Four parallel hyperbolic or cylindrical metal rods. Opposite pairs are linked electrically: one pair receives a potential of + ( U + V 0 cos ω t ) +(U + V_0 \cos\omega t) + ( U + V 0 cos ω t ) , while the adjacent pair receives − ( U + V 0 cos ω t ) -(U + V_0 \cos\omega t) − ( U + V 0 cos ω t ) , where U U U is a direct current (DC) voltage and V 0 cos ω t V_0 \cos\omega t V 0 cos ω t is a radiofrequency (RF) alternating voltage.
Ion trajectories are modeled by the Mathieu differential equations using dimensionless stability parameters a u a_u a u and q u q_u q u : a u = 8 z e U m r 0 2 ω 2 , q u = 4 z e V 0 m r 0 2 ω 2 a_u = \frac{8 \, z \, e \, U}{m \, r_0^2 \, \omega^2}, \quad q_u = \frac{4 \, z \, e \, V_0}{m \, r_0^2 \, \omega^2} a u = m r 0 2 ω 2 8 z e U , q u = m r 0 2 ω 2 4 z e V 0
For a specific ratio of U / V 0 U/V_0 U / V 0 , only ions within a narrow window of m / z m/z m / z maintain a stable oscillating trajectory through the central corridor to reach the detector. All other ions oscillate with unstable amplitudes, strike the rods, discharge, and are pumped away. Sweeping U U U and V 0 V_0 V 0 at a constant ratio produces a continuous mass spectrum.
2. Time-of-Flight (TOF) Mass Analyzer and the Reflectron
Ions are accelerated from the ion source by an electric potential V V V ( 15 − 30 kV 15-30\text{ kV} 15 − 30 kV ), imparting identical kinetic energy ( E k E_k E k ):
z e V = 1 2 m v 2 ⟹ v = 2 z e V m z \, e \, V = \frac{1}{2} m \, v^2 \implies v = \sqrt{\frac{2 \, z \, e \, V}{m}} z e V = 2 1 m v 2 ⟹ v = m 2 z e V
Ions enter a field-free drift flight tube of length L L L . Flight time ( t t t ) to the detector is:
t = L v = L m 2 z e V = k m z t = \frac{L}{v} = L \sqrt{\frac{m}{2 \, z \, e \, V}} = k \sqrt{\frac{m}{z}} t = v L = L 2 z e V m = k z m
Lighter ions travel faster and arrive at the detector first.
The Reflectron (Ion Mirror): In simple linear TOF, identical ions possess small initial kinetic energy distributions ( Δ E k \Delta E_k Δ E k ), causing peak broadening. An electrostatic reflectron consists of ring electrodes establishing a retarding electrical field at the end of the drift tube. Ions with higher kinetic energy penetrate deeper into the retarding field before reversing direction, while slower ions turn around sooner. By tuning the reflectron voltage, faster ions spend more time in the mirror, allowing slower ions to catch up at the detector focal plane, sharpening peak widths and increasing resolving power from R ≈ 1 , 000 R \approx 1,000 R ≈ 1 , 000 to R > 30 , 000 R > 30,000 R > 30 , 000 .
3. Resolving Power and Mass Accuracy
Mass Resolving Power ( R R R ): The capacity to separate adjacent peaks, defined under the Full Width at Half Maximum (FWHM) convention: R = m Δ m 50 % R = \frac{m}{\Delta m_{50\%}} R = Δ m 50% m
Mass Accuracy (in ppm): Measures deviation of experimental mass from theoretical exact mass: Mass Error (ppm) = m experimental − m theoretical m theoretical × 10 6 \text{Mass Error (ppm)} = \frac{m_{\text{experimental}} - m_{\text{theoretical}}}{m_{\text{theoretical}}} \times 10^6 Mass Error (ppm) = m theoretical m experimental − m theoretical × 1 0 6 High-resolution instruments ( < 3 − 5 ppm <3-5\text{ ppm} < 3 − 5 ppm ) eliminate false elemental formulas, confirming exact chemical formulas.
Tandem Mass Spectrometry (MS/MS) and Scan Modes
A Triple Quadrupole (QqQ) consists of three quadrupoles in series: Q1 (precursor ion filter) → \rightarrow → q2 (collision cell filled with N 2 N_2 N 2 or A r Ar A r , RF-only) → \rightarrow → Q3 (product ion filter).
Collision-Induced Dissociation (CID): Selected precursor ions are accelerated into collision cell q2, colliding with inert gas atoms ( N 2 N_2 N 2 ). Translational kinetic energy converts into internal vibrational energy, inducing unimolecular fragmentation into product ions. Triple Quadrupole (QqQ) Scan Modes:
- 1. Product Ion Scan: [ Q1: Fixed Precursor ] --> [ q2: CID ] --> [ Q3: Scan All Products ]
- 2. Precursor Ion Scan: [ Q1: Scan All Precursors] -> [ q2: CID ] --> [ Q3: Fixed Diagnostic Product ]
- 3. Neutral Loss Scan: [ Q1: Scan ] --> [ q2: CID ] --> [ Q3: Scan with Fixed Offset Δm ]
- 4. MRM / SRM Mode: [ Q1: Fixed Precursor ] --> [ q2: CID ] --> [ Q3: Fixed Fragment Product ]
Selected / Multiple Reaction Monitoring (SRM / MRM): Q1 is set to transmit solely the precursor ion, and Q3 is set to transmit solely a unique diagnostic fragment ion. By rejecting all chemical noise and co-eluting matrix interferents, MRM provides the highest sensitivity and selectivity for quantitative pharmaceutical and clinical assays.
- Spectral Interpretation: Rules and Fragmentation Mechanisms
- 1. The Molecular Ion ( M + ∙ M^{+\bullet} M +∙ ) and the Nitrogen Rule
The Nitrogen Rule: An organic molecule composed solely of C , H , O , S , P C, H, O, S, P C , H , O , S , P , and halogens with an odd nominal molecular weight must contain an odd number of nitrogen atoms ( 1 , 3 , 5 … 1, 3, 5\dots 1 , 3 , 5 … ). A molecule with an even nominal molecular weight contains an even number of nitrogen atoms ( 0 , 2 , 4 … 0, 2, 4\dots 0 , 2 , 4 … ).
Exam Trap: This rule applies to radical cations ( M + ∙ M^{+\bullet} M +∙ ) generated in EI. For protonated pseudomolecular ions ( [ M + H ] + [M+H]^+ [ M + H ] + ) produced in soft ionization (ESI/CI), the rule is inverted (e.g., an intact compound with 1 nitrogen has an odd M M M , so [ M + H ] + [M+H]^+ [ M + H ] + appears at an even m / z m/z m / z !).
2. Isotopic Signatures: Chlorine, Bromine, and Carbon
The M + 1 M+1 M + 1 Peak (Carbon Estimation): Carbon exists naturally as 12 C ^{12}C 12 C ( 98.9 % 98.9\% 98.9% ) and 13 C ^{13}C 13 C ( 1.08 % ≈ 1.1 % 1.08\% \approx 1.1\% 1.08% ≈ 1.1% ). The number of carbon atoms ( n n n ) in an unknown compound is estimated from the intensity ratio of the M + 1 M+1 M + 1 peak to the molecular ion ( M + ∙ M^{+\bullet} M +∙ ): n = % ( M + 1 ) % ( M + ∙ ) × 1.1 % × 100 n = \frac{\%(M+1)}{\%(M^{+\bullet}) \times 1.1\%} \times 100 n = % ( M +∙ ) × 1.1% % ( M + 1 ) × 100
The M + 2 M+2 M + 2 Peak (Halogen Signatures):
Chlorine: Naturally occurs as 35 C l ^{35}Cl 35 Cl ( 75.8 % 75.8\% 75.8% ) and 37 C l ^{37}Cl 37 Cl ( 24.2 % 24.2\% 24.2% ), yielding an unmistakable 3 : 1 3:1 3 : 1 intensity ratio between M M M and M + 2 M+2 M + 2 .
Bromine: Naturally occurs as 79 B r ^{79}Br 79 B r ( 50.7 % 50.7\% 50.7% ) and 81 B r ^{81}Br 81 B r ( 49.3 % 49.3\% 49.3% ), yielding an unmistakable 1 : 1 1:1 1 : 1 doublet of nearly equal height separated by 2 Da 2\text{ Da} 2 Da ( M : M + 2 ≈ 100 : 98 M : M+2 \approx 100 : 98 M : M + 2 ≈ 100 : 98 ).
Sulfur: 34 S ^{34}S 34 S ( 4.2 % 4.2\% 4.2% ) exhibits a characteristic M + 2 M+2 M + 2 peak equal to ∼ 4.4 % \sim 4.4\% ∼ 4.4% of the molecular ion.
Halogen Content Isotopic Pattern ( M : M + 2 : M + 4 : M + 6 M : M+2 : M+4 : M+6 M : M + 2 : M + 4 : M + 6 ) Characteristic Peak Intensity Ratio
1 × C l 1 \times Cl 1 × Cl M : M + 2 M : M+2 M : M + 2 3 : 1 3 : 1 3 : 1 ( 100 % : 32.5 % 100\% : 32.5\% 100% : 32.5% )
2 × C l 2 \times Cl 2 × Cl M : M + 2 : M + 4 M : M+2 : M+4 M : M + 2 : M + 4 9 : 6 : 1 9 : 6 : 1 9 : 6 : 1 ( 100 % : 65 % : 10.6 % 100\% : 65\% : 10.6\% 100% : 65% : 10.6% )
3 × C l 3 \times Cl 3 × Cl M : M + 2 : M + 4 : M + 6 M : M+2 : M+4 : M+6 M : M + 2 : M + 4 : M + 6 27 : 27 : 9 : 1 27 : 27 : 9 : 1 27 : 27 : 9 : 1
1 × B r 1 \times Br 1 × B r M : M + 2 M : M+2 M : M + 2 1 : 1 1 : 1 1 : 1 ( 100 % : 98 % 100\% : 98\% 100% : 98% )
2 × B r 2 \times Br 2 × B r M : M + 2 : M + 4 M : M+2 : M+4 M : M + 2 : M + 4 1 : 2 : 1 1 : 2 : 1 1 : 2 : 1 ( 50 % : 100 % : 50 % 50\% : 100\% : 50\% 50% : 100% : 50% )
1 × C l + 1 × B r 1 \times Cl + 1 \times Br 1 × Cl + 1 × B r M : M + 2 : M + 4 M : M+2 : M+4 M : M + 2 : M + 4 3 : 4 : 1 3 : 4 : 1 3 : 4 : 1 ( 75 % : 100 % : 25 % 75\% : 100\% : 25\% 75% : 100% : 25% )
3. Core Fragmentation Mechanisms
α \alpha α -Cleavage: Homolytic cleavage of a bond adjacent to a heteroatom bearing an unpaired electron (carbonyls, alcohols, ethers, amines). The heteroatom lone pair stabilizes the resulting oxonium or iminium cation by forming a double bond: R 2 C H − O + ∙ − R ′ → α -cleavage R ∙ + [ R − C H = O + − R ′ ] R_2CH-\overset{+\bullet}{O}-R' \xrightarrow{\alpha\text{-cleavage}} R^\bullet + [R-CH=\overset{+}{O}-R'] R 2 C H − O +∙ − R ′ α -cleavage R ∙ + [ R − C H = O + − R ′ ] Largest-radical rule: If multiple alkyl groups can be cleaved, the largest alkyl radical is usually expelled preferentially because radical stability increases: methyl < 1 ∘ < 2 ∘ < 3 ∘ < 1^\circ < 2^\circ < 3^\circ < 1 ∘ < 2 ∘ < 3 ∘ .
The McLafferty Rearrangement: A site-specific intramolecular rearrangement of an odd-electron molecular ion containing an unsaturated functional group ( C = O , C = N , C = C C=O, C=N, C=C C = O , C = N , C = C ) and a hydrogen atom on the γ \gamma γ -carbon .
Mechanism: The radical cation forms a planar six-membered cyclic transition state . The γ \gamma γ -hydrogen transfers to the carbonyl oxygen, accompanied by homolytic cleavage of the β \beta β -bond ( C α − C β C_\alpha - C_\beta C α − C β ).
Products: Cleavage expels a neutral alkene molecule ( C n H 2 n C_n H_{2n} C n H 2 n ) and leaves behind a resonance-stabilized enol radical cation ( O E + ∙ OE^{+\bullet} O E +∙ ): [ R − C H ( γ ) − C H 2 ( β ) − C H 2 ( α ) − C O − R ′ ] + ∙ ⟶ R − C H = C H 2 (neutral) + [ C H 2 = C ( O H ) R ′ ] + ∙ [R-CH(\gamma)-CH_2(\beta)-CH_2(\alpha)-CO-R']^{+\bullet} \longrightarrow R-CH=CH_2 \text{ (neutral)} + [CH_2=C(OH)R']^{+\bullet} [ R − C H ( γ ) − C H 2 ( β ) − C H 2 ( α ) − CO − R ′ ] +∙ ⟶ R − C H = C H 2 (neutral) + [ C H 2 = C ( O H ) R ′ ] +∙
Diagnostic McLafferty Enol Product Ions:
Aliphatic methyl ketones ( C H 3 − C O − C H 2 − C H 2 − C H 2 − R CH_3-CO-CH_2-CH_2-CH_2-R C H 3 − CO − C H 2 − C H 2 − C H 2 − R ): Base peak at m / z = 58 m/z = 58 m / z = 58 ( [ C H 2 = C ( O H ) C H 3 ] + ∙ [CH_2=C(OH)CH_3]^{+\bullet} [ C H 2 = C ( O H ) C H 3 ] +∙ ).
Aliphatic aldehydes ( H − C O − C H 2 − C H 2 − C H 2 − R H-CO-CH_2-CH_2-CH_2-R H − CO − C H 2 − C H 2 − C H 2 − R ): Diagnostic peak at m / z = 44 m/z = 44 m / z = 44 ( [ C H 2 = C H − O H ] + ∙ [CH_2=CH-OH]^{+\bullet} [ C H 2 = C H − O H ] +∙ ).
Methyl esters of carboxylic acids: Base peak at m / z = 74 m/z = 74 m / z = 74 ( [ C H 2 = C ( O H ) O C H 3 ] + ∙ [CH_2=C(OH)OCH_3]^{+\bullet} [ C H 2 = C ( O H ) OC H 3 ] +∙ ).
Unsubstituted carboxylic acids: Diagnostic peak at m / z = 60 m/z = 60 m / z = 60 ( [ C H 2 = C ( O H ) 2 ] + ∙ [CH_2=C(OH)_2]^{+\bullet} [ C H 2 = C ( O H ) 2 ] +∙ ).