Study guide
6.7 Construction Trades and Specialties: Plumbing, Plastics, Doors and Windows, Finishes, and Electrical
PRC Civil Engineer Licensure Examination CELE
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Examination Overview, RA 544 & Professional Practice
1.1 CELE Structure, Format, Scoring, and 2026 Subject Order 1.2 Republic Act No. 544: The Civil Engineering Law and Board Regulations 1.3 Civil Engineering Ethics, Contracts, and Professional Practice
2 Chapter 2: Engineering Mathematics, Numerical Methods & Physics
2.1 Advanced Algebra, Progressions & Word Problems 2.2 Trigonometry and Analytical Geometry 2.3 Differential and Integral Calculus 2.4 Differential Equations and Numerical Methods 2.5 Series, Hyperbolic Functions, Multivariable Calculus, and Laplace Transforms 2.6 Numerical Methods: Linear Systems, Interpolation, Curve Fitting, and ODE Solvers 2.7 Physics for Engineers: Kinematics, Newton's Laws, Work-Energy, and Momentum
3 Chapter 3: Engineering Data Analysis & Engineering Economy
3.1 Engineering Data Analysis and Statistical Applications 3.2 Parameter Estimation, Linear Regression, Correlation, and Queuing Models 3.3 Engineering Economy: Time Value of Money and Interest Formulas 3.4 Project Evaluation, Depreciation, and Benefit-Cost Analysis
4 Chapter 4: Surveying Fundamentals, Construction Layout & Route Surveying
4.1 Errors, Corrections, and Pacing/Taping 4.2 Leveling, Earthworks, and Mass Haul Diagrams 4.3 Traverse Computations, Balancing, and Area Determinations 4.4 Route Surveying: Horizontal and Vertical Curves
5 Chapter 5: Highway & Transportation Engineering
5.1 Highway Geometric Design and Sight Distances 5.2 Traffic Engineering, Flow Fundamentals, and Pavement Design 5.3 Highway Policy, Route Location, Drainage, and Earthwork Slopes 5.4 Transportation Planning, Network Analysis, and Intermodal Systems
6 Chapter 6: Construction Materials, Methods, Management & Safety
6.1 Materials for Construction: Concrete, Formwork, Masonry, Steel, and Wood Products 6.2 Construction Equipment, Formwork, and Construction Methods 6.3 Construction Occupational Safety and Health: RA 11058 and DOLE DO 13 6.4 Construction Project Management, CPM/PERT, and Resource Scheduling 6.5 Construction Principles: Design Requirements, Project Organization, Cost Control, and Value Engineering 6.6 Quantity Surveying, Unit Cost Analysis, and Project Cost Estimates 6.7 Construction Trades and Specialties: Plumbing, Plastics, Doors and Windows, Finishes, and Electrical
7 Chapter 7: Fluid Properties, Hydrostatics & Buoyancy
7.1 Fluid Properties, Units, and Pressure Measurement 7.2 Hydrostatic Pressure on Plane and Curved Surfaces 7.3 Buoyancy, Flotation, and Accelerated Fluid Masses
8 Chapter 8: Hydrodynamics, Pipe Flow, Open Channels & Water Supply
8.1 Fluid Dynamics: Continuity and Energy Equations 8.2 Flow Measurement: Orifices, Weirs, and Venturi Meters 8.3 Fluid Flow in Pipes, Friction Losses, and Pipe Networks 8.4 Open Channel Flow, Manning's Equation, and Hydraulic Jump 8.5 Water Supply: Demand, Storage, Pumping, Distribution, and Treatment
9 Chapter 9: Soil Properties, Seepage & Stresses in Soil Mass
9.1 Soil Composition, Weight-Volume Phase Relationships 9.2 Soil Classification Systems (USCS & AASHTO) and Atterberg Limits 9.3 Soil Permeability, Seepage, Flow Nets, and Effective Stress 9.4 Stresses in Soil Mass, Stress Distribution, and Immediate and Secondary Settlement
10 Chapter 10: Consolidation, Soil Strength, Earth Pressures & Foundations
10.1 Soil Compaction and Soil Compressibility/Consolidation 10.2 Shear Strength of Soils and Mohr-Coulomb Failure Criteria 10.3 Lateral Earth Pressures (Rankine & Coulomb) and Retaining Walls 10.4 Shallow and Deep Foundation Bearing Capacity and Slope Stability
11 Chapter 11: Engineering Mechanics & Statics
11.1 Force Systems, Resultants, and Equilibrium of Rigid Bodies 11.2 Centroids, Moments of Inertia, and Friction 11.3 Cables, Trusses, and Internal Forces in Members
12 Chapter 12: Strength of Materials
12.1 Axial Stress, Strain, and Deformation 12.2 Torsion, Flanged Bolt Couplings, and Thin-Walled Pressure Vessels 12.3 Beam Stresses: Flexural and Transverse Shear 12.4 Beam Deflections, Combined Stresses, and Mohr's Circle
13 Chapter 13: Structural Analysis & NSCP Load Criteria
13.1 Indeterminate Structures: Approximate and Classical Methods 13.2 Moment Distribution Method and Slope Deflection 13.3 Influence Lines for Determinate and Indeterminate Structures 13.4 NSCP Minimum Design Loads: Dead, Live, Wind, and Earthquake
14 Chapter 14: Reinforced Concrete Design (NSCP 2015 / USD)
14.1 Ultimate Strength Design (USD) Principles and Singly Reinforced Beams 14.2 Doubly Reinforced Beams and T-Beams 14.3 Shear and Diagonal Tension, Stirrup Design, and Development Length 14.4 Reinforced Concrete Columns and Isolated Footing Design
15 Chapter 15: Steel, Timber & Prestressed Design and Materials Testing
15.1 Structural Steel Tension Members and Connections 15.2 Structural Steel Compression Members and Beam Design 15.3 Timber Design Principles, Working Stress, and Sawn Lumber Beams 15.4 Prestressed Concrete Fundamentals and Prestress Losses 15.5 Construction Materials Testing and Concrete Mix Proportioning
6.7 Construction Trades and Specialties: Plumbing, Plastics, Doors and Windows, Finishes, and Electrical
Key Takeaways Explain This Topic AI
Every plumbing fixture needs a trap with a water seal, and a vent system that keeps the seal from being siphoned.
CPVC and PPR pipes are rated for hot water, while ordinary uPVC is used for cold water and drainage.
Tempered glass breaks into small blunt pieces, while laminated glass is held together by its interlayer when broken.
Paint systems are applied as surface preparation, primer, intermediate coats and finish, each compatible with the substrate.
Branch-circuit conductors are sized for at least 125% of continuous load and protected by a circuit breaker matched to the conductor ampacity.
Last updated: October 2026
6.7 Construction Trades and Specialties: Plumbing, Plastics, Doors and Windows, Finishes, and Electrical
The AMSTHC TOS area "Construction Trades and Specialties" has five one-item competencies:
Recall basic plumbing design, construction and installation.
Classify and determine plastics for construction.
Select details of doors and windows for proper application.
Identify and select finishing materials.
Understand basic electrical design, construction and installation.
Civil engineers coordinate these trades and are expected to know their vocabulary and basic rules. The governing codes are:
- the National Plumbing Code of the Philippines , under the Plumbing Law (RA 1378);
- the Philippine Electrical Code (PEC Part 1, under the Electrical Engineering Law, RA 7920);
the Fire Code (RA 9514) for fire-rated doors.
Plumbing Basics
System Components Key rules
Water supply Service connection, water meter, gate valves, risers, branches, storage tank, booster pump Size pipes for peak demand and residual pressure; prevent backflow with air gaps or check valves
Drainage (sanitary) Fixture drains, traps, branch drains, soil and waste stacks, building drain and sewer Grade horizontal drains at about 2% (1:50) for small pipes; provide cleanouts at changes of direction
Venting Vent pipes from fixture traps to the vent stack and roof Keeps air pressure balanced so trap seals are not siphoned or blown out
- Storm drainage Gutters, downspouts, catch basins Kept separate from sanitary drainage
- Private disposal Septic tank with leaching field Sized for population; two compartments; watertight
Traps. A P-trap holds a water seal , typically about 50 to 100 mm deep, that blocks sewer gas. Seal loss is caused by siphonage (inadequate venting), evaporation (unused fixtures) and back-pressure.
Drainage fixture units express the relative discharge load of fixtures; pipe sizes are chosen from code tables based on total fixture units.
Common pipe materials:
- uPVC for cold water, drainage and vents;
- CPVC or PPR for hot water;
- galvanized iron (older systems);
- copper;
HDPE for service lines and underground mains.
Plastics in Construction
Plastic Main uses Notes
PVC / uPVC (polyvinyl chloride) Cold water and drainage pipes, electrical conduit, window frames Rigid; joined by solvent cement; not for hot water
- CPVC (chlorinated PVC) Hot and cold water pipes Higher temperature rating than PVC
- PPR (polypropylene random copolymer) Hot and cold water Joined by heat fusion, giving leak-free joints
PE / HDPE (polyethylene) Water mains, gas lines, geomembranes, vapor barriers Flexible and tough; butt- or electro-fusion joints
- Polycarbonate Skylights, roofing sheets High impact strength; needs UV protection
- Acrylic (PMMA) Glazing, signage Clear, but scratches more easily
Fiber-reinforced plastic (FRP) Tanks, gratings, strengthening wraps for concrete High strength-to-weight ratio; corrosion resistant
Expanded and extruded polystyrene Insulation, lightweight fill Combustible; must be protected
Thermoplastics (PVC, PE, PP) soften when heated and can be reshaped or welded. Thermosets (epoxy, polyester, phenolic) cure permanently. Plastics expand far more with temperature than steel, so long runs need expansion allowances. Many degrade in sunlight unless UV-stabilized.
Doors and Windows
Door parts:
- the frame or jamb (head and side jambs, with a threshold at the floor);
- the leaf or shutter ;
- the stop ;
the hardware : hinges, lockset, closer, panic bar.
Window parts:
- the frame (head, jambs, sill);
- the sash ;
- mullions (vertical dividers) and transoms (horizontal dividers);
glazing .
- Type Typical application
- Swing (hinged) door Rooms, exits; exit doors swing in the direction of travel
- Sliding door or window Limited swing space
- Folding or accordion door Wide openings
- Casement window (side-hinged) Good ventilation, tight seal
- Awning (top-hinged) or jalousie window Ventilation in rain; jalousies are common in tropical houses
- Fire door (labeled, self-closing) Exit stairs, rated walls under the Fire Code
Glazing options:
Annealed float glass is the basic type and breaks into sharp shards.
Tempered glass is about four to five times stronger and breaks into small blunt pieces. It is required in hazardous locations such as doors and low panels.
Laminated glass keeps its interlayer intact when broken; it is used in overhead and security glazing.
Insulating glass units improve thermal performance.
Aluminum and uPVC frames resist rot. Wood needs treatment and finishing. All windows need proper sill slope and flashing to shed water.
Finishing Materials
- Element Common materials Selection points
- Walls Cement plaster with paint; ceramic tiles; stone; wall panels Moisture exposure, cleanability, impact
Floors Ceramic or porcelain tiles, granite, terrazzo, vinyl, epoxy, polished concrete, wood Abrasion, slip resistance (wet areas), loads, maintenance
- Ceilings Gypsum board, fiber-cement board, acoustic tiles on metal grid Fire rating, humidity, acoustics
- Roofing Pre-painted metal sheets, tiles, waterproofing membranes for flat roofs Slope, wind uplift, corrosion
Waterproofing Cementitious coatings, bituminous or liquid membranes Toilets, roof decks, basements, water tanks
Paint systems follow a sequence: surface preparation (clean and repair; let new concrete or plaster cure and dry), primer or sealer, putty or skim coat where needed, then two or more finish coats. Alkali-resistant primers are used on new masonry. Epoxy or polyurethane systems are used for chemical or heavy-wear areas.
Basic Electrical Design and Installation
The Philippine Electrical Code (PEC Part 1) governs building wiring. Houses are typically served at a nominal 220–230 V single-phase , and larger buildings by three-phase services.
Concept Rule of practice
Power P = V I cos ϕ P = VI\cos\phi P = V I cos ϕ for single-phase loads ( cos ϕ \cos\phi cos ϕ is the power factor)
Branch circuits Separate circuits for lighting, convenience outlets and large appliances (air conditioners, water heaters)
- Conductor sizing Ampacity at least the load current, and at least 125% of continuous loads
- Overcurrent protection Circuit breaker rating not exceeding the conductor ampacity
- Voltage drop Commonly limited to about 3% in a branch circuit and 5% overall
- Grounding and bonding Equipment grounding conductor to every outlet and metal enclosure
- Raceways Rigid steel, intermediate metal, EMT, or PVC conduit with boxes and fittings
Example. A 2.0 kW 2.0\text{ kW} 2.0 kW air conditioner on 230 V 230\text{ V} 230 V with power factor 0.85 0.85 0.85 draws I = 2,000 / ( 230 × 0.85 ) = 10.2 A I = 2{,}000/(230 \times 0.85) = 10.2\text{ A} I = 2 , 000/ ( 230 × 0.85 ) = 10.2 A . Treated as a continuous load, the circuit needs 1.25 ( 10.2 ) = 12.8 A 1.25(10.2) = 12.8\text{ A} 1.25 ( 10.2 ) = 12.8 A of conductor capacity. The conductor size and breaker rating are then selected from the PEC ampacity tables for the insulation type and installation method.