Study guide
10.4 Shallow and Deep Foundation Bearing Capacity and Slope Stability
PRC Civil Engineer Licensure Examination CELE
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Examination Overview, RA 544 & Professional Practice
1.1 CELE Structure, Format, Scoring, and 2026 Subject Order 1.2 Republic Act No. 544: The Civil Engineering Law and Board Regulations 1.3 Civil Engineering Ethics, Contracts, and Professional Practice
2 Chapter 2: Engineering Mathematics, Numerical Methods & Physics
2.1 Advanced Algebra, Progressions & Word Problems 2.2 Trigonometry and Analytical Geometry 2.3 Differential and Integral Calculus 2.4 Differential Equations and Numerical Methods 2.5 Series, Hyperbolic Functions, Multivariable Calculus, and Laplace Transforms 2.6 Numerical Methods: Linear Systems, Interpolation, Curve Fitting, and ODE Solvers 2.7 Physics for Engineers: Kinematics, Newton's Laws, Work-Energy, and Momentum
3 Chapter 3: Engineering Data Analysis & Engineering Economy
3.1 Engineering Data Analysis and Statistical Applications 3.2 Parameter Estimation, Linear Regression, Correlation, and Queuing Models 3.3 Engineering Economy: Time Value of Money and Interest Formulas 3.4 Project Evaluation, Depreciation, and Benefit-Cost Analysis
4 Chapter 4: Surveying Fundamentals, Construction Layout & Route Surveying
4.1 Errors, Corrections, and Pacing/Taping 4.2 Leveling, Earthworks, and Mass Haul Diagrams 4.3 Traverse Computations, Balancing, and Area Determinations 4.4 Route Surveying: Horizontal and Vertical Curves
5 Chapter 5: Highway & Transportation Engineering
5.1 Highway Geometric Design and Sight Distances 5.2 Traffic Engineering, Flow Fundamentals, and Pavement Design 5.3 Highway Policy, Route Location, Drainage, and Earthwork Slopes 5.4 Transportation Planning, Network Analysis, and Intermodal Systems
6 Chapter 6: Construction Materials, Methods, Management & Safety
6.1 Materials for Construction: Concrete, Formwork, Masonry, Steel, and Wood Products 6.2 Construction Equipment, Formwork, and Construction Methods 6.3 Construction Occupational Safety and Health: RA 11058 and DOLE DO 13 6.4 Construction Project Management, CPM/PERT, and Resource Scheduling 6.5 Construction Principles: Design Requirements, Project Organization, Cost Control, and Value Engineering 6.6 Quantity Surveying, Unit Cost Analysis, and Project Cost Estimates 6.7 Construction Trades and Specialties: Plumbing, Plastics, Doors and Windows, Finishes, and Electrical
7 Chapter 7: Fluid Properties, Hydrostatics & Buoyancy
7.1 Fluid Properties, Units, and Pressure Measurement 7.2 Hydrostatic Pressure on Plane and Curved Surfaces 7.3 Buoyancy, Flotation, and Accelerated Fluid Masses
8 Chapter 8: Hydrodynamics, Pipe Flow, Open Channels & Water Supply
8.1 Fluid Dynamics: Continuity and Energy Equations 8.2 Flow Measurement: Orifices, Weirs, and Venturi Meters 8.3 Fluid Flow in Pipes, Friction Losses, and Pipe Networks 8.4 Open Channel Flow, Manning's Equation, and Hydraulic Jump 8.5 Water Supply: Demand, Storage, Pumping, Distribution, and Treatment
9 Chapter 9: Soil Properties, Seepage & Stresses in Soil Mass
9.1 Soil Composition, Weight-Volume Phase Relationships 9.2 Soil Classification Systems (USCS & AASHTO) and Atterberg Limits 9.3 Soil Permeability, Seepage, Flow Nets, and Effective Stress 9.4 Stresses in Soil Mass, Stress Distribution, and Immediate and Secondary Settlement
10 Chapter 10: Consolidation, Soil Strength, Earth Pressures & Foundations
10.1 Soil Compaction and Soil Compressibility/Consolidation 10.2 Shear Strength of Soils and Mohr-Coulomb Failure Criteria 10.3 Lateral Earth Pressures (Rankine & Coulomb) and Retaining Walls 10.4 Shallow and Deep Foundation Bearing Capacity and Slope Stability
11 Chapter 11: Engineering Mechanics & Statics
11.1 Force Systems, Resultants, and Equilibrium of Rigid Bodies 11.2 Centroids, Moments of Inertia, and Friction 11.3 Cables, Trusses, and Internal Forces in Members
12 Chapter 12: Strength of Materials
12.1 Axial Stress, Strain, and Deformation 12.2 Torsion, Flanged Bolt Couplings, and Thin-Walled Pressure Vessels 12.3 Beam Stresses: Flexural and Transverse Shear 12.4 Beam Deflections, Combined Stresses, and Mohr's Circle
13 Chapter 13: Structural Analysis & NSCP Load Criteria
13.1 Indeterminate Structures: Approximate and Classical Methods 13.2 Moment Distribution Method and Slope Deflection 13.3 Influence Lines for Determinate and Indeterminate Structures 13.4 NSCP Minimum Design Loads: Dead, Live, Wind, and Earthquake
14 Chapter 14: Reinforced Concrete Design (NSCP 2015 / USD)
14.1 Ultimate Strength Design (USD) Principles and Singly Reinforced Beams 14.2 Doubly Reinforced Beams and T-Beams 14.3 Shear and Diagonal Tension, Stirrup Design, and Development Length 14.4 Reinforced Concrete Columns and Isolated Footing Design
15 Chapter 15: Steel, Timber & Prestressed Design and Materials Testing
15.1 Structural Steel Tension Members and Connections 15.2 Structural Steel Compression Members and Beam Design 15.3 Timber Design Principles, Working Stress, and Sawn Lumber Beams 15.4 Prestressed Concrete Fundamentals and Prestress Losses 15.5 Construction Materials Testing and Concrete Mix Proportioning
10.4 Shallow and Deep Foundation Bearing Capacity and Slope Stability
Key Takeaways Explain This Topic AI
Terzaghi's ultimate bearing capacity equation for continuous strip footings is qult = c Nc + q Nq + 0.5 γ B Nγ, modified by specific shape factors for square (1.3c Nc + q Nq + 0.4 γ B Nγ) and circular footings (1.3c Nc + q Nq + 0.3 γ B Nγ).
Groundwater table proximity reduces bearing capacity: a water table within depth Df modifies surcharge q, while a water table within depth B below the footing base reduces the third unit-weight term toward buoyant unit weight γ'.
Deep foundation pile capacity combines end-bearing and shaft friction (Qult = qp Ap + ∑ fs As); for cohesive soils, end bearing is qp = 9 cu, while skin friction is governed by the α-method (fs = α cu).
In pile group design, capacity is governed by the smaller of individual pile capacity summation (with Converse-Labarre efficiency) and monolithic block failure capacity.
Slope stability evaluation requires distinct models: infinite slopes depend on friction and seepage ratios (FS = [γ'/γsat] * [tan φ'/tan β]), while finite slopes are analyzed via Swedish circle (φ = 0), Ordinary Method of Slices, or Bishop's Simplified method (FS ≥ 1.5).
Last updated: October 2026
10.4 Shallow and Deep Foundation Bearing Capacity and Slope Stability
Foundation design bridges structural engineering and soil mechanics. Structural engineers must proportion structural footings and deep piles to transmit superstructure column loads into underlying soil strata without exceeding the shear strength of the supporting ground or causing excessive differential settlement. Furthermore, natural and engineered slopes must be stabilized against catastrophic gravitational mass wasting.
Terzaghi's Bearing Capacity Theory for Shallow Foundations
A shallow foundation is defined as one where the embedment depth is less than or equal to its width ( D f ≤ B D_f \le B D f ≤ B ). In 1943, Karl Terzaghi published the classical ultimate bearing capacity equation for a continuous strip footing based on general shear failure: Column Load P
- |
- +---+---+
- Ground Surface | | Ground Surface
- ----------------+ Df +-----------------
- | |
- +-------+ Footing Base (Width B)
- /| I |\
- / | | \
- / +-------+ \
- / / \ \
- / II/ \II \
- / / \ \
- +---+ +---+
- <------- Zone III ------->
General shear failure divides the underlying soil mass into three distinct behavioral zones:
Zone I (Triangular Elastic Wedge): Directly under the base, pushes downward into the soil as a rigid body.
Zone II (Radial Shear Zone): Plastic shear zones along log-spiral boundaries.
Zone III (Rankine Passive Linear Wedge): Pushed upward against the surcharge overburden.
General Form for Continuous Strip Footings
q ult = c N c + q N q + 1 2 γ B N γ q_{\text{ult}} = c N_c + q N_q + \frac{1}{2} \gamma B N_\gamma q ult = c N c + q N q + 2 1 γ B N γ Where:
- c c c = soil cohesion ( kPa \text{kPa} kPa )
- q = γ D f q = \gamma D_f q = γ D f = effective surcharge at foundation base level ( kPa \text{kPa} kPa )
- γ \gamma γ = unit weight of soil supporting the base wedge ( kN/m 3 \text{kN/m}^3 kN/m 3 )
- B B B = footing width (shortest lateral dimension, m \text{m} m )
N c , N q , N γ N_c, N_q, N_\gamma N c , N q , N γ = dimensionless Terzaghi bearing capacity factors, which depend purely on the internal friction angle ϕ \phi ϕ : N q = e 2 ( 3 π / 4 − ϕ / 2 ) tan ϕ 2 cos 2 ( 45 ∘ + ϕ / 2 ) N_q = \frac{e^{2(3\pi/4 - \phi/2)\tan \phi}}{2 \cos^2(45^\circ + \phi/2)} N q = 2 c o s 2 ( 4 5 ∘ + ϕ /2 ) e 2 ( 3 π /4 − ϕ /2 ) t a n ϕ N c = ( N q − 1 ) cot ϕ ( for ϕ = 0 ∘ , N c = 5.7 ) N_c = (N_q - 1) \cot \phi \quad (\text{for } \phi = 0^\circ, N_c = 5.7) N c = ( N q − 1 ) cot ϕ ( for ϕ = 0 ∘ , N c = 5.7 ) N γ ≈ 1 2 ( K p γ cos 2 ϕ − 1 ) tan ϕ N_\gamma \approx \frac{1}{2} \left( \frac{K_{p\gamma}}{\cos^2\phi} - 1 \right) \tan \phi N γ ≈ 2 1 ( c o s 2 ϕ K p γ − 1 ) tan ϕ
For saturated clays under undrained conditions ( ϕ = 0 ∘ \phi = 0^\circ ϕ = 0 ∘ ): N c = 5.7 , N q = 1.0 , N γ = 0 N_c = 5.7, \quad N_q = 1.0, \quad N_\gamma = 0 N c = 5.7 , N q = 1.0 , N γ = 0 q ult = 5.7 c u + q q_{\text{ult}} = 5.7 c_u + q q ult = 5.7 c u + q
Footing Shape Modifications
To adapt the 2D strip footing equation to 3D isolated footings, empirical shape coefficients are applied:
Footing Geometry Terzaghi Ultimate Bearing Capacity Equation ( q ult q_{\text{ult}} q ult )
Continuous Strip q ult = c N c + q N q + 0.5 γ B N γ q_{\text{ult}} = c N_c + q N_q + 0.5 \gamma B N_\gamma q ult = c N c + q N q + 0.5 γ B N γ
Square ( B × B B \times B B × B ) q ult = 1.3 c N c + q N q + 0.4 γ B N γ q_{\text{ult}} = 1.3 c N_c + q N_q + 0.4 \gamma B N_\gamma q ult = 1.3 c N c + q N q + 0.4 γ B N γ
Circular (Diameter B B B ) q ult = 1.3 c N c + q N q + 0.3 γ B N γ q_{\text{ult}} = 1.3 c N_c + q N_q + 0.3 \gamma B N_\gamma q ult = 1.3 c N c + q N q + 0.3 γ B N γ
Rectangular ( B × L B \times L B × L ) q ult = c N c ( 1 + 0.3 B L ) + q N q + 0.5 γ B N γ ( 1 − 0.2 B L ) q_{\text{ult}} = c N_c \left(1 + 0.3 \frac{B}{L}\right) + q N_q + 0.5 \gamma B N_\gamma \left(1 - 0.2 \frac{B}{L}\right) q ult = c N c ( 1 + 0.3 L B ) + q N q + 0.5 γ B N γ ( 1 − 0.2 L B )
General Bearing Capacity Equation (Meyerhof, Hansen, Vesic)
For footings subjected to inclined loads, deep embedment, or eccentricities, the General Bearing Capacity Equation incorporates shape ( s s s ), depth ( d d d ), and load inclination ( i i i ) factors: q ult = c N c s c d c i c + q N q s q d q i q + 1 2 γ B N γ s γ d γ i γ q_{\text{ult}} = c N_c s_c d_c i_c + q N_q s_q d_q i_q + \frac{1}{2} \gamma B N_\gamma s_\gamma d_\gamma i_\gamma q ult = c N c s c d c i c + q N q s q d q i q + 2 1 γ B N γ s γ d γ i γ
Groundwater Table Modifications
The presence of a high water table reduces effective stresses and diminishes bearing capacity: Case 1: Water at depth d_w <= D_f
- ------------------------- GWT (d_w)
- /////////// Submerged Overburden
- ---------- Footing Base (D_f)
- Case 2: Water at depth D_f < d_w <= D_f + B
- ---------- Footing Base (D_f)
- ........... Moist Wedge
- ------------------------- GWT (d_w)
- /////////// Submerged Wedge
- ------------------------- Depth D_f + B
Case 1: Groundwater Table Above Footing Base ( d w ≤ D f d_w \le D_f d w ≤ D f ):
Surcharge q q q becomes: q = γ d w + γ ′ ( D f − d w ) q = \gamma d_w + \gamma' (D_f - d_w) q = γ d w + γ ′ ( D f − d w )
Unit weight in third term becomes buoyant: γ = γ ′ = γ sat − γ w \gamma = \gamma' = \gamma_{\text{sat}} - \gamma_w γ = γ ′ = γ sat − γ w
Case 2: Groundwater Table Within Wedge Depth ( D f < d w ≤ D f + B D_f < d_w \le D_f + B D f < d w ≤ D f + B ):
Surcharge is unaffected: q = γ D f q = \gamma D_f q = γ D f
Unit weight in third term is an effective weighted average: γ ˉ = γ ′ + ( d w − D f B ) ( γ − γ ′ ) \bar{\gamma} = \gamma' + \left( \frac{d_w - D_f}{B} \right) (\gamma - \gamma') γ ˉ = γ ′ + ( B d w − D f ) ( γ − γ ′ )
Case 3: Groundwater Table Deep Below Base ( d w > D f + B d_w > D_f + B d w > D f + B ):
Water table has no physical effect on bearing capacity; use moist/dry γ \gamma γ in both terms.
Allowable Bearing Capacity & Factor of Safety
q all = q ult F S ( standard F S = 3.0 ) q_{\text{all}} = \frac{q_{\text{ult}}}{FS} \quad (\text{standard } FS = 3.0) q all = FS q ult ( standard FS = 3.0 ) Net Allowable Bearing Capacity: q all,net = q ult − q F S \text{Net Allowable Bearing Capacity: } q_{\text{all,net}} = \frac{q_{\text{ult}} - q}{FS} Net Allowable Bearing Capacity: q all,net = FS q ult − q Allowable Column Load: P all = q all × A footing \text{Allowable Column Load: } P_{\text{all}} = q_{\text{all}} \times A_{\text{footing}} Allowable Column Load: P all = q all × A footing
Deep Foundations: Piles and Drilled Shafts
When surficial soils are too weak or compressible to support shallow footings within tolerable settlement limits, structural loads are transferred to deeper, competent strata via deep foundations.
Ultimate Axial Pile Capacity
The ultimate compressive load capacity Q ult Q_{\text{ult}} Q ult of an isolated single pile is the sum of its base end-bearing resistance ( Q p Q_p Q p ) and shaft skin friction resistance ( Q s Q_s Q s ) : Q ult = Q p + Q s = q p A p + ∑ f s A s Q_{\text{ult}} = Q_p + Q_s = q_p A_p + \sum f_s A_s Q ult = Q p + Q s = q p A p + ∑ f s A s Where:
- A p A_p A p = cross-sectional area of the pile tip
- q p q_p q p = unit point bearing capacity
A s = p Δ L A_s = p \Delta L A s = p Δ L = surface area of pile shaft perimeter over length segment Δ L \Delta L Δ L
- f s f_s f s = unit skin friction (shaft resistance)
- Cohesive Soils (Clays)
End-Bearing ( Q p Q_p Q p ): For saturated clays under undrained conditions, N c ∗ = 9.0 N_c^* = 9.0 N c ∗ = 9.0 : q p = 9 c u ⟹ Q p = 9 c u A p q_p = 9 c_u \implies Q_p = 9 c_u A_p q p = 9 c u ⟹ Q p = 9 c u A p
Skin Friction ( Q s Q_s Q s ) — The α \alpha α -Method: f s = α c u ⟹ Q s = ∑ α c u p Δ L f_s = \alpha c_u \implies Q_s = \sum \alpha c_u p \Delta L f s = α c u ⟹ Q s = ∑ α c u p Δ L Where α \alpha α is the empirical adhesion factor (ranging from ≈ 1.0 \approx 1.0 ≈ 1.0 for soft clays down to 0.4 0.4 0.4 for stiff clays).
Cohesionless Soils (Sands)
End-Bearing ( Q p Q_p Q p ): q p = q ′ N q ∗ ≤ q limit q_p = q' N_q^* \le q_{\text{limit}} q p = q ′ N q ∗ ≤ q limit Where q ′ q' q ′ is the effective vertical stress at the pile tip (often capped at a critical depth L c ≈ 10 D to 20 D L_c \approx 10D \text{ to } 20D L c ≈ 10 D to 20 D ).
Skin Friction ( Q s Q_s Q s ) — The β \beta β -Method: f s = β σ v ′ = K tan δ σ v ′ f_s = \beta \sigma'_v = K \tan \delta \sigma'_v f s = β σ v ′ = K tan δ σ v ′ Where K K K is the lateral earth pressure coefficient and δ \delta δ is the interface friction angle.
Pile Group Efficiency & Block Failure
Piles are typically installed in clusters connected by a reinforced concrete pile cap. The ultimate capacity of a pile group containing n n n piles is governed by the lesser of:
Sum of Individual Capacities (with efficiency η \eta η ): Q group = η ⋅ n ⋅ Q ult,single Q_{\text{group}} = \eta \cdot n \cdot Q_{\text{ult,single}} Q group = η ⋅ n ⋅ Q ult,single Where the Converse-Labarre efficiency equation models group interaction: η = 1 − θ 90 ∘ [ ( n − 1 ) m + ( m − 1 ) n m ⋅ n ] \eta = 1 - \frac{\theta}{90^\circ} \left[ \frac{(n-1)m + (m-1)n}{m \cdot n} \right] η = 1 − 9 0 ∘ θ [ m ⋅ n ( n − 1 ) m + ( m − 1 ) n ] Where m m m is number of rows, n n n is number of columns, and θ = arctan ( d / s ) \theta = \arctan(d/s) θ = arctan ( d / s ) in degrees ( d = diameter , s = spacing d = \text{diameter}, s = \text{spacing} d = diameter , s = spacing ).
Block Failure Capacity ( Q block Q_{\text{block}} Q block ): The pile cluster and enclosed soil mass act as a single large monolithic pier of dimensions B g × L g B_g \times L_g B g × L g and depth L L L : Q block = 9 c u ( B g L g ) + 2 ( B g + L g ) L c u Q_{\text{block}} = 9 c_u (B_g L_g) + 2(B_g + L_g) L c_u Q block = 9 c u ( B g L g ) + 2 ( B g + L g ) L c u (Note: For block failure, soil shears along soil, so α = 1.0 \alpha = 1.0 α = 1.0 .)
Slope Stability Analysis
Slope failures occur when gravity-induced shear stresses along a potential sliding surface exceed the available shear strength of the soil.
1. Infinite Slopes (Translational Failure)
Applies to long, planar natural slopes where the depth of the active sliding layer H H H is small compared to slope length.
Cohesionless Soil ( c ′ = 0 c' = 0 c ′ = 0 ), Dry or No Seepage: F S = Resisting Shear Stress Driving Shear Stress = σ ′ tan ϕ ′ τ = γ H cos β tan ϕ ′ γ H sin β = tan ϕ ′ tan β FS = \frac{\text{Resisting Shear Stress}}{\text{Driving Shear Stress}} = \frac{\sigma' \tan \phi'}{\tau} = \frac{\gamma H \cos \beta \tan \phi'}{\gamma H \sin \beta} = \frac{\tan \phi'}{\tan \beta} FS = Driving Shear Stress Resisting Shear Stress = τ σ ′ t a n ϕ ′ = γ H s i n β γ H c o s β t a n ϕ ′ = t a n β t a n ϕ ′ The slope is stable against failure as long as slope angle β ≤ ϕ ′ \beta \le \phi' β ≤ ϕ ′ .
Cohesionless Soil with Steady Seepage Parallel to Slope (Water at Surface): F S = γ ′ γ sat tan ϕ ′ tan β ≈ 1 2 tan ϕ ′ tan β FS = \frac{\gamma'}{\gamma_{\text{sat}}} \frac{\tan \phi'}{\tan \beta} \approx \frac{1}{2} \frac{\tan \phi'}{\tan \beta} FS = γ sat γ ′ t a n β t a n ϕ ′ ≈ 2 1 t a n β t a n ϕ ′
Important
Steady seepage parallel to the slope face with water at the surface cuts the factor of safety roughly in half because buoyant unit weight γ ′ \gamma' γ ′ is approximately half of saturated unit weight γ sat \gamma_{\text{sat}} γ sat .
Cohesive-Frictional Soil ( c ′ − ϕ ′ c' - \phi' c ′ − ϕ ′ ): F S = c ′ γ H sin β cos β + tan ϕ ′ tan β FS = \frac{c'}{\gamma H \sin \beta \cos \beta} + \frac{\tan \phi'}{\tan \beta} FS = γ H s i n β c o s β c ′ + t a n β t a n ϕ ′
2. Finite Slopes (Rotational Circular Arc Failure)
Applies to engineered embankments, cuts, and retaining berms.
Swedish Circle / Mass Method ( ϕ = 0 ∘ \phi = 0^\circ ϕ = 0 ∘ Saturated Clay): F S = Resisting Moment Overturning Moment = c u L a R W ⋅ d = c u ( R θ ) R W ⋅ d FS = \frac{\text{Resisting Moment}}{\text{Overturning Moment}} = \frac{c_u L_a R}{W \cdot d} = \frac{c_u (R \theta) R}{W \cdot d} FS = Overturning Moment Resisting Moment = W ⋅ d c u L a R = W ⋅ d c u ( Rθ ) R Where L a = R θ L_a = R \theta L a = Rθ is the circular arc length, R R R is radius of the slip circle, W W W is total weight of sliding mass, and d d d is horizontal distance from circle center to mass centroid.
Ordinary Method of Slices (Fellenius): The sliding soil mass is subdivided into vertical slices. Assumes interslice forces are zero or equal and opposite: F S = ∑ [ c ′ Δ l + ( W i cos α i − u i Δ l ) tan ϕ ′ ] ∑ W i sin α i FS = \frac{\sum [ c' \Delta l + (W_i \cos \alpha_i - u_i \Delta l) \tan \phi' ]}{\sum W_i \sin \alpha_i} FS = ∑ W i s i n α i ∑ [ c ′ Δ l + ( W i c o s α i − u i Δ l ) t a n ϕ ′ ]
Bishop's Simplified Method: Considers normal interslice forces while assuming interslice shear forces are zero. Solved iteratively: F S = ∑ c ′ b i + ( W i − u i b i ) tan ϕ ′ m α ∑ W i sin α i , m α = cos α i ( 1 + tan α i tan ϕ ′ F S ) FS = \frac{\sum \frac{c' b_i + (W_i - u_i b_i) \tan \phi'}{m_\alpha}}{\sum W_i \sin \alpha_i}, \quad m_\alpha = \cos \alpha_i \left( 1 + \frac{\tan \alpha_i \tan \phi'}{FS} \right) FS = ∑ W i s i n α i ∑ m α c ′ b i + ( W i − u i b i ) t a n ϕ ′ , m α = cos α i ( 1 + FS t a n α i t a n ϕ ′ ) Bishop's method is standard practice, typically providing 5 % to 15 % 5\% \text{ to } 15\% 5% to 15% higher and more realistic factors of safety than Fellenius.
- Step-by-Step Worked Problem Examples
- Worked Example: Square Footing with Shallow Water Table
Problem: A reinforced concrete square column footing B × B = 2.0 m × 2.0 m B \times B = 2.0\text{ m} \times 2.0\text{ m} B × B = 2.0 m × 2.0 m is founded at depth D f = 1.5 m D_f = 1.5\text{ m} D f = 1.5 m below the ground surface. Soil properties are: moist unit weight γ moist = 18.5 kN/m 3 \gamma_{\text{moist}} = 18.5\text{ kN/m}^3 γ moist = 18.5 kN/m 3 , saturated unit weight γ sat = 20.0 kN/m 3 \gamma_{\text{sat}} = 20.0\text{ kN/m}^3 γ sat = 20.0 kN/m 3 (giving γ ′ = 20.0 − 9.81 = 10.19 kN/m 3 \gamma' = 20.0 - 9.81 = 10.19\text{ kN/m}^3 γ ′ = 20.0 − 9.81 = 10.19 kN/m 3 ), cohesion c = 20.0 kPa c = 20.0\text{ kPa} c = 20.0 kPa , and ϕ = 25 ∘ \phi = 25^\circ ϕ = 2 5 ∘ . Terzaghi bearing capacity factors for ϕ = 25 ∘ \phi = 25^\circ ϕ = 2 5 ∘ are N c = 25.1 N_c = 25.1 N c = 25.1 , N q = 12.7 N_q = 12.7 N q = 12.7 , N γ = 9.7 N_\gamma = 9.7 N γ = 9.7 . The groundwater table is located at depth d w = 2.5 m d_w = 2.5\text{ m} d w = 2.5 m below the ground surface. Utilizing a factor of safety of F S = 3.0 FS = 3.0 FS = 3.0 :
Compute the modified effective unit weight γ ˉ \bar{\gamma} γ ˉ for the soil wedge below the base.
Determine the ultimate bearing capacity q ult q_{\text{ult}} q ult .
Calculate the maximum allowable column load P all P_{\text{all}} P all .
Solution:
Step 1: Water Table Position Analysis D f = 1.5 m , d w = 2.5 m , D f + B = 1.5 + 2.0 = 3.5 m D_f = 1.5\text{ m}, \quad d_w = 2.5\text{ m}, \quad D_f + B = 1.5 + 2.0 = 3.5\text{ m} D f = 1.5 m , d w = 2.5 m , D f + B = 1.5 + 2.0 = 3.5 m Since D f < d w ≤ D f + B D_f < d_w \le D_f + B D f < d w ≤ D f + B ( 1.5 < 2.5 ≤ 3.5 m 1.5 < 2.5 \le 3.5\text{ m} 1.5 < 2.5 ≤ 3.5 m ), this is Case 2 : the water table lies within the failure wedge depth B B B below the base.
Surcharge q q q (above footing base) is entirely dry/moist: q = γ moist D f = 18.5 kN/m 3 × 1.5 m = 27.75 kPa q = \gamma_{\text{moist}} D_f = 18.5\text{ kN/m}^3 \times 1.5\text{ m} = 27.75\text{ kPa} q = γ moist D f = 18.5 kN/m 3 × 1.5 m = 27.75 kPa
Effective unit weight γ ˉ \bar{\gamma} γ ˉ for the third term is weighted over depth B B B : γ ˉ = γ ′ + ( d w − D f B ) ( γ moist − γ ′ ) \bar{\gamma} = \gamma' + \left( \frac{d_w - D_f}{B} \right) (\gamma_{\text{moist}} - \gamma') γ ˉ = γ ′ + ( B d w − D f ) ( γ moist − γ ′ ) γ ˉ = 10.19 + ( 2.5 − 1.5 2.0 ) ( 18.5 − 10.19 ) = 10.19 + ( 0.50 ) ( 8.31 ) = 10.19 + 4.155 = 14.345 kN/m 3 \bar{\gamma} = 10.19 + \left( \frac{2.5 - 1.5}{2.0} \right) (18.5 - 10.19) = 10.19 + (0.50)(8.31) = 10.19 + 4.155 = 14.345\text{ kN/m}^3 γ ˉ = 10.19 + ( 2.0 2.5 − 1.5 ) ( 18.5 − 10.19 ) = 10.19 + ( 0.50 ) ( 8.31 ) = 10.19 + 4.155 = 14.345 kN/m 3
Step 2: Calculate Ultimate Bearing Capacity ( q ult q_{\text{ult}} q ult ) Using Terzaghi's square footing equation: q ult = 1.3 c N c + q N q + 0.4 γ ˉ B N γ q_{\text{ult}} = 1.3 c N_c + q N_q + 0.4 \bar{\gamma} B N_\gamma q ult = 1.3 c N c + q N q + 0.4 γ ˉ B N γ Evaluate each term:
Cohesion term: 1.3 × 20.0 × 25.1 = 652.60 kPa 1.3 \times 20.0 \times 25.1 = 652.60\text{ kPa} 1.3 × 20.0 × 25.1 = 652.60 kPa
Surcharge term: 27.75 × 12.7 = 352.43 kPa 27.75 \times 12.7 = 352.43\text{ kPa} 27.75 × 12.7 = 352.43 kPa
Soil wedge term: 0.4 × 14.345 × 2.0 × 9.7 = 111.32 kPa 0.4 \times 14.345 \times 2.0 \times 9.7 = 111.32\text{ kPa} 0.4 × 14.345 × 2.0 × 9.7 = 111.32 kPa q ult = 652.60 + 352.43 + 111.32 = 1 , 116.35 kPa ≈ 1 , 116.4 kPa q_{\text{ult}} = 652.60 + 352.43 + 111.32 = 1,116.35\text{ kPa} \approx 1,116.4\text{ kPa} q ult = 652.60 + 352.43 + 111.32 = 1 , 116.35 kPa ≈ 1 , 116.4 kPa
Step 3: Calculate Allowable Column Load ( P all P_{\text{all}} P all ) q all = q ult F S = 1 , 116.35 3.0 = 372.12 kPa q_{\text{all}} = \frac{q_{\text{ult}}}{FS} = \frac{1,116.35}{3.0} = 372.12\text{ kPa} q all = FS q ult = 3.0 1 , 116.35 = 372.12 kPa P all = q all × B 2 = 372.12 kPa × ( 2.0 m ) 2 = 372.12 × 4.0 = 1 , 488.48 kN ≈ 1 , 488.5 kN P_{\text{all}} = q_{\text{all}} \times B^2 = 372.12\text{ kPa} \times (2.0\text{ m})^2 = 372.12 \times 4.0 = 1,488.48\text{ kN} \approx 1,488.5\text{ kN} P all = q all × B 2 = 372.12 kPa × ( 2.0 m ) 2 = 372.12 × 4.0 = 1 , 488.48 kN ≈ 1 , 488.5 kN
CELE Board Exam Traps & Strategic Checklists
Warning
Footing Shape Factor Mix-Up: Pay close attention to the third term coefficient in Terzaghi's equation. Strip footings use 0.5 γ B N γ 0.5 \gamma B N_\gamma 0.5 γ B N γ ; square footings use 0.4 γ B N γ 0.4 \gamma B N_\gamma 0.4 γ B N γ ; circular footings use 0.3 γ B N γ 0.3 \gamma B N_\gamma 0.3 γ B N γ . Confusing 0.4 0.4 0.4 and 0.5 0.5 0.5 is one of the most common point losses on the CELE.
Clay Bearing Capacity Trap ( ϕ = 0 ∘ \phi = 0^\circ ϕ = 0 ∘ ): For saturated clay, N c = 5.7 N_c = 5.7 N c = 5.7 , N q = 1.0 N_q = 1.0 N q = 1.0 , and N γ = 0 N_\gamma = 0 N γ = 0 . For a square footing, q ult = 1.3 ( 5.7 ) c u + q = 7.41 c u + q q_{\text{ult}} = 1.3(5.7)c_u + q = 7.41 c_u + q q ult = 1.3 ( 5.7 ) c u + q = 7.41 c u + q . Examinees often forget the 1.3 1.3 1.3 shape multiplier or mistakenly add a third term.
Pile Block Failure Check: Never assume individual pile capacity governs group capacity. In soft sensitive clays with close pile spacing ( s < 3 D s < 3D s < 3 D ), block failure almost always governs. You must evaluate both ∑ Q single \sum Q_{\text{single}} ∑ Q single and Q block Q_{\text{block}} Q block .