8.2 Flow Measurement: Orifices, Weirs, and Venturi Meters

PRC Civil Engineer Licensure Examination CELE

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Examination Overview, RA 544 & Professional Practice

1.1 CELE Structure, Format, Scoring, and 2026 Subject Order 1.2 Republic Act No. 544: The Civil Engineering Law and Board Regulations 1.3 Civil Engineering Ethics, Contracts, and Professional Practice

2 Chapter 2: Engineering Mathematics, Numerical Methods & Physics

2.1 Advanced Algebra, Progressions & Word Problems 2.2 Trigonometry and Analytical Geometry 2.3 Differential and Integral Calculus 2.4 Differential Equations and Numerical Methods 2.5 Series, Hyperbolic Functions, Multivariable Calculus, and Laplace Transforms 2.6 Numerical Methods: Linear Systems, Interpolation, Curve Fitting, and ODE Solvers 2.7 Physics for Engineers: Kinematics, Newton's Laws, Work-Energy, and Momentum

3 Chapter 3: Engineering Data Analysis & Engineering Economy

3.1 Engineering Data Analysis and Statistical Applications 3.2 Parameter Estimation, Linear Regression, Correlation, and Queuing Models 3.3 Engineering Economy: Time Value of Money and Interest Formulas 3.4 Project Evaluation, Depreciation, and Benefit-Cost Analysis

4 Chapter 4: Surveying Fundamentals, Construction Layout & Route Surveying

4.1 Errors, Corrections, and Pacing/Taping 4.2 Leveling, Earthworks, and Mass Haul Diagrams 4.3 Traverse Computations, Balancing, and Area Determinations 4.4 Route Surveying: Horizontal and Vertical Curves

5 Chapter 5: Highway & Transportation Engineering

5.1 Highway Geometric Design and Sight Distances 5.2 Traffic Engineering, Flow Fundamentals, and Pavement Design 5.3 Highway Policy, Route Location, Drainage, and Earthwork Slopes 5.4 Transportation Planning, Network Analysis, and Intermodal Systems

6 Chapter 6: Construction Materials, Methods, Management & Safety

6.1 Materials for Construction: Concrete, Formwork, Masonry, Steel, and Wood Products 6.2 Construction Equipment, Formwork, and Construction Methods 6.3 Construction Occupational Safety and Health: RA 11058 and DOLE DO 13 6.4 Construction Project Management, CPM/PERT, and Resource Scheduling 6.5 Construction Principles: Design Requirements, Project Organization, Cost Control, and Value Engineering 6.6 Quantity Surveying, Unit Cost Analysis, and Project Cost Estimates 6.7 Construction Trades and Specialties: Plumbing, Plastics, Doors and Windows, Finishes, and Electrical

7 Chapter 7: Fluid Properties, Hydrostatics & Buoyancy

7.1 Fluid Properties, Units, and Pressure Measurement 7.2 Hydrostatic Pressure on Plane and Curved Surfaces 7.3 Buoyancy, Flotation, and Accelerated Fluid Masses

8 Chapter 8: Hydrodynamics, Pipe Flow, Open Channels & Water Supply

8.1 Fluid Dynamics: Continuity and Energy Equations 8.2 Flow Measurement: Orifices, Weirs, and Venturi Meters 8.3 Fluid Flow in Pipes, Friction Losses, and Pipe Networks 8.4 Open Channel Flow, Manning's Equation, and Hydraulic Jump 8.5 Water Supply: Demand, Storage, Pumping, Distribution, and Treatment

9 Chapter 9: Soil Properties, Seepage & Stresses in Soil Mass

9.1 Soil Composition, Weight-Volume Phase Relationships 9.2 Soil Classification Systems (USCS & AASHTO) and Atterberg Limits 9.3 Soil Permeability, Seepage, Flow Nets, and Effective Stress 9.4 Stresses in Soil Mass, Stress Distribution, and Immediate and Secondary Settlement

10 Chapter 10: Consolidation, Soil Strength, Earth Pressures & Foundations

10.1 Soil Compaction and Soil Compressibility/Consolidation 10.2 Shear Strength of Soils and Mohr-Coulomb Failure Criteria 10.3 Lateral Earth Pressures (Rankine & Coulomb) and Retaining Walls 10.4 Shallow and Deep Foundation Bearing Capacity and Slope Stability

11 Chapter 11: Engineering Mechanics & Statics

11.1 Force Systems, Resultants, and Equilibrium of Rigid Bodies 11.2 Centroids, Moments of Inertia, and Friction 11.3 Cables, Trusses, and Internal Forces in Members

12 Chapter 12: Strength of Materials

12.1 Axial Stress, Strain, and Deformation 12.2 Torsion, Flanged Bolt Couplings, and Thin-Walled Pressure Vessels 12.3 Beam Stresses: Flexural and Transverse Shear 12.4 Beam Deflections, Combined Stresses, and Mohr's Circle

13 Chapter 13: Structural Analysis & NSCP Load Criteria

13.1 Indeterminate Structures: Approximate and Classical Methods 13.2 Moment Distribution Method and Slope Deflection 13.3 Influence Lines for Determinate and Indeterminate Structures 13.4 NSCP Minimum Design Loads: Dead, Live, Wind, and Earthquake

14 Chapter 14: Reinforced Concrete Design (NSCP 2015 / USD)

14.1 Ultimate Strength Design (USD) Principles and Singly Reinforced Beams 14.2 Doubly Reinforced Beams and T-Beams 14.3 Shear and Diagonal Tension, Stirrup Design, and Development Length 14.4 Reinforced Concrete Columns and Isolated Footing Design

15 Chapter 15: Steel, Timber & Prestressed Design and Materials Testing

15.1 Structural Steel Tension Members and Connections 15.2 Structural Steel Compression Members and Beam Design 15.3 Timber Design Principles, Working Stress, and Sawn Lumber Beams 15.4 Prestressed Concrete Fundamentals and Prestress Losses 15.5 Construction Materials Testing and Concrete Mix Proportioning

8.2 Flow Measurement: Orifices, Weirs, and Venturi Meters

Key Takeaways Explain This Topic AI

Torricelli's theorem governs ideal orifice efflux velocity v t = 2 g h v_t = \sqrt{2gh} v t ​ = 2 g h ​ , which is modified for real fluids through hydraulic coefficients: coefficient of velocity C v = v act / v t ≈ 0.97 – 0.99 C_v = v_{\text{act}}/v_t \approx 0.97\text{–}0.99 C v ​ = v act ​ / v t ​ ≈ 0.97 – 0.99 , coefficient of contraction C c = A jet / A o ≈ 0.62 – 0.64 C_c = A_{\text{jet}}/A_o \approx 0.62\text{–}0.64 C c ​ = A jet ​ / A o ​ ≈ 0.62 – 0.64 at the vena contracta, and coefficient of discharge C d = C v ⋅ C c ≈ 0.60 – 0.62 C_d = C_v \cdot C_c \approx 0.60\text{–}0.62 C d ​ = C v ​ ⋅ C c ​ ≈ 0.60 – 0.62 .

For fully submerged orifices, discharge is governed strictly by the differential head between the upstream and downstream pools ( h = Δ H h = \Delta H h = Δ H ), operating completely independent of the absolute depth of orifice submergence.

The time to lower the liquid level in a prismatic or cylindrical tank of cross-sectional area A s A_s A s ​ through an orifice is obtained by integrating continuity: t = 2 A s C d A o 2 g ( h 1 − h 2 ) t = \frac{2A_s}{C_d A_o \sqrt{2g}}(\sqrt{h_1} - \sqrt{h_2}) t = C d ​ A o ​ 2 g ​ 2 A s ​ ​ ( h 1 ​ ​ − h 2 ​ ​ ) , proving that draining a tank completely takes exactly twice the duration required to discharge the same volume under a constant initial head h 1 h_1 h 1 ​ .

A Venturi meter utilizes a converging inlet, throat, and gradual diffuser to measure closed-pipe discharge from differential piezometric head Δ H \Delta H Δ H with Q = C d A 1 A 2 A 1 2 − A 2 2 2 g Δ H Q = \frac{C_d A_1 A_2}{\sqrt{A_1^2 - A_2^2}} \sqrt{2g \Delta H} Q = A 1 2 ​ − A 2 2 ​ ​ C d ​ A 1 ​ A 2 ​ ​ 2 g Δ H ​ , achieving high discharge coefficients ( C d ≈ 0.96 – 0.99 C_d \approx 0.96\text{–}0.99 C d ​ ≈ 0.96 – 0.99 ) with minimal permanent head loss.

Open-channel discharge over weirs follows geometric formulas: Francis suppressed rectangular weir ( Q = 1.84 L H 3 / 2 Q = 1.84 L H^{3/2} Q = 1.84 L H 3/2 ), contracted rectangular weir ( Q = 1.84 ( L − 0.1 n H ) H 3 / 2 Q = 1.84 (L - 0.1 n H) H^{3/2} Q = 1.84 ( L − 0.1 n H ) H 3/2 ), 90° triangular V-notch weir ( Q = 1.40 H 2.5 Q = 1.40 H^{2.5} Q = 1.40 H 2.5 ), and Cipolletti trapezoidal weir ( Q = 1.859 L H 1.5 Q = 1.859 L H^{1.5} Q = 1.859 L H 1.5 ) where 1:4 side slopes compensate exactly for end contractions.

Last updated: October 2026

8.2 Flow Measurement: Orifices, Weirs, and Venturi Meters

Flow measurement is an indispensable core competency for civil engineers engaged in water resources, irrigation, municipal water supply, and stormwater management. In the CELE Hydraulics syllabus, measurement problems are divided into two operational regimes: closed conduit devices (orifices, Venturi meters, Pitot tubes, flow nozzles) and free-surface open channel structures (sharp-crested weirs, broad-crested weirs, flumes). Both categories originate from Bernoulli's principle and continuity, modified by empirical discharge coefficients that account for fluid viscosity and streamline contraction.

1. Flow Through Standard Orifices and Torricelli's Theorem

An orifice is an opening with a closed perimeter in the wall or bottom of a tank, vessel, or conduit through which fluid discharges under the influence of pressure head.

Torricelli's Theorem and the Vena Contracta

Applying Bernoulli's equation between the free liquid surface of a deep open tank (where v 1 ≈ 0 , P 1 = 0 v_1 \approx 0, P_1 = 0 v 1 ​ ≈ 0 , P 1 ​ = 0 ) and a discharging jet open to the atmosphere ( P 2 = 0 P_2 = 0 P 2 ​ = 0 ) located a vertical depth h h h below the surface yields Torricelli's Theorem for ideal efflux velocity: 0 + 0 + h = 0 + v t 2 2 g + 0 ⟹ v t = 2 g h 0 + 0 + h = 0 + \frac{v_t^2}{2g} + 0 \implies v_t = \sqrt{2gh} 0 + 0 + h = 0 + 2 g v t 2 ​ ​ + 0 ⟹ v t ​ = 2 g h ​ In a real sharp-edged circular orifice, fluid converging toward the opening cannot turn sharp 90 ∘ 90^\circ 9 0 ∘ corners instantaneously due to momentum. Consequently, the streamlines continue to converge downstream of the physical orifice plate, forming a minimum jet cross-sectional area called the vena contracta , located at a distance of approximately 0.5 D 0.5 D 0.5 D downstream from the orifice opening.

The Three Fundamental Hydraulic Coefficients

Coefficient of Velocity ( C v C_v C v ​ ): The ratio of the actual average jet velocity at the vena contracta to the ideal theoretical velocity: C v = v act v t = v act 2 g h ( Typical range: 0.97 ≤ C v ≤ 0.99 ) C_v = \frac{v_{\text{act}}}{v_t} = \frac{v_{\text{act}}}{\sqrt{2gh}} \quad (\text{Typical range: } 0.97 \le C_v \le 0.99) C v ​ = v t ​ v act ​ ​ = 2 g h ​ v act ​ ​ ( Typical range: 0.97 ≤ C v ​ ≤ 0.99 )

Coefficient of Contraction ( C c C_c C c ​ ): The ratio of the cross-sectional area of the jet at the vena contracta ( A jet A_{\text{jet}} A jet ​ ) to the gross geometric area of the orifice opening ( A o A_o A o ​ ): C c = A jet A o ( Typical range for sharp edge: 0.62 ≤ C c ≤ 0.64 ) C_c = \frac{A_{\text{jet}}}{A_o} \quad (\text{Typical range for sharp edge: } 0.62 \le C_c \le 0.64) C c ​ = A o ​ A jet ​ ​ ( Typical range for sharp edge: 0.62 ≤ C c ​ ≤ 0.64 )

Coefficient of Discharge ( C d C_d C d ​ ): The ratio of the actual volumetric discharge to the theoretical discharge: C d = Q act Q ideal = A jet v act A o v t = C c ⋅ C v C_d = \frac{Q_{\text{act}}}{Q_{\text{ideal}}} = \frac{A_{\text{jet}} v_{\text{act}}}{A_o v_t} = C_c \cdot C_v C d ​ = Q ideal ​ Q act ​ ​ = A o ​ v t ​ A jet ​ v act ​ ​ = C c ​ ⋅ C v ​ Q act = C d A o 2 g h ( Standard sharp-edged orifice: C d ≈ 0.60 to 0.62 ) Q_{\text{act}} = C_d A_o \sqrt{2gh} \quad (\text{Standard sharp-edged orifice: } C_d \approx 0.60\text{ to }0.62) Q act ​ = C d ​ A o ​ 2 g h ​ ( Standard sharp-edged orifice: C d ​ ≈ 0.60 to 0.62 )

Head Loss Across an Orifice

The kinetic energy lost due to fluid shear and turbulence at an orifice is expressed as: h L = v t 2 2 g − v act 2 2 g = ( 1 C v 2 − 1 ) v act 2 2 g h_L = \frac{v_t^2}{2g} - \frac{v_{\text{act}}^2}{2g} = \left(\frac{1}{C_v^2} - 1\right) \frac{v_{\text{act}}^2}{2g} h L ​ = 2 g v t 2 ​ ​ − 2 g v act 2 ​ ​ = ( C v 2 ​ 1 ​ − 1 ) 2 g v act 2 ​ ​

Trajectory of a Horizontal Jet

If an orifice discharges horizontally at height y y y above the ground, the trajectory coordinates ( x , y ) (x, y) ( x , y ) of the vena contracta are governed by projectile motion: x = v act t , y = 1 2 g t 2 ⟹ t = 2 y g x = v_{\text{act}} t, \quad y = \frac{1}{2} g t^2 \implies t = \sqrt{\frac{2y}{g}} x = v act ​ t , y = 2 1 ​ g t 2 ⟹ t = g 2 y ​ ​ v act = x 2 y / g = x g 2 y ⟹ C v = v act 2 g h = x 2 y h v_{\text{act}} = \frac{x}{\sqrt{2y/g}} = \frac{x\sqrt{g}}{\sqrt{2y}} \implies C_v = \frac{v_{\text{act}}}{\sqrt{2gh}} = \frac{x}{2\sqrt{y h}} v act ​ = 2 y / g ​ x ​ = 2 y ​ x g ​ ​ ⟹ C v ​ = 2 g h ​ v act ​ ​ = 2 y h ​ x ​

  • 2. Submerged and Large Vertical Orifices
  • Submerged Orifices

When the discharging jet issues entirely into a downstream liquid pool rather than the open atmosphere, the orifice is fully submerged . Applying Bernoulli's equation between the upstream and downstream liquid surfaces shows that the driving head is the differential surface elevation Δ H = H 1 − H 2 \Delta H = H_1 - H_2 Δ H = H 1 ​ − H 2 ​ : Q = C d A o 2 g Δ H Q = C_d A_o \sqrt{2g \Delta H} Q = C d ​ A o ​ 2 g Δ H ​

Note

Submerged orifice discharge depends strictly on Δ H \Delta H Δ H and is entirely independent of the absolute depth of submergence below either water surface.

Large Vertical Rectangular Orifices

When the vertical height of an orifice ( d d d ) is large relative to the head ( h < 2 d h < 2d h < 2 d ), the velocity varies significantly from the top edge (head h 1 h_1 h 1 ​ ) to the bottom edge (head h 2 h_2 h 2 ​ ). Integrating elemental strips of width b b b and height d h dh d h : d Q = C d ( b d h ) 2 g h ⟹ Q = 2 3 C d b 2 g ( h 2 3 / 2 − h 1 3 / 2 ) dQ = C_d (b \, dh) \sqrt{2gh} \implies Q = \frac{2}{3} C_d b \sqrt{2g} \left(h_2^{3/2} - h_1^{3/2}\right) d Q = C d ​ ( b d h ) 2 g h ​ ⟹ Q = 3 2 ​ C d ​ b 2 g ​ ( h 2 3/2 ​ − h 1 3/2 ​ )

3. Unsteady Orifice Flow: Time to Empty Tanks

When liquid discharges through an orifice without inflow, the liquid depth decreases over time. Equating the volume of fluid leaving the tank in time d t dt d t to the reduction in liquid storage: − A s d h = Q out d t = C d A o 2 g h d t ⟹ d t = − A s C d A o 2 g h − 1 / 2 d h - A_s \, dh = Q_{\text{out}} \, dt = C_d A_o \sqrt{2gh} \, dt \implies dt = - \frac{A_s}{C_d A_o \sqrt{2g}} h^{-1/2} \, dh − A s ​ d h = Q out ​ d t = C d ​ A o ​ 2 g h ​ d t ⟹ d t = − C d ​ A o ​ 2 g ​ A s ​ ​ h − 1/2 d h where A s = A s ( h ) A_s = A_s(h) A s ​ = A s ​ ( h ) is the horizontal cross-sectional surface area of the tank at depth h h h .

Prismatic or Cylindrical Tank ( A s = constant A_s = \text{constant} A s ​ = constant )

Integrating between initial head h 1 h_1 h 1 ​ and final head h 2 h_2 h 2 ​ : t = ∫ h 2 h 1 A s C d A o 2 g h − 1 / 2 d h = 2 A s C d A o 2 g ( h 1 − h 2 ) t = \int_{h_2}^{h_1} \frac{A_s}{C_d A_o \sqrt{2g}} h^{-1/2} \, dh = \frac{2 A_s}{C_d A_o \sqrt{2g}} \left(\sqrt{h_1} - \sqrt{h_2}\right) t = ∫ h 2 ​ h 1 ​ ​ C d ​ A o ​ 2 g ​ A s ​ ​ h − 1/2 d h = C d ​ A o ​ 2 g ​ 2 A s ​ ​ ( h 1 ​ ​ − h 2 ​ ​ ) For total drainage ( h 2 = 0 h_2 = 0 h 2 ​ = 0 ): t drain = 2 A s h 1 C d A o 2 g t_{\text{drain}} = \frac{2 A_s \sqrt{h_1}}{C_d A_o \sqrt{2g}} t drain ​ = C d ​ A o ​ 2 g ​ 2 A s ​ h 1 ​ ​ ​

Important

The Factor-of-Two Emptying Rule: The volume of liquid in the tank is V = A s h 1 V = A_s h_1 V = A s ​ h 1 ​ . Under a constant initial head h 1 h_1 h 1 ​ , the discharge rate is Q 0 = C d A o 2 g h 1 Q_0 = C_d A_o \sqrt{2g h_1} Q 0 ​ = C d ​ A o ​ 2 g h 1 ​ ​ , which would drain the volume in time t 0 = V Q 0 = A s h 1 C d A o 2 g h 1 = A s h 1 C d A o 2 g t_0 = \frac{V}{Q_0} = \frac{A_s h_1}{C_d A_o \sqrt{2g h_1}} = \frac{A_s \sqrt{h_1}}{C_d A_o \sqrt{2g}} t 0 ​ = Q 0 ​ V ​ = C d ​ A o ​ 2 g h 1 ​ ​ A s ​ h 1 ​ ​ = C d ​ A o ​ 2 g ​ A s ​ h 1 ​ ​ ​ . Comparing this with t drain t_{\text{drain}} t drain ​ shows that t drain = 2 t 0 t_{\text{drain}} = 2 t_0 t drain ​ = 2 t 0 ​ —a tank under falling head requires exactly twice as long to empty as it would under a sustained constant initial head.

  • 4. Closed Conduit Devices: Venturi Meter and Pitot Tube
  • The Pitot Tube

A Pitot tube consists of an open tube with a 90 ∘ 90^\circ 9 0 ∘ bend facing directly upstream. At the stagnation point at the tube opening, fluid velocity decelerates to zero ( v = 0 v = 0 v = 0 ), converting dynamic pressure into stagnation pressure head: h stag = h static + v 2 2 g h_{\text{stag}} = h_{\text{static}} + \frac{v^2}{2g} h stag ​ = h static ​ + 2 g v 2 ​ . v = 2 g ( h stag − h static ) = 2 g Δ h v = \sqrt{2g (h_{\text{stag}} - h_{\text{static}})} = \sqrt{2g \Delta h} v = 2 g ( h stag ​ − h static ​ ) ​ = 2 g Δ h ​ In a Pitot-static tube , static pressure holes are integrated circumferentially, and an empirical instrument coefficient C p ≈ 0.98 – 1.00 C_p \approx 0.98\text{–}1.00 C p ​ ≈ 0.98 – 1.00 accounts for geometry: v = C p 2 g Δ h v = C_p \sqrt{2g \Delta h} v = C p ​ 2 g Δ h ​ .

The Venturi Meter

A Venturi meter consists of a smooth converging section ( 21 ∘ 21^\circ 2 1 ∘ cone angle), a constricted cylindrical throat, and a gradual diverging expansion cone ( 5 ∘ to 7 ∘ 5^\circ\text{ to }7^\circ 5 ∘ to 7 ∘ ) designed to prevent flow separation.

Loading diagram...

Writing Bernoulli's equation and continuity between pipe inlet (1) and throat (2): P 1 γ + z 1 + v 1 2 2 g = P 2 γ + z 2 + v 2 2 2 g \frac{P_1}{\gamma} + z_1 + \frac{v_1^2}{2g} = \frac{P_2}{\gamma} + z_2 + \frac{v_2^2}{2g} γ P 1 ​ ​ + z 1 ​ + 2 g v 1 2 ​ ​ = γ P 2 ​ ​ + z 2 ​ + 2 g v 2 2 ​ ​ Letting differential piezometric head be Δ H = ( P 1 γ + z 1 ) − ( P 2 γ + z 2 ) \Delta H = \left(\frac{P_1}{\gamma} + z_1\right) - \left(\frac{P_2}{\gamma} + z_2\right) Δ H = ( γ P 1 ​ ​ + z 1 ​ ) − ( γ P 2 ​ ​ + z 2 ​ ) , and substituting v 1 = v 2 ( A 2 / A 1 ) v_1 = v_2 (A_2 / A_1) v 1 ​ = v 2 ​ ( A 2 ​ / A 1 ​ ) : v 2 = 2 g Δ H 1 − ( A 2 / A 1 ) 2 = A 1 A 1 2 − A 2 2 2 g Δ H v_2 = \sqrt{\frac{2g \Delta H}{1 - (A_2/A_1)^2}} = \frac{A_1}{\sqrt{A_1^2 - A_2^2}} \sqrt{2g \Delta H} v 2 ​ = 1 − ( A 2 ​ / A 1 ​ ) 2 2 g Δ H ​ ​ = A 1 2 ​ − A 2 2 ​ ​ A 1 ​ ​ 2 g Δ H ​ Q act = C d A 1 A 2 A 1 2 − A 2 2 2 g Δ H Q_{\text{act}} = C_d \frac{A_1 A_2}{\sqrt{A_1^2 - A_2^2}} \sqrt{2g \Delta H} Q act ​ = C d ​ A 1 2 ​ − A 2 2 ​ ​ A 1 ​ A 2 ​ ​ 2 g Δ H ​ where C d C_d C d ​ is the discharge coefficient ( 0.96 ≤ C d ≤ 0.99 0.96 \le C_d \le 0.99 0.96 ≤ C d ​ ≤ 0.99 ). When a differential manometer containing gage fluid of specific gravity S G m SG_m S G m ​ connects sections 1 and 2, reading deflection y y y : Δ H = y ( S G m S G f − 1 ) \Delta H = y \left(\frac{SG_m}{SG_f} - 1\right) Δ H = y ( S G f ​ S G m ​ ​ − 1 )

5. Open-Channel Flow Measurement: Weirs

A weir is an overflow structure placed across an open channel to measure discharge as a function of the measured head H H H above the weir crest.

Weir Type Geometric Configuration Standard Metric Discharge Equation Notes & Applications

Suppressed Rectangular Weir Crest length L L L equals channel width B B B ; no end contractions Q = 1.84 L H 3 / 2 Q = 1.84 L H^{3/2} Q = 1.84 L H 3/2 (Francis formula) Requires aerated nappe beneath crest. With approach velocity v a v_a v a ​ : Q = 1.84 L [ ( H + h a ) 3 / 2 − h a 3 / 2 ] Q = 1.84 L [(H + h_a)^{3/2} - h_a^{3/2}] Q = 1.84 L [( H + h a ​ ) 3/2 − h a 3/2 ​ ] , h a = v a 2 / ( 2 g ) h_a = v_a^2/(2g) h a ​ = v a 2 ​ / ( 2 g ) .

Contracted Rectangular Weir Crest length L < B L < B L < B ; nappe contracts at both ends ( n = 2 n=2 n = 2 ) or one end ( n = 1 n=1 n = 1 ) Q = 1.84 ( L − 0.1 n H ) H 3 / 2 Q = 1.84 (L - 0.1 n H) H^{3/2} Q = 1.84 ( L − 0.1 n H ) H 3/2 Each end contraction reduces effective crest length by 0.1 H 0.1 H 0.1 H .

Triangular V-Notch Weir Symmetrical V-notch with vertex angle θ \theta θ Q = 8 15 C d 2 g tan ⁡ ( θ 2 ) H 5 / 2 Q = \frac{8}{15} C_d \sqrt{2g} \tan\left(\frac{\theta}{2}\right) H^{5/2} Q = 15 8 ​ C d ​ 2 g ​ tan ( 2 θ ​ ) H 5/2 For standard 90 ∘ 90^\circ 9 0 ∘ notch ( θ = 90 ∘ , C d ≈ 0.58 \theta = 90^\circ, C_d \approx 0.58 θ = 9 0 ∘ , C d ​ ≈ 0.58 ): Q = 1.40 H 2.5 Q = 1.40 H^{2.5} Q = 1.40 H 2.5 . Highly accurate for low flows.

Cipolletti Trapezoidal Weir Trapezoidal notch with side slopes 1 H : 4 V 1\text{H}:4\text{V} 1 H : 4 V ( tan ⁡ β = 0.25 \tan \beta = 0.25 tan β = 0.25 ) Q = 1.859 L H 3 / 2 Q = 1.859 L H^{3/2} Q = 1.859 L H 3/2 The 1 : 4 1:4 1 : 4 triangular side slope increases flow just enough to offset the loss from end contractions.

Broad-Crested Weir Crest length in flow direction L crest > 2.5 H L_{\text{crest}} > 2.5 H L crest ​ > 2.5 H Q = 1.705 b H 3 / 2 Q = 1.705 b H^{3/2} Q = 1.705 b H 3/2 Critical flow depth y c = 2 3 H y_c = \frac{2}{3} H y c ​ = 3 2 ​ H occurs on the horizontal crest.

6. Worked Example: Venturi Meter with Differential Manometer

Problem Statement: A horizontal Venturi meter is installed in a 200 mm 200\text{ mm} 200 mm internal diameter municipal water pipeline ( D 1 = 0.200 m D_1 = 0.200\text{ m} D 1 ​ = 0.200 m ). The throat diameter is 100 mm 100\text{ mm} 100 mm ( D 2 = 0.100 m D_2 = 0.100\text{ m} D 2 ​ = 0.100 m ). A differential mercury manometer ( S G m = 13.6 SG_m = 13.6 S G m ​ = 13.6 ) connected across the piezometer taps indicates a mercury column deflection of y = 220 mm y = 220\text{ mm} y = 220 mm ( 0.220 m 0.220\text{ m} 0.220 m ). The water temperature is 20 ∘ C 20^\circ\text{C} 2 0 ∘ C ( S G w = 1.00 SG_w = 1.00 S G w ​ = 1.00 , γ w = 9.81 kN/m 3 \gamma_w = 9.81\text{ kN/m}^3 γ w ​ = 9.81 kN/m 3 ). If the meter coefficient of discharge is C d = 0.980 C_d = 0.980 C d ​ = 0.980 , calculate (a) the differential head in meters of water, (b) the actual discharge in liters per second, and (c) the throat velocity.

Step-by-Step Solution:

Compute differential piezometric head ( Δ H \Delta H Δ H ): Δ H = y ( S G m S G w − 1 ) = ( 0.220 m ) ( 13.6 − 1.0 ) = 0.220 × 12.6 = 2.772 m of water \Delta H = y \left(\frac{SG_m}{SG_w} - 1\right) = (0.220\text{ m})(13.6 - 1.0) = 0.220 \times 12.6 = 2.772\text{ m of water} Δ H = y ( S G w ​ S G m ​ ​ − 1 ) = ( 0.220 m ) ( 13.6 − 1.0 ) = 0.220 × 12.6 = 2.772 m of water

Calculate conduit and throat cross-sectional areas: A 1 = π D 1 2 4 = π ( 0.200 ) 2 4 = 0.031416 m 2 A_1 = \frac{\pi D_1^2}{4} = \frac{\pi (0.200)^2}{4} = 0.031416\text{ m}^2 A 1 ​ = 4 π D 1 2 ​ ​ = 4 π ( 0.200 ) 2 ​ = 0.031416 m 2 A 2 = π D 2 2 4 = π ( 0.100 ) 2 4 = 0.007854 m 2 A_2 = \frac{\pi D_2^2}{4} = \frac{\pi (0.100)^2}{4} = 0.007854\text{ m}^2 A 2 ​ = 4 π D 2 2 ​ ​ = 4 π ( 0.100 ) 2 ​ = 0.007854 m 2 Area Ratio: A 1 A 2 = ( 0.200 0.100 ) 2 = 4.0 ⟹ ( A 1 A 2 ) 2 = 16.0 \text{Area Ratio: } \frac{A_1}{A_2} = \left(\frac{0.200}{0.100}\right)^2 = 4.0 \implies \left(\frac{A_1}{A_2}\right)^2 = 16.0 Area Ratio: A 2 ​ A 1 ​ ​ = ( 0.100 0.200 ​ ) 2 = 4.0 ⟹ ( A 2 ​ A 1 ​ ​ ) 2 = 16.0

Compute actual discharge ( Q act Q_{\text{act}} Q act ​ ): Q ideal = A 2 1 − ( A 2 / A 1 ) 2 2 g Δ H = 0.007854 m 2 1 − ( 1 / 16 ) 2 ( 9.81 m/s 2 ) ( 2.772 m ) Q_{\text{ideal}} = \frac{A_2}{\sqrt{1 - (A_2/A_1)^2}} \sqrt{2g \Delta H} = \frac{0.007854\text{ m}^2}{\sqrt{1 - (1/16)}} \sqrt{2(9.81\text{ m/s}^2)(2.772\text{ m})} Q ideal ​ = 1 − ( A 2 ​ / A 1 ​ ) 2 ​ A 2 ​ ​ 2 g Δ H ​ = 1 − ( 1/16 ) ​ 0.007854 m 2 ​ 2 ( 9.81 m/s 2 ) ( 2.772 m ) ​ 2 g Δ H = 54.3866 = 7.3747 m/s \sqrt{2g \Delta H} = \sqrt{54.3866} = 7.3747\text{ m/s} 2 g Δ H ​ = 54.3866 ​ = 7.3747 m/s 1 1 − 1 / 16 = 1 15 / 16 = 4 15 = 1.0328 \frac{1}{\sqrt{1 - 1/16}} = \frac{1}{\sqrt{15/16}} = \frac{4}{\sqrt{15}} = 1.0328 1 − 1/16 ​ 1 ​ = 15/16 ​ 1 ​ = 15 ​ 4 ​ = 1.0328 Q ideal = 0.007854 × 1.0328 × 7.3747 = 0.05982 m 3 / s Q_{\text{ideal}} = 0.007854 \times 1.0328 \times 7.3747 = 0.05982\text{ m}^3/\text{s} Q ideal ​ = 0.007854 × 1.0328 × 7.3747 = 0.05982 m 3 / s Q act = C d Q ideal = 0.980 × 0.05982 m 3 / s = 0.05862 m 3 / s = 58.62 L/s Q_{\text{act}} = C_d Q_{\text{ideal}} = 0.980 \times 0.05982\text{ m}^3/\text{s} = 0.05862\text{ m}^3/\text{s} = 58.62\text{ L/s} Q act ​ = C d ​ Q ideal ​ = 0.980 × 0.05982 m 3 / s = 0.05862 m 3 / s = 58.62 L/s

Calculate throat velocity ( v 2 v_2 v 2 ​ ): v 2 = Q act A 2 = 0.05862 m 3 / s 0.007854 m 2 = 7.464 m/s v_2 = \frac{Q_{\text{act}}}{A_2} = \frac{0.05862\text{ m}^3/\text{s}}{0.007854\text{ m}^2} = 7.464\text{ m/s} v 2 ​ = A 2 ​ Q act ​ ​ = 0.007854 m 2 0.05862 m 3 / s ​ = 7.464 m/s

7. CELE Exam Traps & Common Computational Errors

Warning

Trap 1: End Contraction Count in the Francis Formula: In the contracted rectangular weir formula Q = 1.84 ( L − 0.1 n H ) H 3 / 2 Q = 1.84 (L - 0.1 n H) H^{3/2} Q = 1.84 ( L − 0.1 n H ) H 3/2 , examine the problem geometry carefully. For a channel where the weir plate contracts the nappe from both sidewalls, n = 2 n = 2 n = 2 , yielding effective length ( L − 0.2 H ) (L - 0.2H) ( L − 0.2 H ) . If one side is flush with the channel wall and only the other contracts, n = 1 n = 1 n = 1 . For a fully suppressed weir spanning the entire flume, n = 0 n = 0 n = 0 .

Warning

Trap 2: Weir Head Exponents (1.5 vs. 2.5): Rectangular and Cipolletti weirs possess discharge proportional to H 3 / 2 = H 1.5 H^{3/2} = H^{1.5} H 3/2 = H 1.5 . Triangular V-notch weirs possess discharge proportional to H 5 / 2 = H 2.5 H^{5/2} = H^{2.5} H 5/2 = H 2.5 . Using the wrong power is an instantaneous point deduction on board problems.

Warning

Trap 3: Vena Contracta Area vs. Gross Orifice Area: Do not use the gross opening area A o A_o A o ​ when calculating actual jet velocity from discharge: v act = Q act A jet = Q act C c A o v_{\text{act}} = \frac{Q_{\text{act}}}{A_{\text{jet}}} = \frac{Q_{\text{act}}}{C_c A_o} v act ​ = A jet ​ Q act ​ ​ = C c ​ A o ​ Q act ​ ​ . Using v act = Q / A o v_{\text{act}} = Q / A_o v act ​ = Q / A o ​ understates the true jet kinetic energy by a factor of C c ≈ 0.62 C_c \approx 0.62 C c ​ ≈ 0.62 .