Study guide
14.3 Shear and Diagonal Tension, Stirrup Design, and Development Length
PRC Civil Engineer Licensure Examination CELE
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Examination Overview, RA 544 & Professional Practice
1.1 CELE Structure, Format, Scoring, and 2026 Subject Order 1.2 Republic Act No. 544: The Civil Engineering Law and Board Regulations 1.3 Civil Engineering Ethics, Contracts, and Professional Practice
2 Chapter 2: Engineering Mathematics, Numerical Methods & Physics
2.1 Advanced Algebra, Progressions & Word Problems 2.2 Trigonometry and Analytical Geometry 2.3 Differential and Integral Calculus 2.4 Differential Equations and Numerical Methods 2.5 Series, Hyperbolic Functions, Multivariable Calculus, and Laplace Transforms 2.6 Numerical Methods: Linear Systems, Interpolation, Curve Fitting, and ODE Solvers 2.7 Physics for Engineers: Kinematics, Newton's Laws, Work-Energy, and Momentum
3 Chapter 3: Engineering Data Analysis & Engineering Economy
3.1 Engineering Data Analysis and Statistical Applications 3.2 Parameter Estimation, Linear Regression, Correlation, and Queuing Models 3.3 Engineering Economy: Time Value of Money and Interest Formulas 3.4 Project Evaluation, Depreciation, and Benefit-Cost Analysis
4 Chapter 4: Surveying Fundamentals, Construction Layout & Route Surveying
4.1 Errors, Corrections, and Pacing/Taping 4.2 Leveling, Earthworks, and Mass Haul Diagrams 4.3 Traverse Computations, Balancing, and Area Determinations 4.4 Route Surveying: Horizontal and Vertical Curves
5 Chapter 5: Highway & Transportation Engineering
5.1 Highway Geometric Design and Sight Distances 5.2 Traffic Engineering, Flow Fundamentals, and Pavement Design 5.3 Highway Policy, Route Location, Drainage, and Earthwork Slopes 5.4 Transportation Planning, Network Analysis, and Intermodal Systems
6 Chapter 6: Construction Materials, Methods, Management & Safety
6.1 Materials for Construction: Concrete, Formwork, Masonry, Steel, and Wood Products 6.2 Construction Equipment, Formwork, and Construction Methods 6.3 Construction Occupational Safety and Health: RA 11058 and DOLE DO 13 6.4 Construction Project Management, CPM/PERT, and Resource Scheduling 6.5 Construction Principles: Design Requirements, Project Organization, Cost Control, and Value Engineering 6.6 Quantity Surveying, Unit Cost Analysis, and Project Cost Estimates 6.7 Construction Trades and Specialties: Plumbing, Plastics, Doors and Windows, Finishes, and Electrical
7 Chapter 7: Fluid Properties, Hydrostatics & Buoyancy
7.1 Fluid Properties, Units, and Pressure Measurement 7.2 Hydrostatic Pressure on Plane and Curved Surfaces 7.3 Buoyancy, Flotation, and Accelerated Fluid Masses
8 Chapter 8: Hydrodynamics, Pipe Flow, Open Channels & Water Supply
8.1 Fluid Dynamics: Continuity and Energy Equations 8.2 Flow Measurement: Orifices, Weirs, and Venturi Meters 8.3 Fluid Flow in Pipes, Friction Losses, and Pipe Networks 8.4 Open Channel Flow, Manning's Equation, and Hydraulic Jump 8.5 Water Supply: Demand, Storage, Pumping, Distribution, and Treatment
9 Chapter 9: Soil Properties, Seepage & Stresses in Soil Mass
9.1 Soil Composition, Weight-Volume Phase Relationships 9.2 Soil Classification Systems (USCS & AASHTO) and Atterberg Limits 9.3 Soil Permeability, Seepage, Flow Nets, and Effective Stress 9.4 Stresses in Soil Mass, Stress Distribution, and Immediate and Secondary Settlement
10 Chapter 10: Consolidation, Soil Strength, Earth Pressures & Foundations
10.1 Soil Compaction and Soil Compressibility/Consolidation 10.2 Shear Strength of Soils and Mohr-Coulomb Failure Criteria 10.3 Lateral Earth Pressures (Rankine & Coulomb) and Retaining Walls 10.4 Shallow and Deep Foundation Bearing Capacity and Slope Stability
11 Chapter 11: Engineering Mechanics & Statics
11.1 Force Systems, Resultants, and Equilibrium of Rigid Bodies 11.2 Centroids, Moments of Inertia, and Friction 11.3 Cables, Trusses, and Internal Forces in Members
12 Chapter 12: Strength of Materials
12.1 Axial Stress, Strain, and Deformation 12.2 Torsion, Flanged Bolt Couplings, and Thin-Walled Pressure Vessels 12.3 Beam Stresses: Flexural and Transverse Shear 12.4 Beam Deflections, Combined Stresses, and Mohr's Circle
13 Chapter 13: Structural Analysis & NSCP Load Criteria
13.1 Indeterminate Structures: Approximate and Classical Methods 13.2 Moment Distribution Method and Slope Deflection 13.3 Influence Lines for Determinate and Indeterminate Structures 13.4 NSCP Minimum Design Loads: Dead, Live, Wind, and Earthquake
14 Chapter 14: Reinforced Concrete Design (NSCP 2015 / USD)
14.1 Ultimate Strength Design (USD) Principles and Singly Reinforced Beams 14.2 Doubly Reinforced Beams and T-Beams 14.3 Shear and Diagonal Tension, Stirrup Design, and Development Length 14.4 Reinforced Concrete Columns and Isolated Footing Design
15 Chapter 15: Steel, Timber & Prestressed Design and Materials Testing
15.1 Structural Steel Tension Members and Connections 15.2 Structural Steel Compression Members and Beam Design 15.3 Timber Design Principles, Working Stress, and Sawn Lumber Beams 15.4 Prestressed Concrete Fundamentals and Prestress Losses 15.5 Construction Materials Testing and Concrete Mix Proportioning
14.3 Shear and Diagonal Tension, Stirrup Design, and Development Length
Key Takeaways Explain This Topic AI
Shear failure in reinforced concrete is brittle and catastrophic; under NSCP 2015, the critical section for transverse shear is evaluated at distance d d d from the face of the support when compressive bearing reaction exists.
The nominal shear strength is provided by concrete and transverse reinforcement: V n = V c + V s V_n = V_c + V_s V n = V c + V s , with factored requirement ϕ V n ≥ V u \phi V_n \ge V_u ϕ V n ≥ V u where the strength reduction factor for shear is ϕ = 0.75 \phi = 0.75 ϕ = 0.75 .
Concrete shear capacity is V c = 0.17 λ f c ′ b w d V_c = 0.17 \lambda \sqrt{f'_c} b_w d V c = 0.17 λ f c ′ b w d ; the stirrup contribution V s = A v f y t d s V_s = \frac{A_v f_{yt} d}{s} V s = s A v f y t d is capped at 0.66 f c ′ b w d 0.66 \sqrt{f'_c} b_w d 0.66 f c ′ b w d to prevent premature diagonal compression crushing of the concrete web.
Stirrup spacing limits depend on V s V_s V s : when V s ≤ 0.33 f c ′ b w d V_s \le 0.33 \sqrt{f'_c} b_w d V s ≤ 0.33 f c ′ b w d , s max = min ( d / 2 , 600 mm ) s_{\max} = \min(d/2, 600\text{ mm}) s m a x = min ( d /2 , 600 mm ) ; when V s > 0.33 f c ′ b w d V_s > 0.33 \sqrt{f'_c} b_w d V s > 0.33 f c ′ b w d , maximum allowable spacing is halved to s max = min ( d / 4 , 300 mm ) s_{\max} = \min(d/4, 300\text{ mm}) s m a x = min ( d /4 , 300 mm ) .
Tension development length l d l_d l d ensures reinforcing bars reach yield strength without slip or bond splitting; top bars (having > 300 mm of fresh concrete cast beneath them) require a 1.3 multiplier ( ψ t = 1.3 \psi_t = 1.3 ψ t = 1.3 ) due to water bleeding and air void entrapment.
Last updated: October 2026
14.3 Shear and Diagonal Tension, Stirrup Design, and Development Length
Unlike flexural failures—which are preceded by ductile warnings of extensive cracking and excessive deflection—shear failures in reinforced concrete beams are typically sudden, brittle, and catastrophic. Shear stresses interact with flexural normal stresses to produce principal tensile stresses inclined at roughly 45 ∘ 45^\circ 4 5 ∘ to the longitudinal beam axis. Because plain concrete has low tensile capacity, web cracks propagate diagonally along the principal compression trajectories. To protect against diagonal tension failure , structural engineers design transverse reinforcement—typically vertical closed or U-shaped stirrups —and enforce strict development length criteria to anchor longitudinal bars.
1. Shear Behavior and Diagonal Tension Cracking
Consider an infinitesimal element in a beam web subjected to transverse shear stress τ \tau τ and bending normal stress σ \sigma σ . From Mohr's circle of stress, the principal tensile stress σ 1 \sigma_1 σ 1 is:
σ 1 = σ 2 + ( σ 2 ) 2 + τ 2 \sigma_1 = \frac{\sigma}{2} + \sqrt{\left(\frac{\sigma}{2}\right)^2 + \tau^2} σ 1 = 2 σ + ( 2 σ ) 2 + τ 2
Near mid-span where bending moment is high and shear is low, σ \sigma σ dominates, producing nearly vertical flexural cracks .
Near supports where shear is high and bending moment is low (near the neutral axis where σ ≈ 0 \sigma \approx 0 σ ≈ 0 ), σ 1 ≈ τ \sigma_1 \approx \tau σ 1 ≈ τ acts at 45 ∘ 45^\circ 4 5 ∘ . Once σ 1 \sigma_1 σ 1 exceeds the tensile splitting strength of concrete ( f c t ≈ 0.33 f c ′ to 0.62 f c ′ MPa f_{ct} \approx 0.33\sqrt{f'_c}\text{ to } 0.62\sqrt{f'_c}\text{ MPa} f c t ≈ 0.33 f c ′ to 0.62 f c ′ MPa ), an inclined web-shear crack opens suddenly.
Between supports and mid-span, existing flexural cracks bend diagonally into the web, forming flexure-shear cracks .
2. Critical Section for Shear Design
Under NSCP 2015 Section 409.4.3.2, for beams supported by bearing reactions that introduce vertical compression into the end regions of the member (e.g., resting on top of columns or walls):
The maximum factored shear force V u V_u V u used for design is computed at a critical section located at a distance d d d from the face of the support .
All sections between the support face and distance d d d are designed for this same critical shear force V u V_u V u .
Important
The critical section at distance d d d is ONLY permitted when:
The support reaction introduces compressive stress into the end region of the member.
Loads are applied at or near the top surface of the beam.
No concentrated load acts between the support face and the distance d d d . If a concentrated load exists within distance d d d , or if the beam hangs in tension from a girder, the critical section must be taken directly at the face of the support .
3. Basic USD Shear Design Equations
Under NSCP 2015 Section 422.5, nominal shear strength V n V_n V n is the sum of the shear resisted by concrete ( V c V_c V c ) and the shear resisted by transverse reinforcement ( V s V_s V s ):
ϕ V n ≥ V u ⟹ ϕ ( V c + V s ) ≥ V u \phi V_n \ge V_u \implies \phi (V_c + V_s) \ge V_u ϕ V n ≥ V u ⟹ ϕ ( V c + V s ) ≥ V u
Where:
ϕ = 0.75 \phi = 0.75 ϕ = 0.75 is the strength reduction factor for shear and torsion.
Concrete Shear Strength ( V c V_c V c )
For members subjected to flexure and shear only (normal-weight concrete, λ = 1.0 \lambda = 1.0 λ = 1.0 ):
V c = 0.17 λ f c ′ b w d ( in N, with f c ′ in MPa and dimensions in mm ) V_c = 0.17 \lambda \sqrt{f'_c} b_w d \quad (\text{in N, with } f'_c \text{ in MPa and dimensions in mm}) V c = 0.17 λ f c ′ b w d ( in N, with f c ′ in MPa and dimensions in mm )
Where:
λ = 1.0 \lambda = 1.0 λ = 1.0 for normal-weight concrete.
λ = 0.85 \lambda = 0.85 λ = 0.85 for sand-lightweight concrete; λ = 0.75 \lambda = 0.75 λ = 0.75 for all-lightweight concrete.
b w b_w b w = web width of beam (mm).
d d d = effective depth to tension reinforcement (mm).
Required Stirrup Shear Strength ( V s V_s V s )
When factored shear V u V_u V u exceeds the design concrete capacity ϕ V c \phi V_c ϕ V c :
V s ≥ V u ϕ − V c = V u 0.75 − V c V_s \ge \frac{V_u}{\phi} - V_c = \frac{V_u}{0.75} - V_c V s ≥ ϕ V u − V c = 0.75 V u − V c
4. Stirrup Design Formulation
For vertical stirrups perpendicular to the longitudinal axis of the beam, the shear force resisted across a potential 45 ∘ 45^\circ 4 5 ∘ crack traversing ( d / s ) (d / s) ( d / s ) stirrups is:
V s = A v f y t d s V_s = \frac{A_v f_{yt} d}{s} V s = s A v f y t d
Solving for required stirrup spacing s s s :
s req = A v f y t d V s s_{\text{req}} = \frac{A_v f_{yt} d}{V_s} s req = V s A v f y t d
Where:
A v A_v A v = total cross-sectional area of all stirrup legs crossing the shear plane within spacing s s s . For a standard two-legged closed or U-stirrup, A v = 2 A b = 2 ( π d v 2 4 ) A_v = 2 A_b = 2 \left(\frac{\pi d_v^2}{4}\right) A v = 2 A b = 2 ( 4 π d v 2 ) .
f y t f_{yt} f y t = specified yield strength of transverse reinforcement (limited to f y t ≤ 420 MPa f_{yt} \le 420\text{ MPa} f y t ≤ 420 MPa for crack control per NSCP).
s s s = center-to-center longitudinal spacing of stirrups.
Upper Web Crushing Limit on V s V_s V s
To prevent catastrophic diagonal compression failure (crushing of the concrete web between diagonal tension cracks before stirrups reach yield), the code imposes a strict ceiling on stirrup resistance:
V s ≤ 0.66 f c ′ b w d V_s \le 0.66 \sqrt{f'_c} b_w d V s ≤ 0.66 f c ′ b w d
If V s > 0.66 f c ′ b w d V_s > 0.66 \sqrt{f'_c} b_w d V s > 0.66 f c ′ b w d , adding more stirrups is useless; the cross-section must be enlarged ( b w b_w b w or d d d increased) or concrete strength f c ′ f'_c f c ′ increased.
5. NSCP 2015 Stirrup Spacing Zones and Rules
NSCP 2015 Section 409.7.6.2.2 establishes four operational shear regimes:
Shear Demand Level Stirrup Requirement Maximum Allowable Spacing s max s_{\max} s m a x
Zone 1: V u ≤ 0.5 ϕ V c V_u \le 0.5 \phi V_c V u ≤ 0.5 ϕ V c No stirrups theoretically required by code None (stirrups optional)
Zone 2: 0.5 ϕ V c < V u ≤ ϕ V c 0.5 \phi V_c < V_u \le \phi V_c 0.5 ϕ V c < V u ≤ ϕ V c Minimum shear reinforcement mandatory s max = min ( d 2 , 600 mm ) s_{\max} = \min\left(\frac{d}{2}, \quad 600\text{ mm}\right) s m a x = min ( 2 d , 600 mm )
Zone 3: V u > ϕ V c V_u > \phi V_c V u > ϕ V c and V s ≤ 0.33 f c ′ b w d V_s \le 0.33 \sqrt{f'_c} b_w d V s ≤ 0.33 f c ′ b w d Design stirrups required: s = A v f y t d V s s = \frac{A_v f_{yt} d}{V_s} s = V s A v f y t d s max = min ( d 2 , 600 mm , s req ) s_{\max} = \min\left(\frac{d}{2}, \quad 600\text{ mm}, \quad s_{\text{req}}\right) s m a x = min ( 2 d , 600 mm , s req )
Zone 4: 0.33 f c ′ b w d < V s ≤ 0.66 f c ′ b w d 0.33 \sqrt{f'_c} b_w d < V_s \le 0.66 \sqrt{f'_c} b_w d 0.33 f c ′ b w d < V s ≤ 0.66 f c ′ b w d Heavy shear reinforcement; spacing halved s max = min ( d 4 , 300 mm , s req ) s_{\max} = \min\left(\frac{d}{4}, \quad 300\text{ mm}, \quad s_{\text{req}}\right) s m a x = min ( 4 d , 300 mm , s req )
Minimum Area of Shear Reinforcement ( A v , min A_{v,\min} A v , m i n )
In Zones 2 and 3, when stirrups are provided, the minimum area must satisfy:
A v , min = 0.062 f c ′ b w s f y t ≥ 0.35 b w s f y t A_{v,\min} = 0.062 \sqrt{f'_c} \frac{b_w s}{f_{yt}} \ge \frac{0.35 b_w s}{f_{yt}} A v , m i n = 0.062 f c ′ f y t b w s ≥ f y t 0.35 b w s
⟹ s max ≤ A v f y t 0.35 b w and s max ≤ A v f y t 0.062 f c ′ b w \implies s_{\max} \le \frac{A_v f_{yt}}{0.35 b_w} \quad \text{and} \quad s_{\max} \le \frac{A_v f_{yt}}{0.062 \sqrt{f'_c} b_w} ⟹ s m a x ≤ 0.35 b w A v f y t and s m a x ≤ 0.062 f c ′ b w A v f y t
6. Torsion Design of Beams (ACI 318-14 / NSCP 2015)
The PSAD TOS asks for design of "flexural, shear and torsion reinforcements." Torsion in beams usually comes from spandrel beams supporting slabs on one side, or from eccentric loads.
Section properties.
A c p A_{cp} A c p and p c p p_{cp} p c p are the area and perimeter of the outer concrete outline.
A o h A_{oh} A o h and p h p_h p h are the area and perimeter enclosed by the centerline of the outermost closed stirrup.
A o = 0.85 A o h A_o = 0.85 A_{oh} A o = 0.85 A o h .
When torsion can be neglected. For non-prestressed members, the threshold torsion is:
T t h = 0.083 λ f c ′ ( A c p 2 p c p ) T_{th} = 0.083 \lambda \sqrt{f'_c} \left( \frac{A_{cp}^2}{p_{cp}} \right) T t h = 0.083 λ f c ′ ( p c p A c p 2 )
Torsion may be neglected if T u < ϕ T t h T_u < \phi T_{th} T u < ϕ T t h , with ϕ = 0.75 \phi = 0.75 ϕ = 0.75 . Above that value, closed stirrups and longitudinal bars must resist the full torsion.
Equilibrium versus compatibility torsion. If the torsion is needed for equilibrium (a canopy beam), design for the full T u T_u T u . If it arises only from compatibility (a spandrel beam restrained by a slab), T u T_u T u may be reduced to the cracking torque, ϕ T c r = ϕ ( 0.33 λ f c ′ A c p 2 / p c p ) \phi T_{cr} = \phi(0.33 \lambda \sqrt{f'_c}\, A_{cp}^2 / p_{cp}) ϕ T cr = ϕ ( 0.33 λ f c ′ A c p 2 / p c p ) , and the moments redistributed.
Transverse reinforcement (one leg of a closed stirrup), with θ = 45 ∘ \theta = 45^\circ θ = 4 5 ∘ for non-prestressed members:
A t s = T u ϕ 2 A o f y t cot θ \frac{A_t}{s} = \frac{T_u}{\phi\, 2 A_o f_{yt} \cot\theta} s A t = ϕ 2 A o f y t c o t θ T u
Longitudinal reinforcement:
A ℓ = A t s p h ( f y t f y ) cot 2 θ A_\ell = \frac{A_t}{s}\, p_h \left( \frac{f_{yt}}{f_y} \right) \cot^2\theta A ℓ = s A t p h ( f y f y t ) cot 2 θ
Detailing rules:
Combine with shear stirrups as ( A v + 2 A t ) / s (A_v + 2A_t)/s ( A v + 2 A t ) / s , at least max ( 0.062 f c ′ , 0.35 ) b w / f y t \max(0.062\sqrt{f'_c},\; 0.35)\, b_w / f_{yt} max ( 0.062 f c ′ , 0.35 ) b w / f y t .
Torsion stirrup spacing must not exceed the smaller of p h / 8 p_h/8 p h /8 and 300 mm 300\text{ mm} 300 mm .
Longitudinal bars are distributed around the perimeter at no more than 300 mm 300\text{ mm} 300 mm , with a bar in each corner.
Example. A 300 × 500 mm 300 \times 500\text{ mm} 300 × 500 mm beam has f c ′ = 28 MPa f'_c = 28\text{ MPa} f c ′ = 28 MPa : A c p = 150,000 mm 2 A_{cp} = 150{,}000\text{ mm}^2 A c p = 150 , 000 mm 2 and p c p = 1,600 mm p_{cp} = 1{,}600\text{ mm} p c p = 1 , 600 mm . Then T t h = 0.083 ( 5.2915 ) ( 150,000 2 / 1,600 ) = 6.18 kN ⋅ m T_{th} = 0.083(5.2915)(150{,}000^2/1{,}600) = 6.18\text{ kN}\cdot\text{m} T t h = 0.083 ( 5.2915 ) ( 150 , 00 0 2 /1 , 600 ) = 6.18 kN ⋅ m and ϕ T t h = 4.63 kN ⋅ m \phi T_{th} = 4.63\text{ kN}\cdot\text{m} ϕ T t h = 4.63 kN ⋅ m . A factored torsion of 10 kN ⋅ m 10\text{ kN}\cdot\text{m} 10 kN ⋅ m therefore needs torsion reinforcement.
7. Development Length ( l d l_d l d ) of Deformed Bars in Tension
For reinforcing bars to develop their design yield strength f y f_y f y through flexure, they must be embedded into concrete by a sufficient length called the development length ( l d l_d l d ) . Bond transfer occurs via mechanical bearing of rebar deformations (ribs) against surrounding concrete, chemical adhesion, and frictional resistance.
General Code Equation (NSCP 2015 Section 425.4.2)
l d = [ f y 1.1 λ f c ′ ψ t ψ e ψ s ( c b + K t r d b ) ] d b ≥ 300 mm ( SI units: MPa, mm ) l_d = \left[\frac{f_y}{1.1 \lambda \sqrt{f'_c}} \frac{\psi_t \psi_e \psi_s}{\left(\frac{c_b + K_{tr}}{d_b}\right)}\right] d_b \ge 300\text{ mm} \quad (\text{SI units: MPa, mm}) l d = [ 1.1 λ f c ′ f y ( d b c b + K t r ) ψ t ψ e ψ s ] d b ≥ 300 mm ( SI units: MPa, mm )
Where the confinement term c b + K t r d b ≤ 2.5 \frac{c_b + K_{tr}}{d_b} \le 2.5 d b c b + K t r ≤ 2.5 .
Simplified Design Equations (NSCP 2015 Table 425.4.2.2)
For beams with clear spacing ≥ d b \ge d_b ≥ d b , clear cover ≥ d b \ge d_b ≥ d b , and stirrups meeting code minimums:
Bar Size Simplified Development Length l d l_d l d Formula
20 mm (No. 19) and smaller bars l d = ( f y ψ t ψ e 2.1 λ f c ′ ) d b ≥ 300 mm l_d = \left(\frac{f_y \psi_t \psi_e}{2.1 \lambda \sqrt{f'_c}}\right) d_b \ge 300\text{ mm} l d = ( 2.1 λ f c ′ f y ψ t ψ e ) d b ≥ 300 mm
22 mm (No. 22) and larger bars l d = ( f y ψ t ψ e 1.7 λ f c ′ ) d b ≥ 300 mm l_d = \left(\frac{f_y \psi_t \psi_e}{1.7 \lambda \sqrt{f'_c}}\right) d_b \ge 300\text{ mm} l d = ( 1.7 λ f c ′ f y ψ t ψ e ) d b ≥ 300 mm
Modification Factors:
ψ t \psi_t ψ t (Casting Position Factor):
ψ t = 1.3 \psi_t = 1.3 ψ t = 1.3 for top horizontal bars where more than 300 mm 300\text{ mm} 300 mm of fresh concrete is cast below the reinforcement. Bleed water and rising air bubbles settle beneath top bars, degrading bond strength.
ψ t = 1.0 \psi_t = 1.0 ψ t = 1.0 for other bars (bottom bars and vertical bars).
ψ e \psi_e ψ e (Coating Factor):
ψ e = 1.5 \psi_e = 1.5 ψ e = 1.5 for epoxy-coated bars with cover < 3 d b < 3 d_b < 3 d b or clear spacing < 6 d b < 6 d_b < 6 d b .
ψ e = 1.2 \psi_e = 1.2 ψ e = 1.2 for other epoxy-coated bars.
ψ e = 1.0 \psi_e = 1.0 ψ e = 1.0 for uncoated (black) bars.
(Note: The product ψ t ψ e \psi_t \psi_e ψ t ψ e need not exceed 1.7 1.7 1.7 .)
ψ s \psi_s ψ s (Size Factor): ψ s = 0.8 \psi_s = 0.8 ψ s = 0.8 for 20 mm (No. 19) and smaller bars; ψ s = 1.0 \psi_s = 1.0 ψ s = 1.0 for 22 mm and larger bars.
λ \lambda λ (Lightweight Factor): 1.0 1.0 1.0 for normal-weight; 0.75 0.75 0.75 for lightweight.
Standard Hooks in Tension ( l d h l_{dh} l d h )
When straight development length cannot be accommodated within member dimensions (e.g., at exterior beam-column joints), 90 ∘ 90^\circ 9 0 ∘ or 180 ∘ 180^\circ 18 0 ∘ standard hooks provide anchorage:
l d h = ( 0.24 f y ψ e λ f c ′ ) d b ≥ max ( 8 d b , 150 mm ) l_{dh} = \left(\frac{0.24 f_y \psi_e}{\lambda \sqrt{f'_c}}\right) d_b \ge \max(8 d_b, \quad 150\text{ mm}) l d h = ( λ f c ′ 0.24 f y ψ e ) d b ≥ max ( 8 d b , 150 mm )
- 8. Comprehensive Worked Examples
- Worked Example 1: Full Beam Stirrup Design
Problem: A simply supported rectangular beam spans L = 6.0 m L = 6.0\text{ m} L = 6.0 m between column supports ( 300 mm × 300 mm 300\text{ mm} \times 300\text{ mm} 300 mm × 300 mm columns). It supports a factored uniformly distributed load w u = 80 kN/m w_u = 80\text{ kN/m} w u = 80 kN/m (inclusive of self-weight). Beam cross-section: b w = 300 mm b_w = 300\text{ mm} b w = 300 mm , effective depth d = 500 mm d = 500\text{ mm} d = 500 mm . Materials: f c ′ = 28 MPa f'_c = 28\text{ MPa} f c ′ = 28 MPa , f y t = 280 MPa f_{yt} = 280\text{ MPa} f y t = 280 MPa (Grade 280 stirrups). Using 10 mm 10\text{ mm} 10 mm two-legged stirrups ( A v = 157.08 mm 2 A_v = 157.08\text{ mm}^2 A v = 157.08 mm 2 ):
(a) Determine the factored shear V u V_u V u at the critical section.
(b) Compute concrete shear capacity ϕ V c \phi V_c ϕ V c .
(c) Calculate the required stirrup spacing at the critical section and check all code limits.
Solution:
Step 1: Factored Shear at Critical Section: Centerline reaction: R = w u L 2 = 80 × 6.0 2 = 240.0 kN R = \frac{w_u L}{2} = \frac{80 \times 6.0}{2} = 240.0\text{ kN} R = 2 w u L = 2 80 × 6.0 = 240.0 kN .
Distance from support centerline to face of support: 0.30 2 = 0.15 m \frac{0.30}{2} = 0.15\text{ m} 2 0.30 = 0.15 m .
Critical section is at distance d = 500 mm = 0.50 m d = 500\text{ mm} = 0.50\text{ m} d = 500 mm = 0.50 m from face of support: x crit = 0.15 + 0.50 = 0.65 m x_{\text{crit}} = 0.15 + 0.50 = 0.65\text{ m} x crit = 0.15 + 0.50 = 0.65 m V u = R − w u x crit = 240.0 − 80 ( 0.65 ) = 240.0 − 52.0 = 188.0 kN V_u = R - w_u x_{\text{crit}} = 240.0 - 80(0.65) = 240.0 - 52.0 = 188.0\text{ kN} V u = R − w u x crit = 240.0 − 80 ( 0.65 ) = 240.0 − 52.0 = 188.0 kN
Step 2: Concrete Shear Strength: V c = 0.17 λ f c ′ b w d = 0.17 ( 1.0 ) 28 × 300 × 500 × 10 − 3 = 134.93 kN V_c = 0.17 \lambda \sqrt{f'_c} b_w d = 0.17(1.0)\sqrt{28} \times 300 \times 500 \times 10^{-3} = 134.93\text{ kN} V c = 0.17 λ f c ′ b w d = 0.17 ( 1.0 ) 28 × 300 × 500 × 1 0 − 3 = 134.93 kN ϕ V c = 0.75 × 134.93 = 101.20 kN \phi V_c = 0.75 \times 134.93 = 101.20\text{ kN} ϕ V c = 0.75 × 134.93 = 101.20 kN 0.5 ϕ V c = 0.5 × 101.20 = 50.60 kN 0.5 \phi V_c = 0.5 \times 101.20 = 50.60\text{ kN} 0.5 ϕ V c = 0.5 × 101.20 = 50.60 kN Since V u = 188.0 kN > ϕ V c = 101.20 kN V_u = 188.0\text{ kN} > \phi V_c = 101.20\text{ kN} V u = 188.0 kN > ϕ V c = 101.20 kN , web shear reinforcement is required.
Step 3: Required Stirrup Resistance ( V s V_s V s ): V s = V u ϕ − V c = 188.0 0.75 − 134.93 = 250.67 − 134.93 = 115.74 kN V_s = \frac{V_u}{\phi} - V_c = \frac{188.0}{0.75} - 134.93 = 250.67 - 134.93 = 115.74\text{ kN} V s = ϕ V u − V c = 0.75 188.0 − 134.93 = 250.67 − 134.93 = 115.74 kN
Check Upper Web Crushing Limit: V s , max = 0.66 f c ′ b w d = 0.66 28 × 300 × 500 × 10 − 3 = 523.85 kN V_{s,\max} = 0.66 \sqrt{f'_c} b_w d = 0.66 \sqrt{28} \times 300 \times 500 \times 10^{-3} = 523.85\text{ kN} V s , m a x = 0.66 f c ′ b w d = 0.66 28 × 300 × 500 × 1 0 − 3 = 523.85 kN Since V s = 115.74 kN ≪ 523.85 kN V_s = 115.74\text{ kN} \ll 523.85\text{ kN} V s = 115.74 kN ≪ 523.85 kN , web crushing is avoided.
Step 4: Determine Maximum Permissible Spacing ( s max s_{\max} s m a x ): Check threshold: 0.33 f c ′ b w d = 0.33 28 × 300 × 500 × 10 − 3 = 261.9 kN 0.33 \sqrt{f'_c} b_w d = 0.33 \sqrt{28} \times 300 \times 500 \times 10^{-3} = 261.9\text{ kN} 0.33 f c ′ b w d = 0.33 28 × 300 × 500 × 1 0 − 3 = 261.9 kN .
Since V s = 115.74 kN ≤ 261.9 kN V_s = 115.74\text{ kN} \le 261.9\text{ kN} V s = 115.74 kN ≤ 261.9 kN , the spacing is in Zone 3: s max = min ( d 2 , 600 mm ) = min ( 250 mm , 600 mm ) = 250 mm s_{\max} = \min\left(\frac{d}{2}, \quad 600\text{ mm}\right) = \min(250\text{ mm}, \quad 600\text{ mm}) = 250\text{ mm} s m a x = min ( 2 d , 600 mm ) = min ( 250 mm , 600 mm ) = 250 mm
Check Minimum Stirrup Area Spacing Limit: s ≤ A v f y t 0.35 b w = 157.08 × 280 0.35 × 300 = 43 , 982.4 105 = 418.9 mm s \le \frac{A_v f_{yt}}{0.35 b_w} = \frac{157.08 \times 280}{0.35 \times 300} = \frac{43,982.4}{105} = 418.9\text{ mm} s ≤ 0.35 b w A v f y t = 0.35 × 300 157.08 × 280 = 105 43 , 982.4 = 418.9 mm
Step 5: Theoretical Spacing at Critical Section: s req = A v f y t d V s = 157.08 × 280 × 500 115 , 740 = 21 , 991 , 200 115 , 740 = 189.99 mm s_{\text{req}} = \frac{A_v f_{yt} d}{V_s} = \frac{157.08 \times 280 \times 500}{115,740} = \frac{21,991,200}{115,740} = 189.99\text{ mm} s req = V s A v f y t d = 115 , 740 157.08 × 280 × 500 = 115 , 740 21 , 991 , 200 = 189.99 mm Selection: Provide 10 mm 10\text{ mm} 10 mm stirrups at s = 180 mm s = 180\text{ mm} s = 180 mm on centers (since 180 mm ≤ s req = 190 mm 180\text{ mm} \le s_{\text{req}} = 190\text{ mm} 180 mm ≤ s req = 190 mm and 180 mm ≤ s max = 250 mm 180\text{ mm} \le s_{\max} = 250\text{ mm} 180 mm ≤ s m a x = 250 mm ).
Worked Example 2: Tension Development Length of Top and Bottom Bars
Problem: A continuous beam has ϕ 25 mm \phi 25\text{ mm} ϕ 25 mm longitudinal bars ( d b = 25 mm d_b = 25\text{ mm} d b = 25 mm ) with f y = 420 MPa f_y = 420\text{ MPa} f y = 420 MPa and f c ′ = 28 MPa f'_c = 28\text{ MPa} f c ′ = 28 MPa in normal-weight concrete. The bars are uncoated (black) and satisfy code minimum cover and clear spacing. Calculate the required development length l d l_d l d for: (a) bottom bars, and (b) top negative moment bars having 400 mm 400\text{ mm} 400 mm of fresh concrete placed beneath them.
Solution:
For ϕ 25 mm \phi 25\text{ mm} ϕ 25 mm bars (22 mm and larger group), the simplified code equation is: l d = ( f y ψ t ψ e 1.7 λ f c ′ ) d b l_d = \left(\frac{f_y \psi_t \psi_e}{1.7 \lambda \sqrt{f'_c}}\right) d_b l d = ( 1.7 λ f c ′ f y ψ t ψ e ) d b
Material terms: λ = 1.0 \lambda = 1.0 λ = 1.0 , ψ e = 1.0 \psi_e = 1.0 ψ e = 1.0 , f c ′ = 28 = 5.2915 MPa \sqrt{f'_c} = \sqrt{28} = 5.2915\text{ MPa} f c ′ = 28 = 5.2915 MPa . f y 1.7 λ f c ′ = 420 1.7 × 1.0 × 5.2915 = 420 8.9956 = 46.689 \frac{f_y}{1.7 \lambda \sqrt{f'_c}} = \frac{420}{1.7 \times 1.0 \times 5.2915} = \frac{420}{8.9956} = 46.689 1.7 λ f c ′ f y = 1.7 × 1.0 × 5.2915 420 = 8.9956 420 = 46.689
(a) Bottom Bars: ψ t = 1.0 \psi_t = 1.0 ψ t = 1.0 : l d = 46.689 × 1.0 × 25 mm = 1167.2 mm ≈ 1170 mm l_d = 46.689 \times 1.0 \times 25\text{ mm} = 1167.2\text{ mm} \approx 1170\text{ mm} l d = 46.689 × 1.0 × 25 mm = 1167.2 mm ≈ 1170 mm
(b) Top Bars: Since > 300 mm > 300\text{ mm} > 300 mm of fresh concrete is cast beneath the bars, ψ t = 1.3 \psi_t = 1.3 ψ t = 1.3 : l d = 46.689 × 1.3 × 25 mm = 1517.4 mm ≈ 1520 mm l_d = 46.689 \times 1.3 \times 25\text{ mm} = 1517.4\text{ mm} \approx 1520\text{ mm} l d = 46.689 × 1.3 × 25 mm = 1517.4 mm ≈ 1520 mm (Top bars require a 30% longer embedment length!)
9. Licensure Exam Pitfalls & Review Notes
Warning
Pitfall 1: Stirrup Leg Area ( A v A_v A v ) In stirrup spacing formulas, A v A_v A v is the TOTAL area of all legs crossing the crack. For a standard closed loop or U-stirrup, A v = 2 A b A_v = 2 A_b A v = 2 A b . For a 4-legged stirrup, A v = 4 A b A_v = 4 A_b A v = 4 A b . Forgetting to multiply single bar area A b A_b A b by 2 results in halving the calculated spacing and doubling steel costs.
Caution
Pitfall 2: Maximum Spacing Halving Threshold When shear demand is high such that V s > 0.33 f c ′ b w d V_s > 0.33 \sqrt{f'_c} b_w d V s > 0.33 f c ′ b w d , maximum spacing drops from min ( d / 2 , 600 mm ) \min(d/2, 600\text{ mm}) min ( d /2 , 600 mm ) to min ( d / 4 , 300 mm ) \min(d/4, 300\text{ mm}) min ( d /4 , 300 mm ) . Candidates frequently remember d / 4 d/4 d /4 but forget the companion limit of 300 mm 300\text{ mm} 300 mm .
Tip
Pitfall 3: Top Bar Factor Application The casting position factor ψ t = 1.3 \psi_t = 1.3 ψ t = 1.3 applies ONLY when more than 300 mm 300\text{ mm} 300 mm of fresh concrete is cast beneath the bar. If a beam total depth is 350 mm 350\text{ mm} 350 mm with 50 mm 50\text{ mm} 50 mm top cover, the fresh concrete below the top bar is 300 mm 300\text{ mm} 300 mm (not > 300 mm > 300\text{ mm} > 300 mm ), so ψ t = 1.0 \psi_t = 1.0 ψ t = 1.0 .