Study guide
14.1 Ultimate Strength Design (USD) Principles and Singly Reinforced Beams
PRC Civil Engineer Licensure Examination CELE
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Examination Overview, RA 544 & Professional Practice
1.1 CELE Structure, Format, Scoring, and 2026 Subject Order 1.2 Republic Act No. 544: The Civil Engineering Law and Board Regulations 1.3 Civil Engineering Ethics, Contracts, and Professional Practice
2 Chapter 2: Engineering Mathematics, Numerical Methods & Physics
2.1 Advanced Algebra, Progressions & Word Problems 2.2 Trigonometry and Analytical Geometry 2.3 Differential and Integral Calculus 2.4 Differential Equations and Numerical Methods 2.5 Series, Hyperbolic Functions, Multivariable Calculus, and Laplace Transforms 2.6 Numerical Methods: Linear Systems, Interpolation, Curve Fitting, and ODE Solvers 2.7 Physics for Engineers: Kinematics, Newton's Laws, Work-Energy, and Momentum
3 Chapter 3: Engineering Data Analysis & Engineering Economy
3.1 Engineering Data Analysis and Statistical Applications 3.2 Parameter Estimation, Linear Regression, Correlation, and Queuing Models 3.3 Engineering Economy: Time Value of Money and Interest Formulas 3.4 Project Evaluation, Depreciation, and Benefit-Cost Analysis
4 Chapter 4: Surveying Fundamentals, Construction Layout & Route Surveying
4.1 Errors, Corrections, and Pacing/Taping 4.2 Leveling, Earthworks, and Mass Haul Diagrams 4.3 Traverse Computations, Balancing, and Area Determinations 4.4 Route Surveying: Horizontal and Vertical Curves
5 Chapter 5: Highway & Transportation Engineering
5.1 Highway Geometric Design and Sight Distances 5.2 Traffic Engineering, Flow Fundamentals, and Pavement Design 5.3 Highway Policy, Route Location, Drainage, and Earthwork Slopes 5.4 Transportation Planning, Network Analysis, and Intermodal Systems
6 Chapter 6: Construction Materials, Methods, Management & Safety
6.1 Materials for Construction: Concrete, Formwork, Masonry, Steel, and Wood Products 6.2 Construction Equipment, Formwork, and Construction Methods 6.3 Construction Occupational Safety and Health: RA 11058 and DOLE DO 13 6.4 Construction Project Management, CPM/PERT, and Resource Scheduling 6.5 Construction Principles: Design Requirements, Project Organization, Cost Control, and Value Engineering 6.6 Quantity Surveying, Unit Cost Analysis, and Project Cost Estimates 6.7 Construction Trades and Specialties: Plumbing, Plastics, Doors and Windows, Finishes, and Electrical
7 Chapter 7: Fluid Properties, Hydrostatics & Buoyancy
7.1 Fluid Properties, Units, and Pressure Measurement 7.2 Hydrostatic Pressure on Plane and Curved Surfaces 7.3 Buoyancy, Flotation, and Accelerated Fluid Masses
8 Chapter 8: Hydrodynamics, Pipe Flow, Open Channels & Water Supply
8.1 Fluid Dynamics: Continuity and Energy Equations 8.2 Flow Measurement: Orifices, Weirs, and Venturi Meters 8.3 Fluid Flow in Pipes, Friction Losses, and Pipe Networks 8.4 Open Channel Flow, Manning's Equation, and Hydraulic Jump 8.5 Water Supply: Demand, Storage, Pumping, Distribution, and Treatment
9 Chapter 9: Soil Properties, Seepage & Stresses in Soil Mass
9.1 Soil Composition, Weight-Volume Phase Relationships 9.2 Soil Classification Systems (USCS & AASHTO) and Atterberg Limits 9.3 Soil Permeability, Seepage, Flow Nets, and Effective Stress 9.4 Stresses in Soil Mass, Stress Distribution, and Immediate and Secondary Settlement
10 Chapter 10: Consolidation, Soil Strength, Earth Pressures & Foundations
10.1 Soil Compaction and Soil Compressibility/Consolidation 10.2 Shear Strength of Soils and Mohr-Coulomb Failure Criteria 10.3 Lateral Earth Pressures (Rankine & Coulomb) and Retaining Walls 10.4 Shallow and Deep Foundation Bearing Capacity and Slope Stability
11 Chapter 11: Engineering Mechanics & Statics
11.1 Force Systems, Resultants, and Equilibrium of Rigid Bodies 11.2 Centroids, Moments of Inertia, and Friction 11.3 Cables, Trusses, and Internal Forces in Members
12 Chapter 12: Strength of Materials
12.1 Axial Stress, Strain, and Deformation 12.2 Torsion, Flanged Bolt Couplings, and Thin-Walled Pressure Vessels 12.3 Beam Stresses: Flexural and Transverse Shear 12.4 Beam Deflections, Combined Stresses, and Mohr's Circle
13 Chapter 13: Structural Analysis & NSCP Load Criteria
13.1 Indeterminate Structures: Approximate and Classical Methods 13.2 Moment Distribution Method and Slope Deflection 13.3 Influence Lines for Determinate and Indeterminate Structures 13.4 NSCP Minimum Design Loads: Dead, Live, Wind, and Earthquake
14 Chapter 14: Reinforced Concrete Design (NSCP 2015 / USD)
14.1 Ultimate Strength Design (USD) Principles and Singly Reinforced Beams 14.2 Doubly Reinforced Beams and T-Beams 14.3 Shear and Diagonal Tension, Stirrup Design, and Development Length 14.4 Reinforced Concrete Columns and Isolated Footing Design
15 Chapter 15: Steel, Timber & Prestressed Design and Materials Testing
15.1 Structural Steel Tension Members and Connections 15.2 Structural Steel Compression Members and Beam Design 15.3 Timber Design Principles, Working Stress, and Sawn Lumber Beams 15.4 Prestressed Concrete Fundamentals and Prestress Losses 15.5 Construction Materials Testing and Concrete Mix Proportioning
14.1 Ultimate Strength Design (USD) Principles and Singly Reinforced Beams
Key Takeaways Explain This Topic AI
The Ultimate Strength Design (USD) philosophy requires the design flexural strength to equal or exceed the factored design moment: ϕ M n ≥ M u \phi M_n \ge M_u ϕ M n ≥ M u , where load factors account for overload uncertainties and strength reduction factors ( ϕ \phi ϕ ) account for dimensional variations and material understrength.
Under NSCP 2015 / ACI 318, Whitney's equivalent rectangular stress block assumes an average concrete compressive stress of 0.85 f c ′ 0.85 f'_c 0.85 f c ′ acting over depth a = β 1 c a = \beta_1 c a = β 1 c , where β 1 = 0.85 \beta_1 = 0.85 β 1 = 0.85 for f c ′ ≤ 28 MPa f'_c \le 28\text{ MPa} f c ′ ≤ 28 MPa and decreases by 0.05 per 7 MPa above 28 MPa down to a minimum floor of 0.65.
The strength reduction factor ϕ \phi ϕ depends directly on the net tensile strain ϵ t \epsilon_t ϵ t in the extreme tension steel: tension-controlled sections have ϵ t ≥ 0.005 \epsilon_t \ge 0.005 ϵ t ≥ 0.005 with ϕ = 0.90 \phi = 0.90 ϕ = 0.90 , transition sections have 0.002 ≤ ϵ t < 0.005 0.002 \le \epsilon_t < 0.005 0.002 ≤ ϵ t < 0.005 with linearly interpolated ϕ = 0.65 + ( ϵ t − 0.002 ) ( 250 / 3 ) \phi = 0.65 + (\epsilon_t - 0.002)(250/3) ϕ = 0.65 + ( ϵ t − 0.002 ) ( 250/3 ) , and compression-controlled tied sections have ϵ t ≤ 0.002 \epsilon_t \le 0.002 ϵ t ≤ 0.002 with ϕ = 0.65 \phi = 0.65 ϕ = 0.65 .
The balanced reinforcement ratio ρ b = 0.85 f c ′ β 1 f y ( 600 600 + f y ) \rho_b = \frac{0.85 f'_c \beta_1}{f_y} \left(\frac{600}{600 + f_y}\right) ρ b = f y 0.85 f c ′ β 1 ( 600 + f y 600 ) defines simultaneous yielding of steel and crushing of concrete at ϵ u = 0.003 \epsilon_u = 0.003 ϵ u = 0.003 ; modern codes enforce ductile failure by setting ρ max \rho_{\max} ρ m a x corresponding to ϵ t = 0.005 \epsilon_t = 0.005 ϵ t = 0.005 (or 0.75 ρ b 0.75 \rho_b 0.75 ρ b under legacy codes).
The minimum reinforcement ratio ρ min = max ( f c ′ 4 f y , 1.4 f y ) \rho_{\min} = \max\left(\frac{\sqrt{f'_c}}{4 f_y}, \frac{1.4}{f_y}\right) ρ m i n = max ( 4 f y f c ′ , f y 1.4 ) ensures that the nominal flexural strength upon initial concrete cracking exceeds the cracking moment M c r M_{cr} M cr , preventing sudden catastrophic brittle rupture.
Last updated: October 2026
14.1 Ultimate Strength Design (USD) Principles and Singly Reinforced Beams
Reinforced concrete design in the Philippines is governed by the National Structural Code of the Philippines (NSCP 2015, Volume 1, 7th Edition) , which largely mirrors the provisions of ACI 318M-14 . In modern structural practice and the PRC Civil Engineering Licensure Examination (CELE), the Ultimate Strength Design (USD) method—also known as the Strength Design Method—is the standard for proportioning structural concrete members. USD replaces the historical Working Stress Design (WSD) by applying explicit load factors to service loads and strength reduction factors ( ϕ \phi ϕ ) to nominal member resistances, providing a consistent margin of safety against structural collapse.
1. Ultimate Strength Design (USD) Philosophy
The fundamental safety criterion of Ultimate Strength Design dictates that the design strength provided by a structural component must equal or exceed the required strength generated by factored service loads:
ϕ R n ≥ U ⟹ ϕ M n ≥ M u \phi R_n \ge U \quad \implies \quad \phi M_n \ge M_u ϕ R n ≥ U ⟹ ϕ M n ≥ M u
Where:
M u M_u M u = factored design bending moment calculated from structural analysis under governing load combinations.
M n M_n M n = nominal flexural moment strength computed using theoretical equilibrium and strain compatibility.
ϕ \phi ϕ = strength reduction factor accounting for structural importance, dimensional tolerances, and the relative ductility of the failure mode.
NSCP 2015 Basic Factored Load Combinations
Under NSCP 2015 Section 203.3 / Section 405.3, the primary factored gravity and lateral load combinations include:
U = 1.4 D U = 1.4 D U = 1.4 D
U = 1.2 D + 1.6 L + 0.5 ( L r or R ) U = 1.2 D + 1.6 L + 0.5 (L_r \text{ or } R) U = 1.2 D + 1.6 L + 0.5 ( L r or R )
- U = 1.2 D + 1.0 L + 1.0 W U = 1.2 D + 1.0 L + 1.0 W U = 1.2 D + 1.0 L + 1.0 W
- U = 1.2 D + 1.0 L + 1.0 E U = 1.2 D + 1.0 L + 1.0 E U = 1.2 D + 1.0 L + 1.0 E
- U = 0.9 D + 1.0 W U = 0.9 D + 1.0 W U = 0.9 D + 1.0 W
- U = 0.9 D + 1.0 E U = 0.9 D + 1.0 E U = 0.9 D + 1.0 E
Where D D D is dead load, L L L is live load, L r L_r L r is roof live load, R R R is rain load, W W W is wind load, and E E E is earthquake load.
2. Fundamental Assumptions for Flexure
Flexural analysis of reinforced concrete relies on five foundational physical assumptions specified in NSCP 2015 Section 422:
Strain Linearity: Plane sections perpendicular to the longitudinal axis before bending remain plane after bending (Navier-Bernoulli hypothesis). Consequently, strain in both concrete and steel varies directly with distance from the neutral axis ( c c c ).
Maximum Usable Concrete Strain: The maximum usable compressive strain at the extreme concrete compression fiber is taken as ϵ u = 0.003 \epsilon_u = 0.003 ϵ u = 0.003 at ultimate limit state.
Tensile Strength Neglected: The tensile strength of concrete is completely ignored in flexural strength calculations because concrete cracks at low tensile strains (tensile rupture modulus f r = 0.62 λ f c ′ MPa f_r = 0.62 \lambda \sqrt{f'_c}\text{ MPa} f r = 0.62 λ f c ′ MPa ).
Elastoplastic Steel Behavior: Reinforcing steel behaves as a linear-elastic, perfectly plastic material. For strains less than yield strain ϵ y = f y / E s \epsilon_y = f_y / E_s ϵ y = f y / E s , steel stress is f s = E s ϵ s f_s = E_s \epsilon_s f s = E s ϵ s . For ϵ s ≥ ϵ y \epsilon_s \ge \epsilon_y ϵ s ≥ ϵ y , steel stress remains constant at f s = f y f_s = f_y f s = f y . Modulus of elasticity of steel is taken as E s = 200 , 000 MPa E_s = 200,000\text{ MPa} E s = 200 , 000 MPa .
Perfect Bond: Strain compatibility exists between reinforcing bars and surrounding concrete; no slip occurs prior to ultimate capacity.
3. Whitney's Equivalent Rectangular Stress Block
At ultimate flexural capacity, the true stress distribution in the concrete compression zone is non-linear and parabolic. Charles S. Whitney proposed an equivalent rectangular stress block that yields identical resultant compressive force ( C c C_c C c ) and line of action to the actual stress envelope.
Under NSCP 2015 Section 422.2.2.4:
An equivalent uniform compressive stress of 0.85 f c ′ 0.85 f'_c 0.85 f c ′ is assumed to act over an equivalent depth a a a bounded by edges of the cross-section and a line parallel to the neutral axis at distance a = β 1 c a = \beta_1 c a = β 1 c from the extreme compression fiber.
The resultant compressive force of the concrete is:
C c = 0.85 f c ′ a b C_c = 0.85 f'_c a b C c = 0.85 f c ′ ab
The resultant acts at a distance of a / 2 a/2 a /2 from the extreme compression fiber.
Stress Block Factor β 1 \beta_1 β 1
The factor β 1 \beta_1 β 1 relates equivalent stress block depth a a a to true neutral axis depth c c c ( a = β 1 c a = \beta_1 c a = β 1 c ):
β 1 = 0.85 for 17 MPa ≤ f c ′ ≤ 28 MPa \beta_1 = 0.85 \quad \text{for } 17\text{ MPa} \le f'_c \le 28\text{ MPa} β 1 = 0.85 for 17 MPa ≤ f c ′ ≤ 28 MPa
β 1 = 0.85 − 0.05 ( f c ′ − 28 ) 7 for f c ′ > 28 MPa \beta_1 = 0.85 - \frac{0.05 (f'_c - 28)}{7} \quad \text{for } f'_c > 28\text{ MPa} β 1 = 0.85 − 7 0.05 ( f c ′ − 28 ) for f c ′ > 28 MPa
β 1 ≥ 0.65 ( absolute lower limit ) \beta_1 \ge 0.65 \quad (\text{absolute lower limit}) β 1 ≥ 0.65 ( absolute lower limit )
- Specified Concrete Strength f c ′ f'_c f c ′ Stress Block Depth Factor β 1 \beta_1 β 1
- ≤ 28 MPa \le 28\text{ MPa} ≤ 28 MPa ( 4000 psi 4000\text{ psi} 4000 psi ) 0.850 0.850 0.850
- 30 MPa 30\text{ MPa} 30 MPa 0.836 0.836 0.836
- 35 MPa 35\text{ MPa} 35 MPa ( 5000 psi 5000\text{ psi} 5000 psi ) 0.800 0.800 0.800
- 40 MPa 40\text{ MPa} 40 MPa 0.764 0.764 0.764
- 42 MPa 42\text{ MPa} 42 MPa ( 6000 psi 6000\text{ psi} 6000 psi ) 0.750 0.750 0.750
- ≥ 56 MPa \ge 56\text{ MPa} ≥ 56 MPa ( 8000 psi 8000\text{ psi} 8000 psi ) 0.650 0.650 0.650 (minimum floor)
- 4. Strain Compatibility and Strength Reduction Factor ( ϕ \phi ϕ )
The behavior and ductility of a beam cross-section are governed by the net tensile strain ( ϵ t \epsilon_t ϵ t ) in the extreme layer of longitudinal tension steel at nominal strength.
From similar triangles in the linear strain diagram:
ϵ u c = ϵ t d t − c ⟹ ϵ t = 0.003 ( d t − c c ) \frac{\epsilon_u}{c} = \frac{\epsilon_t}{d_t - c} \implies \epsilon_t = 0.003 \left(\frac{d_t - c}{c}\right) c ϵ u = d t − c ϵ t ⟹ ϵ t = 0.003 ( c d t − c )
where d t d_t d t is the distance from extreme compression fiber to the centroid of the extreme tension steel layer (equal to effective depth d d d for a single layer of steel). COMPRESSION FIBER
- ---------------- <-- Strain = ε_u = 0.003
- | /
- | /
- | /
- c | / (Neutral Axis)
- - - -|- / - - - - - - - - - - - -
- | /
- |/
- (d - c)|
- |\
- | \
- ------|--\---- <-- Strain = ε_t (Tension Steel)
- Section Classification and ϕ \phi ϕ Values (NSCP 2015 Table 421.2.1)
Tension-Controlled Section ( ϵ t ≥ 0.005 \epsilon_t \ge 0.005 ϵ t ≥ 0.005 ):
Steel yields substantially before concrete reaches ϵ u = 0.003 \epsilon_u = 0.003 ϵ u = 0.003 .
Warning of failure through large deflections and wide cracking.
ϕ = 0.90 \phi = 0.90 ϕ = 0.90 .
Transition Zone ( 0.002 ≤ ϵ t < 0.005 0.002 \le \epsilon_t < 0.005 0.002 ≤ ϵ t < 0.005 for Grade 420 steel):
Steel yields, but ductility is reduced.
Strength reduction factor is linearly interpolated: ϕ = 0.65 + ( ϵ t − 0.002 ) ( 250 3 ) = 0.65 + 0.25 ( ϵ t − 0.002 0.003 ) \phi = 0.65 + (\epsilon_t - 0.002) \left(\frac{250}{3}\right) = 0.65 + 0.25 \left(\frac{\epsilon_t - 0.002}{0.003}\right) ϕ = 0.65 + ( ϵ t − 0.002 ) ( 3 250 ) = 0.65 + 0.25 ( 0.003 ϵ t − 0.002 )
Compression-Controlled Section ( ϵ t ≤ ϵ y ≈ 0.002 \epsilon_t \le \epsilon_y \approx 0.002 ϵ t ≤ ϵ y ≈ 0.002 ):
Brittle, explosive crushing of concrete before steel yields.
ϕ = 0.65 \phi = 0.65 ϕ = 0.65 for members with transverse ties.
ϕ = 0.75 \phi = 0.75 ϕ = 0.75 for members with continuous circular spirals.
5. Reinforcement Ratios: Balanced, Maximum, and Minimum
The steel reinforcement ratio is defined as:
- ρ = A s b d \rho = \frac{A_s}{b d} ρ = b d A s
- Internal Force Equilibrium
For a singly reinforced rectangular beam with tension steel yielding ( f s = f y f_s = f_y f s = f y ):
C c = T ⟹ 0.85 f c ′ a b = A s f y C_c = T \implies 0.85 f'_c a b = A_s f_y C c = T ⟹ 0.85 f c ′ ab = A s f y
a = A s f y 0.85 f c ′ b = ρ f y d 0.85 f c ′ a = \frac{A_s f_y}{0.85 f'_c b} = \frac{\rho f_y d}{0.85 f'_c} a = 0.85 f c ′ b A s f y = 0.85 f c ′ ρ f y d
c = a β 1 = ρ f y d 0.85 β 1 f c ′ c = \frac{a}{\beta_1} = \frac{\rho f_y d}{0.85 \beta_1 f'_c} c = β 1 a = 0.85 β 1 f c ′ ρ f y d
Balanced Reinforcement Ratio ( ρ b \rho_b ρ b )
A balanced condition occurs when the extreme concrete compression fiber reaches strain ϵ u = 0.003 \epsilon_u = 0.003 ϵ u = 0.003 simultaneously as the tension reinforcement reaches its initial yield strain ϵ y = f y / E s \epsilon_y = f_y / E_s ϵ y = f y / E s :
c b d = ϵ u ϵ u + ϵ y = 0.003 0.003 + f y / 200000 = 600 600 + f y \frac{c_b}{d} = \frac{\epsilon_u}{\epsilon_u + \epsilon_y} = \frac{0.003}{0.003 + f_y / 200000} = \frac{600}{600 + f_y} d c b = ϵ u + ϵ y ϵ u = 0.003 + f y /200000 0.003 = 600 + f y 600
Equating C c = T C_c = T C c = T at balanced conditions yields:
ρ b = 0.85 f c ′ β 1 f y ( 600 600 + f y ) \rho_b = \frac{0.85 f'_c \beta_1}{f_y} \left(\frac{600}{600 + f_y}\right) ρ b = f y 0.85 f c ′ β 1 ( 600 + f y 600 )
Maximum Reinforcement Ratio ( ρ max \rho_{\max} ρ m a x )
To ensure ductile behavior and prevent sudden brittle compression failures:
NSCP 2015 / ACI 318 Tension-Controlled Limit: The design requires ϵ t ≥ 0.005 \epsilon_t \ge 0.005 ϵ t ≥ 0.005 to use ϕ = 0.90 \phi = 0.90 ϕ = 0.90 . Setting ϵ t = 0.005 \epsilon_t = 0.005 ϵ t = 0.005 at d t = d d_t = d d t = d : c d = 0.003 0.003 + 0.005 = 3 8 = 0.375 \frac{c}{d} = \frac{0.003}{0.003 + 0.005} = \frac{3}{8} = 0.375 d c = 0.003 + 0.005 0.003 = 8 3 = 0.375 ρ max = 0.85 f c ′ β 1 f y ( 0.375 ) = 0.85 f c ′ β 1 f y ( 3 8 ) \rho_{\max} = \frac{0.85 f'_c \beta_1}{f_y} (0.375) = \frac{0.85 f'_c \beta_1}{f_y} \left(\frac{3}{8}\right) ρ m a x = f y 0.85 f c ′ β 1 ( 0.375 ) = f y 0.85 f c ′ β 1 ( 8 3 )
NSCP 2001 (Legacy Code Limit): Often still referenced in CELE problems: ρ max = 0.75 ρ b \rho_{\max} = 0.75 \rho_b ρ m a x = 0.75 ρ b
Minimum Reinforcement Ratio ( ρ min \rho_{\min} ρ m i n )
If a beam has too little reinforcement, the flexural capacity of the uncracked concrete section ( M c r M_{cr} M cr ) may exceed the nominal capacity of the reinforced cracked section ( M n M_n M n ), leading to immediate catastrophic rupture upon initial cracking. NSCP 2015 Section 409.6.1.2 mandates:
A s , min = f c ′ 4 f y b w d ≥ 1.4 f y b w d A_{s,\min} = \frac{\sqrt{f'_c}}{4 f_y} b_w d \ge \frac{1.4}{f_y} b_w d A s , m i n = 4 f y f c ′ b w d ≥ f y 1.4 b w d
ρ min = max ( f c ′ 4 f y , 1.4 f y ) \rho_{\min} = \max\left(\frac{\sqrt{f'_c}}{4 f_y}, \quad \frac{1.4}{f_y}\right) ρ m i n = max ( 4 f y f c ′ , f y 1.4 )
(Note: f c ′ 4 f y \frac{\sqrt{f'_c}}{4 f_y} 4 f y f c ′ governs when f c ′ > 31.36 MPa f'_c > 31.36\text{ MPa} f c ′ > 31.36 MPa ; otherwise 1.4 f y \frac{1.4}{f_y} f y 1.4 governs.)
6. Nominal and Design Flexural Capacity
Once the depth of the compression block a a a is obtained, the internal moment arm is ( d − a / 2 ) (d - a/2) ( d − a /2 ) . The nominal flexural strength is:
M n = T ( d − a 2 ) = A s f y ( d − a 2 ) M_n = T \left(d - \frac{a}{2}\right) = A_s f_y \left(d - \frac{a}{2}\right) M n = T ( d − 2 a ) = A s f y ( d − 2 a )
Expressed in terms of the reinforcement ratio ρ \rho ρ :
M n = ρ f y b d 2 ( 1 − 0.59 ρ f y f c ′ ) = R n b d 2 M_n = \rho f_y b d^2 \left(1 - 0.59 \frac{\rho f_y}{f'_c}\right) = R_n b d^2 M n = ρ f y b d 2 ( 1 − 0.59 f c ′ ρ f y ) = R n b d 2
Where the coefficient of resistance R n R_n R n is:
R n = ρ f y ( 1 − 0.59 ρ f y f c ′ ) R_n = \rho f_y \left(1 - 0.59 \frac{\rho f_y}{f'_c}\right) R n = ρ f y ( 1 − 0.59 f c ′ ρ f y )
The design moment capacity is:
- ϕ M n = ϕ R n b d 2 ≥ M u \phi M_n = \phi R_n b d^2 \ge M_u ϕ M n = ϕ R n b d 2 ≥ M u
- 7. Step-by-Step Analysis vs. Design Procedures
Analysis of a Given Cross-Section ( b , d , A s , f c ′ , f y b, d, A_s, f'_c, f_y b , d , A s , f c ′ , f y known):
Calculate ρ = A s / ( b d ) \rho = A_s / (b d) ρ = A s / ( b d ) . Verify that ρ ≥ ρ min \rho \ge \rho_{\min} ρ ≥ ρ m i n .
Compute a = A s f y 0.85 f c ′ b a = \frac{A_s f_y}{0.85 f'_c b} a = 0.85 f c ′ b A s f y and determine β 1 \beta_1 β 1 .
Calculate neutral axis depth c = a / β 1 c = a / \beta_1 c = a / β 1 .
Calculate extreme tension steel strain ϵ t = 0.003 d t − c c \epsilon_t = 0.003 \frac{d_t - c}{c} ϵ t = 0.003 c d t − c .
If ϵ t ≥ ϵ y \epsilon_t \ge \epsilon_y ϵ t ≥ ϵ y , steel has yielded ( f s = f y f_s = f_y f s = f y ).
If ϵ t < ϵ y \epsilon_t < \epsilon_y ϵ t < ϵ y , recalculate c c c using quadratic equilibrium: 0.85 f c ′ β 1 b c 2 + 600 A s c − 600 A s d = 0 0.85 f'_c \beta_1 b c^2 + 600 A_s c - 600 A_s d = 0 0.85 f c ′ β 1 b c 2 + 600 A s c − 600 A s d = 0 .
Determine ϕ \phi ϕ based on ϵ t \epsilon_t ϵ t ( ϕ = 0.90 \phi = 0.90 ϕ = 0.90 if ϵ t ≥ 0.005 \epsilon_t \ge 0.005 ϵ t ≥ 0.005 ).
Compute M n = A s f y ( d − a / 2 ) M_n = A_s f_y (d - a/2) M n = A s f y ( d − a /2 ) and design strength ϕ M n \phi M_n ϕ M n .
Design of Beam Reinforcement ( M u , b , d , f c ′ , f y M_u, b, d, f'_c, f_y M u , b , d , f c ′ , f y given):
Assume tension-controlled behavior ( ϕ = 0.90 \phi = 0.90 ϕ = 0.90 ).
Compute required resistance factor: R n = M u ϕ b d 2 R_n = \frac{M_u}{\phi b d^2} R n = ϕ b d 2 M u .
Solve for required reinforcement ratio ρ \rho ρ : ρ = 0.85 f c ′ f y ( 1 − 1 − 2 R n 0.85 f c ′ ) \rho = \frac{0.85 f'_c}{f_y} \left(1 - \sqrt{1 - \frac{2 R_n}{0.85 f'_c}}\right) ρ = f y 0.85 f c ′ ( 1 − 1 − 0.85 f c ′ 2 R n )
Verify that ρ min ≤ ρ ≤ ρ max \rho_{\min} \le \rho \le \rho_{\max} ρ m i n ≤ ρ ≤ ρ m a x . If ρ > ρ max \rho > \rho_{\max} ρ > ρ m a x , enlarge the beam cross-section or design as a doubly reinforced beam.
Compute required steel area A s = ρ b d A_s = \rho b d A s = ρ b d and select suitable bar diameter and quantity.
- 8. Comprehensive Worked Examples
- Worked Example 1: Analysis of a Singly Reinforced Rectangular Beam
Problem: A reinforced concrete beam has a width of b = 300 mm b = 300\text{ mm} b = 300 mm , an overall depth of h = 550 mm h = 550\text{ mm} h = 550 mm , and an effective depth of d = 485 mm d = 485\text{ mm} d = 485 mm . It is reinforced with 4 − ϕ 25 mm 4 - \phi 25\text{ mm} 4 − ϕ 25 mm bars in a single layer. Specified material strengths are f c ′ = 28 MPa f'_c = 28\text{ MPa} f c ′ = 28 MPa and f y = 420 MPa f_y = 420\text{ MPa} f y = 420 MPa . Determine: (a) depth of the equivalent stress block, (b) extreme tension steel strain ϵ t \epsilon_t ϵ t , (c) nominal flexural strength M n M_n M n , and (d) design moment capacity ϕ M n \phi M_n ϕ M n .
Solution:
Step 1: Section Properties and Steel Area: A s = 4 × ( π 4 × 25 2 ) = 4 × 490.87 = 1963.5 mm 2 A_s = 4 \times \left(\frac{\pi}{4} \times 25^2\right) = 4 \times 490.87 = 1963.5\text{ mm}^2 A s = 4 × ( 4 π × 2 5 2 ) = 4 × 490.87 = 1963.5 mm 2 ρ = A s b d = 1963.5 300 × 485 = 0.013495 ( 1.35 % \rho = \frac{A_s}{b d} = \frac{1963.5}{300 \times 485} = 0.013495 \quad (1.35\% ρ = b d A s = 300 × 485 1963.5 = 0.013495 ( 1.35%
Step 2: Check Code Limits: ρ min = max ( 28 4 × 420 , 1.4 420 ) = max ( 0.00315 , 0.00333 ) = 0.00333 \rho_{\min} = \max\left(\frac{\sqrt{28}}{4 \times 420}, \frac{1.4}{420}\right) = \max(0.00315, 0.00333) = 0.00333 ρ m i n = max ( 4 × 420 28 , 420 1.4 ) = max ( 0.00315 , 0.00333 ) = 0.00333 Since ρ = 0.0135 > 0.00333 \rho = 0.0135 > 0.00333 ρ = 0.0135 > 0.00333 , minimum steel requirement is satisfied.
For f c ′ = 28 MPa ⟹ β 1 = 0.85 f'_c = 28\text{ MPa} \implies \beta_1 = 0.85 f c ′ = 28 MPa ⟹ β 1 = 0.85 . ρ b = 0.85 ( 28 ) ( 0.85 ) 420 ( 600 600 + 420 ) = 0.048167 × 0.588235 = 0.02833 \rho_b = \frac{0.85(28)(0.85)}{420} \left(\frac{600}{600 + 420}\right) = 0.048167 \times 0.588235 = 0.02833 ρ b = 420 0.85 ( 28 ) ( 0.85 ) ( 600 + 420 600 ) = 0.048167 × 0.588235 = 0.02833 ρ max ( ϵ t = 0.005 ) = 0.85 ( 28 ) ( 0.85 ) 420 × 0.375 = 0.01806 \rho_{\max} (\epsilon_t = 0.005) = \frac{0.85(28)(0.85)}{420} \times 0.375 = 0.01806 ρ m a x ( ϵ t = 0.005 ) = 420 0.85 ( 28 ) ( 0.85 ) × 0.375 = 0.01806 Since ρ = 0.0135 < 0.01806 \rho = 0.0135 < 0.01806 ρ = 0.0135 < 0.01806 , the section is guaranteed to be tension-controlled.
Step 3: Depth of Equivalent Stress Block ( a a a ) and Neutral Axis ( c c c ): a = A s f y 0.85 f c ′ b = 1963.5 × 420 0.85 × 28 × 300 = 824 , 670 7 , 140 = 115.50 mm a = \frac{A_s f_y}{0.85 f'_c b} = \frac{1963.5 \times 420}{0.85 \times 28 \times 300} = \frac{824,670}{7,140} = 115.50\text{ mm} a = 0.85 f c ′ b A s f y = 0.85 × 28 × 300 1963.5 × 420 = 7 , 140 824 , 670 = 115.50 mm c = a β 1 = 115.50 0.85 = 135.88 mm c = \frac{a}{\beta_1} = \frac{115.50}{0.85} = 135.88\text{ mm} c = β 1 a = 0.85 115.50 = 135.88 mm
Step 4: Check Tensile Strain and Determine ϕ \phi ϕ : With a single layer of steel, d t = d = 485 mm d_t = d = 485\text{ mm} d t = d = 485 mm : ϵ t = 0.003 ( d t − c c ) = 0.003 ( 485 − 135.88 135.88 ) = 0.003 ( 349.12 135.88 ) = 0.00771 \epsilon_t = 0.003 \left(\frac{d_t - c}{c}\right) = 0.003 \left(\frac{485 - 135.88}{135.88}\right) = 0.003 \left(\frac{349.12}{135.88}\right) = 0.00771 ϵ t = 0.003 ( c d t − c ) = 0.003 ( 135.88 485 − 135.88 ) = 0.003 ( 135.88 349.12 ) = 0.00771 Since ϵ t = 0.00771 > 0.005 \epsilon_t = 0.00771 > 0.005 ϵ t = 0.00771 > 0.005 , the beam is fully tension-controlled ⟹ ϕ = 0.90 \implies \phi = 0.90 ⟹ ϕ = 0.90 .
Step 5: Nominal and Design Flexural Strengths: M n = A s f y ( d − a 2 ) = 1963.5 × 420 × ( 485 − 115.50 2 ) × 10 − 6 M_n = A_s f_y \left(d - \frac{a}{2}\right) = 1963.5 \times 420 \times \left(485 - \frac{115.50}{2}\right) \times 10^{-6} M n = A s f y ( d − 2 a ) = 1963.5 × 420 × ( 485 − 2 115.50 ) × 1 0 − 6 M n = 824.670 × 427.25 × 10 − 3 = 352.34 kN ⋅ m M_n = 824.670 \times 427.25 \times 10^{-3} = 352.34\text{ kN}\cdot\text{m} M n = 824.670 × 427.25 × 1 0 − 3 = 352.34 kN ⋅ m ϕ M n = 0.90 × 352.34 = 317.11 kN ⋅ m \phi M_n = 0.90 \times 352.34 = 317.11\text{ kN}\cdot\text{m} ϕ M n = 0.90 × 352.34 = 317.11 kN ⋅ m
Worked Example 2: Flexural Design of a Singly Reinforced Beam
Problem: A simply supported rectangular beam with b = 300 mm b = 300\text{ mm} b = 300 mm and effective depth d = 500 mm d = 500\text{ mm} d = 500 mm must resist a factored moment of M u = 260 kN ⋅ m M_u = 260\text{ kN}\cdot\text{m} M u = 260 kN ⋅ m . Material strengths are f c ′ = 21 MPa f'_c = 21\text{ MPa} f c ′ = 21 MPa and f y = 420 MPa f_y = 420\text{ MPa} f y = 420 MPa . Design the required tension reinforcement area A s A_s A s .
Solution:
Step 1: Compute Required Resistance Factor ( R n R_n R n ): Assuming a tension-controlled section ( ϕ = 0.90 \phi = 0.90 ϕ = 0.90 ): R n = M u ϕ b d 2 = 260 × 10 6 0.90 × 300 × 500 2 = 260 × 10 6 67.5 × 10 6 = 3.8519 MPa R_n = \frac{M_u}{\phi b d^2} = \frac{260 \times 10^6}{0.90 \times 300 \times 500^2} = \frac{260 \times 10^6}{67.5 \times 10^6} = 3.8519\text{ MPa} R n = ϕ b d 2 M u = 0.90 × 300 × 50 0 2 260 × 1 0 6 = 67.5 × 1 0 6 260 × 1 0 6 = 3.8519 MPa
Step 2: Calculate Required Reinforcement Ratio ( ρ \rho ρ ): ρ = 0.85 ( 21 ) 420 ( 1 − 1 − 2 ( 3.8519 ) 0.85 ( 21 ) ) = 0.0425 × ( 1 − 1 − 0.43158 ) \rho = \frac{0.85(21)}{420} \left(1 - \sqrt{1 - \frac{2(3.8519)}{0.85(21)}}\right) = 0.0425 \times \left(1 - \sqrt{1 - 0.43158}\right) ρ = 420 0.85 ( 21 ) ( 1 − 1 − 0.85 ( 21 ) 2 ( 3.8519 ) ) = 0.0425 × ( 1 − 1 − 0.43158 ) ρ = 0.0425 × ( 1 − 0.56842 ) = 0.0425 × ( 1 − 0.75394 ) = 0.010458 ( 1.05 % \rho = 0.0425 \times (1 - \sqrt{0.56842}) = 0.0425 \times (1 - 0.75394) = 0.010458 \quad (1.05\% ρ = 0.0425 × ( 1 − 0.56842 ) = 0.0425 × ( 1 − 0.75394 ) = 0.010458 ( 1.05%
Step 3: Check Limits: ρ min = 1.4 420 = 0.00333 \rho_{\min} = \frac{1.4}{420} = 0.00333 ρ m i n = 420 1.4 = 0.00333 ρ max ( ϵ t = 0.005 ) = 0.85 ( 21 ) ( 0.85 ) 420 × 0.375 = 0.01355 \rho_{\max} (\epsilon_t = 0.005) = \frac{0.85(21)(0.85)}{420} \times 0.375 = 0.01355 ρ m a x ( ϵ t = 0.005 ) = 420 0.85 ( 21 ) ( 0.85 ) × 0.375 = 0.01355 Since 0.00333 ≤ ρ = 0.01046 ≤ 0.01355 0.00333 \le \rho = 0.01046 \le 0.01355 0.00333 ≤ ρ = 0.01046 ≤ 0.01355 , the tension-controlled assumption ϕ = 0.90 \phi = 0.90 ϕ = 0.90 is fully validated.
Step 4: Compute Required Area of Steel: A s = ρ b d = 0.010458 × 300 × 500 = 1568.7 mm 2 A_s = \rho b d = 0.010458 \times 300 \times 500 = 1568.7\text{ mm}^2 A s = ρ b d = 0.010458 × 300 × 500 = 1568.7 mm 2 Selection: Using 28 mm 28\text{ mm} 28 mm bars ( A b = 615.75 mm 2 A_b = 615.75\text{ mm}^2 A b = 615.75 mm 2 ): N = 1568.7 615.75 = 2.55 ⟹ Provide 3 − ϕ 28 mm ( A s = 1847 mm 2 ) N = \frac{1568.7}{615.75} = 2.55 \implies \text{Provide } 3 - \phi 28\text{ mm} \quad (A_s = 1847\text{ mm}^2) N = 615.75 1568.7 = 2.55 ⟹ Provide 3 − ϕ 28 mm ( A s = 1847 mm 2 )
9. Licensure Exam Pitfalls & Review Notes
Warning
Pitfall 1: Confusing Stress Block Depth a a a with Neutral Axis Depth c c c Whitney's equivalent block depth a a a is NOT the neutral axis depth c c c . The neutral axis is located at c = a / β 1 c = a / \beta_1 c = a / β 1 . In strain compatibility equations ( ϵ t = 0.003 d t − c c \epsilon_t = 0.003 \frac{d_t - c}{c} ϵ t = 0.003 c d t − c ), candidates frequently plug in a a a instead of c c c , resulting in erroneously high calculated strains and incorrect ϕ \phi ϕ factors.
Caution
Pitfall 2: Value of β 1 \beta_1 β 1 for High-Strength Concrete The factor β 1 \beta_1 β 1 drops below 0.85 0.85 0.85 whenever f c ′ > 28 MPa f'_c > 28\text{ MPa} f c ′ > 28 MPa . However, β 1 \beta_1 β 1 never drops below 0.65 0.65 0.65 . For f c ′ = 60 MPa f'_c = 60\text{ MPa} f c ′ = 60 MPa , calculating 0.85 − 0.05 ( 60 − 28 ) / 7 = 0.621 0.85 - 0.05(60 - 28)/7 = 0.621 0.85 − 0.05 ( 60 − 28 ) /7 = 0.621 is wrong—the code enforces a strict floor of β 1 = 0.65 \beta_1 = 0.65 β 1 = 0.65 .
Tip
Pitfall 3: Distinction Between d d d and d t d_t d t When reinforcement is placed in two or more layers, d d d is measured to the centroid of the total steel group, whereas d t d_t d t is measured to the center of the extreme tension bar layer closest to the tension face. Net tensile strain ϵ t \epsilon_t ϵ t must be computed using d t d_t d t , NOT d d d .