13.4 NSCP Minimum Design Loads: Dead, Live, Wind, and Earthquake
PRC Civil Engineer Licensure Examination CELE
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Examination Overview, RA 544 & Professional Practice
1.1 CELE Structure, Format, Scoring, and 2026 Subject Order 1.2 Republic Act No. 544: The Civil Engineering Law and Board Regulations 1.3 Civil Engineering Ethics, Contracts, and Professional Practice
2 Chapter 2: Engineering Mathematics, Numerical Methods & Physics
2.1 Advanced Algebra, Progressions & Word Problems 2.2 Trigonometry and Analytical Geometry 2.3 Differential and Integral Calculus 2.4 Differential Equations and Numerical Methods 2.5 Series, Hyperbolic Functions, Multivariable Calculus, and Laplace Transforms 2.6 Numerical Methods: Linear Systems, Interpolation, Curve Fitting, and ODE Solvers 2.7 Physics for Engineers: Kinematics, Newton's Laws, Work-Energy, and Momentum
3 Chapter 3: Engineering Data Analysis & Engineering Economy
3.1 Engineering Data Analysis and Statistical Applications 3.2 Parameter Estimation, Linear Regression, Correlation, and Queuing Models 3.3 Engineering Economy: Time Value of Money and Interest Formulas 3.4 Project Evaluation, Depreciation, and Benefit-Cost Analysis
4 Chapter 4: Surveying Fundamentals, Construction Layout & Route Surveying
4.1 Errors, Corrections, and Pacing/Taping 4.2 Leveling, Earthworks, and Mass Haul Diagrams 4.3 Traverse Computations, Balancing, and Area Determinations 4.4 Route Surveying: Horizontal and Vertical Curves
5 Chapter 5: Highway & Transportation Engineering
5.1 Highway Geometric Design and Sight Distances 5.2 Traffic Engineering, Flow Fundamentals, and Pavement Design 5.3 Highway Policy, Route Location, Drainage, and Earthwork Slopes 5.4 Transportation Planning, Network Analysis, and Intermodal Systems
6 Chapter 6: Construction Materials, Methods, Management & Safety
6.1 Materials for Construction: Concrete, Formwork, Masonry, Steel, and Wood Products 6.2 Construction Equipment, Formwork, and Construction Methods 6.3 Construction Occupational Safety and Health: RA 11058 and DOLE DO 13 6.4 Construction Project Management, CPM/PERT, and Resource Scheduling 6.5 Construction Principles: Design Requirements, Project Organization, Cost Control, and Value Engineering 6.6 Quantity Surveying, Unit Cost Analysis, and Project Cost Estimates 6.7 Construction Trades and Specialties: Plumbing, Plastics, Doors and Windows, Finishes, and Electrical
7 Chapter 7: Fluid Properties, Hydrostatics & Buoyancy
7.1 Fluid Properties, Units, and Pressure Measurement 7.2 Hydrostatic Pressure on Plane and Curved Surfaces 7.3 Buoyancy, Flotation, and Accelerated Fluid Masses
8 Chapter 8: Hydrodynamics, Pipe Flow, Open Channels & Water Supply
8.1 Fluid Dynamics: Continuity and Energy Equations 8.2 Flow Measurement: Orifices, Weirs, and Venturi Meters 8.3 Fluid Flow in Pipes, Friction Losses, and Pipe Networks 8.4 Open Channel Flow, Manning's Equation, and Hydraulic Jump 8.5 Water Supply: Demand, Storage, Pumping, Distribution, and Treatment
9 Chapter 9: Soil Properties, Seepage & Stresses in Soil Mass
9.1 Soil Composition, Weight-Volume Phase Relationships 9.2 Soil Classification Systems (USCS & AASHTO) and Atterberg Limits 9.3 Soil Permeability, Seepage, Flow Nets, and Effective Stress 9.4 Stresses in Soil Mass, Stress Distribution, and Immediate and Secondary Settlement
10 Chapter 10: Consolidation, Soil Strength, Earth Pressures & Foundations
10.1 Soil Compaction and Soil Compressibility/Consolidation 10.2 Shear Strength of Soils and Mohr-Coulomb Failure Criteria 10.3 Lateral Earth Pressures (Rankine & Coulomb) and Retaining Walls 10.4 Shallow and Deep Foundation Bearing Capacity and Slope Stability
11 Chapter 11: Engineering Mechanics & Statics
11.1 Force Systems, Resultants, and Equilibrium of Rigid Bodies 11.2 Centroids, Moments of Inertia, and Friction 11.3 Cables, Trusses, and Internal Forces in Members
12 Chapter 12: Strength of Materials
12.1 Axial Stress, Strain, and Deformation 12.2 Torsion, Flanged Bolt Couplings, and Thin-Walled Pressure Vessels 12.3 Beam Stresses: Flexural and Transverse Shear 12.4 Beam Deflections, Combined Stresses, and Mohr's Circle
13 Chapter 13: Structural Analysis & NSCP Load Criteria
13.1 Indeterminate Structures: Approximate and Classical Methods 13.2 Moment Distribution Method and Slope Deflection 13.3 Influence Lines for Determinate and Indeterminate Structures 13.4 NSCP Minimum Design Loads: Dead, Live, Wind, and Earthquake
14 Chapter 14: Reinforced Concrete Design (NSCP 2015 / USD)
14.1 Ultimate Strength Design (USD) Principles and Singly Reinforced Beams 14.2 Doubly Reinforced Beams and T-Beams 14.3 Shear and Diagonal Tension, Stirrup Design, and Development Length 14.4 Reinforced Concrete Columns and Isolated Footing Design
15 Chapter 15: Steel, Timber & Prestressed Design and Materials Testing
15.1 Structural Steel Tension Members and Connections 15.2 Structural Steel Compression Members and Beam Design 15.3 Timber Design Principles, Working Stress, and Sawn Lumber Beams 15.4 Prestressed Concrete Fundamentals and Prestress Losses 15.5 Construction Materials Testing and Concrete Mix Proportioning
13.4 NSCP Minimum Design Loads: Dead, Live, Wind, and Earthquake
Key Takeaways Explain This Topic AI
NSCP 2015 Table 204-1 lists reinforced stone concrete at 23.6 kN/m³; board problems often specify 24 kN/m³, so always use the value given.
Live loads vary by occupancy classification (e.g., 1.9 kPa for basic residential/classrooms, 2.4 kPa for offices, 4.8 kPa for corridors), reducible via L = L_0 [0.25 + 4.57 / √A_I] for structural elements supporting influence areas A_I ≥ 37.2 m².
Strength Design (USD/LRFD) load combinations mandate governing factored load envelopes, notably 1.4D, 1.2D + 1.6L + 0.5(L_r or R), 1.2D + 1.0W + 1.0L, and seismic combinations 1.2D + 1.0E + 1.0L and 0.9D + 1.0E.
NSCP 2015 velocity pressure is q_z = 0.613 K_z K_zt K_d V² (N/m², V in m/s), with V read from the wind-speed contour map for the occupancy category.
Under the Equivalent Lateral Force (ELF) procedure, seismic base shear V = (C_v · I / R · T) · W is governed by upper limit V ≤ (2.5 C_a · I / R) · W and Zone 4 lower limit V ≥ (0.8 Z N_v · I / R) · W, with zone factor Z = 0.40 except in Zone 2 (Z = 0.20): Palawan (except Busuanga), Sulu and Tawi-Tawi.
Last updated: October 2026
13.4 NSCP Minimum Design Loads: Dead, Live, Wind, and Earthquake
Every structural design in the Philippines must comply with the legal mandates of the National Structural Code of the Philippines (NSCP 2015, Volume 1, 7th Edition) . Chapter 2 dictates the minimum design loads required to ensure structural safety, serviceability, and life preservation under gravity, extreme typhoons, and severe seismic events.
1. Dead Loads (NSCP Section 204)
Dead loads consist of the permanent weight of all materials of construction incorporated into the building, including walls, floors, roofs, ceilings, stairways, built-in partitions, finishes, and fixed service equipment.
Material Densities & Component Weights
NSCP 2015 gives Table 204-1 (minimum densities of materials, kN/m³) and Table 204-2 (minimum design dead loads of components, kPa). Representative values:
Material / Component Value used in design
Reinforced concrete, stone aggregate 23.6 kN/m 3 23.6\text{ kN/m}^3 23.6 kN/m 3 (Table 204-1); plain stone concrete 22.6 kN/m 3 22.6\text{ kN/m}^3 22.6 kN/m 3
Steel about 77 kN/m 3 77\text{ kN/m}^3 77 kN/m 3 (mass density about 7 , 850 kg/m 3 7,850\text{ kg/m}^3 7 , 850 kg/m 3 )
- Ceramic or quarry tile on 25 mm mortar bed about 1.10 kPa 1.10\text{ kPa} 1.10 kPa
- Concrete hollow block walls taken from Table 204-2 by block thickness and grout spacing
- Ceilings, mechanical and electrical allowances per Table 204-2 or the actual equipment weights
Tip
Many board problems state "use 24 kN/m³ for concrete." When a problem gives a unit weight, use it; when it says "per NSCP," use the tabulated value.
Movable Partition Allowance
In office buildings and commercial spaces where interior partitions are subject to rearrangement, a minimum uniformly distributed partition live/dead load allowance of 1.0 kPa 1.0\text{ kPa} 1.0 kPa must be included on the floor slab, regardless of whether partitions are shown on architectural drawings.
2. Live Loads & Reduction Formulas (NSCP Section 205)
Live loads are transient forces produced by the use and occupancy of the building, excluding environmental loads such as wind and earthquake.
- Minimum Uniform Live Loads (Table 205-1)
- Residential (Habitable rooms): 1.9 kPa 1.9\text{ kPa} 1.9 kPa
- Classrooms: 1.9 kPa 1.9\text{ kPa} 1.9 kPa
- Office Floors: 2.4 kPa 2.4\text{ kPa} 2.4 kPa (Lobbies: 4.8 kPa 4.8\text{ kPa} 4.8 kPa )
Corridors (above 1st floor): 3.8 kPa 3.8\text{ kPa} 3.8 kPa (1st floor corridors: 4.8 kPa 4.8\text{ kPa} 4.8 kPa )
- Light Storage Warehouse: 6.0 kPa 6.0\text{ kPa} 6.0 kPa
- Heavy Storage Warehouse: 12.0 kPa 12.0\text{ kPa} 12.0 kPa
- Flat and Pitched Roof Live Load ( L r L_r L r ): 1.0 kPa 1.0\text{ kPa} 1.0 kPa
- Live Load Reduction
Members supporting large tributary floor areas are statistically unlikely to experience full design live loading across all bays simultaneously. For structural members supporting an influence area A I ≥ 37.2 m 2 A_I \ge 37.2\text{ m}^2 A I ≥ 37.2 m 2 , the design live load may be reduced:
L = L 0 ( 0.25 + 4.57 A I ) L = L_0 \left( 0.25 + \frac{4.57}{\sqrt{A_I}} \right) L = L 0 ( 0.25 + A I 4.57 )
Where:
L L L = reduced design live load per square meter.
L 0 L_0 L 0 = unreduced basic design live load.
A I = K L L A T A_I = K_{LL} A_T A I = K LL A T = live load influence area ( m 2 \text{m}^2 m 2 ).
A T A_T A T = tributary area supported by the member ( m 2 \text{m}^2 m 2 ).
K L L K_{LL} K LL = live load element factor:
K L L = 4 K_{LL} = 4 K LL = 4 for interior columns and exterior columns without cantilever slabs.
K L L = 2 K_{LL} = 2 K LL = 2 for interior beams and exterior beams without cantilevers.
K L L = 1 K_{LL} = 1 K LL = 1 for two-way slabs.
Absolute Reduction Limits:
The reduction factor ( 0.25 + 4.57 A I ) \left(0.25 + \frac{4.57}{\sqrt{A_I}}\right) ( 0.25 + A I 4.57 ) shall not be less than 0.50 0.50 0.50 for members supporting one floor ( L ≥ 0.50 L 0 L \ge 0.50 L_0 L ≥ 0.50 L 0 ).
The reduction factor shall not be less than 0.40 0.40 0.40 for members supporting two or more floors ( L ≥ 0.40 L 0 L \ge 0.40 L_0 L ≥ 0.40 L 0 ).
Ineligibility: Live loads exceeding 4.8 kPa 4.8\text{ kPa} 4.8 kPa shall not be reduced, except that members supporting two or more floors may have their live loads reduced by up to 20 % 20\% 20% . Areas intended for public assembly and parking garages cannot be reduced.
- 3. Basic Load Combinations (NSCP Section 203)
- Strength Design / Ultimate Strength Design (USD / LRFD)
Under Strength Design, structural members must resist the most critical factored load combination:
U = 1.4 D U = 1.4 D U = 1.4 D
U = 1.2 D + 1.6 L + 0.5 ( L r or R ) U = 1.2 D + 1.6 L + 0.5 (L_r \text{ or } R) U = 1.2 D + 1.6 L + 0.5 ( L r or R )
U = 1.2 D + 1.6 ( L r or R ) + ( 1.0 L or 0.5 W ) U = 1.2 D + 1.6 (L_r \text{ or } R) + (1.0 L \text{ or } 0.5 W) U = 1.2 D + 1.6 ( L r or R ) + ( 1.0 L or 0.5 W )
U = 1.2 D + 1.0 W + 1.0 L + 0.5 ( L r or R ) U = 1.2 D + 1.0 W + 1.0 L + 0.5 (L_r \text{ or } R) U = 1.2 D + 1.0 W + 1.0 L + 0.5 ( L r or R )
- U = 1.2 D + 1.0 E + 1.0 L U = 1.2 D + 1.0 E + 1.0 L U = 1.2 D + 1.0 E + 1.0 L
- U = 0.9 D + 1.0 W U = 0.9 D + 1.0 W U = 0.9 D + 1.0 W
- U = 0.9 D + 1.0 E U = 0.9 D + 1.0 E U = 0.9 D + 1.0 E
Note on Seismic Combinations: The load combinations 0.9 D + 1.0 E 0.9D + 1.0E 0.9 D + 1.0 E and 0.9 D + 1.0 W 0.9D + 1.0W 0.9 D + 1.0 W govern foundation uplift and member overturning where dead load resists lateral overturning. For combination 5, the live load factor may be reduced to 0.5 L 0.5 L 0.5 L for occupancies where L 0 ≤ 4.8 kPa L_0 \le 4.8\text{ kPa} L 0 ≤ 4.8 kPa , except for garages and public assembly.
- Allowable Stress Design (ASD) Alternative
- D D D
- D + L D + L D + L
- D + ( L r or R ) D + (L_r \text{ or } R) D + ( L r or R )
- D + 0.75 L + 0.75 ( L r or R ) D + 0.75 L + 0.75 (L_r \text{ or } R) D + 0.75 L + 0.75 ( L r or R )
- D + ( 0.6 W or E / 1.4 ) D + (0.6 W \text{ or } E/1.4) D + ( 0.6 W or E /1.4 )
- 0.6 D + ( 0.6 W or E / 1.4 ) 0.6 D + (0.6 W \text{ or } E/1.4) 0.6 D + ( 0.6 W or E /1.4 )
- 4. Wind Loads: MWFRS (NSCP Section 207)
The Philippines experiences the highest frequency of destructive tropical cyclones in the world. Wind load calculations reflect 3-second gust wind speeds at 10 m 10\text{ m} 10 m above ground level in Exposure C.
Basic Wind Speed Maps ( V V V )
NSCP 2015 replaced the older three-zone wind map of NSCP 2010 with wind-speed contour maps , Figures 207A.5-1A to 207A.5-1C. Separate maps cover different occupancy categories. The speeds are nominal 3-second gusts at 10 m 10\text{ m} 10 m in Exposure C, derived from PAGASA data. Linear interpolation between contours is allowed, and coastal sites take the last contour.
Speeds are highest on the typhoon-exposed Pacific seaboard (eastern Luzon, Bicol, Eastern Visayas) and decrease toward the west and southwest.
Higher occupancy categories, such as essential facilities, use the map with longer return periods and therefore higher speeds.
Convert to m/s before using the velocity pressure equation: V [ m/s ] = V [ km/h ] / 3.6 V\,[\text{m/s}] = V\,[\text{km/h}] / 3.6 V [ m/s ] = V [ km/h ] /3.6 .
Terrain Exposure Categories
Exposure B: Urban and suburban areas, wooded areas, or other terrain with numerous closely spaced obstructions having the size of single-family dwellings or larger ( z g = 365.76 m z_g = 365.76\text{ m} z g = 365.76 m , α = 7.0 \alpha = 7.0 α = 7.0 ).
Exposure C: Open terrain with scattered obstructions having heights generally less than 9 m 9\text{ m} 9 m , including flat open country and grasslands ( z g = 274.32 m z_g = 274.32\text{ m} z g = 274.32 m , α = 9.5 \alpha = 9.5 α = 9.5 ).
Exposure D: Flat, unobstructed areas and water surfaces, including smooth salt flats and coastal shorelines in hurricane-prone regions ( z g = 213.36 m z_g = 213.36\text{ m} z g = 213.36 m , α = 11.5 \alpha = 11.5 α = 11.5 ).
Velocity Pressure Equation
q z = 0.613 K z K z t K d V 2 ( N/m 2 ) q_z = 0.613 K_z K_{zt} K_d V^2 \quad (\text{N/m}^2) q z = 0.613 K z K z t K d V 2 ( N/m 2 )
Where:
V V V = basic wind speed in meters per second ( m/s \text{m/s} m/s ).
K z K_z K z = velocity pressure exposure coefficient evaluated at height z z z .
K z t K_{zt} K z t = topographic factor (accounting for wind speed-up over isolated hills, ridges, or escarpments; K z t = 1.0 K_{zt} = 1.0 K z t = 1.0 for level ground).
K d K_d K d = wind directionality factor ( K d = 0.85 K_d = 0.85 K d = 0.85 for Main Wind-Force Resisting Systems and Components/Cladding).
Design Wind Pressure for MWFRS
For rigid enclosed buildings:
p = q G C p − q i ( G C p i ) p = q G C_p - q_i (G C_{pi}) p = qG C p − q i ( G C p i )
where q = q z q = q_z q = q z for windward walls and q h q_h q h for leeward walls, G = 0.85 G = 0.85 G = 0.85 is the gust effect factor, C p = + 0.8 C_p = +0.8 C p = + 0.8 for windward walls and − 0.5 -0.5 − 0.5 to − 0.2 -0.2 − 0.2 for leeward walls, and ( G C p i ) = ± 0.18 (G C_{pi}) = \pm 0.18 ( G C p i ) = ± 0.18 is the internal pressure coefficient for enclosed buildings ( ± 0.55 \pm 0.55 ± 0.55 for partially enclosed buildings).
5. Earthquake / Seismic Loads: Equivalent Lateral Force Procedure (NSCP Section 208)
The Equivalent Lateral Force (ELF) static procedure models dynamic ground motions as equivalent static horizontal lateral forces applied at each floor level.
- Design Total Seismic Base Shear ( V V V )
- V = C v I R T W V = \frac{C_v I}{R T} W V = RT C v I W
Upper Bound Limit (Governs for short-period / stiff structures):
V ≤ 2.5 C a I R W V \le \frac{2.5 C_a I}{R} W V ≤ R 2.5 C a I W
Lower Bound Limits:
- For all seismic zones: V ≥ 0.11 C a I W V \ge 0.11 C_a I W V ≥ 0.11 C a I W
- In addition, for Seismic Zone 4 : V ≥ 0.8 Z N v I R W V \ge \frac{0.8 Z N_v I}{R} W V ≥ R 0.8 Z N v I W
Where:
W W W = total seismic dead weight of the structure (plus 25 % 25\% 25% of floor live load for storage occupancies, plus partition allowance of 1.0 kPa 1.0\text{ kPa} 1.0 kPa ).
T T T = fundamental natural period of the building in seconds (Method A: T = C t ( h n ) 3 / 4 T = C_t (h_n)^{3/4} T = C t ( h n ) 3/4 , with C t = 0.0731 C_t = 0.0731 C t = 0.0731 for RC moment frames, 0.0853 0.0853 0.0853 for steel moment frames).
I I I = Seismic Importance Factor:
- Essential Facilities (Hospitals, Emergency response, Power stations): I = 1.50 I = 1.50 I = 1.50
- Hazardous Facilities: I = 1.25 I = 1.25 I = 1.25
- Special Occupancy (Schools, Assembly > 300 >300 > 300 persons): I = 1.00 I = 1.00 I = 1.00
- Standard Occupancy (Residential, Commercial): I = 1.00 I = 1.00 I = 1.00
R R R = Response Modification Factor (ductility capacity):
- Reinforced Concrete Special Moment Resisting Frame (RC SMRF): R = 8.5 R = 8.5 R = 8.5
- RC Intermediate Moment Resisting Frame (RC IMRF): R = 5.5 R = 5.5 R = 5.5
- RC Ordinary Moment Resisting Frame (RC OMRF): R = 3.5 R = 3.5 R = 3.5
- Concrete Shear Walls in a Building Frame System: R = 5.5 R = 5.5 R = 5.5
- Seismic Zone Factor ( Z Z Z )
Zone 4 ( Z = 0.40 Z = 0.40 Z = 0.40 ): Entire Philippine archipelago except Zone 2.
Zone 2 ( Z = 0.20 Z = 0.20 Z = 0.20 ): Palawan (except Busuanga), Sulu, and Tawi-Tawi .
(Note: There are no Zone 1 or Zone 3 designations in NSCP 2015).
- Soil Profile Types ( S A S_A S A through S F S_F S F )
- S A S_A S A : Hard rock ( v s > 1500 m/s v_s > 1500\text{ m/s} v s > 1500 m/s )
- S B S_B S B : Rock ( 760 < v s ≤ 1500 m/s 760 < v_s \le 1500\text{ m/s} 760 < v s ≤ 1500 m/s )
S C S_C S C : Very dense soil and soft rock ( 360 < v s ≤ 760 m/s 360 < v_s \le 760\text{ m/s} 360 < v s ≤ 760 m/s )
S D S_D S D : Stiff soil profile ( 180 ≤ v s ≤ 360 m/s 180 \le v_s \le 360\text{ m/s} 180 ≤ v s ≤ 360 m/s )
S E S_E S E : Soft soil profile ( v s < 180 m/s v_s < 180\text{ m/s} v s < 180 m/s )
S F S_F S F : Soil requiring site-specific evaluation (liquefiable soils, collapsible soils, highly sensitive clays).
Near-Source Factors ( N a N_a N a and N v N_v N v )
Near-source factors account for localized velocity pulses and high-frequency ground motion amplification within close proximity to active fault lines (Seismic Source Types A, B, C):
For distance ≤ 2.0 km \le 2.0\text{ km} ≤ 2.0 km to an active Type A fault: N a N_a N a reaches up to 1.50 1.50 1.50 and N v N_v N v reaches up to 2.00 2.00 2.00 .
For distance ≥ 15.0 km \ge 15.0\text{ km} ≥ 15.0 km : N a = 1.00 N_a = 1.00 N a = 1.00 and N v = 1.00 N_v = 1.00 N v = 1.00 .
Vertical Distribution of Seismic Base Shear
The base shear V V V is distributed across the building height:
If the fundamental period exceeds 0.7 seconds 0.7\text{ seconds} 0.7 seconds ( T > 0.7 s T > 0.7\text{ s} T > 0.7 s ), a concentrated top force F t F_t F t is assigned to the roof level to account for higher-mode whiplash effects: F t = 0.07 T V ≤ 0.25 V F_t = 0.07 T V \le 0.25 V F t = 0.07 T V ≤ 0.25 V
If T ≤ 0.7 s T \le 0.7\text{ s} T ≤ 0.7 s , F t = 0 F_t = 0 F t = 0 .
The remaining shear force ( V − F t ) (V - F_t) ( V − F t ) is distributed to each floor level x x x :
F x = ( V − F t ) w x h x ∑ i = 1 n w i h i F_x = \frac{(V - F_t) w_x h_x}{\sum_{i=1}^n w_i h_i} F x = ∑ i = 1 n w i h i ( V − F t ) w x h x
- 6. Comprehensive Worked Example
- Worked Example: Seismic Base Shear of an Office Building in Manila
Problem: A 5-story reinforced concrete Special Moment Resisting Frame (SMRF, R = 8.5 R = 8.5 R = 8.5 ) office building is to be constructed in Quezon City (Seismic Zone 4, Z = 0.40 Z = 0.40 Z = 0.40 ).
Site Data: Soil Profile Type S D S_D S D (Stiff soil). The site is located 18.0 km 18.0\text{ km} 18.0 km from the West Valley Fault ( N a = 1.0 N_a = 1.0 N a = 1.0 , N v = 1.0 N_v = 1.0 N v = 1.0 ).
Occupancy: Standard Office ( I = 1.0 I = 1.0 I = 1.0 ).
Building Height: Total height h n = 17.5 m h_n = 17.5\text{ m} h n = 17.5 m ( 3.5 m 3.5\text{ m} 3.5 m per story).
Seismic Weight: Total dead weight W = 12 , 000 kN W = 12,000\text{ kN} W = 12 , 000 kN ( 2 , 400 kN 2,400\text{ kN} 2 , 400 kN at each floor level).
Seismic Coefficients: From NSCP 2015 tables for Z = 0.40 Z = 0.40 Z = 0.40 and Soil S D S_D S D : C a = 0.44 N a = 0.44 C_a = 0.44 N_a = 0.44 C a = 0.44 N a = 0.44 , C v = 0.64 N v = 0.64 C_v = 0.64 N_v = 0.64 C v = 0.64 N v = 0.64 .
Determine: (a) fundamental period T T T , (b) design base shear V V V , and (c) vertical distribution of lateral forces.
Solution:
Step 1: Fundamental Period T T T (Method A): For reinforced concrete moment frames: T = C t ( h n ) 3 / 4 = 0.0731 ( 17.5 ) 3 / 4 = 0.0731 × 8.567 = 0.626 s T = C_t (h_n)^{3/4} = 0.0731 (17.5)^{3/4} = 0.0731 \times 8.567 = 0.626\text{ s} T = C t ( h n ) 3/4 = 0.0731 ( 17.5 ) 3/4 = 0.0731 × 8.567 = 0.626 s
Step 2: Calculate Base Shear from Period Formula: V = C v I R T W = 0.64 × 1.0 8.5 × 0.626 × 12 , 000 = 0.64 5.321 × 12 , 000 = 0.1203 × 12 , 000 = 1443.3 kN V = \frac{C_v I}{R T} W = \frac{0.64 \times 1.0}{8.5 \times 0.626} \times 12,000 = \frac{0.64}{5.321} \times 12,000 = 0.1203 \times 12,000 = 1443.3\text{ kN} V = RT C v I W = 8.5 × 0.626 0.64 × 1.0 × 12 , 000 = 5.321 0.64 × 12 , 000 = 0.1203 × 12 , 000 = 1443.3 kN
Step 3: Check Governing Upper Limit: V max = 2.5 C a I R W = 2.5 × 0.44 × 1.0 8.5 × 12 , 000 = 1.10 8.5 × 12 , 000 = 0.1294 × 12 , 000 = 1552.9 kN V_{\text{max}} = \frac{2.5 C_a I}{R} W = \frac{2.5 \times 0.44 \times 1.0}{8.5} \times 12,000 = \frac{1.10}{8.5} \times 12,000 = 0.1294 \times 12,000 = 1552.9\text{ kN} V max = R 2.5 C a I W = 8.5 2.5 × 0.44 × 1.0 × 12 , 000 = 8.5 1.10 × 12 , 000 = 0.1294 × 12 , 000 = 1552.9 kN Since V period = 1443.3 kN ≤ 1552.9 kN V_{\text{period}} = 1443.3\text{ kN} \le 1552.9\text{ kN} V period = 1443.3 kN ≤ 1552.9 kN , the period formula governs.
Step 4: Check Lower Limits:
Minimum Limit 1: V min1 = 0.11 C a I W = 0.11 × 0.44 × 1.0 × 12 , 000 = 580.8 kN V_{\text{min1}} = 0.11 C_a I W = 0.11 \times 0.44 \times 1.0 \times 12,000 = 580.8\text{ kN} V min1 = 0.11 C a I W = 0.11 × 0.44 × 1.0 × 12 , 000 = 580.8 kN
Minimum Limit 2 (Zone 4): V min2 = 0.8 Z N v I R W = 0.8 × 0.40 × 1.0 × 1.0 8.5 × 12 , 000 = 0.32 8.5 × 12 , 000 = 451.8 kN V_{\text{min2}} = \frac{0.8 Z N_v I}{R} W = \frac{0.8 \times 0.40 \times 1.0 \times 1.0}{8.5} \times 12,000 = \frac{0.32}{8.5} \times 12,000 = 451.8\text{ kN} V min2 = R 0.8 Z N v I W = 8.5 0.8 × 0.40 × 1.0 × 1.0 × 12 , 000 = 8.5 0.32 × 12 , 000 = 451.8 kN Since V = 1443.3 kN V = 1443.3\text{ kN} V = 1443.3 kN is strictly greater than both lower limits ( 1443.3 > 580.8 1443.3 > 580.8 1443.3 > 580.8 and 1443.3 > 451.8 1443.3 > 451.8 1443.3 > 451.8 ), the design base shear is V = 1443.3 kN V = 1443.3\text{ kN} V = 1443.3 kN .
Step 5: Vertical Force Distribution: Because T = 0.626 s ≤ 0.70 s T = 0.626\text{ s} \le 0.70\text{ s} T = 0.626 s ≤ 0.70 s , the top concentrated force is zero: F t = 0 F_t = 0 F t = 0 .
The lateral force is distributed proportionally to w x h x w_x h_x w x h x :
Level h x h_x h x (m) w x w_x w x (kN) w x h x w_x h_x w x h x (kN·m) Fraction w x h x ∑ w i h i \frac{w_x h_x}{\sum w_i h_i} ∑ w i h i w x h x Lateral Force F x F_x F x (kN)
Roof (5) 17.5 2,400 42,000 42 , 000 / 126 , 000 = 0.3333 42,000 / 126,000 = 0.3333 42 , 000/126 , 000 = 0.3333 481.1
4th Floor 14.0 2,400 33,600 33 , 600 / 126 , 000 = 0.2667 33,600 / 126,000 = 0.2667 33 , 600/126 , 000 = 0.2667 384.9
3rd Floor 10.5 2,400 25,200 25 , 200 / 126 , 000 = 0.2000 25,200 / 126,000 = 0.2000 25 , 200/126 , 000 = 0.2000 288.7
2nd Floor 7.0 2,400 16,800 16 , 800 / 126 , 000 = 0.1333 16,800 / 126,000 = 0.1333 16 , 800/126 , 000 = 0.1333 192.4
1st Floor 3.5 2,400 8,400 8 , 400 / 126 , 000 = 0.0667 8,400 / 126,000 = 0.0667 8 , 400/126 , 000 = 0.0667 96.2
Total — 12,000 126,000 1.0000 1,443.3 kN
Check: ∑ F x = 481.1 + 384.9 + 288.7 + 192.4 + 96.2 = 1443.3 kN = V \sum F_x = 481.1 + 384.9 + 288.7 + 192.4 + 96.2 = 1443.3\text{ kN} = V ∑ F x = 481.1 + 384.9 + 288.7 + 192.4 + 96.2 = 1443.3 kN = V .
7. Licensure Exam Pitfalls & Review Notes
Warning
Pitfall 1: Seismic Zonation of Palawan and Tawi-Tawi The Philippines contains only Zone 2 ( Z = 0.20 Z = 0.20 Z = 0.20 ) and Zone 4 ( Z = 0.40 Z = 0.40 Z = 0.40 ). There are no Zone 1 or Zone 3 classifications in NSCP 2015. Palawan (except Busuanga), Sulu, and Tawi-Tawi are Zone 2; the rest of the archipelago is Zone 4.
Caution
Pitfall 2: Neglecting the Seismic Base Shear Upper Bound For short-period structures (typically low-rise buildings with T < T s = C v / 2.5 C a T < T_s = C_v / 2.5 C_a T < T s = C v /2.5 C a ), the period formula C v I R T W \frac{C_v I}{RT} W RT C v I W yields excessively high, unrealistic shears. The code mandates that V V V need not exceed 2.5 C a I R W \frac{2.5 C_a I}{R} W R 2.5 C a I W . Always evaluate the upper limit!
Tip
Pitfall 3: Live Load Influence Area ( A I A_I A I ) vs. Tributary Area ( A T A_T A T ) In the live load reduction formula L = L 0 [ 0.25 + 4.57 / A I ] L = L_0 [0.25 + 4.57/\sqrt{A_I}] L = L 0 [ 0.25 + 4.57/ A I ] , you must use the influence area A I = K L L A T A_I = K_{LL} A_T A I = K LL A T , NOT the tributary area A T A_T A T directly. For an interior column, K L L = 4 K_{LL} = 4 K LL = 4 , making A I A_I A I four times larger than A T A_T A T .