Study guide
15.3 Timber Design Principles, Working Stress, and Sawn Lumber Beams
PRC Civil Engineer Licensure Examination CELE
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Examination Overview, RA 544 & Professional Practice
1.1 CELE Structure, Format, Scoring, and 2026 Subject Order 1.2 Republic Act No. 544: The Civil Engineering Law and Board Regulations 1.3 Civil Engineering Ethics, Contracts, and Professional Practice
2 Chapter 2: Engineering Mathematics, Numerical Methods & Physics
2.1 Advanced Algebra, Progressions & Word Problems 2.2 Trigonometry and Analytical Geometry 2.3 Differential and Integral Calculus 2.4 Differential Equations and Numerical Methods 2.5 Series, Hyperbolic Functions, Multivariable Calculus, and Laplace Transforms 2.6 Numerical Methods: Linear Systems, Interpolation, Curve Fitting, and ODE Solvers 2.7 Physics for Engineers: Kinematics, Newton's Laws, Work-Energy, and Momentum
3 Chapter 3: Engineering Data Analysis & Engineering Economy
3.1 Engineering Data Analysis and Statistical Applications 3.2 Parameter Estimation, Linear Regression, Correlation, and Queuing Models 3.3 Engineering Economy: Time Value of Money and Interest Formulas 3.4 Project Evaluation, Depreciation, and Benefit-Cost Analysis
4 Chapter 4: Surveying Fundamentals, Construction Layout & Route Surveying
4.1 Errors, Corrections, and Pacing/Taping 4.2 Leveling, Earthworks, and Mass Haul Diagrams 4.3 Traverse Computations, Balancing, and Area Determinations 4.4 Route Surveying: Horizontal and Vertical Curves
5 Chapter 5: Highway & Transportation Engineering
5.1 Highway Geometric Design and Sight Distances 5.2 Traffic Engineering, Flow Fundamentals, and Pavement Design 5.3 Highway Policy, Route Location, Drainage, and Earthwork Slopes 5.4 Transportation Planning, Network Analysis, and Intermodal Systems
6 Chapter 6: Construction Materials, Methods, Management & Safety
6.1 Materials for Construction: Concrete, Formwork, Masonry, Steel, and Wood Products 6.2 Construction Equipment, Formwork, and Construction Methods 6.3 Construction Occupational Safety and Health: RA 11058 and DOLE DO 13 6.4 Construction Project Management, CPM/PERT, and Resource Scheduling 6.5 Construction Principles: Design Requirements, Project Organization, Cost Control, and Value Engineering 6.6 Quantity Surveying, Unit Cost Analysis, and Project Cost Estimates 6.7 Construction Trades and Specialties: Plumbing, Plastics, Doors and Windows, Finishes, and Electrical
7 Chapter 7: Fluid Properties, Hydrostatics & Buoyancy
7.1 Fluid Properties, Units, and Pressure Measurement 7.2 Hydrostatic Pressure on Plane and Curved Surfaces 7.3 Buoyancy, Flotation, and Accelerated Fluid Masses
8 Chapter 8: Hydrodynamics, Pipe Flow, Open Channels & Water Supply
8.1 Fluid Dynamics: Continuity and Energy Equations 8.2 Flow Measurement: Orifices, Weirs, and Venturi Meters 8.3 Fluid Flow in Pipes, Friction Losses, and Pipe Networks 8.4 Open Channel Flow, Manning's Equation, and Hydraulic Jump 8.5 Water Supply: Demand, Storage, Pumping, Distribution, and Treatment
9 Chapter 9: Soil Properties, Seepage & Stresses in Soil Mass
9.1 Soil Composition, Weight-Volume Phase Relationships 9.2 Soil Classification Systems (USCS & AASHTO) and Atterberg Limits 9.3 Soil Permeability, Seepage, Flow Nets, and Effective Stress 9.4 Stresses in Soil Mass, Stress Distribution, and Immediate and Secondary Settlement
10 Chapter 10: Consolidation, Soil Strength, Earth Pressures & Foundations
10.1 Soil Compaction and Soil Compressibility/Consolidation 10.2 Shear Strength of Soils and Mohr-Coulomb Failure Criteria 10.3 Lateral Earth Pressures (Rankine & Coulomb) and Retaining Walls 10.4 Shallow and Deep Foundation Bearing Capacity and Slope Stability
11 Chapter 11: Engineering Mechanics & Statics
11.1 Force Systems, Resultants, and Equilibrium of Rigid Bodies 11.2 Centroids, Moments of Inertia, and Friction 11.3 Cables, Trusses, and Internal Forces in Members
12 Chapter 12: Strength of Materials
12.1 Axial Stress, Strain, and Deformation 12.2 Torsion, Flanged Bolt Couplings, and Thin-Walled Pressure Vessels 12.3 Beam Stresses: Flexural and Transverse Shear 12.4 Beam Deflections, Combined Stresses, and Mohr's Circle
13 Chapter 13: Structural Analysis & NSCP Load Criteria
13.1 Indeterminate Structures: Approximate and Classical Methods 13.2 Moment Distribution Method and Slope Deflection 13.3 Influence Lines for Determinate and Indeterminate Structures 13.4 NSCP Minimum Design Loads: Dead, Live, Wind, and Earthquake
14 Chapter 14: Reinforced Concrete Design (NSCP 2015 / USD)
14.1 Ultimate Strength Design (USD) Principles and Singly Reinforced Beams 14.2 Doubly Reinforced Beams and T-Beams 14.3 Shear and Diagonal Tension, Stirrup Design, and Development Length 14.4 Reinforced Concrete Columns and Isolated Footing Design
15 Chapter 15: Steel, Timber & Prestressed Design and Materials Testing
15.1 Structural Steel Tension Members and Connections 15.2 Structural Steel Compression Members and Beam Design 15.3 Timber Design Principles, Working Stress, and Sawn Lumber Beams 15.4 Prestressed Concrete Fundamentals and Prestress Losses 15.5 Construction Materials Testing and Concrete Mix Proportioning
15.3 Timber Design Principles, Working Stress, and Sawn Lumber Beams
Key Takeaways Explain This Topic AI
Wood is a highly anisotropic, cellular organic material exhibiting dramatically higher tensile and compressive strength parallel to the grain than perpendicular to the grain (Fc ≫ Fc⊥, Ft ≫ Ft⊥).
Allowable Stress Design (ASD / Working Stress Design) governs Philippine timber design under NSCP 2015 Chapter 6, where allowable stresses equal base reference values multiplied by adjustment factors (F' = F × CD × CM × Ct × CF ...).
The load duration factor CD accounts for timber's rheological strength under sustained load, ranging from 0.90 for permanent dead load, 1.0 for normal 10-year occupancy loads, up to 1.60 for short-duration earthquake and wind forces.
For rectangular sawn lumber beams, maximum horizontal shear stress occurs at the neutral axis and is calculated as fv = 1.5 V / (bd) ≤ F'v, with the critical design shear evaluated at distance d from the support face.
Solid timber column capacity is controlled by the slenderness ratio le / d ≤ 50 and the column stability factor CP, calculated using the Ylinen equation to account for combined material yielding and elastic buckling.
Last updated: October 2026
15.3 Timber Design Principles, Working Stress, and Sawn Lumber Beams
Timber is one of the oldest and most versatile construction materials in the Philippines. As an organic cellular polymer formed by the biological growth of trees, wood possesses unique structural characteristics that distinguish it fundamentally from isotropic materials like structural steel and concrete. Wood is orthotropic (anisotropic)—its mechanical strength, stiffness, shrinkage, and thermal expansion differ across three mutually perpendicular axes: longitudinal (parallel to grain), radial (perpendicular to growth rings), and tangential (tangent to growth rings).
In Philippine civil engineering practice and licensure examinations, structural timber is designed strictly under the Working Stress Design (WSD) / Allowable Stress Design (ASD) methodology codified in NSCP 2015 Chapter 6 (derived from the National Design Specification for Wood Construction - NDS).
1. Wood Anisotropy and Grain Orientation
Because wood fibers (tracheids in softwoods, vessels and fibers in hardwoods) are oriented along the trunk axis, wood exhibits maximum strength and stiffness parallel to the grain :
Compression Parallel to Grain ( F c F_c F c ): Wood cells act as hollow micro-tubular columns that resist compressive forces efficiently until cell wall buckling occurs ( F c ≈ 20 − 45 MPa F_c \approx 20 - 45\text{ MPa} F c ≈ 20 − 45 MPa for Philippine hardwoods).
Compression Perpendicular to Grain ( F c ⊥ F_{c\perp} F c ⊥ ): Compressive loads crush the hollow tubular cells transversely. Elastic deformation is small; failure occurs by progressive cell wall flattening at allowable stresses only 20 % − 30 % 20\% - 30\% 20% − 30% of parallel compression ( F c ⊥ ≈ 4 − 10 MPa F_{c\perp} \approx 4 - 10\text{ MPa} F c ⊥ ≈ 4 − 10 MPa ).
Tension Parallel to Grain ( F t F_t F t ): Extremely high ultimate capacity, but governed in service by slope of grain, knots, and splits.
Tension Perpendicular to Grain ( F t ⊥ F_{t\perp} F t ⊥ ): Tensile loads pull wood fibers apart laterally. Capacity is extremely low and unpredictable ( < 1.0 MPa < 1.0\text{ MPa} < 1.0 MPa ). Designs that induce tension perpendicular to the grain should be avoided wherever possible.
Shear Parallel to Grain ( F v F_v F v ): Also known as horizontal shear , this limit state governs flexural beams. Shear stresses attempt to slide horizontal wood fibers past one another ( F v ≈ 1.5 − 3.5 MPa F_v \approx 1.5 - 3.5\text{ MPa} F v ≈ 1.5 − 3.5 MPa ).
Moisture Content and Fiber Saturation Point
Wood is hygroscopic, exchanging water vapor with the atmosphere. Water exists in two states: free water in cell cavities and bound water within cell walls. When all free water has evaporated while cell walls remain fully saturated, the wood is at the Fiber Saturation Point (FSP) (typically 25 % − 30 % 25\% - 30\% 25% − 30% moisture content). Above FSP, changes in moisture content do not affect mechanical strength. Below FSP, drying strengthens the wood cells and causes shrinkage. Lumber is classified as dry / seasoned when moisture content is ≤ 19 % \le 19\% ≤ 19% , and green / unseasoned when > 19 % > 19\% > 19% .
2. Philippine Timber Classifications (NSCP / FPRDI)
NSCP Chapter 6 tabulates allowable stresses and moduli species by species for Philippine woods, based on research by the Forest Products Research and Development Institute (FPRDI). Values differ by species, moisture condition and stress grade, so board problems almost always state the values to use. For orientation, common structural species fall roughly into three groups:
Relative strength Representative Philippine species Typical use
High (dense, durable hardwoods) Yakal, Guijo, Molave, Ipil, Narra Heavy framing, exposed members, marine and bridge timbers
- Moderate Apitong, Tangile, Red and White Lauan Trusses, purlins, joists, formwork
- Lower (light hardwoods and pine) Almon, Mayapis, Bagtikan, Benguet pine Light framing, interior work
The worked examples below use stated allowable stresses as given data. Use the NSCP table values for the species and grade specified in an actual design.
Note: Yakal and Guijo are widely specified in coastal bridges and wharf structures for high decay resistance, while Apitong and Lauan are standard for roof trusses, purlins, and floor framing.
3. Working Stress Design Adjustment Factors
Reference design values ( F F F ) obtained from testing standardized defect-free specimens must be modified by environmental, geometric, and loading condition factors to determine the adjusted allowable design value ( F ′ F' F ′ ) :
F ′ = F ⋅ ∏ C i = F ⋅ C D ⋅ C M ⋅ C t ⋅ C L ⋅ C F ⋅ C f u ⋅ C r F' = F \cdot \prod C_i = F \cdot C_D \cdot C_M \cdot C_t \cdot C_L \cdot C_F \cdot C_{fu} \cdot C_r F ′ = F ⋅ ∏ C i = F ⋅ C D ⋅ C M ⋅ C t ⋅ C L ⋅ C F ⋅ C f u ⋅ C r
1. Load Duration Factor ( C D C_D C D )
Wood exhibits viscoelastic rheological behavior: it can sustain higher stresses for short time durations than for long durations. Reference design stresses are calibrated to a normal cumulative duration of 10 years ( C D = 1.00 C_D = 1.00 C D = 1.00 ). The load duration factor applies to all strength properties ( F b , F t , F c , F v F_b, F_t, F_c, F_v F b , F t , F c , F v ), but never to modulus of elasticity ( E E E ) or compression perpendicular to grain ( F c ⊥ F_{c\perp} F c ⊥ ):
- Load Duration Governing Design Load Type C D C_D C D Value
- Permanent Over 10 years (Dead load only) 0.90 0.90 0.90
- Normal (10 Years) Occupancy live load 1.00 1.00 1.00
- 2 Months Snow load (temperate) / storage live load 1.15 1.15 1.15
- 7 Days Construction loads / roof live load 1.25 1.25 1.25
- 10 Minutes Wind or Earthquake lateral forces 1.60 1.60 1.60 (or 1.33 1.33 1.33 in older codes)
- Instantaneous Impact load 2.00 2.00 2.00
- 2. Wet Service Factor ( C M C_M C M )
Applies when structural lumber is exposed to outdoor weathering or high humidity where moisture content exceeds 19 % 19\% 19% . For sawn lumber, C M = 0.85 C_M = 0.85 C M = 0.85 for flexure ( F b F_b F b ), C M = 0.80 C_M = 0.80 C M = 0.80 for compression parallel ( F c F_c F c ), and C M = 0.90 C_M = 0.90 C M = 0.90 for modulus of elasticity ( E E E ).
3. Size Factor ( C F C_F C F )
Accounts for the volume effect: larger timber beams have a higher statistical probability of containing critical grain flaws. For visually graded sawn lumber dimension sizes ( d > 300 mm d > 300\text{ mm} d > 300 mm or 12 in 12\text{ in} 12 in ):
- C F = ( 300 d ) 1 / 9 C_F = \left( \frac{300}{d} \right)^{1/9} C F = ( d 300 ) 1/9
- 4. Repetitive Member Factor ( C r = 1.15 C_r = 1.15 C r = 1.15 )
When three or more parallel sawn lumber members (such as floor joists, roof rafters, or purlins) are spaced not more than 600 mm 600\text{ mm} 600 mm ( 24 in 24\text{ in} 24 in ) on center and joined by sheathing that transfers load transverse to the members, load sharing prevents individual member overload. An allowable bending stress increase of 15 % 15\% 15% ( C r = 1.15 C_r = 1.15 C r = 1.15 ) is permitted.
5. Flat Use Factor ( C f u C_{fu} C f u )
When rectangular sawn lumber is loaded on its wide face ( d < b d < b d < b , flatwise bending), fiber stress is redistributed more favorably, yielding C f u > 1.0 C_{fu} > 1.0 C f u > 1.0 ( 1.10 − 1.22 1.10 - 1.22 1.10 − 1.22 ).
- 4. Sawn Lumber Beam Design (Flexure and Horizontal Shear)
- Flexural Strength Verification
For a rectangular sawn lumber beam of actual width b b b and depth d d d , the section modulus is S = b d 2 6 S = \frac{b d^2}{6} S = 6 b d 2 . The actual bending stress ( f b f_b f b ) must not exceed the adjusted allowable bending stress ( F b ′ F'_b F b ′ ):
f b = M S = 6 M b d 2 ≤ F b ′ = F b ⋅ C D ⋅ C M ⋅ C t ⋅ C L ⋅ C F ⋅ C r f_b = \frac{M}{S} = \frac{6 M}{b d^2} \le F'_b = F_b \cdot C_D \cdot C_M \cdot C_t \cdot C_L \cdot C_F \cdot C_r f b = S M = b d 2 6 M ≤ F b ′ = F b ⋅ C D ⋅ C M ⋅ C t ⋅ C L ⋅ C F ⋅ C r
Horizontal Shear Stress in Rectangular Beams
From the mechanics of materials, the horizontal shear stress at distance y y y from the neutral axis is f v = V Q I b f_v = \frac{V Q}{I b} f v = I b V Q . For a homogeneous solid rectangular cross-section, maximum shear occurs at the neutral axis ( Q max = b d 2 8 Q_{\max} = \frac{b d^2}{8} Q m a x = 8 b d 2 , I = b d 3 12 I = \frac{b d^3}{12} I = 12 b d 3 ):
f v , max = V ( b d 2 8 ) ( b d 3 12 ) b = 3 V 2 b d = 1.5 V A ≤ F v ′ f_{v,\max} = \frac{V \left(\frac{b d^2}{8}\right)}{\left(\frac{b d^3}{12}\right) b} = \frac{3 V}{2 b d} = 1.5 \frac{V}{A} \le F'_v f v , m a x = ( 12 b d 3 ) b V ( 8 b d 2 ) = 2 b d 3 V = 1.5 A V ≤ F v ′
Critical Shear Reduction ( d d d -Distance Rule)
Because loads near a support are carried directly into the bearing by compression, NSCP Chapter 6 (following the NDS) permits neglecting uniformly distributed loads within a distance equal to the beam depth ( d d d ) from the face of the support when calculating the design shear force V V V . For a uniformly distributed load w w w on a simple span L L L :
V design = R − w ⋅ d = w L 2 − w d V_{\text{design}} = R - w \cdot d = \frac{w L}{2} - w d V design = R − w ⋅ d = 2 w L − w d
Bearing Stress Perpendicular to Grain
At beam supports, the reaction force R R R induces compressive bearing perpendicular to wood fibers over bearing area A b = b ⋅ l b A_b = b \cdot l_b A b = b ⋅ l b :
f c ⊥ = R b ⋅ l b ≤ F c ⊥ ′ = F c ⊥ ⋅ C M ⋅ C t ⋅ C b f_{c\perp} = \frac{R}{b \cdot l_b} \le F'_{c\perp} = F_{c\perp} \cdot C_M \cdot C_t \cdot C_b f c ⊥ = b ⋅ l b R ≤ F c ⊥ ′ = F c ⊥ ⋅ C M ⋅ C t ⋅ C b
Where C b = l b + 9.5 l b C_b = \frac{l_b + 9.5}{l_b} C b = l b l b + 9.5 (for metric units, with bearing length l b ≥ 38 mm l_b \ge 38\text{ mm} l b ≥ 38 mm not closer than 75 mm 75\text{ mm} 75 mm to member ends).
5. Solid Sawn Lumber Column Design
Solid wood columns are designed as axially loaded rectangular compression members with dimensions b × d b \times d b × d (where d d d is the smaller cross-sectional dimension). The effective length is l e = K L l_e = K L l e = K L .
Slenderness Limitations
For solid sawn lumber columns, NSCP Chapter 6 (following the NDS) limits the slenderness ratio to:
- l e d ≤ 50 \frac{l_e}{d} \le 50 d l e ≤ 50
- Column Stability Factor ( C P C_P C P via Ylinen Formula)
The allowable compressive stress parallel to grain ( F c ′ F'_c F c ′ ) is determined by applying the column stability factor ( C P C_P C P ) :
F c ′ = F c ∗ ⋅ C P F'_c = F_c^* \cdot C_P F c ′ = F c ∗ ⋅ C P
Where F c ∗ = F c ⋅ C D ⋅ C M ⋅ C t F_c^* = F_c \cdot C_D \cdot C_M \cdot C_t F c ∗ = F c ⋅ C D ⋅ C M ⋅ C t is the reference compressive stress multiplied by all applicable factors except C P C_P C P .
The elastic Euler buckling stress for wood is:
F c E = 0.822 E min ′ ( l e / d ) 2 F_{cE} = \frac{0.822 E_{\min}'}{(l_e / d)^2} F c E = ( l e / d ) 2 0.822 E m i n ′
Where E min ′ = E min ⋅ C M ⋅ C t E_{\min}' = E_{\min} \cdot C_M \cdot C_t E m i n ′ = E m i n ⋅ C M ⋅ C t is the 5th percentile modulus of elasticity. The column stability factor C P C_P C P is derived from the Ylinen equation:
C P = 1 + ( F c E / F c ∗ ) 2 c − [ 1 + ( F c E / F c ∗ ) 2 c ] 2 − F c E / F c ∗ c C_P = \frac{1 + (F_{cE} / F_c^*)}{2 c} - \sqrt{\left[ \frac{1 + (F_{cE} / F_c^*)}{2 c} \right]^2 - \frac{F_{cE} / F_c^*}{c}} C P = 2 c 1 + ( F c E / F c ∗ ) − [ 2 c 1 + ( F c E / F c ∗ ) ] 2 − c F c E / F c ∗
c = 0.80 c = 0.80 c = 0.80 for solid sawn lumber columns.
c = 0.90 c = 0.90 c = 0.90 for glued laminated timber (glulam).
c = 0.85 c = 0.85 c = 0.85 for round timber poles and piles.
- 6. Comprehensive Worked Examples
- Worked Example 1: Sawn Timber Floor Joist Design
Problem: A residential floor framing system uses Apitong sawn timber joists with given allowable values F b = 16.5 MPa F_b = 16.5\text{ MPa} F b = 16.5 MPa , F v = 1.75 MPa F_v = 1.75\text{ MPa} F v = 1.75 MPa , E = 8 , 500 MPa E = 8,500\text{ MPa} E = 8 , 500 MPa on a simple span of L = 4.0 m L = 4.0\text{ m} L = 4.0 m . The joists are spaced 400 mm 400\text{ mm} 400 mm on center and covered with tongue-and-groove plywood sheathing. Total design service dead plus live load is w = 3.6 kN/m w = 3.6\text{ kN/m} w = 3.6 kN/m per joist. Joist cross-section is 50 mm × 200 mm 50\text{ mm} \times 200\text{ mm} 50 mm × 200 mm rough sawn. Service condition is dry ( C M = 1.0 C_M = 1.0 C M = 1.0 ), normal occupancy duration ( C D = 1.0 C_D = 1.0 C D = 1.0 ). Check: (a) bending stress, (b) horizontal shear stress at distance d d d from support, and (c) support bearing length for an allowable F c ⊥ = 3.5 MPa F_{c\perp} = 3.5\text{ MPa} F c ⊥ = 3.5 MPa .
Solution:
Step 1: Section Properties: b = 50 mm , d = 200 mm b = 50\text{ mm}, \quad d = 200\text{ mm} b = 50 mm , d = 200 mm S = b d 2 6 = 50 × ( 200 ) 2 6 = 333 , 333 mm 3 = 3.333 × 10 − 4 m 3 S = \frac{b d^2}{6} = \frac{50 \times (200)^2}{6} = 333,333\text{ mm}^3 = 3.333 \times 10^{-4}\text{ m}^3 S = 6 b d 2 = 6 50 × ( 200 ) 2 = 333 , 333 mm 3 = 3.333 × 1 0 − 4 m 3 A = b d = 50 × 200 = 10 , 000 mm 2 A = b d = 50 \times 200 = 10,000\text{ mm}^2 A = b d = 50 × 200 = 10 , 000 mm 2
Step 2: Flexural Stress Check: Maximum mid-span moment: M = w L 2 8 = 3.6 kN/m × ( 4.0 m ) 2 8 = 7.20 kN ⋅ m = 7.20 × 10 6 N ⋅ mm M = \frac{w L^2}{8} = \frac{3.6\text{ kN/m} \times (4.0\text{ m})^2}{8} = 7.20\text{ kN}\cdot\text{m} = 7.20 \times 10^6\text{ N}\cdot\text{mm} M = 8 w L 2 = 8 3.6 kN/m × ( 4.0 m ) 2 = 7.20 kN ⋅ m = 7.20 × 1 0 6 N ⋅ mm Actual bending stress: f b = M S = 7.20 × 10 6 333 , 333 = 21.60 MPa f_b = \frac{M}{S} = \frac{7.20 \times 10^6}{333,333} = 21.60\text{ MPa} f b = S M = 333 , 333 7.20 × 1 0 6 = 21.60 MPa Adjusted allowable bending stress (with repetitive member factor C r = 1.15 C_r = 1.15 C r = 1.15 since joists are spaced ≤ 600 mm \le 600\text{ mm} ≤ 600 mm ): F b ′ = F b ⋅ C D ⋅ C r = 16.5 MPa × 1.0 × 1.15 = 18.98 MPa F'_b = F_b \cdot C_D \cdot C_r = 16.5\text{ MPa} \times 1.0 \times 1.15 = 18.98\text{ MPa} F b ′ = F b ⋅ C D ⋅ C r = 16.5 MPa × 1.0 × 1.15 = 18.98 MPa Check: f b = 21.60 MPa > F b ′ = 18.98 MPa f_b = 21.60\text{ MPa} > F'_b = 18.98\text{ MPa} f b = 21.60 MPa > F b ′ = 18.98 MPa . The 50 mm × 200 mm 50\text{ mm} \times 200\text{ mm} 50 mm × 200 mm joist is overstressed by 13.8 % 13.8\% 13.8% in bending; a deeper joist (e.g., 50 mm × 250 mm 50\text{ mm} \times 250\text{ mm} 50 mm × 250 mm ) is required.
Step 3: Horizontal Shear Check (at distance d = 200 mm d = 200\text{ mm} d = 200 mm ): End reaction R = w L 2 = 3.6 × 4.0 2 = 7.20 kN R = \frac{w L}{2} = \frac{3.6 \times 4.0}{2} = 7.20\text{ kN} R = 2 w L = 2 3.6 × 4.0 = 7.20 kN . V design = R − w ⋅ d = 7.20 kN − ( 3.6 kN/m × 0.20 m ) = 7.20 − 0.72 = 6.48 kN V_{\text{design}} = R - w \cdot d = 7.20\text{ kN} - (3.6\text{ kN/m} \times 0.20\text{ m}) = 7.20 - 0.72 = 6.48\text{ kN} V design = R − w ⋅ d = 7.20 kN − ( 3.6 kN/m × 0.20 m ) = 7.20 − 0.72 = 6.48 kN Maximum horizontal shear stress: f v = 3 V design 2 b d = 3 × 6 , 480 N 2 × 10 , 000 mm 2 = 0.972 MPa f_v = \frac{3 V_{\text{design}}}{2 b d} = \frac{3 \times 6,480\text{ N}}{2 \times 10,000\text{ mm}^2} = 0.972\text{ MPa} f v = 2 b d 3 V design = 2 × 10 , 000 mm 2 3 × 6 , 480 N = 0.972 MPa Check: f v = 0.972 MPa ≤ F v ′ = 1.75 MPa f_v = 0.972\text{ MPa} \le F'_v = 1.75\text{ MPa} f v = 0.972 MPa ≤ F v ′ = 1.75 MPa . (Adequate in shear).
Step 4: Minimum Bearing Length: Reaction at support R = 7.20 kN = 7 , 200 N R = 7.20\text{ kN} = 7,200\text{ N} R = 7.20 kN = 7 , 200 N . A bearing,req = R F c ⊥ ′ = 7 , 200 N 3.5 MPa = 2 , 057.1 mm 2 A_{\text{bearing,req}} = \frac{R}{F'_{c\perp}} = \frac{7,200\text{ N}}{3.5\text{ MPa}} = 2,057.1\text{ mm}^2 A bearing,req = F c ⊥ ′ R = 3.5 MPa 7 , 200 N = 2 , 057.1 mm 2 l b = A bearing,req b = 2 , 057.1 mm 2 50 mm = 41.14 mm ≈ 42 mm l_b = \frac{A_{\text{bearing,req}}}{b} = \frac{2,057.1\text{ mm}^2}{50\text{ mm}} = 41.14\text{ mm} \approx 42\text{ mm} l b = b A bearing,req = 50 mm 2 , 057.1 mm 2 = 41.14 mm ≈ 42 mm
Worked Example 2: Timber Column Capacity
Problem: A Yakal solid wood column ( 150 mm × 150 mm 150\text{ mm} \times 150\text{ mm} 150 mm × 150 mm ) carries an axial compression load. The unbraced length is L = 3.0 m L = 3.0\text{ m} L = 3.0 m with pinned ends ( K = 1.0 K = 1.0 K = 1.0 ). Given reference values: F c = 15.8 MPa F_c = 15.8\text{ MPa} F c = 15.8 MPa , E min = 7 , 200 MPa E_{\min} = 7,200\text{ MPa} E m i n = 7 , 200 MPa . Normal duration ( C D = 1.0 C_D = 1.0 C D = 1.0 ), dry service ( C M = 1.0 C_M = 1.0 C M = 1.0 ). Compute the allowable axial load P allow P_{\text{allow}} P allow .
Solution:
Step 1: Slenderness Check: l e / d = 1.0 × 3 , 000 mm 150 mm = 20.0 ≤ 50 ( Satisfied ) l_e / d = \frac{1.0 \times 3,000\text{ mm}}{150\text{ mm}} = 20.0 \le 50 \quad (\text{Satisfied}) l e / d = 150 mm 1.0 × 3 , 000 mm = 20.0 ≤ 50 ( Satisfied )
Step 2: Euler Buckling Stress for Wood: F c E = 0.822 E min ( l e / d ) 2 = 0.822 × 7 , 200 ( 20.0 ) 2 = 5 , 918.4 400 = 14.80 MPa F_{cE} = \frac{0.822 E_{\min}}{(l_e / d)^2} = \frac{0.822 \times 7,200}{(20.0)^2} = \frac{5,918.4}{400} = 14.80\text{ MPa} F c E = ( l e / d ) 2 0.822 E m i n = ( 20.0 ) 2 0.822 × 7 , 200 = 400 5 , 918.4 = 14.80 MPa
Step 3: Column Stability Factor ( C P C_P C P with c = 0.80 c = 0.80 c = 0.80 ): F c ∗ = 15.8 MPa ⟹ F c E F c ∗ = 14.80 15.80 = 0.9367 F_c^* = 15.8\text{ MPa} \implies \frac{F_{cE}}{F_c^*} = \frac{14.80}{15.80} = 0.9367 F c ∗ = 15.8 MPa ⟹ F c ∗ F c E = 15.80 14.80 = 0.9367 1 + ( F c E / F c ∗ ) 2 c = 1 + 0.9367 2 ( 0.80 ) = 1.9367 1.60 = 1.2104 \frac{1 + (F_{cE} / F_c^*)}{2 c} = \frac{1 + 0.9367}{2(0.80)} = \frac{1.9367}{1.60} = 1.2104 2 c 1 + ( F c E / F c ∗ ) = 2 ( 0.80 ) 1 + 0.9367 = 1.60 1.9367 = 1.2104 C P = 1.2104 − ( 1.2104 ) 2 − 0.9367 0.80 = 1.2104 − 1.4651 − 1.1709 = 1.2104 − 0.2942 C_P = 1.2104 - \sqrt{(1.2104)^2 - \frac{0.9367}{0.80}} = 1.2104 - \sqrt{1.4651 - 1.1709} = 1.2104 - \sqrt{0.2942} C P = 1.2104 − ( 1.2104 ) 2 − 0.80 0.9367 = 1.2104 − 1.4651 − 1.1709 = 1.2104 − 0.2942 C P = 1.2104 − 0.5424 = 0.6680 C_P = 1.2104 - 0.5424 = 0.6680 C P = 1.2104 − 0.5424 = 0.6680
Step 4: Allowable Axial Compressive Load: F c ′ = F c ∗ ⋅ C P = 15.8 MPa × 0.6680 = 10.55 MPa F'_c = F_c^* \cdot C_P = 15.8\text{ MPa} \times 0.6680 = 10.55\text{ MPa} F c ′ = F c ∗ ⋅ C P = 15.8 MPa × 0.6680 = 10.55 MPa P allow = F c ′ ⋅ A = 10.55 MPa × ( 150 × 150 mm 2 ) = 10.55 × 22 , 500 = 237 , 375 N = 237.4 kN P_{\text{allow}} = F'_c \cdot A = 10.55\text{ MPa} \times (150 \times 150\text{ mm}^2) = 10.55 \times 22,500 = 237,375\text{ N} = 237.4\text{ kN} P allow = F c ′ ⋅ A = 10.55 MPa × ( 150 × 150 mm 2 ) = 10.55 × 22 , 500 = 237 , 375 N = 237.4 kN
7. Licensure Exam Pitfalls & Review Notes
Warning
Pitfall 1: Nominal vs. Dressed Dimensions In the Philippines, lumber may be sold rough sawn (full nominal size, e.g., 50 mm × 100 mm 50\text{ mm} \times 100\text{ mm} 50 mm × 100 mm ) or surfaced four sides (S4S, planed dimensions typically reduced by 6 to 10 mm 6\text{ to }10\text{ mm} 6 to 10 mm ). Read the problem statement carefully: using nominal dimensions for S4S lumber overestimates S S S by up to 25 % 25\% 25% and causes immediate failure in calculation.
Caution
Pitfall 2: The 1.5 Factor in Horizontal Shear The shear stress in a rectangular timber beam is f v = 3 V 2 b d = 1.5 V A f_v = \frac{3V}{2bd} = 1.5 \frac{V}{A} f v = 2 b d 3 V = 1.5 A V , NOT simply V A \frac{V}{A} A V . Forgetting the 1.5 1.5 1.5 multiplier is the single most common error on timber shear exam questions.
Tip
Pitfall 3: Load Duration Factor Exclusions Never apply the load duration factor C D C_D C D to modulus of elasticity ( E E E ) or to compression perpendicular to grain ( F c ⊥ F_{c\perp} F c ⊥ ). C D C_D C D modifies only time-dependent fracture strength properties ( F b , F t , F c , F v F_b, F_t, F_c, F_v F b , F t , F c , F v ).