Study guide

12.2 Single-Phase AC Circuits & Phasor Analysis

PRC Registered Electrical Engineer REE

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Overview, RA 7920 & Electrical Engineering Ethics

1.1 PRC Board of Electrical Engineering & REE Examination Overview 1.2 Republic Act No. 7920 (New Electrical Engineering Law) & License Classes 1.3 Code of Ethics & Professional Practice for Electrical Engineers

2 Chapter 2: Math — Algebra, Trig & Geometry

2.1 Algebraic Equations, Polynomials & Complex Numbers 2.2 Trigonometry — Identities, Triangles & Spherical Trig 2.3 Analytic & Solid Geometry

3 Chapter 3: Engineering Mathematics — Calculus & Differential Equations

3.1 Differential Calculus, Limits, Derivatives & Applications 3.2 Integral Calculus, Integration Techniques & Area/Volume Applications 3.3 Ordinary Differential Equations & Initial-Value Problems

4 Chapter 4: Engineering Mathematics — Advanced Math & Transform Methods

4.1 Laplace Transforms, Inverse Transforms & Circuit Applications 4.2 Fourier Series, Fourier Transforms & Frequency-Domain Analysis 4.3 Vector Analysis, Linear Algebra, Matrices & Complex Analysis

5 Chapter 5: Engineering Mathematics — Probability, Statistics & Engineering Data Analysis

5.1 Probability Theory, Counting Techniques & Bayes' Theorem 5.2 Engineering Data Analysis I — Descriptive Statistics & Probability Distributions 5.3 Engineering Data Analysis II — Confidence Intervals, Hypothesis Testing & Regression

6 Chapter 6: Engineering Mathematics — Numerical Methods & Analysis

6.1 Numerical Root-Finding & Solution of Linear Systems 6.2 Interpolation, Numerical Integration & Numerical Solution of ODEs

7 Chapter 7: ESAS — Physics, Chemistry & Computer Fundamentals

7.1 Physics for Engineers 7.2 General Chemistry & Materials Science 7.3 Computer Fundamentals, Programming & Data Logic 7.4 Logic Circuits, Switching Theory & Microprocessor Systems

8 Chapter 8: ESAS — Mechanics & Thermal-Fluid Engineering

8.1 Engineering Mechanics — Statics & Dynamics 8.2 Strength of Materials & Mechanics of Deformable Bodies 8.3 Thermal-Fluid Engineering — Thermodynamics & Fluid Mechanics

9 Chapter 9: ESAS — Engineering Economics, Management & Contracts

9.1 Engineering Economics & Depreciation 9.2 Engineering Management & Ethics 9.3 Philippine Electrical Engineering Law, Code & Contracts 9.4 Technopreneurship 101 & Management of Engineering Projects

10 Chapter 10: PEC 1 — Safety, Sizing & Protection

10.1 PEC Fundamentals, Safety Standards & Grounding/Bonding 10.2 Conductor Sizing, Ampacity Adjustment & Voltage Drop 10.3 Overcurrent Protection, Branch Circuit & Feeder Sizing 10.4 Basic Occupational Safety & Health (BOSH) and Electrical Safety Standards

11 Chapter 11: PEC 1 & 2 — Equipment & Utility Systems

11.1 PEC Equipment Installation & Wiring Methods 11.2 Utility Systems, Transformers & Switchgear 11.3 Special Occupancies & Hazardous Locations

12 Chapter 12: Electrical Professional — DC & AC Circuit Fundamentals

12.1 DC Circuit Analysis & Network Theorems 12.2 Single-Phase AC Circuits & Phasor Analysis 12.3 Balanced & Unbalanced Three-Phase AC Circuits

13 Chapter 13: Electrical Professional — EM Fields & Transients

13.1 Electrostatics, Magnetostatics & Maxwell's Equations 13.2 Electromagnetic Waves & Transmission Line Fields 13.3 First-Order & Second-Order Circuit Transients

14 Chapter 14: Electrical Professional — Electronics, Industrial Electronics & Communications

14.1 Electronics 1 & 2 — Semiconductor Devices & Analog Circuits 14.2 Electrical Apparatus & Devices — Industrial Electronics & Power Converters 14.3 Fundamentals of Electronic Communications

15 Chapter 15: Electrical Professional — Transformers & DC Machines

15.1 Single-Phase & Three-Phase Transformers 15.2 Transformer Connections & Special Transformers 15.3 DC Generators & DC Motors

16 Chapter 16: Electrical Professional — AC Synchronous & Induction Machinery

16.1 Synchronous Generators (Alternators) 16.2 Synchronous Motors & Special AC Machines 16.3 Three-Phase & Single-Phase Induction Motors

17 Chapter 17: Electrical Professional — Power Plants & Energy Conversion

17.1 Hydroelectric, Thermal & Combined Cycle Power Plants 17.2 Renewable Energy Systems & Geothermal Power Plants 17.3 Power Plant Economics, Load Curves & Energy Conversion

18 Chapter 18: Electrical Professional — Transmission & Distribution

18.1 Transmission Line Parameters & Performance Models 18.2 Mechanical Overhead Line Design, Underground Cables & Insulators 18.3 Distribution Systems, Substation Layouts & Power Flow Control

19 Chapter 19: Electrical Professional — Power System Analysis

19.1 The Per-Unit System, Base Conversion & Impedance Diagrams 19.2 Symmetrical Components & Unbalanced Fault Analysis 19.3 Load Flow, Economic Dispatch & Power System Stability

20 Chapter 20: Electrical Professional — Protection, Control, Instrumentation & Illumination

20.1 Power System Protection & Protective Relaying 20.2 Industrial Motor Control, Logic Circuits & PLC Automation 20.3 Electrical Instrumentation, Transducers & Measurement Systems 20.4 Illumination Engineering, Lighting Design & Photometrics 20.5 Feedback Control Systems & Research Methods

12.2 Single-Phase AC Circuits & Phasor Analysis

Key Takeaways Explain This Topic AI

For a pure sinusoidal voltage v ( t ) = V m sin ⁡ ( ω t + ϕ ) v(t) = V_m \sin(\omega t + \phi) v ( t ) = V m ​ sin ( ω t + ϕ ) , the Root-Mean-Square (RMS or effective) value is V rms = V m 2 ≈ 0.707 V m V_{\text{rms}} = \frac{V_m}{\sqrt{2}} \approx 0.707 V_m V rms ​ = 2 ​ V m ​ ​ ≈ 0.707 V m ​ , and the half-cycle average is V avg = 2 V m π ≈ 0.637 V m V_{\text{avg}} = \frac{2 V_m}{\pi} \approx 0.637 V_m V avg ​ = π 2 V m ​ ​ ≈ 0.637 V m ​ , yielding a Form Factor of 1.11 and Crest Factor of 1.414.

Complex impedance Z = R + j X = ∣ Z ∣ ∠ θ Z = R + jX = |Z|\angle \theta Z = R + j X = ∣ Z ∣∠ θ incorporates resistance R and reactance X = X L − X C X = X_L - X_C X = X L ​ − X C ​ , where inductive reactance X L = 2 π f L X_L = 2\pi f L X L ​ = 2 π f L and capacitive reactance X C = 1 2 π f C X_C = \frac{1}{2\pi f C} X C ​ = 2 π f C 1 ​ .

Series resonance in an RLC circuit occurs when X L = X C X_L = X_C X L ​ = X C ​ , producing a minimum impedance Z 0 = R Z_0 = R Z 0 ​ = R , unity power factor, maximum circuit current I 0 = V R I_0 = \frac{V}{R} I 0 ​ = R V ​ , resonant frequency f 0 = 1 2 π L C f_0 = \frac{1}{2\pi \sqrt{LC}} f 0 ​ = 2 π L C ​ 1 ​ , quality factor Q = ω 0 L R Q = \frac{\omega_0 L}{R} Q = R ω 0 ​ L ​ , and bandwidth BW = f 0 Q \text{BW} = \frac{f_0}{Q} BW = Q f 0 ​ ​ .

The AC power triangle relates Real Power P = V rms I rms cos ⁡ θ P = V_{\text{rms}} I_{\text{rms}} \cos\theta P = V rms ​ I rms ​ cos θ (Watts), Reactive Power Q = V rms I rms sin ⁡ θ Q = V_{\text{rms}} I_{\text{rms}} \sin\theta Q = V rms ​ I rms ​ sin θ (VARs), and Apparent Power S = V rms I rms S = V_{\text{rms}} I_{\text{rms}} S = V rms ​ I rms ​ (VA) through the complex power expression S = P + j Q = V I ∗ \mathbf{S} = P + jQ = \mathbf{V} \mathbf{I}^* S = P + j Q = V I ∗ .

Power factor correction reduces total line current and transmission I 2 R I^2 R I 2 R losses by connecting a shunt capacitor bank Q C = P ( tan ⁡ θ 1 − tan ⁡ θ 2 ) Q_C = P(\tan\theta_1 - \tan\theta_2) Q C ​ = P ( tan θ 1 ​ − tan θ 2 ​ ) in parallel with inductive loads without altering the useful real power P consumed by the load.

Last updated: August 2026

12.2 Single-Phase AC Circuits & Phasor Analysis

Alternating current (AC) circuit theory forms the core of power engineering. In steady-state sinusoidal analysis, time-domain differential equations transform into complex algebraic equations using phasors and complex impedance . This section examines AC waveforms, phasor domain algebra, RLC resonance, active and reactive power, and industrial power factor correction.

1. Sinusoidal Waveforms & Quantitative Parameters

A sinusoidal voltage wave is defined in the time domain as: v ( t ) = V m sin ⁡ ( ω t + ϕ ) v(t) = V_m \sin(\omega t + \phi) v ( t ) = V m ​ sin ( ω t + ϕ )

where V m V_m V m ​ is peak amplitude (V), ω = 2 π f \omega = 2 \pi f ω = 2 π f is angular frequency (rad/s), f = 1 T f = \frac{1}{T} f = T 1 ​ is cyclic frequency (Hz), T T T is period (s), and ϕ \phi ϕ is phase angle (rad or degrees).

Effective (RMS) & Average Values

Root-Mean-Square (RMS / Effective) Value: The equivalent DC value that delivers equal average thermal power to a resistor: V rms = 1 T ∫ 0 T v 2 ( t ) d t = V m 2 ≈ 0.7071 V m V_{\text{rms}} = \sqrt{\frac{1}{T} \int_{0}^{T} v^2(t) dt} = \frac{V_m}{\sqrt{2}} \approx 0.7071 V_m V rms ​ = T 1 ​ ∫ 0 T ​ v 2 ( t ) d t ​ = 2 ​ V m ​ ​ ≈ 0.7071 V m ​

Average Value (Half-Cycle Rectified): V avg = 2 T ∫ 0 T / 2 V m sin ⁡ ( ω t ) d t = 2 V m π ≈ 0.6366 V m V_{\text{avg}} = \frac{2}{T} \int_{0}^{T/2} V_m \sin(\omega t) dt = \frac{2 V_m}{\pi} \approx 0.6366 V_m V avg ​ = T 2 ​ ∫ 0 T /2 ​ V m ​ sin ( ω t ) d t = π 2 V m ​ ​ ≈ 0.6366 V m ​

Form Factor & Crest (Peak) Factor: Form Factor = V rms V avg = 0.7071 V m 0.6366 V m = π 2 2 ≈ 1.111 \text{Form Factor} = \frac{V_{\text{rms}}}{V_{\text{avg}}} = \frac{0.7071 V_m}{0.6366 V_m} = \frac{\pi}{2\sqrt{2}} \approx 1.111 Form Factor = V avg ​ V rms ​ ​ = 0.6366 V m ​ 0.7071 V m ​ ​ = 2 2 ​ π ​ ≈ 1.111 Crest (Peak) Factor = V m V rms = V m V m / 2 = 2 ≈ 1.414 \text{Crest (Peak) Factor} = \frac{V_m}{V_{\text{rms}}} = \frac{V_m}{V_m / \sqrt{2}} = \sqrt{2} \approx 1.414 Crest (Peak) Factor = V rms ​ V m ​ ​ = V m ​ / 2 ​ V m ​ ​ = 2 ​ ≈ 1.414

2. Phasors, Complex Impedance, and Admittance

Using Euler's identity ( e j θ = cos ⁡ θ + j sin ⁡ θ e^{j\theta} = \cos\theta + j\sin\theta e j θ = cos θ + j sin θ ), sinusoidal functions map into time-independent complex phasor vectors: V = V rms ∠ ϕ = V rms cos ⁡ ϕ + j V rms sin ⁡ ϕ \mathbf{V} = V_{\text{rms}} \angle \phi = V_{\text{rms}} \cos\phi + j V_{\text{rms}} \sin\phi V = V rms ​ ∠ ϕ = V rms ​ cos ϕ + j V rms ​ sin ϕ

Component Impedance in the Phasor Domain

Complex impedance Z \mathbf{Z} Z (Ohms, Ω \Omega Ω ) represents total opposition to sinusoidal current flow: Z = R + j X = ∣ Z ∣ ∠ θ z \mathbf{Z} = R + j X = |Z| \angle \theta_z Z = R + j X = ∣ Z ∣∠ θ z ​

Resistor ( R R R ): Z R = R ∠ 0 ∘ = R + j 0 \mathbf{Z}_R = R \angle 0^\circ = R + j0 Z R ​ = R ∠ 0 ∘ = R + j 0 (Voltage and current in phase).

Inductor ( L L L ): Z L = j ω L = ω L ∠ + 90 ∘ = 0 + j X L \mathbf{Z}_L = j \omega L = \omega L \angle +90^\circ = 0 + j X_L Z L ​ = jω L = ω L ∠ + 9 0 ∘ = 0 + j X L ​ (Voltage leads current by 90 ∘ 90^\circ 9 0 ∘ ).

Capacitor ( C C C ): Z C = 1 j ω C = − j 1 ω C = 1 ω C ∠ − 90 ∘ = 0 − j X C \mathbf{Z}_C = \frac{1}{j \omega C} = -j \frac{1}{\omega C} = \frac{1}{\omega C} \angle -90^\circ = 0 - j X_C Z C ​ = jω C 1 ​ = − j ω C 1 ​ = ω C 1 ​ ∠ − 9 0 ∘ = 0 − j X C ​ (Voltage lags current by 90 ∘ 90^\circ 9 0 ∘ ). Net Reactance: X = X L − X C = 2 π f L − 1 2 π f C \text{Net Reactance: } X = X_L - X_C = 2\pi f L - \frac{1}{2\pi f C} Net Reactance: X = X L ​ − X C ​ = 2 π f L − 2 π f C 1 ​ Impedance Magnitude: ∣ Z ∣ = R 2 + ( X L − X C ) 2 , θ z = arctan ⁡ ( X L − X C R ) \text{Impedance Magnitude: } |Z| = \sqrt{R^2 + (X_L - X_C)^2}, \quad \theta_z = \arctan\left(\frac{X_L - X_C}{R}\right) Impedance Magnitude: ∣ Z ∣ = R 2 + ( X L ​ − X C ​ ) 2 ​ , θ z ​ = arctan ( R X L ​ − X C ​ ​ )

Complex Admittance

Admittance Y \mathbf{Y} Y (Siemens, S \text{S} S ) is the reciprocal of impedance: Y = 1 Z = G + j B = ∣ Y ∣ ∠ − θ z \mathbf{Y} = \frac{1}{\mathbf{Z}} = G + j B = |Y| \angle -\theta_z Y = Z 1 ​ = G + j B = ∣ Y ∣∠ − θ z ​

where G = R R 2 + X 2 G = \frac{R}{R^2 + X^2} G = R 2 + X 2 R ​ is conductance ( S \text{S} S ) and B = − X R 2 + X 2 B = \frac{-X}{R^2 + X^2} B = R 2 + X 2 − X ​ is susceptance ( S \text{S} S ). For pure parallel branches, inductive susceptance is negative ( B L = − 1 ω L B_L = -\frac{1}{\omega L} B L ​ = − ω L 1 ​ ) and capacitive susceptance is positive ( B C = ω C B_C = \omega C B C ​ = ω C ).

3. Series and Parallel RLC Resonance

Resonance occurs when inductive and capacitive reactances cancel, causing the input impedance to become purely resistive.

Series RLC Resonance

In a series RLC circuit, Z = R + j ( X L − X C ) \mathbf{Z} = R + j(X_L - X_C) Z = R + j ( X L ​ − X C ​ ) . Resonance occurs when X L = X C X_L = X_C X L ​ = X C ​ : ω 0 L = 1 ω 0 C ⟹ ω 0 = 1 L C rad/s \omega_0 L = \frac{1}{\omega_0 C} \quad \implies \quad \omega_0 = \frac{1}{\sqrt{L C}} \quad \text{rad/s} ω 0 ​ L = ω 0 ​ C 1 ​ ⟹ ω 0 ​ = L C ​ 1 ​ rad/s f 0 = 1 2 π L C Hz f_0 = \frac{1}{2 \pi \sqrt{L C}} \quad \text{Hz} f 0 ​ = 2 π L C ​ 1 ​ Hz

Characteristics of Series Resonance:

Minimum circuit impedance: Z 0 = R + j 0 \mathbf{Z}_0 = R + j0 Z 0 ​ = R + j 0 .

Maximum line current: I 0 = V rms R I_0 = \frac{V_{\text{rms}}}{R} I 0 ​ = R V rms ​ ​ (in phase with voltage, PF = 1.0 \text{PF} = 1.0 PF = 1.0 ).

High inductor/capacitor reactive voltages: V L = V C = Q ⋅ V source V_L = V_C = Q \cdot V_{\text{source}} V L ​ = V C ​ = Q ⋅ V source ​ (Voltage magnification).

Quality Factor ( Q Q Q ) & Bandwidth (BW): Q = ω 0 L R = 1 ω 0 C R = 1 R L C Q = \frac{\omega_0 L}{R} = \frac{1}{\omega_0 C R} = \frac{1}{R} \sqrt{\frac{L}{C}} Q = R ω 0 ​ L ​ = ω 0 ​ CR 1 ​ = R 1 ​ C L ​ ​ Bandwidth (BW) = f 2 − f 1 = f 0 Q = R 2 π L Hz \text{Bandwidth (BW)} = f_2 - f_1 = \frac{f_0}{Q} = \frac{R}{2 \pi L} \quad \text{Hz} Bandwidth (BW) = f 2 ​ − f 1 ​ = Q f 0 ​ ​ = 2 π L R ​ Hz

where f 1 , f 2 f_1, f_2 f 1 ​ , f 2 ​ are upper and lower half-power ( − 3 dB -3\ \text{dB} − 3 dB ) cutoff frequencies: f 1 , f 2 = f 0 1 + ( 1 2 Q ) 2 ∓ f 0 2 Q f_1, f_2 = f_0 \sqrt{1 + \left(\frac{1}{2Q}\right)^2} \mp \frac{f_0}{2Q} f 1 ​ , f 2 ​ = f 0 ​ 1 + ( 2 Q 1 ​ ) 2 ​ ∓ 2 Q f 0 ​ ​

Parallel RLC Resonance (Anti-Resonance)

For an ideal parallel RLC circuit, admittance is Y = 1 R + j ( ω C − 1 ω L ) \mathbf{Y} = \frac{1}{R} + j\left(\omega C - \frac{1}{\omega L}\right) Y = R 1 ​ + j ( ω C − ω L 1 ​ ) . At resonance ( ω 0 = 1 L C \omega_0 = \frac{1}{\sqrt{LC}} ω 0 ​ = L C ​ 1 ​ ):

Maximum input impedance: Z p = R Z_p = R Z p ​ = R .

Minimum line current drawn from source: I min = V R I_{\text{min}} = \frac{V}{R} I min ​ = R V ​ .

High internal branch circulation current: I L = I C = Q ⋅ I line I_L = I_C = Q \cdot I_{\text{line}} I L ​ = I C ​ = Q ⋅ I line ​ (Current magnification).

4. AC Power Triangle & Power Factor Correction

When sinusoidal voltage V = V ∠ α \mathbf{V} = V \angle \alpha V = V ∠ α supplies current I = I ∠ β \mathbf{I} = I \angle \beta I = I ∠ β , the phase difference is θ = α − β \theta = \alpha - \beta θ = α − β .

Complex Power & Power Components

Complex Power S \mathbf{S} S (Volt-Amperes, VA \text{VA} VA ) is calculated using the conjugate of the current phasor: S = V I ∗ = V I ∠ ( α − β ) = P + j Q \mathbf{S} = \mathbf{V} \mathbf{I}^* = V I \angle (\alpha - \beta) = P + j Q S = V I ∗ = V I ∠ ( α − β ) = P + j Q

Power Component Formula Unit Physical Meaning

Real / Active Power ( P P P ) P = V I cos ⁡ θ = I 2 R P = V I \cos\theta = I^2 R P = V I cos θ = I 2 R Watts (W / kW) Useful work converted into heat, light, or mechanical output.

Reactive Power ( Q Q Q ) Q = V I sin ⁡ θ = I 2 X Q = V I \sin\theta = I^2 X Q = V I sin θ = I 2 X VAR / kVAR Energy oscillating between magnetic/electric fields and source.

Apparent Power ( S S S ) S = ∣ S ∣ = V I = P 2 + Q 2 S = \vert\mathbf{S}\vert= V I = \sqrt{P^2 + Q^2} S = ∣ S ∣ = V I = P 2 + Q 2 ​ VA / kVA Total rating required for transformers, generators, and lines.

Power Factor (PF) PF = cos ⁡ θ = P S \text{PF} = \cos\theta = \frac{P}{S} PF = cos θ = S P ​ Dimensionless Ratio of real work to total apparent volt-amperes.

Lagging vs. Leading PF: Power factor is lagging when current lags voltage (inductive load, Q > 0 Q > 0 Q > 0 ). Power factor is leading when current leads voltage (capacitive load, Q < 0 Q < 0 Q < 0 ).

Power Factor Correction (Capacitor Sizing)

Low lagging power factor increases distribution current I = P V cos ⁡ θ I = \frac{P}{V \cos\theta} I = V c o s θ P ​ , creating high line I 2 R I^2 R I 2 R losses and excessive voltage drop. Connecting shunt capacitors across inductive loads supplies reactive power locally. Q C = P ( tan ⁡ θ 1 − tan ⁡ θ 2 ) VAR Q_C = P \left( \tan\theta_1 - \tan\theta_2 \right) \quad \text{VAR} Q C ​ = P ( tan θ 1 ​ − tan θ 2 ​ ) VAR Required Shunt Capacitance: C = Q C ω V rms 2 = Q C 2 π f V rms 2 Farads \text{Required Shunt Capacitance: } C = \frac{Q_C}{\omega V_{\text{rms}}^2} = \frac{Q_C}{2 \pi f V_{\text{rms}}^2} \quad \text{Farads} Required Shunt Capacitance: C = ω V rms 2 ​ Q C ​ ​ = 2 π f V rms 2 ​ Q C ​ ​ Farads

  • Solved Board Exam Examples
  • Example 1: Series RLC Circuit & Power Triangle

Problem: A series circuit containing R = 12 Ω R = 12\ \Omega R = 12 Ω , L = 0.15 H L = 0.15\ \text{H} L = 0.15 H , and C = 100 μ F C = 100\ \mu\text{F} C = 100 μ F is connected to a 230 V 230\ \text{V} 230 V , 60 Hz 60\ \text{Hz} 60 Hz single-phase AC supply. Calculate: (a) total impedance Z \mathbf{Z} Z , (b) RMS current I I I , (c) active power P P P , (d) reactive power Q Q Q , and (e) power factor PF \text{PF} PF .

Solution:

Calculate inductive and capacitive reactances at f = 60 Hz f = 60\ \text{Hz} f = 60 Hz ( ω = 2 π ( 60 ) = 376.99 rad/s \omega = 2\pi(60) = 376.99\ \text{rad/s} ω = 2 π ( 60 ) = 376.99 rad/s ): X L = ω L = 376.99 × 0.15 = 56.55 Ω X_L = \omega L = 376.99 \times 0.15 = 56.55\ \Omega X L ​ = ω L = 376.99 × 0.15 = 56.55 Ω X C = 1 ω C = 1 376.99 × 100 × 10 − 6 = 1 0.0377 = 26.53 Ω X_C = \frac{1}{\omega C} = \frac{1}{376.99 \times 100 \times 10^{-6}} = \frac{1}{0.0377} = 26.53\ \Omega X C ​ = ω C 1 ​ = 376.99 × 100 × 1 0 − 6 1 ​ = 0.0377 1 ​ = 26.53 Ω

Calculate net reactance X X X and complex impedance Z \mathbf{Z} Z : X = X L − X C = 56.55 − 26.53 = 30.02 Ω X = X_L - X_C = 56.55 - 26.53 = 30.02\ \Omega X = X L ​ − X C ​ = 56.55 − 26.53 = 30.02 Ω Z = 12 + j 30.02 = 12 2 + 30.02 2 ∠ arctan ⁡ ( 30.02 12 ) = 32.33 Ω ∠ 68.2 ∘ \mathbf{Z} = 12 + j 30.02 = \sqrt{12^2 + 30.02^2} \angle \arctan\left(\frac{30.02}{12}\right) = 32.33\ \Omega \angle 68.2^\circ Z = 12 + j 30.02 = 1 2 2 + 30.0 2 2 ​ ∠ arctan ( 12 30.02 ​ ) = 32.33 Ω∠68. 2 ∘

Compute circuit RMS current I I I : I = V ∣ Z ∣ = 230 32.33 = 7.114 A I = \frac{V}{|Z|} = \frac{230}{32.33} = 7.114\ \text{A} I = ∣ Z ∣ V ​ = 32.33 230 ​ = 7.114 A

Compute Power Factor and Power Components: PF = cos ⁡ ( 68.2 ∘ ) = 0.3714 ( lagging ) \text{PF} = \cos(68.2^\circ) = 0.3714 \quad (\text{lagging}) PF = cos ( 68. 2 ∘ ) = 0.3714 ( lagging ) P = V I cos ⁡ θ = 230 × 7.114 × 0.3714 = 607.7 W P = V I \cos\theta = 230 \times 7.114 \times 0.3714 = 607.7\ \text{W} P = V I cos θ = 230 × 7.114 × 0.3714 = 607.7 W Q = V I sin ⁡ θ = 230 × 7.114 × sin ⁡ ( 68.2 ∘ ) = 1519.4 VAR (inductive) Q = V I \sin\theta = 230 \times 7.114 \times \sin(68.2^\circ) = 1519.4\ \text{VAR (inductive)} Q = V I sin θ = 230 × 7.114 × sin ( 68. 2 ∘ ) = 1519.4 VAR (inductive) S = V I = 230 × 7.114 = 1636.2 VA S = V I = 230 \times 7.114 = 1636.2\ \text{VA} S = V I = 230 × 7.114 = 1636.2 VA

Example 2: Industrial Power Factor Correction

Problem: An industrial plant consumes 100 kW 100\ \text{kW} 100 kW at a lagging power factor of 0.65 0.65 0.65 from a 460 V 460\ \text{V} 460 V , 60 Hz 60\ \text{Hz} 60 Hz supply. Determine: (a) the kVAR rating of a parallel capacitor bank needed to correct the overall power factor to 0.95 0.95 0.95 lagging, and (b) the required capacitance C C C in microfarads.

Solution:

Find initial phase angle θ 1 \theta_1 θ 1 ​ and initial reactive power Q 1 Q_1 Q 1 ​ : θ 1 = arccos ⁡ ( 0.65 ) = 49.46 ∘ ⟹ tan ⁡ θ 1 = 1.1691 \theta_1 = \arccos(0.65) = 49.46^\circ \implies \tan\theta_1 = 1.1691 θ 1 ​ = arccos ( 0.65 ) = 49.4 6 ∘ ⟹ tan θ 1 ​ = 1.1691 Q 1 = P tan ⁡ θ 1 = 100 kW × 1.1691 = 116.91 kVAR Q_1 = P \tan\theta_1 = 100\ \text{kW} \times 1.1691 = 116.91\ \text{kVAR} Q 1 ​ = P tan θ 1 ​ = 100 kW × 1.1691 = 116.91 kVAR

Find target phase angle θ 2 \theta_2 θ 2 ​ and target reactive power Q 2 Q_2 Q 2 ​ for PF = 0.95 \text{PF} = 0.95 PF = 0.95 : θ 2 = arccos ⁡ ( 0.95 ) = 18.19 ∘ ⟹ tan ⁡ θ 2 = 0.3287 \theta_2 = \arccos(0.95) = 18.19^\circ \implies \tan\theta_2 = 0.3287 θ 2 ​ = arccos ( 0.95 ) = 18.1 9 ∘ ⟹ tan θ 2 ​ = 0.3287 Q 2 = P tan ⁡ θ 2 = 100 kW × 0.3287 = 32.87 kVAR Q_2 = P \tan\theta_2 = 100\ \text{kW} \times 0.3287 = 32.87\ \text{kVAR} Q 2 ​ = P tan θ 2 ​ = 100 kW × 0.3287 = 32.87 kVAR

Calculate required capacitive kVAR rating Q C Q_C Q C ​ : Q C = Q 1 − Q 2 = 116.91 − 32.87 = 84.04 kVAR = 84 , 040 VAR Q_C = Q_1 - Q_2 = 116.91 - 32.87 = 84.04\ \text{kVAR} = 84,040\ \text{VAR} Q C ​ = Q 1 ​ − Q 2 ​ = 116.91 − 32.87 = 84.04 kVAR = 84 , 040 VAR

Calculate required shunt capacitance C C C : C = Q C 2 π f V 2 = 84 , 040 2 π × 60 × ( 460 ) 2 = 84 , 040 376.991 × 211 , 600 = 84 , 040 79 , 771 , 326 = 1.0535 × 10 − 3 F = 1053.5 μ F C = \frac{Q_C}{2 \pi f V^2} = \frac{84,040}{2 \pi \times 60 \times (460)^2} = \frac{84,040}{376.991 \times 211,600} = \frac{84,040}{79,771,326} = 1.0535 \times 10^{-3}\ \text{F} = 1053.5\ \mu\text{F} C = 2 π f V 2 Q C ​ ​ = 2 π × 60 × ( 460 ) 2 84 , 040 ​ = 376.991 × 211 , 600 84 , 040 ​ = 79 , 771 , 326 84 , 040 ​ = 1.0535 × 1 0 − 3 F = 1053.5 μ F

Loading diagram... AC Power Triangle Relationships and Power Factor Correction