Study guide
13.3 First-Order & Second-Order Circuit Transients
PRC Registered Electrical Engineer REE
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Overview, RA 7920 & Electrical Engineering Ethics
1.1 PRC Board of Electrical Engineering & REE Examination Overview 1.2 Republic Act No. 7920 (New Electrical Engineering Law) & License Classes 1.3 Code of Ethics & Professional Practice for Electrical Engineers
2 Chapter 2: Math — Algebra, Trig & Geometry
2.1 Algebraic Equations, Polynomials & Complex Numbers 2.2 Trigonometry — Identities, Triangles & Spherical Trig 2.3 Analytic & Solid Geometry
3 Chapter 3: Engineering Mathematics — Calculus & Differential Equations
3.1 Differential Calculus, Limits, Derivatives & Applications 3.2 Integral Calculus, Integration Techniques & Area/Volume Applications 3.3 Ordinary Differential Equations & Initial-Value Problems
4 Chapter 4: Engineering Mathematics — Advanced Math & Transform Methods
4.1 Laplace Transforms, Inverse Transforms & Circuit Applications 4.2 Fourier Series, Fourier Transforms & Frequency-Domain Analysis 4.3 Vector Analysis, Linear Algebra, Matrices & Complex Analysis
5 Chapter 5: Engineering Mathematics — Probability, Statistics & Engineering Data Analysis
5.1 Probability Theory, Counting Techniques & Bayes' Theorem 5.2 Engineering Data Analysis I — Descriptive Statistics & Probability Distributions 5.3 Engineering Data Analysis II — Confidence Intervals, Hypothesis Testing & Regression
6 Chapter 6: Engineering Mathematics — Numerical Methods & Analysis
6.1 Numerical Root-Finding & Solution of Linear Systems 6.2 Interpolation, Numerical Integration & Numerical Solution of ODEs
7 Chapter 7: ESAS — Physics, Chemistry & Computer Fundamentals
7.1 Physics for Engineers 7.2 General Chemistry & Materials Science 7.3 Computer Fundamentals, Programming & Data Logic 7.4 Logic Circuits, Switching Theory & Microprocessor Systems
8 Chapter 8: ESAS — Mechanics & Thermal-Fluid Engineering
8.1 Engineering Mechanics — Statics & Dynamics 8.2 Strength of Materials & Mechanics of Deformable Bodies 8.3 Thermal-Fluid Engineering — Thermodynamics & Fluid Mechanics
9 Chapter 9: ESAS — Engineering Economics, Management & Contracts
9.1 Engineering Economics & Depreciation 9.2 Engineering Management & Ethics 9.3 Philippine Electrical Engineering Law, Code & Contracts 9.4 Technopreneurship 101 & Management of Engineering Projects
10 Chapter 10: PEC 1 — Safety, Sizing & Protection
10.1 PEC Fundamentals, Safety Standards & Grounding/Bonding 10.2 Conductor Sizing, Ampacity Adjustment & Voltage Drop 10.3 Overcurrent Protection, Branch Circuit & Feeder Sizing 10.4 Basic Occupational Safety & Health (BOSH) and Electrical Safety Standards
11 Chapter 11: PEC 1 & 2 — Equipment & Utility Systems
11.1 PEC Equipment Installation & Wiring Methods 11.2 Utility Systems, Transformers & Switchgear 11.3 Special Occupancies & Hazardous Locations
12 Chapter 12: Electrical Professional — DC & AC Circuit Fundamentals
12.1 DC Circuit Analysis & Network Theorems 12.2 Single-Phase AC Circuits & Phasor Analysis 12.3 Balanced & Unbalanced Three-Phase AC Circuits
13 Chapter 13: Electrical Professional — EM Fields & Transients
13.1 Electrostatics, Magnetostatics & Maxwell's Equations 13.2 Electromagnetic Waves & Transmission Line Fields 13.3 First-Order & Second-Order Circuit Transients
14 Chapter 14: Electrical Professional — Electronics, Industrial Electronics & Communications
14.1 Electronics 1 & 2 — Semiconductor Devices & Analog Circuits 14.2 Electrical Apparatus & Devices — Industrial Electronics & Power Converters 14.3 Fundamentals of Electronic Communications
15 Chapter 15: Electrical Professional — Transformers & DC Machines
15.1 Single-Phase & Three-Phase Transformers 15.2 Transformer Connections & Special Transformers 15.3 DC Generators & DC Motors
16 Chapter 16: Electrical Professional — AC Synchronous & Induction Machinery
16.1 Synchronous Generators (Alternators) 16.2 Synchronous Motors & Special AC Machines 16.3 Three-Phase & Single-Phase Induction Motors
17 Chapter 17: Electrical Professional — Power Plants & Energy Conversion
17.1 Hydroelectric, Thermal & Combined Cycle Power Plants 17.2 Renewable Energy Systems & Geothermal Power Plants 17.3 Power Plant Economics, Load Curves & Energy Conversion
18 Chapter 18: Electrical Professional — Transmission & Distribution
18.1 Transmission Line Parameters & Performance Models 18.2 Mechanical Overhead Line Design, Underground Cables & Insulators 18.3 Distribution Systems, Substation Layouts & Power Flow Control
19 Chapter 19: Electrical Professional — Power System Analysis
19.1 The Per-Unit System, Base Conversion & Impedance Diagrams 19.2 Symmetrical Components & Unbalanced Fault Analysis 19.3 Load Flow, Economic Dispatch & Power System Stability
20 Chapter 20: Electrical Professional — Protection, Control, Instrumentation & Illumination
20.1 Power System Protection & Protective Relaying 20.2 Industrial Motor Control, Logic Circuits & PLC Automation 20.3 Electrical Instrumentation, Transducers & Measurement Systems 20.4 Illumination Engineering, Lighting Design & Photometrics 20.5 Feedback Control Systems & Research Methods
13.3 First-Order & Second-Order Circuit Transients
Key Takeaways Explain This Topic AI
First-order RC and RL transient responses follow exponential curves defined by time constants τ = R C \tau = RC τ = RC and τ = L R \tau = \frac{L}{R} τ = R L , reaching 63.2% of final value at 1 τ 1\tau 1 τ and over 99.3% at 5 τ 5\tau 5 τ .
Step response for first-order systems follows the general formula x ( t ) = x ( ∞ ) + [ x ( 0 + ) − x ( ∞ ) ] e − t / τ x(t) = x(\infty) + [x(0^+) - x(\infty)]e^{-t/\tau} x ( t ) = x ( ∞ ) + [ x ( 0 + ) − x ( ∞ )] e − t / τ , where initial state x ( 0 + ) x(0^+) x ( 0 + ) respects energy continuity: v C ( 0 + ) = v C ( 0 − ) v_C(0^+) = v_C(0^-) v C ( 0 + ) = v C ( 0 − ) and i L ( 0 + ) = i L ( 0 − ) i_L(0^+) = i_L(0^-) i L ( 0 + ) = i L ( 0 − ) .
Second-order RLC transient behavior is dictated by the characteristic equation s 2 + 2 α s + ω 0 2 = 0 s^2 + 2\alpha s + \omega_0^2 = 0 s 2 + 2 α s + ω 0 2 = 0 , with undamped natural frequency ω 0 = 1 L C \omega_0 = \frac{1}{\sqrt{LC}} ω 0 = L C 1 and attenuation factor α = R 2 L \alpha = \frac{R}{2L} α = 2 L R (series) or α = 1 2 R C \alpha = \frac{1}{2RC} α = 2 RC 1 (parallel).
RLC systems exhibit three distinct damping regimes based on root locations: Overdamped ( α > ω 0 \alpha > \omega_0 α > ω 0 , real distinct roots), Critically Damped ( α = ω 0 \alpha = \omega_0 α = ω 0 , real double root), and Underdamped ( α < ω 0 \alpha < \omega_0 α < ω 0 , complex conjugate roots with damped frequency ω d = ω 0 2 − α 2 \omega_d = \sqrt{\omega_0^2 - \alpha^2} ω d = ω 0 2 − α 2 ).
Power system switching transients generate high Transient Recovery Voltages (TRV), capacitive charging inrushes, and inductive voltage spikes ( v = L d i d t v = L \frac{di}{dt} v = L d t d i ), requiring protective snubber circuits and surge arresters.
Last updated: August 2026
13.3 First-Order & Second-Order Circuit Transients
Circuit transients represent the temporary transition state when an electrical network shifts from one steady-state condition to another due to switching operations, short-circuit faults, or sudden load changes. For the PRC Registered Electrical Engineer (REE) Licensure Examination , mastering time constants, step response formulas, second-order R L C RLC R L C damping classifications, and Laplace transform s s s -domain methods is vital.
1. Fundamentals of Transients & Initial Energy Continuity
Transients arise because energy stored in reactive elements cannot change instantaneously:
Inductor Magnetic Energy: W L = 1 2 L i L 2 ⟹ W_L = \frac{1}{2} L i_L^2 \implies W L = 2 1 L i L 2 ⟹ Inductor current cannot change instantaneously : i L ( 0 + ) = i L ( 0 − ) i_L(0^+) = i_L(0^-) i L ( 0 + ) = i L ( 0 − )
Capacitor Electric Energy: W C = 1 2 C v C 2 ⟹ W_C = \frac{1}{2} C v_C^2 \implies W C = 2 1 C v C 2 ⟹ Capacitor voltage cannot change instantaneously : v C ( 0 + ) = v C ( 0 − ) v_C(0^+) = v_C(0^-) v C ( 0 + ) = v C ( 0 − )
where t = 0 − t = 0^- t = 0 − represents the instant immediately prior to switching, and t = 0 + t = 0^+ t = 0 + represents the instant immediately after switching.
2. First-Order R C RC RC and R L RL R L Transients
First-order circuits contain a single energy storage element (or equivalent L L L or C C C ) alongside resistive networks.
Time Constant ( τ \tau τ ) Equations
R C RC RC Circuit Time Constant: τ = R eq C ( seconds ) \tau = R_{\text{eq}} C \quad (\text{seconds}) τ = R eq C ( seconds )
R L RL R L Circuit Time Constant: τ = L R eq ( seconds ) \tau = \frac{L}{R_{\text{eq}}} \quad (\text{seconds}) τ = R eq L ( seconds )
where R eq R_{\text{eq}} R eq is the Thevenin equivalent resistance seen from the terminals of the storage element.
General First-Order Step Response Formula
For any first-order variable x ( t ) x(t) x ( t ) (representing capacitor voltage v C ( t ) v_C(t) v C ( t ) or inductor current i L ( t ) i_L(t) i L ( t ) ): x ( t ) = x ( ∞ ) + [ x ( 0 + ) − x ( ∞ ) ] e − t / τ for t ≥ 0 x(t) = x(\infty) + \left[ x(0^+) - x(\infty) \right] e^{-t/\tau} \quad \text{for } t \ge 0 x ( t ) = x ( ∞ ) + [ x ( 0 + ) − x ( ∞ ) ] e − t / τ for t ≥ 0
where:
- x ( 0 + ) x(0^+) x ( 0 + ) is the initial value immediately after switching;
- x ( ∞ ) x(\infty) x ( ∞ ) is the final steady-state value as t → ∞ t \to \infty t → ∞ ;
τ \tau τ is the circuit time constant.
Time Constant Progression & Response Characteristics
Elapsed Time ( t t t ) Remaining Transient Amplitude ( e − t / τ e^{-t/\tau} e − t / τ ) Percentage of Total Change Completed
- 1 τ 1\tau 1 τ e − 1 ≈ 0.3679 e^{-1} \approx 0.3679 e − 1 ≈ 0.3679 63.2 % 63.2\% 63.2%
- 2 τ 2\tau 2 τ e − 2 ≈ 0.1353 e^{-2} \approx 0.1353 e − 2 ≈ 0.1353 86.5 % 86.5\% 86.5%
- 3 τ 3\tau 3 τ e − 3 ≈ 0.0498 e^{-3} \approx 0.0498 e − 3 ≈ 0.0498 95.0 % 95.0\% 95.0%
- 4 τ 4\tau 4 τ e − 4 ≈ 0.0183 e^{-4} \approx 0.0183 e − 4 ≈ 0.0183 98.2 % 98.2\% 98.2%
5 τ 5\tau 5 τ e − 5 ≈ 0.0067 e^{-5} \approx 0.0067 e − 5 ≈ 0.0067 99.3 % 99.3\% 99.3% (Considered Steady State)
3. Second-Order R L C RLC R L C Transients & Damping Regimes
Second-order circuits contain two uncoupled energy storage elements ( L L L and C C C ), yielding a second-order linear differential equation.
Governing Differential Equations
Series R L C RLC R L C Circuit: L d 2 i ( t ) d t 2 + R d i ( t ) d t + 1 C i ( t ) = 0 ⟹ d 2 i d t 2 + 2 α d i d t + ω 0 2 i = 0 L \frac{d^2 i(t)}{dt^2} + R \frac{di(t)}{dt} + \frac{1}{C} i(t) = 0 \implies \frac{d^2 i}{dt^2} + 2\alpha \frac{di}{dt} + \omega_0^2 i = 0 L d t 2 d 2 i ( t ) + R d t d i ( t ) + C 1 i ( t ) = 0 ⟹ d t 2 d 2 i + 2 α d t d i + ω 0 2 i = 0
Parallel R L C RLC R L C Circuit: C d 2 v ( t ) d t 2 + 1 R d v ( t ) d t + 1 L v ( t ) = 0 ⟹ d 2 v d t 2 + 2 α d v d t + ω 0 2 v = 0 C \frac{d^2 v(t)}{dt^2} + \frac{1}{R} \frac{dv(t)}{dt} + \frac{1}{L} v(t) = 0 \implies \frac{d^2 v}{dt^2} + 2\alpha \frac{dv}{dt} + \omega_0^2 v = 0 C d t 2 d 2 v ( t ) + R 1 d t d v ( t ) + L 1 v ( t ) = 0 ⟹ d t 2 d 2 v + 2 α d t d v + ω 0 2 v = 0
Key Parameters
Undamped Natural Frequency ( ω 0 \omega_0 ω 0 ): ω 0 = 1 L C ( rad/s ) \omega_0 = \frac{1}{\sqrt{LC}} \quad (\text{rad/s}) ω 0 = L C 1 ( rad/s )
Damping Attenuation Factor ( α \alpha α ): Series R L C : α = R 2 L , Parallel R L C : α = 1 2 R C \text{Series } RLC: \alpha = \frac{R}{2L}, \qquad \text{Parallel } RLC: \alpha = \frac{1}{2RC} Series R L C : α = 2 L R , Parallel R L C : α = 2 RC 1
- Damping Ratio ( ζ \zeta ζ ): ζ = α ω 0 \zeta = \frac{\alpha}{\omega_0} ζ = ω 0 α
- Characteristic Equation & Roots
Substituting x ( t ) = A e s t x(t) = A e^{st} x ( t ) = A e s t yields the characteristic equation: s 2 + 2 α s + ω 0 2 = 0 s^2 + 2\alpha s + \omega_0^2 = 0 s 2 + 2 α s + ω 0 2 = 0
Roots are given by the quadratic formula: s 1 , 2 = − α ± α 2 − ω 0 2 s_{1,2} = -\alpha \pm \sqrt{\alpha^2 - \omega_0^2} s 1 , 2 = − α ± α 2 − ω 0 2
Classification of Damping Regimes
Damping State Mathematical Condition Characteristic Roots ( s 1 , 2 s_{1,2} s 1 , 2 ) Time-Domain Response Expression x ( t ) x(t) x ( t ) Physical System Trajectory
Overdamped α > ω 0 \alpha > \omega_0 α > ω 0 ( ζ > 1 \zeta > 1 ζ > 1 ) Two real, distinct negative roots x ( t ) = A 1 e s 1 t + A 2 e s 2 t x(t) = A_1 e^{s_1 t} + A_2 e^{s_2 t} x ( t ) = A 1 e s 1 t + A 2 e s 2 t Slow, non-oscillatory exponential return to steady state.
Critically Damped α = ω 0 \alpha = \omega_0 α = ω 0 ( ζ = 1 \zeta = 1 ζ = 1 ) Two real, equal roots ( s 1 = s 2 = − α s_1 = s_2 = -\alpha s 1 = s 2 = − α ) x ( t ) = ( A 1 + A 2 t ) e − α t x(t) = (A_1 + A_2 t) e^{-\alpha t} x ( t ) = ( A 1 + A 2 t ) e − α t Fastest non-oscillatory return to equilibrium without overshoot.
Underdamped α < ω 0 \alpha < \omega_0 α < ω 0 ( ζ < 1 \zeta < 1 ζ < 1 ) Complex conjugate roots ( − α ± j ω d -\alpha \pm j\omega_d − α ± j ω d ) x ( t ) = e − α t [ A 1 cos ( ω d t ) + A 2 sin ( ω d t ) ] x(t) = e^{-\alpha t} \left[ A_1 \cos(\omega_d t) + A_2 \sin(\omega_d t) \right] x ( t ) = e − α t [ A 1 cos ( ω d t ) + A 2 sin ( ω d t ) ] Damped oscillatory response with frequency ω d = ω 0 2 − α 2 \omega_d = \sqrt{\omega_0^2 - \alpha^2} ω d = ω 0 2 − α 2 . Damped Natural Frequency: ω d = ω 0 2 − α 2 ( rad/s ) , f d = ω d 2 π ( Hz ) \text{Damped Natural Frequency: } \omega_d = \sqrt{\omega_0^2 - \alpha^2} \quad (\text{rad/s}), \qquad f_d = \frac{\omega_d}{2\pi} \quad (\text{Hz}) Damped Natural Frequency: ω d = ω 0 2 − α 2 ( rad/s ) , f d = 2 π ω d ( Hz )
4. Laplace Transform ( s s s -Domain) Methods for Transients
Laplace transform converts differential equations into algebraic equations in the complex frequency domain ( s = σ + j ω s = \sigma + j\omega s = σ + jω ).
- Key Laplace Transform Pairs
- L { 1 } = 1 s \mathcal{L}\{ 1 \} = \frac{1}{s} L { 1 } = s 1
- L { e − a t } = 1 s + a \mathcal{L}\{ e^{-at} \} = \frac{1}{s + a} L { e − a t } = s + a 1
L { sin ( ω t ) } = ω s 2 + ω 2 \mathcal{L}\{ \sin(\omega t) \} = \frac{\omega}{s^2 + \omega^2} L { sin ( ω t )} = s 2 + ω 2 ω
L { cos ( ω t ) } = s s 2 + ω 2 \mathcal{L}\{ \cos(\omega t) \} = \frac{s}{s^2 + \omega^2} L { cos ( ω t )} = s 2 + ω 2 s
L { d f ( t ) d t } = s F ( s ) − f ( 0 + ) \mathcal{L}\left\{ \frac{df(t)}{dt} \right\} = s F(s) - f(0^+) L { d t df ( t ) } = s F ( s ) − f ( 0 + )
L { d 2 f ( t ) d t 2 } = s 2 F ( s ) − s f ( 0 + ) − f ′ ( 0 + ) \mathcal{L}\left\{ \frac{d^2f(t)}{dt^2} \right\} = s^2 F(s) - s f(0^+) - f'(0^+) L { d t 2 d 2 f ( t ) } = s 2 F ( s ) − s f ( 0 + ) − f ′ ( 0 + )
- Circuit Element Equivalent s s s -Domain Models
- Resistor ( R R R ): Z ( s ) = R Z(s) = R Z ( s ) = R
Inductor ( L L L ): Series combination of impedance s L sL s L and voltage source L i L ( 0 + ) L i_L(0^+) L i L ( 0 + ) (or parallel current source i L ( 0 + ) s \frac{i_L(0^+)}{s} s i L ( 0 + ) )
Capacitor ( C C C ): Series combination of impedance 1 s C \frac{1}{sC} s C 1 and voltage source v C ( 0 + ) s \frac{v_C(0^+)}{s} s v C ( 0 + )
5. Power System Switching Transients & Protective Measures
In high-voltage power networks, transient phenomena can trigger destructive voltage spikes and insulation breakdown:
Transient Recovery Voltage (TRV): When a circuit breaker interrupts an inductive fault current, high frequency oscillations occur across the opening contacts as energy transfers between grid inductance and stray capacitance.
Inductive Kickback ( v L = L d i d t v_L = L \frac{di}{dt} v L = L d t d i ): Opening an inductive circuit (such as a motor field winding or transformer) abruptly produces severe overvoltage surges. Protection requires RC snubber circuits, flyback diodes, or metal-oxide varistors (MOVs).
Capacitor Bank Inrush Current: Energizing distribution capacitor banks creates high-magnitude, high-frequency current transients. Damping reactors or pre-insertion resistors are installed to limit inrush currents.
- Solved Board Exam Numerical Problems
- Problem 1: First-Order R L RL R L Transient Step Response
Question: A series R L RL R L circuit containing a resistor R = 10 Ω R = 10\ \Omega R = 10 Ω and an inductor L = 2.0 H L = 2.0\ \text{H} L = 2.0 H is connected to a constant 100 V 100\ \text{V} 100 V DC source at t = 0 t = 0 t = 0 . Assuming zero initial current ( i L ( 0 − ) = 0 i_L(0^-) = 0 i L ( 0 − ) = 0 ), determine: (a) the circuit time constant τ \tau τ , (b) the current at t = 0.10 s t = 0.10\ \text{s} t = 0.10 s , (c) the steady-state current as t → ∞ t \to \infty t → ∞ , and (d) the time required for current to reach 90 % 90\% 90% of its final value.
Solution:
Calculate time constant τ \tau τ : τ = L R = 2.0 H 10 Ω = 0.20 seconds \tau = \frac{L}{R} = \frac{2.0\ \text{H}}{10\ \Omega} = 0.20\ \text{seconds} τ = R L = 10 Ω 2.0 H = 0.20 seconds
Determine steady-state current i ( ∞ ) i(\infty) i ( ∞ ) : i ( ∞ ) = V R = 100 V 10 Ω = 10 Amperes i(\infty) = \frac{V}{R} = \frac{100\ \text{V}}{10\ \Omega} = 10\ \text{Amperes} i ( ∞ ) = R V = 10 Ω 100 V = 10 Amperes
Apply first-order step response equation: i ( t ) = i ( ∞ ) + [ i ( 0 + ) − i ( ∞ ) ] e − t / τ = 10 + [ 0 − 10 ] e − t / 0.20 = 10 ( 1 − e − 5 t ) A i(t) = i(\infty) + [i(0^+) - i(\infty)] e^{-t/\tau} = 10 + [0 - 10] e^{-t/0.20} = 10 \left( 1 - e^{-5t} \right)\ \text{A} i ( t ) = i ( ∞ ) + [ i ( 0 + ) − i ( ∞ )] e − t / τ = 10 + [ 0 − 10 ] e − t /0.20 = 10 ( 1 − e − 5 t ) A
Compute current at t = 0.10 s t = 0.10\ \text{s} t = 0.10 s : i ( 0.10 ) = 10 ( 1 − e − 5 ( 0.10 ) ) = 10 ( 1 − e − 0.5 ) = 10 ( 1 − 0.6065 ) = 3.935 Amperes i(0.10) = 10 \left( 1 - e^{-5(0.10)} \right) = 10 \left( 1 - e^{-0.5} \right) = 10 (1 - 0.6065) = 3.935\ \text{Amperes} i ( 0.10 ) = 10 ( 1 − e − 5 ( 0.10 ) ) = 10 ( 1 − e − 0.5 ) = 10 ( 1 − 0.6065 ) = 3.935 Amperes
Calculate time t t t to reach 90 % 90\% 90% ( 9.0 A 9.0\ \text{A} 9.0 A ): 9.0 = 10 ( 1 − e − t / 0.20 ) ⟹ 0.90 = 1 − e − t / 0.20 ⟹ e − t / 0.20 = 0.10 9.0 = 10 \left( 1 - e^{-t/0.20} \right) \implies 0.90 = 1 - e^{-t/0.20} \implies e^{-t/0.20} = 0.10 9.0 = 10 ( 1 − e − t /0.20 ) ⟹ 0.90 = 1 − e − t /0.20 ⟹ e − t /0.20 = 0.10 − t 0.20 = ln ( 0.10 ) = − 2.3026 ⟹ t = 0.20 × 2.3026 = 0.4605 seconds -\frac{t}{0.20} = \ln(0.10) = -2.3026 \implies t = 0.20 \times 2.3026 = 0.4605\ \text{seconds} − 0.20 t = ln ( 0.10 ) = − 2.3026 ⟹ t = 0.20 × 2.3026 = 0.4605 seconds
Problem 2: Series R L C RLC R L C Transient Response Classification & Frequency
Question: A series R L C RLC R L C circuit has parameters R = 40 Ω R = 40\ \Omega R = 40 Ω , L = 100 mH L = 100\ \text{mH} L = 100 mH ( 0.10 H 0.10\ \text{H} 0.10 H ), and C = 25 μ F C = 25\ \mu\text{F} C = 25 μ F ( 25 × 10 − 6 F 25 \times 10^{-6}\ \text{F} 25 × 1 0 − 6 F ). Determine: (a) the attenuation factor α \alpha α , (b) the undamped natural frequency ω 0 \omega_0 ω 0 , (c) the damping regime classification, and (d) the damped natural frequency ω d \omega_d ω d and cyclic frequency f d f_d f d .
Solution:
Calculate attenuation factor α \alpha α for series R L C RLC R L C : α = R 2 L = 40 2 × 0.10 = 40 0.20 = 200 rad/s \alpha = \frac{R}{2L} = \frac{40}{2 \times 0.10} = \frac{40}{0.20} = 200\ \text{rad/s} α = 2 L R = 2 × 0.10 40 = 0.20 40 = 200 rad/s
Calculate undamped natural frequency ω 0 \omega_0 ω 0 : ω 0 = 1 L C = 1 0.10 × 25 × 10 − 6 = 1 2.5 × 10 − 6 = 1 0.0015811 = 632.46 rad/s \omega_0 = \frac{1}{\sqrt{LC}} = \frac{1}{\sqrt{0.10 \times 25 \times 10^{-6}}} = \frac{1}{\sqrt{2.5 \times 10^{-6}}} = \frac{1}{0.0015811} = 632.46\ \text{rad/s} ω 0 = L C 1 = 0.10 × 25 × 1 0 − 6 1 = 2.5 × 1 0 − 6 1 = 0.0015811 1 = 632.46 rad/s
Classify damping regime by comparing α \alpha α and ω 0 \omega_0 ω 0 : Since α = 200 rad/s < ω 0 = 632.46 rad/s , the system is U N D E R D A M P E D (oscillatory). \text{Since } \alpha = 200\ \text{rad/s} < \omega_0 = 632.46\ \text{rad/s}, \text{ the system is } \mathbf{UNDERDAMPED} \text{ (oscillatory).} Since α = 200 rad/s < ω 0 = 632.46 rad/s , the system is UNDERDAMPED (oscillatory).
Calculate damped natural frequency ω d \omega_d ω d and cyclic frequency f d f_d f d : ω d = ω 0 2 − α 2 = ( 632.46 ) 2 − ( 200 ) 2 = 400 , 000 − 40 , 000 = 360 , 000 = 600 rad/s \omega_d = \sqrt{\omega_0^2 - \alpha^2} = \sqrt{(632.46)^2 - (200)^2} = \sqrt{400,000 - 40,000} = \sqrt{360,000} = 600\ \text{rad/s} ω d = ω 0 2 − α 2 = ( 632.46 ) 2 − ( 200 ) 2 = 400 , 000 − 40 , 000 = 360 , 000 = 600 rad/s f d = ω d 2 π = 600 2 π = 95.49 Hz f_d = \frac{\omega_d}{2\pi} = \frac{600}{2\pi} = 95.49\ \text{Hz} f d = 2 π ω d = 2 π 600 = 95.49 Hz