Study guide
17.1 Hydroelectric, Thermal & Combined Cycle Power Plants
PRC Registered Electrical Engineer REE
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Overview, RA 7920 & Electrical Engineering Ethics
1.1 PRC Board of Electrical Engineering & REE Examination Overview 1.2 Republic Act No. 7920 (New Electrical Engineering Law) & License Classes 1.3 Code of Ethics & Professional Practice for Electrical Engineers
2 Chapter 2: Math — Algebra, Trig & Geometry
2.1 Algebraic Equations, Polynomials & Complex Numbers 2.2 Trigonometry — Identities, Triangles & Spherical Trig 2.3 Analytic & Solid Geometry
3 Chapter 3: Engineering Mathematics — Calculus & Differential Equations
3.1 Differential Calculus, Limits, Derivatives & Applications 3.2 Integral Calculus, Integration Techniques & Area/Volume Applications 3.3 Ordinary Differential Equations & Initial-Value Problems
4 Chapter 4: Engineering Mathematics — Advanced Math & Transform Methods
4.1 Laplace Transforms, Inverse Transforms & Circuit Applications 4.2 Fourier Series, Fourier Transforms & Frequency-Domain Analysis 4.3 Vector Analysis, Linear Algebra, Matrices & Complex Analysis
5 Chapter 5: Engineering Mathematics — Probability, Statistics & Engineering Data Analysis
5.1 Probability Theory, Counting Techniques & Bayes' Theorem 5.2 Engineering Data Analysis I — Descriptive Statistics & Probability Distributions 5.3 Engineering Data Analysis II — Confidence Intervals, Hypothesis Testing & Regression
6 Chapter 6: Engineering Mathematics — Numerical Methods & Analysis
6.1 Numerical Root-Finding & Solution of Linear Systems 6.2 Interpolation, Numerical Integration & Numerical Solution of ODEs
7 Chapter 7: ESAS — Physics, Chemistry & Computer Fundamentals
7.1 Physics for Engineers 7.2 General Chemistry & Materials Science 7.3 Computer Fundamentals, Programming & Data Logic 7.4 Logic Circuits, Switching Theory & Microprocessor Systems
8 Chapter 8: ESAS — Mechanics & Thermal-Fluid Engineering
8.1 Engineering Mechanics — Statics & Dynamics 8.2 Strength of Materials & Mechanics of Deformable Bodies 8.3 Thermal-Fluid Engineering — Thermodynamics & Fluid Mechanics
9 Chapter 9: ESAS — Engineering Economics, Management & Contracts
9.1 Engineering Economics & Depreciation 9.2 Engineering Management & Ethics 9.3 Philippine Electrical Engineering Law, Code & Contracts 9.4 Technopreneurship 101 & Management of Engineering Projects
10 Chapter 10: PEC 1 — Safety, Sizing & Protection
10.1 PEC Fundamentals, Safety Standards & Grounding/Bonding 10.2 Conductor Sizing, Ampacity Adjustment & Voltage Drop 10.3 Overcurrent Protection, Branch Circuit & Feeder Sizing 10.4 Basic Occupational Safety & Health (BOSH) and Electrical Safety Standards
11 Chapter 11: PEC 1 & 2 — Equipment & Utility Systems
11.1 PEC Equipment Installation & Wiring Methods 11.2 Utility Systems, Transformers & Switchgear 11.3 Special Occupancies & Hazardous Locations
12 Chapter 12: Electrical Professional — DC & AC Circuit Fundamentals
12.1 DC Circuit Analysis & Network Theorems 12.2 Single-Phase AC Circuits & Phasor Analysis 12.3 Balanced & Unbalanced Three-Phase AC Circuits
13 Chapter 13: Electrical Professional — EM Fields & Transients
13.1 Electrostatics, Magnetostatics & Maxwell's Equations 13.2 Electromagnetic Waves & Transmission Line Fields 13.3 First-Order & Second-Order Circuit Transients
14 Chapter 14: Electrical Professional — Electronics, Industrial Electronics & Communications
14.1 Electronics 1 & 2 — Semiconductor Devices & Analog Circuits 14.2 Electrical Apparatus & Devices — Industrial Electronics & Power Converters 14.3 Fundamentals of Electronic Communications
15 Chapter 15: Electrical Professional — Transformers & DC Machines
15.1 Single-Phase & Three-Phase Transformers 15.2 Transformer Connections & Special Transformers 15.3 DC Generators & DC Motors
16 Chapter 16: Electrical Professional — AC Synchronous & Induction Machinery
16.1 Synchronous Generators (Alternators) 16.2 Synchronous Motors & Special AC Machines 16.3 Three-Phase & Single-Phase Induction Motors
17 Chapter 17: Electrical Professional — Power Plants & Energy Conversion
17.1 Hydroelectric, Thermal & Combined Cycle Power Plants 17.2 Renewable Energy Systems & Geothermal Power Plants 17.3 Power Plant Economics, Load Curves & Energy Conversion
18 Chapter 18: Electrical Professional — Transmission & Distribution
18.1 Transmission Line Parameters & Performance Models 18.2 Mechanical Overhead Line Design, Underground Cables & Insulators 18.3 Distribution Systems, Substation Layouts & Power Flow Control
19 Chapter 19: Electrical Professional — Power System Analysis
19.1 The Per-Unit System, Base Conversion & Impedance Diagrams 19.2 Symmetrical Components & Unbalanced Fault Analysis 19.3 Load Flow, Economic Dispatch & Power System Stability
20 Chapter 20: Electrical Professional — Protection, Control, Instrumentation & Illumination
20.1 Power System Protection & Protective Relaying 20.2 Industrial Motor Control, Logic Circuits & PLC Automation 20.3 Electrical Instrumentation, Transducers & Measurement Systems 20.4 Illumination Engineering, Lighting Design & Photometrics 20.5 Feedback Control Systems & Research Methods
17.1 Hydroelectric, Thermal & Combined Cycle Power Plants
Key Takeaways Explain This Topic AI
Hydroelectric power generation obeys P = ρ g Q H η overall = 9.81 Q H η overall P = \rho g Q H \eta_{\text{overall}} = 9.81 Q H \eta_{\text{overall}} P = ρ g Q H η overall = 9.81 Q H η overall kW, where turbine selection depends on net head: Pelton (impulse, > 300 m >300\text{ m} > 300 m ), Francis (reaction, 30 – 300 m 30\text{--}300\text{ m} 30 – 300 m ), and Kaplan (axial reaction, < 30 m <30\text{ m} < 30 m ).
Surge tanks located on penstocks absorb hydraulic water hammer pressure transients during sudden governor load rejection and supply supplementary water volume during rapid load acceptance.
Thermal Rankine cycle power plant overall thermal efficiency ( η overall = η boiler × η thermal × η generator × η auxiliary ≈ 32 % – 40 % \eta_{\text{overall}} = \eta_{\text{boiler}} \times \eta_{\text{thermal}} \times \eta_{\text{generator}} \times \eta_{\text{auxiliary}} \approx 32\%\text{--}40\% η overall = η boiler × η thermal × η generator × η auxiliary ≈ 32% – 40% ) is maximized by using superheaters, reheaters, economizers, and air preheaters.
Combined Cycle Gas Turbine (CCGT) systems couple a high-temperature open Brayton cycle gas turbine with a Heat Recovery Steam Generator (HRSG) Rankine cycle, elevating thermal efficiency up to 55 % – 63 % 55\%\text{--}63\% 55% – 63% .
Draft tubes in reaction turbines recover kinetic energy of water leaving the runner by converting velocity head into pressure head, permitting turbine placement above tailrace level without losing effective head.
Last updated: August 2026
17.1 Hydroelectric, Thermal & Combined Cycle Power Plants
Power generation systems form the core of utility infrastructure and represent a vital major area on the PRC Registered Electrical Engineer (REE) Licensure Examination . Electrical power engineers must master the fundamental mechanical-to-electrical energy conversion principles, thermodynamic cycles, component functions, and mathematical formulations governing hydroelectric stations, thermal fossil-fueled plants, gas turbines, and combined cycle facilities.
1. Hydroelectric Power Generation Systems
Hydroelectric power plants convert the potential energy of elevated water into kinetic energy, then into rotational mechanical energy via hydraulic turbines, and finally into electrical energy via synchronous generators.
Fundamental Power Output Equation
Consider water flowing from a reservoir through a penstock at volumetric flow rate Q Q Q (cubic meters per second, m 3 / s \text{m}^3/\text{s} m 3 / s ) under effective net head H H H (meters, m \text{m} m ). The theoretical mechanical power available in the water stream is: P theoretical = ρ ⋅ g ⋅ Q ⋅ H ( Watts, W ) P_{\text{theoretical}} = \rho \cdot g \cdot Q \cdot H \quad (\text{Watts, W}) P theoretical = ρ ⋅ g ⋅ Q ⋅ H ( Watts, W )
where:
- ρ \rho ρ = density of water ( 1000 kg/m 3 1000\ \text{kg/m}^3 1000 kg/m 3 at standard conditions)
- g g g = acceleration due to gravity ( 9.81 m/s 2 9.81\ \text{m/s}^2 9.81 m/s 2 )
- Q Q Q = volumetric flow rate ( m 3 / s \text{m}^3/\text{s} m 3 / s )
H H H = net effective hydraulic head ( m \text{m} m ) = Gross Head ( H g H_g H g ) minus friction head losses ( h f h_f h f )
Accounting for turbine hydraulic efficiency η t \eta_t η t and generator electromechanical efficiency η g \eta_g η g , the net output electrical power P e P_e P e in kilowatts (kW) or megawatts (MW) is: P e = 1000 × 9.81 × Q × H × η t × η g 1000 = 9.81 ⋅ Q ⋅ H ⋅ η overall ( kW ) P_e = \frac{1000 \times 9.81 \times Q \times H \times \eta_t \times \eta_g}{1000} = 9.81 \cdot Q \cdot H \cdot \eta_{\text{overall}} \quad (\text{kW}) P e = 1000 1000 × 9.81 × Q × H × η t × η g = 9.81 ⋅ Q ⋅ H ⋅ η overall ( kW ) P e = 0.00981 ⋅ Q ⋅ H ⋅ η overall ( MW ) P_e = 0.00981 \cdot Q \cdot H \cdot \eta_{\text{overall}} \quad (\text{MW}) P e = 0.00981 ⋅ Q ⋅ H ⋅ η overall ( MW )
where η overall = η t × η g \eta_{\text{overall}} = \eta_t \times \eta_g η overall = η t × η g .
Penstock Head Losses (Manning & Darcy-Weisbach Equations)
The head loss h f h_f h f due to friction inside a cylindrical penstock of length L L L (m) and diameter D D D (m) with water velocity v = 4 Q π D 2 v = \frac{4 Q}{\pi D^2} v = π D 2 4 Q is evaluated using the Darcy-Weisbach equation : h f = f ⋅ L D ⋅ v 2 2 g h_f = f \cdot \frac{L}{D} \cdot \frac{v^2}{2 g} h f = f ⋅ D L ⋅ 2 g v 2
where f f f is the dimensionless Darcy friction factor.
2. Classification of Hydraulic Turbines
Hydraulic turbines are classified into impulse turbines and reaction turbines based on the action of water on the runner blades, or by operating head and specific speed N s N_s N s .
Specific Speed ( N s N_s N s )
The specific speed of a hydraulic turbine is defined as the rotational speed (in rpm) at which a geometrically similar turbine would run if it were scaled to produce 1 metric horsepower ( 0.7355 kW 0.7355\ \text{kW} 0.7355 kW ) under a unit head of 1 meter: N s = N P H 5 / 4 N_s = \frac{N \sqrt{P}}{H^{5/4}} N s = H 5/4 N P
where:
- N N N = actual rotational speed in rpm
- P P P = turbine output power in metric HP or kW (standard metric HP in classical PRC board formulas)
- H H H = effective net head in meters
- Hydraulic Turbine Types & Operational Parameters
Turbine Type Operating Principle Net Head Range ( H H H ) Flow Direction Specific Speed ( N s N_s N s , rpm) Key Characteristics & Features
Pelton Wheel Impulse High Head ( > 300 m > 300\ \text{m} > 300 m ) Tangential Jet 10 – 50 10\text{--}50 10 – 50 (Single nozzle); Up to 150 150 150 (Multi-nozzle) Water potential energy converted entirely to kinetic energy via high-velocity nozzles. Spear/needle valves regulate flow. Buckets split jet in half. Operates at atmospheric pressure.
Francis Turbine Reaction Medium Head ( 30 – 300 m 30\text{--}300\ \text{m} 30 – 300 m ) Radial Inflow to Axial Exit (Mixed Flow) 50 – 350 50\text{--}350 50 – 350 Water fills enclosed spiral casing under pressure. Adjustable wicket gates (guide vanes) regulate flow. Requires draft tube to recover velocity head.
Kaplan Turbine Reaction Low Head ( < 30 m < 30\ \text{m} < 30 m ) Axial Flow 300 – 1000 300\text{--}1000 300 – 1000 Propeller-type turbine with automatically adjustable runner blades and wicket gates (double regulation). Maintains high efficiency across wide load variations.
3. Essential Hydroelectric Auxiliary Components HYDROELECTRIC STATION SCHEMATIC & SURGE TANK
- Reservoir Surge Tank
- ~~~~~~~~~ ||
- | | ||
- | Water |========= Intake ======\ ||
- | Level | \\ ||
- ~~~~~~~~~ \\ Penstock ||
- \\==============================||=======\
- \\ Valve / Governor
- \\ +----------+
- \\--| Turbine |
- +----------+
- | Draft Tube
- v Tailrace
- Surge Tanks
A surge tank is an open standpipe or storage reservoir connected to the conduit between the high-pressure penstock and the turbine casing.
Water Hammer Relief: When electrical load drops suddenly, the governor rapidly closes the turbine inlet valves. The immense momentum of water in the long penstock generates extreme hydraulic shock waves ( water hammer ). The surge tank allows water to rise freely, absorbing the excess pressure surge and preventing penstock rupture.
Storage Buffer during Load Acceptance: When load increases suddenly, the surge tank supplies immediate additional water to the turbine while the main water column in the penstock accelerates.
Draft Tubes
A draft tube is an airtight diverging conduit connecting the runner outlet of a reaction turbine (Francis or Kaplan) to the tailrace channel.
Kinetic Energy Recovery: Water leaves the runner with significant kinetic energy ( v 2 2 2 g \frac{v_2^2}{2g} 2 g v 2 2 ). The expanding cross-sectional area of the draft tube decreases water velocity ( v 3 < v 2 v_3 < v_2 v 3 < v 2 ), converting velocity head into pressure head in accordance with Bernoulli's theorem: Δ h recovered = v 2 2 − v 3 2 2 g − h f , draft \Delta h_{\text{recovered}} = \frac{v_2^2 - v_3^2}{2g} - h_{f,\text{draft}} Δ h recovered = 2 g v 2 2 − v 3 2 − h f , draft
Head Preservation: Allows the turbine runner to be installed above the tailrace water level for inspection and maintenance without sacrificing effective net head.
4. Thermal Power Plants (Steam / Rankine Cycle)
Fossil-fueled thermal power stations convert chemical energy in fuel (coal, heavy fuel oil, or natural gas) into thermal energy via combustion, generating high-pressure, high-temperature steam that expands in a steam turbine to drive a synchronous generator.
The Standard Ideal Rankine Cycle
The fundamental thermodynamic cycle governing steam power plants comprises four main processes: STEAM POWER PLANT RANKINE CYCLE
- +--------------+ High-Temp Steam +-----------------+
- | Boiler / |========================>| Steam Turbine |----
- | Superheater | +-----------------+ |
- +--------------+ | |
- ^ | Exhaust | Work Output
- | Feedwater v Steam v (Generator)
- +--------------+ Low-Temp Water +-----------------+
- | Feed Pump |<========================| Condenser |
- +--------------+ +-----------------+
Process 1--2 (Isentropic Expansion): High-pressure superheated steam expands through high-pressure (HP), intermediate-pressure (IP), and low-pressure (LP) turbine stages, performing mechanical shaft work W t = h 1 − h 2 W_t = h_1 - h_2 W t = h 1 − h 2 .
Process 2--3 (Isobaric Condensation): Wet exhaust steam passes into the condenser, rejecting heat Q out = h 2 − h 3 Q_{\text{out}} = h_2 - h_3 Q out = h 2 − h 3 to cooling water, condensing into saturated liquid water.
Process 3--4 (Isentropic Compression): Boiler feed pumps (BFP) elevate liquid water pressure to boiler drum pressure, requiring pump work input W p = h 4 − h 3 = v f ( P 4 − P 3 ) W_p = h_4 - h_3 = v_f (P_4 - P_3) W p = h 4 − h 3 = v f ( P 4 − P 3 ) .
Process 4--1 (Isobaric Heat Addition): Water passes through economizers, steam drum, boiler tubes, and superheaters, absorbing heat Q in = h 1 − h 4 Q_{\text{in}} = h_1 - h_4 Q in = h 1 − h 4 from combustion flue gases.
Rankine Cycle Efficiency Equations Thermal Efficiency: η Rankine = W net Q in = W t − W p Q in = ( h 1 − h 2 ) − ( h 4 − h 3 ) h 1 − h 4 \text{Thermal Efficiency: } \eta_{\text{Rankine}} = \frac{W_{\text{net}}}{Q_{\text{in}}} = \frac{W_t - W_p}{Q_{\text{in}}} = \frac{(h_1 - h_2) - (h_4 - h_3)}{h_1 - h_4} Thermal Efficiency: η Rankine = Q in W net = Q in W t − W p = h 1 − h 4 ( h 1 − h 2 ) − ( h 4 − h 3 )
Since feed pump work W p W_p W p is typically small ( < 1 % – 2 % < 1\%\text{--}2\% < 1% – 2% of W t W_t W t ), the approximate thermodynamic efficiency is: η Rankine ≈ h 1 − h 2 h 1 − h f 4 \eta_{\text{Rankine}} \approx \frac{h_1 - h_2}{h_1 - h_{f4}} η Rankine ≈ h 1 − h f 4 h 1 − h 2
Station Overall Thermal Efficiency ( η overall \eta_{\text{overall}} η overall )
Overall station efficiency factors in thermal, mechanical, electrical, and auxiliary energy conversion losses: η overall = η boiler × η thermal × η generator × η auxiliary \eta_{\text{overall}} = \eta_{\text{boiler}} \times \eta_{\text{thermal}} \times \eta_{\text{generator}} \times \eta_{\text{auxiliary}} η overall = η boiler × η thermal × η generator × η auxiliary
Typical coal-fired power station overall efficiencies range from 32 % 32\% 32% to 40 % 40\% 40% (up to 45 % 45\% 45% for ultra-supercritical steam boilers operating above 22.1 MPa 22.1\ \text{MPa} 22.1 MPa and 600 ∘ C 600^\circ\text{C} 60 0 ∘ C ).
Efficiency Enhancement Auxiliaries
Superheater: Elevates steam temperature above saturation level at constant pressure. Eliminates moisture droplets during expansion, protecting turbine blades from erosion while increasing Carnot cycle efficiency.
Reheater: Returns partially expanded steam from the HP turbine back to the boiler to reheat it to high temperature before sending it into IP/LP turbine stages. Increases work output and steam dryness at turbine exit.
Economizer: A heat exchanger located in the boiler flue gas duct that preheats boiler feed water using residual heat from exhaust gases before entering the steam drum, reducing fuel consumption by 5 % – 10 % 5\%\text{--}10\% 5% – 10% .
Air Preheater (APH): Preheats incoming combustion air using low-temperature flue gas exiting the economizer. Improves boiler combustion efficiency and furnace temperature.
- 5. Gas Turbines (Brayton Cycle) & Combined Cycle Systems (CCGT)
- Open-Cycle Gas Turbines (Brayton Cycle)
Gas turbine units operate on the thermodynamic Brayton Cycle , consisting of:
Isentropic compression of ambient air in a multi-stage axial compressor.
Isobaric combustion of fuel (natural gas or distillate diesel) in a combustion chamber.
Isentropic expansion of high-temperature combustion gases ( 1100 ∘ C– 1400 ∘ C 1100^\circ\text{C}\text{--}1400^\circ\text{C} 110 0 ∘ C – 140 0 ∘ C ) through the gas turbine.
Ideal Brayton cycle thermal efficiency depends strictly on the pressure ratio r p = P 2 P 1 r_p = \frac{P_2}{P_1} r p = P 1 P 2 : η Brayton = 1 − 1 r p ( γ − 1 ) / γ \eta_{\text{Brayton}} = 1 - \frac{1}{r_p^{(\gamma - 1)/\gamma}} η Brayton = 1 − r p ( γ − 1 ) / γ 1
where γ = C p C v ≈ 1.4 \gamma = \frac{C_p}{C_v} \approx 1.4 γ = C v C p ≈ 1.4 for air.
Operating Characteristic: Open-cycle gas turbines feature low capital cost and extremely fast start-up capability ( 5 – 15 5\text{--}15 5 – 15 minutes to full load), making them ideal for peaking duty , but their efficiency is modest ( 28 % – 38 % 28\%\text{--}38\% 28% – 38% ).
Combined Cycle Gas Turbine (CCGT) Systems
CCGT power plants combine the high-temperature open Brayton cycle gas turbine with a low-temperature Rankine steam cycle using a Heat Recovery Steam Generator (HRSG) . COMBINED CYCLE POWER PLANT (CCGT) TOPOLOGY
- Air --> [Compressor] --> [Combustor] --> [Gas Turbine] --> Generator (2/3 Power)
- |
- Hot Exhaust Gas (~600°C)
- v
- +-----------------+
- | HRSG Unit |
- +-----------------+
- |
- Superheated Steam
- v
- [Steam Turbine] --> Generator (1/3 Power)
- |
- [Condenser]
- CCGT Thermal Efficiency
Let η 1 \eta_1 η 1 be the thermal efficiency of the gas turbine topping cycle and η 2 \eta_2 η 2 be the thermal efficiency of the steam bottoming cycle. The combined cycle overall efficiency η cc \eta_{\text{cc}} η cc is: η cc = η 1 + η 2 ( 1 − η 1 ) \eta_{\text{cc}} = \eta_1 + \eta_2 (1 - \eta_1) η cc = η 1 + η 2 ( 1 − η 1 )
Modern CCGT power plants achieve overall thermal efficiencies between 55 % 55\% 55% and 63 % 63\% 63% , representing the most efficient fossil-fuel generation technology available.
- Solved Board Exam Examples
- Example 1: Hydroelectric Power & Flow Calculation
Problem: A hydroelectric power station operates under an effective net head of 120 m 120\ \text{m} 120 m with a water discharge rate of 25 m 3 / s 25\ \text{m}^3/\text{s} 25 m 3 / s . The hydraulic turbine efficiency is 90 % 90\% 90% and the synchronous generator efficiency is 95 % 95\% 95% . Calculate: (a) Total overall plant efficiency, and (b) Net electrical power output delivered to the grid in MW.
Solution:
Compute overall plant efficiency: η overall = η t × η g = 0.90 × 0.95 = 0.855 ( 85.5 % ) \eta_{\text{overall}} = \eta_t \times \eta_g = 0.90 \times 0.95 = 0.855 \quad (85.5\%) η overall = η t × η g = 0.90 × 0.95 = 0.855 ( 85.5% )
Calculate electric power output using P e = 9.81 ⋅ Q ⋅ H ⋅ η overall P_e = 9.81 \cdot Q \cdot H \cdot \eta_{\text{overall}} P e = 9.81 ⋅ Q ⋅ H ⋅ η overall : P e = 9.81 × 25 m 3 / s × 120 m × 0.855 = 25 , 162.05 kW P_e = 9.81 \times 25\ \text{m}^3/\text{s} \times 120\ \text{m} \times 0.855 = 25,162.05\ \text{kW} P e = 9.81 × 25 m 3 / s × 120 m × 0.855 = 25 , 162.05 kW
Convert to megawatts: P e = 25 , 162.05 1000 = 25.16 MW P_e = \frac{25,162.05}{1000} = 25.16\ \text{MW} P e = 1000 25 , 162.05 = 25.16 MW
Example 2: Thermal Steam Station Coal Consumption & Efficiency
Problem: A 100 MW 100\ \text{MW} 100 MW coal-fired steam power station burns coal with a higher heating value (HHV) of 28 , 000 kJ/kg 28,000\ \text{kJ/kg} 28 , 000 kJ/kg at a rate of 45 metric tons 45\ \text{metric tons} 45 metric tons per hour. Determine: (a) Total thermal heat input rate in MW, (b) Station overall thermal efficiency, and (c) Station heat rate in kJ/kWh \text{kJ/kWh} kJ/kWh .
Solution:
Convert coal consumption rate to kg/s: m ˙ fuel = 45 , 000 kg/h 3600 s/h = 12.5 kg/s \dot{m}_{\text{fuel}} = \frac{45,000\ \text{kg/h}}{3600\ \text{s/h}} = 12.5\ \text{kg/s} m ˙ fuel = 3600 s/h 45 , 000 kg/h = 12.5 kg/s
Compute total thermal heat input rate Q in Q_{\text{in}} Q in : Q in = 12.5 kg/s × 28 , 000 kJ/kg = 350 , 000 kJ/s = 350 , 000 kW = 350 MW th Q_{\text{in}} = 12.5\ \text{kg/s} \times 28,000\ \text{kJ/kg} = 350,000\ \text{kJ/s} = 350,000\ \text{kW} = 350\ \text{MW}_{\text{th}} Q in = 12.5 kg/s × 28 , 000 kJ/kg = 350 , 000 kJ/s = 350 , 000 kW = 350 MW th
Calculate overall plant thermal efficiency: η overall = P electrical Q in × 100 % = 100 MW el 350 MW th × 100 % = 28.57 % \eta_{\text{overall}} = \frac{P_{\text{electrical}}}{Q_{\text{in}}} \times 100\% = \frac{100\ \text{MW}_{\text{el}}}{350\ \text{MW}_{\text{th}}} \times 100\% = 28.57\% η overall = Q in P electrical × 100% = 350 MW th 100 MW el × 100% = 28.57%
Calculate station heat rate: Heat Rate = 3600 η overall = 3600 0.285714 = 12 , 600 kJ/kWh \text{Heat Rate} = \frac{3600}{\eta_{\text{overall}}} = \frac{3600}{0.285714} = 12,600\ \text{kJ/kWh} Heat Rate = η overall 3600 = 0.285714 3600 = 12 , 600 kJ/kWh