Study guide

15.3 DC Generators & DC Motors

PRC Registered Electrical Engineer REE

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Overview, RA 7920 & Electrical Engineering Ethics

1.1 PRC Board of Electrical Engineering & REE Examination Overview 1.2 Republic Act No. 7920 (New Electrical Engineering Law) & License Classes 1.3 Code of Ethics & Professional Practice for Electrical Engineers

2 Chapter 2: Math — Algebra, Trig & Geometry

2.1 Algebraic Equations, Polynomials & Complex Numbers 2.2 Trigonometry — Identities, Triangles & Spherical Trig 2.3 Analytic & Solid Geometry

3 Chapter 3: Engineering Mathematics — Calculus & Differential Equations

3.1 Differential Calculus, Limits, Derivatives & Applications 3.2 Integral Calculus, Integration Techniques & Area/Volume Applications 3.3 Ordinary Differential Equations & Initial-Value Problems

4 Chapter 4: Engineering Mathematics — Advanced Math & Transform Methods

4.1 Laplace Transforms, Inverse Transforms & Circuit Applications 4.2 Fourier Series, Fourier Transforms & Frequency-Domain Analysis 4.3 Vector Analysis, Linear Algebra, Matrices & Complex Analysis

5 Chapter 5: Engineering Mathematics — Probability, Statistics & Engineering Data Analysis

5.1 Probability Theory, Counting Techniques & Bayes' Theorem 5.2 Engineering Data Analysis I — Descriptive Statistics & Probability Distributions 5.3 Engineering Data Analysis II — Confidence Intervals, Hypothesis Testing & Regression

6 Chapter 6: Engineering Mathematics — Numerical Methods & Analysis

6.1 Numerical Root-Finding & Solution of Linear Systems 6.2 Interpolation, Numerical Integration & Numerical Solution of ODEs

7 Chapter 7: ESAS — Physics, Chemistry & Computer Fundamentals

7.1 Physics for Engineers 7.2 General Chemistry & Materials Science 7.3 Computer Fundamentals, Programming & Data Logic 7.4 Logic Circuits, Switching Theory & Microprocessor Systems

8 Chapter 8: ESAS — Mechanics & Thermal-Fluid Engineering

8.1 Engineering Mechanics — Statics & Dynamics 8.2 Strength of Materials & Mechanics of Deformable Bodies 8.3 Thermal-Fluid Engineering — Thermodynamics & Fluid Mechanics

9 Chapter 9: ESAS — Engineering Economics, Management & Contracts

9.1 Engineering Economics & Depreciation 9.2 Engineering Management & Ethics 9.3 Philippine Electrical Engineering Law, Code & Contracts 9.4 Technopreneurship 101 & Management of Engineering Projects

10 Chapter 10: PEC 1 — Safety, Sizing & Protection

10.1 PEC Fundamentals, Safety Standards & Grounding/Bonding 10.2 Conductor Sizing, Ampacity Adjustment & Voltage Drop 10.3 Overcurrent Protection, Branch Circuit & Feeder Sizing 10.4 Basic Occupational Safety & Health (BOSH) and Electrical Safety Standards

11 Chapter 11: PEC 1 & 2 — Equipment & Utility Systems

11.1 PEC Equipment Installation & Wiring Methods 11.2 Utility Systems, Transformers & Switchgear 11.3 Special Occupancies & Hazardous Locations

12 Chapter 12: Electrical Professional — DC & AC Circuit Fundamentals

12.1 DC Circuit Analysis & Network Theorems 12.2 Single-Phase AC Circuits & Phasor Analysis 12.3 Balanced & Unbalanced Three-Phase AC Circuits

13 Chapter 13: Electrical Professional — EM Fields & Transients

13.1 Electrostatics, Magnetostatics & Maxwell's Equations 13.2 Electromagnetic Waves & Transmission Line Fields 13.3 First-Order & Second-Order Circuit Transients

14 Chapter 14: Electrical Professional — Electronics, Industrial Electronics & Communications

14.1 Electronics 1 & 2 — Semiconductor Devices & Analog Circuits 14.2 Electrical Apparatus & Devices — Industrial Electronics & Power Converters 14.3 Fundamentals of Electronic Communications

15 Chapter 15: Electrical Professional — Transformers & DC Machines

15.1 Single-Phase & Three-Phase Transformers 15.2 Transformer Connections & Special Transformers 15.3 DC Generators & DC Motors

16 Chapter 16: Electrical Professional — AC Synchronous & Induction Machinery

16.1 Synchronous Generators (Alternators) 16.2 Synchronous Motors & Special AC Machines 16.3 Three-Phase & Single-Phase Induction Motors

17 Chapter 17: Electrical Professional — Power Plants & Energy Conversion

17.1 Hydroelectric, Thermal & Combined Cycle Power Plants 17.2 Renewable Energy Systems & Geothermal Power Plants 17.3 Power Plant Economics, Load Curves & Energy Conversion

18 Chapter 18: Electrical Professional — Transmission & Distribution

18.1 Transmission Line Parameters & Performance Models 18.2 Mechanical Overhead Line Design, Underground Cables & Insulators 18.3 Distribution Systems, Substation Layouts & Power Flow Control

19 Chapter 19: Electrical Professional — Power System Analysis

19.1 The Per-Unit System, Base Conversion & Impedance Diagrams 19.2 Symmetrical Components & Unbalanced Fault Analysis 19.3 Load Flow, Economic Dispatch & Power System Stability

20 Chapter 20: Electrical Professional — Protection, Control, Instrumentation & Illumination

20.1 Power System Protection & Protective Relaying 20.2 Industrial Motor Control, Logic Circuits & PLC Automation 20.3 Electrical Instrumentation, Transducers & Measurement Systems 20.4 Illumination Engineering, Lighting Design & Photometrics 20.5 Feedback Control Systems & Research Methods

15.3 DC Generators & DC Motors

Key Takeaways Explain This Topic AI

The generated EMF equation in a DC machine armature is E g = P Φ Z N 60 a E_g = \frac{P \Phi Z N}{60 a} E g ​ = 60 a P Φ ZN ​ , where simplex lap windings provide a = P a = P a = P parallel paths (high current) and simplex wave windings provide a = 2 a = 2 a = 2 parallel paths (high voltage).

Electromagnetic torque developed in a DC motor armature is T e = P Φ Z I a 2 π a = 0.159 ( P Z a ) Φ I a T_e = \frac{P \Phi Z I_a}{2 \pi a} = 0.159 \left(\frac{P Z}{a}\right) \Phi I_a T e ​ = 2 πa P Φ Z I a ​ ​ = 0.159 ( a PZ ​ ) Φ I a ​ , showing direct proportionality to air-gap flux and armature current.

Self-excited DC shunt generators require residual magnetism, field circuit resistance below critical resistance ( R f < R c R_f < R_c R f ​ < R c ​ ), and proper field winding polarity to successfully build up voltage.

Speed control follows N = k V t − I a R a Φ N = k \frac{V_t - I_a R_a}{\Phi} N = k Φ V t ​ − I a ​ R a ​ ​ : field flux weakening provides speed control above base speed, while armature voltage control (Ward-Leonard) provides smooth speed control below base speed.

DC series motors develop starting torque proportional to the square of armature current ( T ∝ I a 2 T \propto I_a^2 T ∝ I a 2 ​ ) and must never be started under no-load conditions to prevent destructive speed runaway ( N → ∞ N \to \infty N → ∞ ).

Last updated: August 2026

  • 15.3 DC Generators & DC Motors
  • Mechanical Construction & Commutator Operation

Direct Current (DC) machines operate as electro-mechanical energy converters. A DC generator converts mechanical energy into DC electrical power, whereas a DC motor converts DC electrical energy into mechanical rotation. Mechanically, DC generators and DC motors are structurally identical and fully reversible. CROSS-SECTIONAL VIEW OF A 4-POLE DC MACHINE

  • Stator Frame (Yoke)
  • ┌───────────┐
  • ───│ N-Pole │───
  • / └─────┬─────┘ \
  • / │ \
  • ┌───────┐ ┌───▼───┐ ┌───────┐
  • │S-Pole │◄─────┤Rotor ├─────►│S-Pole │
  • └───────┘ └───▲───┐ └───────┘
  • \ │ /
  • \ ┌─────┴─────┐ /
  • ───│ N-Pole │───
  • └───────────┘
  • Primary Mechanical Components

Yoke (Stator Frame) : Outer cast steel or fabricated steel ring providing structural support and carrying the magnetic flux return path.

Field Poles & Field Coils : Main poles constructed of laminated steel punchings fitted with pole shoes to distribute air-gap flux uniformly. Field coils wound around pole cores produce main excitation flux Φ \Phi Φ .

Interpoles (Commutating Poles) : Small narrow poles placed on the magnetic neutral axis (MNA) between main poles. Connected in series with the armature to neutralize armature reaction and prevent destructive brush sparking.

Armature Core : Cylindrical rotor assembled from insulated high-grade silicon steel laminations containing longitudinal slots for armature conductors. Lamination minimizes core eddy current loss.

Armature Winding : Insulated copper conductors placed in rotor slots where main EMF is induced.

Commutator : Cylindrical assembly of hard-drawn wedge-shaped copper segments insulated from each other by high-grade mica sheets ( 0.6 mm − 0.8 mm 0.6\text{ mm} - 0.8\text{ mm} 0.6 mm − 0.8 mm thick). Acts as a mechanical rectifier converting internal AC EMF into unidirectional DC terminal voltage.

Brushes & Brush-Holders : Electro-graphitic or carbon brushes held against the rotating commutator by springs to collect current for external circuits.

Armature Winding Topologies: Lap Winding vs. Wave Winding

Armature coils are interconnected in two distinct winding configurations:

Winding Characteristic Simplex Lap Winding Simplex Wave Winding

Coil Termination Coil ends connected to adjacent commutator segments ( Y b − Y f = ± 2 Y_b - Y_f = \pm 2 Y b ​ − Y f ​ = ± 2 ) Coil ends connected to commutator segments far apart ( Y b + Y f = 2 C ± 1 P Y_b + Y_f = 2 \frac{C \pm 1}{P} Y b ​ + Y f ​ = 2 P C ± 1 ​ )

Parallel Paths ( a a a ) Equal to number of main poles: a = P ⋅ m a = P \cdot m a = P ⋅ m Always equal to two: a = 2 ⋅ m a = 2 \cdot m a = 2 ⋅ m (independent of poles)

Voltage & Current Rating High-Current, Low-Voltage applications High-Voltage, Low-Current applications

Equalizer Rings Required to equalize unbalance currents caused by unequal pole fluxes Not required (conductors pass under all poles in series)

  • Dummy Coils Not required Used occasionally to maintain mechanical rotor balance
  • Fundamental Derivation of EMF & Torque Equations
  • 1. RMS/Average Generated EMF Equation ( E g E_g E g ​ )

Let:

  • P P P = number of main magnetic poles
  • Φ \Phi Φ = magnetic flux per pole in Webers (Wb)
  • Z Z Z = total number of active armature conductors
  • N N N = rotor speed in revolutions per minute (RPM)
  • a a a = number of parallel paths ( a = P a = P a = P for lap, a = 2 a = 2 a = 2 for wave)

In one complete revolution ( 60 / N 60 / N 60/ N seconds), a single armature conductor cuts a total magnetic flux of P Φ P \Phi P Φ Webers. By Faraday's law, average EMF induced per conductor is: ≠ avg = d Φ d t = P Φ 60 N = P Φ N 60 Volts \ne_{\text{avg}} = \frac{d\Phi}{dt} = \frac{P \Phi}{\frac{60}{N}} = \frac{P \Phi N}{60} \quad \text{Volts}  = avg ​ = d t d Φ ​ = N 60 ​ P Φ ​ = 60 P Φ N ​ Volts

Since Z Z Z total conductors are divided into a a a parallel paths, the number of conductors connected in series per path is Z a \frac{Z}{a} a Z ​ . The total Armature Generated EMF ( E g E_g E g ​ ) is: E g = P Φ Z N 60 a E_g = \frac{P \Phi Z N}{60 a} E g ​ = 60 a P Φ ZN ​

2. Electromagnetic Torque Equation ( T e T_e T e ​ )

Total mechanical power developed in the armature equals total converted electrical power: P mech = T e ω m = T e ( 2 π N 60 ) = E g I a P_{\text{mech}} = T_e \omega_m = T_e \left( \frac{2 \pi N}{60} \right) = E_g I_a P mech ​ = T e ​ ω m ​ = T e ​ ( 60 2 π N ​ ) = E g ​ I a ​

Substituting E g = P Φ Z N 60 a E_g = \frac{P \Phi Z N}{60 a} E g ​ = 60 a P Φ ZN ​ into the power equality: T e ( 2 π N 60 ) = ( P Φ Z N 60 a ) I a T_e \left( \frac{2 \pi N}{60} \right) = \left( \frac{P \Phi Z N}{60 a} \right) I_a T e ​ ( 60 2 π N ​ ) = ( 60 a P Φ ZN ​ ) I a ​

Solving for Electromagnetic Developed Torque ( T e T_e T e ​ ) : T e = P Φ Z I a 2 π a = ( 1 2 π ) ( P Z a ) Φ I a = 0.159 ( P Z a ) Φ I a ( N ⋅ m ) T_e = \frac{P \Phi Z I_a}{2 \pi a} = \left( \frac{1}{2\pi} \right) \left( \frac{P Z}{a} \right) \Phi I_a = 0.159 \left( \frac{P Z}{a} \right) \Phi I_a \quad (\text{N}\cdot\text{m}) T e ​ = 2 πa P Φ Z I a ​ ​ = ( 2 π 1 ​ ) ( a PZ ​ ) Φ I a ​ = 0.159 ( a PZ ​ ) Φ I a ​ ( N ⋅ m )

  • DC Generator Classification & Voltage Buildup Requirements
  • DC generators are classified by their field excitation methods: DC GENERATOR SCHEMATIC CLASSIFICATIONS
  • SEPARATELY EXCITED SHUNT GENERATOR SERIES GENERATOR
  • ┌───────────┐ ┌──────┬──────┐ ┌───█████───┬───┐
  • Ext.DC █ Field Coil│ │ │ │ │ Series │ │
  • Source └───────────┘ ┌─┴─┐ ███ │ ┌─┴─┐ Field │ ███ Load
  • ┌───────────┐ │ G │ ███ Rf ███ Load │ G │ ███
  • │ Armature ├─► V_t └─┬─┘ │ ███ └─┬─┘ │
  • └───────────┘ └──────┴──────┘ └───────────┴───┘
  • Governing Terminal Equations

Shunt Generator : Field winding connected in parallel across armature ( I a = I L + I f I_a = I_L + I_f I a ​ = I L ​ + I f ​ , I f = V t R f I_f = \frac{V_t}{R_f} I f ​ = R f ​ V t ​ ​ ). V t = E g − I a R a V_t = E_g - I_a R_a V t ​ = E g ​ − I a ​ R a ​

Series Generator : Field winding connected in series with armature ( I a = I s = I L I_a = I_s = I_L I a ​ = I s ​ = I L ​ ). V t = E g − I a ( R a + R s ) V_t = E_g - I_a(R_a + R_s) V t ​ = E g ​ − I a ​ ( R a ​ + R s ​ )

Compound Generator : Contains both shunt and series field windings.

Cumulative Compounding : Series field flux aids shunt field flux ( Φ total = Φ f + Φ s \Phi_{\text{total}} = \Phi_f + \Phi_s Φ total ​ = Φ f ​ + Φ s ​ ). Can be over-compounded, flat-compounded, or under-compounded to compensate for line drop.

Differential Compounding : Series field flux opposes shunt field flux ( Φ total = Φ f − Φ s \Phi_{\text{total}} = \Phi_f - \Phi_s Φ total ​ = Φ f ​ − Φ s ​ ). Used in specialized arc welding generators.

Long-Shunt vs. Short-Shunt : In long-shunt, shunt field is connected across both armature and series field ( I f = V t / R f I_f = V_t / R_f I f ​ = V t ​ / R f ​ ). In short-shunt, shunt field is connected across armature directly ( I f = ( V t + I a R s ) / R f I_f = (V_t + I_a R_s)/R_f I f ​ = ( V t ​ + I a ​ R s ​ ) / R f ​ ).

Conditions for Self-Excited Voltage Buildup in Shunt Generators

To successfully build up terminal voltage from zero, a self-excited DC shunt generator must fulfill three statutory conditions:

Presence of Residual Magnetism : The iron pole cores must retain a small residual magnetic flux (yielding residual voltage E res ≈ 2 % − 5 % E_{\text{res}} \approx 2\% - 5\% E res ​ ≈ 2% − 5% of rated V t V_t V t ​ ).

Field Resistance Below Critical Resistance ( R f < R c R_f < R_c R f ​ < R c ​ ) : The resistance of the shunt field circuit must be less than the critical field resistance slope ( R c R_c R c ​ ) tangent to the No-Load Magnetization Curve (OCC) at operating speed.

Proper Field Polarity & Rotation Direction : Field coils must be connected such that initial current driven by E res E_{\text{res}} E res ​ produces flux that aids residual flux. If connected backward, residual flux is destroyed and voltage drops to zero.

DC Motor Back-EMF & Speed Governing

When DC supply voltage V t V_t V t ​ is applied to a DC motor, armature conductors rotate through the main magnetic field, inducing a counter-EMF known as Back-EMF ( E b E_b E b ​ ) by Faraday's law: E b = P Φ Z N 60 a E_b = \frac{P \Phi Z N}{60 a} E b ​ = 60 a P Φ ZN ​

By Lenz's law, back-EMF opposes applied terminal voltage. Armature current is governed by: I a = V t − E b R a I_a = \frac{V_t - E_b}{R_a} I a ​ = R a ​ V t ​ − E b ​ ​

Mechanical Power Output Optimization

Multiplying by I a I_a I a ​ gives the electrical power balance: V t I a = E b I a + I a 2 R a ⟹ P in = P mech + P cu,armature V_t I_a = E_b I_a + I_a^2 R_a \implies P_{\text{in}} = P_{\text{mech}} + P_{\text{cu,armature}} V t ​ I a ​ = E b ​ I a ​ + I a 2 ​ R a ​ ⟹ P in ​ = P mech ​ + P cu,armature ​

Maximum mechanical power developed occurs when d P mech d I a = 0 \frac{d P_{\text{mech}}}{d I_a} = 0 d I a ​ d P mech ​ ​ = 0 , yielding: E b = V t 2 E_b = \frac{V_t}{2} E b ​ = 2 V t ​ ​

(At maximum mechanical power output, motor efficiency is 50%).

General DC Motor Speed Formula

Substituting E b = k Φ N E_b = k \Phi N E b ​ = k Φ N into the voltage equation yields the fundamental Speed Equation : N = 60 a E b P Φ Z = k ( V t − I a R a Φ ) N = \frac{60 a E_b}{P \Phi Z} = k \left( \frac{V_t - I_a R_a}{\Phi} \right) N = P Φ Z 60 a E b ​ ​ = k ( Φ V t ​ − I a ​ R a ​ ​ )

Speed Control Methods & Motor Starters

From N ∝ V t − I a R a Φ N \propto \frac{V_t - I_a R_a}{\Phi} N ∝ Φ V t ​ − I a ​ R a ​ ​ , motor speed is controlled via three methods: DC MOTOR SPEED CONTROL REGIONS & OPERATING LIMITS

  • Speed N ▲
  • │ Below Base Speed │ Above Base Speed
  • │ (Armature Voltage Control) │ (Field Flux Control)
  • │ Constant Torque Region │ Constant Power Region
  • Base Speed├────────────────────────────────┼─────────────────────────►
  • │ Power P ∝ N │ Power P = Constant
  • │ Torque T = Constant │ Torque T ∝ 1/N
  • └────────────────────────────────┴─────────────────────────►
  • Armature Voltage Vt
  • 1. Field Flux Control (Shunt Field Rheostat)

Inserting resistance in series with the shunt field reduces flux Φ \Phi Φ .

Since N ∝ 1 / Φ N \propto 1 / \Phi N ∝ 1/Φ , speed increases above rated base speed .

Provides constant kW, variable torque operation.

2. Armature Voltage Control (Ward-Leonard System / Variable DC Supply)

Varying applied armature voltage V t V_t V t ​ while maintaining constant field flux Φ \Phi Φ .

Speed varies linearly from zero up to rated base speed ( N ∝ V t N \propto V_t N ∝ V t ​ ).

Provides smooth speed control, constant torque operation, and regenerative braking.

3. Armature Resistance Control

Inserting external resistance R ext R_{\text{ext}} R ext ​ in series with armature circuit.

Reduces speed below base speed, but exhibits poor speed regulation and severe I 2 R I^2 R I 2 R power loss.

Motor Starters (3-Point and 4-Point Starters)

At standstill ( N = 0 N = 0 N = 0 ), back-EMF is zero ( E b = 0 E_b = 0 E b ​ = 0 ). If connected directly to line voltage, starting current would be dangerously high: I start = V t − 0 R a ≈ 10 − 20 × I full-load I_{\text{start}} = \frac{V_t - 0}{R_a} \approx 10 - 20 \times I_{\text{full-load}} I start ​ = R a ​ V t ​ − 0 ​ ≈ 10 − 20 × I full-load ​

To limit starting current, external resistance is inserted by a starter and cut out in steps as speed rises:

3-Point Starter : Contains No-Volt Release (NVR) coil connected in series with the shunt field. Disadvantage: high field resistance added for high-speed control weakens NVR magnet, causing handle trip.

4-Point Starter : Connects NVR coil in series with a protective resistor across full line voltage independently of shunt field, permitting wide field speed control.

DC Series Motor Performance & SAFETY MANDATE

In a DC series motor, field coils are in series with armature ( I a = I s I_a = I_s I a ​ = I s ​ , Φ ∝ I a \Phi \propto I_a Φ ∝ I a ​ below saturation). T e ∝ Φ I a ∝ I a 2 T_e \propto \Phi I_a \propto I_a^2 T e ​ ∝ Φ I a ​ ∝ I a 2 ​

DC series motors produce extremely high starting torque ( T ∝ I a 2 T \propto I_a^2 T ∝ I a 2 ​ ), making them ideal for heavy electric traction, trains, hoists, cranes, and elevators.

CRITICAL REE EXAM SAFETY MANDATE: NO-LOAD RUNAWAY HAZARD

Mandatory Safety Rule: A DC series motor must NEVER be started or operated without a mechanical load (never use belt drives; use direct gearing).

Physical Mechanism: At no-load, armature current drops to a tiny magnetizing value ( I a → 0 I_a \to 0 I a ​ → 0 ). Because series field flux is driven by armature current, flux collapses toward zero ( Φ → 0 \Phi \to 0 Φ → 0 ).

Consequence: From N ∝ E b Φ N \propto \frac{E_b}{\Phi} N ∝ Φ E b ​ ​ , as flux Φ → 0 \Phi \to 0 Φ → 0 , motor speed accelerates toward infinity ( N → ∞ N \to \infty N → ∞ ). The resulting extreme centrifugal force causes catastrophic mechanical destruction, hurling armature windings and commutator segments outward.

Loading diagram... DC Generator & Motor Application Architecture & Speed Control Decision Tree

DC Shunt Motor Speed (RPM) Characteristic Curve vs. Percentage Armature Load Current