Study guide
15.3 DC Generators & DC Motors
PRC Registered Electrical Engineer REE
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Overview, RA 7920 & Electrical Engineering Ethics
1.1 PRC Board of Electrical Engineering & REE Examination Overview 1.2 Republic Act No. 7920 (New Electrical Engineering Law) & License Classes 1.3 Code of Ethics & Professional Practice for Electrical Engineers
2 Chapter 2: Math — Algebra, Trig & Geometry
2.1 Algebraic Equations, Polynomials & Complex Numbers 2.2 Trigonometry — Identities, Triangles & Spherical Trig 2.3 Analytic & Solid Geometry
3 Chapter 3: Engineering Mathematics — Calculus & Differential Equations
3.1 Differential Calculus, Limits, Derivatives & Applications 3.2 Integral Calculus, Integration Techniques & Area/Volume Applications 3.3 Ordinary Differential Equations & Initial-Value Problems
4 Chapter 4: Engineering Mathematics — Advanced Math & Transform Methods
4.1 Laplace Transforms, Inverse Transforms & Circuit Applications 4.2 Fourier Series, Fourier Transforms & Frequency-Domain Analysis 4.3 Vector Analysis, Linear Algebra, Matrices & Complex Analysis
5 Chapter 5: Engineering Mathematics — Probability, Statistics & Engineering Data Analysis
5.1 Probability Theory, Counting Techniques & Bayes' Theorem 5.2 Engineering Data Analysis I — Descriptive Statistics & Probability Distributions 5.3 Engineering Data Analysis II — Confidence Intervals, Hypothesis Testing & Regression
6 Chapter 6: Engineering Mathematics — Numerical Methods & Analysis
6.1 Numerical Root-Finding & Solution of Linear Systems 6.2 Interpolation, Numerical Integration & Numerical Solution of ODEs
7 Chapter 7: ESAS — Physics, Chemistry & Computer Fundamentals
7.1 Physics for Engineers 7.2 General Chemistry & Materials Science 7.3 Computer Fundamentals, Programming & Data Logic 7.4 Logic Circuits, Switching Theory & Microprocessor Systems
8 Chapter 8: ESAS — Mechanics & Thermal-Fluid Engineering
8.1 Engineering Mechanics — Statics & Dynamics 8.2 Strength of Materials & Mechanics of Deformable Bodies 8.3 Thermal-Fluid Engineering — Thermodynamics & Fluid Mechanics
9 Chapter 9: ESAS — Engineering Economics, Management & Contracts
9.1 Engineering Economics & Depreciation 9.2 Engineering Management & Ethics 9.3 Philippine Electrical Engineering Law, Code & Contracts 9.4 Technopreneurship 101 & Management of Engineering Projects
10 Chapter 10: PEC 1 — Safety, Sizing & Protection
10.1 PEC Fundamentals, Safety Standards & Grounding/Bonding 10.2 Conductor Sizing, Ampacity Adjustment & Voltage Drop 10.3 Overcurrent Protection, Branch Circuit & Feeder Sizing 10.4 Basic Occupational Safety & Health (BOSH) and Electrical Safety Standards
11 Chapter 11: PEC 1 & 2 — Equipment & Utility Systems
11.1 PEC Equipment Installation & Wiring Methods 11.2 Utility Systems, Transformers & Switchgear 11.3 Special Occupancies & Hazardous Locations
12 Chapter 12: Electrical Professional — DC & AC Circuit Fundamentals
12.1 DC Circuit Analysis & Network Theorems 12.2 Single-Phase AC Circuits & Phasor Analysis 12.3 Balanced & Unbalanced Three-Phase AC Circuits
13 Chapter 13: Electrical Professional — EM Fields & Transients
13.1 Electrostatics, Magnetostatics & Maxwell's Equations 13.2 Electromagnetic Waves & Transmission Line Fields 13.3 First-Order & Second-Order Circuit Transients
14 Chapter 14: Electrical Professional — Electronics, Industrial Electronics & Communications
14.1 Electronics 1 & 2 — Semiconductor Devices & Analog Circuits 14.2 Electrical Apparatus & Devices — Industrial Electronics & Power Converters 14.3 Fundamentals of Electronic Communications
15 Chapter 15: Electrical Professional — Transformers & DC Machines
15.1 Single-Phase & Three-Phase Transformers 15.2 Transformer Connections & Special Transformers 15.3 DC Generators & DC Motors
16 Chapter 16: Electrical Professional — AC Synchronous & Induction Machinery
16.1 Synchronous Generators (Alternators) 16.2 Synchronous Motors & Special AC Machines 16.3 Three-Phase & Single-Phase Induction Motors
17 Chapter 17: Electrical Professional — Power Plants & Energy Conversion
17.1 Hydroelectric, Thermal & Combined Cycle Power Plants 17.2 Renewable Energy Systems & Geothermal Power Plants 17.3 Power Plant Economics, Load Curves & Energy Conversion
18 Chapter 18: Electrical Professional — Transmission & Distribution
18.1 Transmission Line Parameters & Performance Models 18.2 Mechanical Overhead Line Design, Underground Cables & Insulators 18.3 Distribution Systems, Substation Layouts & Power Flow Control
19 Chapter 19: Electrical Professional — Power System Analysis
19.1 The Per-Unit System, Base Conversion & Impedance Diagrams 19.2 Symmetrical Components & Unbalanced Fault Analysis 19.3 Load Flow, Economic Dispatch & Power System Stability
20 Chapter 20: Electrical Professional — Protection, Control, Instrumentation & Illumination
20.1 Power System Protection & Protective Relaying 20.2 Industrial Motor Control, Logic Circuits & PLC Automation 20.3 Electrical Instrumentation, Transducers & Measurement Systems 20.4 Illumination Engineering, Lighting Design & Photometrics 20.5 Feedback Control Systems & Research Methods
15.3 DC Generators & DC Motors
Key Takeaways Explain This Topic AI
The generated EMF equation in a DC machine armature is E g = P Φ Z N 60 a E_g = \frac{P \Phi Z N}{60 a} E g = 60 a P Φ ZN , where simplex lap windings provide a = P a = P a = P parallel paths (high current) and simplex wave windings provide a = 2 a = 2 a = 2 parallel paths (high voltage).
Electromagnetic torque developed in a DC motor armature is T e = P Φ Z I a 2 π a = 0.159 ( P Z a ) Φ I a T_e = \frac{P \Phi Z I_a}{2 \pi a} = 0.159 \left(\frac{P Z}{a}\right) \Phi I_a T e = 2 πa P Φ Z I a = 0.159 ( a PZ ) Φ I a , showing direct proportionality to air-gap flux and armature current.
Self-excited DC shunt generators require residual magnetism, field circuit resistance below critical resistance ( R f < R c R_f < R_c R f < R c ), and proper field winding polarity to successfully build up voltage.
Speed control follows N = k V t − I a R a Φ N = k \frac{V_t - I_a R_a}{\Phi} N = k Φ V t − I a R a : field flux weakening provides speed control above base speed, while armature voltage control (Ward-Leonard) provides smooth speed control below base speed.
DC series motors develop starting torque proportional to the square of armature current ( T ∝ I a 2 T \propto I_a^2 T ∝ I a 2 ) and must never be started under no-load conditions to prevent destructive speed runaway ( N → ∞ N \to \infty N → ∞ ).
Last updated: August 2026
- 15.3 DC Generators & DC Motors
- Mechanical Construction & Commutator Operation
Direct Current (DC) machines operate as electro-mechanical energy converters. A DC generator converts mechanical energy into DC electrical power, whereas a DC motor converts DC electrical energy into mechanical rotation. Mechanically, DC generators and DC motors are structurally identical and fully reversible. CROSS-SECTIONAL VIEW OF A 4-POLE DC MACHINE
- Stator Frame (Yoke)
- ┌───────────┐
- ───│ N-Pole │───
- / └─────┬─────┘ \
- / │ \
- ┌───────┐ ┌───▼───┐ ┌───────┐
- │S-Pole │◄─────┤Rotor ├─────►│S-Pole │
- └───────┘ └───▲───┐ └───────┘
- \ │ /
- \ ┌─────┴─────┐ /
- ───│ N-Pole │───
- └───────────┘
- Primary Mechanical Components
Yoke (Stator Frame) : Outer cast steel or fabricated steel ring providing structural support and carrying the magnetic flux return path.
Field Poles & Field Coils : Main poles constructed of laminated steel punchings fitted with pole shoes to distribute air-gap flux uniformly. Field coils wound around pole cores produce main excitation flux Φ \Phi Φ .
Interpoles (Commutating Poles) : Small narrow poles placed on the magnetic neutral axis (MNA) between main poles. Connected in series with the armature to neutralize armature reaction and prevent destructive brush sparking.
Armature Core : Cylindrical rotor assembled from insulated high-grade silicon steel laminations containing longitudinal slots for armature conductors. Lamination minimizes core eddy current loss.
Armature Winding : Insulated copper conductors placed in rotor slots where main EMF is induced.
Commutator : Cylindrical assembly of hard-drawn wedge-shaped copper segments insulated from each other by high-grade mica sheets ( 0.6 mm − 0.8 mm 0.6\text{ mm} - 0.8\text{ mm} 0.6 mm − 0.8 mm thick). Acts as a mechanical rectifier converting internal AC EMF into unidirectional DC terminal voltage.
Brushes & Brush-Holders : Electro-graphitic or carbon brushes held against the rotating commutator by springs to collect current for external circuits.
Armature Winding Topologies: Lap Winding vs. Wave Winding
Armature coils are interconnected in two distinct winding configurations:
Winding Characteristic Simplex Lap Winding Simplex Wave Winding
Coil Termination Coil ends connected to adjacent commutator segments ( Y b − Y f = ± 2 Y_b - Y_f = \pm 2 Y b − Y f = ± 2 ) Coil ends connected to commutator segments far apart ( Y b + Y f = 2 C ± 1 P Y_b + Y_f = 2 \frac{C \pm 1}{P} Y b + Y f = 2 P C ± 1 )
Parallel Paths ( a a a ) Equal to number of main poles: a = P ⋅ m a = P \cdot m a = P ⋅ m Always equal to two: a = 2 ⋅ m a = 2 \cdot m a = 2 ⋅ m (independent of poles)
Voltage & Current Rating High-Current, Low-Voltage applications High-Voltage, Low-Current applications
Equalizer Rings Required to equalize unbalance currents caused by unequal pole fluxes Not required (conductors pass under all poles in series)
- Dummy Coils Not required Used occasionally to maintain mechanical rotor balance
- Fundamental Derivation of EMF & Torque Equations
- 1. RMS/Average Generated EMF Equation ( E g E_g E g )
Let:
- P P P = number of main magnetic poles
- Φ \Phi Φ = magnetic flux per pole in Webers (Wb)
- Z Z Z = total number of active armature conductors
- N N N = rotor speed in revolutions per minute (RPM)
- a a a = number of parallel paths ( a = P a = P a = P for lap, a = 2 a = 2 a = 2 for wave)
In one complete revolution ( 60 / N 60 / N 60/ N seconds), a single armature conductor cuts a total magnetic flux of P Φ P \Phi P Φ Webers. By Faraday's law, average EMF induced per conductor is: ≠ avg = d Φ d t = P Φ 60 N = P Φ N 60 Volts \ne_{\text{avg}} = \frac{d\Phi}{dt} = \frac{P \Phi}{\frac{60}{N}} = \frac{P \Phi N}{60} \quad \text{Volts} = avg = d t d Φ = N 60 P Φ = 60 P Φ N Volts
Since Z Z Z total conductors are divided into a a a parallel paths, the number of conductors connected in series per path is Z a \frac{Z}{a} a Z . The total Armature Generated EMF ( E g E_g E g ) is: E g = P Φ Z N 60 a E_g = \frac{P \Phi Z N}{60 a} E g = 60 a P Φ ZN
2. Electromagnetic Torque Equation ( T e T_e T e )
Total mechanical power developed in the armature equals total converted electrical power: P mech = T e ω m = T e ( 2 π N 60 ) = E g I a P_{\text{mech}} = T_e \omega_m = T_e \left( \frac{2 \pi N}{60} \right) = E_g I_a P mech = T e ω m = T e ( 60 2 π N ) = E g I a
Substituting E g = P Φ Z N 60 a E_g = \frac{P \Phi Z N}{60 a} E g = 60 a P Φ ZN into the power equality: T e ( 2 π N 60 ) = ( P Φ Z N 60 a ) I a T_e \left( \frac{2 \pi N}{60} \right) = \left( \frac{P \Phi Z N}{60 a} \right) I_a T e ( 60 2 π N ) = ( 60 a P Φ ZN ) I a
Solving for Electromagnetic Developed Torque ( T e T_e T e ) : T e = P Φ Z I a 2 π a = ( 1 2 π ) ( P Z a ) Φ I a = 0.159 ( P Z a ) Φ I a ( N ⋅ m ) T_e = \frac{P \Phi Z I_a}{2 \pi a} = \left( \frac{1}{2\pi} \right) \left( \frac{P Z}{a} \right) \Phi I_a = 0.159 \left( \frac{P Z}{a} \right) \Phi I_a \quad (\text{N}\cdot\text{m}) T e = 2 πa P Φ Z I a = ( 2 π 1 ) ( a PZ ) Φ I a = 0.159 ( a PZ ) Φ I a ( N ⋅ m )
- DC Generator Classification & Voltage Buildup Requirements
- DC generators are classified by their field excitation methods: DC GENERATOR SCHEMATIC CLASSIFICATIONS
- SEPARATELY EXCITED SHUNT GENERATOR SERIES GENERATOR
- ┌───────────┐ ┌──────┬──────┐ ┌───█████───┬───┐
- Ext.DC █ Field Coil│ │ │ │ │ Series │ │
- Source └───────────┘ ┌─┴─┐ ███ │ ┌─┴─┐ Field │ ███ Load
- ┌───────────┐ │ G │ ███ Rf ███ Load │ G │ ███
- │ Armature ├─► V_t └─┬─┘ │ ███ └─┬─┘ │
- └───────────┘ └──────┴──────┘ └───────────┴───┘
- Governing Terminal Equations
Shunt Generator : Field winding connected in parallel across armature ( I a = I L + I f I_a = I_L + I_f I a = I L + I f , I f = V t R f I_f = \frac{V_t}{R_f} I f = R f V t ). V t = E g − I a R a V_t = E_g - I_a R_a V t = E g − I a R a
Series Generator : Field winding connected in series with armature ( I a = I s = I L I_a = I_s = I_L I a = I s = I L ). V t = E g − I a ( R a + R s ) V_t = E_g - I_a(R_a + R_s) V t = E g − I a ( R a + R s )
Compound Generator : Contains both shunt and series field windings.
Cumulative Compounding : Series field flux aids shunt field flux ( Φ total = Φ f + Φ s \Phi_{\text{total}} = \Phi_f + \Phi_s Φ total = Φ f + Φ s ). Can be over-compounded, flat-compounded, or under-compounded to compensate for line drop.
Differential Compounding : Series field flux opposes shunt field flux ( Φ total = Φ f − Φ s \Phi_{\text{total}} = \Phi_f - \Phi_s Φ total = Φ f − Φ s ). Used in specialized arc welding generators.
Long-Shunt vs. Short-Shunt : In long-shunt, shunt field is connected across both armature and series field ( I f = V t / R f I_f = V_t / R_f I f = V t / R f ). In short-shunt, shunt field is connected across armature directly ( I f = ( V t + I a R s ) / R f I_f = (V_t + I_a R_s)/R_f I f = ( V t + I a R s ) / R f ).
Conditions for Self-Excited Voltage Buildup in Shunt Generators
To successfully build up terminal voltage from zero, a self-excited DC shunt generator must fulfill three statutory conditions:
Presence of Residual Magnetism : The iron pole cores must retain a small residual magnetic flux (yielding residual voltage E res ≈ 2 % − 5 % E_{\text{res}} \approx 2\% - 5\% E res ≈ 2% − 5% of rated V t V_t V t ).
Field Resistance Below Critical Resistance ( R f < R c R_f < R_c R f < R c ) : The resistance of the shunt field circuit must be less than the critical field resistance slope ( R c R_c R c ) tangent to the No-Load Magnetization Curve (OCC) at operating speed.
Proper Field Polarity & Rotation Direction : Field coils must be connected such that initial current driven by E res E_{\text{res}} E res produces flux that aids residual flux. If connected backward, residual flux is destroyed and voltage drops to zero.
DC Motor Back-EMF & Speed Governing
When DC supply voltage V t V_t V t is applied to a DC motor, armature conductors rotate through the main magnetic field, inducing a counter-EMF known as Back-EMF ( E b E_b E b ) by Faraday's law: E b = P Φ Z N 60 a E_b = \frac{P \Phi Z N}{60 a} E b = 60 a P Φ ZN
By Lenz's law, back-EMF opposes applied terminal voltage. Armature current is governed by: I a = V t − E b R a I_a = \frac{V_t - E_b}{R_a} I a = R a V t − E b
Mechanical Power Output Optimization
Multiplying by I a I_a I a gives the electrical power balance: V t I a = E b I a + I a 2 R a ⟹ P in = P mech + P cu,armature V_t I_a = E_b I_a + I_a^2 R_a \implies P_{\text{in}} = P_{\text{mech}} + P_{\text{cu,armature}} V t I a = E b I a + I a 2 R a ⟹ P in = P mech + P cu,armature
Maximum mechanical power developed occurs when d P mech d I a = 0 \frac{d P_{\text{mech}}}{d I_a} = 0 d I a d P mech = 0 , yielding: E b = V t 2 E_b = \frac{V_t}{2} E b = 2 V t
(At maximum mechanical power output, motor efficiency is 50%).
General DC Motor Speed Formula
Substituting E b = k Φ N E_b = k \Phi N E b = k Φ N into the voltage equation yields the fundamental Speed Equation : N = 60 a E b P Φ Z = k ( V t − I a R a Φ ) N = \frac{60 a E_b}{P \Phi Z} = k \left( \frac{V_t - I_a R_a}{\Phi} \right) N = P Φ Z 60 a E b = k ( Φ V t − I a R a )
Speed Control Methods & Motor Starters
From N ∝ V t − I a R a Φ N \propto \frac{V_t - I_a R_a}{\Phi} N ∝ Φ V t − I a R a , motor speed is controlled via three methods: DC MOTOR SPEED CONTROL REGIONS & OPERATING LIMITS
- Speed N ▲
- │ Below Base Speed │ Above Base Speed
- │ (Armature Voltage Control) │ (Field Flux Control)
- │ Constant Torque Region │ Constant Power Region
- Base Speed├────────────────────────────────┼─────────────────────────►
- │ Power P ∝ N │ Power P = Constant
- │ Torque T = Constant │ Torque T ∝ 1/N
- └────────────────────────────────┴─────────────────────────►
- Armature Voltage Vt
- 1. Field Flux Control (Shunt Field Rheostat)
Inserting resistance in series with the shunt field reduces flux Φ \Phi Φ .
Since N ∝ 1 / Φ N \propto 1 / \Phi N ∝ 1/Φ , speed increases above rated base speed .
Provides constant kW, variable torque operation.
2. Armature Voltage Control (Ward-Leonard System / Variable DC Supply)
Varying applied armature voltage V t V_t V t while maintaining constant field flux Φ \Phi Φ .
Speed varies linearly from zero up to rated base speed ( N ∝ V t N \propto V_t N ∝ V t ).
Provides smooth speed control, constant torque operation, and regenerative braking.
3. Armature Resistance Control
Inserting external resistance R ext R_{\text{ext}} R ext in series with armature circuit.
Reduces speed below base speed, but exhibits poor speed regulation and severe I 2 R I^2 R I 2 R power loss.
Motor Starters (3-Point and 4-Point Starters)
At standstill ( N = 0 N = 0 N = 0 ), back-EMF is zero ( E b = 0 E_b = 0 E b = 0 ). If connected directly to line voltage, starting current would be dangerously high: I start = V t − 0 R a ≈ 10 − 20 × I full-load I_{\text{start}} = \frac{V_t - 0}{R_a} \approx 10 - 20 \times I_{\text{full-load}} I start = R a V t − 0 ≈ 10 − 20 × I full-load
To limit starting current, external resistance is inserted by a starter and cut out in steps as speed rises:
3-Point Starter : Contains No-Volt Release (NVR) coil connected in series with the shunt field. Disadvantage: high field resistance added for high-speed control weakens NVR magnet, causing handle trip.
4-Point Starter : Connects NVR coil in series with a protective resistor across full line voltage independently of shunt field, permitting wide field speed control.
DC Series Motor Performance & SAFETY MANDATE
In a DC series motor, field coils are in series with armature ( I a = I s I_a = I_s I a = I s , Φ ∝ I a \Phi \propto I_a Φ ∝ I a below saturation). T e ∝ Φ I a ∝ I a 2 T_e \propto \Phi I_a \propto I_a^2 T e ∝ Φ I a ∝ I a 2
DC series motors produce extremely high starting torque ( T ∝ I a 2 T \propto I_a^2 T ∝ I a 2 ), making them ideal for heavy electric traction, trains, hoists, cranes, and elevators.
CRITICAL REE EXAM SAFETY MANDATE: NO-LOAD RUNAWAY HAZARD
Mandatory Safety Rule: A DC series motor must NEVER be started or operated without a mechanical load (never use belt drives; use direct gearing).
Physical Mechanism: At no-load, armature current drops to a tiny magnetizing value ( I a → 0 I_a \to 0 I a → 0 ). Because series field flux is driven by armature current, flux collapses toward zero ( Φ → 0 \Phi \to 0 Φ → 0 ).
Consequence: From N ∝ E b Φ N \propto \frac{E_b}{\Phi} N ∝ Φ E b , as flux Φ → 0 \Phi \to 0 Φ → 0 , motor speed accelerates toward infinity ( N → ∞ N \to \infty N → ∞ ). The resulting extreme centrifugal force causes catastrophic mechanical destruction, hurling armature windings and commutator segments outward.