Study guide
3.3 Second Law, Entropy, Exergy & Reversibility Analysis
PRC Mechanical Engineer Licensure Examination MELE
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Licensing Overview, Law & Professional Ethics
1.1 MELE Facts, RA 8495 & Board Organization 1.2 Code of Ethics for Mechanical Engineers & Professional Practice 1.3 Philippine Mechanical Engineering Code (PME Code) Governance & Legal Mandates
2 Chapter 2: Advanced Mathematics & Engineering Statistics
2.1 Differential & Integral Calculus in Engineering Applications 2.2 Differential Equations & Mathematical Modeling 2.3 Applied Engineering Statistics & Quality Control Probability
3 Chapter 3: Engineering Thermodynamics
3.1 Thermodynamic State Postulate, Properties & P-V-T Equations of State 3.2 First Law Analysis for Open & Closed Thermal Systems 3.3 Second Law, Entropy, Exergy & Reversibility Analysis
4 Chapter 4: Fluid Mechanics & Hydraulic Engineering
4.1 Fluid Statics, Manometry, Hydrostatic Force & Buoyancy 4.2 Fluid Kinematics, Dynamics & Bernoulli Equation 4.3 Pipe Flow, Friction Losses & Piping Network Analysis
5 Chapter 5: Heat Transfer & Thermal Systems
5.1 Conduction Heat Transfer & Thermal Insulation Design 5.2 Natural & Forced Convection Heat Transfer Correlations 5.3 Thermal Radiation & Industrial Heat Exchanger Design
6 Chapter 6: Mechanics & Strength of Materials
6.1 Statics & Dynamics of Rigid Bodies & Engineering Linkages 6.2 Normal, Shear & Triaxial Stress-Strain Relationships 6.3 Bending Stresses, Torsion & Column Buckling Analysis
7 Chapter 7: Engineering Economics & Financial Analysis
7.1 Time Value of Money & Cash Flow Equivalence Formulas 7.2 Asset Depreciation, Taxation & Economic Evaluation Methods 7.3 Break-Even Analysis, Payback Period & EOQ Inventory Models
8 Chapter 8: Engineering Materials & Metallurgy
8.1 Ferrous & Non-Ferrous Metals, Alloys & Polymers 8.2 Phase Diagrams, Iron-Carbon System & Heat Treatment 8.3 Mechanical Testing, Fatigue Failure & Fracture Mechanics
9 Chapter 9: Machine Elements & Stress Analysis
9.1 Failure Theories, Static & Fluctuating Stress Design 9.2 Power Transmission Shafts, Keys & Rigid/Flexible Couplings 9.3 Spur, Helical, Bevel & Worm Gear Design Calculations
10 Chapter 10: Power Transmission Components
10.1 Belts, V-Belts, Chains, Wire Ropes & Flywheels 10.2 Rolling Element & Hydrodynamic Journal Bearings 10.3 Mechanical Springs, Clutches & Industrial Brakes
11 Chapter 11: Manufacturing, Fasteners & GD&T
11.1 Threaded Fasteners, Rivets & Welded Joint Analysis 11.2 Manufacturing Processes, Machine Tools & Machining Calculations 11.3 Engineering Drawing, Limits, Fits, Tolerances & GD&T
12 Chapter 12: Power Plants, Boilers & Thermal Power Cycles
12.1 Steam Power Plants & Rankine Cycles 12.2 Steam Generators, Boilers & Combustion Engineering 12.3 Internal Combustion Engines: SI & CI Cycles 12.4 Gas Turbine Power Plants & Combined Cycles
13 Chapter 13: Renewable Energy, Fluid Machinery & Plant Systems
13.1 Hydroelectric, Geothermal & Renewable Energy Power Plants 13.2 Pumps & Hydraulic Machinery 13.3 Air Compressors, Fans & Blowers
14 Chapter 14: Refrigeration, HVAC & Building Mechanical Systems
14.1 Refrigeration Systems, Cycles & Refrigerants 14.2 Psychrometrics & Air Conditioning Systems 14.3 Piping/Ductwork Design, PME Code & Industrial Safety Management
3.3 Second Law, Entropy, Exergy & Reversibility Analysis
Key Takeaways Explain This Topic AI
The Second Law of Thermodynamics dictates process directionality via Kelvin-Planck and Clausius statements, setting upper efficiency limits for heat engines and thermal pumps.
Carnot principles establish that maximum theoretical efficiency depends solely on absolute source and sink temperatures: η_Carnot = 1 - T_L / T_H.
Entropy is a state property defined by dS = (dQ/T)_rev; entropy generation S_gen >= 0 measures process irreversibility and degradation of energy quality.
Isentropic efficiencies quantify performance losses in real adiabatic turbines (η_t = w_a / w_s) and compressors (η_c = w_s / w_a) relative to ideal reversible processes.
Exergy (availability) represents maximum useful work potential relative to a dead state (P0, T0); exergy destruction is directly proportional to entropy generation (X_destroyed = I = T0 S_gen).
Last updated: July 2026
3.3 Second Law, Entropy, Exergy & Reversibility Analysis
While the First Law of Thermodynamics establishes energy conservation, it places no constraint on the direction of energy transfers. Real physical processes occur spontaneously in one direction only. The Second Law of Thermodynamics identifies process directionality, asserts that energy has quality as well as quantity, and establishes theoretical performance limits for thermal power plants, heat pumps, and refrigeration systems.
1. Classical Statements of the Second Law
Kelvin-Planck Statement It is impossible for any device that operates on a thermodynamic cycle to receive heat from a single thermal reservoir \text{It is impossible for any device that operates on a thermodynamic cycle to receive heat from a single thermal reservoir} It is impossible for any device that operates on a thermodynamic cycle to receive heat from a single thermal reservoir and produce a net amount of work. \text{and produce a net amount of work.} and produce a net amount of work.
This statement dictates that no heat engine can convert 100% of absorbed heat into useful work. Heat must be rejected to a low-temperature sink ( Q L > 0 Q_L > 0 Q L > 0 ). η th = W net,out Q H = Q H − Q L Q H = 1 − Q L Q H < 100 % \eta_{\text{th}} = \frac{W_{\text{net,out}}}{Q_H} = \frac{Q_H - Q_L}{Q_H} = 1 - \frac{Q_L}{Q_H} < 100\% η th = Q H W net,out = Q H Q H − Q L = 1 − Q H Q L < 100%
Clausius Statement It is impossible to construct a device that operates in a cycle and produces no effect other than standard work input \text{It is impossible to construct a device that operates in a cycle and produces no effect other than standard work input} It is impossible to construct a device that operates in a cycle and produces no effect other than standard work input to transfer heat from a lower-temperature body to a higher-temperature body. \text{to transfer heat from a lower-temperature body to a higher-temperature body.} to transfer heat from a lower-temperature body to a higher-temperature body.
This asserts that heat cannot flow spontaneously from a cold medium to a warm medium without external work input ( W in > 0 W_{\text{in}} > 0 W in > 0 ).
Coefficient of Performance (COP)
Refrigerators and heat pumps operate on cyclic refrigeration cycles: COP R = Desired Output Required Work = Q L W in = Q L Q H − Q L \text{COP}_{R} = \frac{\text{Desired Output}}{\text{Required Work}} = \frac{Q_L}{W_{\text{in}}} = \frac{Q_L}{Q_H - Q_L} COP R = Required Work Desired Output = W in Q L = Q H − Q L Q L COP H P = Desired Output Required Work = Q H W in = Q H Q H − Q L = COP R + 1 \text{COP}_{HP} = \frac{\text{Desired Output}}{\text{Required Work}} = \frac{Q_H}{W_{\text{in}}} = \frac{Q_H}{Q_H - Q_L} = \text{COP}_{R} + 1 COP H P = Required Work Desired Output = W in Q H = Q H − Q L Q H = COP R + 1
2. The Carnot Cycle & Absolute Temperature Scale
The Carnot Cycle is a theoretical, totally reversible cycle composed of four reversible processes:
- Reversible Isothermal Heat Addition ( T H = constant T_H = \text{constant} T H = constant )
- Reversible Adiabatic (Isentropic) Expansion
- Reversible Isothermal Heat Rejection ( T L = constant T_L = \text{constant} T L = constant )
- Reversible Adiabatic (Isentropic) Compression
- Carnot Principles
The efficiency of an irreversible heat engine is always less than the efficiency of a reversible engine operating between the same two reservoirs.
The efficiencies of all reversible heat engines operating between the same two reservoirs are identical.
Carnot Thermal Efficiency & COPs
For any reversible (Carnot) cycle, heat ratio equals absolute temperature ratio ( Q L / Q H = T L / T H Q_L/Q_H = T_L/T_H Q L / Q H = T L / T H in Kelvin): η th,Carnot = 1 − T L T H \eta_{\text{th,Carnot}} = 1 - \frac{T_L}{T_H} η th,Carnot = 1 − T H T L COP R , Carnot = T L T H − T L , COP H P , Carnot = T H T H − T L \text{COP}_{R,\text{Carnot}} = \frac{T_L}{T_H - T_L}, \quad \text{COP}_{HP,\text{Carnot}} = \frac{T_H}{T_H - T_L} COP R , Carnot = T H − T L T L , COP H P , Carnot = T H − T L T H
Crucial Rule : All temperatures in Carnot formulas MUST be expressed in absolute scale (Kelvin: K = ∘ C + 273.15 \text{K} = ^\circ\text{C} + 273.15 K = ∘ C + 273.15 ).
- 3. Clausius Inequality & Definition of Entropy
- The Clausius Inequality
- For any cyclic process: ∮ δ Q T ≤ 0 \oint \frac{\delta Q}{T} \le 0 ∮ T δ Q ≤ 0
- ∮ δ Q T = 0 \oint \frac{\delta Q}{T} = 0 ∮ T δ Q = 0 (Totally reversible cycle)
- ∮ δ Q T < 0 \oint \frac{\delta Q}{T} < 0 ∮ T δ Q < 0 (Irreversible cycle)
- ∮ δ Q T > 0 \oint \frac{\delta Q}{T} > 0 ∮ T δ Q > 0 (Impossible cycle)
- Definition of Entropy ( S S S )
Entropy is an extensive thermodynamic property defined by the differential relation: d S = ( δ Q T ) rev ⟹ Δ S = S 2 − S 1 = ∫ 1 2 ( δ Q T ) rev dS = \left( \frac{\delta Q}{T} \right)_{\text{rev}} \implies \Delta S = S_2 - S_1 = \int_1^2 \left( \frac{\delta Q}{T} \right)_{\text{rev}} d S = ( T δ Q ) rev ⟹ Δ S = S 2 − S 1 = ∫ 1 2 ( T δ Q ) rev
The Increase of Entropy Principle
For any real, irreversible process in an isolated or combined system: S gen ≥ 0 ⟹ Δ S total = Δ S system + Δ S surroundings = S gen S_{\text{gen}} \ge 0 \implies \Delta S_{\text{total}} = \Delta S_{\text{system}} + \Delta S_{\text{surroundings}} = S_{\text{gen}} S gen ≥ 0 ⟹ Δ S total = Δ S system + Δ S surroundings = S gen
- S gen = 0 S_{\text{gen}} = 0 S gen = 0 : Reversible process
- S gen > 0 S_{\text{gen}} > 0 S gen > 0 : Irreversible process
- S gen < 0 S_{\text{gen}} < 0 S gen < 0 : Impossible process
Entropy Changes for Ideal Gases (Constant Specific Heats) Δ s = s 2 − s 1 = c v ln ( T 2 T 1 ) + R ln ( v 2 v 1 ) \Delta s = s_2 - s_1 = c_v \ln\left(\frac{T_2}{T_1}\right) + R \ln\left(\frac{v_2}{v_1}\right) Δ s = s 2 − s 1 = c v ln ( T 1 T 2 ) + R ln ( v 1 v 2 ) Δ s = s 2 − s 1 = c p ln ( T 2 T 1 ) − R ln ( P 2 P 1 ) \Delta s = s_2 - s_1 = c_p \ln\left(\frac{T_2}{T_1}\right) - R \ln\left(\frac{P_2}{P_1}\right) Δ s = s 2 − s 1 = c p ln ( T 1 T 2 ) − R ln ( P 1 P 2 )
Isentropic ( s 2 = s 1 s_2 = s_1 s 2 = s 1 ) Relations for Ideal Gases ( n = k = c p / c v n = k = c_p/c_v n = k = c p / c v ) T 2 T 1 = ( P 2 P 1 ) k − 1 k = ( v 1 v 2 ) k − 1 \frac{T_2}{T_1} = \left( \frac{P_2}{P_1} \right)^{\frac{k-1}{k}} = \left( \frac{v_1}{v_2} \right)^{k-1} T 1 T 2 = ( P 1 P 2 ) k k − 1 = ( v 2 v 1 ) k − 1
4. Isentropic Efficiencies of Thermal Turbomachinery
Real adiabatic devices (turbines, compressors, pumps, nozzles) suffer from fluid friction, turbulence, and heat dissipation, causing entropy generation ( s 2 > s 1 s_2 > s_1 s 2 > s 1 ). Isentropic efficiency ( η \eta η ) compares actual performance against an ideal reversible adiabatic process.
1. Isentropic Efficiency of a Turbine ( η t \eta_t η t ) η t = Actual Turbine Work Isentropic Turbine Work = w a w s ≈ h 1 − h 2 a h 1 − h 2 s \eta_t = \frac{\text{Actual Turbine Work}}{\text{Isentropic Turbine Work}} = \frac{w_a}{w_s} \approx \frac{h_1 - h_{2a}}{h_1 - h_{2s}} η t = Isentropic Turbine Work Actual Turbine Work = w s w a ≈ h 1 − h 2 s h 1 − h 2 a
2. Isentropic Efficiency of a Compressor / Pump ( η c \eta_c η c ) η c = Isentropic Compressor Work Actual Compressor Work = w s w a ≈ h 2 s − h 1 h 2 a − h 1 \eta_c = \frac{\text{Isentropic Compressor Work}}{\text{Actual Compressor Work}} = \frac{w_s}{w_a} \approx \frac{h_{2s} - h_1}{h_{2a} - h_1} η c = Actual Compressor Work Isentropic Compressor Work = w a w s ≈ h 2 a − h 1 h 2 s − h 1
3. Isentropic Efficiency of a Nozzle ( η n \eta_n η n ) η n = Actual Exit Kinetic Energy Isentropic Exit Kinetic Energy = V 2 a 2 V 2 s 2 ≈ h 1 − h 2 a h 1 − h 2 s \eta_n = \frac{\text{Actual Exit Kinetic Energy}}{\text{Isentropic Exit Kinetic Energy}} = \frac{\mathbf{V}_{2a}^2}{\mathbf{V}_{2s}^2} \approx \frac{h_1 - h_{2a}}{h_1 - h_{2s}} η n = Isentropic Exit Kinetic Energy Actual Exit Kinetic Energy = V 2 s 2 V 2 a 2 ≈ h 1 − h 2 s h 1 − h 2 a Turbine Expansion (T-s Diagram) Compressor Compression (T-s Diagram)
- T ^ T ^
- | 1 | 2a (Actual)
- | / \ | /|
- | / \ | / | 2s (Isentropic)
- |/ \ 2a (Actual) | / |
- |-------\ | 1---|------>
- | 2s (Isentropic) +------------------------> s
- +------------------------> s
- 5. Exergy (Availability) & Irreversibility Analysis
Exergy (or Availability) is the maximum useful work potential that can be extracted from a system or fluid stream as it comes into complete thermodynamic equilibrium with its environment at the dead state ( P 0 = 101.325 kPa , T 0 = 298.15 K = 25 ∘ C P_0 = 101.325\text{ kPa}, T_0 = 298.15\text{ K} = 25^\circ\text{C} P 0 = 101.325 kPa , T 0 = 298.15 K = 2 5 ∘ C ).
Flow Exergy ( ψ \psi ψ ) per unit mass ψ = ( h − h 0 ) − T 0 ( s − s 0 ) + V 2 2 + g z \psi = (h - h_0) - T_0 (s - s_0) + \frac{\mathbf{V}^2}{2} + g z ψ = ( h − h 0 ) − T 0 ( s − s 0 ) + 2 V 2 + g z
Exergy Destruction & Gouy-Stodola Theorem
Energy cannot be destroyed, but exergy is destroyed whenever an irreversible process takes place. Exergy destruction ( X destroyed X_{\text{destroyed}} X destroyed ) or Irreversibility ( I I I ) is directly proportional to entropy generation: X destroyed = I = T 0 S gen X_{\text{destroyed}} = I = T_0 S_{\text{gen}} X destroyed = I = T 0 S gen X ˙ destroyed = I ˙ = T 0 S ˙ gen \dot{X}_{\text{destroyed}} = \dot{I} = T_0 \dot{S}_{\text{gen}} X ˙ destroyed = I ˙ = T 0 S ˙ gen
Second-Law Efficiency ( η II \eta_{\text{II}} η II ) η II = Thermal Efficiency Actual Thermal Efficiency Carnot = Exergy Recovered Exergy Supplied = 1 − X destroyed Exergy Supplied \eta_{\text{II}} = \frac{\text{Thermal Efficiency Actual}}{\text{Thermal Efficiency Carnot}} = \frac{\text{Exergy Recovered}}{\text{Exergy Supplied}} = 1 - \frac{X_{\text{destroyed}}}{\text{Exergy Supplied}} η II = Thermal Efficiency Carnot Thermal Efficiency Actual = Exergy Supplied Exergy Recovered = 1 − Exergy Supplied X destroyed
- 6. Step-by-Step Worked Numerical Calculation
- Problem Statement
A heat engine operating on a steady flow process receives thermal energy from a high-temperature heat source at T H = 1000.0 K T_H = 1000.0\text{ K} T H = 1000.0 K at a rate of Q ˙ H = 500.0 kW \dot{Q}_H = 500.0\text{ kW} Q ˙ H = 500.0 kW . The heat engine rejects waste heat to the ambient atmosphere at T 0 = T L = 300.0 K T_0 = T_L = 300.0\text{ K} T 0 = T L = 300.0 K . The measured actual net electric power output of the heat engine is W ˙ net,out = 275.0 kW \dot{W}_{\text{net,out}} = 275.0\text{ kW} W ˙ net,out = 275.0 kW .
Calculate :
The actual thermal efficiency ( η th \eta_{\text{th}} η th ) of the heat engine.
The maximum theoretical Carnot thermal efficiency ( η th,Carnot \eta_{\text{th,Carnot}} η th,Carnot ).
The rate of heat rejection ( Q ˙ L \dot{Q}_L Q ˙ L ) to the ambient air in kW.
The rate of entropy generation ( S ˙ gen \dot{S}_{\text{gen}} S ˙ gen ) in kW/K.
The rate of exergy destruction ( X ˙ destroyed \dot{X}_{\text{destroyed}} X ˙ destroyed or irreversibility I ˙ \dot{I} I ˙ ) in kW.
The Second-Law Efficiency ( η II \eta_{\text{II}} η II ) of the heat engine.
Step-by-Step Solution
Step 1: Calculate actual thermal efficiency ( η th \eta_{\text{th}} η th ) η th = W ˙ net,out Q ˙ H = 275.0 kW 500.0 kW = 0.5500 ( 55.00 % ) \eta_{\text{th}} = \frac{\dot{W}_{\text{net,out}}}{\dot{Q}_H} = \frac{275.0\text{ kW}}{500.0\text{ kW}} = 0.5500 \quad (55.00\%) η th = Q ˙ H W ˙ net,out = 500.0 kW 275.0 kW = 0.5500 ( 55.00% )
Step 2: Calculate Carnot maximum thermal efficiency ( η th,Carnot \eta_{\text{th,Carnot}} η th,Carnot ) η th,Carnot = 1 − T L T H = 1 − 300.0 K 1000.0 K = 1 − 0.3000 = 0.7000 ( 70.00 % ) \eta_{\text{th,Carnot}} = 1 - \frac{T_L}{T_H} = 1 - \frac{300.0\text{ K}}{1000.0\text{ K}} = 1 - 0.3000 = 0.7000 \quad (70.00\%) η th,Carnot = 1 − T H T L = 1 − 1000.0 K 300.0 K = 1 − 0.3000 = 0.7000 ( 70.00% )
Step 3: Calculate rate of heat rejection ( Q ˙ L \dot{Q}_L Q ˙ L ) From First-Law rate energy balance: Q ˙ H − Q ˙ L = W ˙ net,out ⟹ Q ˙ L = Q ˙ H − W ˙ net,out \dot{Q}_H - \dot{Q}_L = \dot{W}_{\text{net,out}} \implies \dot{Q}_L = \dot{Q}_H - \dot{W}_{\text{net,out}} Q ˙ H − Q ˙ L = W ˙ net,out ⟹ Q ˙ L = Q ˙ H − W ˙ net,out Q ˙ L = 500.0 kW − 275.0 kW = 225.0 kW \dot{Q}_L = 500.0\text{ kW} - 275.0\text{ kW} = 225.0\text{ kW} Q ˙ L = 500.0 kW − 275.0 kW = 225.0 kW
Step 4: Calculate rate of entropy generation ( S ˙ gen \dot{S}_{\text{gen}} S ˙ gen ) Apply entropy balance to the isolated combined system (heat engine + reservoirs): S ˙ gen = ∑ Q ˙ out T sink − ∑ Q ˙ in T source = Q ˙ L T L − Q ˙ H T H \dot{S}_{\text{gen}} = \sum \frac{\dot{Q}_{\text{out}}}{T}_{\text{sink}} - \sum \frac{\dot{Q}_{\text{in}}}{T}_{\text{source}} = \frac{\dot{Q}_L}{T_L} - \frac{\dot{Q}_H}{T_H} S ˙ gen = ∑ T Q ˙ out sink − ∑ T Q ˙ in source = T L Q ˙ L − T H Q ˙ H S ˙ gen = 225.0 kW 300.0 K − 500.0 kW 1000.0 K = 0.7500 − 0.5000 = 0.2500 kW/K \dot{S}_{\text{gen}} = \frac{225.0\text{ kW}}{300.0\text{ K}} - \frac{500.0\text{ kW}}{1000.0\text{ K}} = 0.7500 - 0.5000 = 0.2500\text{ kW/K} S ˙ gen = 300.0 K 225.0 kW − 1000.0 K 500.0 kW = 0.7500 − 0.5000 = 0.2500 kW/K
Step 5: Calculate rate of exergy destruction ( X ˙ destroyed \dot{X}_{\text{destroyed}} X ˙ destroyed ) Using the Gouy-Stodola theorem ( T 0 = 300.0 K T_0 = 300.0\text{ K} T 0 = 300.0 K ): X ˙ destroyed = T 0 S ˙ gen = 300.0 K × 0.2500 kW/K = 75.0 kW \dot{X}_{\text{destroyed}} = T_0 \dot{S}_{\text{gen}} = 300.0\text{ K} \times 0.2500\text{ kW/K} = 75.0\text{ kW} X ˙ destroyed = T 0 S ˙ gen = 300.0 K × 0.2500 kW/K = 75.0 kW
Alternative Check using Available Energy : Max Available Work W ˙ rev = η th,Carnot Q ˙ H = 0.7000 × 500.0 = 350.0 kW \text{Max Available Work } \dot{W}_{\text{rev}} = \eta_{\text{th,Carnot}} \dot{Q}_H = 0.7000 \times 500.0 = 350.0\text{ kW} Max Available Work W ˙ rev = η th,Carnot Q ˙ H = 0.7000 × 500.0 = 350.0 kW X ˙ destroyed = W ˙ rev − W ˙ actual = 350.0 kW − 275.0 kW = 75.0 kW \dot{X}_{\text{destroyed}} = \dot{W}_{\text{rev}} - \dot{W}_{\text{actual}} = 350.0\text{ kW} - 275.0\text{ kW} = 75.0\text{ kW} X ˙ destroyed = W ˙ rev − W ˙ actual = 350.0 kW − 275.0 kW = 75.0 kW
Step 6: Calculate Second-Law Efficiency ( η II \eta_{\text{II}} η II ) η II = η th η th,Carnot = 0.5500 0.7000 = 0.7857 ( 78.57 % ) \eta_{\text{II}} = \frac{\eta_{\text{th}}}{\eta_{\text{th,Carnot}}} = \frac{0.5500}{0.7000} = 0.7857 \quad (78.57\%) η II = η th,Carnot η th = 0.7000 0.5500 = 0.7857 ( 78.57% )
Final Summary of Results :
- Actual Thermal Efficiency η th = 55.00 % \eta_{\text{th}} = 55.00\% η th = 55.00%
- Carnot Maximum Efficiency η th,Carnot = 70.00 % \eta_{\text{th,Carnot}} = 70.00\% η th,Carnot = 70.00%
- Heat Rejection Rate Q ˙ L = 225.0 kW \dot{Q}_L = 225.0\text{ kW} Q ˙ L = 225.0 kW
Entropy Generation Rate S ˙ gen = 0.2500 kW/K \dot{S}_{\text{gen}} = 0.2500\text{ kW/K} S ˙ gen = 0.2500 kW/K
Exergy Destruction Rate X ˙ destroyed = 75.0 kW \dot{X}_{\text{destroyed}} = 75.0\text{ kW} X ˙ destroyed = 75.0 kW