Study guide

4.3 Pipe Flow, Friction Losses & Piping Network Analysis

PRC Mechanical Engineer Licensure Examination MELE

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Licensing Overview, Law & Professional Ethics

1.1 MELE Facts, RA 8495 & Board Organization 1.2 Code of Ethics for Mechanical Engineers & Professional Practice 1.3 Philippine Mechanical Engineering Code (PME Code) Governance & Legal Mandates

2 Chapter 2: Advanced Mathematics & Engineering Statistics

2.1 Differential & Integral Calculus in Engineering Applications 2.2 Differential Equations & Mathematical Modeling 2.3 Applied Engineering Statistics & Quality Control Probability

3 Chapter 3: Engineering Thermodynamics

3.1 Thermodynamic State Postulate, Properties & P-V-T Equations of State 3.2 First Law Analysis for Open & Closed Thermal Systems 3.3 Second Law, Entropy, Exergy & Reversibility Analysis

4 Chapter 4: Fluid Mechanics & Hydraulic Engineering

4.1 Fluid Statics, Manometry, Hydrostatic Force & Buoyancy 4.2 Fluid Kinematics, Dynamics & Bernoulli Equation 4.3 Pipe Flow, Friction Losses & Piping Network Analysis

5 Chapter 5: Heat Transfer & Thermal Systems

5.1 Conduction Heat Transfer & Thermal Insulation Design 5.2 Natural & Forced Convection Heat Transfer Correlations 5.3 Thermal Radiation & Industrial Heat Exchanger Design

6 Chapter 6: Mechanics & Strength of Materials

6.1 Statics & Dynamics of Rigid Bodies & Engineering Linkages 6.2 Normal, Shear & Triaxial Stress-Strain Relationships 6.3 Bending Stresses, Torsion & Column Buckling Analysis

7 Chapter 7: Engineering Economics & Financial Analysis

7.1 Time Value of Money & Cash Flow Equivalence Formulas 7.2 Asset Depreciation, Taxation & Economic Evaluation Methods 7.3 Break-Even Analysis, Payback Period & EOQ Inventory Models

8 Chapter 8: Engineering Materials & Metallurgy

8.1 Ferrous & Non-Ferrous Metals, Alloys & Polymers 8.2 Phase Diagrams, Iron-Carbon System & Heat Treatment 8.3 Mechanical Testing, Fatigue Failure & Fracture Mechanics

9 Chapter 9: Machine Elements & Stress Analysis

9.1 Failure Theories, Static & Fluctuating Stress Design 9.2 Power Transmission Shafts, Keys & Rigid/Flexible Couplings 9.3 Spur, Helical, Bevel & Worm Gear Design Calculations

10 Chapter 10: Power Transmission Components

10.1 Belts, V-Belts, Chains, Wire Ropes & Flywheels 10.2 Rolling Element & Hydrodynamic Journal Bearings 10.3 Mechanical Springs, Clutches & Industrial Brakes

11 Chapter 11: Manufacturing, Fasteners & GD&T

11.1 Threaded Fasteners, Rivets & Welded Joint Analysis 11.2 Manufacturing Processes, Machine Tools & Machining Calculations 11.3 Engineering Drawing, Limits, Fits, Tolerances & GD&T

12 Chapter 12: Power Plants, Boilers & Thermal Power Cycles

12.1 Steam Power Plants & Rankine Cycles 12.2 Steam Generators, Boilers & Combustion Engineering 12.3 Internal Combustion Engines: SI & CI Cycles 12.4 Gas Turbine Power Plants & Combined Cycles

13 Chapter 13: Renewable Energy, Fluid Machinery & Plant Systems

13.1 Hydroelectric, Geothermal & Renewable Energy Power Plants 13.2 Pumps & Hydraulic Machinery 13.3 Air Compressors, Fans & Blowers

14 Chapter 14: Refrigeration, HVAC & Building Mechanical Systems

14.1 Refrigeration Systems, Cycles & Refrigerants 14.2 Psychrometrics & Air Conditioning Systems 14.3 Piping/Ductwork Design, PME Code & Industrial Safety Management

4.3 Pipe Flow, Friction Losses & Piping Network Analysis

Key Takeaways Explain This Topic AI

Internal pipe flows are categorized by Reynolds number ( R e = ρ V D / μ Re = \rho V D / \mu R e = ρ V D / μ ): Laminar ( R e < 2300 Re < 2300 R e < 2300 ), Critical Transition ( 2300 ≤ R e ≤ 4000 2300 \le Re \le 4000 2300 ≤ R e ≤ 4000 ), and Turbulent ( R e > 4000 Re > 4000 R e > 4000 ).

Major friction head loss is calculated using the Darcy-Weisbach equation h f = f ( L / D ) ( V 2 / 2 g ) h_f = f (L/D) (V^2/2g) h f ​ = f ( L / D ) ( V 2 /2 g ) , where f = 64 / R e f = 64/Re f = 64/ R e for laminar flow and f ( ε / D , R e ) f(\varepsilon/D, Re) f ( ε / D , R e ) is determined via Colebrook-White or Swamee-Jain formulas for turbulent flow.

Minor head losses from fittings, valves, expansions, and bends are quantified as h m = K ( V 2 / 2 g ) h_m = K (V^2/2g) h m ​ = K ( V 2 /2 g ) or converted using equivalent pipe lengths L e q = K D / f L_{eq} = K D / f L e q ​ = KD / f .

Piping networks require parallel flow head loss equality ( h L 1 = h L 2 h_{L1} = h_{L2} h L 1 ​ = h L 2 ​ ) and series flow discharge continuity ( Q 1 = Q 2 Q_1 = Q_2 Q 1 ​ = Q 2 ​ ), analyzed iteratively for loops using the Hardy Cross method.

Water hammer pressure surges resulting from sudden valve closures propagate at acoustic wave speed c c c and generate peak pressure rises defined by Joukowsky's equation Δ P = ρ c Δ V \Delta P = \rho c \Delta V Δ P = ρ c Δ V .

Last updated: July 2026

4.3 Pipe Flow, Friction Losses & Piping Network Analysis

Fluid transport through enclosed conduits and piping networks is vital across industrial process plants, municipal water distribution networks, hydraulic power systems, and HVAC installations. Accurate determination of major frictional head loss, minor fitting losses, flow distribution in complex loops, and transient water hammer surges is fundamental to mechanical engineering design.

1. Flow Regimes & Reynolds Number

Flow character in round pipes is governed by the non-dimensional Reynolds Number ( R e Re R e ) , representing the ratio of inertial forces to viscous forces: R e = ρ V D μ = V D ν = 4 Q π D ν Re = \frac{\rho V D}{\mu} = \frac{V D}{\nu} = \frac{4 Q}{\pi D \nu} R e = μ ρ V D ​ = ν V D ​ = π D ν 4 Q ​

where V V V is average velocity, D D D is internal diameter, ρ \rho ρ is density, μ \mu μ is dynamic viscosity, and ν = μ / ρ \nu = \mu/\rho ν = μ / ρ is kinematic viscosity.

Flow Regime Classifications for Circular Pipes:

Laminar Flow ( R e < 2300 Re < 2300 R e < 2300 ): Fluid moves in smooth parallel layers (laminae) without microscopic mixing. Velocity profile is parabolic with peak velocity at centerline equal to twice average velocity ( V m a x = 2 V a v g V_{max} = 2 V_{avg} V ma x ​ = 2 V a vg ​ ).

Transitional Flow ( 2300 ≤ R e ≤ 4000 2300 \le Re \le 4000 2300 ≤ R e ≤ 4000 ): Flow fluctuates unpredictably between laminar and turbulent states.

Turbulent Flow ( R e > 4000 Re > 4000 R e > 4000 ): Chaotic, highly mixed fluid motion dominated by turbulent eddies. Velocity profile becomes flattened ( V m a x ≈ 1.15 − 1.25 V a v g V_{max} \approx 1.15 - 1.25 V_{avg} V ma x ​ ≈ 1.15 − 1.25 V a vg ​ ).

2. Major Friction Loss: Darcy-Weisbach Equation

The fundamental equation for head loss due to pipe wall friction is the Darcy-Weisbach Equation : h f = f L D V 2 2 g = 8 f L Q 2 π 2 g D 5 h_f = f \frac{L}{D} \frac{V^2}{2g} = \frac{8 f L Q^2}{\pi^2 g D^5} h f ​ = f D L ​ 2 g V 2 ​ = π 2 g D 5 8 f L Q 2 ​

where f f f is the dimensionless Darcy Friction Factor , L L L is pipe length, and D D D is internal diameter.

Determination of Friction Factor ( f f f ):

Laminar Flow ( R e < 2300 Re < 2300 R e < 2300 ): Derived analytically from the Hagen-Poiseuille law, independent of pipe surface roughness: f = 64 R e f = \frac{64}{Re} f = R e 64 ​

Turbulent Flow ( R e > 4000 Re > 4000 R e > 4000 ): Friction factor depends on both R e Re R e and Relative Roughness ( ε / D \varepsilon / D ε / D ) , where ε \varepsilon ε is absolute surface roughness height.

  • Pipe Material Absolute Roughness ε \varepsilon ε [mm] Absolute Roughness ε \varepsilon ε [ft]
  • Drawn Copper / Plastic (Smooth) 0.0015 0.0015 0.0015 0.000005 0.000005 0.000005
  • Commercial Steel / Wrought Iron 0.045 0.045 0.045 0.00015 0.00015 0.00015
  • Galvanized Iron 0.15 0.15 0.15 0.0005 0.0005 0.0005
  • Cast Iron 0.26 0.26 0.26 0.00085 0.00085 0.00085
  • Rivet Steel / Concrete 0.9 − 3.0 0.9 - 3.0 0.9 − 3.0 0.003 − 0.010 0.003 - 0.010 0.003 − 0.010

Turbulent Friction Factor Formulas:

Colebrook-White Equation (Implicit Standard): 1 f = − 2.0 log ⁡ 10 ( ε / D 3.7 + 2.51 R e f ) \frac{1}{\sqrt{f}} = -2.0 \log_{10} \left( \frac{\varepsilon / D}{3.7} + \frac{2.51}{Re \sqrt{f}} \right) f ​ 1 ​ = − 2.0 lo g 10 ​ ( 3.7 ε / D ​ + R e f ​ 2.51 ​ )

Swamee-Jain Equation (Explicit Approximation): Direct calculation within 1 % 1\% 1% accuracy for 10 − 6 ≤ ε / D ≤ 10 − 2 10^{-6} \le \varepsilon/D \le 10^{-2} 1 0 − 6 ≤ ε / D ≤ 1 0 − 2 and 5000 ≤ R e ≤ 10 8 5000 \le Re \le 10^8 5000 ≤ R e ≤ 1 0 8 : f = 0.25 [ log ⁡ 10 ( ε / D 3.7 + 5.74 R e 0.9 ) ] 2 f = \frac{0.25}{\left[ \log_{10} \left( \frac{\varepsilon / D}{3.7} + \frac{5.74}{Re^{0.9}} \right) \right]^2} f = [ lo g 10 ​ ( 3.7 ε / D ​ + R e 0.9 5.74 ​ ) ] 2 0.25 ​

Wholly Rough Turbulent Flow ( R e → ∞ Re \to \infty R e → ∞ ): Friction factor becomes independent of R e Re R e : 1 f = − 2.0 log ⁡ 10 ( ε / D 3.7 ) \frac{1}{\sqrt{f}} = -2.0 \log_{10} \left( \frac{\varepsilon / D}{3.7} \right) f ​ 1 ​ = − 2.0 lo g 10 ​ ( 3.7 ε / D ​ )

3. Minor Head Losses in Piping Components

Losses due to geometry changes (valves, fittings, elbows, expansions, contractions, entrances, exits) are termed minor losses : h m = K V 2 2 g h_m = K \frac{V^2}{2g} h m ​ = K 2 g V 2 ​

where K K K is the dimensionless loss coefficient.

Alternatively, minor losses are expressed as an Equivalent Pipe Length ( L e q L_{eq} L e q ​ ) : L e q = K ⋅ D f ⟹ h L , t o t a l = f D ( L + ∑ L e q ) V 2 2 g L_{eq} = \frac{K \cdot D}{f} \implies h_{L,total} = \frac{f}{D} \left( L + \sum L_{eq} \right) \frac{V^2}{2g} L e q ​ = f K ⋅ D ​ ⟹ h L , t o t a l ​ = D f ​ ( L + ∑ L e q ​ ) 2 g V 2 ​

  • Piping Component Loss Coefficient K K K Equivalent Length Ratio ( L e q / D L_{eq}/D L e q ​ / D )
  • Globe Valve (Fully Open) 10.0 10.0 10.0 350 350 350
  • Gate Valve (Fully Open) 0.15 0.15 0.15 8 8 8
  • Check Valve (Swing Type) 2.0 2.0 2.0 100 100 100
  • 90° Standard Elbow 0.90 0.90 0.90 30 30 30
  • 90° Long Radius Elbow 0.60 0.60 0.60 20 20 20
  • Tee (Line Flow / Branch Flow) 0.60 / 1.80 0.60 / 1.80 0.60/1.80 20 / 60 20 / 60 20/60
  • Sharp-Edged Entrance / Rounded 0.50 / 0.04 0.50 / 0.04 0.50/0.04 16 / 1 16 / 1 16/1
  • Submerged Exit (Pipe to Tank) 1.00 1.00 1.00 30 30 30
  • 4. Series and Parallel Piping Systems
  • Series Pipes

Pipes of different diameters/lengths connected end-to-end:

Continuity: Q 1 = Q 2 = Q 3 = Q t o t a l Q_1 = Q_2 = Q_3 = Q_{total} Q 1 ​ = Q 2 ​ = Q 3 ​ = Q t o t a l ​

Total Head Loss: Sum of major and minor head losses across all segments: h L , t o t a l = ∑ h f , i + ∑ h m , i h_{L,total} = \sum h_{f,i} + \sum h_{m,i} h L , t o t a l ​ = ∑ h f , i ​ + ∑ h m , i ​

Parallel Pipes

Pipes splitting at a junction and rejoining downstream:

Continuity: Q t o t a l = Q 1 + Q 2 + Q 3 + ⋯ + Q n Q_{total} = Q_1 + Q_2 + Q_3 + \dots + Q_n Q t o t a l ​ = Q 1 ​ + Q 2 ​ + Q 3 ​ + ⋯ + Q n ​

Equal Head Loss: Head loss across every parallel branch is identical: h L , b r a n c h 1 = h L , b r a n c h 2 = h L , b r a n c h 3 = Δ H j u n c t i o n s h_{L,branch 1} = h_{L,branch 2} = h_{L,branch 3} = \Delta H_{junctions} h L , b r an c h 1 ​ = h L , b r an c h 2 ​ = h L , b r an c h 3 ​ = Δ H j u n c t i o n s ​

Flow Split Ratio: For turbulent flow where h f = r Q 2 h_f = r Q^2 h f ​ = r Q 2 : Q 1 Q 2 = r 2 r 1 = f 2 L 2 D 1 5 f 1 L 1 D 2 5 \frac{Q_1}{Q_2} = \sqrt{\frac{r_2}{r_1}} = \sqrt{\frac{f_2 L_2 D_1^5}{f_1 L_1 D_2^5}} Q 2 ​ Q 1 ​ ​ = r 1 ​ r 2 ​ ​ ​ = f 1 ​ L 1 ​ D 2 5 ​ f 2 ​ L 2 ​ D 1 5 ​ ​ ​

5. Piping Network Analysis & Hardy Cross Method

Complex municipal and industrial pipe networks containing closed loops are analyzed by enforcing two fundamental laws:

Junction Law (Continuity): Total flow entering a junction equals total flow leaving: ∑ Q i n = ∑ Q o u t \sum Q_{in} = \sum Q_{out} ∑ Q in ​ = ∑ Q o u t ​ .

Loop Law (Energy Conservation): Algebraic sum of head losses around any closed loop must equal zero: ∑ h L = 0 \sum h_L = 0 ∑ h L ​ = 0 .

Expressing branch head loss as h f = r Q ∣ Q ∣ n − 1 h_f = r Q |Q|^{n-1} h f ​ = r Q ∣ Q ∣ n − 1 (where n = 2 n=2 n = 2 for Darcy-Weisbach or n = 1.852 n=1.852 n = 1.852 for Hazen-Williams), the Hardy Cross Method applies an iterative flow correction Δ Q \Delta Q Δ Q to each loop: Δ Q = − ∑ r Q ∣ Q ∣ n − 1 n ∑ r ∣ Q ∣ n − 2 = − ∑ h L n ∑ ∣ h L Q ∣ \Delta Q = - \frac{\sum r Q |Q|^{n-1}}{n \sum r |Q|^{n-2}} = - \frac{\sum h_L}{n \sum \left| \frac{h_L}{Q} \right|} Δ Q = − n ∑ r ∣ Q ∣ n − 2 ∑ r Q ∣ Q ∣ n − 1 ​ = − n ∑ ​ Q h L ​ ​ ​ ∑ h L ​ ​

6. Water Hammer Phenomenon & Surge Control

Water hammer is a severe hydraulic pressure surge created when fluid velocity in a pipeline changes rapidly (e.g., sudden valve closure or pump trip).

Acoustic Wave Speed (Celerity c c c ): c = K / ρ 1 + K ⋅ D E ⋅ t c = \sqrt{\frac{K/\rho}{1 + \frac{K \cdot D}{E \cdot t}}} c = 1 + E ⋅ t K ⋅ D ​ K / ρ ​ ​

where K K K is fluid bulk modulus ( 2.19 GPa 2.19\text{ GPa} 2.19 GPa for water), ρ \rho ρ is fluid density, E E E is pipe material modulus of elasticity, D D D is pipe diameter, and t t t is wall thickness. For rigid steel water pipes, c ≈ 1000 − 1200 m/s c \approx 1000 - 1200\text{ m/s} c ≈ 1000 − 1200 m/s .

Critical Valve Closure Time ( t c t_c t c ​ ):

Rapid (Instantaneous) Closure: t c l o s u r e ≤ 2 L c t_{closure} \le \frac{2L}{c} t c l os u re ​ ≤ c 2 L ​ (acoustic pressure wave reflects before valve closes).

Slow Closure: t c l o s u r e > 2 L c t_{closure} > \frac{2L}{c} t c l os u re ​ > c 2 L ​ .

Joukowsky Equation for Rapid Closure:

Maximum transient pressure surge magnitude Δ P m a x \Delta P_{max} Δ P ma x ​ : Δ P m a x = ρ c Δ V \Delta P_{max} = \rho c \Delta V Δ P ma x ​ = ρ c Δ V Δ H m a x = c Δ V g \Delta H_{max} = \frac{c \Delta V}{g} Δ H ma x ​ = g c Δ V ​

where Δ V = V i n i t i a l − V f i n a l \Delta V = V_{initial} - V_{final} Δ V = V ini t ia l ​ − V f ina l ​ . Total peak pipeline pressure is P p e a k = P o p e r a t i n g + Δ P m a x P_{peak} = P_{operating} + \Delta P_{max} P p e ak ​ = P o p er a t in g ​ + Δ P ma x ​ .

Water Hammer Mitigation Techniques:

Increase valve closure time ( t c l o s u r e ≫ 2 L / c t_{closure} \gg 2L/c t c l os u re ​ ≫ 2 L / c ).

Install Surge Tanks or pressurized Air Chambers near quick-closing valves.

Position quick-opening Pressure Relief Valves and Vacuum Breakers .

  • 7. Worked Numerical Examples
  • Example 1: Major & Minor Losses via Swamee-Jain

Water ( ρ = 1000 kg/m 3 \rho = 1000\text{ kg/m}^3 ρ = 1000 kg/m 3 , ν = 1.00 × 10 − 6 m 2 / s \nu = 1.00 \times 10^{-6}\text{ m}^2/\text{s} ν = 1.00 × 1 0 − 6 m 2 / s ) flows through a D = 200 mm D = 200\text{ mm} D = 200 mm commercial steel pipe ( ε = 0.045 mm \varepsilon = 0.045\text{ mm} ε = 0.045 mm ) of length L = 400 m L = 400\text{ m} L = 400 m at a volumetric rate of Q = 0.060 m 3 / s Q = 0.060\text{ m}^3/\text{s} Q = 0.060 m 3 / s . The line includes two open gate valves ( K = 0.15 K = 0.15 K = 0.15 each), four 90° standard elbows ( K = 0.90 K = 0.90 K = 0.90 each), and a sharp entrance ( K = 0.50 K = 0.50 K = 0.50 ). Calculate:

Reynolds number R e Re R e and flow regime.

Darcy friction factor f f f using Swamee-Jain.

Total head loss h L , t o t a l h_{L,total} h L , t o t a l ​ .

Solution Step-by-Step:

Step 1: Calculate velocity and Reynolds number: A = π ( 0.20 ) 2 4 = 0.031416 m 2 A = \frac{\pi (0.20)^2}{4} = 0.031416\text{ m}^2 A = 4 π ( 0.20 ) 2 ​ = 0.031416 m 2 V = Q A = 0.060 0.031416 = 1.90986 m/s V = \frac{Q}{A} = \frac{0.060}{0.031416} = 1.90986\text{ m/s} V = A Q ​ = 0.031416 0.060 ​ = 1.90986 m/s R e = V D ν = 1.90986 × 0.20 1.00 × 10 − 6 = 381 , 972 ( Turbulent flow, R e > 4000 ) Re = \frac{V D}{\nu} = \frac{1.90986 \times 0.20}{1.00 \times 10^{-6}} = 381,972 \quad (\text{Turbulent flow, } Re > 4000) R e = ν V D ​ = 1.00 × 1 0 − 6 1.90986 × 0.20 ​ = 381 , 972 ( Turbulent flow, R e > 4000 )

Step 2: Calculate relative roughness and Swamee-Jain friction factor f f f : ε D = 0.045 mm 200 mm = 0.000225 \frac{\varepsilon}{D} = \frac{0.045\text{ mm}}{200\text{ mm}} = 0.000225 D ε ​ = 200 mm 0.045 mm ​ = 0.000225 f = 0.25 [ log ⁡ 10 ( 0.000225 3.7 + 5.74 ( 381 , 972 ) 0.9 ) ] 2 f = \frac{0.25}{\left[ \log_{10} \left( \frac{0.000225}{3.7} + \frac{5.74}{(381,972)^{0.9}} \right) \right]^2} f = [ lo g 10 ​ ( 3.7 0.000225 ​ + ( 381 , 972 ) 0.9 5.74 ​ ) ] 2 0.25 ​ 0.000225 3.7 = 6.081 × 10 − 5 , 5.74 106 , 711 = 5.379 × 10 − 5 \frac{0.000225}{3.7} = 6.081 \times 10^{-5}, \quad \frac{5.74}{106,711} = 5.379 \times 10^{-5} 3.7 0.000225 ​ = 6.081 × 1 0 − 5 , 106 , 711 5.74 ​ = 5.379 × 1 0 − 5 Sum = 1.1460 × 10 − 4 ⟹ log ⁡ 10 ( 1.1460 × 10 − 4 ) = − 3.9408 \text{Sum} = 1.1460 \times 10^{-4} \implies \log_{10}(1.1460 \times 10^{-4}) = -3.9408 Sum = 1.1460 × 1 0 − 4 ⟹ lo g 10 ​ ( 1.1460 × 1 0 − 4 ) = − 3.9408 f = 0.25 ( − 3.9408 ) 2 = 0.25 15.530 = 0.016098 f = \frac{0.25}{(-3.9408)^2} = \frac{0.25}{15.530} = 0.016098 f = ( − 3.9408 ) 2 0.25 ​ = 15.530 0.25 ​ = 0.016098

Step 3: Calculate major head loss h f h_f h f ​ and minor head loss h m h_m h m ​ : V 2 2 g = ( 1.90986 ) 2 2 ( 9.81 ) = 3.6476 19.62 = 0.18591 m \frac{V^2}{2g} = \frac{(1.90986)^2}{2(9.81)} = \frac{3.6476}{19.62} = 0.18591\text{ m} 2 g V 2 ​ = 2 ( 9.81 ) ( 1.90986 ) 2 ​ = 19.62 3.6476 ​ = 0.18591 m h f = f L D V 2 2 g = 0.016098 × ( 400 0.20 ) × 0.18591 = 0.016098 × 2000 × 0.18591 = 59.86 m h_f = f \frac{L}{D} \frac{V^2}{2g} = 0.016098 \times \left(\frac{400}{0.20}\right) \times 0.18591 = 0.016098 \times 2000 \times 0.18591 = 59.86\text{ m} h f ​ = f D L ​ 2 g V 2 ​ = 0.016098 × ( 0.20 400 ​ ) × 0.18591 = 0.016098 × 2000 × 0.18591 = 59.86 m ∑ K = 0.50 + 2 ( 0.15 ) + 4 ( 0.90 ) = 0.50 + 0.30 + 3.60 = 4.40 \sum K = 0.50 + 2(0.15) + 4(0.90) = 0.50 + 0.30 + 3.60 = 4.40 ∑ K = 0.50 + 2 ( 0.15 ) + 4 ( 0.90 ) = 0.50 + 0.30 + 3.60 = 4.40 h m = ∑ K V 2 2 g = 4.40 × 0.18591 = 0.818 m h_m = \sum K \frac{V^2}{2g} = 4.40 \times 0.18591 = 0.818\text{ m} h m ​ = ∑ K 2 g V 2 ​ = 4.40 × 0.18591 = 0.818 m h L , t o t a l = h f + h m = 59.86 + 0.818 = 60.68 m h_{L,total} = h_f + h_m = 59.86 + 0.818 = 60.68\text{ m} h L , t o t a l ​ = h f ​ + h m ​ = 59.86 + 0.818 = 60.68 m

Example 2: Flow Distribution in Parallel Pipes

Two pipes connect Reservoir A to Reservoir B in parallel. Pipe 1 is steel with D 1 = 250 mm D_1 = 250\text{ mm} D 1 ​ = 250 mm , L 1 = 600 m L_1 = 600\text{ m} L 1 ​ = 600 m , f 1 = 0.018 f_1 = 0.018 f 1 ​ = 0.018 . Pipe 2 is cast iron with D 2 = 200 mm D_2 = 200\text{ mm} D 2 ​ = 200 mm , L 2 = 400 m L_2 = 400\text{ m} L 2 ​ = 400 m , f 2 = 0.022 f_2 = 0.022 f 2 ​ = 0.022 . If the total flow rate required is Q t o t a l = 0.150 m 3 / s Q_{total} = 0.150\text{ m}^3/\text{s} Q t o t a l ​ = 0.150 m 3 / s , calculate individual flow rates Q 1 Q_1 Q 1 ​ and Q 2 Q_2 Q 2 ​ .

Solution Step-by-Step:

Step 1: Set head loss of Pipe 1 equal to Pipe 2: h f 1 = h f 2 ⟹ 8 f 1 L 1 Q 1 2 π 2 g D 1 5 = 8 f 2 L 2 Q 2 2 π 2 g D 2 5 h_{f1} = h_{f2} \implies \frac{8 f_1 L_1 Q_1^2}{\pi^2 g D_1^5} = \frac{8 f_2 L_2 Q_2^2}{\pi^2 g D_2^5} h f 1 ​ = h f 2 ​ ⟹ π 2 g D 1 5 ​ 8 f 1 ​ L 1 ​ Q 1 2 ​ ​ = π 2 g D 2 5 ​ 8 f 2 ​ L 2 ​ Q 2 2 ​ ​ Q 1 2 ( f 1 L 1 D 1 5 ) = Q 2 2 ( f 2 L 2 D 2 5 ) ⟹ Q 1 Q 2 = f 2 L 2 D 1 5 f 1 L 1 D 2 5 Q_1^2 \left( \frac{f_1 L_1}{D_1^5} \right) = Q_2^2 \left( \frac{f_2 L_2}{D_2^5} \right) \implies \frac{Q_1}{Q_2} = \sqrt{\frac{f_2 L_2 D_1^5}{f_1 L_1 D_2^5}} Q 1 2 ​ ( D 1 5 ​ f 1 ​ L 1 ​ ​ ) = Q 2 2 ​ ( D 2 5 ​ f 2 ​ L 2 ​ ​ ) ⟹ Q 2 ​ Q 1 ​ ​ = f 1 ​ L 1 ​ D 2 5 ​ f 2 ​ L 2 ​ D 1 5 ​ ​ ​

Step 2: Compute numerical factors: D 1 5 = ( 0.25 ) 5 = 0.00097656 m 5 , D 2 5 = ( 0.20 ) 5 = 0.00032000 m 5 D_1^5 = (0.25)^5 = 0.00097656\text{ m}^5, \quad D_2^5 = (0.20)^5 = 0.00032000\text{ m}^5 D 1 5 ​ = ( 0.25 ) 5 = 0.00097656 m 5 , D 2 5 ​ = ( 0.20 ) 5 = 0.00032000 m 5 f 2 L 2 D 1 5 f 1 L 1 D 2 5 = 0.022 × 400 × 0.00097656 0.018 × 600 × 0.00032000 = 0.0085937 0.0034560 = 2.4866 \frac{f_2 L_2 D_1^5}{f_1 L_1 D_2^5} = \frac{0.022 \times 400 \times 0.00097656}{0.018 \times 600 \times 0.00032000} = \frac{0.0085937}{0.0034560} = 2.4866 f 1 ​ L 1 ​ D 2 5 ​ f 2 ​ L 2 ​ D 1 5 ​ ​ = 0.018 × 600 × 0.00032000 0.022 × 400 × 0.00097656 ​ = 0.0034560 0.0085937 ​ = 2.4866 Q 1 Q 2 = 2.4866 = 1.5769 ⟹ Q 1 = 1.5769 Q 2 \frac{Q_1}{Q_2} = \sqrt{2.4866} = 1.5769 \implies Q_1 = 1.5769 Q_2 Q 2 ​ Q 1 ​ ​ = 2.4866 ​ = 1.5769 ⟹ Q 1 ​ = 1.5769 Q 2 ​

Step 3: Apply continuity equation Q 1 + Q 2 = Q t o t a l Q_1 + Q_2 = Q_{total} Q 1 ​ + Q 2 ​ = Q t o t a l ​ : 1.5769 Q 2 + Q 2 = 0.150 ⟹ 2.5769 Q 2 = 0.150 1.5769 Q_2 + Q_2 = 0.150 \implies 2.5769 Q_2 = 0.150 1.5769 Q 2 ​ + Q 2 ​ = 0.150 ⟹ 2.5769 Q 2 ​ = 0.150 Q 2 = 0.150 2.5769 = 0.05821 m 3 / s = 58.21 L/s Q_2 = \frac{0.150}{2.5769} = 0.05821\text{ m}^3/\text{s} = 58.21\text{ L/s} Q 2 ​ = 2.5769 0.150 ​ = 0.05821 m 3 / s = 58.21 L/s Q 1 = 0.150 − 0.05821 = 0.09179 m 3 / s = 91.79 L/s Q_1 = 0.150 - 0.05821 = 0.09179\text{ m}^3/\text{s} = 91.79\text{ L/s} Q 1 ​ = 0.150 − 0.05821 = 0.09179 m 3 / s = 91.79 L/s

Example 3: Water Hammer Peak Pressure & Stress

A steel penstock ( D = 500 mm D = 500\text{ mm} D = 500 mm , wall thickness t = 10 mm t = 10\text{ mm} t = 10 mm ) carries water ( ρ = 1000 kg/m 3 \rho = 1000\text{ kg/m}^3 ρ = 1000 kg/m 3 , K = 2.19 GPa K = 2.19\text{ GPa} K = 2.19 GPa ) at a velocity of V = 3.0 m/s V = 3.0\text{ m/s} V = 3.0 m/s from a dam. Modulus of elasticity of steel is E = 200 GPa E = 200\text{ GPa} E = 200 GPa . A turbine valve at the downstream end ( L = 1200 m L = 1200\text{ m} L = 1200 m ) is closed in t c = 1.50 s t_c = 1.50\text{ s} t c ​ = 1.50 s . Compute:

Acoustic wave speed c c c .

Maximum pressure surge Δ P m a x \Delta P_{max} Δ P ma x ​ .

Hoop stress σ h \sigma_h σ h ​ induced in the pipe wall.

Solution Step-by-Step:

Step 1: Calculate acoustic wave speed c c c : c = K / ρ 1 + K ⋅ D E ⋅ t = ( 2.19 × 10 9 ) / 1000 1 + ( 2.19 × 10 9 ) ( 0.500 ) ( 200 × 10 9 ) ( 0.010 ) = 2.19 × 10 6 1 + 1.095 × 10 9 2.00 × 10 9 c = \sqrt{\frac{K/\rho}{1 + \frac{K \cdot D}{E \cdot t}}} = \sqrt{\frac{(2.19 \times 10^9) / 1000}{1 + \frac{(2.19 \times 10^9)(0.500)}{(200 \times 10^9)(0.010)}}}=\sqrt{\frac{2.19 \times 10^6}{1 + \frac{1.095 \times 10^9}{2.00 \times 10^9}}} c = 1 + E ⋅ t K ⋅ D ​ K / ρ ​ ​ = 1 + ( 200 × 1 0 9 ) ( 0.010 ) ( 2.19 × 1 0 9 ) ( 0.500 ) ​ ( 2.19 × 1 0 9 ) /1000 ​ ​ = 1 + 2.00 × 1 0 9 1.095 × 1 0 9 ​ 2.19 × 1 0 6 ​ ​ c = 2.19 × 10 6 1 + 0.5475 = 2 , 190 , 000 1.5475 = 1 , 415 , 185 = 1189.6 m/s c = \sqrt{\frac{2.19 \times 10^6}{1 + 0.5475}} = \sqrt{\frac{2,190,000}{1.5475}} = \sqrt{1,415,185} = 1189.6\text{ m/s} c = 1 + 0.5475 2.19 × 1 0 6 ​ ​ = 1.5475 2 , 190 , 000 ​ ​ = 1 , 415 , 185 ​ = 1189.6 m/s

Step 2: Check critical closure time: t c r i t i c a l = 2 L c = 2 × 1200 1189.6 = 2.0175 s t_{critical} = \frac{2L}{c} = \frac{2 \times 1200}{1189.6} = 2.0175\text{ s} t cr i t i c a l ​ = c 2 L ​ = 1189.6 2 × 1200 ​ = 2.0175 s

Since closure time t c = 1.50 s < t c r i t i c a l = 2.0175 s t_c = 1.50\text{ s} < t_{critical} = 2.0175\text{ s} t c ​ = 1.50 s < t cr i t i c a l ​ = 2.0175 s , closure is rapid !

Step 3: Calculate Joukowsky pressure surge Δ P m a x \Delta P_{max} Δ P ma x ​ and hoop stress: Δ P m a x = ρ c Δ V = ( 1000 kg/m 3 ) ( 1189.6 m/s ) ( 3.0 m/s ) = 3 , 568 , 800 Pa = 3.569 MPa \Delta P_{max} = \rho c \Delta V = (1000\text{ kg/m}^3)(1189.6\text{ m/s})(3.0\text{ m/s}) = 3,568,800\text{ Pa} = 3.569\text{ MPa} Δ P ma x ​ = ρ c Δ V = ( 1000 kg/m 3 ) ( 1189.6 m/s ) ( 3.0 m/s ) = 3 , 568 , 800 Pa = 3.569 MPa σ h = Δ P ⋅ D 2 t = ( 3.5688 MPa ) ( 500 mm ) 2 ( 10 mm ) = 89.22 MPa \sigma_h = \frac{\Delta P \cdot D}{2t} = \frac{(3.5688\text{ MPa})(500\text{ mm})}{2(10\text{ mm})} = 89.22\text{ MPa} σ h ​ = 2 t Δ P ⋅ D ​ = 2 ( 10 mm ) ( 3.5688 MPa ) ( 500 mm ) ​ = 89.22 MPa