Study guide

5.2 Natural & Forced Convection Heat Transfer Correlations

PRC Mechanical Engineer Licensure Examination MELE

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Licensing Overview, Law & Professional Ethics

1.1 MELE Facts, RA 8495 & Board Organization 1.2 Code of Ethics for Mechanical Engineers & Professional Practice 1.3 Philippine Mechanical Engineering Code (PME Code) Governance & Legal Mandates

2 Chapter 2: Advanced Mathematics & Engineering Statistics

2.1 Differential & Integral Calculus in Engineering Applications 2.2 Differential Equations & Mathematical Modeling 2.3 Applied Engineering Statistics & Quality Control Probability

3 Chapter 3: Engineering Thermodynamics

3.1 Thermodynamic State Postulate, Properties & P-V-T Equations of State 3.2 First Law Analysis for Open & Closed Thermal Systems 3.3 Second Law, Entropy, Exergy & Reversibility Analysis

4 Chapter 4: Fluid Mechanics & Hydraulic Engineering

4.1 Fluid Statics, Manometry, Hydrostatic Force & Buoyancy 4.2 Fluid Kinematics, Dynamics & Bernoulli Equation 4.3 Pipe Flow, Friction Losses & Piping Network Analysis

5 Chapter 5: Heat Transfer & Thermal Systems

5.1 Conduction Heat Transfer & Thermal Insulation Design 5.2 Natural & Forced Convection Heat Transfer Correlations 5.3 Thermal Radiation & Industrial Heat Exchanger Design

6 Chapter 6: Mechanics & Strength of Materials

6.1 Statics & Dynamics of Rigid Bodies & Engineering Linkages 6.2 Normal, Shear & Triaxial Stress-Strain Relationships 6.3 Bending Stresses, Torsion & Column Buckling Analysis

7 Chapter 7: Engineering Economics & Financial Analysis

7.1 Time Value of Money & Cash Flow Equivalence Formulas 7.2 Asset Depreciation, Taxation & Economic Evaluation Methods 7.3 Break-Even Analysis, Payback Period & EOQ Inventory Models

8 Chapter 8: Engineering Materials & Metallurgy

8.1 Ferrous & Non-Ferrous Metals, Alloys & Polymers 8.2 Phase Diagrams, Iron-Carbon System & Heat Treatment 8.3 Mechanical Testing, Fatigue Failure & Fracture Mechanics

9 Chapter 9: Machine Elements & Stress Analysis

9.1 Failure Theories, Static & Fluctuating Stress Design 9.2 Power Transmission Shafts, Keys & Rigid/Flexible Couplings 9.3 Spur, Helical, Bevel & Worm Gear Design Calculations

10 Chapter 10: Power Transmission Components

10.1 Belts, V-Belts, Chains, Wire Ropes & Flywheels 10.2 Rolling Element & Hydrodynamic Journal Bearings 10.3 Mechanical Springs, Clutches & Industrial Brakes

11 Chapter 11: Manufacturing, Fasteners & GD&T

11.1 Threaded Fasteners, Rivets & Welded Joint Analysis 11.2 Manufacturing Processes, Machine Tools & Machining Calculations 11.3 Engineering Drawing, Limits, Fits, Tolerances & GD&T

12 Chapter 12: Power Plants, Boilers & Thermal Power Cycles

12.1 Steam Power Plants & Rankine Cycles 12.2 Steam Generators, Boilers & Combustion Engineering 12.3 Internal Combustion Engines: SI & CI Cycles 12.4 Gas Turbine Power Plants & Combined Cycles

13 Chapter 13: Renewable Energy, Fluid Machinery & Plant Systems

13.1 Hydroelectric, Geothermal & Renewable Energy Power Plants 13.2 Pumps & Hydraulic Machinery 13.3 Air Compressors, Fans & Blowers

14 Chapter 14: Refrigeration, HVAC & Building Mechanical Systems

14.1 Refrigeration Systems, Cycles & Refrigerants 14.2 Psychrometrics & Air Conditioning Systems 14.3 Piping/Ductwork Design, PME Code & Industrial Safety Management

5.2 Natural & Forced Convection Heat Transfer Correlations

Key Takeaways Explain This Topic AI

Newton's Law of Cooling defines convective heat transfer rate as q = h A (T_s - T_infinity), where convective coefficient h is determined by fluid flow dynamics and thermal properties.

Boundary layer theory establishes that velocity boundary layer thickness delta is controlled by viscous diffusion, while thermal boundary layer delta_t is controlled by thermal diffusion, linked by Prandtl number Pr = nu / alpha.

Key dimensionless parameters governing convection include Reynolds (Re = V L / nu), Prandtl (Pr = nu / alpha), Nusselt (Nu = h L / k_f), Grashof (Gr = g beta DeltaT L^3 / nu^2), and Rayleigh (Ra = Gr * Pr).

Forced internal flow inside tubes utilizes the Dittus-Boelter equation Nu_D = 0.023 Re_D^0.8 Pr^n (n = 0.4 for heating, n = 0.3 for cooling) for turbulent fully developed flow (Re_D > 10,000).

The relative magnitude of Gr_L / Re_L^2 dictates the convection mechanism: Gr_L / Re_L^2 << 1 forced convection dominates; Gr_L / Re_L^2 >> 1 free convection dominates; Gr_L / Re_L^2 ~ 1 mixed convection occurs.

Last updated: July 2026

5.2 Natural & Forced Convection Heat Transfer Correlations

Convective heat transfer occurs between a solid surface and an adjacent moving fluid (liquid or gas) at different temperatures. Convection is classified into forced convection , where fluid motion is driven by external mechanical means (pumps, fans, blowers, or wind), and natural (free) convection , where fluid motion is induced by buoyancy forces arising from density gradients caused by temperature variations in a body force (gravitational) field.

1. Newton's Law of Cooling & Boundary Layer Fundamentals

The fundamental rate equation for convective heat transfer is Newton's Law of Cooling : q = h A s ( T s − T ∞ ) q = h A_s (T_s - T_\infty) q = h A s ​ ( T s ​ − T ∞ ​ )

Where:

q q q = Convective heat transfer rate ( W \text{W} W )

h h h = Convective heat transfer coefficient ( W/m 2 ⋅ K \text{W/m}^2\cdot\text{K} W/m 2 ⋅ K or W/m 2 ⋅ ∘ C \text{W/m}^2\cdot^\circ\text{C} W/m 2 ⋅ ∘ C )

  • A s A_s A s ​ = Surface area in contact with fluid ( m 2 \text{m}^2 m 2 )
  • T s T_s T s ​ = Solid surface temperature ( K \text{K} K or ∘ C ^\circ\text{C} ∘ C )
  • T ∞ T_\infty T ∞ ​ = Free-stream (or bulk fluid) temperature ( K \text{K} K or ∘ C ^\circ\text{C} ∘ C )
  • Boundary Layer Theory

When a fluid flows over a solid surface, fluid particles adjacent to the wall adhere due to viscous forces, creating a no-slip condition ( u ( y = 0 ) = 0 u(y=0) = 0 u ( y = 0 ) = 0 ).

Velocity (Hydrodynamic) Boundary Layer ( δ \delta δ ) : Region of fluid flow where velocity gradients exist normal to the surface, defined as the distance from wall y = δ y = \delta y = δ where u ( y ) = 0.99 U ∞ u(y) = 0.99 U_\infty u ( y ) = 0.99 U ∞ ​ .

Thermal Boundary Layer ( δ t \delta_t δ t ​ ) : Region where fluid temperature gradients exist, defined as distance y = δ t y = \delta_t y = δ t ​ where T ( y ) − T s T ∞ − T s = 0.99 \frac{T(y) - T_s}{T_\infty - T_s} = 0.99 T ∞ ​ − T s ​ T ( y ) − T s ​ ​ = 0.99 .

The relative thickness of velocity and thermal boundary layers is governed by the Prandtl number ( P r Pr P r ): δ δ t ≈ P r n ( n ≈ 1 / 3 \frac{\delta}{\delta_t} \approx Pr^n \quad (n \approx 1/3 δ t ​ δ ​ ≈ P r n ( n ≈ 1/3

2. Key Dimensionless Groups in Convective Heat Transfer

To standardize empirical correlations independent of fluid type or physical scale, heat transfer analysis relies on dimensionless numbers:

Dimensionless Group Formula Physical Significance / Interpretation

Reynolds Number ( R e L Re_L R e L ​ ) R e L = ρ V L μ = V L ν Re_L = \frac{\rho V L}{\mu} = \frac{V L}{\nu} R e L ​ = μ ρ V L ​ = ν V L ​ Ratio of inertia forces to viscous forces in forced flow

Prandtl Number ( P r Pr P r ) P r = ν α = μ c p k f Pr = \frac{\nu}{\alpha} = \frac{\mu c_p}{k_f} P r = α ν ​ = k f ​ μ c p ​ ​ Ratio of momentum diffusivity to thermal diffusivity

Nusselt Number ( N u L Nu_L N u L ​ ) N u L = h L k f Nu_L = \frac{h L}{k_f} N u L ​ = k f ​ h L ​ Ratio of convective heat transfer to pure fluid conduction

Grashof Number ( G r L Gr_L G r L ​ ) G r L = g β ( T s − T ∞ ) L 3 ν 2 Gr_L = \frac{g \beta (T_s - T_\infty) L^3}{\nu^2} G r L ​ = ν 2 g β ( T s ​ − T ∞ ​ ) L 3 ​ Ratio of buoyancy forces to viscous forces in free flow

Rayleigh Number ( R a L Ra_L R a L ​ ) R a L = G r L ⋅ P r = g β ( T s − T ∞ ) L 3 ν α Ra_L = Gr_L \cdot Pr = \frac{g \beta (T_s - T_\infty) L^3}{\nu \alpha} R a L ​ = G r L ​ ⋅ P r = να g β ( T s ​ − T ∞ ​ ) L 3 ​ Product of Grashof and Prandtl numbers; dictates free convection transition

Stanton Number ( S t St St ) S t = N u L R e L P r = h ρ c p V St = \frac{Nu_L}{Re_L Pr} = \frac{h}{\rho c_p V} St = R e L ​ P r N u L ​ ​ = ρ c p ​ V h ​ Ratio of heat transferred to thermal capacity of fluid

Volumetric Thermal Expansion Coefficient ( β \beta β )

For ideal gases, the thermal expansion coefficient β \beta β is evaluated using absolute film temperature T f T_f T f ​ in Kelvin: β = 1 T f = 1 T s + T ∞ 2 + 273.15 [ K − 1 ] \beta = \frac{1}{T_f} = \frac{1}{\frac{T_s + T_\infty}{2} + 273.15} \quad [\text{K}^{-1}] β = T f ​ 1 ​ = 2 T s ​ + T ∞ ​ ​ + 273.15 1 ​ [ K − 1 ]

  • 3. Forced Convection Correlations for Internal & External Flows
  • Forced Flow Inside Tubes and Pipes (Internal Flow)

Flow regime transition in smooth circular pipes occurs at critical Reynolds number R e D , c ≈ 2300 Re_{D,c} \approx 2300 R e D , c ​ ≈ 2300 .

Laminar Fully Developed Flow ( R e D < 2300 Re_D < 2300 R e D ​ < 2300 ) :

Constant Surface Temperature ( T s = const T_s = \text{const} T s ​ = const ): N u D = h D k f = 3.66 Nu_D = \frac{h D}{k_f} = 3.66 N u D ​ = k f ​ h D ​ = 3.66

Constant Surface Heat Flux ( q ′ ′ = const q'' = \text{const} q ′′ = const ): N u D = h D k f = 4.36 Nu_D = \frac{h D}{k_f} = 4.36 N u D ​ = k f ​ h D ​ = 4.36

Turbulent Fully Developed Flow ( R e D > 10 , 000 , 0.6 ≤ P r ≤ 160 , L / D ≥ 10 Re_D > 10,000, 0.6 \le Pr \le 160, L/D \ge 10 R e D ​ > 10 , 000 , 0.6 ≤ P r ≤ 160 , L / D ≥ 10 ) : Dittus-Boelter Correlation : N u D = 0.023 R e D 0.8 P r n Nu_D = 0.023 Re_D^{0.8} Pr^n N u D ​ = 0.023 R e D 0.8 ​ P r n

Where:

  • n = 0.4 n = 0.4 n = 0.4 for heating of the fluid ( T s > T b T_s > T_b T s ​ > T b ​ )
  • n = 0.3 n = 0.3 n = 0.3 for cooling of the fluid ( T s < T b T_s < T_b T s ​ < T b ​ )

All fluid properties are evaluated at the bulk mean temperature T b = T i n + T o u t 2 T_b = \frac{T_{in} + T_{out}}{2} T b ​ = 2 T in ​ + T o u t ​ ​ .

Sieder-Tate Correlation (for large property variations due to steep temperature gradients): N u D = 0.027 R e D 0.8 P r 1 / 3 ( μ b μ s ) 0.14 Nu_D = 0.027 Re_D^{0.8} Pr^{1/3} \left( \frac{\mu_b}{\mu_s} \right)^{0.14} N u D ​ = 0.027 R e D 0.8 ​ P r 1/3 ( μ s ​ μ b ​ ​ ) 0.14

External Flow Over Flat Plates

Critical transition Reynolds number for flat plate flow is R e x , c ≈ 5 × 10 5 Re_{x,c} \approx 5 \times 10^5 R e x , c ​ ≈ 5 × 1 0 5 .

Laminar Flow ( R e x < 5 × 10 5 Re_x < 5 \times 10^5 R e x ​ < 5 × 1 0 5 ) :

Local Nusselt Number: N u x = 0.332 R e x 1 / 2 P r 1 / 3 Nu_x = 0.332 Re_x^{1/2} Pr^{1/3} N u x ​ = 0.332 R e x 1/2 ​ P r 1/3

Average Nusselt Number over length L L L : N u ‾ L = 0.664 R e L 1 / 2 P r 1 / 3 \overline{Nu}_L = 0.664 Re_L^{1/2} Pr^{1/3} N u L ​ = 0.664 R e L 1/2 ​ P r 1/3

Mixed / Combined Boundary Layer ( R e L > 5 × 10 5 Re_L > 5 \times 10^5 R e L ​ > 5 × 1 0 5 ) : N u ‾ L = ( 0.037 R e L 4 / 5 − 871 ) P r 1 / 3 \overline{Nu}_L = (0.037 Re_L^{4/5} - 871) Pr^{1/3} N u L ​ = ( 0.037 R e L 4/5 ​ − 871 ) P r 1/3

External Flow Across Single Cylinders

For cross-flow across a circular cylinder of diameter D D D , the Churchill-Bernstein Correlation applies across all R e D P r > 0.2 Re_D Pr > 0.2 R e D ​ P r > 0.2 : N u ‾ D = 0.3 + 0.62 R e D 1 / 2 P r 1 / 3 [ 1 + ( 0.4 / P r ) 2 / 3 ] 1 / 4 [ 1 + ( R e D 282 , 000 ) 5 / 8 ] 4 / 5 \overline{Nu}_D = 0.3 + \frac{0.62 Re_D^{1/2} Pr^{1/3}}{\left[ 1 + (0.4/Pr)^{2/3} \right]^{1/4}} \left[ 1 + \left( \frac{Re_D}{282,000} \right)^{5/8} \right]^{4/5} N u D ​ = 0.3 + [ 1 + ( 0.4/ P r ) 2/3 ] 1/4 0.62 R e D 1/2 ​ P r 1/3 ​ [ 1 + ( 282 , 000 R e D ​ ​ ) 5/8 ] 4/5

4. Natural (Free) Convection Correlations & Flow Regimes

In free convection, fluid motion is governed by buoyancy-driven Rayleigh number ( R a L = G r L ⋅ P r Ra_L = Gr_L \cdot Pr R a L ​ = G r L ​ ⋅ P r ). Standard correlations take the general functional form: N u ‾ L = C R a L n \overline{Nu}_L = C Ra_L^n N u L ​ = CR a L n ​

Laminar Regime ( 10 4 ≤ R a L ≤ 10 9 10^4 \le Ra_L \le 10^9 1 0 4 ≤ R a L ​ ≤ 1 0 9 ): Typically C ≈ 0.59 C \approx 0.59 C ≈ 0.59 and n = 1 / 4 = 0.25 n = 1/4 = 0.25 n = 1/4 = 0.25 .

Turbulent Regime ( 10 9 < R a L ≤ 10 13 10^9 < Ra_L \le 10^{13} 1 0 9 < R a L ​ ≤ 1 0 13 ): Typically C ≈ 0.10 C \approx 0.10 C ≈ 0.10 and n = 1 / 3 ≈ 0.333 n = 1/3 \approx 0.333 n = 1/3 ≈ 0.333 .

Vertical Plates and Cylinders

For isothermal vertical surfaces over the entire range of Rayleigh numbers, Churchill and Chu Correlation is widely utilized: N u ‾ L = { 0.825 + 0.387 R a L 1 / 6 [ 1 + ( 0.492 / P r ) 9 / 16 ] 8 / 27 } 2 \overline{Nu}_L = \left\{ 0.825 + \frac{0.387 Ra_L^{1/6}}{\left[ 1 + (0.492/Pr)^{9/16} \right]^{8/27}} \right\}^2 N u L ​ = { 0.825 + [ 1 + ( 0.492/ P r ) 9/16 ] 8/27 0.387 R a L 1/6 ​ ​ } 2

Horizontal Plates

For a horizontal plate of area A A A and perimeter P P P , characteristic length is defined as L c = A P L_c = \frac{A}{P} L c ​ = P A ​ .

Upper Surface Heated (or Lower Surface Cooled) :

Laminar ( 10 4 ≤ R a L ≤ 10 7 10^4 \le Ra_L \le 10^7 1 0 4 ≤ R a L ​ ≤ 1 0 7 ): N u ‾ L = 0.54 R a L 1 / 4 \overline{Nu}_L = 0.54 Ra_L^{1/4} N u L ​ = 0.54 R a L 1/4 ​

Turbulent ( 10 7 < R a L ≤ 10 11 10^7 < Ra_L \le 10^{11} 1 0 7 < R a L ​ ≤ 1 0 11 ): N u ‾ L = 0.15 R a L 1 / 3 \overline{Nu}_L = 0.15 Ra_L^{1/3} N u L ​ = 0.15 R a L 1/3 ​

Lower Surface Heated (or Upper Surface Cooled) :

Laminar ( 10 5 ≤ R a L ≤ 10 10 10^5 \le Ra_L \le 10^{10} 1 0 5 ≤ R a L ​ ≤ 1 0 10 ): N u ‾ L = 0.27 R a L 1 / 4 \overline{Nu}_L = 0.27 Ra_L^{1/4} N u L ​ = 0.27 R a L 1/4 ​

5. Mixed Convection & Regime Identification ( G r L / R e L 2 Gr_L / Re_L^2 G r L ​ / R e L 2 ​ )

When both external flow forcing and internal thermal buoyancy forces coexist, the relative dominance of heat transfer mode is evaluated by comparing Grashof and Reynolds numbers: G r L R e L 2 = g β ( T s − T ∞ ) L V 2 1 \frac{Gr_L}{Re_L^2} = \frac{g \beta (T_s - T_\infty) L}{\frac{V^2}{1}} R e L 2 ​ G r L ​ ​ = 1 V 2 ​ g β ( T s ​ − T ∞ ​ ) L ​

G r L R e L 2 ≪ 1 \frac{Gr_L}{Re_L^2} \ll 1 R e L 2 ​ G r L ​ ​ ≪ 1 : Pure forced convection; buoyancy effects are negligible.

G r L R e L 2 ≫ 1 \frac{Gr_L}{Re_L^2} \gg 1 R e L 2 ​ G r L ​ ​ ≫ 1 : Pure natural convection; forced flow velocity is negligible.

G r L R e L 2 ≈ 1 \frac{Gr_L}{Re_L^2} \approx 1 R e L 2 ​ G r L ​ ​ ≈ 1 : Mixed Convection ; both forced and natural convection contributions must be calculated using combined Nusselt relations: N u m i x e d n = N u f o r c e d n ± N u n a t u r a l n Nu_{mixed}^n = Nu_{forced}^n \pm Nu_{natural}^n N u mi x e d n ​ = N u f orce d n ​ ± N u na t u r a l n ​ ( n ≈ 3 n \approx 3 n ≈ 3 ).

  • 6. Step-by-Step Worked Engineering Calculation (MELE Board Exam Style)
  • Problem Statement

Water at a bulk mean temperature of T b = 40 ∘ C T_b = 40^\circ\text{C} T b ​ = 4 0 ∘ C flows inside a smooth copper pipe with an internal diameter of D = 25 mm = 0.025 m D = 25\text{ mm} = 0.025\text{ m} D = 25 mm = 0.025 m and length L = 4.0 m L = 4.0\text{ m} L = 4.0 m at a mean velocity of V = 2.0 m/s V = 2.0\text{ m/s} V = 2.0 m/s . The inner pipe wall surface is maintained at a uniform temperature of T s = 80 ∘ C T_s = 80^\circ\text{C} T s ​ = 8 0 ∘ C by external condensing steam.

Water properties at T b = 40 ∘ C T_b = 40^\circ\text{C} T b ​ = 4 0 ∘ C :

Density ρ = 992.1 kg/m 3 \rho = 992.1\text{ kg/m}^3 ρ = 992.1 kg/m 3

Dynamic viscosity μ = 0.653 × 10 − 3 N ⋅ s/m 2 \mu = 0.653 \times 10^{-3}\text{ N}\cdot\text{s/m}^2 μ = 0.653 × 1 0 − 3 N ⋅ s/m 2

  • Thermal conductivity k f = 0.631 W/m ⋅ K k_f = 0.631\text{ W/m}\cdot\text{K} k f ​ = 0.631 W/m ⋅ K
  • Prandtl number P r = 4.32 Pr = 4.32 P r = 4.32

Calculate the Reynolds number R e D Re_D R e D ​ and verify the flow regime.

Calculate the convective heat transfer coefficient h h h using the Dittus-Boelter correlation.

Determine the total heat transfer rate q q q to the water.

Solution

Step 1: Calculate Reynolds Number & Identify Flow Regime R e D = ρ V D μ = 992.1 × 2.0 × 0.025 0.653 × 10 − 3 = 49.605 0.000653 = 75 , 964.8 Re_D = \frac{\rho V D}{\mu} = \frac{992.1 \times 2.0 \times 0.025}{0.653 \times 10^{-3}} = \frac{49.605}{0.000653} = 75,964.8 R e D ​ = μ ρ V D ​ = 0.653 × 1 0 − 3 992.1 × 2.0 × 0.025 ​ = 0.000653 49.605 ​ = 75 , 964.8

Analysis: Since R e D = 75 , 965 > 10 , 000 Re_D = 75,965 > 10,000 R e D ​ = 75 , 965 > 10 , 000 , the internal flow is fully turbulent .

Step 2: Calculate Nusselt Number & Convective Coefficient

Since water is being heated ( T s = 80 ∘ C > T b = 40 ∘ C T_s = 80^\circ\text{C} > T_b = 40^\circ\text{C} T s ​ = 8 0 ∘ C > T b ​ = 4 0 ∘ C ), the Prandtl number exponent in Dittus-Boelter equation is n = 0.4 n = 0.4 n = 0.4 : N u D = 0.023 R e D 0.8 P r 0.4 Nu_D = 0.023 Re_D^{0.8} Pr^{0.4} N u D ​ = 0.023 R e D 0.8 ​ P r 0.4

Calculate terms:

R e D 0.8 = ( 75 , 964.8 ) 0.8 = 8057.06 Re_D^{0.8} = (75,964.8)^{0.8} = 8057.06 R e D 0.8 ​ = ( 75 , 964.8 ) 0.8 = 8057.06

P r 0.4 = ( 4.32 ) 0.4 = 1.7919 Pr^{0.4} = (4.32)^{0.4} = 1.7919 P r 0.4 = ( 4.32 ) 0.4 = 1.7919

Substitute into Dittus-Boelter: N u D = 0.023 × 8057.06 × 1.7919 = 332.09 Nu_D = 0.023 \times 8057.06 \times 1.7919 = 332.09 N u D ​ = 0.023 × 8057.06 × 1.7919 = 332.09

Now calculate convective heat transfer coefficient h h h : h = N u D ⋅ k f D = 332.09 × 0.631 W/m ⋅ K 0.025 m = 209.549 0.025 = 8381.96 W/m 2 ⋅ K h = \frac{Nu_D \cdot k_f}{D} = \frac{332.09 \times 0.631\text{ W/m}\cdot\text{K}}{0.025\text{ m}} = \frac{209.549}{0.025} = 8381.96\text{ W/m}^2\cdot\text{K} h = D N u D ​ ⋅ k f ​ ​ = 0.025 m 332.09 × 0.631 W/m ⋅ K ​ = 0.025 209.549 ​ = 8381.96 W/m 2 ⋅ K

Step 3: Calculate Internal Surface Area and Total Heat Rate

Internal surface area of pipe A s A_s A s ​ : A s = π D L = π × 0.025 × 4.0 = 0.31416 m 2 A_s = \pi D L = \pi \times 0.025 \times 4.0 = 0.31416\text{ m}^2 A s ​ = π D L = π × 0.025 × 4.0 = 0.31416 m 2

Calculate convective heat transfer rate q q q using Newton's Law of Cooling: q = h A s ( T s − T b ) = 8381.96 × 0.31416 × ( 80 − 40 ) q = h A_s (T_s - T_b) = 8381.96 \times 0.31416 \times (80 - 40) q = h A s ​ ( T s ​ − T b ​ ) = 8381.96 × 0.31416 × ( 80 − 40 ) q = 8381.96 × 0.31416 × 40 = 105 , 327.5 W = 105.33 kW q = 8381.96 \times 0.31416 \times 40 = 105,327.5\text{ W} = 105.33\text{ kW} q = 8381.96 × 0.31416 × 40 = 105 , 327.5 W = 105.33 kW

The total convective heat transfer rate from pipe wall to water is 105.33 kW 105.33\text{ kW} 105.33 kW .

Loading diagram... Classification of Convective Heat Transfer Regimes and Flow Conditions