Study guide
5.3 Thermal Radiation & Industrial Heat Exchanger Design
PRC Mechanical Engineer Licensure Examination MELE
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Licensing Overview, Law & Professional Ethics
1.1 MELE Facts, RA 8495 & Board Organization 1.2 Code of Ethics for Mechanical Engineers & Professional Practice 1.3 Philippine Mechanical Engineering Code (PME Code) Governance & Legal Mandates
2 Chapter 2: Advanced Mathematics & Engineering Statistics
2.1 Differential & Integral Calculus in Engineering Applications 2.2 Differential Equations & Mathematical Modeling 2.3 Applied Engineering Statistics & Quality Control Probability
3 Chapter 3: Engineering Thermodynamics
3.1 Thermodynamic State Postulate, Properties & P-V-T Equations of State 3.2 First Law Analysis for Open & Closed Thermal Systems 3.3 Second Law, Entropy, Exergy & Reversibility Analysis
4 Chapter 4: Fluid Mechanics & Hydraulic Engineering
4.1 Fluid Statics, Manometry, Hydrostatic Force & Buoyancy 4.2 Fluid Kinematics, Dynamics & Bernoulli Equation 4.3 Pipe Flow, Friction Losses & Piping Network Analysis
5 Chapter 5: Heat Transfer & Thermal Systems
5.1 Conduction Heat Transfer & Thermal Insulation Design 5.2 Natural & Forced Convection Heat Transfer Correlations 5.3 Thermal Radiation & Industrial Heat Exchanger Design
6 Chapter 6: Mechanics & Strength of Materials
6.1 Statics & Dynamics of Rigid Bodies & Engineering Linkages 6.2 Normal, Shear & Triaxial Stress-Strain Relationships 6.3 Bending Stresses, Torsion & Column Buckling Analysis
7 Chapter 7: Engineering Economics & Financial Analysis
7.1 Time Value of Money & Cash Flow Equivalence Formulas 7.2 Asset Depreciation, Taxation & Economic Evaluation Methods 7.3 Break-Even Analysis, Payback Period & EOQ Inventory Models
8 Chapter 8: Engineering Materials & Metallurgy
8.1 Ferrous & Non-Ferrous Metals, Alloys & Polymers 8.2 Phase Diagrams, Iron-Carbon System & Heat Treatment 8.3 Mechanical Testing, Fatigue Failure & Fracture Mechanics
9 Chapter 9: Machine Elements & Stress Analysis
9.1 Failure Theories, Static & Fluctuating Stress Design 9.2 Power Transmission Shafts, Keys & Rigid/Flexible Couplings 9.3 Spur, Helical, Bevel & Worm Gear Design Calculations
10 Chapter 10: Power Transmission Components
10.1 Belts, V-Belts, Chains, Wire Ropes & Flywheels 10.2 Rolling Element & Hydrodynamic Journal Bearings 10.3 Mechanical Springs, Clutches & Industrial Brakes
11 Chapter 11: Manufacturing, Fasteners & GD&T
11.1 Threaded Fasteners, Rivets & Welded Joint Analysis 11.2 Manufacturing Processes, Machine Tools & Machining Calculations 11.3 Engineering Drawing, Limits, Fits, Tolerances & GD&T
12 Chapter 12: Power Plants, Boilers & Thermal Power Cycles
12.1 Steam Power Plants & Rankine Cycles 12.2 Steam Generators, Boilers & Combustion Engineering 12.3 Internal Combustion Engines: SI & CI Cycles 12.4 Gas Turbine Power Plants & Combined Cycles
13 Chapter 13: Renewable Energy, Fluid Machinery & Plant Systems
13.1 Hydroelectric, Geothermal & Renewable Energy Power Plants 13.2 Pumps & Hydraulic Machinery 13.3 Air Compressors, Fans & Blowers
14 Chapter 14: Refrigeration, HVAC & Building Mechanical Systems
14.1 Refrigeration Systems, Cycles & Refrigerants 14.2 Psychrometrics & Air Conditioning Systems 14.3 Piping/Ductwork Design, PME Code & Industrial Safety Management
5.3 Thermal Radiation & Industrial Heat Exchanger Design
Key Takeaways Explain This Topic AI
Stefan-Boltzmann law states blackbody emissive power is Eb = sigma * T^4 (sigma = 5.670374 x 10^-8 W/m²·K^4), requiring absolute temperatures in Kelvin.
Wien's Displacement Law dictates peak spectral emission wavelength lambda_max * T = 2897.8 micrometer·K.
Radiative exchange between diffuse-gray surfaces uses view factors F_ij governed by reciprocity (A_i F_ij = A_j F_ji) and summation (sum F_ij = 1) rules.
Inserting N radiation shields of identical emissivity between parallel plates reduces net radiative heat transfer by a factor of 1 / (N + 1).
Industrial heat exchangers are analyzed using the Logarithmic Mean Temperature Difference (LMTD) method (q = U A F DeltaT_lm) when fluid temperatures are known, or Effectiveness-NTU (epsilon-NTU) method when outlet temperatures are unknown.
Last updated: July 2026
5.3 Thermal Radiation & Industrial Heat Exchanger Design
Thermal radiation is the electromagnetic energy emitted by matter as a result of its finite temperature. Unlike conduction and convection, radiation requires no intervening medium and travels at the speed of light in a vacuum ( c 0 ≈ 3 × 10 8 m/s c_0 \approx 3 \times 10^8\text{ m/s} c 0 ≈ 3 × 1 0 8 m/s ).
- 1. Fundamentals of Thermal Radiation & Blackbody Laws
- Blackbody Radiation
A blackbody is an idealized physical body that absorbs all incident electromagnetic radiation, regardless of wavelength or direction, and emits the maximum possible thermal radiation at a given temperature.
Stefan-Boltzmann Law : Total emissive power of a blackbody E b E_b E b is proportional to the fourth power of its absolute temperature: E b = σ T 4 [ W/m 2 ] E_b = \sigma T^4 \quad [\text{W/m}^2] E b = σ T 4 [ W/m 2 ]
Where:
σ = 5.670374 × 10 − 8 W/m 2 ⋅ K 4 \sigma = 5.670374 \times 10^{-8} \text{ W/m}^2\cdot\text{K}^4 σ = 5.670374 × 1 0 − 8 W/m 2 ⋅ K 4 = Stefan-Boltzmann Constant
T T T = Absolute temperature of the surface in Kelvin ( K = ∘ C + 273.15 \text{K} = ^\circ\text{C} + 273.15 K = ∘ C + 273.15 )
Wien's Displacement Law : The wavelength λ m a x \lambda_{max} λ ma x at which blackbody spectral emissive power is maximum is inversely proportional to absolute temperature: λ m a x T = 2897.8 [ μ m ⋅ K ] \lambda_{max} T = 2897.8 \quad [\mu\text{m}\cdot\text{K}] λ ma x T = 2897.8 [ μ m ⋅ K ]
Example: The sun ( T ≈ 5800 K T \approx 5800\text{ K} T ≈ 5800 K ) has peak emission at λ m a x ≈ 0.5 μ m \lambda_{max} \approx 0.5\mu\text{m} λ ma x ≈ 0.5 μ m (visible green-yellow light), while a surface at 300 K 300\text{ K} 300 K peaks at λ m a x ≈ 9.66 μ m \lambda_{max} \approx 9.66\mu\text{m} λ ma x ≈ 9.66 μ m (infrared spectrum).
Real Surface Properties & Kirchhoff's Law
Real surfaces emit and reflect less radiation than a blackbody:
Emissivity ( ϵ \epsilon ϵ ) : ϵ = E ( T ) E b ( T ) ≤ 1.0 \epsilon = \frac{E(T)}{E_b(T)} \le 1.0 ϵ = E b ( T ) E ( T ) ≤ 1.0
Absorptivity ( α \alpha α ) : Fraction of incident radiation absorbed.
Reflectivity ( ρ \rho ρ ) : Fraction reflected.
Transmissivity ( τ \tau τ ) : Fraction transmitted through medium.
For any surface, energy conservation dictates: α + ρ + τ = 1.0 \alpha + \rho + \tau = 1.0 α + ρ + τ = 1.0
For an opaque body ( τ = 0 \tau = 0 τ = 0 ), α + ρ = 1.0 \alpha + \rho = 1.0 α + ρ = 1.0 .
Kirchhoff's Law of Radiation : For any surface in thermal equilibrium with its surroundings, monochromatic directional emissivity equals monochromatic directional absorptivity ( ϵ λ = α λ \epsilon_\lambda = \alpha_\lambda ϵ λ = α λ ). For a diffuse-gray surface , total emissivity equals total absorptivity ( ϵ = α \epsilon = \alpha ϵ = α ).
2. View Factor Algebra & Radiative Heat Exchange
The View Factor (or shape factor) F i j F_{ij} F ij is defined as the fraction of radiation leaving diffuse surface i i i that strikes diffuse surface j j j directly.
Fundamental View Factor Relations
Reciprocity Relation : A i F i j = A j F j i A_i F_{ij} = A_j F_{ji} A i F ij = A j F ji
Summation Rule (for an enclosure of N N N surfaces forming a complete interior space): ∑ j = 1 N F i j = 1.0 for i = 1 , 2 , … , N \sum_{j=1}^{N} F_{ij} = 1.0 \quad \text{for } i = 1, 2, \dots, N j = 1 ∑ N F ij = 1.0 for i = 1 , 2 , … , N
Superposition Rule : If surface j j j is subdivided into parts k k k and l l l ( A j = A k + A l A_j = A_k + A_l A j = A k + A l ): F i ( k + l ) = F i k + F i l F_{i(k+l)} = F_{ik} + F_{il} F i ( k + l ) = F ik + F i l
Flat or Convex Surfaces : Cannot see themselves, so F i i = 0 F_{ii} = 0 F ii = 0 . Concave surfaces have F i i > 0 F_{ii} > 0 F ii > 0 .
Net Radiative Exchange Between Diffuse-Gray Surfaces
Two Infinite Parallel Plates ($
A_1 = A_2 = A$): q 12 ′ ′ = q 12 A = σ ( T 1 4 − T 2 4 ) 1 ϵ 1 + 1 ϵ 2 − 1 q_{12}'' = \frac{q_{12}}{A} = \frac{\sigma (T_1^4 - T_2^4)}{\frac{1}{\epsilon_1} + \frac{1}{\epsilon_2} - 1} q 12 ′′ = A q 12 = ϵ 1 1 + ϵ 2 1 − 1 σ ( T 1 4 − T 2 4 )
Small Object 1 Enclosed by Large Surface 2 ( A 1 ≪ A 2 , F 12 = 1.0 A_1 \ll A_2, F_{12} = 1.0 A 1 ≪ A 2 , F 12 = 1.0 ): q 12 = ϵ 1 A 1 σ ( T 1 4 − T 2 4 ) q_{12} = \epsilon_1 A_1 \sigma (T_1^4 - T_2^4) q 12 = ϵ 1 A 1 σ ( T 1 4 − T 2 4 )
Radiation Shields
Radiation shields are thin, highly reflective sheets placed between radiating surfaces to reduce net radiative heat transfer. Inserting N N N thin shields of identical emissivity ϵ s \epsilon_s ϵ s equal to plate emissivities ( ϵ 1 = ϵ 2 = ϵ s \epsilon_1 = \epsilon_2 = \epsilon_s ϵ 1 = ϵ 2 = ϵ s ) reduces net heat transfer rate to: q s h i e l d e d = 1 N + 1 q u n s h i e l d e d q_{shielded} = \frac{1}{N + 1} q_{unshielded} q s hi e l d e d = N + 1 1 q u n s hi e l d e d
3. Industrial Heat Exchangers & Overall Heat Transfer Coefficient ( U U U )
Heat exchangers are devices that facilitate heat transfer between two fluid streams at different temperatures without mixing them.
Primary Heat Exchanger Configurations
Double-Pipe (Concentric Tube) :
Parallel-Flow : Both hot and cold fluids enter at the same end and flow in the same direction.
Counter-Flow : Hot and cold fluids enter at opposite ends and flow in opposite directions. (Produces higher outlet cold fluid temperature and larger average temperature difference).
Shell-and-Tube : Most common industrial type; contains a bundle of tubes inside a outer shell equipped with baffles (1-shell pass, 2-tube pass; 2-shell pass, 4-tube pass).
Cross-Flow : Fluids flow perpendicular to each other (e.g., automobile radiator); streams can be unmixed or mixed.
Overall Heat Transfer Coefficient ( U U U )
The thermal resistance across a clean tubular heat exchanger wall is: 1 U A = 1 U i A i = 1 U o A o = 1 h i A i + R f , i ′ ′ 1 A i + ln ( r o / r i ) 2 π k L + R f , o ′ ′ 1 A o + 1 h o A o \frac{1}{U A} = \frac{1}{U_i A_i} = \frac{1}{U_o A_o} = \frac{1}{h_i A_i} + R_{f,i}'' \frac{1}{A_i} + \frac{\ln(r_o/r_i)}{2 \pi k L} + R_{f,o}'' \frac{1}{A_o} + \frac{1}{h_o A_o} U A 1 = U i A i 1 = U o A o 1 = h i A i 1 + R f , i ′′ A i 1 + 2 πk L ln ( r o / r i ) + R f , o ′′ A o 1 + h o A o 1
Where R f ′ ′ R_f'' R f ′′ represents fouling factors ( m 2 ⋅ K/W \text{m}^2\cdot\text{K/W} m 2 ⋅ K/W ) resulting from chemical deposits, rust, or biological scaling.
4. Logarithmic Mean Temperature Difference (LMTD) Method
The LMTD method is preferred for heat exchanger sizing when fluid inlet and outlet temperatures are known or specified. q = U A F Δ T l m q = U A F \Delta T_{lm} q = U A F Δ T l m
Where:
Δ T l m \Delta T_{lm} Δ T l m = Logarithmic Mean Temperature Difference for pure counter-flow
F F F = LMTD Correction Factor ( F ≤ 1.0 F \le 1.0 F ≤ 1.0 ; F = 1.0 F = 1.0 F = 1.0 for pure counter-flow or parallel-flow)
Counter-Flow LMTD Equation Δ T l m , C F = Δ T 1 − Δ T 2 ln ( Δ T 1 / Δ T 2 ) \Delta T_{lm,CF} = \frac{\Delta T_1 - \Delta T_2}{\ln(\Delta T_1 / \Delta T_2)} Δ T l m , CF = ln ( Δ T 1 /Δ T 2 ) Δ T 1 − Δ T 2
Where:
- Δ T 1 = T h , i n − T c , o u t \Delta T_1 = T_{h,in} - T_{c,out} Δ T 1 = T h , in − T c , o u t
- Δ T 2 = T h , o u t − T c , i n \Delta T_2 = T_{h,out} - T_{c,in} Δ T 2 = T h , o u t − T c , in
(Note: If Δ T 1 = Δ T 2 \Delta T_1 = \Delta T_2 Δ T 1 = Δ T 2 , then Δ T l m = Δ T 1 \Delta T_{lm} = \Delta T_1 Δ T l m = Δ T 1 .)
Multipass LMTD Correction Factor ( F F F )
For shell-and-tube or cross-flow heat exchangers, F F F is obtained from standard charts using two dimensionless ratios: P = t o u t − t i n T i n − t i n (Thermal Effectiveness Ratio) P = \frac{t_{out} - t_{in}}{T_{in} - t_{in}} \quad \text{(Thermal Effectiveness Ratio)} P = T in − t in t o u t − t in (Thermal Effectiveness Ratio) R = T i n − T o u t t o u t − t i n = m ˙ c c p , c m ˙ h c p , h = C c C h (Heat Capacity Ratio) R = \frac{T_{in} - T_{out}}{t_{out} - t_{in}} = \frac{\dot{m}_c c_{p,c}}{\dot{m}_h c_{p,h}} = \frac{C_c}{C_h} \quad \text{(Heat Capacity Ratio)} R = t o u t − t in T in − T o u t = m ˙ h c p , h m ˙ c c p , c = C h C c (Heat Capacity Ratio)
Where T T T refers to shell-side fluid and t t t refers to tube-side fluid.
5. Effectiveness-NTU ( ϵ \epsilon ϵ -NTU) Method
When fluid outlet temperatures are unknown, the LMTD method requires tedious iteration. The ϵ \epsilon ϵ -NTU Method directly solves performance without iteration.
Definitions
Heat Capacity Rates : C h = m ˙ h c p , h C_h = \dot{m}_h c_{p,h} C h = m ˙ h c p , h and C c = m ˙ c c p , c C_c = \dot{m}_c c_{p,c} C c = m ˙ c c p , c
Minimum Capacity Rate : C m i n = min ( C h , C c ) C_{min} = \min(C_h, C_c) C min = min ( C h , C c )
Capacity Ratio : C r = C m i n C m a x ≤ 1.0 C_r = \frac{C_{min}}{C_{max}} \le 1.0 C r = C ma x C min ≤ 1.0
Maximum Possible Heat Transfer Rate ( q m a x q_{max} q ma x ) : q m a x = C m i n ( T h , i n − T c , i n ) q_{max} = C_{min} (T_{h,in} - T_{c,in}) q ma x = C min ( T h , in − T c , in )
Heat Exchanger Effectiveness ( ϵ \epsilon ϵ ) : ϵ = q a c t u a l q m a x = C h ( T h , i n − T h , o u t ) C m i n ( T h , i n − T c , i n ) = C c ( T c , o u t − T c , i n ) C m i n ( T h , i n − T c , i n ) \epsilon = \frac{q_{actual}}{q_{max}} = \frac{C_h (T_{h,in} - T_{h,out})}{C_{min} (T_{h,in} - T_{c,in})} = \frac{C_c (T_{c,out} - T_{c,in})}{C_{min} (T_{h,in} - T_{c,in})} ϵ = q ma x q a c t u a l = C min ( T h , in − T c , in ) C h ( T h , in − T h , o u t ) = C min ( T h , in − T c , in ) C c ( T c , o u t − T c , in )
- Number of Transfer Units (NTU) : N T U = U A C m i n NTU = \frac{U A}{C_{min}} NT U = C min U A
- Representative ϵ \epsilon ϵ -NTU Formulas
Heat Exchanger Type Effectiveness Equation ϵ = f ( N T U , C r ) \epsilon = f(NTU, C_r) ϵ = f ( NT U , C r )
Double-Pipe Counter-Flow ϵ = 1 − exp [ − N T U ( 1 − C r ) ] 1 − C r exp [ − N T U ( 1 − C r ) ] \epsilon = \frac{1 - \exp[-NTU (1 - C_r)]}{1 - C_r \exp[-NTU (1 - C_r)]} ϵ = 1 − C r e x p [ − NT U ( 1 − C r )] 1 − e x p [ − NT U ( 1 − C r )] (For C r < 1 C_r < 1 C r < 1 )
Double-Pipe Parallel-Flow ϵ = 1 − exp [ − N T U ( 1 + C r ) ] 1 + C r \epsilon = \frac{1 - \exp[-NTU (1 + C_r)]}{1 + C_r} ϵ = 1 + C r 1 − e x p [ − NT U ( 1 + C r )]
Boiler or Condenser ( C r = 0 C_r = 0 C r = 0 ) ϵ = 1 − exp ( − N T U ) \epsilon = 1 - \exp(-NTU) ϵ = 1 − exp ( − NT U )
- 6. Step-by-Step Worked Engineering Calculation (MELE Board Exam Style)
- Problem Statement
A double-pipe counter-flow heat exchanger is used to cool engine lube oil ( c p , h = 2.10 kJ/kg ⋅ K c_{p,h} = 2.10\text{ kJ/kg}\cdot\text{K} c p , h = 2.10 kJ/kg ⋅ K ) from T h , i n = 110 ∘ C T_{h,in} = 110^\circ\text{C} T h , in = 11 0 ∘ C to T h , o u t = 50 ∘ C T_{h,out} = 50^\circ\text{C} T h , o u t = 5 0 ∘ C at a mass flow rate of m ˙ h = 1.5 kg/s \dot{m}_h = 1.5\text{ kg/s} m ˙ h = 1.5 kg/s . Cooling water ( c p , c = 4.18 kJ/kg ⋅ K c_{p,c} = 4.18\text{ kJ/kg}\cdot\text{K} c p , c = 4.18 kJ/kg ⋅ K ) enters the heat exchanger at T c , i n = 20 ∘ C T_{c,in} = 20^\circ\text{C} T c , in = 2 0 ∘ C with a mass flow rate of m ˙ c = 1.2 kg/s \dot{m}_c = 1.2\text{ kg/s} m ˙ c = 1.2 kg/s . The overall heat transfer coefficient is U = 650 W/m 2 ⋅ K U = 650\text{ W/m}^2\cdot\text{K} U = 650 W/m 2 ⋅ K .
Calculate the total heat transfer rate q q q .
Calculate the exit temperature of cooling water T c , o u t T_{c,out} T c , o u t .
Determine the Logarithmic Mean Temperature Difference Δ T l m \Delta T_{lm} Δ T l m .
Calculate the required heat exchanger heat transfer surface area A A A .
- Solution
- Step 1: Calculate Heat Transfer Rate q q q
Calculate oil heat capacity rate C h C_h C h : C h = m ˙ h c p , h = 1.5 kg/s × 2100 J/kg ⋅ K = 3150 W/K C_h = \dot{m}_h c_{p,h} = 1.5\text{ kg/s} \times 2100\text{ J/kg}\cdot\text{K} = 3150\text{ W/K} C h = m ˙ h c p , h = 1.5 kg/s × 2100 J/kg ⋅ K = 3150 W/K
Calculate total heat loss rate from oil q q q : q = C h ( T h , i n − T h , o u t ) = 3150 × ( 110 − 50 ) = 3150 × 60 = 189 , 000 W = 189.0 kW q = C_h (T_{h,in} - T_{h,out}) = 3150 \times (110 - 50) = 3150 \times 60 = 189,000\text{ W} = 189.0\text{ kW} q = C h ( T h , in − T h , o u t ) = 3150 × ( 110 − 50 ) = 3150 × 60 = 189 , 000 W = 189.0 kW
Step 2: Calculate Water Exit Temperature T c , o u t T_{c,out} T c , o u t
Calculate water heat capacity rate C c C_c C c : C c = m ˙ c c p , c = 1.2 kg/s × 4180 J/kg ⋅ K = 5016 W/K C_c = \dot{m}_c c_{p,c} = 1.2\text{ kg/s} \times 4180\text{ J/kg}\cdot\text{K} = 5016\text{ W/K} C c = m ˙ c c p , c = 1.2 kg/s × 4180 J/kg ⋅ K = 5016 W/K
Energy conservation on water side: q = C c ( T c , o u t − T c , i n ) ⟹ 189 , 000 = 5016 × ( T c , o u t − 20 ) q = C_c (T_{c,out} - T_{c,in}) \implies 189,000 = 5016 \times (T_{c,out} - 20) q = C c ( T c , o u t − T c , in ) ⟹ 189 , 000 = 5016 × ( T c , o u t − 20 ) T c , o u t − 20 = 189 , 000 5016 = 37.68 ∘ C ⟹ T c , o u t = 57.68 ∘ C T_{c,out} - 20 = \frac{189,000}{5016} = 37.68^\circ\text{C} \implies T_{c,out} = 57.68^\circ\text{C} T c , o u t − 20 = 5016 189 , 000 = 37.6 8 ∘ C ⟹ T c , o u t = 57.6 8 ∘ C
Step 3: Calculate Logarithmic Mean Temperature Difference (LMTD)
For counter-flow arrangement: Δ T 1 = T h , i n − T c , o u t = 110 − 57.68 = 52.32 ∘ C \Delta T_1 = T_{h,in} - T_{c,out} = 110 - 57.68 = 52.32^\circ\text{C} Δ T 1 = T h , in − T c , o u t = 110 − 57.68 = 52.3 2 ∘ C Δ T 2 = T h , o u t − T c , i n = 50 − 20 = 30.00 ∘ C \Delta T_2 = T_{h,out} - T_{c,in} = 50 - 20 = 30.00^\circ\text{C} Δ T 2 = T h , o u t − T c , in = 50 − 20 = 30.0 0 ∘ C
Calculate Δ T l m \Delta T_{lm} Δ T l m : Δ T l m = Δ T 1 − Δ T 2 ln ( Δ T 1 / Δ T 2 ) = 52.32 − 30.00 ln ( 52.32 / 30.00 ) = 22.32 ln ( 1.7440 ) = 22.32 0.55618 = 40.13 ∘ C \Delta T_{lm} = \frac{\Delta T_1 - \Delta T_2}{\ln(\Delta T_1 / \Delta T_2)} = \frac{52.32 - 30.00}{\ln(52.32 / 30.00)} = \frac{22.32}{\ln(1.7440)} = \frac{22.32}{0.55618} = 40.13^\circ\text{C} Δ T l m = ln ( Δ T 1 /Δ T 2 ) Δ T 1 − Δ T 2 = ln ( 52.32/30.00 ) 52.32 − 30.00 = ln ( 1.7440 ) 22.32 = 0.55618 22.32 = 40.1 3 ∘ C
Step 4: Calculate Required Heat Exchanger Surface Area A A A q = U A Δ T l m ⟹ A = q U Δ T l m q = U A \Delta T_{lm} \implies A = \frac{q}{U \Delta T_{lm}} q = U A Δ T l m ⟹ A = U Δ T l m q A = 189 , 000 W 650 W/m 2 ⋅ K × 40.13 K = 189 , 000 26 , 084.5 = 7.245 m 2 A = \frac{189,000\text{ W}}{650\text{ W/m}^2\cdot\text{K} \times 40.13\text{ K}} = \frac{189,000}{26,084.5} = 7.245\text{ m}^2 A = 650 W/m 2 ⋅ K × 40.13 K 189 , 000 W = 26 , 084.5 189 , 000 = 7.245 m 2
The required surface area for the heat exchanger is 7.25 m 2 7.25\text{ m}^2 7.25 m 2 .