Study guide

12.1 Steam Power Plants & Rankine Cycles

PRC Mechanical Engineer Licensure Examination MELE

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Licensing Overview, Law & Professional Ethics

1.1 MELE Facts, RA 8495 & Board Organization 1.2 Code of Ethics for Mechanical Engineers & Professional Practice 1.3 Philippine Mechanical Engineering Code (PME Code) Governance & Legal Mandates

2 Chapter 2: Advanced Mathematics & Engineering Statistics

2.1 Differential & Integral Calculus in Engineering Applications 2.2 Differential Equations & Mathematical Modeling 2.3 Applied Engineering Statistics & Quality Control Probability

3 Chapter 3: Engineering Thermodynamics

3.1 Thermodynamic State Postulate, Properties & P-V-T Equations of State 3.2 First Law Analysis for Open & Closed Thermal Systems 3.3 Second Law, Entropy, Exergy & Reversibility Analysis

4 Chapter 4: Fluid Mechanics & Hydraulic Engineering

4.1 Fluid Statics, Manometry, Hydrostatic Force & Buoyancy 4.2 Fluid Kinematics, Dynamics & Bernoulli Equation 4.3 Pipe Flow, Friction Losses & Piping Network Analysis

5 Chapter 5: Heat Transfer & Thermal Systems

5.1 Conduction Heat Transfer & Thermal Insulation Design 5.2 Natural & Forced Convection Heat Transfer Correlations 5.3 Thermal Radiation & Industrial Heat Exchanger Design

6 Chapter 6: Mechanics & Strength of Materials

6.1 Statics & Dynamics of Rigid Bodies & Engineering Linkages 6.2 Normal, Shear & Triaxial Stress-Strain Relationships 6.3 Bending Stresses, Torsion & Column Buckling Analysis

7 Chapter 7: Engineering Economics & Financial Analysis

7.1 Time Value of Money & Cash Flow Equivalence Formulas 7.2 Asset Depreciation, Taxation & Economic Evaluation Methods 7.3 Break-Even Analysis, Payback Period & EOQ Inventory Models

8 Chapter 8: Engineering Materials & Metallurgy

8.1 Ferrous & Non-Ferrous Metals, Alloys & Polymers 8.2 Phase Diagrams, Iron-Carbon System & Heat Treatment 8.3 Mechanical Testing, Fatigue Failure & Fracture Mechanics

9 Chapter 9: Machine Elements & Stress Analysis

9.1 Failure Theories, Static & Fluctuating Stress Design 9.2 Power Transmission Shafts, Keys & Rigid/Flexible Couplings 9.3 Spur, Helical, Bevel & Worm Gear Design Calculations

10 Chapter 10: Power Transmission Components

10.1 Belts, V-Belts, Chains, Wire Ropes & Flywheels 10.2 Rolling Element & Hydrodynamic Journal Bearings 10.3 Mechanical Springs, Clutches & Industrial Brakes

11 Chapter 11: Manufacturing, Fasteners & GD&T

11.1 Threaded Fasteners, Rivets & Welded Joint Analysis 11.2 Manufacturing Processes, Machine Tools & Machining Calculations 11.3 Engineering Drawing, Limits, Fits, Tolerances & GD&T

12 Chapter 12: Power Plants, Boilers & Thermal Power Cycles

12.1 Steam Power Plants & Rankine Cycles 12.2 Steam Generators, Boilers & Combustion Engineering 12.3 Internal Combustion Engines: SI & CI Cycles 12.4 Gas Turbine Power Plants & Combined Cycles

13 Chapter 13: Renewable Energy, Fluid Machinery & Plant Systems

13.1 Hydroelectric, Geothermal & Renewable Energy Power Plants 13.2 Pumps & Hydraulic Machinery 13.3 Air Compressors, Fans & Blowers

14 Chapter 14: Refrigeration, HVAC & Building Mechanical Systems

14.1 Refrigeration Systems, Cycles & Refrigerants 14.2 Psychrometrics & Air Conditioning Systems 14.3 Piping/Ductwork Design, PME Code & Industrial Safety Management

12.1 Steam Power Plants & Rankine Cycles

Key Takeaways Explain This Topic AI

The ideal Rankine cycle consists of four internally reversible processes: isentropic compression in the pump, constant-pressure heat addition in the boiler, isentropic expansion in the turbine, and constant-pressure heat rejection in the condenser.

Thermal efficiency η t h = ( w t − w p ) / q i n = ( h 3 − h 4 − ( h 2 − h 1 ) ) / ( h 3 − h 2 ) \eta_{th} = (w_t - w_p) / q_{in} = (h_3 - h_4 - (h_2 - h_1)) / (h_3 - h_2) η t h ​ = ( w t ​ − w p ​ ) / q in ​ = ( h 3 ​ − h 4 ​ − ( h 2 ​ − h 1 ​ )) / ( h 3 ​ − h 2 ​ ) increases with elevated boiler superheat, higher boiler pressure, and lower condenser backpressure.

Reheating increases turbine output quality and efficiency by expanding steam in stages, while Regenerative Feedwater Heating (OFWH/CFWH) improves overall cycle efficiency by reducing boiler heat input requirement.

Supercritical steam power plants operate above the thermodynamic critical point of water ( P c = 22.06 MPa P_c = 22.06\text{ MPa} P c ​ = 22.06 MPa , T c = 373.95 ∘ C T_c = 373.95^\circ\text{C} T c ​ = 373.9 5 ∘ C ), eliminating phase-change boiling and achieving thermal efficiencies above 42-45%.

Heat rate is inversely proportional to thermal efficiency: Heat Rate (kJ/kWh) = 3600 / η t h \text{Heat Rate (kJ/kWh)} = 3600 / \eta_{th} Heat Rate (kJ/kWh) = 3600/ η t h ​ or Heat Rate (Btu/kWh) = 3412 / η t h \text{Heat Rate (Btu/kWh)} = 3412 / \eta_{th} Heat Rate (Btu/kWh) = 3412/ η t h ​ .

Last updated: July 2026

Steam power plants generate the vast majority of central-station base-load electricity worldwide by converting chemical or nuclear thermal energy into mechanical shaft work and electrical energy. The fundamental thermodynamic benchmark for vapor power plants is the Rankine cycle , which resolves the practical engineering operational challenges associated with attempting to compress wet vapor mixtures in the theoretical Carnot vapor cycle.

1. The Simple Ideal Rankine Cycle

The ideal Rankine cycle executes four internally reversible state changes across four main plant components: the condensate/boiler feed pump, steam generator (boiler), steam turbine, and surface condenser.

Component Process Thermodynamic Description Energy Equation (per unit mass)

Pump 1 → \rightarrow → 2 Isentropic Compression w p = h 2 − h 1 = v 1 ( P 2 − P 1 ) w_p = h_2 - h_1 = v_1 (P_2 - P_1) w p ​ = h 2 ​ − h 1 ​ = v 1 ​ ( P 2 ​ − P 1 ​ )

Boiler 2 → \rightarrow → 3 Constant-Pressure Heat Addition q i n = h 3 − h 2 q_{in} = h_3 - h_2 q in ​ = h 3 ​ − h 2 ​

Turbine 3 → \rightarrow → 4 Isentropic Expansion w t = h 3 − h 4 w_t = h_3 - h_4 w t ​ = h 3 ​ − h 4 ​

Condenser 4 → \rightarrow → 1 Constant-Pressure Heat Rejection q o u t = h 4 − h 1 q_{out} = h_4 - h_1 q o u t ​ = h 4 ​ − h 1 ​

State Point Characterization

State 1: Saturated liquid entering the pump at low condenser pressure ( P 1 = P c o n d P_1 = P_{cond} P 1 ​ = P co n d ​ ). Enthalpy h 1 = h f @ P 1 h_1 = h_{f@P1} h 1 ​ = h f @ P 1 ​ , specific volume v 1 = v f @ P 1 v_1 = v_{f@P1} v 1 ​ = v f @ P 1 ​ .

State 2: Compressed liquid exiting the pump and entering the boiler at high operating pressure ( P 2 = P b o i l e r P_2 = P_{boiler} P 2 ​ = P b o i l er ​ ). Since liquid water is virtually incompressible, pump work is calculated via w p ≈ v 1 ( P 2 − P 1 ) w_p \approx v_1 (P_2 - P_1) w p ​ ≈ v 1 ​ ( P 2 ​ − P 1 ​ ) , and h 2 = h 1 + w p h_2 = h_1 + w_p h 2 ​ = h 1 ​ + w p ​ .

State 3: Superheated vapor (or saturated vapor) exiting the boiler drum/superheater at elevated temperature T 3 T_3 T 3 ​ and pressure P 3 P_3 P 3 ​ .

State 4: Wet vapor mixture exiting the steam turbine at condenser pressure ( P 4 = P 1 P_4 = P_1 P 4 ​ = P 1 ​ ). Moisture content is determined by entropy equality s 4 = s 3 = s f @ P 4 + x 4 s f g @ P 4 s_4 = s_3 = s_{f@P4} + x_4 s_{fg@P4} s 4 ​ = s 3 ​ = s f @ P 4 ​ + x 4 ​ s f g @ P 4 ​ , yielding quality x 4 = ( s 3 − s f ) / s f g x_4 = (s_3 - s_f) / s_{fg} x 4 ​ = ( s 3 ​ − s f ​ ) / s f g ​ and enthalpy h 4 = h f + x 4 h f g h_4 = h_f + x_4 h_{fg} h 4 ​ = h f ​ + x 4 ​ h f g ​ .

Thermal Efficiency Formula η t h = w n e t q i n = w t − w p q i n = ( h 3 − h 4 ) − ( h 2 − h 1 ) h 3 − h 2 \eta_{th} = \frac{w_{net}}{q_{in}} = \frac{w_t - w_p}{q_{in}} = \frac{(h_3 - h_4) - (h_2 - h_1)}{h_3 - h_2} η t h ​ = q in ​ w n e t ​ ​ = q in ​ w t ​ − w p ​ ​ = h 3 ​ − h 2 ​ ( h 3 ​ − h 4 ​ ) − ( h 2 ​ − h 1 ​ ) ​

Notice that because pump work w p w_p w p ​ is very small compared to turbine work w t w_t w t ​ (typically < 1 % < 1\% < 1% in subcritical plants), w n e t ≈ w t w_{net} \approx w_t w n e t ​ ≈ w t ​ is often approximated in preliminary calculations, though exact PRC board problems require inclusion of w p w_p w p ​ .

  • 2. Thermodynamic Property Diagrams: T-s and h-s (Mollier)
  • Temperature-Entropy (T-s) Diagram

On the T − s T-s T − s plane, constant pressure lines diverge in the superheated vapor region. Heat input q i n q_{in} q in ​ corresponds to the area under curve 2-3, while heat rejected q o u t q_{out} q o u t ​ is the area under curve 4-1. The enclosed area represents net work output w n e t w_{net} w n e t ​ . Thermal efficiency represents the ratio of the enclosed area to the area under process 2-3.

Enthalpy-Entropy (h-s / Mollier) Diagram

The Mollier diagram plots specific enthalpy h h h against specific entropy s s s . Isentropic turbine expansion (3 → \rightarrow → 4) appears as a vertical straight downward line. Isothermal/isobaric condensation proceeds along sloped constant-pressure lines in the wet mixture region. The vertical length of line 3-4 directly indicates isentropic enthalpy drop and ideal work output w t , i d e a l = h 3 − h 4 w_{t,ideal} = h_3 - h_4 w t , i d e a l ​ = h 3 ​ − h 4 ​ .

3. Rankine Cycle Efficiency Enhancement Strategies

Thermodynamic efficiency increases whenever the average temperature of heat addition T ˉ i n \bar{T}_{in} T ˉ in ​ is raised or the average temperature of heat rejection T ˉ o u t \bar{T}_{out} T ˉ o u t ​ is lowered.

A. Lowering Condenser Backpressure ( P c o n d P_{cond} P co n d ​ )

Lowering condenser operating pressure drops the saturation temperature T c o n d T_{cond} T co n d ​ , which expands the cycle net work area downward. However, P c o n d P_{cond} P co n d ​ is bounded by ambient cooling water temperatures (typically 5 kPa 5\text{ kPa} 5 kPa to 10 kPa 10\text{ kPa} 10 kPa , corresponding to 33 ∘ C 33^\circ\text{C} 3 3 ∘ C – 45 ∘ C 45^\circ\text{C} 4 5 ∘ C ). Excessively low pressure increases moisture content at turbine exhaust ( x 4 < 0.88 x_4 < 0.88 x 4 ​ < 0.88 ), causing severe blade erosion from high-velocity liquid droplet impact.

B. Superheating Steam to Higher Temperatures ( T b o i l e r T_{boiler} T b o i l er ​ )

Superheating raises T ˉ i n \bar{T}_{in} T ˉ in ​ without changing boiler pressure, increasing both cycle thermal efficiency and turbine exhaust steam quality x 4 x_4 x 4 ​ . Modern metallurgical limits cap maximum steam temperatures at approximately 565 ∘ C 565^\circ\text{C} 56 5 ∘ C to 620 ∘ C 620^\circ\text{C} 62 0 ∘ C to prevent superheater tube creep failure.

C. Increasing Boiler Operating Pressure ( P b o i l e r P_{boiler} P b o i l er ​ )

Raising boiler pressure shifts the boiling process to higher temperatures, elevating T ˉ i n \bar{T}_{in} T ˉ in ​ . However, higher pressure narrows the vapor dome, moving turbine expansion deeper into the wet mixture region and decreasing moisture quality x 4 x_4 x 4 ​ below safe operational thresholds unless combined with reheating.

  • 4. Modified Rankine Cycles: Reheat & Regeneration
  • The Reheat Rankine Cycle

To take advantage of high boiler pressures while protecting low-pressure turbine blades from wet steam erosion, steam is expanded in two or more turbine stages:

Steam expands in the High-Pressure (HP) turbine from state 3 to intermediate pressure P r e h e a t P_{reheat} P re h e a t ​ (state 4).

Steam is returned to the boiler reheater section and heated at constant pressure P r e h e a t P_{reheat} P re h e a t ​ back to elevated temperature T 5 ≈ T 3 T_5 \approx T_3 T 5 ​ ≈ T 3 ​ .

Reheated steam expands in the Low-Pressure (LP) turbine to condenser backpressure (state 6). Total Turbine Work w t = ( h 3 − h 4 ) + ( h 5 − h 6 ) \text{Total Turbine Work } w_t = (h_3 - h_4) + (h_5 - h_6) Total Turbine Work w t ​ = ( h 3 ​ − h 4 ​ ) + ( h 5 ​ − h 6 ​ ) Total Heat Input q i n = ( h 3 − h 2 ) + ( h 5 − h 4 ) \text{Total Heat Input } q_{in} = (h_3 - h_2) + (h_5 - h_4) Total Heat Input q in ​ = ( h 3 ​ − h 2 ​ ) + ( h 5 ​ − h 4 ​ ) η t h , r e h e a t = ( h 3 − h 4 ) + ( h 5 − h 6 ) − w p ( h 3 − h 2 ) + ( h 5 − h 4 ) \eta_{th,reheat} = \frac{(h_3 - h_4) + (h_5 - h_6) - w_p}{(h_3 - h_2) + (h_5 - h_4)} η t h , re h e a t ​ = ( h 3 ​ − h 2 ​ ) + ( h 5 ​ − h 4 ​ ) ( h 3 ​ − h 4 ​ ) + ( h 5 ​ − h 6 ​ ) − w p ​ ​

The Regenerative Rankine Cycle & Feedwater Heaters (FWH)

Regenerative heating preheats cold liquid exiting the condensate pump before it enters the boiler by extracting (bleeding) small fractions of expanding steam from turbine stages.

Open Feedwater Heater (OFWH): Direct-contact mixing chamber where bled steam fraction y y y mixes directly with incoming condensate ( 1 − y ) (1-y) ( 1 − y ) . Exiting liquid leaves as saturated liquid at FWH operating pressure.

Closed Feedwater Heater (CFWH): Shell-and-tube heat exchanger where extracted steam condenses on tube surfaces transferring heat to subcooled feedwater flowing inside tubes without direct fluid mixing.

For an Open Feedwater Heater operating at intermediate extraction state h b l e e d h_{bleed} h b l ee d ​ , entering condensate h c o n d , i n h_{cond,in} h co n d , in ​ , and exiting saturated liquid h f w h , o u t h_{fwh,out} h f w h , o u t ​ : y ⋅ h b l e e d + ( 1 − y ) h c o n d , i n = h f w h , o u t ⟹ y = h f w h , o u t − h c o n d , i n h b l e e d − h c o n d , i n y \cdot h_{bleed} + (1 - y) h_{cond,in} = h_{fwh,out} \implies y = \frac{h_{fwh,out} - h_{cond,in}}{h_{bleed} - h_{cond,in}} y ⋅ h b l ee d ​ + ( 1 − y ) h co n d , in ​ = h f w h , o u t ​ ⟹ y = h b l ee d ​ − h co n d , in ​ h f w h , o u t ​ − h co n d , in ​ ​

  • 5. Supercritical Power Plants & Plant Heat Rate
  • Supercritical Steam Power Plants

When boiler operating pressure exceeds the thermodynamic critical pressure of water ( P c = 22.06 MPa P_c = 22.06\text{ MPa} P c ​ = 22.06 MPa or 3200 psia 3200\text{ psia} 3200 psia , T c = 373.95 ∘ C T_c = 373.95^\circ\text{C} T c ​ = 373.9 5 ∘ C ), liquid water transforms continuously into superheated vapor without phase-change boiling. Supercritical (SC) and Ultra-Supercritical (USC) plants operate at pressures from 24.1 MPa 24.1\text{ MPa} 24.1 MPa to 30 + MPa 30+\text{ MPa} 30 + MPa and steam temperatures up to 600 ∘ C 600^\circ\text{C} 60 0 ∘ C – 620 ∘ C 620^\circ\text{C} 62 0 ∘ C , elevating plant thermal efficiency to 42 % 42\% 42% – 48 % 48\% 48% .

Station Heat Rate Metrics

Heat Rate ( H R HR H R ) quantifies the total fuel heat input required in kJ \text{kJ} kJ (or Btu \text{Btu} Btu ) to produce one kilowatt-hour ( kWh \text{kWh} kWh ) of net electrical output. Heat rate is inversely proportional to thermal efficiency: Station Heat Rate (kJ/kWh) = Q ˙ i n ( kW ) W ˙ n e t ( kW ) × 3600 = 3600 η t h \text{Station Heat Rate (kJ/kWh)} = \frac{\dot{Q}_{in} (\text{kW})}{\dot{W}_{net} (\text{kW})} \times 3600 = \frac{3600}{\eta_{th}} Station Heat Rate (kJ/kWh) = W ˙ n e t ​ ( kW ) Q ˙ ​ in ​ ( kW ) ​ × 3600 = η t h ​ 3600 ​ Station Heat Rate (Btu/kWh) = 3412.14 η t h \text{Station Heat Rate (Btu/kWh)} = \frac{3412.14}{\eta_{th}} Station Heat Rate (Btu/kWh) = η t h ​ 3412.14 ​

6. Worked Step-by-Step Steam Power Plant Problem

Problem Statement: A steam power plant operates on an ideal simple Rankine cycle between a boiler pressure of 4.0 MPa 4.0\text{ MPa} 4.0 MPa ( 4000 kPa 4000\text{ kPa} 4000 kPa ) with steam temperature 400 ∘ C 400^\circ\text{C} 40 0 ∘ C , and a condenser pressure of 10 kPa 10\text{ kPa} 10 kPa . Calculate:

  • Specific pump work w p w_p w p ​
  • Enthalpy at turbine exit h 4 h_4 h 4 ​
  • Specific turbine work w t w_t w t ​
  • Cycle thermal efficiency η t h \eta_{th} η t h ​
  • Station heat rate in kJ/kWh \text{kJ/kWh} kJ/kWh
  • Step-by-Step Solution

Step 1: State 1 (Condenser Exit / Pump Inlet) At P 1 = 10 kPa P_1 = 10\text{ kPa} P 1 ​ = 10 kPa (saturated liquid):

h 1 = h f @ 10 k P a = 191.83 kJ/kg h_1 = h_{f@10kPa} = 191.83\text{ kJ/kg} h 1 ​ = h f @10 k P a ​ = 191.83 kJ/kg

v 1 = v f @ 10 k P a = 0.001010 m 3 /kg v_1 = v_{f@10kPa} = 0.001010\text{ m}^3\text{/kg} v 1 ​ = v f @10 k P a ​ = 0.001010 m 3 /kg

s 1 = s f @ 10 k P a = 0.6492 kJ/kg ⋅ K s_1 = s_{f@10kPa} = 0.6492\text{ kJ/kg}\cdot\text{K} s 1 ​ = s f @10 k P a ​ = 0.6492 kJ/kg ⋅ K

s f g @ 10 k P a = 7.5010 kJ/kg ⋅ K s_{fg@10kPa} = 7.5010\text{ kJ/kg}\cdot\text{K} s f g @10 k P a ​ = 7.5010 kJ/kg ⋅ K , h f g @ 10 k P a = 2392.1 kJ/kg h_{fg@10kPa} = 2392.1\text{ kJ/kg} h f g @10 k P a ​ = 2392.1 kJ/kg

Step 2: State 2 (Pump Outlet / Boiler Inlet) w p = v 1 ( P 2 − P 1 ) = 0.001010 m 3 /kg × ( 4000 − 10 ) kPa = 4.03 kJ/kg w_p = v_1 (P_2 - P_1) = 0.001010\text{ m}^3\text{/kg} \times (4000 - 10)\text{ kPa} = 4.03\text{ kJ/kg} w p ​ = v 1 ​ ( P 2 ​ − P 1 ​ ) = 0.001010 m 3 /kg × ( 4000 − 10 ) kPa = 4.03 kJ/kg h 2 = h 1 + w p = 191.83 + 4.03 = 195.86 kJ/kg h_2 = h_1 + w_p = 191.83 + 4.03 = 195.86\text{ kJ/kg} h 2 ​ = h 1 ​ + w p ​ = 191.83 + 4.03 = 195.86 kJ/kg

Step 3: State 3 (Boiler Outlet / Turbine Inlet) From superheated steam tables at P 3 = 4.0 MPa P_3 = 4.0\text{ MPa} P 3 ​ = 4.0 MPa and T 3 = 400 ∘ C T_3 = 400^\circ\text{C} T 3 ​ = 40 0 ∘ C :

  • h 3 = 3213.6 kJ/kg h_3 = 3213.6\text{ kJ/kg} h 3 ​ = 3213.6 kJ/kg
  • s 3 = 6.7690 kJ/kg ⋅ K s_3 = 6.7690\text{ kJ/kg}\cdot\text{K} s 3 ​ = 6.7690 kJ/kg ⋅ K

Step 4: State 4 (Turbine Exit / Condenser Inlet) Isentropic expansion s 4 = s 3 = 6.7690 kJ/kg ⋅ K s_4 = s_3 = 6.7690\text{ kJ/kg}\cdot\text{K} s 4 ​ = s 3 ​ = 6.7690 kJ/kg ⋅ K at P 4 = 10 kPa P_4 = 10\text{ kPa} P 4 ​ = 10 kPa : x 4 = s 4 − s f @ 10 k P a s f g @ 10 k P a = 6.7690 − 0.6492 7.5010 = 6.1198 7.5010 = 0.8158 (81.58% steam quality) x_4 = \frac{s_4 - s_{f@10kPa}}{s_{fg@10kPa}} = \frac{6.7690 - 0.6492}{7.5010} = \frac{6.1198}{7.5010} = 0.8158\text{ (81.58\% steam quality)} x 4 ​ = s f g @10 k P a ​ s 4 ​ − s f @10 k P a ​ ​ = 7.5010 6.7690 − 0.6492 ​ = 7.5010 6.1198 ​ = 0.8158 (81.58% steam quality) h 4 = h f + x 4 h f g = 191.83 + ( 0.8158 × 2392.1 ) = 191.83 + 1951.48 = 2143.31 kJ/kg h_4 = h_f + x_4 h_{fg} = 191.83 + (0.8158 \times 2392.1) = 191.83 + 1951.48 = 2143.31\text{ kJ/kg} h 4 ​ = h f ​ + x 4 ​ h f g ​ = 191.83 + ( 0.8158 × 2392.1 ) = 191.83 + 1951.48 = 2143.31 kJ/kg

Step 5: Turbine Work, Net Work, and Heat Input w t = h 3 − h 4 = 3213.60 − 2143.31 = 1070.29 kJ/kg w_t = h_3 - h_4 = 3213.60 - 2143.31 = 1070.29\text{ kJ/kg} w t ​ = h 3 ​ − h 4 ​ = 3213.60 − 2143.31 = 1070.29 kJ/kg w n e t = w t − w p = 1070.29 − 4.03 = 1066.26 kJ/kg w_{net} = w_t - w_p = 1070.29 - 4.03 = 1066.26\text{ kJ/kg} w n e t ​ = w t ​ − w p ​ = 1070.29 − 4.03 = 1066.26 kJ/kg q i n = h 3 − h 2 = 3213.60 − 195.86 = 3017.74 kJ/kg q_{in} = h_3 - h_2 = 3213.60 - 195.86 = 3017.74\text{ kJ/kg} q in ​ = h 3 ​ − h 2 ​ = 3213.60 − 195.86 = 3017.74 kJ/kg

Step 6: Thermal Efficiency and Heat Rate η t h = w n e t q i n = 1066.26 3017.74 = 0.35334 = 35.33 % \eta_{th} = \frac{w_{net}}{q_{in}} = \frac{1066.26}{3017.74} = 0.35334 = 35.33\% η t h ​ = q in ​ w n e t ​ ​ = 3017.74 1066.26 ​ = 0.35334 = 35.33% Heat Rate = 3600 η t h = 3600 0.35334 = 10 , 188.5 kJ/kWh \text{Heat Rate} = \frac{3600}{\eta_{th}} = \frac{3600}{0.35334} = 10,188.5\text{ kJ/kWh} Heat Rate = η t h ​ 3600 ​ = 0.35334 3600 ​ = 10 , 188.5 kJ/kWh

Loading diagram... Reheat-Regenerative Steam Rankine Cycle Flow Diagram