Study guide
13.3 Air Compressors, Fans & Blowers
PRC Mechanical Engineer Licensure Examination MELE
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Licensing Overview, Law & Professional Ethics
1.1 MELE Facts, RA 8495 & Board Organization 1.2 Code of Ethics for Mechanical Engineers & Professional Practice 1.3 Philippine Mechanical Engineering Code (PME Code) Governance & Legal Mandates
2 Chapter 2: Advanced Mathematics & Engineering Statistics
2.1 Differential & Integral Calculus in Engineering Applications 2.2 Differential Equations & Mathematical Modeling 2.3 Applied Engineering Statistics & Quality Control Probability
3 Chapter 3: Engineering Thermodynamics
3.1 Thermodynamic State Postulate, Properties & P-V-T Equations of State 3.2 First Law Analysis for Open & Closed Thermal Systems 3.3 Second Law, Entropy, Exergy & Reversibility Analysis
4 Chapter 4: Fluid Mechanics & Hydraulic Engineering
4.1 Fluid Statics, Manometry, Hydrostatic Force & Buoyancy 4.2 Fluid Kinematics, Dynamics & Bernoulli Equation 4.3 Pipe Flow, Friction Losses & Piping Network Analysis
5 Chapter 5: Heat Transfer & Thermal Systems
5.1 Conduction Heat Transfer & Thermal Insulation Design 5.2 Natural & Forced Convection Heat Transfer Correlations 5.3 Thermal Radiation & Industrial Heat Exchanger Design
6 Chapter 6: Mechanics & Strength of Materials
6.1 Statics & Dynamics of Rigid Bodies & Engineering Linkages 6.2 Normal, Shear & Triaxial Stress-Strain Relationships 6.3 Bending Stresses, Torsion & Column Buckling Analysis
7 Chapter 7: Engineering Economics & Financial Analysis
7.1 Time Value of Money & Cash Flow Equivalence Formulas 7.2 Asset Depreciation, Taxation & Economic Evaluation Methods 7.3 Break-Even Analysis, Payback Period & EOQ Inventory Models
8 Chapter 8: Engineering Materials & Metallurgy
8.1 Ferrous & Non-Ferrous Metals, Alloys & Polymers 8.2 Phase Diagrams, Iron-Carbon System & Heat Treatment 8.3 Mechanical Testing, Fatigue Failure & Fracture Mechanics
9 Chapter 9: Machine Elements & Stress Analysis
9.1 Failure Theories, Static & Fluctuating Stress Design 9.2 Power Transmission Shafts, Keys & Rigid/Flexible Couplings 9.3 Spur, Helical, Bevel & Worm Gear Design Calculations
10 Chapter 10: Power Transmission Components
10.1 Belts, V-Belts, Chains, Wire Ropes & Flywheels 10.2 Rolling Element & Hydrodynamic Journal Bearings 10.3 Mechanical Springs, Clutches & Industrial Brakes
11 Chapter 11: Manufacturing, Fasteners & GD&T
11.1 Threaded Fasteners, Rivets & Welded Joint Analysis 11.2 Manufacturing Processes, Machine Tools & Machining Calculations 11.3 Engineering Drawing, Limits, Fits, Tolerances & GD&T
12 Chapter 12: Power Plants, Boilers & Thermal Power Cycles
12.1 Steam Power Plants & Rankine Cycles 12.2 Steam Generators, Boilers & Combustion Engineering 12.3 Internal Combustion Engines: SI & CI Cycles 12.4 Gas Turbine Power Plants & Combined Cycles
13 Chapter 13: Renewable Energy, Fluid Machinery & Plant Systems
13.1 Hydroelectric, Geothermal & Renewable Energy Power Plants 13.2 Pumps & Hydraulic Machinery 13.3 Air Compressors, Fans & Blowers
14 Chapter 14: Refrigeration, HVAC & Building Mechanical Systems
14.1 Refrigeration Systems, Cycles & Refrigerants 14.2 Psychrometrics & Air Conditioning Systems 14.3 Piping/Ductwork Design, PME Code & Industrial Safety Management
13.3 Air Compressors, Fans & Blowers
Key Takeaways Explain This Topic AI
Multi-stage compression with perfect intercooling minimizes total compression work when the intermediate pressure stage ratio is uniform, establishing P x = P 1 P 2 P_x = \sqrt{P_1 P_2} P x = P 1 P 2 for a 2-stage unit.
Compression processes follow thermodynamic work profiles where Isothermal work is minimum ( W i s o = P 1 V 1 ln ( P 2 / P 1 ) W_{iso} = P_1 V_1 \ln(P_2/P_1) W i so = P 1 V 1 ln ( P 2 / P 1 ) ), Polytropic work represents real systems, and Isentropic work represents adiabatic conditions.
Clearance volumetric efficiency of reciprocating air compressors ( η v = 1 + c − c ( P 2 / P 1 ) 1 / n \eta_v = 1 + c - c(P_2/P_1)^{1/n} η v = 1 + c − c ( P 2 / P 1 ) 1/ n ) decreases significantly as the pressure ratio increases or clearance ratio c c c expands.
Fans move large gas volumes at low differential pressures (< 3.45 kPa or 14 inches w.g.), categorized into centrifugal (backward-curved, forward-curved, radial) and axial (propeller, tubeaxial, vaneaxial) types.
Fan Air Power (FAP) is calculated as F A P = Q × F T H = Q × ( F S H + V P d ) FAP = Q \times FTH = Q \times (FSH + VP_d) F A P = Q × FT H = Q × ( FS H + V P d ) , obeying fan affinity laws identical to centrifugal pump laws.
Last updated: July 2026
13.3 Air Compressors, Fans & Blowers
Air compressors, fans, and blowers increase gas pressure to deliver pneumatic power or move high volume flows in industrial plant systems. Understanding compressor thermodynamic cycles, intercooling benefits, clearance volumetric efficiency, and fan pressure heads is essential for MELE licensure candidates.
1. Air Compressors
Compressors increase the pressure of gas by reducing its specific volume.
Classification
Positive Displacement Compressors: Reciprocating piston (single and double acting), rotary screw, sliding vane, and scroll compressors.
Dynamic Compressors: Centrifugal (radial) and axial flow compressors.
Thermodynamic Compression Work
For gas compressed from suction state ( P 1 , V 1 , T 1 P_1, V_1, T_1 P 1 , V 1 , T 1 ) to discharge pressure ( P 2 P_2 P 2 ):
Isothermal Compression ( n = 1 n = 1 n = 1 ): Constant temperature process achieved with ideal heat removal. Represents minimum theoretical work: W i s o = P 1 V 1 ln ( P 2 P 1 ) = m R T 1 ln ( P 2 P 1 ) W_{iso} = P_1 V_1 \ln\left(\frac{P_2}{P_1}\right) = m R T_1 \ln\left(\frac{P_2}{P_1}\right) W i so = P 1 V 1 ln ( P 1 P 2 ) = m R T 1 ln ( P 1 P 2 )
Polytropic Compression ( 1 < n < k 1 < n < k 1 < n < k ): Real compression with partial heat transfer: W p o l y = n n − 1 P 1 V 1 [ ( P 2 P 1 ) n − 1 n − 1 ] = n n − 1 m R T 1 [ ( P 2 P 1 ) n − 1 n − 1 ] W_{poly} = \frac{n}{n-1} P_1 V_1 \left[ \left(\frac{P_2}{P_1}\right)^{\frac{n-1}{n}} - 1 \right] = \frac{n}{n-1} m R T_1 \left[ \left(\frac{P_2}{P_1}\right)^{\frac{n-1}{n}} - 1 \right] W p o l y = n − 1 n P 1 V 1 [ ( P 1 P 2 ) n n − 1 − 1 ] = n − 1 n m R T 1 [ ( P 1 P 2 ) n n − 1 − 1 ]
Isentropic (Adiabatic) Compression ( n = k = 1.4 n = k = 1.4 n = k = 1.4 for air): Zero heat transfer during compression: W i s e n = k k − 1 P 1 V 1 [ ( P 2 P 1 ) k − 1 k − 1 ] W_{isen} = \frac{k}{k-1} P_1 V_1 \left[ \left(\frac{P_2}{P_1}\right)^{\frac{k-1}{k}} - 1 \right] W i se n = k − 1 k P 1 V 1 [ ( P 1 P 2 ) k k − 1 − 1 ]
2. Multi-Stage Compression & Intercooling
When compressing air to high overall pressure ratios ( P 2 / P 1 > 4 P_2/P_1 > 4 P 2 / P 1 > 4 ), single-stage compression yields excessively high discharge temperatures (leading to lubricant degradation) and reduced volumetric efficiency.
Intercooling Principles
Air is compressed in a Low Pressure (LP) cylinder, passed through an intercooler heat exchanger to cool back to intake temperature ( T 1 T_1 T 1 ), and then compressed in a High Pressure (HP) cylinder.
Optimum Intermediate Pressure ( P x P_x P x )
For minimum total compression work in a 2-stage compressor with perfect intercooling: P x = P 1 ⋅ P 2 ⟹ P x P 1 = P 2 P x = P 2 P 1 P_x = \sqrt{P_1 \cdot P_2} \quad \implies \quad \frac{P_x}{P_1} = \frac{P_2}{P_x} = \sqrt{\frac{P_2}{P_1}} P x = P 1 ⋅ P 2 ⟹ P 1 P x = P x P 2 = P 1 P 2
Equal pressure ratio per stage: r p , s t a g e = P 2 / P 1 r_{p,stage} = \sqrt{P_2 / P_1} r p , s t a g e = P 2 / P 1 .
Equal work distribution between LP and HP stages ( W L P = W H P W_{LP} = W_{HP} W L P = W H P ).
Total minimum 2-stage polytropic work: W t o t a l , 2 − s t a g e = 2 × n n − 1 P 1 V 1 [ ( P x P 1 ) n − 1 n − 1 ] W_{total, 2-stage} = 2 \times \frac{n}{n-1} P_1 V_1 \left[ \left(\frac{P_x}{P_1}\right)^{\frac{n-1}{n}} - 1 \right] W t o t a l , 2 − s t a g e = 2 × n − 1 n P 1 V 1 [ ( P 1 P x ) n n − 1 − 1 ]
3. Clearance Volumetric Efficiency ( η v \eta_v η v )
In reciprocating compressors, clearance volume ( V c V_c V c ) is necessary to prevent the piston from striking the cylinder head. The clearance ratio is defined as: c = V c V D c = \frac{V_c}{V_D} c = V D V c
Where V D V_D V D is piston displacement (swept volume).
Clearance Volumetric Efficiency Formula
High-pressure air trapped in V c V_c V c re-expands during the suction stroke, delaying fresh air suction intake: η v = 1 + c − c ( P 2 P 1 ) 1 / n \eta_v = 1 + c - c \left(\frac{P_2}{P_1}\right)^{1/n} η v = 1 + c − c ( P 1 P 2 ) 1/ n
Free Air Delivery ( F A D FAD F A D ): Actual volume rate of air delivered, reduced by volumetric efficiency: V a c t u a l = V D ⋅ η v V_{actual} = V_D \cdot \eta_v V a c t u a l = V D ⋅ η v
4. Fans & Blowers
Fans move large gas volumes at low static pressures, whereas blowers operate at intermediate pressure ranges.
Pressure Range Classification
Fans: Differential pressure Δ P ≤ 3.45 kPa \Delta P \le 3.45\text{ kPa} Δ P ≤ 3.45 kPa ( 34.5 mbar 34.5\text{ mbar} 34.5 mbar or 14 in. w.g. 14\text{ in. w.g.} 14 in. w.g. ). Density changes are neglected (incompressible flow assumption).
Blowers: 3.45 kPa < Δ P ≤ 103.4 kPa 3.45\text{ kPa} < \Delta P \le 103.4\text{ kPa} 3.45 kPa < Δ P ≤ 103.4 kPa ( 1 to 30 psig 1\text{ to } 30\text{ psig} 1 to 30 psig ).
Compressors: Δ P > 103.4 kPa \Delta P > 103.4\text{ kPa} Δ P > 103.4 kPa ( > 30 psig > 30\text{ psig} > 30 psig ). Compressibility effects must be considered.
Centrifugal vs. Axial Fans
Centrifugal Fans:
Backward-Curved Vanes (BC): Highest efficiency (up to 85%), self-limiting power characteristic (prevents motor overload at maximum flow rate).
Forward-Curved Vanes (FC): Delivers large air volumes at low rotational speed; power rises steeply with flow rate (risk of motor overloading).
Radial / Straight Vanes: Rugged, self-cleaning blades for industrial dust and particle handling.
Axial Fans: Propeller, tubeaxial, and vaneaxial fans designed for straight-through axial air delivery.
Fan Performance Equations
Velocity Pressure ( V P d VP_d V P d ): V P d = 1 2 ρ a i r V d 2 ⟹ h v = V d 2 2 g VP_d = \frac{1}{2} \rho_{air} V_d^2 \quad \implies \quad h_v = \frac{V_d^2}{2g} V P d = 2 1 ρ ai r V d 2 ⟹ h v = 2 g V d 2
Fan Total Head ( F T H FTH FT H ): F T H = F S H + V P d FTH = FSH + VP_d FT H = FS H + V P d Where F S H FSH FS H is Fan Static Head measured across the fan casing.
Fan Air Power ( F A P FAP F A P ): F A P = Q ⋅ F T H = Q ⋅ ( F S H + V P d ) FAP = Q \cdot FTH = Q \cdot (FSH + VP_d) F A P = Q ⋅ FT H = Q ⋅ ( FS H + V P d ) (In SI units, F A P (kW) = Q (m 3 /s) × F T H (Pa) 1000 FAP\text{ (kW)} = \frac{Q\text{ (m}^3\text{/s)} \times FTH\text{ (Pa)}}{1000} F A P (kW) = 1000 Q (m 3 /s) × FT H (Pa) . In US units, F A P (HP) = Q (cfm) × F T H (in. w.g.) 6356 FAP\text{ (HP)} = \frac{Q\text{ (cfm)} \times FTH\text{ (in. w.g.)}}{6356} F A P (HP) = 6356 Q (cfm) × FT H (in. w.g.) ).
- Fan Brake Power ( F B P FBP FBP ): F B P = F A P η f a n FBP = \frac{FAP}{\eta_{fan}} FBP = η f an F A P
- Fan Affinity Laws
Same relationships as centrifugal pumps: Flow rate Q ∝ N Q \propto N Q ∝ N , Total Head F T H ∝ N 2 FTH \propto N^2 FT H ∝ N 2 , and Power P ∝ N 3 P \propto N^3 P ∝ N 3 .
Worked Air Machinery Calculation
Problem: A two-stage reciprocating air compressor compresses V 1 = 0.15 m 3 / s V_1 = 0.15\text{ m}^3/\text{s} V 1 = 0.15 m 3 / s of free air from suction pressure P 1 = 100 kPa P_1 = 100\text{ kPa} P 1 = 100 kPa and T 1 = 300 K T_1 = 300\text{ K} T 1 = 300 K to a final discharge pressure P 2 = 900 kPa P_2 = 900\text{ kPa} P 2 = 900 kPa . The polytropic expansion/compression index is n = 1.3 n = 1.3 n = 1.3 . Perfect intercooling returns the air to 300 K 300\text{ K} 300 K prior to the second stage. The clearance ratio is c = 0.05 c = 0.05 c = 0.05 (5%). Determine (a) optimum intermediate pressure P x P_x P x , (b) total compressor polytropic power, (c) power saved compared to single-stage compression, and (d) clearance volumetric efficiency of the first stage.
Step-by-Step Solution:
Calculate Optimum Intermediate Pressure ( P x P_x P x ): P x = P 1 ⋅ P 2 = 100 kPa × 900 kPa = 90 , 000 = 300 kPa P_x = \sqrt{P_1 \cdot P_2} = \sqrt{100\text{ kPa} \times 900\text{ kPa}} = \sqrt{90,000} = 300\text{ kPa} P x = P 1 ⋅ P 2 = 100 kPa × 900 kPa = 90 , 000 = 300 kPa
Stage Pressure Ratio: r p , s t a g e = 300 100 = 3.0 r_{p,stage} = \frac{300}{100} = 3.0 r p , s t a g e = 100 300 = 3.0
Calculate Work Per Stage ( W s t a g e W_{stage} W s t a g e ): W s t a g e = n n − 1 P 1 V 1 [ ( P x P 1 ) n − 1 n − 1 ] = 1.3 0.3 × 100 kPa × 0.15 m 3 / s [ ( 3.0 ) 0.3 1.3 − 1 ] W_{stage} = \frac{n}{n-1} P_1 V_1 \left[ \left(\frac{P_x}{P_1}\right)^{\frac{n-1}{n}} - 1 \right] = \frac{1.3}{0.3} \times 100\text{ kPa} \times 0.15\text{ m}^3/\text{s} \left[ (3.0)^{\frac{0.3}{1.3}} - 1 \right] W s t a g e = n − 1 n P 1 V 1 [ ( P 1 P x ) n n − 1 − 1 ] = 0.3 1.3 × 100 kPa × 0.15 m 3 / s [ ( 3.0 ) 1.3 0.3 − 1 ] ( 3.0 ) 0.23077 = 1.2886 (3.0)^{0.23077} = 1.2886 ( 3.0 ) 0.23077 = 1.2886 W s t a g e = 4.3333 × 15 × ( 1.2886 − 1 ) = 65.0 × 0.2886 = 18.759 kW W_{stage} = 4.3333 \times 15 \times (1.2886 - 1) = 65.0 \times 0.2886 = 18.759\text{ kW} W s t a g e = 4.3333 × 15 × ( 1.2886 − 1 ) = 65.0 × 0.2886 = 18.759 kW
Calculate Total Two-Stage Power Output ( W t o t a l W_{total} W t o t a l ): W t o t a l = 2 × W s t a g e = 2 × 18.759 kW = 37.518 kW W_{total} = 2 \times W_{stage} = 2 \times 18.759\text{ kW} = 37.518\text{ kW} W t o t a l = 2 × W s t a g e = 2 × 18.759 kW = 37.518 kW
Calculate Single-Stage Power Requirement ( W s i n g l e W_{single} W s in g l e ): W s i n g l e = 1.3 0.3 × 100 × 0.15 [ ( 900 100 ) 0.3 1.3 − 1 ] = 65.0 × [ ( 9.0 ) 0.23077 − 1 ] W_{single} = \frac{1.3}{0.3} \times 100 \times 0.15 \left[ \left(\frac{900}{100}\right)^{\frac{0.3}{1.3}} - 1 \right] = 65.0 \times \left[ (9.0)^{0.23077} - 1 \right] W s in g l e = 0.3 1.3 × 100 × 0.15 [ ( 100 900 ) 1.3 0.3 − 1 ] = 65.0 × [ ( 9.0 ) 0.23077 − 1 ] ( 9.0 ) 0.23077 = 1.6603 (9.0)^{0.23077} = 1.6603 ( 9.0 ) 0.23077 = 1.6603 W s i n g l e = 65.0 × ( 1.6603 − 1 ) = 65.0 × 0.6603 = 42.920 kW W_{single} = 65.0 \times (1.6603 - 1) = 65.0 \times 0.6603 = 42.920\text{ kW} W s in g l e = 65.0 × ( 1.6603 − 1 ) = 65.0 × 0.6603 = 42.920 kW
Power Saved by 2-Stage Intercooling: Δ P = 42.920 kW − 37.518 kW = 5.402 kW \Delta P = 42.920\text{ kW} - 37.518\text{ kW} = 5.402\text{ kW} Δ P = 42.920 kW − 37.518 kW = 5.402 kW (or a 12.59% energy saving ).
Calculate Clearance Volumetric Efficiency ( η v \eta_v η v ): η v = 1 + c − c ( P x P 1 ) 1 / n = 1 + 0.05 − 0.05 × ( 3.0 ) 1 1.3 \eta_v = 1 + c - c \left(\frac{P_x}{P_1}\right)^{1/n} = 1 + 0.05 - 0.05 \times (3.0)^{\frac{1}{1.3}} η v = 1 + c − c ( P 1 P x ) 1/ n = 1 + 0.05 − 0.05 × ( 3.0 ) 1.3 1 ( 3.0 ) 0.76923 = 2.3276 (3.0)^{0.76923} = 2.3276 ( 3.0 ) 0.76923 = 2.3276 η v = 1.05 − 0.05 × 2.3276 = 1.05 − 0.1164 = 0.9336 = 93.36 % \eta_v = 1.05 - 0.05 \times 2.3276 = 1.05 - 0.1164 = 0.9336 = 93.36\% η v = 1.05 − 0.05 × 2.3276 = 1.05 − 0.1164 = 0.9336 = 93.36%