Study guide
13.1 Hydroelectric, Geothermal & Renewable Energy Power Plants
PRC Mechanical Engineer Licensure Examination MELE
Track your progress as you read
Finished sections get a check mark.
1 Chapter 1: Licensing Overview, Law & Professional Ethics
1.1 MELE Facts, RA 8495 & Board Organization 1.2 Code of Ethics for Mechanical Engineers & Professional Practice 1.3 Philippine Mechanical Engineering Code (PME Code) Governance & Legal Mandates
2 Chapter 2: Advanced Mathematics & Engineering Statistics
2.1 Differential & Integral Calculus in Engineering Applications 2.2 Differential Equations & Mathematical Modeling 2.3 Applied Engineering Statistics & Quality Control Probability
3 Chapter 3: Engineering Thermodynamics
3.1 Thermodynamic State Postulate, Properties & P-V-T Equations of State 3.2 First Law Analysis for Open & Closed Thermal Systems 3.3 Second Law, Entropy, Exergy & Reversibility Analysis
4 Chapter 4: Fluid Mechanics & Hydraulic Engineering
4.1 Fluid Statics, Manometry, Hydrostatic Force & Buoyancy 4.2 Fluid Kinematics, Dynamics & Bernoulli Equation 4.3 Pipe Flow, Friction Losses & Piping Network Analysis
5 Chapter 5: Heat Transfer & Thermal Systems
5.1 Conduction Heat Transfer & Thermal Insulation Design 5.2 Natural & Forced Convection Heat Transfer Correlations 5.3 Thermal Radiation & Industrial Heat Exchanger Design
6 Chapter 6: Mechanics & Strength of Materials
6.1 Statics & Dynamics of Rigid Bodies & Engineering Linkages 6.2 Normal, Shear & Triaxial Stress-Strain Relationships 6.3 Bending Stresses, Torsion & Column Buckling Analysis
7 Chapter 7: Engineering Economics & Financial Analysis
7.1 Time Value of Money & Cash Flow Equivalence Formulas 7.2 Asset Depreciation, Taxation & Economic Evaluation Methods 7.3 Break-Even Analysis, Payback Period & EOQ Inventory Models
8 Chapter 8: Engineering Materials & Metallurgy
8.1 Ferrous & Non-Ferrous Metals, Alloys & Polymers 8.2 Phase Diagrams, Iron-Carbon System & Heat Treatment 8.3 Mechanical Testing, Fatigue Failure & Fracture Mechanics
9 Chapter 9: Machine Elements & Stress Analysis
9.1 Failure Theories, Static & Fluctuating Stress Design 9.2 Power Transmission Shafts, Keys & Rigid/Flexible Couplings 9.3 Spur, Helical, Bevel & Worm Gear Design Calculations
10 Chapter 10: Power Transmission Components
10.1 Belts, V-Belts, Chains, Wire Ropes & Flywheels 10.2 Rolling Element & Hydrodynamic Journal Bearings 10.3 Mechanical Springs, Clutches & Industrial Brakes
11 Chapter 11: Manufacturing, Fasteners & GD&T
11.1 Threaded Fasteners, Rivets & Welded Joint Analysis 11.2 Manufacturing Processes, Machine Tools & Machining Calculations 11.3 Engineering Drawing, Limits, Fits, Tolerances & GD&T
12 Chapter 12: Power Plants, Boilers & Thermal Power Cycles
12.1 Steam Power Plants & Rankine Cycles 12.2 Steam Generators, Boilers & Combustion Engineering 12.3 Internal Combustion Engines: SI & CI Cycles 12.4 Gas Turbine Power Plants & Combined Cycles
13 Chapter 13: Renewable Energy, Fluid Machinery & Plant Systems
13.1 Hydroelectric, Geothermal & Renewable Energy Power Plants 13.2 Pumps & Hydraulic Machinery 13.3 Air Compressors, Fans & Blowers
14 Chapter 14: Refrigeration, HVAC & Building Mechanical Systems
14.1 Refrigeration Systems, Cycles & Refrigerants 14.2 Psychrometrics & Air Conditioning Systems 14.3 Piping/Ductwork Design, PME Code & Industrial Safety Management
13.1 Hydroelectric, Geothermal & Renewable Energy Power Plants
Key Takeaways Explain This Topic AI
Hydroelectric power generation depends directly on the net hydraulic head ( H = H g − h f H = H_g - h_f H = H g − h f ) and volumetric flow rate ( Q Q Q ), with total electrical power calculated as P e = ρ g Q H η o v e r a l l P_e = \rho g Q H \eta_{overall} P e = ρ g Q H η o v er a ll .
Specific speed ( N s = N P / H 5 / 4 N_s = N \sqrt{P} / H^{5/4} N s = N P / H 5/4 ) governs hydro turbine selection: Pelton wheels for high head/low flow, Francis for medium head, and Kaplan/Propeller for low head/high flow.
The Philippines is a global leader in geothermal energy (Tiwi, Leyte, Mak-Ban fields), utilizing Dry Steam, Single-Flash, Double-Flash, and Organic Rankine Cycle (ORC) Binary systems alongside Non-Condensable Gas (NCG) removal and reinjection wells.
Wind energy power output follows P = 0.5 ρ A V 3 C p P = 0.5 \rho A V^3 C_p P = 0.5 ρ A V 3 C p , subject to the theoretical Betz Limit maximum power coefficient of C p ≤ 59.3 % C_p \le 59.3\% C p ≤ 59.3% .
Draft tubes in reaction turbines recover kinetic energy at the runner exit by converting velocity head into static pressure head before discharging into the tailrace.
Last updated: July 2026
13.1 Hydroelectric, Geothermal & Renewable Energy Power Plants
Renewable energy power plants harvest energy from natural, replenishable hydrologic, geothermal, solar, atmospheric, and biological cycles. In the Philippine licensure examination for Mechanical Engineers (MELE), mastery of energy conversion thermodynamics, hydraulic head equations, turbine specific speeds, flash steam thermodynamics, and wind power aerodynamics is critical.
1. Hydroelectric Power Plants
Hydroelectric power conversion converts the gravitational potential energy of elevated water into rotational mechanical energy via hydraulic turbines, which in turn drive electrical generators.
Hydraulic Heads and Energy Losses
Gross Head ( H g H_g H g ): The vertical elevation difference between the headwater surface reservoir level and the tailrace surface water level.
Friction Head Loss ( h f h_f h f ): Hydraulic energy loss per unit weight of fluid due to pipe wall friction and fitting resistance in the penstock, calculated using the Darcy-Weisbach equation: h f = f ⋅ L D ⋅ V 2 2 g h_f = f \cdot \frac{L}{D} \cdot \frac{V^2}{2g} h f = f ⋅ D L ⋅ 2 g V 2
Net Head or Effective Head ( H H H ): The actual head available at the turbine inlet nozzle/entrance: H = H g − h f H = H_g - h_f H = H g − h f
Power Calculations
Water Power (Hydraulic Power Input, P w P_w P w ): P w = γ ⋅ Q ⋅ H = ρ ⋅ g ⋅ Q ⋅ H P_w = \gamma \cdot Q \cdot H = \rho \cdot g \cdot Q \cdot H P w = γ ⋅ Q ⋅ H = ρ ⋅ g ⋅ Q ⋅ H Where ρ = 1000 kg/m 3 \rho = 1000\text{ kg/m}^3 ρ = 1000 kg/m 3 , g = 9.81 m/s 2 g = 9.81\text{ m/s}^2 g = 9.81 m/s 2 , γ = 9.81 kN/m 3 \gamma = 9.81\text{ kN/m}^3 γ = 9.81 kN/m 3 , Q Q Q is volumetric flow rate ( m 3 / s \text{m}^3/\text{s} m 3 / s ), and H H H is net head ( m \text{m} m ).
Turbine Shaft Power Output ( P t P_t P t ): P t = P w ⋅ η h = ρ g Q H η h P_t = P_w \cdot \eta_h = \rho g Q H \eta_h P t = P w ⋅ η h = ρ g Q H η h Where η h \eta_h η h is the hydraulic efficiency of the turbine.
Electrical Generator Power Output ( P e P_e P e ): P e = P w ⋅ η o v e r a l l = ρ g Q H ( η h ⋅ η m ⋅ η g ) P_e = P_w \cdot \eta_{overall} = \rho g Q H (\eta_h \cdot \eta_m \cdot \eta_g) P e = P w ⋅ η o v er a ll = ρ g Q H ( η h ⋅ η m ⋅ η g ) Where η m \eta_m η m is mechanical efficiency and η g \eta_g η g is generator electrical efficiency.
Hydraulic Turbine Classifications
Turbine Class Type Flow Pattern Operating Net Head ( H H H ) Specific Speed ( N s , m e t r i c N_{s,metric} N s , m e t r i c in rpm ⋅ kW 1 / 2 / m 5 / 4 \text{rpm}\cdot\text{kW}^{1/2}/\text{m}^{5/4} rpm ⋅ kW 1/2 / m 5/4 )
Impulse Pelton Wheel Tangential Jet High ( H > 300 m H > 300\text{ m} H > 300 m ) Low ( 10 ≤ N s ≤ 50 10 \le N_s \le 50 10 ≤ N s ≤ 50 )
Reaction Francis Radial-Inward / Mixed Medium ( 30 m ≤ H ≤ 300 m 30\text{ m} \le H \le 300\text{ m} 30 m ≤ H ≤ 300 m ) Medium ( 50 ≤ N s ≤ 300 50 \le N_s \le 300 50 ≤ N s ≤ 300 )
Reaction Kaplan / Propeller Axial Low ( H < 30 m H < 30\text{ m} H < 30 m ) High ( 300 ≤ N s ≤ 1000 300 \le N_s \le 1000 300 ≤ N s ≤ 1000 )
Pelton Wheel: Uses high-velocity free jets impinging on double-hemispherical buckets. Needle valves regulate flow rate without altering jet velocity.
Francis Turbine: A mixed-flow reaction turbine enclosed in a spiral volute casing with adjustable guide vanes (wicket gates) directing water inward onto runner blades.
Kaplan Turbine: An axial-flow propeller turbine featuring automatically adjustable runner blades and guide vanes to maintain high efficiency across partial load operations.
Specific Speed ( N s N_s N s )
Specific speed represents the speed in rpm at which a geometrically similar turbine runner would operate to produce unit power under unit net head: N s = N P H 5 / 4 N_s = \frac{N \sqrt{P}}{H^{5/4}} N s = H 5/4 N P
(Note: In SI/Metric units, N N N is in rpm, P P P is in kW, and H H H is in meters. In US customary units, P P P is in HP and H H H is in feet).
Function of the Draft Tube
The draft tube is a gradually expanding divergent pipe connected between the reaction turbine runner exit and the tailrace. Its functions are:
Allows the turbine to be set above the tailrace level without losing net head.
Recovers a major portion of the kinetic energy ( V 2 2 2 g \frac{V_2^2}{2g} 2 g V 2 2 ) of water exiting the runner by converting it into static pressure head before discharging into the tailrace.
2. Geothermal Power Plants
Geothermal power plants convert hydrothermal energy stored within subterranean magma reservoirs into electricity. The Philippines is one of the world's top producers of geothermal power, with major fields located in Tiwi (Albay) , Leyte , Mak-Ban (Laguna/Batangas) , Tongonan , and Palinpinon .
Geothermal Power Conversion Cycles
Dry Steam Plants: Geothermal wells yield superheated or dry saturated steam ( > 150 ∘ C > 150^\circ\text{C} > 15 0 ∘ C ) containing no liquid water. Steam is piped directly to condensing steam turbines.
Single-Flash Steam Plants: Deep geothermal wells deliver high-pressure liquid-dominated brine. When pressure is reduced in a separator (flash vessel), a fraction flashes into saturated vapor: x = h f l u i d , w e l l − h f , f l a s h h f g , f l a s h x = \frac{h_{fluid,well} - h_{f,flash}}{h_{fg,flash}} x = h f g , f l a s h h f l u i d , w e ll − h f , f l a s h Vapor powers the turbine, while liquid brine is directed to reinjection wells.
Double-Flash Steam Plants: High-pressure liquid discharge from the primary flash separator is flashed a second time at a lower pressure, generating additional low-pressure steam to feed a secondary turbine stage. This increases energy extraction efficiency by 15% to 20% over single-flash designs.
Binary Cycle (Organic Rankine Cycle - ORC): Used for lower temperature reservoirs ( 90 ∘ C ≤ T ≤ 150 ∘ C 90^\circ\text{C} \le T \le 150^\circ\text{C} 9 0 ∘ C ≤ T ≤ 15 0 ∘ C ). Geothermal brine passes through a heat exchanger, evaporating an organic working fluid with a low boiling point (e.g., isobutane, n-pentane, R-134a) operating in a closed Rankine cycle.
Non-Condensable Gas (NCG) Removal and Reinjection
NCG Extraction: Geothermal steam contains 1% to 5% by weight of non-condensable gases ( CO 2 \text{CO}_2 CO 2 , H 2 S \text{H}_2\text{S} H 2 S , NH 3 \text{NH}_3 NH 3 , CH 4 \text{CH}_4 CH 4 ). If allowed to accumulate in the condenser, NCGs raise backpressure, drastically reducing turbine power output. Steam jet ejectors or liquid-ring vacuum pumps continuously purge NCGs from the condenser.
Reinjection Wells: Spent geothermal brine and condensate are pumped back into the periphery of the deep geothermal reservoir to maintain reservoir hydraulic pressure, prevent land subsidence, and avoid surface disposal of toxic dissolved minerals (e.g., arsenic, boron, silica).
- 3. Solar, Wind & Biomass Systems
- Wind Power Aerodynamics & Betz Limit
The theoretical kinetic power available in an atmospheric wind stream crossing swept area A A A at velocity V V V is: P w i n d = 1 2 ⋅ ρ a i r ⋅ A ⋅ V 3 P_{wind} = \frac{1}{2} \cdot \rho_{air} \cdot A \cdot V^3 P w in d = 2 1 ⋅ ρ ai r ⋅ A ⋅ V 3
Where ρ a i r ≈ 1.225 kg/m 3 \rho_{air} \approx 1.225\text{ kg/m}^3 ρ ai r ≈ 1.225 kg/m 3 at standard conditions ( 15 ∘ C , 101.325 kPa 15^\circ\text{C}, 101.325\text{ kPa} 1 5 ∘ C , 101.325 kPa ).
Betz Limit ( C p C_p C p ): According to 1-D momentum theory across an actuator disk, the maximum theoretical power coefficient that a wind turbine can extract from unconstrained wind is: C p , m a x = 16 27 ≈ 59.3 % C_{p,max} = \frac{16}{27} \approx 59.3\% C p , ma x = 27 16 ≈ 59.3%
Actual Extracted Power: P e l e c = 1 2 ρ a i r A V 3 C p ⋅ η m e c h ⋅ η g e n P_{elec} = \frac{1}{2} \rho_{air} A V^3 C_p \cdot \eta_{mech} \cdot \eta_{gen} P e l ec = 2 1 ρ ai r A V 3 C p ⋅ η m ec h ⋅ η g e n
Solar and Biomass Systems
Solar Photovoltaics (PV): Efficiency η = P m a x G ⋅ A p a n e l \eta = \frac{P_{max}}{G \cdot A_{panel}} η = G ⋅ A p an e l P ma x , where G G G is solar irradiance (W/m 2 ^2 2 ). Concentrated Solar Power (CSP) utilizes parabolic troughs or central receiver towers to drive high-temperature Rankine steam cycles.
Biomass Systems: Direct combustion of agricultural residues (bagasse in Philippine sugar mills, coconut shells, wood chips) in boiler furnaces to generate high-pressure steam.
Worked Hydroelectric Plant Calculation
Problem: A hydroelectric plant in Mindanao operates under a gross elevation head of H g = 185 m H_g = 185\text{ m} H g = 185 m with penstock friction head loss h f = 10 m h_f = 10\text{ m} h f = 10 m . The volumetric water flow rate is Q = 15 m 3 / s Q = 15\text{ m}^3/\text{s} Q = 15 m 3 / s . The turbine hydraulic efficiency is η h = 92 % \eta_h = 92\% η h = 92% , mechanical efficiency is η m = 96 % \eta_m = 96\% η m = 96% , and generator efficiency is η g = 97 % \eta_g = 97\% η g = 97% . Determine (a) net head, (b) total electrical power output, and (c) metric specific speed if the turbine rotates at 450 rpm 450\text{ rpm} 450 rpm .
Step-by-Step Solution:
Calculate Net Head ( H H H ): H = H g − h f = 185 m − 10 m = 175 m H = H_g - h_f = 185\text{ m} - 10\text{ m} = 175\text{ m} H = H g − h f = 185 m − 10 m = 175 m
Calculate Water Power Input ( P w P_w P w ): P w = ρ g Q H = 1000 kg/m 3 × 9.81 m/s 2 × 15 m 3 / s × 175 m = 25 , 751 , 250 W = 25.751 MW P_w = \rho g Q H = 1000\text{ kg/m}^3 \times 9.81\text{ m/s}^2 \times 15\text{ m}^3/\text{s} \times 175\text{ m} = 25,751,250\text{ W} = 25.751\text{ MW} P w = ρ g Q H = 1000 kg/m 3 × 9.81 m/s 2 × 15 m 3 / s × 175 m = 25 , 751 , 250 W = 25.751 MW
Calculate Total Combined Efficiency ( η o v e r a l l \eta_{overall} η o v er a ll ): η o v e r a l l = η h × η m × η g = 0.92 × 0.96 × 0.97 = 0.856685 (85.67%) \eta_{overall} = \eta_h \times \eta_m \times \eta_g = 0.92 \times 0.96 \times 0.97 = 0.856685 \text{ (85.67\%)} η o v er a ll = η h × η m × η g = 0.92 × 0.96 × 0.97 = 0.856685 (85.67%)
Calculate Electrical Power Output ( P e P_e P e ): P e = P w × η o v e r a l l = 25.75125 MW × 0.856685 = 22.061 MW P_e = P_w \times \eta_{overall} = 25.75125\text{ MW} \times 0.856685 = 22.061\text{ MW} P e = P w × η o v er a ll = 25.75125 MW × 0.856685 = 22.061 MW
Calculate Turbine Mechanical Shaft Power ( P k W P_{kW} P kW ): P k W = P w × η h = 25751.25 kW × 0.92 = 23 , 691.15 kW P_{kW} = P_w \times \eta_h = 25751.25\text{ kW} \times 0.92 = 23,691.15\text{ kW} P kW = P w × η h = 25751.25 kW × 0.92 = 23 , 691.15 kW
Calculate Metric Specific Speed ( N s N_s N s ): N s = N P k W H 5 / 4 = 450 × 23691.15 ( 175 ) 1.25 = 450 × 153.9193 638.6517 = 108.45 rpm ⋅ kW 1 / 2 / m 5 / 4 N_s = \frac{N \sqrt{P_{kW}}}{H^{5/4}} = \frac{450 \times \sqrt{23691.15}}{(175)^{1.25}} = \frac{450 \times 153.9193}{638.6517} = 108.45\text{ rpm}\cdot\text{kW}^{1/2}/\text{m}^{5/4} N s = H 5/4 N P kW = ( 175 ) 1.25 450 × 23691.15 = 638.6517 450 × 153.9193 = 108.45 rpm ⋅ kW 1/2 / m 5/4
Conclusion: Since N s = 108.45 N_s = 108.45 N s = 108.45 falls within the range 50 ≤ N s ≤ 300 50 \le N_s \le 300 50 ≤ N s ≤ 300 , a Francis reaction turbine is the correct selection.