Study guide

4.3 Sterilization, Disinfection, Decontamination, and Biosafety Containment

Philippine Medical Technologists Licensure Examination MTLE

Track your progress as you read

Finished sections get a check mark.

1 Chapter 1: Clinical Chemistry: Laboratory Operations, Instrumentation, Reagents, Quality Assurance, and Safety

1.1 Specimen Collection, Preanalytical Variables, and Interferences 1.2 Clinical Chemistry Instrumentation, Photometry, and Automation 1.3 Quality Control, Westgard Rules, Calibration, and Laboratory Mathematics 1.4 Reagent Preparation, Laboratory Water, Glassware, Pipettes, and Centrifuges 1.5 Laboratory Safety: Chemical, Fire, Electrical, Biological, and Physical Hazards

2 Chapter 2: Clinical Chemistry: Carbohydrates, Lipids, Proteins, Non-Protein Nitrogen, and Liver Function

2.1 Glucose Homeostasis, Diagnostic Criteria for Diabetes Mellitus, and Glycemic Monitoring 2.2 Lipids, Lipoproteins, Apolipoproteins, and Coronary Heart Disease Risk Assessment 2.3 Serum Proteins, Albumin, Globulins, and Serum Protein Electrophoresis Patterns 2.4 Non-Protein Nitrogen Compounds: Urea, Creatinine, Uric Acid, and Renal Function 2.5 Liver Function Tests, Bilirubin Metabolism, and Jaundice

3 Chapter 3: Clinical Chemistry: Electrolytes, Blood Gases, Enzymology, Endocrinology, and Toxicology

3.1 Water Balance, Electrolytes, Osmolality, and Anion Gap Calculations 3.2 Blood Gas Analysis, Oxygenation, and Acid-Base Homeostasis 3.3 Clinical Enzymology: Enzyme Kinetics, Cardiac Biomarkers, and Hepatic and Pancreatic Enzymes 3.4 Endocrinology: Hormone Physiology and Endocrine Function Testing 3.5 Therapeutic Drug Monitoring and Clinical Toxicology

4 Chapter 4: Bacteriology: Specimen Management, Media, Staining, and Biosafety

4.1 Specimen Collection, Transport, Processing, and Microscopic Staining 4.2 Culture Media Classification, Quality Control, and Inoculation Techniques 4.3 Sterilization, Disinfection, Decontamination, and Biosafety Containment 4.4 Antimicrobial Susceptibility Testing Methods, Standardization, and Resistance Mechanisms

5 Chapter 5: Diagnostic Bacteriology: Major Pathogenic Bacteria

5.1 Medically Important Gram-Positive Cocci: Staphylococci, Streptococci, and Enterococci 5.2 Medically Important Gram-Negative Bacilli: Enterobacterales and Non-Fermenters 5.3 Fastidious, Microaerophilic, and Anaerobic Bacteria 5.4 Mycobacteria, Spirochetes, Atypical Bacteria, and Public Health Microbiology

6 Chapter 6: Medical Parasitology, Mycology, and Diagnostic Virology

6.1 Stool Examination Techniques and Intestinal Nematodes 6.2 Tissue Nematodes, Filarial Worms, Cestodes, and Trematodes 6.3 Medical Protozoology: Intestinal, Urogenital, and Blood/Tissue Protozoa 6.4 Medical Mycology: Yeasts, Dermatophytes, Dimorphic Fungi, and Opportunistic Molds 6.5 Clinical Virology: Viral Structure, Specimen Handling, and Diagnostic Methods

7 Chapter 7: Hematology: Specimen Collection, Routine Parameters, Instrumentation, and Manual Methods

7.1 Blood Specimen Collection, Anticoagulants, Preanalytical Variables, and Specimen Quality 7.2 Automated Cell Counting Principles, Complete Blood Count Parameters, and Erythrocyte Indices 7.3 Reticulocyte Evaluation, Supravital Staining, and Erythrocyte Sedimentation Rate 7.4 Manual Cell Counts, Manual Hemoglobin Methods, and Hematology Quality Control

8 Chapter 8: Hematology: Blood Cell Morphology, Bone Marrow, and Hematologic Disorders

8.1 Normal Erythropoiesis and Erythrocyte Morphologic Abnormalities 8.2 Anemias: Classification, Iron Deficiency, Megaloblastic, Hemolytic, and Hemoglobinopathies 8.3 Normal Leukopoiesis, Leukocyte Differential, and Non-Malignant White Cell Alterations 8.4 Hematologic Malignancies: Acute and Chronic Leukemias, Myeloproliferative and Lymphoproliferative Disorders 8.5 Peripheral Blood Smear Preparation and Staining, Bone Marrow Examination, and Cytochemistry

9 Chapter 9: Hemostasis: Coagulation and Platelet Function Testing and Hemostatic Disorders

9.1 Mechanisms of Primary and Secondary Hemostasis, Fibrinolysis, and Natural Inhibitors 9.2 Coagulation Laboratory Testing: PT/INR, aPTT, Fibrinogen, Thrombin Time, and Mixing Studies 9.3 Hemostatic and Thrombotic Disorders: Hemophilias, von Willebrand Disease, DIC, and Thrombophilias 9.4 Bleeding Time, Clotting Time, Platelet Function, and Special Hematology Tests

10 Chapter 10: Immunohematology: Blood Group Systems and Antiglobulin Testing

10.1 The ABO Blood Group System, Genetics, Subgroups, and Forward/Reverse Typing Discrepancies 10.2 The Rh Blood Group System, Weak D Testing, and Other Major Blood Group Systems 10.3 Antiglobulin Testing, Elution, Adsorption, and Special Antibody Procedures

11 Chapter 11: Blood Banking: Donor Operations, Component Therapy, and Adverse Reactions

11.1 Donor Selection, Physical Examination, Screening, and Mandatory Infectious Marker Testing 11.2 Blood Component Preparation, Storage, Expiration, and Indications for Transfusion 11.3 Pre-Transfusion Compatibility Testing and Transfusion Reactions 11.4 Hemolytic Disease of the Fetus and Newborn (HDFN) and Rh Immune Globulin

12 Chapter 12: Clinical Serology and Immunology

12.1 Principles of Immunology: Antigens, Antibodies, Complement, and Immune Responses 12.2 Serologic Testing Methodologies: Agglutination, Precipitation, Flocculation, and Labeled Immunoassays 12.3 Infectious Disease Serology: Syphilis, Viral Hepatitis Markers, HIV, Dengue, and Febrile Agglutinins 12.4 Autoimmune Serology, Hypersensitivity, Immunodeficiencies, and Histocompatibility (HLA)

13 Chapter 13: Clinical Microscopy: Urinalysis and Renal Pathology

13.1 Renal Physiology, Urine Formation, and Physical Examination of Urine 13.2 Chemical Examination of Urine: Reagent Strip Principles, Interferences, and Confirmatory Tests 13.3 Microscopic Examination of Urine Sediment: Cells, Casts, Crystals, and Contaminants 13.4 Renal Calculi, Glomerular/Tubular/Interstitial Renal Diseases, and Urinalysis Quality Control

14 Chapter 14: Clinical Microscopy: Body Fluids, Fecal Analysis, and Gastric, Duodenal, and Respiratory Specimens

14.1 Cerebrospinal Fluid Analysis: Collection, Cell Counts, Chemistry, and Microbiology 14.2 Serous Fluids (Pleural, Pericardial, Peritoneal: Transudates vs Exudates) and Synovial Fluid Analysis 14.3 Seminal Fluid and Amniotic Fluid Analysis 14.4 Fecal Analysis: Macroscopic, Microscopic, and Chemical Examination of Stool 14.5 Gastric Fluid, Duodenal Contents, Sputum, and Bronchoalveolar Specimens

15 Chapter 15: Histopathologic Techniques and Cytotechnology

15.1 Tissue Preservation, Fixation, Decalcification, and Processing Steps 15.2 Microtomy, Sectioning Artifacts, Hematoxylin and Eosin Staining, and Special Stains 15.3 Cytotechnology: Specimen Collection, Fixation, Papanicolaou Staining, and the Bethesda System 15.4 Special Procedures: Frozen Sections, Special Embedding, Immunohistochemistry, Electron Microscopy, Autopsy, Museum Techniques, and Laboratory Records

16 Chapter 16: Medical Technology Laws, Related Laws, and Ethics

16.1 Republic Act No. 5527 (The Philippine Medical Technology Act of 1969) and Key Amendments 16.2 Related Philippine Healthcare Laws, Code of Ethics, and Bioethics

4.3 Sterilization, Disinfection, Decontamination, and Biosafety Containment

Key Takeaways Explain This Topic AI

Steam autoclaving achieves sterilization at 121 ∘ C 121^\circ\text{C} 12 1 ∘ C and 15 psi 15\text{ psi} 15 psi for 15 minutes, with cycle efficacy verified biologically using Geobacillus stearothermophilus endospores.

Dry heat sterilization requires 160 – 170 ∘ C 160\text{--}170^\circ\text{C} 160 – 17 0 ∘ C for 1.5 to 2 hours with Bacillus atrophaeus spore monitoring, whereas heat-labile liquids must be sterilized using 0.22 μ m 0.22\ \mu\text{m} 0.22 μ m membrane filtration.

Biosafety Level 3 (BSL-3) containment is mandatory for aerosol-transmitted pathogens causing potentially lethal disease (Mycobacterium tuberculosis, Brucella), requiring directional inward negative airflow and Class II/III biosafety cabinets.

The Philippine DOH Health Care Waste Management Manual (4th edition, 2020) assigns yellow to infectious, pathological, and anatomical waste and to labelled puncture-proof sharps containers, brown to chemical and pharmaceutical waste, orange to radioactive waste, and black or green to general waste.

Last updated: October 2026

Sterilization, Disinfection, Decontamination, and Biosafety Containment

Medical microbiology laboratories routinely manipulate viable, high-titer bacterial, fungal, and viral pathogens. Preventing accidental laboratory-acquired infections (LAIs), cross-contamination of diagnostic cultures, and environmental pathogen release requires absolute mastery of physical and chemical decontamination, biological indicators, engineering controls (Biosafety Cabinets), containment facility design (Biosafety Levels 1 through 4), and national regulatory waste segregation frameworks. These concepts represent high-yield core competencies on the Philippine MTLE and international board examinations.

1. Physical Methods of Sterilization

Sterilization is the complete destruction or irreversible elimination of all viable microorganisms, including vegetative bacterial cells, mycobacteria, fungi, viruses, and highly resistant bacterial endospores.

Moist Heat under Pressure (Autoclaving)

Steam under pressure is the most efficient, cost-effective, and dependable sterilization modality in clinical and industrial microbiology:

Mechanism of Microbial Inactivation : Saturated steam possesses immense latent heat. When steam contacts cooler objects, it condenses, rapidly releasing thermal energy that induces irreversible coagulation and denaturation of essential structural proteins and metabolic enzymes .

Standard Operating Parameters : The standard autoclaving cycle for culture media, surgical instruments, and biohazardous waste decontamination operates at 121 ∘ C 121^\circ\text{C} 12 1 ∘ C ( 250 ∘ F 250^\circ\text{F} 25 0 ∘ F ) under 15 pounds per square inch (psi) 15\text{ pounds per square inch (psi)} 15 pounds per square inch (psi) ( 103.4 kPa 103.4\text{ kPa} 103.4 kPa ) of gauge pressure for 15 minutes (for volumes ≤ 1 liter \le 1\text{ liter} ≤ 1 liter ; large volume liquid loads require 20 to 30 minutes). Prevacuum high-temperature autoclaves operate at 132 ∘ C 132^\circ\text{C} 13 2 ∘ C at 30 psi 30\text{ psi} 30 psi for 3 to 4 minutes.

Air Displacement and Bowie-Dick Test : Trapped air acts as an insulator, preventing steam from contacting surfaces and reducing the chamber temperature. In prevacuum sterilizers, vacuum pumps evacuate air prior to steam injection. The Bowie-Dick test (a standardized chemical indicator sheet placed inside a towel pack) evaluates daily dynamic air removal; a uniform color change across the sheet verifies that air was completely purged.

Biological Indicator (Gold Standard) : Autoclave sterilization cycles must be monitored biologically using endospores of G e o b a c i l l u s s t e a r o t h e r m o p h i l u s Geobacillus\ stearothermophilus G eo ba c i ll u s s t e a ro t h er m o p hi l u s (formerly Bacillus stearothermophilus , ATCC 7953). Spores are contained in flexible vials with nutrient broth and bromocresol purple pH indicator. Following the autoclave run, the vial is crushed to immerse spores in broth and incubated at 55 to 60 ∘ C 55\text{ to }60^\circ\text{C} 55 to 6 0 ∘ C . If the cycle was successful, the spores are dead and the broth remains purple . If the cycle failed, surviving spores germinate and ferment carbohydrates to acid, turning the broth yellow .

Dry Heat Sterilization

Mechanism : Inactivates microbes through destructive oxidation of cellular constituents , cellular dehydration, and thermal protein denaturation.

Operating Parameters : Dry heat requires significantly higher temperatures and longer exposure times than moist heat because dry air transfers thermal energy slowly. Standard hot-air oven parameters are 160 to 170 ∘ C 160\text{ to }170^\circ\text{C} 160 to 17 0 ∘ C for 1.5 to 2 hours 1.5\text{ to }2\text{ hours} 1.5 to 2 hours , or 170 ∘ C 170^\circ\text{C} 17 0 ∘ C for 1 hour 1\text{ hour} 1 hour .

Applications : Sterilizing moisture-sensitive anhydrous items that steam cannot penetrate or would destroy: mineral oils, petroleum jelly, paraffin waxes, talcum powders, and heat-resistant laboratory glassware (pipettes, glass petri dishes).

Biological Indicator : Endospores of B a c i l l u s a t r o p h a e u s Bacillus\ atrophaeus B a c i ll u s a t ro p ha e u s (formerly Bacillus subtilis var. niger , ATCC 9372), incubated at 35 to 37 ∘ C 35\text{ to }37^\circ\text{C} 35 to 3 7 ∘ C .

Membrane Filtration

Mechanism : Physical sieving and exclusion of microbes by passing liquids through polymeric membranes (cellulose acetate, polyethersulfone, polycarbonate) with a calibrated pore diameter of 0.22 μ m 0.22\ \mu\text{m} 0.22 μ m (or 0.45 μ m 0.45\ \mu\text{m} 0.45 μ m ).

Applications : Sterilization of heat-labile pharmaceutical and bacteriological media supplements: animal sera (fetal bovine serum), carbohydrate fermentation solutions, urea solutions, antibiotic supplements, and enzyme solutions.

Diagnostic Limitation : Membrane filters with a 0.22 μ m 0.22\ \mu\text{m} 0.22 μ m pore size retain vegetative bacteria, fungi, and bacterial endospores, but do not retain viruses, prions, or wall-less Mycoplasma species .

Ionizing Radiation

Mechanism : High-energy gamma rays (emitted by Cobalt-60, 60 Co ^{60}\text{Co} 60 Co ) and electron beam accelerators induce direct double-strand DNA cleavage and generate highly reactive hydroxyl free radicals ( O H ∙ OH^\bullet O H ∙ ) from cellular water, destroying nucleic acids.

Applications : Industrial "cold sterilization" of pre-packaged, heat-sensitive single-use disposable plastic laboratory supplies: plastic petri dishes, vacutainer tubes, plastic serological pipettes, syringes, and surgical catheters.

2. Chemical Sterilization, High-Level Disinfection, and Antiseptics ┌──────────────────────────────────────────────┐

  • │ Microbial Inactivation Classification │
  • └──────────────────────┬───────────────────────┘
  • │
  • ┌───────────────────────────────────────┼──────────────────────────────────────┐
  • ▼ ▼ ▼
  • ┌──────────────┐ ┌──────────────┐ ┌──────────────┐
  • │Sterilization │ │ High-Level │ │ Intermediate/│
  • │ (Absolute) │ │ Disinfection │ │ Low-Level │
  • └──────┬───────┘ └──────┬───────┘ └──────┬───────┘
  • │ │ │
  • Destroys ALL life, Destroys ALL vegetative Destroys most vegetative
  • including bacterial bacteria, mycobacteria, bacteria, enveloped
  • endospores fungi, and viruses viruses, some fungi;
  • Autoclave (121°C/15 psi) (Spore count reduced) INACTIVE on spores
  • Dry Heat (170°C/1 hr) • 2% Glutaraldehyde • 70% Alcohols (Ethanol,
  • Ethylene Oxide gas (20-30 min immersion) Isopropanol)
  • 2% Glutaraldehyde • 1:10 Bleach • Quats (Benzalkonium)
  • (10 hr continuous) (10-20 min contact) • Phenolics (Cresol)

Ethylene Oxide (EtO) Gas :

Mechanism : Alkylating agent that replaces labile hydrogen atoms on sulfhydryl ( − S H -SH − S H ), amino ( − N H 2 -NH_2 − N H 2 ​ ), hydroxyl ( − O H -OH − O H ), and carboxyl ( − C O O H -COOH − COO H ) groups with hydroxyethyl radicals, cross-linking and inactivating proteins and nucleic acids.

Parameters : Gas concentration 450 – 1 , 200 mg/L 450\text{--}1,200\text{ mg/L} 450 – 1 , 200 mg/L , temperature 29 – 65 ∘ C 29\text{--}65^\circ\text{C} 29 – 6 5 ∘ C , relative humidity 40 % – 80 % 40\%\text{--}80\% 40% – 80% , exposure time 2 – 5 hours 2\text{--}5\text{ hours} 2 – 5 hours , followed by 8 to 12 hours 8\text{ to }12\text{ hours} 8 to 12 hours of mechanical aeration at 50 – 60 ∘ C 50\text{--}60^\circ\text{C} 50 – 6 0 ∘ C to desorb toxic, carcinogenic, and explosive EtO residues.

Biological Indicator : Bacillus atrophaeus spores.

Glutaraldehyde (2% Activated Alkaline Solution) :

Mechanism : Dialdehyde that alkylates sulfhydryl, amino, and hydroxyl groups of proteins and nucleic acids.

Spectrum and Exposure : Activated with sodium bicarbonate to pH 7.5 – 8.5 \text{pH } 7.5\text{--}8.5 pH 7.5 – 8.5 . Functions as a High-Level Disinfectant (HLD) with an immersion contact time of 20 to 30 minutes 20\text{ to }30\text{ minutes} 20 to 30 minutes at 20 ∘ C 20^\circ\text{C} 2 0 ∘ C (kills vegetative bacteria, Mycobacterium tuberculosis , fungi, and lipid/non-lipid viruses). Functions as a chemical sterilant only upon continuous immersion for 10 hours (kills resistant bacterial endospores). Used for heat-labile immersible equipment (bronchoscopes, endoscopes).

Sodium Hypochlorite (Household Bleach) :

Mechanism : Forms undissociated hypochlorous acid ( H O C l HOCl H OCl ), a potent oxidizing agent that oxidizes sulfhydryl bonds in vital metabolic enzymes and disrupts membrane integrity.

Dilution and Contact : Standard household bleach ( 5.25 % to 6.15 % 5.25\%\text{ to }6.15\% 5.25% to 6.15% sodium hypochlorite) is diluted 1:10 with water to yield approximately 5 , 000 parts per million (ppm) 5,000\text{ parts per million (ppm)} 5 , 000 parts per million (ppm) ( 0.525 % 0.525\% 0.525% ) of available chlorine . A 1:10 dilution prepared fresh daily is the standard disinfectant for cleaning blood spills, biological fluids, and infectious bench surfaces, requiring a minimum of 10 to 20 minutes 10\text{ to }20\text{ minutes} 10 to 20 minutes of wet contact time . Hypochlorite decomposes rapidly upon standing and is corrosive to stainless steel.

Alcohols (70% Ethyl and Isopropyl Alcohol) :

Mechanism : Rapidly denatures microbial proteins and dissolves membrane lipid bilayers.

Why 70% is Optimal : Absolute ( 100 % 100\% 100% ) alcohol is ineffective because it instantly coagulates surface envelope proteins, forming a protective impermeable shell that prevents the alcohol from penetrating the cytoplasm. Water is strictly required to slow evaporation, hydrate cellular structures, and facilitate trans-membrane diffusion. Ineffective against bacterial endospores and non-enveloped hydrophilic viruses (poliovirus, hepatitis A).

Quaternary Ammonium Compounds ("Quats") : Cationic surfactants (e.g., benzalkonium chloride) that disrupt microbial cytoplasmic membranes. Low-level disinfectants used for non-critical environmental surfaces (floors, walls); inactivated by organic debris, hard water, and anionic soaps.

3. Biosafety Containment Levels (BSL-1 through BSL-4)

The Centers for Disease Control and Prevention (CDC) and World Health Organization (WHO) define four Biosafety Levels (BSL) combining laboratory practices, safety equipment, and facility design:

Biosafety Level Pathogen Characteristics / Risk Profile Facility Containment & Engineering Controls Representative Microorganisms

BSL-1 Well-characterized agents of minimal hazard not known to consistently cause disease in healthy immunocompetent adult humans Standard open-bench microbiology; sink for handwashing; decontamination of surfaces; personal protective equipment (PPE: lab coat, gloves) Escherichia coli K12, Bacillus subtilis , Lactobacillus acidophilus

BSL-2 Moderate individual risk; agents associated with human disease transmitted via percutaneous injury, ingestion, or mucous membrane exposure Restricted laboratory access; biohazard warning signs; autoclave available; all procedures generating infectious aerosols/splashes conducted in Biosafety Cabinet (BSC) Staphylococcus aureus , Salmonella enterica , Hepatitis B Virus (HBV), HIV, Cryptococcus neoformans

BSL-3 Indigenous or exotic agents with high potential for aerosol transmission causing serious or potentially lethal systemic disease Controlled access via double-door entry; directional inward negative airflow (room air exhausted through HEPA filters without recirculation); sealed penetrations; all work in Class II/III BSCs; respiratory protection (PAPR or fit-tested N95) Mycobacterium tuberculosis , Brucella abortus , Francisella tularensis , Bacillus anthracis , Coccidioides immitis , SARS-CoV-2

BSL-4 High individual and community risk; dangerous, exotic agents posing extreme risk of aerosol-transmitted life-threatening disease with no available vaccine or therapy Maximum containment; completely isolated facility; positive-pressure air-supplied full-body suits OR Class III gastight BSC glovebox line; double-door airlock entries; chemical decontamination shower; dedicated air and waste treatment systems Filoviruses ( Ebola , Marburg ), Arenaviruses ( Lassa ), Nairoviruses ( Crimean-Congo hemorrhagic fever ), Variola (Smallpox)

4. Biosafety Cabinets (BSC Classes and Types)

Biosafety cabinets provide primary engineering containment through laminar airflow and High-Efficiency Particulate Air (HEPA) filters ( 99.97 % 99.97\% 99.97% efficient at trapping particles ≥ 0.3 μ m \ge 0.3\ \mu\text{m} ≥ 0.3 μ m in diameter): ┌────────────────────────────────────────────────────────┐

  • │ Biosafety Cabinet Configurations │
  • └───────────────────────────┬────────────────────────────┘
  • │
  • ┌──────────────────────────────────┼──────────────────────────────────┐
  • ▼ ▼ ▼
  • ┌──────────────┐ ┌──────────────┐ ┌──────────────┐
  • │ Class I │ │ Class II │ │ Class III │
  • │(Negative Pr.)│ │(Laminar Flow)│ │ (Glovebox) │
  • └──────┬───────┘ └──────┬───────┘ └──────┬───────┘
  • │ │ │
  • Operator: YES • Operator: YES • Operator: MAXIMUM
  • Environment: YES • Environment: YES • Environment: MAXIMUM
  • Product (Media): NO • Product (Media): YES • Product: MAXIMUM
  • (Inward air passes (Vertical downflow HEPA (Gastight, sealed ports,
  • directly over culture) bathes work surface) double HEPA exhaust)

Class I BSC : Inward air face velocity of 75 – 100 linear feet per minute (lfpm) 75\text{--}100\text{ linear feet per minute (lfpm)} 75 – 100 linear feet per minute (lfpm) . Unfiltered room air is drawn through the front opening directly across the work surface and exhausted through a HEPA filter. Protects personnel and the environment, but provides NO product protection (room air contaminants sweep across the culture plate).

Class II BSC (Laminar Flow Cabinets) : Protects personnel, environment, AND product/cultures . Employs a vertical laminar downflow of HEPA-filtered clean air that bathes the work surface:

Type A1 : Face velocity 75 lfpm 75\text{ lfpm} 75 lfpm ; recirculates 70 % 70\% 70% of air through supply HEPA filter, exhausts 30 % 30\% 30% through exhaust HEPA back into room. Contaminated plenums under positive pressure.

Type A2 : Face velocity 100 lfpm 100\text{ lfpm} 100 lfpm ; recirculates 70 % 70\% 70% , exhausts 30 % 30\% 30% to room or via canopy thimble exhaust duct to outdoors. All biologically contaminated ducts are under negative pressure or surrounded by negative pressure plenums.

Type B1 : Face velocity 100 lfpm 100\text{ lfpm} 100 lfpm ; recirculates 30 % 30\% 30% , exhausts 70 % 70\% 70% through dedicated hard ductwork outdoors. Suitable for work with minute amounts of volatile chemicals.

Type B2 (Total Exhaust) : 0 % 0\% 0% recirculation, 100 % 100\% 100% total exhaust through dedicated hard building ductwork directly outdoors after HEPA filtration. Mandatory when manipulating volatile toxic chemicals, radionuclides, or chemical carcinogens alongside microbiological pathogens.

Class III BSC (Gastight Glovebox) : Totally enclosed, hermetically sealed, gastight containment box operated under negative pressure ( ≥ 0.5 inches water gauge \ge 0.5\text{ inches water gauge} ≥ 0.5 inches water gauge ). Manipulations are performed through heavy butyl rubber gloves attached to glove ports. Air is double-HEPA filtered. Materials enter through a double-door pass-through autoclave or chemical dunk tank. Provides the maximum possible protection for BSL-4 agents.

5. Healthcare Waste Management (Philippine DOH Standards)

Under the Philippine Department of Health (DOH) Health Care Waste Management Manual (4th edition, 2020) and Republic Act 6969 (Toxic Substances and Hazardous and Nuclear Wastes Control Act), clinical laboratories must segregate waste at the point of generation into color-coded bins with matching plastic liners (recommended liner thickness 0.07 mm 0.07\text{ mm} 0.07 mm ):

Waste Category Bin / Liner Color Container Specifications Approved Contents and Disposal Requirements

Infectious, Pathological & Anatomical Waste Yellow Strong, leak-proof bin with cover; autoclavable liner; biohazard symbol Inoculated culture plates, swabs, blood bags, specimen tubes, human tissues, biopsies, contaminated PPE. Treated (for example, autoclaved) before final disposal.

Sharps Waste Yellow puncture-proof container labelled "Sharps" Puncture-proof container with wide mouth and cover; biohazard symbol Needles, scalpels, lancets, broken glass slides, broken culture tubes. Collected when three-quarters full , then sealed and treated.

Pharmaceutical & Chemical Waste Brown Strong, leak-proof bin; material resistant to the chemical Expired reagents, formalin, xylene, stains, expired drugs, cytotoxic and genotoxic waste.

Radioactive Waste Orange liner in a lead-lined, leak-proof repository Labelled with the radionuclide and date of deposition Residues from radioimmunoassay or nuclear medicine work.

Non-Biodegradable General Waste Black (colorless liners allowed) Standard lidded bin Clean packaging, paper, uncontaminated plastic wrap.

Biodegradable General Waste Green Standard lidded bin Food scraps and other compostable refuse.

Note

Older editions of the manual (and many review books) used red for sharps and yellow with a black band for chemical waste. Questions on the current scheme follow the 2020 edition above.