Study guide
25.3 General Pharmacologic Principles: Pharmacokinetics, Pharmacodynamics, Drug Categories & the Rights of Drug Safety
Philippine Radiologic Technologists Licensure Examination Exam
Track your progress as you read
Finished sections get a check mark.
1 Subject 1, Chapter 1: Physics of Radiology & X-Ray Production
1.1 Atomic Structure, Electromagnetic Spectrum & X-Ray Production Mechanisms 1.2 X-Ray Tube Components, Target Interactions & Emission Spectrum 1.3 Photon Interactions with Matter: Photoelectric, Compton, Coherent & Pair Production
2 Subject 1, Chapter 2: Radiographic Equipment & Circuitry
2.1 High-Voltage Generators, Transformers & Rectification Circuits 2.2 Automatic Exposure Control (AEC), Beam Restriction & Quality Control 2.3 Tube Rating Charts, Extending Tube Life, Mechanical Malfunction & Preventive Maintenance
3 Subject 1, Chapter 3: Radiobiology & Cellular Response
3.1 Radiation Interaction with Tissue, Direct/Indirect Action & LET/RBE 3.2 Law of Bergonie & Tribondeau, Deterministic vs. Stochastic Effects 3.3 Dose-Response Relationships, Embryo and Fetal Effects & Acute Radiation Syndrome
4 Subject 1, Chapter 4: Radiation Protection & Dose Limits
4.1 ALARA Principles, Structural Shielding & Dose Limits 4.2 Personnel Dosimetry & Patient Dose Reduction Techniques 4.3 Dose Calculation Problems: Time, Distance, Shielding & Structural Barrier Design
5 Subject 1, Chapter 5: Imaging Informatics & Quality Assurance
5.1 PACS Architecture, DICOM Standards & HL7 Integration 5.2 Quality Assurance & Quality Control Protocols in Diagnostic Radiography 5.3 Radiology Workflow, RIS/HIS Integration, Teleradiology & Informatics Quality Assurance
6 Subject 2, Chapter 6: Film-Screen Radiography & Sensitometry
6.1 Film Emulsion, Latent Image Formation & Darkroom Chemistry 6.2 Sensitometric Curve (H&D Curve), Film Speed & Contrast Characteristics 6.3 Radiographic Film Analysis: Processing Faults, Handling Artifacts & Corrective Measures
7 Subject 2, Chapter 7: Technical Factors & Radiographic Quality
7.1 Density/Brightness, Contrast, Spatial Resolution & Distortion Controls 7.2 Exposure Math: Inverse Square Law, 15% Rule & Grid Conversion Factors 7.3 Technique Compensation: Age, Pathology, Cast and Orthopaedic Devices, Screen Speed & Beam Restriction
8 Subject 2, Chapter 8: Computed Radiography (CR)
8.1 Photostimulable Phosphor (PSP) Plates & CR Reader Mechanics 8.2 Image Processing, CR Artifacts & Erasure Protocols
9 Subject 2, Chapter 9: Digital Radiography (DR)
9.1 Flat-Panel Detectors: Direct vs. Indirect Conversion & TFT Arrays 9.2 Detective Quantum Efficiency (DQE), Modulation Transfer Function (MTF) & Dynamic Range
10 Subject 2, Chapter 10: Exposure Indicators & Image Evaluation
10.1 Exposure Indicators (S-Number, EI, DI), Windowing & Look-Up Tables (LUT) 10.2 Image Critique Checklist, Artifact Identification & Quality Control Standards 10.3 Image Display & Hard-Copy Output: Monitor Classification, DICOM GSDF, Dry vs Wet Laser Imaging
11 Subject 3, Chapter 11: Chest, Abdomen & Routine Positioning Concepts
11.1 Anatomical Terminology, Body Planes & Chest Radiography (PA, Lateral, Decubitus) 11.2 Abdominal Radiography: Acute Abdomen Series & Erect/Supine Protocols 11.3 Radiologic Surface Anatomy, Body Habitus & Sectional Body Cuts
12 Subject 3, Chapter 12: Upper & Lower Extremities & Girdles
12.1 Upper Limb & Shoulder Girdle Positioning (Hand, Wrist, Forearm, Elbow, Humerus, Shoulder) 12.2 Lower Limb & Pelvic Girdle Positioning (Foot, Ankle, Leg, Knee, Femur, Pelvis, Hip)
13 Subject 3, Chapter 13: Spine & Bony Thorax
13.1 Cervical, Thoracic & Lumbar Spine Radiography & Trauma Adaptations 13.2 Sacrum, Coccyx, Sacroiliac Joints & Bony Thorax (Ribs & Sternum)
14 Subject 3, Chapter 14: Cranium, Facial Bones & Paranasal Sinuses
14.1 Skull Positioning: Towne, Caldwell, Lateral & SMV Projections 14.2 Facial Bones, Orbits, Zygomatic Arches & Paranasal Sinuses
15 Subject 3, Chapter 15: Contrast Media Studies & Special Procedures
15.1 Gastrointestinal Contrast Procedures (Esophagram, UGI, Small Bowel, Barium Enema) 15.2 Genitourinary, Biliary & Special Fluoroscopic Studies (IVU, Cystography, ERCP, Myelography) 15.3 Reproductive System Studies: Hysterosalpingography, Pelvimetry & Male Reproductive Procedures 15.4 Nasopharyngography, Sialography & Fistulography / Sinus Tract Visualization
16 Subject 4, Chapter 16: Human Anatomy, Physiology & Pathology Integration
16.1 Body System Anatomy & Systemic Physiology Overview for Radiographers 16.2 Radiologic Pathology: Image Manifestations of Neoplastic, Inflammatory & Traumatic Conditions
17 Subject 4, Chapter 17: Patient Assessment, Communication & Informed Consent
17.1 Professional Communication, History Taking & Patient Rights 17.2 Informed Consent, Medical Documentation & Patient Transfer Safety
18 Subject 4, Chapter 18: Infection Control & Vital Signs Monitoring
18.1 Standard Precautions, Asepsis, Sterilization & Isolation Protocols 18.2 Measurement & Assessment of Vital Signs (BP, Pulse, Respiration, Temperature)
19 Subject 4, Chapter 19: Emergency Care & Aseptic Venipuncture
19.1 Basic Life Support (BLS), CPR Concepts & Emergency Response in Radiology 19.2 Aseptic Venipuncture Technique, IV Maintenance & Extravasation Care
20 Subject 4, Chapter 20: Professional Ethics, Jurisprudence & RA 7431
20.1 Republic Act No. 7431 (Radiologic Technology Act of 1992) & Board Rules 20.2 Code of Professional Ethics, Legal Liabilities, Malpractice & Negligence 20.3 Bioethical Principles in Practice, Professional Virtues & Interprofessional Relationships
21 Subject 5, Chapter 21: Diagnostic Ultrasonography
21.1 Ultrasound Physics, Transducer Construction & Doppler Principles 21.2 Acoustic Artifacts, Clinical Applications & Safety (TI/MI) 21.3 Clinical Ultrasound Examinations: Indications, Patient Preparation, Scanning Protocols & Transducer Selection
22 Subject 5, Chapter 22: Computed Tomography (CT)
22.1 CT Physics, Gantry Components, Detectors & Helical/Multislice Acquisition 22.2 Hounsfield Units, Windowing, CT Artifacts & Radiation Dose (CTDI/DLP)
23 Subject 5, Chapter 23: Magnetic Resonance Imaging (MRI)
23.1 MRI Physics, Nuclear Spin, T1/T2 Relaxation & Pulse Sequences 23.2 MRI Safety (Zones I-IV, SAR, Metallic Implants) & Common Artifacts 23.3 MRI Examination Protocols, Patient Preparation, Gadolinium Contrast & Sectional MRI Anatomy
24 Subject 5, Chapter 24: Interventional Radiology & Vascular Imaging
24.1 Vascular Access, Seldinger Technique & Digital Subtraction Angiography (DSA) 24.2 Interventional Procedures (Embolization, Angioplasty, Stenting) & C-Arm Radiation Safety 24.3 Interventional Patient Management: Contrast Selection, Pre-Procedure Workup & Post-Procedure Care
25 Subject 5, Chapter 25: Contrast Media Pharmacology & Adverse Reactions
25.1 Classification of Contrast Agents: Osmolality, Viscosity & Iodine Concentration 25.2 Adverse Contrast Reactions (Mild, Moderate, Severe) & Emergency Treatment Protocols 25.3 General Pharmacologic Principles: Pharmacokinetics, Pharmacodynamics, Drug Categories & the Rights of Drug Safety
26 Subject 5, Chapter 26: Nuclear Medicine & Molecular Imaging
26.1 Radioisotopes, Radiopharmaceuticals & Gamma Camera / SPECT Operation 26.2 Positron Emission Tomography (PET/CT) & Unsealed Radiation Source Safety
27 Subject 5, Chapter 27: Radiation Therapy & Radiation Oncology
27.1 Principles of Radiation Oncology, Linear Accelerators & Treatment Planning 27.2 Teletherapy vs. Brachytherapy, Patient Immobilization & Side Effect Management 27.3 Isodose Planning, Treatment Delivery Methods & Radiobiologic Principles in Radiation Therapy
28 Mammography & Dental Radiography
28.1 Mammography: Equipment, CC and MLO Positioning, Compression & Breast Pathology 28.2 Dental Radiography: Paralleling and Bisecting Techniques, Bitewing, Occlusal, Panoramic & Cephalometric
29 Medical Terminology for Radiologic Technology
29.1 Medical Word Building: Root Words, Combining Forms, Prefixes & Suffixes 29.2 Medical Terms in General Medicine, Abbreviations, Symbols & Critiquing Requests and Reports
30 Radiology Administration, Organization & Leadership
30.1 Organizational Structure, Staffing & Licensing Requirements of a Radiology Facility 30.2 Radiology Department Management: Job Descriptions, Duties, Leadership Styles & Entrepreneurial Skills
25.3 General Pharmacologic Principles: Pharmacokinetics, Pharmacodynamics, Drug Categories & the Rights of Drug Safety
Key Takeaways Explain This Topic AI
Pharmacokinetics is what the body does to the drug — absorption, distribution, metabolism and excretion — while pharmacodynamics is what the drug does to the body through receptor and enzyme interactions.
The rights of drug safety are right patient, right drug, right dose, right route, right time and right documentation, with right reason, right response and right to refuse added in expanded lists.
The intravenous route gives 100 percent bioavailability and the most rapid onset, which is why every intravenous contrast injection demands verification before rather than after administration.
Beam attenuation by a contrast agent depends on its iodine concentration in milligrams per millilitre and on the proximity of the beam energy to the iodine K-edge at 33.2 keV, not on the volume injected alone.
A radiologic technologist administers medication only within the scope authorised by Republic Act No. 7431, under an appropriate order and institutional protocol, and never on personal initiative.
Last updated: August 2026
25.3 General Pharmacologic Principles: Pharmacokinetics, Pharmacodynamics, Drug Categories & the Rights of Drug Safety
General Pharmacologic Principles carries 6 items in the Radiological Sciences subject, and its four competencies are explicit: explain pharmacokinetic and pharmacodynamic principles of drugs ; explain the uses and impact of drug categories and contrast agents' categories on the patient ; illustrate the beam attenuation and pharmacologic profile of contrast agents ; and implement the six rights of drug safety . Sections 25.1 and 25.2 covered contrast classification and adverse reactions. This section supplies the pharmacological framework beneath them.
1. Pharmacokinetics — What the Body Does to the Drug
The four processes, remembered as ADME .
Process Definition Radiology application
Absorption Movement of drug from the site of administration into the bloodstream Intravenous administration bypasses absorption entirely , giving 100% bioavailability and the fastest onset. Oral barium is not absorbed at all, which is what makes it safe as a luminal agent
Distribution Movement from blood into tissues and compartments Iodinated contrast distributes into the extracellular fluid and does not enter normal cells or cross an intact blood-brain barrier — which is precisely why a lesion that breaks that barrier enhances
Metabolism (biotransformation) Chemical alteration, mainly hepatic Iodinated contrast is not significantly metabolised ; it is excreted unchanged
Excretion Elimination from the body Iodinated contrast is excreted by glomerular filtration through the kidneys, which is why renal function determines both clearance and risk
Terms to be able to define:
Bioavailability — the fraction of an administered dose that reaches the systemic circulation unchanged; 100% for the intravenous route by definition.
Half-life — the time for the plasma concentration to fall by half. Iodinated contrast has a plasma half-life of roughly 1-2 hours in normal renal function, prolonged markedly in renal impairment.
Onset, peak and duration — the practical timing parameters. For intravenous contrast, onset is seconds, which is why a reaction can begin before the injection finishes.
Therapeutic index — the ratio between the toxic dose and the effective dose. A narrow index means small errors matter greatly.
First-pass effect — hepatic metabolism of an orally administered drug before it reaches the systemic circulation; a reason why oral doses exceed intravenous doses of the same agent.
Route comparison
- Route Onset Bioavailability Comment
- Intravenous (IV) Seconds 100% Fastest, most controllable, least reversible once given
Intramuscular (IM) Minutes High Adrenaline for anaphylaxis is given intramuscularly into the anterolateral thigh
- Subcutaneous (SC) Slower High Small volumes
- Oral (PO) 30-90 minutes Variable; subject to first-pass metabolism Barium, oral contrast, premedication
- Rectal (PR) Variable Partial first-pass bypass Barium enema, some antiemetics
- Inhalational Seconds to minutes High Bronchodilators for contrast-induced bronchospasm
- Sublingual 1-3 minutes Bypasses first pass Glyceryl trinitrate
- Topical / transdermal Slow Variable Local anaesthetic cream before cannulation in children
Intrathecal Immediate local — Myelography only , and only with an agent labelled for intrathecal use ; injecting a non-intrathecal agent causes fatal neurotoxicity
The intrathecal rule is examined and must be absolute: verify the label reads "for intrathecal use" before any myelographic injection.
2. Pharmacodynamics — What the Drug Does to the Body
Drugs act by binding to receptors , by inhibiting or activating enzymes , by altering ion channels , or by direct physicochemical effect.
- Term Meaning Radiology example
- Agonist Binds a receptor and produces the effect Adrenaline on alpha and beta receptors in anaphylaxis
Antagonist Binds a receptor and blocks the effect Naloxone reversing opioid respiratory depression; flumazenil reversing benzodiazepine sedation
- Partial agonist Produces a submaximal effect —
- Potency Amount of drug needed for a given effect —
- Efficacy Maximum achievable effect —
Side effect Predictable, dose-related, non-therapeutic effect Warmth and metallic taste with contrast injection
- Adverse drug reaction Harmful, unintended response Contrast-induced urticaria
- Idiosyncratic reaction Unpredictable, not dose-related Rare anaphylactoid response
Synergism / potentiation Combined effect greater than additive Opioid plus benzodiazepine — the classic sedation hazard
Antagonism One drug reduces another's effect Beta blockers blunt the response to adrenaline , which is why an anaphylactic patient on a beta blocker may need glucagon
- Tolerance / dependence Reduced effect with repeat exposure / physiological need Relevant in sedation practice
- 3. Drug Categories Encountered in Imaging
Category Examples Imaging relevance
Contrast agents Iodinated (ionic and non-ionic), barium sulphate, gadolinium chelates, microbubble ultrasound agents, carbon dioxide The core of the department's formulary
Emergency drugs Adrenaline (epinephrine) , atropine, salbutamol, hydrocortisone, diphenhydramine, oxygen, intravenous fluids Must be immediately available wherever contrast is injected
Analgesics Paracetamol, NSAIDs, opioids such as fentanyl and morphine Interventional and painful procedures
Sedatives and anxiolytics Midazolam, diazepam Conscious sedation; requires monitoring and a reversal agent on hand
Local anaesthetics Lidocaine Access-site infiltration; watch total dose and inadvertent intravascular injection
Antiemetics Metoclopramide, ondansetron Contrast-related nausea
Antispasmodics Hyoscine butylbromide, glucagon Reduce bowel peristalsis in barium and cross-sectional bowel studies
Anticoagulants and antiplatelets Heparin, warfarin, direct oral anticoagulants, aspirin, clopidogrel Determine bleeding risk in interventional work
- Diuretics Furosemide Diuretic renography
- Radiopharmaceuticals Technetium-99m labelled agents, fluorine-18 FDG, iodine-131 Nuclear medicine
Others with imaging consequences Metformin (management around iodinated contrast in renal impairment), beta blockers (blunt the response to adrenaline and are used for heart-rate control in cardiac CT) —
4. Beam Attenuation and the Pharmacologic Profile of Contrast
The TOS asks specifically for this link.
Attenuation depends on:
Iodine concentration , expressed in milligrams of iodine per millilitre (typically about 300-370 mgI/mL for intravascular agents). Higher concentration means greater attenuation per unit volume.
Proximity of the beam's photon energy to the iodine K-edge at 33.2 keV. Attenuation is maximal just above the K-edge and falls away at higher energies — which is why excessively high kVp wastes contrast , and why dual-energy and spectral CT can separate iodine from calcium.
Total iodine delivered — concentration times volume times injection rate — which drives the peak arterial enhancement in a CT angiogram.
The patient's circulation — cardiac output, body weight and vascular access calibre all shift the timing of peak enhancement, which is why bolus tracking exists.
The pharmacologic profile that must be balanced against attenuation:
Property Consequence
Osmolality High osmolality draws water into the vascular space, causing pain, heat, vasodilation, endothelial injury, and haemodynamic shift. Non-ionic low-osmolar and iso-osmolar agents were developed to reduce this
Viscosity Determines injectability through fine catheters; warming reduces viscosity
Ionicity Ionic agents dissociate into ions, doubling the osmotic particles per molecule; non-ionic agents do not dissociate
Chemotoxicity Direct molecular toxicity, independent of osmolality
Protein binding and hydrophilicity Greater hydrophilicity and lower protein binding reduce biological interaction and toxicity
Barium sulphate is pharmacologically different: it is an inert, insoluble suspension that is not absorbed , has no systemic pharmacology, and is contraindicated wherever perforation or leakage into the peritoneum is suspected, or where aspiration is likely — situations in which water-soluble iodinated contrast is substituted.
5. The Rights of Drug Safety
The classical six rights , which the TOS names explicitly:
- Right What you verify
- 1. Right patient Two identifiers obtained from the patient , checked against the request and the prescription
2. Right drug The label read three times — when taking the container, when drawing up, and when discarding. Check for look-alike and sound-alike names
- 3. Right dose Calculated and, for high-risk drugs, independently double-checked; weight-based where applicable
- 4. Right route Intravenous, intramuscular, oral, rectal, intrathecal only with an intrathecal-labelled agent
- 5. Right time Correct timing relative to the scan phase, the fast, or the previous dose
6. Right documentation Drug, dose, route, time, site, batch or lot number, expiry, and the administering person recorded immediately after administration, never before
Expanded lists add: right reason (a valid indication), right response (assess and document the effect), right to refuse (the patient may decline), and right education (the patient understands what is being given and what to report).
Before every injection also check: expiry date, container integrity, clarity and absence of particulate matter, that the correct concentration was selected, and that patency of the cannula has been confirmed with a saline flush. After every injection: flush, observe the patient for the critical first 15-20 minutes , and document.
6. Scope of Practice — The Boundary That Matters
Under RA 7431 , medication administration by a radiologic technologist is permitted only:
- Within the scope authorised by the credential held , and consistent with the Board's rules;
- On the order of a physician or under an approved institutional protocol;
After documented training and competency assessment in cannulation, contrast administration and reaction management;
With a physician immediately available for contrast and interventional work;
Never on the technologist's own initiative , and never a drug the technologist is not authorised and trained to give.
The Enhanced TOS reinforces this in the very next sub-topic, which asks the examinee to recognize the legal, ethical, and professional liability issues of the Radiologic Technologist's role in contrast media administration. Administering outside scope is simultaneously a negligence exposure and a violation of RA 7431.
The technologist is also the last check. Even where another professional prescribes and another draws up, the person pushing the syringe verifies the six rights. "I was told to give it" is not a defence.