Study guide

21.2 Acoustic Artifacts, Clinical Applications & Safety (TI/MI)

Philippine Radiologic Technologists Licensure Examination Exam

Track your progress as you read

Finished sections get a check mark.

1 Subject 1, Chapter 1: Physics of Radiology & X-Ray Production

1.1 Atomic Structure, Electromagnetic Spectrum & X-Ray Production Mechanisms 1.2 X-Ray Tube Components, Target Interactions & Emission Spectrum 1.3 Photon Interactions with Matter: Photoelectric, Compton, Coherent & Pair Production

2 Subject 1, Chapter 2: Radiographic Equipment & Circuitry

2.1 High-Voltage Generators, Transformers & Rectification Circuits 2.2 Automatic Exposure Control (AEC), Beam Restriction & Quality Control 2.3 Tube Rating Charts, Extending Tube Life, Mechanical Malfunction & Preventive Maintenance

3 Subject 1, Chapter 3: Radiobiology & Cellular Response

3.1 Radiation Interaction with Tissue, Direct/Indirect Action & LET/RBE 3.2 Law of Bergonie & Tribondeau, Deterministic vs. Stochastic Effects 3.3 Dose-Response Relationships, Embryo and Fetal Effects & Acute Radiation Syndrome

4 Subject 1, Chapter 4: Radiation Protection & Dose Limits

4.1 ALARA Principles, Structural Shielding & Dose Limits 4.2 Personnel Dosimetry & Patient Dose Reduction Techniques 4.3 Dose Calculation Problems: Time, Distance, Shielding & Structural Barrier Design

5 Subject 1, Chapter 5: Imaging Informatics & Quality Assurance

5.1 PACS Architecture, DICOM Standards & HL7 Integration 5.2 Quality Assurance & Quality Control Protocols in Diagnostic Radiography 5.3 Radiology Workflow, RIS/HIS Integration, Teleradiology & Informatics Quality Assurance

6 Subject 2, Chapter 6: Film-Screen Radiography & Sensitometry

6.1 Film Emulsion, Latent Image Formation & Darkroom Chemistry 6.2 Sensitometric Curve (H&D Curve), Film Speed & Contrast Characteristics 6.3 Radiographic Film Analysis: Processing Faults, Handling Artifacts & Corrective Measures

7 Subject 2, Chapter 7: Technical Factors & Radiographic Quality

7.1 Density/Brightness, Contrast, Spatial Resolution & Distortion Controls 7.2 Exposure Math: Inverse Square Law, 15% Rule & Grid Conversion Factors 7.3 Technique Compensation: Age, Pathology, Cast and Orthopaedic Devices, Screen Speed & Beam Restriction

8 Subject 2, Chapter 8: Computed Radiography (CR)

8.1 Photostimulable Phosphor (PSP) Plates & CR Reader Mechanics 8.2 Image Processing, CR Artifacts & Erasure Protocols

9 Subject 2, Chapter 9: Digital Radiography (DR)

9.1 Flat-Panel Detectors: Direct vs. Indirect Conversion & TFT Arrays 9.2 Detective Quantum Efficiency (DQE), Modulation Transfer Function (MTF) & Dynamic Range

10 Subject 2, Chapter 10: Exposure Indicators & Image Evaluation

10.1 Exposure Indicators (S-Number, EI, DI), Windowing & Look-Up Tables (LUT) 10.2 Image Critique Checklist, Artifact Identification & Quality Control Standards 10.3 Image Display & Hard-Copy Output: Monitor Classification, DICOM GSDF, Dry vs Wet Laser Imaging

11 Subject 3, Chapter 11: Chest, Abdomen & Routine Positioning Concepts

11.1 Anatomical Terminology, Body Planes & Chest Radiography (PA, Lateral, Decubitus) 11.2 Abdominal Radiography: Acute Abdomen Series & Erect/Supine Protocols 11.3 Radiologic Surface Anatomy, Body Habitus & Sectional Body Cuts

12 Subject 3, Chapter 12: Upper & Lower Extremities & Girdles

12.1 Upper Limb & Shoulder Girdle Positioning (Hand, Wrist, Forearm, Elbow, Humerus, Shoulder) 12.2 Lower Limb & Pelvic Girdle Positioning (Foot, Ankle, Leg, Knee, Femur, Pelvis, Hip)

13 Subject 3, Chapter 13: Spine & Bony Thorax

13.1 Cervical, Thoracic & Lumbar Spine Radiography & Trauma Adaptations 13.2 Sacrum, Coccyx, Sacroiliac Joints & Bony Thorax (Ribs & Sternum)

14 Subject 3, Chapter 14: Cranium, Facial Bones & Paranasal Sinuses

14.1 Skull Positioning: Towne, Caldwell, Lateral & SMV Projections 14.2 Facial Bones, Orbits, Zygomatic Arches & Paranasal Sinuses

15 Subject 3, Chapter 15: Contrast Media Studies & Special Procedures

15.1 Gastrointestinal Contrast Procedures (Esophagram, UGI, Small Bowel, Barium Enema) 15.2 Genitourinary, Biliary & Special Fluoroscopic Studies (IVU, Cystography, ERCP, Myelography) 15.3 Reproductive System Studies: Hysterosalpingography, Pelvimetry & Male Reproductive Procedures 15.4 Nasopharyngography, Sialography & Fistulography / Sinus Tract Visualization

16 Subject 4, Chapter 16: Human Anatomy, Physiology & Pathology Integration

16.1 Body System Anatomy & Systemic Physiology Overview for Radiographers 16.2 Radiologic Pathology: Image Manifestations of Neoplastic, Inflammatory & Traumatic Conditions

17 Subject 4, Chapter 17: Patient Assessment, Communication & Informed Consent

17.1 Professional Communication, History Taking & Patient Rights 17.2 Informed Consent, Medical Documentation & Patient Transfer Safety

18 Subject 4, Chapter 18: Infection Control & Vital Signs Monitoring

18.1 Standard Precautions, Asepsis, Sterilization & Isolation Protocols 18.2 Measurement & Assessment of Vital Signs (BP, Pulse, Respiration, Temperature)

19 Subject 4, Chapter 19: Emergency Care & Aseptic Venipuncture

19.1 Basic Life Support (BLS), CPR Concepts & Emergency Response in Radiology 19.2 Aseptic Venipuncture Technique, IV Maintenance & Extravasation Care

20 Subject 4, Chapter 20: Professional Ethics, Jurisprudence & RA 7431

20.1 Republic Act No. 7431 (Radiologic Technology Act of 1992) & Board Rules 20.2 Code of Professional Ethics, Legal Liabilities, Malpractice & Negligence 20.3 Bioethical Principles in Practice, Professional Virtues & Interprofessional Relationships

21 Subject 5, Chapter 21: Diagnostic Ultrasonography

21.1 Ultrasound Physics, Transducer Construction & Doppler Principles 21.2 Acoustic Artifacts, Clinical Applications & Safety (TI/MI) 21.3 Clinical Ultrasound Examinations: Indications, Patient Preparation, Scanning Protocols & Transducer Selection

22 Subject 5, Chapter 22: Computed Tomography (CT)

22.1 CT Physics, Gantry Components, Detectors & Helical/Multislice Acquisition 22.2 Hounsfield Units, Windowing, CT Artifacts & Radiation Dose (CTDI/DLP)

23 Subject 5, Chapter 23: Magnetic Resonance Imaging (MRI)

23.1 MRI Physics, Nuclear Spin, T1/T2 Relaxation & Pulse Sequences 23.2 MRI Safety (Zones I-IV, SAR, Metallic Implants) & Common Artifacts 23.3 MRI Examination Protocols, Patient Preparation, Gadolinium Contrast & Sectional MRI Anatomy

24 Subject 5, Chapter 24: Interventional Radiology & Vascular Imaging

24.1 Vascular Access, Seldinger Technique & Digital Subtraction Angiography (DSA) 24.2 Interventional Procedures (Embolization, Angioplasty, Stenting) & C-Arm Radiation Safety 24.3 Interventional Patient Management: Contrast Selection, Pre-Procedure Workup & Post-Procedure Care

25 Subject 5, Chapter 25: Contrast Media Pharmacology & Adverse Reactions

25.1 Classification of Contrast Agents: Osmolality, Viscosity & Iodine Concentration 25.2 Adverse Contrast Reactions (Mild, Moderate, Severe) & Emergency Treatment Protocols 25.3 General Pharmacologic Principles: Pharmacokinetics, Pharmacodynamics, Drug Categories & the Rights of Drug Safety

26 Subject 5, Chapter 26: Nuclear Medicine & Molecular Imaging

26.1 Radioisotopes, Radiopharmaceuticals & Gamma Camera / SPECT Operation 26.2 Positron Emission Tomography (PET/CT) & Unsealed Radiation Source Safety

27 Subject 5, Chapter 27: Radiation Therapy & Radiation Oncology

27.1 Principles of Radiation Oncology, Linear Accelerators & Treatment Planning 27.2 Teletherapy vs. Brachytherapy, Patient Immobilization & Side Effect Management 27.3 Isodose Planning, Treatment Delivery Methods & Radiobiologic Principles in Radiation Therapy

28 Mammography & Dental Radiography

28.1 Mammography: Equipment, CC and MLO Positioning, Compression & Breast Pathology 28.2 Dental Radiography: Paralleling and Bisecting Techniques, Bitewing, Occlusal, Panoramic & Cephalometric

29 Medical Terminology for Radiologic Technology

29.1 Medical Word Building: Root Words, Combining Forms, Prefixes & Suffixes 29.2 Medical Terms in General Medicine, Abbreviations, Symbols & Critiquing Requests and Reports

30 Radiology Administration, Organization & Leadership

30.1 Organizational Structure, Staffing & Licensing Requirements of a Radiology Facility 30.2 Radiology Department Management: Job Descriptions, Duties, Leadership Styles & Entrepreneurial Skills

21.2 Acoustic Artifacts, Clinical Applications & Safety (TI/MI)

Key Takeaways Explain This Topic AI

A-mode presents 1D amplitude spikes, B-mode constructs 2D grayscale brightness images, and M-mode traces structural motion over time.

Acoustic shadowing results from high attenuation distally (gallstones, bone), whereas acoustic enhancement distally occurs distally to low-attenuation fluid cysts.

Reverberation artifact displays equally spaced false parallel echo lines produced by sound bouncing between two strong specular reflectors.

Thermal Index (TI) quantifies tissue heating potential, while Mechanical Index (MI = P_neg / sqrt(f0)) predicts acoustic cavitation risk.

Under ALARA principles, no confirmed bioeffects occur in mammalian tissues at Mechanical Index < 1.9 or Thermal Index < 1.0.

Last updated: August 2026

21.2 Acoustic Artifacts, Clinical Applications & Safety (TI/MI)

In diagnostic ultrasound, accurate interpretation requires recognizing image artifacts—structures displayed in the image that do not accurately represent real anatomy. Furthermore, radiologic technologists must enforce bioeffect safety guidelines using output display indices to ensure patient safety under the ALARA principle.

1. Ultrasound Display Modes

Diagnostic sonographic instruments process returning acoustic echoes into three primary display formats:

A-Mode (Amplitude Mode)

Format: A one-dimensional graphical plot where the vertical axis (Y-axis) represents echo amplitude (spike height) and the horizontal axis (X-axis) represents reflector depth .

Mechanism: Stronger returning echoes generate higher vertical amplitude spikes.

Clinical Use: Historically used in echoencephalography; currently used in ophthalmology for precise intraocular distance measurements.

B-Mode (Brightness Mode)

Format: A two-dimensional grayscale image where returning echo amplitudes are converted into dots of varying brightness .

Mechanism: An echo's position corresponds to reflector depth (Y-axis) and lateral beam position (X-axis). Dot intensity/brightness directly reflects echo amplitude (white = hyperechoic/strong; black = anechoic/none).

Clinical Use: The foundation for all modern real-time 2D grayscale anatomical imaging.

M-Mode (Motion Mode)

Format: A group of quantitative lines displaying structural motion over time. The vertical axis represents depth , the horizontal axis represents time , and echo brightness represents amplitude.

Mechanism: A single acoustic scan line continuously samples moving cardiac structures.

Clinical Use: Echocardiography to evaluate heart valve leaflet movement, chamber wall dynamics, and precise fetal heart rate (FHR) measurement.

2. Acoustic Artifacts

An artifact in sonography is an error in imaging—an echo density that is extra, missing, misplaced, or incorrect in size, shape, or brightness. Most artifacts occur when sound fails to follow basic physics assumptions (e.g., sound travels in a straight line at exactly 1540 m/s). +-----------------------+-------------------------------------------------+----------------------------------------+

| Acoustic Artifact | Underlying Physics Mechanism | Typical Clinical Example |

+-----------------------+-------------------------------------------------+----------------------------------------+

  • | Acoustic Shadowing | Sound beam undergoes high attenuation or near- | Dense gallstones, renal calculi, |
  • | | total reflection; distal tissue receives no sound.| bone interfaces, surgical clips. |

+-----------------------+-------------------------------------------------+----------------------------------------+

| Acoustic Enhancement | Sound beam travels through low-attenuating fluid| Simple hepatic cysts, renal cysts, |

| (Posterior) | medium; distal echoes appear abnormally bright. | distended urinary bladder. |

+-----------------------+-------------------------------------------------+----------------------------------------+

  • | Reverberation | Sound bounces back and forth between two strong | Metallic foreign bodies, surgical |
  • | | parallel specular reflectors; creates ladder. | staples, pleural line interfaces. |

+-----------------------+-------------------------------------------------+----------------------------------------+

  • | Comet-Tail / Ring-Down| Form of reverberation with closely spaced | Adenomyomatosis of gallbladder, gas |
  • | | echoes forming a solid trailing line. | bubbles in bowel / soft tissue. |

+-----------------------+-------------------------------------------------+----------------------------------------+

  • | Refraction (Edge) | Sound beam bends at oblique interfaces between | Lateral shadow edges of kidney cysts |
  • | | media with different speeds; creates false shadow.| or round fetal head structures. |

+-----------------------+-------------------------------------------------+----------------------------------------+

  • | Speed Error | Medium speed differs from 1540 m/s; structures | Fat lobules or silicone implants |
  • | | are placed at incorrect depths on display. | causing displaced diaphragm line. |

+-----------------------+-------------------------------------------------+----------------------------------------+

  • | Side / Grating Lobes | Off-axis acoustic energy beams outside main | False debris/echoes within anechoic |
  • | | ultrasound beam produce extraneous reflections.| urinary bladder or gallbladder lumen. |

+-----------------------+-------------------------------------------------+----------------------------------------+

Detailed Breakdown of Key Artifacts

Acoustic Shadowing (Acoustic Attenuation Shadowing): High-attenuation structures absorb or reflect almost all acoustic energy. The region directly posterior to the structure is devoid of sound, creating a dark, anechoic band. Essential diagnostic feature for confirming cholelithiasis (gallstones) and nephrolithiasis (kidney stones).

Posterior Acoustic Enhancement (Increased Through-Transmission): Fluid attenuates sound significantly less than soft tissue. Sound passing through a fluid medium retains high intensity, causing tissue directly behind the fluid to appear falsely hyperechoic (bright white). Essential for confirming fluid-filled simple cysts .

Reverberation Artifact: Appears as multiple, equally spaced linear echo lines parallel to the transducer face. Occurs when sound ping-pongs between two strong specular reflectors.

3. Core Clinical Applications

Abdominal Sonography: Evaluation of solid abdominal organs including liver parenchymal liver disease, gallbladder acute cholecystitis, biliary tree dilation, pancreatic masses, renal cyst vs. solid tumor differentiation, and abdominal aortic aneurysm (AAA) screening.

Small Parts & Superficial Imaging: Employs high-frequency linear transducers (7–15 MHz) for fine anatomical resolution of the thyroid gland (nodule evaluation), scrotum/testis (torsion vs. epididymitis), breast masses (cystic vs. solid breast lesions), and musculoskeletal tendons.

Obstetrics & Gynecology (OB/GYN): Transabdominal and high-frequency transvaginal scanning to establish gestational age (crown-rump length CRL, biparietal diameter BPD, femur length FL), anatomical anomaly screening, placental location, biophysical profile (BPP), and gynecologic evaluation of uterine fibroids or ovarian cysts.

Vascular Sonography: Carotid artery duplex scanning to quantify atherosclerotic stenosis, lower extremity venous scanning for Deep Vein Thrombosis (DVT), and peripheral arterial insufficiency assessment.

4. Bioeffects & Ultrasound Safety (TI & MI)

Although diagnostic ultrasound is non-ionizing radiation and safe, acoustic energy deposited in human tissues can induce biological effects through two primary mechanisms: thermal (heating) and mechanical (cavitation) .

Output Display Standard (ODS)

Modern ultrasound machines display real-time safety indices on screen to inform the operator of acoustic power output:

Thermal Index (TI): A ratio reflecting the relative potential for tissue temperature rise. A TI of 1.0 indicates that output conditions could produce a maximum temperature rise of 1.0 ∘ C 1.0^\circ\text{C} 1. 0 ∘ C in tissue under specific exposure models.

TIS (Thermal Index Soft Tissue): Used during general soft tissue imaging.

TIB (Thermal Index Bone): Used when sound beam focuses near bone (e.g., second/third trimester OB fetal head scanning).

TIC (Thermal Index Cranial): Used when the transducer rests on cranial bone (e.g., adult transcranial Doppler).

Mechanical Index (MI): Indicates the likelihood of non-thermal bioeffects, primarily acoustic cavitation (the interaction of ultrasound waves with microscopic gas bodies in tissue): MI = P neg f 0 \text{MI} = \frac{P_{\text{neg}}}{\sqrt{f_0}} MI = f 0 ​ ​ P neg ​ ​

Where P neg P_{\text{neg}} P neg ​ is peak rarefactional pressure and f 0 f_0 f 0 ​ is transducer center frequency.

Types of Cavitation

Stable Cavitation: Microbubbles expand and contract rhythmically in response to pressure waves without bursting. Microstreaming of tissue fluids surrounding bubbles causes localized shear stress.

Transient (Collapse) Cavitation: Microbubbles expand excessively during rarefaction and violently collapse during compression, producing localized extreme temperatures (thousands of degrees) and localized shock waves. Highly destructive at cellular levels.

ALARA Principle & Safety Guidelines

ALARA Principle: As Low As Reasonably Achievable . Operators must minimize acoustic output power and total exposure dwell time while obtaining diagnostic quality images.

Safety Thresholds (AIUM / NEMA Guidelines): No confirmed adverse bioeffects have been documented in mammalian tissues exposed to diagnostic ultrasound under the following limits:

Unfocused ultrasound beams: Intensity below 100 mW/cm 2 100\text{ mW/cm}^2 100 mW/cm 2 (SPTA) .

Focused ultrasound beams: Intensity below 1 W/cm 2 1\text{ W/cm}^2 1 W/cm 2 (1000 mW/cm 2 ^2 2 SPTA) .

Mechanical Index (MI): Kept < 1.9 < 1.9 < 1.9 .

Thermal Index (TI): Kept < 1.0 < 1.0 < 1.0 (especially during sensitive early obstetric imaging).