Study guide
21.3 Clinical Ultrasound Examinations: Indications, Patient Preparation, Scanning Protocols & Transducer Selection
Philippine Radiologic Technologists Licensure Examination Exam
Track your progress as you read
Finished sections get a check mark.
1 Subject 1, Chapter 1: Physics of Radiology & X-Ray Production
1.1 Atomic Structure, Electromagnetic Spectrum & X-Ray Production Mechanisms 1.2 X-Ray Tube Components, Target Interactions & Emission Spectrum 1.3 Photon Interactions with Matter: Photoelectric, Compton, Coherent & Pair Production
2 Subject 1, Chapter 2: Radiographic Equipment & Circuitry
2.1 High-Voltage Generators, Transformers & Rectification Circuits 2.2 Automatic Exposure Control (AEC), Beam Restriction & Quality Control 2.3 Tube Rating Charts, Extending Tube Life, Mechanical Malfunction & Preventive Maintenance
3 Subject 1, Chapter 3: Radiobiology & Cellular Response
3.1 Radiation Interaction with Tissue, Direct/Indirect Action & LET/RBE 3.2 Law of Bergonie & Tribondeau, Deterministic vs. Stochastic Effects 3.3 Dose-Response Relationships, Embryo and Fetal Effects & Acute Radiation Syndrome
4 Subject 1, Chapter 4: Radiation Protection & Dose Limits
4.1 ALARA Principles, Structural Shielding & Dose Limits 4.2 Personnel Dosimetry & Patient Dose Reduction Techniques 4.3 Dose Calculation Problems: Time, Distance, Shielding & Structural Barrier Design
5 Subject 1, Chapter 5: Imaging Informatics & Quality Assurance
5.1 PACS Architecture, DICOM Standards & HL7 Integration 5.2 Quality Assurance & Quality Control Protocols in Diagnostic Radiography 5.3 Radiology Workflow, RIS/HIS Integration, Teleradiology & Informatics Quality Assurance
6 Subject 2, Chapter 6: Film-Screen Radiography & Sensitometry
6.1 Film Emulsion, Latent Image Formation & Darkroom Chemistry 6.2 Sensitometric Curve (H&D Curve), Film Speed & Contrast Characteristics 6.3 Radiographic Film Analysis: Processing Faults, Handling Artifacts & Corrective Measures
7 Subject 2, Chapter 7: Technical Factors & Radiographic Quality
7.1 Density/Brightness, Contrast, Spatial Resolution & Distortion Controls 7.2 Exposure Math: Inverse Square Law, 15% Rule & Grid Conversion Factors 7.3 Technique Compensation: Age, Pathology, Cast and Orthopaedic Devices, Screen Speed & Beam Restriction
8 Subject 2, Chapter 8: Computed Radiography (CR)
8.1 Photostimulable Phosphor (PSP) Plates & CR Reader Mechanics 8.2 Image Processing, CR Artifacts & Erasure Protocols
9 Subject 2, Chapter 9: Digital Radiography (DR)
9.1 Flat-Panel Detectors: Direct vs. Indirect Conversion & TFT Arrays 9.2 Detective Quantum Efficiency (DQE), Modulation Transfer Function (MTF) & Dynamic Range
10 Subject 2, Chapter 10: Exposure Indicators & Image Evaluation
10.1 Exposure Indicators (S-Number, EI, DI), Windowing & Look-Up Tables (LUT) 10.2 Image Critique Checklist, Artifact Identification & Quality Control Standards 10.3 Image Display & Hard-Copy Output: Monitor Classification, DICOM GSDF, Dry vs Wet Laser Imaging
11 Subject 3, Chapter 11: Chest, Abdomen & Routine Positioning Concepts
11.1 Anatomical Terminology, Body Planes & Chest Radiography (PA, Lateral, Decubitus) 11.2 Abdominal Radiography: Acute Abdomen Series & Erect/Supine Protocols 11.3 Radiologic Surface Anatomy, Body Habitus & Sectional Body Cuts
12 Subject 3, Chapter 12: Upper & Lower Extremities & Girdles
12.1 Upper Limb & Shoulder Girdle Positioning (Hand, Wrist, Forearm, Elbow, Humerus, Shoulder) 12.2 Lower Limb & Pelvic Girdle Positioning (Foot, Ankle, Leg, Knee, Femur, Pelvis, Hip)
13 Subject 3, Chapter 13: Spine & Bony Thorax
13.1 Cervical, Thoracic & Lumbar Spine Radiography & Trauma Adaptations 13.2 Sacrum, Coccyx, Sacroiliac Joints & Bony Thorax (Ribs & Sternum)
14 Subject 3, Chapter 14: Cranium, Facial Bones & Paranasal Sinuses
14.1 Skull Positioning: Towne, Caldwell, Lateral & SMV Projections 14.2 Facial Bones, Orbits, Zygomatic Arches & Paranasal Sinuses
15 Subject 3, Chapter 15: Contrast Media Studies & Special Procedures
15.1 Gastrointestinal Contrast Procedures (Esophagram, UGI, Small Bowel, Barium Enema) 15.2 Genitourinary, Biliary & Special Fluoroscopic Studies (IVU, Cystography, ERCP, Myelography) 15.3 Reproductive System Studies: Hysterosalpingography, Pelvimetry & Male Reproductive Procedures 15.4 Nasopharyngography, Sialography & Fistulography / Sinus Tract Visualization
16 Subject 4, Chapter 16: Human Anatomy, Physiology & Pathology Integration
16.1 Body System Anatomy & Systemic Physiology Overview for Radiographers 16.2 Radiologic Pathology: Image Manifestations of Neoplastic, Inflammatory & Traumatic Conditions
17 Subject 4, Chapter 17: Patient Assessment, Communication & Informed Consent
17.1 Professional Communication, History Taking & Patient Rights 17.2 Informed Consent, Medical Documentation & Patient Transfer Safety
18 Subject 4, Chapter 18: Infection Control & Vital Signs Monitoring
18.1 Standard Precautions, Asepsis, Sterilization & Isolation Protocols 18.2 Measurement & Assessment of Vital Signs (BP, Pulse, Respiration, Temperature)
19 Subject 4, Chapter 19: Emergency Care & Aseptic Venipuncture
19.1 Basic Life Support (BLS), CPR Concepts & Emergency Response in Radiology 19.2 Aseptic Venipuncture Technique, IV Maintenance & Extravasation Care
20 Subject 4, Chapter 20: Professional Ethics, Jurisprudence & RA 7431
20.1 Republic Act No. 7431 (Radiologic Technology Act of 1992) & Board Rules 20.2 Code of Professional Ethics, Legal Liabilities, Malpractice & Negligence 20.3 Bioethical Principles in Practice, Professional Virtues & Interprofessional Relationships
21 Subject 5, Chapter 21: Diagnostic Ultrasonography
21.1 Ultrasound Physics, Transducer Construction & Doppler Principles 21.2 Acoustic Artifacts, Clinical Applications & Safety (TI/MI) 21.3 Clinical Ultrasound Examinations: Indications, Patient Preparation, Scanning Protocols & Transducer Selection
22 Subject 5, Chapter 22: Computed Tomography (CT)
22.1 CT Physics, Gantry Components, Detectors & Helical/Multislice Acquisition 22.2 Hounsfield Units, Windowing, CT Artifacts & Radiation Dose (CTDI/DLP)
23 Subject 5, Chapter 23: Magnetic Resonance Imaging (MRI)
23.1 MRI Physics, Nuclear Spin, T1/T2 Relaxation & Pulse Sequences 23.2 MRI Safety (Zones I-IV, SAR, Metallic Implants) & Common Artifacts 23.3 MRI Examination Protocols, Patient Preparation, Gadolinium Contrast & Sectional MRI Anatomy
24 Subject 5, Chapter 24: Interventional Radiology & Vascular Imaging
24.1 Vascular Access, Seldinger Technique & Digital Subtraction Angiography (DSA) 24.2 Interventional Procedures (Embolization, Angioplasty, Stenting) & C-Arm Radiation Safety 24.3 Interventional Patient Management: Contrast Selection, Pre-Procedure Workup & Post-Procedure Care
25 Subject 5, Chapter 25: Contrast Media Pharmacology & Adverse Reactions
25.1 Classification of Contrast Agents: Osmolality, Viscosity & Iodine Concentration 25.2 Adverse Contrast Reactions (Mild, Moderate, Severe) & Emergency Treatment Protocols 25.3 General Pharmacologic Principles: Pharmacokinetics, Pharmacodynamics, Drug Categories & the Rights of Drug Safety
26 Subject 5, Chapter 26: Nuclear Medicine & Molecular Imaging
26.1 Radioisotopes, Radiopharmaceuticals & Gamma Camera / SPECT Operation 26.2 Positron Emission Tomography (PET/CT) & Unsealed Radiation Source Safety
27 Subject 5, Chapter 27: Radiation Therapy & Radiation Oncology
27.1 Principles of Radiation Oncology, Linear Accelerators & Treatment Planning 27.2 Teletherapy vs. Brachytherapy, Patient Immobilization & Side Effect Management 27.3 Isodose Planning, Treatment Delivery Methods & Radiobiologic Principles in Radiation Therapy
28 Mammography & Dental Radiography
28.1 Mammography: Equipment, CC and MLO Positioning, Compression & Breast Pathology 28.2 Dental Radiography: Paralleling and Bisecting Techniques, Bitewing, Occlusal, Panoramic & Cephalometric
29 Medical Terminology for Radiologic Technology
29.1 Medical Word Building: Root Words, Combining Forms, Prefixes & Suffixes 29.2 Medical Terms in General Medicine, Abbreviations, Symbols & Critiquing Requests and Reports
30 Radiology Administration, Organization & Leadership
30.1 Organizational Structure, Staffing & Licensing Requirements of a Radiology Facility 30.2 Radiology Department Management: Job Descriptions, Duties, Leadership Styles & Entrepreneurial Skills
21.3 Clinical Ultrasound Examinations: Indications, Patient Preparation, Scanning Protocols & Transducer Selection
Key Takeaways Explain This Topic AI
Transabdominal pelvic and obstetric first-trimester scanning requires a full urinary bladder as an acoustic window, whereas transvaginal scanning requires an empty bladder and provides higher resolution at shallower depth.
Upper abdominal and biliary scanning requires fasting for about 6 to 8 hours so that the gallbladder is distended and bowel gas is reduced.
Transducer frequency is chosen as a trade-off: high frequency of about 7 to 15 MHz gives superior resolution at shallow depth for thyroid, breast, testis and vascular access, while low frequency of about 2 to 5 MHz gives the penetration needed for abdominal, obstetric and cardiac work.
The Focused Assessment with Sonography for Trauma examination interrogates four regions — right upper quadrant hepatorenal recess, left upper quadrant splenorenal recess, pelvis and subxiphoid pericardium — for free fluid.
Ultrasound is the first-line modality in pregnancy, in paediatric and neonatal imaging, in the acute scrotum and in breast assessment under about 30 years of age, because it is non-ionising, real-time and portable.
Last updated: August 2026
21.3 Clinical Ultrasound Examinations: Indications, Patient Preparation, Scanning Protocols & Transducer Selection
Anatomical Presentation During Real Time Scanning is the largest sub-topic of Ultrasonography at 6 items , and its competencies are practical: explain the different ultrasound examinations as to rationale and indication, procedure and preparation, and appropriate devices and equipment , and perform the various examination and scanning procedures in medical diagnostic ultrasound . Sections 21.1 and 21.2 dealt with physics, instrumentation, artifacts and safety. This section is the clinical protocol.
1. Transducer Selection: The Governing Trade-off
Higher frequency gives better axial resolution but poorer penetration , because attenuation increases with frequency. Choose the highest frequency that still reaches the target depth.
- Transducer Typical frequency Footprint and beam Principal uses
- Curvilinear (convex) 2-5 MHz Wide, diverging sector at depth Abdomen, obstetrics, general survey
Linear array 7-15 MHz Rectangular, high resolution, shallow Thyroid, breast, testis, musculoskeletal, vascular access, superficial soft tissue
Phased array (sector) 2-5 MHz Small footprint, wide sector Cardiac — fits between the ribs; also transcranial
Endocavitary (transvaginal / transrectal) 5-9 MHz High resolution at short range Early pregnancy, gynaecological pelvis, prostate
- Microconvex 5-8 MHz Small footprint Neonatal head through the fontanelle, paediatric abdomen
- 2. Preparation by Examination — The Highest-Yield Table
Examination Preparation Why
Upper abdomen / hepatobiliary / gallbladder Fast 6-8 hours (water permitted in some protocols) A fasted gallbladder is distended and assessable; fasting reduces bowel gas
Renal / urinary tract Moderately full bladder; no fasting strictly required Distended bladder allows assessment of wall, jets and post-void residual
Transabdominal pelvis (gynaecological) Full bladder — 4-6 glasses of water about an hour before, do not void The bladder is an acoustic window that displaces bowel and lifts the uterus
- Transvaginal pelvis Empty bladder A full bladder pushes the pelvic organs out of the near field
- Obstetric first trimester Full bladder if transabdominal; empty if transvaginal Same acoustic-window logic
- Obstetric second and third trimester No preparation Amniotic fluid is its own window
- Thyroid / neck None; neck extended with a pillow under the shoulders Access to the lower poles
- Breast None; no deodorant or lotion is required for ultrasound Direct contact scanning
Scrotal / testicular None; scrotum supported on a towel between the thighs, penis retracted and covered Stabilises the target
Musculoskeletal None Dynamic scanning during movement is often diagnostic
Vascular / carotid / venous duplex None; avoid heavy meals before mesenteric studies Bowel gas obscures deep vessels
Echocardiography None —
Neonatal cranial None; scan through the anterior fontanelle The fontanelle is the acoustic window and closes by 12-18 months
Interventional guidance (biopsy, drainage, cannulation) Coagulation status checked; sterile probe cover and sterile gel Aseptic technique is mandatory
The single most examined pairing: transabdominal pelvic scanning requires a full bladder; transvaginal scanning requires an empty bladder.
- 3. Protocols by Region
- Hepatobiliary and upper abdomen
Liver: longitudinal and transverse sweeps through both lobes; subcostal, intercostal and epigastric approaches; document the right and left lobes, portal and hepatic veins, and the hepatic echotexture. Normal liver is slightly more echogenic than the renal cortex .
Gallbladder: long axis and transverse, supine and left lateral decubitus to demonstrate mobility of a calculus. A stone is echogenic, casts a clean posterior acoustic shadow , and moves with gravity; a polyp is echogenic, non-shadowing and non-mobile. Wall thickness above about 3 mm is abnormal. The sonographic Murphy sign — maximal tenderness with the probe directly over the gallbladder — supports acute cholecystitis.
Biliary tree: common bile duct measured at the porta hepatis; normal diameter is about 6 mm , allowing roughly 1 mm per decade over 60 years and a larger calibre post-cholecystectomy.
Pancreas: transverse epigastric with the splenic vein as the posterior landmark; water loading may improve the window.
Spleen: left intercostal coronal; normal length up to about 12 cm.
Aorta: longitudinal and transverse from the diaphragm to the bifurcation; measure outer wall to outer wall ; the upper limit of normal is about 3 cm .
Renal and urinary
Longitudinal and transverse of each kidney with the patient supine and in the decubitus positions. Document length (normal about 9-12 cm), cortical thickness, corticomedullary differentiation and the collecting system. Normal renal cortex is less echogenic than liver and spleen . Bladder volume and post-void residual are calculated from three orthogonal measurements. Hydronephrosis is graded by the degree of pelvicalyceal dilatation and cortical thinning.
Obstetric
First trimester: confirm intrauterine location, number, cardiac activity, and date by crown-rump length , which is the most accurate dating measurement. The gestational sac is visible transvaginally at about 5 weeks and the yolk sac shortly after.
Second and third trimester: biometry — biparietal diameter, head circumference, abdominal circumference, femur length — plus fetal anatomy survey, placental location and grade, amniotic fluid assessment, and umbilical artery Doppler where indicated.
Always confirm fetal cardiac activity and document it; and always check for placenta praevia in relation to the internal os.
Gynaecological
Uterine size, position, endometrial thickness and echotexture; both ovaries with follicle assessment; free fluid in the pouch of Douglas. Endometrial thickness varies with the cycle, so record the last menstrual period.
Thyroid and neck
Both lobes and the isthmus in transverse and longitudinal planes; document nodule size in three dimensions, composition, echogenicity, margins, and the presence of microcalcifications; survey the cervical nodal levels.
Scrotal
Both testes in transverse and longitudinal planes, plus a transverse image including both testes on one frame for direct comparison of size and echogenicity. Colour and spectral Doppler are mandatory — absent intratesticular flow in an acutely painful testis is torsion and is a surgical emergency. Epididymal head, body and tail; document any hydrocoele or varicocoele, the latter with a Valsalva manoeuvre.
Focused Assessment with Sonography for Trauma (FAST)
Four windows, looking for free fluid :
Right upper quadrant — hepatorenal recess (Morison pouch), the most dependent space in the supine patient and the commonest site of a positive finding.
Left upper quadrant — splenorenal recess and left subphrenic space.
Pelvis — retrovesical or rectouterine pouch.
Subxiphoid — pericardium, for tamponade.
The extended FAST (eFAST) adds bilateral anterior chest windows for pneumothorax , identified by absence of lung sliding and a stratosphere or barcode sign on M-mode.
Vascular
Carotid duplex documents intima-media thickness, plaque and peak systolic velocities in the common, internal and external carotid arteries and the vertebral artery. Lower-limb venous duplex tests compressibility at defined levels — a non-compressible vein is the primary sign of deep vein thrombosis — with augmentation and colour Doppler as adjuncts.
4. Optimising the Image While Scanning
- Control Effect
- Depth Set so the region of interest fills the image; excess depth wastes resolution and lowers frame rate
Focal zone Place at or just below the region of interest; multiple zones improve lateral resolution but lower frame rate
Overall gain Uniform brightness; too high creates noise, too low loses low-level echoes
Time gain compensation (TGC) Compensates for attenuation with depth so a uniform organ appears uniformly bright top to bottom
- Frequency Highest that still penetrates
- Harmonic imaging Reduces near-field reverberation and clutter, especially in larger patients
- Compound imaging Reduces speckle and improves margin definition
- Doppler angle Keep at or below about 60 degrees to the flow direction; velocities become unreliable above that
- Pulse repetition frequency / scale Raise for high velocities to prevent aliasing; lower for slow flow
- 5. Patient Care During the Examination
Explain the procedure and obtain consent; warm the gel where possible; drape for dignity and expose only the region being scanned; offer a chaperone for transvaginal, transrectal, breast and scrotal examinations and document the offer; scan with the patient positioned comfortably and safely; clean the transducer between patients according to the disinfection level required — high-level disinfection and a single-use cover for endocavitary probes ; and remove gel and assist the patient afterwards.
Scope note. In Philippine practice, sonographic interpretation is a medical act. The radiologic technologist performs the examination, produces and documents the required images and measurements, and reports technical observations — but does not issue a diagnosis to the patient.