Study guide

6.3 Radiographic Film Analysis: Processing Faults, Handling Artifacts & Corrective Measures

Philippine Radiologic Technologists Licensure Examination Exam

Track your progress as you read

Finished sections get a check mark.

1 Subject 1, Chapter 1: Physics of Radiology & X-Ray Production

1.1 Atomic Structure, Electromagnetic Spectrum & X-Ray Production Mechanisms 1.2 X-Ray Tube Components, Target Interactions & Emission Spectrum 1.3 Photon Interactions with Matter: Photoelectric, Compton, Coherent & Pair Production

2 Subject 1, Chapter 2: Radiographic Equipment & Circuitry

2.1 High-Voltage Generators, Transformers & Rectification Circuits 2.2 Automatic Exposure Control (AEC), Beam Restriction & Quality Control 2.3 Tube Rating Charts, Extending Tube Life, Mechanical Malfunction & Preventive Maintenance

3 Subject 1, Chapter 3: Radiobiology & Cellular Response

3.1 Radiation Interaction with Tissue, Direct/Indirect Action & LET/RBE 3.2 Law of Bergonie & Tribondeau, Deterministic vs. Stochastic Effects 3.3 Dose-Response Relationships, Embryo and Fetal Effects & Acute Radiation Syndrome

4 Subject 1, Chapter 4: Radiation Protection & Dose Limits

4.1 ALARA Principles, Structural Shielding & Dose Limits 4.2 Personnel Dosimetry & Patient Dose Reduction Techniques 4.3 Dose Calculation Problems: Time, Distance, Shielding & Structural Barrier Design

5 Subject 1, Chapter 5: Imaging Informatics & Quality Assurance

5.1 PACS Architecture, DICOM Standards & HL7 Integration 5.2 Quality Assurance & Quality Control Protocols in Diagnostic Radiography 5.3 Radiology Workflow, RIS/HIS Integration, Teleradiology & Informatics Quality Assurance

6 Subject 2, Chapter 6: Film-Screen Radiography & Sensitometry

6.1 Film Emulsion, Latent Image Formation & Darkroom Chemistry 6.2 Sensitometric Curve (H&D Curve), Film Speed & Contrast Characteristics 6.3 Radiographic Film Analysis: Processing Faults, Handling Artifacts & Corrective Measures

7 Subject 2, Chapter 7: Technical Factors & Radiographic Quality

7.1 Density/Brightness, Contrast, Spatial Resolution & Distortion Controls 7.2 Exposure Math: Inverse Square Law, 15% Rule & Grid Conversion Factors 7.3 Technique Compensation: Age, Pathology, Cast and Orthopaedic Devices, Screen Speed & Beam Restriction

8 Subject 2, Chapter 8: Computed Radiography (CR)

8.1 Photostimulable Phosphor (PSP) Plates & CR Reader Mechanics 8.2 Image Processing, CR Artifacts & Erasure Protocols

9 Subject 2, Chapter 9: Digital Radiography (DR)

9.1 Flat-Panel Detectors: Direct vs. Indirect Conversion & TFT Arrays 9.2 Detective Quantum Efficiency (DQE), Modulation Transfer Function (MTF) & Dynamic Range

10 Subject 2, Chapter 10: Exposure Indicators & Image Evaluation

10.1 Exposure Indicators (S-Number, EI, DI), Windowing & Look-Up Tables (LUT) 10.2 Image Critique Checklist, Artifact Identification & Quality Control Standards 10.3 Image Display & Hard-Copy Output: Monitor Classification, DICOM GSDF, Dry vs Wet Laser Imaging

11 Subject 3, Chapter 11: Chest, Abdomen & Routine Positioning Concepts

11.1 Anatomical Terminology, Body Planes & Chest Radiography (PA, Lateral, Decubitus) 11.2 Abdominal Radiography: Acute Abdomen Series & Erect/Supine Protocols 11.3 Radiologic Surface Anatomy, Body Habitus & Sectional Body Cuts

12 Subject 3, Chapter 12: Upper & Lower Extremities & Girdles

12.1 Upper Limb & Shoulder Girdle Positioning (Hand, Wrist, Forearm, Elbow, Humerus, Shoulder) 12.2 Lower Limb & Pelvic Girdle Positioning (Foot, Ankle, Leg, Knee, Femur, Pelvis, Hip)

13 Subject 3, Chapter 13: Spine & Bony Thorax

13.1 Cervical, Thoracic & Lumbar Spine Radiography & Trauma Adaptations 13.2 Sacrum, Coccyx, Sacroiliac Joints & Bony Thorax (Ribs & Sternum)

14 Subject 3, Chapter 14: Cranium, Facial Bones & Paranasal Sinuses

14.1 Skull Positioning: Towne, Caldwell, Lateral & SMV Projections 14.2 Facial Bones, Orbits, Zygomatic Arches & Paranasal Sinuses

15 Subject 3, Chapter 15: Contrast Media Studies & Special Procedures

15.1 Gastrointestinal Contrast Procedures (Esophagram, UGI, Small Bowel, Barium Enema) 15.2 Genitourinary, Biliary & Special Fluoroscopic Studies (IVU, Cystography, ERCP, Myelography) 15.3 Reproductive System Studies: Hysterosalpingography, Pelvimetry & Male Reproductive Procedures 15.4 Nasopharyngography, Sialography & Fistulography / Sinus Tract Visualization

16 Subject 4, Chapter 16: Human Anatomy, Physiology & Pathology Integration

16.1 Body System Anatomy & Systemic Physiology Overview for Radiographers 16.2 Radiologic Pathology: Image Manifestations of Neoplastic, Inflammatory & Traumatic Conditions

17 Subject 4, Chapter 17: Patient Assessment, Communication & Informed Consent

17.1 Professional Communication, History Taking & Patient Rights 17.2 Informed Consent, Medical Documentation & Patient Transfer Safety

18 Subject 4, Chapter 18: Infection Control & Vital Signs Monitoring

18.1 Standard Precautions, Asepsis, Sterilization & Isolation Protocols 18.2 Measurement & Assessment of Vital Signs (BP, Pulse, Respiration, Temperature)

19 Subject 4, Chapter 19: Emergency Care & Aseptic Venipuncture

19.1 Basic Life Support (BLS), CPR Concepts & Emergency Response in Radiology 19.2 Aseptic Venipuncture Technique, IV Maintenance & Extravasation Care

20 Subject 4, Chapter 20: Professional Ethics, Jurisprudence & RA 7431

20.1 Republic Act No. 7431 (Radiologic Technology Act of 1992) & Board Rules 20.2 Code of Professional Ethics, Legal Liabilities, Malpractice & Negligence 20.3 Bioethical Principles in Practice, Professional Virtues & Interprofessional Relationships

21 Subject 5, Chapter 21: Diagnostic Ultrasonography

21.1 Ultrasound Physics, Transducer Construction & Doppler Principles 21.2 Acoustic Artifacts, Clinical Applications & Safety (TI/MI) 21.3 Clinical Ultrasound Examinations: Indications, Patient Preparation, Scanning Protocols & Transducer Selection

22 Subject 5, Chapter 22: Computed Tomography (CT)

22.1 CT Physics, Gantry Components, Detectors & Helical/Multislice Acquisition 22.2 Hounsfield Units, Windowing, CT Artifacts & Radiation Dose (CTDI/DLP)

23 Subject 5, Chapter 23: Magnetic Resonance Imaging (MRI)

23.1 MRI Physics, Nuclear Spin, T1/T2 Relaxation & Pulse Sequences 23.2 MRI Safety (Zones I-IV, SAR, Metallic Implants) & Common Artifacts 23.3 MRI Examination Protocols, Patient Preparation, Gadolinium Contrast & Sectional MRI Anatomy

24 Subject 5, Chapter 24: Interventional Radiology & Vascular Imaging

24.1 Vascular Access, Seldinger Technique & Digital Subtraction Angiography (DSA) 24.2 Interventional Procedures (Embolization, Angioplasty, Stenting) & C-Arm Radiation Safety 24.3 Interventional Patient Management: Contrast Selection, Pre-Procedure Workup & Post-Procedure Care

25 Subject 5, Chapter 25: Contrast Media Pharmacology & Adverse Reactions

25.1 Classification of Contrast Agents: Osmolality, Viscosity & Iodine Concentration 25.2 Adverse Contrast Reactions (Mild, Moderate, Severe) & Emergency Treatment Protocols 25.3 General Pharmacologic Principles: Pharmacokinetics, Pharmacodynamics, Drug Categories & the Rights of Drug Safety

26 Subject 5, Chapter 26: Nuclear Medicine & Molecular Imaging

26.1 Radioisotopes, Radiopharmaceuticals & Gamma Camera / SPECT Operation 26.2 Positron Emission Tomography (PET/CT) & Unsealed Radiation Source Safety

27 Subject 5, Chapter 27: Radiation Therapy & Radiation Oncology

27.1 Principles of Radiation Oncology, Linear Accelerators & Treatment Planning 27.2 Teletherapy vs. Brachytherapy, Patient Immobilization & Side Effect Management 27.3 Isodose Planning, Treatment Delivery Methods & Radiobiologic Principles in Radiation Therapy

28 Mammography & Dental Radiography

28.1 Mammography: Equipment, CC and MLO Positioning, Compression & Breast Pathology 28.2 Dental Radiography: Paralleling and Bisecting Techniques, Bitewing, Occlusal, Panoramic & Cephalometric

29 Medical Terminology for Radiologic Technology

29.1 Medical Word Building: Root Words, Combining Forms, Prefixes & Suffixes 29.2 Medical Terms in General Medicine, Abbreviations, Symbols & Critiquing Requests and Reports

30 Radiology Administration, Organization & Leadership

30.1 Organizational Structure, Staffing & Licensing Requirements of a Radiology Facility 30.2 Radiology Department Management: Job Descriptions, Duties, Leadership Styles & Entrepreneurial Skills

6.3 Radiographic Film Analysis: Processing Faults, Handling Artifacts & Corrective Measures

Key Takeaways Explain This Topic AI

Film faults divide into three families by cause: exposure faults (density and contrast errors), processing faults (chemical, temperature, time and replenishment errors), and handling or storage faults (pressure, static, light, chemical and mechanical marks).

Underdeveloped films are light with low contrast and a milky or brownish base, most often from developer temperature below 35 degrees Celsius, exhausted or under-replenished developer, or shortened immersion time.

Inadequate fixing leaves residual silver halide, so the film looks milky when fresh and turns brown or yellow over weeks — the classic sign that fixer was exhausted or wash was insufficient.

Static artifacts appear as tree, crown or smudge patterns from low humidity and rapid film handling, whereas pressure and crinkle marks are crescent-shaped and come from bending the film before exposure.

The correct workflow for any fault is to identify the pattern, classify it as exposure, processing or handling, verify with a sensitometric strip and processor quality-control chart, then apply the specific corrective measure and re-check rather than simply repeating the exposure.

Last updated: August 2026

6.3 Radiographic Film Analysis: Processing Faults, Handling Artifacts & Corrective Measures

The Enhanced TOS gives Radiographic Film Analysis 7 items with three competencies: point out the causes of processing faults with their technical and procedural factors and possible remedies , identify problems of inadequate processing , and execute corrective measures to detected problems . Film-screen imaging remains in the blueprint because a great many Philippine facilities — particularly rural health units, municipal hospitals and mobile screening services — still run analogue systems, and because the underlying diagnostic logic transfers directly to digital artifact analysis.

1. A Systematic Method

Never jump straight to "repeat the exposure." Work the fault in four steps.

Describe the appearance precisely. Is the whole film affected or only part of it? Is it too dark or too light? Is the pattern geometric, branching, crescentic, linear, or blotchy?

Classify the family.

Exposure fault — the whole image is uniformly too dark or too light with normal base and normal drying.

Processing fault — density and contrast are wrong and the film looks chemically abnormal (milky, brown, streaked, tacky, or wet).

Handling or storage fault — a discrete pattern superimposed on an otherwise acceptable image.

Verify objectively. Run a sensitometric strip : a light film with reduced contrast and a low speed index confirms a developer problem, whereas a normal strip on a light radiograph points back to exposure factors. Check the processor quality-control chart for drifting speed, contrast and base-plus-fog values.

Apply and document the corrective measure , then re-check.

2. Density and Contrast Faults from Exposure

Appearance Cause Remedy

Uniformly too dark (overexposed) mAs too high; kVp too high; SID too short; grid omitted when required Reduce mAs; verify SID; use the density-maintenance and grid conversion formulas

Uniformly too light (underexposed) mAs too low; kVp too low; SID too long; AEC detector not covered by the anatomy Recalculate with the 15% rule or mAs adjustment; verify AEC chamber selection

Low contrast, grey overall kVp too high; excessive scatter; no grid; fogged film Lower kVp and raise mAs; collimate; use an appropriate grid; check film storage

  • Excessive contrast kVp too low for the part Raise kVp and reduce mAs proportionally
  • 3. Processing Faults
  • Underdevelopment

Appearance: light image, reduced contrast , sometimes a milky or brownish cast. Causes: developer temperature below the operating point (typically about 35 degrees Celsius for 90-second automatic processing); exhausted or oxidised developer; inadequate replenishment; immersion time too short; developer diluted with water or contaminated with fixer. Remedies: verify and correct developer temperature; check replenishment rate against film throughput; replace exhausted chemistry; confirm the transport speed; never top up developer with water.

Overdevelopment

Appearance: dark image with increased base-plus-fog and reduced contrast. Causes: developer temperature too high; over-replenishment; excessive immersion time; developer concentration too strong. Remedies: correct temperature and replenishment; check the mixing ratio.

Inadequate fixing

Appearance: the film looks milky, cloudy or opalescent when fresh, and turns brown or yellow over weeks to months . Cause: exhausted fixer, insufficient fixing time, or fixer diluted or contaminated. Residual undeveloped silver halide is never cleared. Remedy: replace the fixer; verify fixing time and replenishment; this is the classic archival quality failure and is why old films in a records room discolour.

Inadequate washing

Appearance: film turns brown or yellow over time and feels sticky. Cause: residual thiosulphate (hypo) from the fixer is not washed out. Remedy: check wash water flow and temperature; residual hypo testing is a formal archival-quality quality-control test.

Transport and mechanical faults

Appearance Cause Remedy

Guide-shoe marks — evenly spaced fine lines running parallel to the direction of travel , usually near the leading or trailing edge Misaligned or dirty guide shoes in the turnaround assembly Clean and realign the guide shoes

Pi lines — lines perpendicular to the direction of travel, spaced about 3.1 cm apart A dirty or roughened roller; the spacing equals pi times the roller diameter Clean the rollers

Wet, tacky or incompletely dried film Dryer temperature too low; exhausted or contaminated fixer preventing hardening; excessive humidity Correct dryer temperature; replace fixer

Chemical fog (uniform grey) Contaminated developer; excessive developer temperature; safelight fault Replace chemistry; perform a safelight fog test

Streaking, uneven density bands Inadequate agitation, dirty crossover racks, dried chemistry deposits Clean racks; perform scheduled processor maintenance

4. Handling and Storage Artifacts

Artifact Appearance Cause Prevention

Static — tree, crown, smudge Branching, spiked, or blotchy black marks Low humidity plus friction from rapid removal of film from the box or cassette Maintain relative humidity 30-60% ; handle film slowly; anti-static cleaning

Pressure / crinkle mark Crescent-shaped black or white mark Bending the film with a fingernail; forcing film into a cassette. Crescent before exposure is often light-toned; after exposure it is dark Handle by the edges; do not bend

Fingerprints Sharp positive or negative fingerprint outlines Oily or chemically contaminated fingers Wash and dry hands; handle by edges

Light fog Overall or edge-pattern darkening, loss of contrast Cassette light leak; darkroom light leak; safelight too bright, wrong filter, wrong wattage, or mounted too close Perform a darkroom fog test ; verify safelight filter type, bulb wattage and a mounting distance of at least about 1.2 m

Radiation fog Overall darkening Storage near a radiation source Store film in a shielded area away from x-ray rooms

Age fog Grey, low-contrast film Film used past its expiry date Rotate stock; use first in, first out

Heat and humidity fog Overall fog and mottle Storage above the recommended temperature or humidity Store at roughly 10-21 degrees Celsius and 30-60% relative humidity

Screen artifacts Repeating white spots or lines in the same position on every film from one cassette Dirt, hair or damage on the intensifying screen Clean screens with the manufacturer's solution; log and retire damaged cassettes

Poor film-screen contact Localised blurring in one region on every film from a cassette Warped cassette, damaged foam, trapped debris Perform the wire-mesh test ; repair or retire the cassette

5. Confirming with Sensitometry and Processor Quality Control

A sensitometer exposes a calibrated step wedge onto film; a densitometer reads the resulting optical densities. Three numbers are charted daily:

Index What it means Typical action limit

Base plus fog Density of the unexposed processed film Investigate above about 0.25 ; rising values indicate fog or chemical contamination

Speed index (mid-density step) Sensitivity of the system Investigate beyond about plus or minus 0.10-0.15 density from the established operating level

Contrast index (density difference) Slope of the characteristic curve Investigate beyond about plus or minus 0.10-0.15

How to read the pattern:

Speed down , contrast down , base-plus-fog normal → underdevelopment (temperature, time or exhausted developer).

Speed up , contrast down , base-plus-fog up → overdevelopment or fog .

All three normal but the radiograph is light → the fault is exposure , not the processor. Look at the console, the AEC, or the patient.

This one table converts "the films look bad today" into a specific, actionable diagnosis, and it is exactly the analytical reasoning the Board is testing.

6. Transferring the Skill to Digital

The blueprint retains film analysis, but the same taxonomy governs digital work. Uniform density errors become exposure indicator deviations; chemical fog becomes detector offset and gain calibration error; guide-shoe and pi lines become CR reader drum, roller and light-guide artifacts as well as DR detector line-drop artifacts ; static becomes electronic noise ; poor film-screen contact becomes detector element (dead pixel) mapping ; and residual latent image on a PSP plate becomes the ghosting artifact remedied by proper erasure. The habit of classifying before repeating is what carries over.