Study guide

24.1 Vascular Access, Seldinger Technique & Digital Subtraction Angiography (DSA)

Philippine Radiologic Technologists Licensure Examination Exam

Track your progress as you read

Finished sections get a check mark.

1 Subject 1, Chapter 1: Physics of Radiology & X-Ray Production

1.1 Atomic Structure, Electromagnetic Spectrum & X-Ray Production Mechanisms 1.2 X-Ray Tube Components, Target Interactions & Emission Spectrum 1.3 Photon Interactions with Matter: Photoelectric, Compton, Coherent & Pair Production

2 Subject 1, Chapter 2: Radiographic Equipment & Circuitry

2.1 High-Voltage Generators, Transformers & Rectification Circuits 2.2 Automatic Exposure Control (AEC), Beam Restriction & Quality Control 2.3 Tube Rating Charts, Extending Tube Life, Mechanical Malfunction & Preventive Maintenance

3 Subject 1, Chapter 3: Radiobiology & Cellular Response

3.1 Radiation Interaction with Tissue, Direct/Indirect Action & LET/RBE 3.2 Law of Bergonie & Tribondeau, Deterministic vs. Stochastic Effects 3.3 Dose-Response Relationships, Embryo and Fetal Effects & Acute Radiation Syndrome

4 Subject 1, Chapter 4: Radiation Protection & Dose Limits

4.1 ALARA Principles, Structural Shielding & Dose Limits 4.2 Personnel Dosimetry & Patient Dose Reduction Techniques 4.3 Dose Calculation Problems: Time, Distance, Shielding & Structural Barrier Design

5 Subject 1, Chapter 5: Imaging Informatics & Quality Assurance

5.1 PACS Architecture, DICOM Standards & HL7 Integration 5.2 Quality Assurance & Quality Control Protocols in Diagnostic Radiography 5.3 Radiology Workflow, RIS/HIS Integration, Teleradiology & Informatics Quality Assurance

6 Subject 2, Chapter 6: Film-Screen Radiography & Sensitometry

6.1 Film Emulsion, Latent Image Formation & Darkroom Chemistry 6.2 Sensitometric Curve (H&D Curve), Film Speed & Contrast Characteristics 6.3 Radiographic Film Analysis: Processing Faults, Handling Artifacts & Corrective Measures

7 Subject 2, Chapter 7: Technical Factors & Radiographic Quality

7.1 Density/Brightness, Contrast, Spatial Resolution & Distortion Controls 7.2 Exposure Math: Inverse Square Law, 15% Rule & Grid Conversion Factors 7.3 Technique Compensation: Age, Pathology, Cast and Orthopaedic Devices, Screen Speed & Beam Restriction

8 Subject 2, Chapter 8: Computed Radiography (CR)

8.1 Photostimulable Phosphor (PSP) Plates & CR Reader Mechanics 8.2 Image Processing, CR Artifacts & Erasure Protocols

9 Subject 2, Chapter 9: Digital Radiography (DR)

9.1 Flat-Panel Detectors: Direct vs. Indirect Conversion & TFT Arrays 9.2 Detective Quantum Efficiency (DQE), Modulation Transfer Function (MTF) & Dynamic Range

10 Subject 2, Chapter 10: Exposure Indicators & Image Evaluation

10.1 Exposure Indicators (S-Number, EI, DI), Windowing & Look-Up Tables (LUT) 10.2 Image Critique Checklist, Artifact Identification & Quality Control Standards 10.3 Image Display & Hard-Copy Output: Monitor Classification, DICOM GSDF, Dry vs Wet Laser Imaging

11 Subject 3, Chapter 11: Chest, Abdomen & Routine Positioning Concepts

11.1 Anatomical Terminology, Body Planes & Chest Radiography (PA, Lateral, Decubitus) 11.2 Abdominal Radiography: Acute Abdomen Series & Erect/Supine Protocols 11.3 Radiologic Surface Anatomy, Body Habitus & Sectional Body Cuts

12 Subject 3, Chapter 12: Upper & Lower Extremities & Girdles

12.1 Upper Limb & Shoulder Girdle Positioning (Hand, Wrist, Forearm, Elbow, Humerus, Shoulder) 12.2 Lower Limb & Pelvic Girdle Positioning (Foot, Ankle, Leg, Knee, Femur, Pelvis, Hip)

13 Subject 3, Chapter 13: Spine & Bony Thorax

13.1 Cervical, Thoracic & Lumbar Spine Radiography & Trauma Adaptations 13.2 Sacrum, Coccyx, Sacroiliac Joints & Bony Thorax (Ribs & Sternum)

14 Subject 3, Chapter 14: Cranium, Facial Bones & Paranasal Sinuses

14.1 Skull Positioning: Towne, Caldwell, Lateral & SMV Projections 14.2 Facial Bones, Orbits, Zygomatic Arches & Paranasal Sinuses

15 Subject 3, Chapter 15: Contrast Media Studies & Special Procedures

15.1 Gastrointestinal Contrast Procedures (Esophagram, UGI, Small Bowel, Barium Enema) 15.2 Genitourinary, Biliary & Special Fluoroscopic Studies (IVU, Cystography, ERCP, Myelography) 15.3 Reproductive System Studies: Hysterosalpingography, Pelvimetry & Male Reproductive Procedures 15.4 Nasopharyngography, Sialography & Fistulography / Sinus Tract Visualization

16 Subject 4, Chapter 16: Human Anatomy, Physiology & Pathology Integration

16.1 Body System Anatomy & Systemic Physiology Overview for Radiographers 16.2 Radiologic Pathology: Image Manifestations of Neoplastic, Inflammatory & Traumatic Conditions

17 Subject 4, Chapter 17: Patient Assessment, Communication & Informed Consent

17.1 Professional Communication, History Taking & Patient Rights 17.2 Informed Consent, Medical Documentation & Patient Transfer Safety

18 Subject 4, Chapter 18: Infection Control & Vital Signs Monitoring

18.1 Standard Precautions, Asepsis, Sterilization & Isolation Protocols 18.2 Measurement & Assessment of Vital Signs (BP, Pulse, Respiration, Temperature)

19 Subject 4, Chapter 19: Emergency Care & Aseptic Venipuncture

19.1 Basic Life Support (BLS), CPR Concepts & Emergency Response in Radiology 19.2 Aseptic Venipuncture Technique, IV Maintenance & Extravasation Care

20 Subject 4, Chapter 20: Professional Ethics, Jurisprudence & RA 7431

20.1 Republic Act No. 7431 (Radiologic Technology Act of 1992) & Board Rules 20.2 Code of Professional Ethics, Legal Liabilities, Malpractice & Negligence 20.3 Bioethical Principles in Practice, Professional Virtues & Interprofessional Relationships

21 Subject 5, Chapter 21: Diagnostic Ultrasonography

21.1 Ultrasound Physics, Transducer Construction & Doppler Principles 21.2 Acoustic Artifacts, Clinical Applications & Safety (TI/MI) 21.3 Clinical Ultrasound Examinations: Indications, Patient Preparation, Scanning Protocols & Transducer Selection

22 Subject 5, Chapter 22: Computed Tomography (CT)

22.1 CT Physics, Gantry Components, Detectors & Helical/Multislice Acquisition 22.2 Hounsfield Units, Windowing, CT Artifacts & Radiation Dose (CTDI/DLP)

23 Subject 5, Chapter 23: Magnetic Resonance Imaging (MRI)

23.1 MRI Physics, Nuclear Spin, T1/T2 Relaxation & Pulse Sequences 23.2 MRI Safety (Zones I-IV, SAR, Metallic Implants) & Common Artifacts 23.3 MRI Examination Protocols, Patient Preparation, Gadolinium Contrast & Sectional MRI Anatomy

24 Subject 5, Chapter 24: Interventional Radiology & Vascular Imaging

24.1 Vascular Access, Seldinger Technique & Digital Subtraction Angiography (DSA) 24.2 Interventional Procedures (Embolization, Angioplasty, Stenting) & C-Arm Radiation Safety 24.3 Interventional Patient Management: Contrast Selection, Pre-Procedure Workup & Post-Procedure Care

25 Subject 5, Chapter 25: Contrast Media Pharmacology & Adverse Reactions

25.1 Classification of Contrast Agents: Osmolality, Viscosity & Iodine Concentration 25.2 Adverse Contrast Reactions (Mild, Moderate, Severe) & Emergency Treatment Protocols 25.3 General Pharmacologic Principles: Pharmacokinetics, Pharmacodynamics, Drug Categories & the Rights of Drug Safety

26 Subject 5, Chapter 26: Nuclear Medicine & Molecular Imaging

26.1 Radioisotopes, Radiopharmaceuticals & Gamma Camera / SPECT Operation 26.2 Positron Emission Tomography (PET/CT) & Unsealed Radiation Source Safety

27 Subject 5, Chapter 27: Radiation Therapy & Radiation Oncology

27.1 Principles of Radiation Oncology, Linear Accelerators & Treatment Planning 27.2 Teletherapy vs. Brachytherapy, Patient Immobilization & Side Effect Management 27.3 Isodose Planning, Treatment Delivery Methods & Radiobiologic Principles in Radiation Therapy

28 Mammography & Dental Radiography

28.1 Mammography: Equipment, CC and MLO Positioning, Compression & Breast Pathology 28.2 Dental Radiography: Paralleling and Bisecting Techniques, Bitewing, Occlusal, Panoramic & Cephalometric

29 Medical Terminology for Radiologic Technology

29.1 Medical Word Building: Root Words, Combining Forms, Prefixes & Suffixes 29.2 Medical Terms in General Medicine, Abbreviations, Symbols & Critiquing Requests and Reports

30 Radiology Administration, Organization & Leadership

30.1 Organizational Structure, Staffing & Licensing Requirements of a Radiology Facility 30.2 Radiology Department Management: Job Descriptions, Duties, Leadership Styles & Entrepreneurial Skills

24.1 Vascular Access, Seldinger Technique & Digital Subtraction Angiography (DSA)

Key Takeaways Explain This Topic AI

The Seldinger technique is the fundamental 6-step percutaneous vascular access method comprising vessel needle puncture, stylet removal with blood return verification, guidewire insertion, needle removal over the wire, sheath or catheter advancement over the wire, and wire/dilator removal.

The common femoral artery (CFA) is the primary access site for systemic arteriography due to its large caliber and posterior backing by the femoral head for compression, whereas transradial access (TRA) dramatically reduces access-site bleeding complications.

Angiographic catheters are sized in the French scale (1 Fr = 1/3 mm outer diameter); multi-orifice pigtail catheters disperse contrast radially for high-volume aortography, whereas shaped selective catheters (Cobra, Judkins, Simmons) engage specific vessel ostia.

Digital Subtraction Angiography (DSA) acquires a pre-contrast mask image and subtracts it pixel-by-pixel from live contrast-enhanced frames to eliminate overlapping bone and soft tissue structures.

Advanced DSA post-processing features include roadmapping, which overlays static contrast masks onto live fluoroscopy for wire navigation, and pixel shift, which translates mask coordinates to correct patient motion misregistration artifacts.

Last updated: August 2026

  • 24.1 Vascular Access, Seldinger Technique & Digital Subtraction Angiography (DSA)
  • Introduction to Interventional Vascular Access

Interventional Radiology (IR) combines high-resolution diagnostic fluoroscopy with minimally invasive therapeutic techniques. Central to diagnostic arteriography and endovascular therapy is obtaining safe, predictable, and reproducible percutaneous entry into the vascular system. The radiologic technologist (RadTech) plays a crucial operational role in sterile field preparation, vascular hardware management, monitoring automatic high-pressure injectors, and executing digital subtraction angiography (DSA) post-processing protocols.

Percutaneous Vascular Access: The Seldinger Technique

Introduced in 1953 by Swedish radiologist Sven Ivar Seldinger, the Seldinger technique revolutionized vascular intervention by replacing traumatic surgical vessel cutdowns with percutaneous needle puncture. It is the universally accepted standard method for arterial, venous, and non-vascular percutaneous lumen access.

The Standard 6-Step Percutaneous Access Protocol

Step 1: Needle Puncture of the Target Vessel An access needle (typically an 18-gauge thin-wall needle or a 21-gauge micro-puncture needle) with an internal sharp stylet is inserted through a small skin nick. The needle is angled at 30 ∘ 30^\circ 3 0 ∘ to 45 ∘ 45^\circ 4 5 ∘ relative to the skin surface and advanced directly into the anterior wall of the target blood vessel.

Step 2: Removal of Inner Stylet & Verification of Blood Return The sharp inner stylet is carefully withdrawn while maintaining the needle position. Free, brisk, pulsatile flow of bright red blood confirms proper intraluminal positioning within an artery (or steady non-pulsatile dark blood return for venous access). If blood flow is sluggish or absent, the needle tip may reside subintimally or beyond the posterior wall.

Step 3: Guidewire Insertion Through Needle A flexible, atraumatic guidewire (typically 0.035 inch 0.035\text{ inch} 0.035 inch or 0.018 inch 0.018\text{ inch} 0.018 inch diameter) is gently passed through the needle lumen into the vessel under fluoroscopic visualization. The wire must advance smoothly without any tactile resistance. Rule: Never force a guidewire against resistance, as this can cause vessel dissection, intima perforation, or arterial spasm.

Step 4: Needle Removal Over the Guidewire While keeping the guidewire firmly anchored at the skin surface to prevent accidental wire advancement or dislodgement, the puncture needle is completely withdrawn over the wire and removed from the field. The external wire is immediately wiped with a wet heparinized gauze sponge to remove dried blood clots.

Step 5: Sheath or Catheter Advancement Over Guidewire A tapered vascular sheath (fitted with an internal vessel dilator) or a diagnostic angiographic catheter is threaded over the proximal end of the guidewire. The sheath-dilator assembly is advanced through the skin track into the vessel lumen using a gentle twisting motion.

Step 6: Removal of Guidewire & Vessel Dilator Once the vascular sheath is securely positioned within the vessel, the internal dilator and guidewire are removed together, leaving the hemostatic sheath in place. The side-port valve of the sheath is aspirated to remove any air micro-bubbles or clot fragments and immediately flushed with heparinized saline solution.

Summary Table: Steps of the Standard Seldinger Technique

Step # Action Clinical Purpose Technical & Safety Considerations

Step 1 Needle Puncture Punctures anterior vessel wall at 30 ∘ – 45 ∘ 30^\circ\text{--}45^\circ 3 0 ∘ – 4 5 ∘ Angle needle with bevel up; use micro-puncture set for small or spasm-prone vessels.

Step 2 Stylet Removal Confirm true intraluminal position Observe brisk pulsatile blood return; never advance wire if flow is poor or absent.

Step 3 Guidewire Insertion Establish intravascular track Pass wire under fluoroscopy; wire must advance smoothly without tactile resistance.

Step 4 Needle Removal Clear needle while maintaining wire Anchor wire firmly at skin level; wipe wire with wet heparinized gauze to prevent clotting.

Step 5 Sheath/Catheter Entry Dilate tract & secure lumen Perform a small skin nick with a #11 scalpel; twist sheath-dilator assembly smoothly over wire.

Step 6 Wire & Dilator Removal Establish clear working lumen Aspirate side-port blood and flush immediately with heparinized saline.

  • Arterial Access Sites & Anatomical Landmarks
  • 1. Common Femoral Artery (CFA) — Primary Access Site

Anatomical Boundaries : The CFA is the direct downward continuation of the external iliac artery below the inguinal ligament. It bifurcates into the superficial femoral artery (SFA) and profunda femoris artery.

Ideal Fluoroscopic Target : The puncture site must be positioned over the inner third of the femoral head as identified on fluoroscopy.

Advantages : High vessel caliber ( 7 – 10 mm 7\text{--}10\text{ mm} 7 – 10 mm diameter), superficial depth, and firm posterior bony backing provided by the femoral head, which allows effective manual compression to achieve post-procedure hemostasis.

Puncture Hazards :

High Puncture (Above Inguinal Ligament / Femoral Head) : Enters the external iliac artery above the retroperitoneal reflection. Compression against bone is impossible, leading to occult, life-threatening retroperitoneal hemorrhage .

Low Puncture (Below CFA Bifurcation) : Puncturing the SFA or profunda femoris increases the risk of pseudoaneurysm formation , arteriovenous (AV) fistula, thrombosis, and hematoma.

2. Radial Artery — Transradial Access (TRA)

Clinical Trend : Transradial access has become the preferred approach for coronary angiography and selected peripheral interventions.

Advantages : Eliminates retroperitoneal bleeding risks, drastically lowers access-site hematoma rates, permits immediate patient post-procedure ambulation, and reduces hospital stay costs.

Prerequisite Assessment (Modified Allen Test / Barbeau Test) : Prior to radial cannulation, patency of the dual palmar arterial arch must be verified to ensure collateral blood supply to the hand via the ulnar artery if radial artery occlusion occurs. Barbeau test utilizes pulse oximetry on the thumb during radial artery compression to confirm collateral flow.

3. Brachial & Axillary Arteries — Secondary Access Sites

Utilized when severe aortoiliac occlusive disease, Leriche syndrome, or anatomical tortuosity precludes lower extremity access. Punctures carry a higher risk of median nerve injury, brachial artery thrombosis, and compartment syndrome due to smaller vessel diameter and lack of bony compression backing.

  • Angiographic Equipment & Catheters
  • 1. Guidewires

Guidewires serve as the foundational structural track over which catheters, sheath dilators, balloons, and stents are navigated.

Tip Configurations :

J-Tip ( 1.5 – 3.0 mm 1.5\text{--}3.0\text{ mm} 1.5 – 3.0 mm radius curve) : The curved J-tip deflects off vessel walls, preventing accidental subintimal dissection or intima scoring in tortuous, diseased, or aneurysmal vessels.

Straight Tip : Used for selective probing and crossing tight arterial stenoses or calcified branch origins.

Core Materials & Coatings :

Hydrophilic Polymer Coating (Glidewire) : Becomes extremely slick when hydrated with saline, reducing friction inside tortuous vessels. Must be kept continuously wet on the back table to prevent friction lock.

Nitinol (Nickel-Titanium Alloy) : Superelastic core providing maximum kink-resistance and shape memory.

Stainless Steel Core : Provides high vertical column strength and tactile pushability for delivering heavy interventional equipment.

Standard Diameters : 0.035 inch ( 0.89 mm ) 0.035\text{ inch } (0.89\text{ mm}) 0.035 inch ( 0.89 mm ) for general peripheral and visceral diagnostic imaging; 0.014 inch ( 0.36 mm ) 0.014\text{ inch } (0.36\text{ mm}) 0.014 inch ( 0.36 mm ) for microvascular, renal, and coronary interventions.

2. Vascular Sheaths

Vascular sheaths are outer protective tubes inserted into the access site to shield the arterial wall from friction trauma during repeated catheter exchanges. Key components include an integrated hemostatic valve at the hub to prevent backbleeding and a side-port channel for continuous heparinized saline infusion or direct invasive blood pressure monitoring.

3. Diagnostic Angiographic Catheters

Catheters are sized according to the French scale (Fr) , where 1 Fr = 1 3 mm 1\text{ Fr} = \frac{1}{3}\text{ mm} 1 Fr = 3 1 ​ mm outer diameter (e.g., a 6 Fr 6\text{ Fr} 6 Fr catheter has an outer diameter of 2.0 mm 2.0\text{ mm} 2.0 mm ):

Pigtail Flush Catheter : Features a circular coiled tip with multiple side-holes located proximal to the end-hole. Designed for high-volume non-selective injections (e.g., thoracic or abdominal aortography). The side-holes disperse contrast radially, preventing high-velocity fluid jets that could cause catheter recoil ("whipping") or traumatic aortic wall dissection.

Cobra Catheter (C1, C2, C3) : Angled tapered tip used for selective cannulation of visceral arteries arising from the abdominal aorta (renals, celiac trunk, superior mesenteric artery).

Judkins Left (JL) & Judkins Right (JR) : Pre-shaped specialized catheters designed for selective engagement of left and right coronary artery ostia.

Simmons / Sidewinder Catheter : Reverse-curve catheter designed for selective catheterization of branch vessels in tortuous aortic arches or acute-angled visceral take-offs.

4. Automatic High-Pressure Injectors

Automatic injectors deliver high-density non-ionic contrast media at exact flow rates and pressures beyond human hand-injection capability.

Injector Control Parameters :

Flow Rate (mL/sec) : Volume of contrast delivered per second (e.g., 20 – 25 mL/sec 20\text{--}25\text{ mL/sec} 20 – 25 mL/sec for abdominal aortography; 3 – 5 mL/sec 3\text{--}5\text{ mL/sec} 3 – 5 mL/sec for selective renal angiography).

Total Volume (mL) : Total contrast dose delivered during an injection run (e.g., 30 – 50 mL 30\text{--}50\text{ mL} 30 – 50 mL for aortography).

Pressure Limit (PSI) : Maximum allowable pounds per square inch (typically set to 800 – 1200 PSI 800\text{--}1200\text{ PSI} 800 – 1200 PSI ) to prevent catheter hub bursting or lumen rupture.

Linear Acceleration / Rise Time : Time taken to reach peak flow rate (e.g., 0.2 – 0.5 sec 0.2\text{--}0.5\text{ sec} 0.2 – 0.5 sec ); gradual acceleration prevents sudden catheter recoil.

Syringe Heating Sleeve : Warms viscous contrast to body temperature ( 37 ∘ C 37^\circ\text{C} 3 7 ∘ C ), which reduces contrast viscosity by approximately 50%, enabling higher flow rates through thin-walled diagnostic catheters.

Digital Subtraction Angiography (DSA) Principles

Digital Subtraction Angiography (DSA) is a computer-assisted fluoroscopic technique that isolates contrast-filled blood vessels by mathematically eliminating background anatomical structures (bone and soft tissue). [Pre-Contrast Mask Image] ---> (Inverted Pixel Values)

  • +
  • [Live Contrast Image] ---> [Subtracted Image] (Vessels Only)
  • The DSA Subtraction Algorithm

Mask Frame Acquisition : Prior to contrast arrival, a baseline pre-contrast radiograph (the mask frame ) is acquired under fluoroscopy. This frame contains all background skeletal, dental, and soft-tissue structures.

Contrast Injection Frames : Contrast medium is injected via an automatic injector, and serial high-resolution radiograms are recorded at frame rates of 1 – 8 frames/sec 1\text{--}8\text{ frames/sec} 1 – 8 frames/sec across arterial, capillary, and venous phases.

Mathematical Subtraction : The digital matrix values (logarithmic attenuation values) of the pre-contrast mask image are subtracted pixel-by-pixel from the live contrast-enhanced frames. Unchanged background structures equal zero density and disappear, leaving only contrast-opacified vascular lumens displayed in high contrast against a neutral background.

Advanced DSA Post-Processing Functions

Roadmap Function : A DSA image exhibiting peak vascular opacification is captured and stored as a baseline map. This image is inverted and displayed as a semi-transparent live overlay on low-dose real-time fluoroscopy. The operator can navigate microcatheters and guidewires through intricate vascular branches without administering additional contrast injections.

Pixel Shift (Re-registration) : Involuntary patient motion (respiration, swallowing, peristalsis) between mask acquisition and contrast arrival causes misregistration artifacts (unsubtracted bright or dark bone edges obscuring vessels). Pixel shift allows the technologist to manually or automatically shift the mask matrix along sub-pixel X and Y axes to realign bone boundaries and eliminate motion artifacts.

Re-Masking : Selecting a different pre-contrast frame from the acquired frame sequence closer to the contrast arrival time to eliminate motion displacement artifacts.