Study guide

23.3 MRI Examination Protocols, Patient Preparation, Gadolinium Contrast & Sectional MRI Anatomy

Philippine Radiologic Technologists Licensure Examination Exam

Track your progress as you read

Finished sections get a check mark.

1 Subject 1, Chapter 1: Physics of Radiology & X-Ray Production

1.1 Atomic Structure, Electromagnetic Spectrum & X-Ray Production Mechanisms 1.2 X-Ray Tube Components, Target Interactions & Emission Spectrum 1.3 Photon Interactions with Matter: Photoelectric, Compton, Coherent & Pair Production

2 Subject 1, Chapter 2: Radiographic Equipment & Circuitry

2.1 High-Voltage Generators, Transformers & Rectification Circuits 2.2 Automatic Exposure Control (AEC), Beam Restriction & Quality Control 2.3 Tube Rating Charts, Extending Tube Life, Mechanical Malfunction & Preventive Maintenance

3 Subject 1, Chapter 3: Radiobiology & Cellular Response

3.1 Radiation Interaction with Tissue, Direct/Indirect Action & LET/RBE 3.2 Law of Bergonie & Tribondeau, Deterministic vs. Stochastic Effects 3.3 Dose-Response Relationships, Embryo and Fetal Effects & Acute Radiation Syndrome

4 Subject 1, Chapter 4: Radiation Protection & Dose Limits

4.1 ALARA Principles, Structural Shielding & Dose Limits 4.2 Personnel Dosimetry & Patient Dose Reduction Techniques 4.3 Dose Calculation Problems: Time, Distance, Shielding & Structural Barrier Design

5 Subject 1, Chapter 5: Imaging Informatics & Quality Assurance

5.1 PACS Architecture, DICOM Standards & HL7 Integration 5.2 Quality Assurance & Quality Control Protocols in Diagnostic Radiography 5.3 Radiology Workflow, RIS/HIS Integration, Teleradiology & Informatics Quality Assurance

6 Subject 2, Chapter 6: Film-Screen Radiography & Sensitometry

6.1 Film Emulsion, Latent Image Formation & Darkroom Chemistry 6.2 Sensitometric Curve (H&D Curve), Film Speed & Contrast Characteristics 6.3 Radiographic Film Analysis: Processing Faults, Handling Artifacts & Corrective Measures

7 Subject 2, Chapter 7: Technical Factors & Radiographic Quality

7.1 Density/Brightness, Contrast, Spatial Resolution & Distortion Controls 7.2 Exposure Math: Inverse Square Law, 15% Rule & Grid Conversion Factors 7.3 Technique Compensation: Age, Pathology, Cast and Orthopaedic Devices, Screen Speed & Beam Restriction

8 Subject 2, Chapter 8: Computed Radiography (CR)

8.1 Photostimulable Phosphor (PSP) Plates & CR Reader Mechanics 8.2 Image Processing, CR Artifacts & Erasure Protocols

9 Subject 2, Chapter 9: Digital Radiography (DR)

9.1 Flat-Panel Detectors: Direct vs. Indirect Conversion & TFT Arrays 9.2 Detective Quantum Efficiency (DQE), Modulation Transfer Function (MTF) & Dynamic Range

10 Subject 2, Chapter 10: Exposure Indicators & Image Evaluation

10.1 Exposure Indicators (S-Number, EI, DI), Windowing & Look-Up Tables (LUT) 10.2 Image Critique Checklist, Artifact Identification & Quality Control Standards 10.3 Image Display & Hard-Copy Output: Monitor Classification, DICOM GSDF, Dry vs Wet Laser Imaging

11 Subject 3, Chapter 11: Chest, Abdomen & Routine Positioning Concepts

11.1 Anatomical Terminology, Body Planes & Chest Radiography (PA, Lateral, Decubitus) 11.2 Abdominal Radiography: Acute Abdomen Series & Erect/Supine Protocols 11.3 Radiologic Surface Anatomy, Body Habitus & Sectional Body Cuts

12 Subject 3, Chapter 12: Upper & Lower Extremities & Girdles

12.1 Upper Limb & Shoulder Girdle Positioning (Hand, Wrist, Forearm, Elbow, Humerus, Shoulder) 12.2 Lower Limb & Pelvic Girdle Positioning (Foot, Ankle, Leg, Knee, Femur, Pelvis, Hip)

13 Subject 3, Chapter 13: Spine & Bony Thorax

13.1 Cervical, Thoracic & Lumbar Spine Radiography & Trauma Adaptations 13.2 Sacrum, Coccyx, Sacroiliac Joints & Bony Thorax (Ribs & Sternum)

14 Subject 3, Chapter 14: Cranium, Facial Bones & Paranasal Sinuses

14.1 Skull Positioning: Towne, Caldwell, Lateral & SMV Projections 14.2 Facial Bones, Orbits, Zygomatic Arches & Paranasal Sinuses

15 Subject 3, Chapter 15: Contrast Media Studies & Special Procedures

15.1 Gastrointestinal Contrast Procedures (Esophagram, UGI, Small Bowel, Barium Enema) 15.2 Genitourinary, Biliary & Special Fluoroscopic Studies (IVU, Cystography, ERCP, Myelography) 15.3 Reproductive System Studies: Hysterosalpingography, Pelvimetry & Male Reproductive Procedures 15.4 Nasopharyngography, Sialography & Fistulography / Sinus Tract Visualization

16 Subject 4, Chapter 16: Human Anatomy, Physiology & Pathology Integration

16.1 Body System Anatomy & Systemic Physiology Overview for Radiographers 16.2 Radiologic Pathology: Image Manifestations of Neoplastic, Inflammatory & Traumatic Conditions

17 Subject 4, Chapter 17: Patient Assessment, Communication & Informed Consent

17.1 Professional Communication, History Taking & Patient Rights 17.2 Informed Consent, Medical Documentation & Patient Transfer Safety

18 Subject 4, Chapter 18: Infection Control & Vital Signs Monitoring

18.1 Standard Precautions, Asepsis, Sterilization & Isolation Protocols 18.2 Measurement & Assessment of Vital Signs (BP, Pulse, Respiration, Temperature)

19 Subject 4, Chapter 19: Emergency Care & Aseptic Venipuncture

19.1 Basic Life Support (BLS), CPR Concepts & Emergency Response in Radiology 19.2 Aseptic Venipuncture Technique, IV Maintenance & Extravasation Care

20 Subject 4, Chapter 20: Professional Ethics, Jurisprudence & RA 7431

20.1 Republic Act No. 7431 (Radiologic Technology Act of 1992) & Board Rules 20.2 Code of Professional Ethics, Legal Liabilities, Malpractice & Negligence 20.3 Bioethical Principles in Practice, Professional Virtues & Interprofessional Relationships

21 Subject 5, Chapter 21: Diagnostic Ultrasonography

21.1 Ultrasound Physics, Transducer Construction & Doppler Principles 21.2 Acoustic Artifacts, Clinical Applications & Safety (TI/MI) 21.3 Clinical Ultrasound Examinations: Indications, Patient Preparation, Scanning Protocols & Transducer Selection

22 Subject 5, Chapter 22: Computed Tomography (CT)

22.1 CT Physics, Gantry Components, Detectors & Helical/Multislice Acquisition 22.2 Hounsfield Units, Windowing, CT Artifacts & Radiation Dose (CTDI/DLP)

23 Subject 5, Chapter 23: Magnetic Resonance Imaging (MRI)

23.1 MRI Physics, Nuclear Spin, T1/T2 Relaxation & Pulse Sequences 23.2 MRI Safety (Zones I-IV, SAR, Metallic Implants) & Common Artifacts 23.3 MRI Examination Protocols, Patient Preparation, Gadolinium Contrast & Sectional MRI Anatomy

24 Subject 5, Chapter 24: Interventional Radiology & Vascular Imaging

24.1 Vascular Access, Seldinger Technique & Digital Subtraction Angiography (DSA) 24.2 Interventional Procedures (Embolization, Angioplasty, Stenting) & C-Arm Radiation Safety 24.3 Interventional Patient Management: Contrast Selection, Pre-Procedure Workup & Post-Procedure Care

25 Subject 5, Chapter 25: Contrast Media Pharmacology & Adverse Reactions

25.1 Classification of Contrast Agents: Osmolality, Viscosity & Iodine Concentration 25.2 Adverse Contrast Reactions (Mild, Moderate, Severe) & Emergency Treatment Protocols 25.3 General Pharmacologic Principles: Pharmacokinetics, Pharmacodynamics, Drug Categories & the Rights of Drug Safety

26 Subject 5, Chapter 26: Nuclear Medicine & Molecular Imaging

26.1 Radioisotopes, Radiopharmaceuticals & Gamma Camera / SPECT Operation 26.2 Positron Emission Tomography (PET/CT) & Unsealed Radiation Source Safety

27 Subject 5, Chapter 27: Radiation Therapy & Radiation Oncology

27.1 Principles of Radiation Oncology, Linear Accelerators & Treatment Planning 27.2 Teletherapy vs. Brachytherapy, Patient Immobilization & Side Effect Management 27.3 Isodose Planning, Treatment Delivery Methods & Radiobiologic Principles in Radiation Therapy

28 Mammography & Dental Radiography

28.1 Mammography: Equipment, CC and MLO Positioning, Compression & Breast Pathology 28.2 Dental Radiography: Paralleling and Bisecting Techniques, Bitewing, Occlusal, Panoramic & Cephalometric

29 Medical Terminology for Radiologic Technology

29.1 Medical Word Building: Root Words, Combining Forms, Prefixes & Suffixes 29.2 Medical Terms in General Medicine, Abbreviations, Symbols & Critiquing Requests and Reports

30 Radiology Administration, Organization & Leadership

30.1 Organizational Structure, Staffing & Licensing Requirements of a Radiology Facility 30.2 Radiology Department Management: Job Descriptions, Duties, Leadership Styles & Entrepreneurial Skills

23.3 MRI Examination Protocols, Patient Preparation, Gadolinium Contrast & Sectional MRI Anatomy

Key Takeaways Explain This Topic AI

An MRI protocol is built from a planning localiser plus a combination of T1-weighted, T2-weighted, fluid-attenuated and fat-suppressed sequences in at least two orthogonal planes, with post-contrast T1 sequences where indicated.

On T1-weighted images fat is bright and fluid is dark, on T2-weighted images fluid is bright, and on fluid-attenuated inversion recovery cerebrospinal fluid is suppressed so that periventricular lesions become conspicuous.

Gadolinium chelates shorten T1 and therefore brighten enhancing tissue on T1-weighted sequences; they carry a risk of nephrogenic systemic fibrosis in severe renal impairment, so renal function is checked before administration.

Screening before entry to Zone IV must identify cardiac pacemakers and implanted electronic devices, ferromagnetic aneurysm clips, cochlear implants, metallic ocular foreign bodies, and pregnancy, and screening applies to accompanying relatives and to any staff entering the room.

Absolute contraindications relate to devices and foreign bodies rather than to the examination itself, and every implant must be verified as MR safe, MR conditional or MR unsafe before scanning.

Last updated: August 2026

23.3 MRI Examination Protocols, Patient Preparation, Gadolinium Contrast & Sectional MRI Anatomy

Methodology and Magnetic Resonance Imaging Anatomy carries 6 items and asks the examinee to explain the MRI examination in terms of protocol, patient preparation, use of contrast agent, and limitations of examination , and to illustrate the basic magnetic resonance imaging anatomy . Section 23.1 gave the physics and Section 23.2 the safety zones and artifacts; this section is the working examination.

1. How a Protocol Is Assembled

Every MRI protocol has the same skeleton:

Localiser (scout) in three planes — a fast, low-resolution acquisition used only for planning.

A T1-weighted sequence for anatomy.

A T2-weighted sequence for pathology, because most pathology increases water content.

A fluid-suppressed or fat-suppressed sequence appropriate to the region.

At least two orthogonal planes , so that a lesion is confirmed in more than one dimension.

Post-contrast T1-weighted sequences , usually with fat suppression, when enhancement is required.

Reading the weighting

  • T1-weighted T2-weighted FLAIR STIR
  • Parameters Short TR, short TE Long TR, long TE Long TR, long TE, long TI Short TI, inversion recovery
  • Fluid (CSF, urine, bile) Dark Bright Suppressed (dark) Bright
  • Fat Bright Intermediate to bright Bright Suppressed (dark)

Best for Anatomy, fat, subacute blood, post-contrast enhancement Pathology, oedema, fluid collections Periventricular and cortical brain lesions Marrow oedema, occult fracture, soft-tissue oedema

The single most useful heuristic: T2 is the "water" sequence — pathology is usually bright on T2. T1 is the "fat and anatomy" sequence, and it is the sequence on which gadolinium enhancement is seen.

Additional sequences to recognise:

Gradient echo (GRE) and susceptibility-weighted imaging — sensitive to blood products, calcium and metal , which "bloom" as dark signal loss.

Diffusion-weighted imaging (DWI) with an apparent diffusion coefficient (ADC) map — restricted diffusion is bright on DWI and dark on ADC , the signature of acute infarction , of abscess, and of some hypercellular tumours.

MR angiography — time-of-flight or contrast-enhanced, for vessels.

MR cholangiopancreatography (MRCP) — heavily T2-weighted, so static fluid in the biliary and pancreatic ducts is bright while everything else is dark; requires fasting .

MR spectroscopy — metabolite quantification.

Functional MRI — blood-oxygen-level-dependent contrast for cortical mapping.

Representative protocols

Study Core sequences

Brain (routine) Sagittal T1; axial T2; axial FLAIR; axial DWI/ADC; axial GRE or SWI; coronal T2; post-contrast axial, coronal and sagittal T1 if indicated

Cervical or lumbar spine Sagittal T1; sagittal T2; sagittal STIR; axial T2 through the levels of interest; post-contrast T1 with fat saturation for infection, tumour or post-operative assessment

Knee Sagittal proton density and PD fat-saturated; coronal T1 and T2 fat-saturated; axial PD fat-saturated

Liver Axial in-phase and opposed-phase T1; axial T2 fat-saturated; DWI; dynamic post-contrast T1 in arterial, portal venous and delayed phases

  • MRCP Coronal and axial heavily T2-weighted thin sections plus a thick-slab radial acquisition; fast 4-6 hours
  • Pelvis / prostate High-resolution T2 in three planes; DWI with high b value; dynamic contrast-enhanced T1
  • Cardiac Cine steady-state free precession; T2 for oedema; late gadolinium enhancement for scar or fibrosis
  • 2. Patient Preparation and Screening
  • The screening questionnaire — before the patient reaches Zone III

The following must be actively asked and documented, for the patient , for any accompanying relative or carer entering the room, and for staff :

Category Examples

Cardiac and neurostimulation devices Pacemaker, implantable cardioverter-defibrillator, loop recorder, deep-brain stimulator, vagus nerve stimulator, spinal cord stimulator

Vascular implants Aneurysm clips (ferromagnetic ones are the classic hazard), coils, stents, filters, mechanical heart valves

Ear and eye Cochlear implant ; metallic ocular foreign body — a history of metal grinding or a penetrating eye injury requires orbital radiographs before scanning

  • Infusion and drug delivery Insulin pump, implanted infusion pump, medication patch containing metal foil
  • Orthopaedic and dental Plates, screws, prostheses, external fixators, orthodontic appliances

Other Shrapnel or bullet fragments, tissue expanders with metallic ports, IUD type, body piercings, tattoos with metallic pigment

Physiological Pregnancy , breastfeeding, renal function, claustrophobia, ability to lie still, weight and girth against table limits

Every device must be classified as MR Safe (no known hazard), MR Conditional (safe only under specified field strength, gradient and SAR conditions) or MR Unsafe (never enter Zone IV). "It's probably fine" is not a classification.

Immediately before the scan

Change into a gown ; remove all metal — jewellery, watches, hairpins, hearing aids, dentures with metal, removable prostheses, coins, keys, phones, credit and access cards.

Explain the noise and provide ear protection — acoustic noise regularly exceeds 100 dB.

Provide the emergency call bell and confirm the patient can operate it.

Position for comfort; support the knees and back; use the appropriate radiofrequency coil for the region.

Manage claustrophobia with explanation, prone positioning, feet-first entry, a mirror, a companion in the room (also screened), or prescribed anxiolysis.

Confirm fasting where required — MRCP and hepatobiliary or bowel-contrast studies.

Immobilise and use breath-hold or respiratory triggering for body work; motion is the dominant cause of MRI repeats.

3. Gadolinium Contrast

Mechanism. Gadolinium is strongly paramagnetic. Chelated to prevent free-ion toxicity, it shortens T1 relaxation time in tissue where it accumulates, so enhancing tissue becomes bright on T1-weighted images . It is not "seen" directly; it changes the signal of the tissue it reaches.

  • Feature Detail
  • Typical dose About 0.1 mmol per kilogram of body weight, followed by a saline flush
  • Route Intravenous, usually via a power injector for dynamic studies

Indications Tumour detection and characterisation, infection and abscess, inflammation and demyelination activity, vascular imaging, post-operative assessment, cardiac scar imaging

Adverse reactions Much less frequent than with iodinated contrast; nausea, headache, transient taste disturbance, injection-site coolness; anaphylactoid reactions are rare but possible , so emergency drugs and trained staff must be available

Nephrogenic systemic fibrosis (NSF) A rare, serious fibrosing disorder associated with gadolinium exposure in severe renal impairment . Assess renal function before administration; use the lowest necessary dose of a lower-risk agent; avoid where contraindicated

Pregnancy Gadolinium crosses the placenta; avoid unless the benefit clearly outweighs the risk

Breastfeeding Very little is excreted in milk and less is absorbed; current guidance generally permits continued breastfeeding, but follow local policy

Gadolinium retention Trace deposition in brain and bone has been documented; clinical significance is unestablished, but it reinforces using contrast only when indicated

MRI is not free of risk simply because it uses no ionising radiation. The hazards are the static field (projectile effect), gradient fields (acoustic noise and peripheral nerve stimulation), radiofrequency energy (heating, measured as specific absorption rate, and burns from conductive loops), cryogens (quench and asphyxiation risk), and contrast .

4. Limitations of MRI

Be able to state these directly, because the TOS names limitations of examination as a competency.

Limitation Consequence

Long acquisition times Motion sensitivity; poor tolerance in unwell, paediatric or claustrophobic patients; low throughput

  • Device and implant contraindications Some patients cannot be scanned at all
  • Susceptibility artifact from metal Large signal voids and distortion near prostheses; CT may be superior
  • Poor for cortical bone and calcification Both are signal-void; CT is superior for fracture detail and calcium
  • Lung parenchyma Low proton density and severe susceptibility effects; CT is the modality of choice
  • Acute haemorrhage detection in trauma Non-contrast CT remains first-line for speed and access
  • Access and cost Limited availability in many Philippine provincial settings; higher cost than CT or ultrasound
  • Claustrophobia and body habitus Bore diameter and table weight limits
  • Monitoring difficulty Only MR-conditional monitoring, infusion and anaesthetic equipment may enter Zone IV
  • 5. Basic Sectional MRI Anatomy

The technologist checks every series before releasing the patient, so the normal appearances must be recognisable.

Brain

Axial at the level of the lateral ventricles: frontal horns, caudate heads, thalami, third ventricle, internal capsule with its anterior limb, genu and posterior limb, and the occipital horns.

Axial at the midbrain: cerebral peduncles, the "Mickey Mouse" midbrain outline, quadrigeminal plate cistern, temporal lobes.

Sagittal midline: corpus callosum with rostrum, genu, body and splenium; the pituitary in the sella; the brainstem with pons and medulla; cerebellar vermis; fourth ventricle; and the cerebral aqueduct.

Coronal: hippocampi in the medial temporal lobes, lateral ventricles, and the relationship of the internal carotid arteries to the cavernous sinus.

CSF check: dark on T1, bright on T2, suppressed on FLAIR. If CSF is bright on your "FLAIR", the sequence is mislabelled or the inversion time is wrong.

Spine

Sagittal images show the vertebral bodies with fatty marrow (bright on T1), the intervertebral discs (bright on T2 when normally hydrated), the CSF-filled thecal sac, the conus medullaris ending at about L1-L2 , and the cauda equina below it. Axial images show the disc, the thecal sac, the exiting nerve roots in the neural foramina, and the facet joints.

Knee

Sagittal images show the anterior and posterior cruciate ligaments, the menisci as low-signal triangles, the patellar tendon and the articular cartilage. Coronal images show the collateral ligaments and the medial and lateral menisci. Normal ligaments and menisci are uniformly low signal ; increased internal signal reaching an articular surface indicates a tear.

Abdomen and pelvis

Recognise the liver segments, portal and hepatic veins, gallbladder and biliary tree, pancreas with the splenic vein posterior to it, kidneys with corticomedullary differentiation on T1, adrenal glands, aorta and inferior vena cava, and in the pelvis the zonal anatomy of the uterus (bright endometrium, dark junctional zone, intermediate myometrium on T2) or of the prostate (bright peripheral zone on T2, from which most carcinoma arises).