Study guide
4.1 ALARA Principles, Structural Shielding & Dose Limits
Philippine Radiologic Technologists Licensure Examination Exam
Track your progress as you read
Finished sections get a check mark.
1 Subject 1, Chapter 1: Physics of Radiology & X-Ray Production
1.1 Atomic Structure, Electromagnetic Spectrum & X-Ray Production Mechanisms 1.2 X-Ray Tube Components, Target Interactions & Emission Spectrum 1.3 Photon Interactions with Matter: Photoelectric, Compton, Coherent & Pair Production
2 Subject 1, Chapter 2: Radiographic Equipment & Circuitry
2.1 High-Voltage Generators, Transformers & Rectification Circuits 2.2 Automatic Exposure Control (AEC), Beam Restriction & Quality Control 2.3 Tube Rating Charts, Extending Tube Life, Mechanical Malfunction & Preventive Maintenance
3 Subject 1, Chapter 3: Radiobiology & Cellular Response
3.1 Radiation Interaction with Tissue, Direct/Indirect Action & LET/RBE 3.2 Law of Bergonie & Tribondeau, Deterministic vs. Stochastic Effects 3.3 Dose-Response Relationships, Embryo and Fetal Effects & Acute Radiation Syndrome
4 Subject 1, Chapter 4: Radiation Protection & Dose Limits
4.1 ALARA Principles, Structural Shielding & Dose Limits 4.2 Personnel Dosimetry & Patient Dose Reduction Techniques 4.3 Dose Calculation Problems: Time, Distance, Shielding & Structural Barrier Design
5 Subject 1, Chapter 5: Imaging Informatics & Quality Assurance
5.1 PACS Architecture, DICOM Standards & HL7 Integration 5.2 Quality Assurance & Quality Control Protocols in Diagnostic Radiography 5.3 Radiology Workflow, RIS/HIS Integration, Teleradiology & Informatics Quality Assurance
6 Subject 2, Chapter 6: Film-Screen Radiography & Sensitometry
6.1 Film Emulsion, Latent Image Formation & Darkroom Chemistry 6.2 Sensitometric Curve (H&D Curve), Film Speed & Contrast Characteristics 6.3 Radiographic Film Analysis: Processing Faults, Handling Artifacts & Corrective Measures
7 Subject 2, Chapter 7: Technical Factors & Radiographic Quality
7.1 Density/Brightness, Contrast, Spatial Resolution & Distortion Controls 7.2 Exposure Math: Inverse Square Law, 15% Rule & Grid Conversion Factors 7.3 Technique Compensation: Age, Pathology, Cast and Orthopaedic Devices, Screen Speed & Beam Restriction
8 Subject 2, Chapter 8: Computed Radiography (CR)
8.1 Photostimulable Phosphor (PSP) Plates & CR Reader Mechanics 8.2 Image Processing, CR Artifacts & Erasure Protocols
9 Subject 2, Chapter 9: Digital Radiography (DR)
9.1 Flat-Panel Detectors: Direct vs. Indirect Conversion & TFT Arrays 9.2 Detective Quantum Efficiency (DQE), Modulation Transfer Function (MTF) & Dynamic Range
10 Subject 2, Chapter 10: Exposure Indicators & Image Evaluation
10.1 Exposure Indicators (S-Number, EI, DI), Windowing & Look-Up Tables (LUT) 10.2 Image Critique Checklist, Artifact Identification & Quality Control Standards 10.3 Image Display & Hard-Copy Output: Monitor Classification, DICOM GSDF, Dry vs Wet Laser Imaging
11 Subject 3, Chapter 11: Chest, Abdomen & Routine Positioning Concepts
11.1 Anatomical Terminology, Body Planes & Chest Radiography (PA, Lateral, Decubitus) 11.2 Abdominal Radiography: Acute Abdomen Series & Erect/Supine Protocols 11.3 Radiologic Surface Anatomy, Body Habitus & Sectional Body Cuts
12 Subject 3, Chapter 12: Upper & Lower Extremities & Girdles
12.1 Upper Limb & Shoulder Girdle Positioning (Hand, Wrist, Forearm, Elbow, Humerus, Shoulder) 12.2 Lower Limb & Pelvic Girdle Positioning (Foot, Ankle, Leg, Knee, Femur, Pelvis, Hip)
13 Subject 3, Chapter 13: Spine & Bony Thorax
13.1 Cervical, Thoracic & Lumbar Spine Radiography & Trauma Adaptations 13.2 Sacrum, Coccyx, Sacroiliac Joints & Bony Thorax (Ribs & Sternum)
14 Subject 3, Chapter 14: Cranium, Facial Bones & Paranasal Sinuses
14.1 Skull Positioning: Towne, Caldwell, Lateral & SMV Projections 14.2 Facial Bones, Orbits, Zygomatic Arches & Paranasal Sinuses
15 Subject 3, Chapter 15: Contrast Media Studies & Special Procedures
15.1 Gastrointestinal Contrast Procedures (Esophagram, UGI, Small Bowel, Barium Enema) 15.2 Genitourinary, Biliary & Special Fluoroscopic Studies (IVU, Cystography, ERCP, Myelography) 15.3 Reproductive System Studies: Hysterosalpingography, Pelvimetry & Male Reproductive Procedures 15.4 Nasopharyngography, Sialography & Fistulography / Sinus Tract Visualization
16 Subject 4, Chapter 16: Human Anatomy, Physiology & Pathology Integration
16.1 Body System Anatomy & Systemic Physiology Overview for Radiographers 16.2 Radiologic Pathology: Image Manifestations of Neoplastic, Inflammatory & Traumatic Conditions
17 Subject 4, Chapter 17: Patient Assessment, Communication & Informed Consent
17.1 Professional Communication, History Taking & Patient Rights 17.2 Informed Consent, Medical Documentation & Patient Transfer Safety
18 Subject 4, Chapter 18: Infection Control & Vital Signs Monitoring
18.1 Standard Precautions, Asepsis, Sterilization & Isolation Protocols 18.2 Measurement & Assessment of Vital Signs (BP, Pulse, Respiration, Temperature)
19 Subject 4, Chapter 19: Emergency Care & Aseptic Venipuncture
19.1 Basic Life Support (BLS), CPR Concepts & Emergency Response in Radiology 19.2 Aseptic Venipuncture Technique, IV Maintenance & Extravasation Care
20 Subject 4, Chapter 20: Professional Ethics, Jurisprudence & RA 7431
20.1 Republic Act No. 7431 (Radiologic Technology Act of 1992) & Board Rules 20.2 Code of Professional Ethics, Legal Liabilities, Malpractice & Negligence 20.3 Bioethical Principles in Practice, Professional Virtues & Interprofessional Relationships
21 Subject 5, Chapter 21: Diagnostic Ultrasonography
21.1 Ultrasound Physics, Transducer Construction & Doppler Principles 21.2 Acoustic Artifacts, Clinical Applications & Safety (TI/MI) 21.3 Clinical Ultrasound Examinations: Indications, Patient Preparation, Scanning Protocols & Transducer Selection
22 Subject 5, Chapter 22: Computed Tomography (CT)
22.1 CT Physics, Gantry Components, Detectors & Helical/Multislice Acquisition 22.2 Hounsfield Units, Windowing, CT Artifacts & Radiation Dose (CTDI/DLP)
23 Subject 5, Chapter 23: Magnetic Resonance Imaging (MRI)
23.1 MRI Physics, Nuclear Spin, T1/T2 Relaxation & Pulse Sequences 23.2 MRI Safety (Zones I-IV, SAR, Metallic Implants) & Common Artifacts 23.3 MRI Examination Protocols, Patient Preparation, Gadolinium Contrast & Sectional MRI Anatomy
24 Subject 5, Chapter 24: Interventional Radiology & Vascular Imaging
24.1 Vascular Access, Seldinger Technique & Digital Subtraction Angiography (DSA) 24.2 Interventional Procedures (Embolization, Angioplasty, Stenting) & C-Arm Radiation Safety 24.3 Interventional Patient Management: Contrast Selection, Pre-Procedure Workup & Post-Procedure Care
25 Subject 5, Chapter 25: Contrast Media Pharmacology & Adverse Reactions
25.1 Classification of Contrast Agents: Osmolality, Viscosity & Iodine Concentration 25.2 Adverse Contrast Reactions (Mild, Moderate, Severe) & Emergency Treatment Protocols 25.3 General Pharmacologic Principles: Pharmacokinetics, Pharmacodynamics, Drug Categories & the Rights of Drug Safety
26 Subject 5, Chapter 26: Nuclear Medicine & Molecular Imaging
26.1 Radioisotopes, Radiopharmaceuticals & Gamma Camera / SPECT Operation 26.2 Positron Emission Tomography (PET/CT) & Unsealed Radiation Source Safety
27 Subject 5, Chapter 27: Radiation Therapy & Radiation Oncology
27.1 Principles of Radiation Oncology, Linear Accelerators & Treatment Planning 27.2 Teletherapy vs. Brachytherapy, Patient Immobilization & Side Effect Management 27.3 Isodose Planning, Treatment Delivery Methods & Radiobiologic Principles in Radiation Therapy
28 Mammography & Dental Radiography
28.1 Mammography: Equipment, CC and MLO Positioning, Compression & Breast Pathology 28.2 Dental Radiography: Paralleling and Bisecting Techniques, Bitewing, Occlusal, Panoramic & Cephalometric
29 Medical Terminology for Radiologic Technology
29.1 Medical Word Building: Root Words, Combining Forms, Prefixes & Suffixes 29.2 Medical Terms in General Medicine, Abbreviations, Symbols & Critiquing Requests and Reports
30 Radiology Administration, Organization & Leadership
30.1 Organizational Structure, Staffing & Licensing Requirements of a Radiology Facility 30.2 Radiology Department Management: Job Descriptions, Duties, Leadership Styles & Entrepreneurial Skills
4.1 ALARA Principles, Structural Shielding & Dose Limits
Key Takeaways Explain This Topic AI
ALARA combines time, distance and shielding while achieving the justified medical task; point-source distance calculations and constant-rate time calculations require explicit assumptions.
PNRI CPR Part 3 Revision 02 excludes machine X-rays and related facilities under DOH–FDA; apply its dose table only within its stated scope.
For adult workers under PNRI section 23.1, effective dose and lens equivalent dose each have a 20 mSv/year five-year average and a 50 mSv single-year ceiling; extremities or skin have a 500 mSv annual limit.
The declared-worker embryo/fetal provision is 1 mSv during the entire pregnancy; young apprentices have distinct limits, including 20 mSv/year to the lens.
Shielding must address the actual source, workload, beam directions, occupancy and approved design; patient-release and visitor criteria are not universal caregiver dose allowances.
Last updated: October 2026
4.1 ALARA, Shielding and the Correct Regulatory Scope
Radiation-protection questions require two decisions: identify the exposure category, then apply the rule that actually governs the source and situation. A number remembered from an older textbook can be wrong for the lens of the eye, pregnancy or the regulator named in the question.
As low as reasonably achievable (ALARA) means optimizing protection while achieving the medical task. A justified examination still needs adequate image quality; simply reducing exposure until the image is unusable can lead to a repeat. For workers and the public, dose limits are ceilings, not exposure targets. The medical exposure of the patient is managed through justification and optimization rather than by applying an occupational annual dose limit.
Time, distance and shielding: use the assumptions
Time: At a constant dose rate, dose equals rate multiplied by time. If a hypothetical work location has a steady equivalent-dose rate of 2 microSv/hour, spending 30 minutes there gives 1 microSv: convert 30 minutes to 0.5 hour before multiplying. A varying rate requires accounting for its variation. This arithmetic is not a prediction of a patient's diagnostic dose.
Distance: For a point-source approximation without intervening attenuation or changes in geometry: I 2 = I 1 ( d 1 d 2 ) 2 I_2 = I_1\left(\frac{d_1}{d_2}\right)^2 I 2 = I 1 ( d 2 d 1 ) 2
Doubling distance gives one-quarter of the initial intensity; tripling it gives one-ninth, approximately 11.1%. A patient is an extended scatter source, so an actual staff dose need not follow that idealization exactly. Use distance together with positioning, barriers and the facility's approved operating procedures. Two metres is approximately 6.6 feet; it is not an exact conversion to six feet or a universal safe-distance guarantee.
Shielding: Material, thickness and beam quality determine attenuation. A half-value layer (HVL) reduces the specified beam quantity to one-half under the stated conditions. Two identical HVLs leave one-quarter if the same attenuation model applies. A tenth-value layer (TVL) leaves one-tenth. With a constant exponential attenuation coefficient, one TVL is approximately 3.32 HVLs; a broad diagnostic spectrum can change as it passes through material, so that ratio is not a universal design shortcut.
Identify the regulator before applying a limit
The final PNRI Code of Regulations, CPR Part 3, Revision 02 , published in the Official Gazette on March 8, 2021, governs the practices and licensed materials within its scope. Section 2(b)(1) expressly separates X-rays and other electrically generated radiation and related facilities under the Department of Health–Food and Drug Administration (DOH–FDA) . PNRI training or dosimetry services do not make PNRI Part 3 the licensing rule for every diagnostic X-ray room.
When an examination case expressly asks about a PNRI-licensed radioactive-material practice, use the following current provisions. For a machine-X-ray facility, determine the applicable DOH–FDA requirements and facility authorization rather than silently transferring the PNRI table.
PNRI exposure category Quantity and current limit Provision
Adult worker Effective dose: 20 mSv/year averaged over five consecutive years; 50 mSv in any single year 23.1(a)(1)
Adult worker Lens equivalent dose: 20 mSv/year averaged over five consecutive years; 50 mSv in any single year 23.1(a)(2)
Adult worker Extremities or skin equivalent dose: 500 mSv in a year 23.1(a)(3)
Apprentice/student aged 16–18, in the stated training or study situation Effective dose: 6 mSv/year; lens: 20 mSv/year; extremities or skin: 150 mSv/year 23.2(a)
Embryo/fetus of a declared pregnant worker Dose equivalent: no more than 1 mSv during the entire pregnancy from occupational exposure 23.1(b)
Member of the public Effective dose: ordinarily 1 mSv/year; lens: 15 mSv/year; skin: 50 mSv/year 44(a)
The adult effective-dose and lens limits are separate checks. Effective doses of 24, 22, 18, 16 and 20 mSv total 100 mSv, averaging 20 mSv/year; none exceeds the 50 mSv single-year ceiling. That satisfies those two effective-dose numerical tests , but says nothing about a worker's separately assessed lens or extremity doses, and does not establish that protection is optimized. Do not replace the five-year test with a standalone 50 mSv annual allowance.
For the young-apprentice category, access to a controlled area is supervised and only for the specified training or study purposes. Section 23.2 also prohibits occupational exposure of persons under 16. Age and purpose matter; the lower limits do not authorize unsupervised radiation work.
After pregnancy notification, the employer must adapt working conditions to provide the required embryo/fetal protection. Section 24 does not make notification a reason for automatic exclusion from work. The 1 mSv provision concerns the embryo/fetus throughout pregnancy, not a new annual whole-body limit for the worker and not an invented uniform monthly allocation.
Public exposure, carers and visitors are different cases
Section 44(a)(2) permits a higher effective dose in a single year in special circumstances while retaining a five-year average no greater than 1 mSv/year. It does not reproduce the old text's explicit universal 5 mSv single-year ceiling, and it is not permission to disregard authorization or optimization.
Two particular PNRI medical situations also require careful reading:
Under section 40(b), release after radionuclide therapy requires the medical physicist or Radiation Protection Officer to establish that the dose likely to reach public and family members will not exceed 3 mSv. Section 40(c) additionally requires protective instructions, including written instructions, when another person's total effective dose equivalent is likely to exceed 1 mSv.
Under section 44(c), a visitor to a patient who cannot be released under section 40 may receive more than 1 mSv only when the dose does not exceed 3 mSv and the authorized user determines beforehand that the visit is appropriate.
These are specific release and visitor provisions. They do not create a universal 3 mSv allowance for all carers, visitors or diagnostic procedures. Carer/comforter protection also involves the applicable dose constraints and information requirements. Absorbed dose is expressed in gray; equivalent and effective dose use sievert. A table headed “absorbed dose in mSv” confuses different quantities.
Structural barriers: a design task, not a thickness slogan
A primary barrier intercepts the intended useful beam. Secondary shielding addresses scattered and leakage radiation. Their adequacy depends on the intended beam directions and installation. A wall, door, viewing window or joint can undermine a design if its protection does not match the approved specification.
Assess the source spectrum and output, workload, geometry, use of each barrier and occupancy of adjacent areas. Workload describes expected radiation production over the design period; a use factor describes the fraction directed toward a particular primary barrier; an occupancy factor describes occupation of the protected location. Do not assign one fixed use or occupancy factor merely because an area is called a floor, corridor or car park. The calculation's units and assumptions must match its method.
For example, changing a neighbouring store into an occupied office can change shielding needs even when the machine stays put. Check the proposed use against the approved assessment before operating under the changed conditions. A blanket 1/16-inch primary wall, 1/32-inch secondary wall, seven-foot height or one particular glass thickness cannot establish adequacy for every room. Facility design and review must follow the applicable national requirements and actual installation.
Sources: PNRI final CPR Part 3, Revision 02 , especially sections 1–2, 23–25, 35–38, 40 and 44–47; IAEA SSG-46, X-ray room design, paragraphs 3.9–3.16 ; IAEA Diagnostic Radiology Physics, chapter 24.7 ; ICRP Publication 105 .