Study guide

27.3 Isodose Planning, Treatment Delivery Methods & Radiobiologic Principles in Radiation Therapy

Philippine Radiologic Technologists Licensure Examination Exam

Track your progress as you read

Finished sections get a check mark.

1 Subject 1, Chapter 1: Physics of Radiology & X-Ray Production

1.1 Atomic Structure, Electromagnetic Spectrum & X-Ray Production Mechanisms 1.2 X-Ray Tube Components, Target Interactions & Emission Spectrum 1.3 Photon Interactions with Matter: Photoelectric, Compton, Coherent & Pair Production

2 Subject 1, Chapter 2: Radiographic Equipment & Circuitry

2.1 High-Voltage Generators, Transformers & Rectification Circuits 2.2 Automatic Exposure Control (AEC), Beam Restriction & Quality Control 2.3 Tube Rating Charts, Extending Tube Life, Mechanical Malfunction & Preventive Maintenance

3 Subject 1, Chapter 3: Radiobiology & Cellular Response

3.1 Radiation Interaction with Tissue, Direct/Indirect Action & LET/RBE 3.2 Law of Bergonie & Tribondeau, Deterministic vs. Stochastic Effects 3.3 Dose-Response Relationships, Embryo and Fetal Effects & Acute Radiation Syndrome

4 Subject 1, Chapter 4: Radiation Protection & Dose Limits

4.1 ALARA Principles, Structural Shielding & Dose Limits 4.2 Personnel Dosimetry & Patient Dose Reduction Techniques 4.3 Dose Calculation Problems: Time, Distance, Shielding & Structural Barrier Design

5 Subject 1, Chapter 5: Imaging Informatics & Quality Assurance

5.1 PACS Architecture, DICOM Standards & HL7 Integration 5.2 Quality Assurance & Quality Control Protocols in Diagnostic Radiography 5.3 Radiology Workflow, RIS/HIS Integration, Teleradiology & Informatics Quality Assurance

6 Subject 2, Chapter 6: Film-Screen Radiography & Sensitometry

6.1 Film Emulsion, Latent Image Formation & Darkroom Chemistry 6.2 Sensitometric Curve (H&D Curve), Film Speed & Contrast Characteristics 6.3 Radiographic Film Analysis: Processing Faults, Handling Artifacts & Corrective Measures

7 Subject 2, Chapter 7: Technical Factors & Radiographic Quality

7.1 Density/Brightness, Contrast, Spatial Resolution & Distortion Controls 7.2 Exposure Math: Inverse Square Law, 15% Rule & Grid Conversion Factors 7.3 Technique Compensation: Age, Pathology, Cast and Orthopaedic Devices, Screen Speed & Beam Restriction

8 Subject 2, Chapter 8: Computed Radiography (CR)

8.1 Photostimulable Phosphor (PSP) Plates & CR Reader Mechanics 8.2 Image Processing, CR Artifacts & Erasure Protocols

9 Subject 2, Chapter 9: Digital Radiography (DR)

9.1 Flat-Panel Detectors: Direct vs. Indirect Conversion & TFT Arrays 9.2 Detective Quantum Efficiency (DQE), Modulation Transfer Function (MTF) & Dynamic Range

10 Subject 2, Chapter 10: Exposure Indicators & Image Evaluation

10.1 Exposure Indicators (S-Number, EI, DI), Windowing & Look-Up Tables (LUT) 10.2 Image Critique Checklist, Artifact Identification & Quality Control Standards 10.3 Image Display & Hard-Copy Output: Monitor Classification, DICOM GSDF, Dry vs Wet Laser Imaging

11 Subject 3, Chapter 11: Chest, Abdomen & Routine Positioning Concepts

11.1 Anatomical Terminology, Body Planes & Chest Radiography (PA, Lateral, Decubitus) 11.2 Abdominal Radiography: Acute Abdomen Series & Erect/Supine Protocols 11.3 Radiologic Surface Anatomy, Body Habitus & Sectional Body Cuts

12 Subject 3, Chapter 12: Upper & Lower Extremities & Girdles

12.1 Upper Limb & Shoulder Girdle Positioning (Hand, Wrist, Forearm, Elbow, Humerus, Shoulder) 12.2 Lower Limb & Pelvic Girdle Positioning (Foot, Ankle, Leg, Knee, Femur, Pelvis, Hip)

13 Subject 3, Chapter 13: Spine & Bony Thorax

13.1 Cervical, Thoracic & Lumbar Spine Radiography & Trauma Adaptations 13.2 Sacrum, Coccyx, Sacroiliac Joints & Bony Thorax (Ribs & Sternum)

14 Subject 3, Chapter 14: Cranium, Facial Bones & Paranasal Sinuses

14.1 Skull Positioning: Towne, Caldwell, Lateral & SMV Projections 14.2 Facial Bones, Orbits, Zygomatic Arches & Paranasal Sinuses

15 Subject 3, Chapter 15: Contrast Media Studies & Special Procedures

15.1 Gastrointestinal Contrast Procedures (Esophagram, UGI, Small Bowel, Barium Enema) 15.2 Genitourinary, Biliary & Special Fluoroscopic Studies (IVU, Cystography, ERCP, Myelography) 15.3 Reproductive System Studies: Hysterosalpingography, Pelvimetry & Male Reproductive Procedures 15.4 Nasopharyngography, Sialography & Fistulography / Sinus Tract Visualization

16 Subject 4, Chapter 16: Human Anatomy, Physiology & Pathology Integration

16.1 Body System Anatomy & Systemic Physiology Overview for Radiographers 16.2 Radiologic Pathology: Image Manifestations of Neoplastic, Inflammatory & Traumatic Conditions

17 Subject 4, Chapter 17: Patient Assessment, Communication & Informed Consent

17.1 Professional Communication, History Taking & Patient Rights 17.2 Informed Consent, Medical Documentation & Patient Transfer Safety

18 Subject 4, Chapter 18: Infection Control & Vital Signs Monitoring

18.1 Standard Precautions, Asepsis, Sterilization & Isolation Protocols 18.2 Measurement & Assessment of Vital Signs (BP, Pulse, Respiration, Temperature)

19 Subject 4, Chapter 19: Emergency Care & Aseptic Venipuncture

19.1 Basic Life Support (BLS), CPR Concepts & Emergency Response in Radiology 19.2 Aseptic Venipuncture Technique, IV Maintenance & Extravasation Care

20 Subject 4, Chapter 20: Professional Ethics, Jurisprudence & RA 7431

20.1 Republic Act No. 7431 (Radiologic Technology Act of 1992) & Board Rules 20.2 Code of Professional Ethics, Legal Liabilities, Malpractice & Negligence 20.3 Bioethical Principles in Practice, Professional Virtues & Interprofessional Relationships

21 Subject 5, Chapter 21: Diagnostic Ultrasonography

21.1 Ultrasound Physics, Transducer Construction & Doppler Principles 21.2 Acoustic Artifacts, Clinical Applications & Safety (TI/MI) 21.3 Clinical Ultrasound Examinations: Indications, Patient Preparation, Scanning Protocols & Transducer Selection

22 Subject 5, Chapter 22: Computed Tomography (CT)

22.1 CT Physics, Gantry Components, Detectors & Helical/Multislice Acquisition 22.2 Hounsfield Units, Windowing, CT Artifacts & Radiation Dose (CTDI/DLP)

23 Subject 5, Chapter 23: Magnetic Resonance Imaging (MRI)

23.1 MRI Physics, Nuclear Spin, T1/T2 Relaxation & Pulse Sequences 23.2 MRI Safety (Zones I-IV, SAR, Metallic Implants) & Common Artifacts 23.3 MRI Examination Protocols, Patient Preparation, Gadolinium Contrast & Sectional MRI Anatomy

24 Subject 5, Chapter 24: Interventional Radiology & Vascular Imaging

24.1 Vascular Access, Seldinger Technique & Digital Subtraction Angiography (DSA) 24.2 Interventional Procedures (Embolization, Angioplasty, Stenting) & C-Arm Radiation Safety 24.3 Interventional Patient Management: Contrast Selection, Pre-Procedure Workup & Post-Procedure Care

25 Subject 5, Chapter 25: Contrast Media Pharmacology & Adverse Reactions

25.1 Classification of Contrast Agents: Osmolality, Viscosity & Iodine Concentration 25.2 Adverse Contrast Reactions (Mild, Moderate, Severe) & Emergency Treatment Protocols 25.3 General Pharmacologic Principles: Pharmacokinetics, Pharmacodynamics, Drug Categories & the Rights of Drug Safety

26 Subject 5, Chapter 26: Nuclear Medicine & Molecular Imaging

26.1 Radioisotopes, Radiopharmaceuticals & Gamma Camera / SPECT Operation 26.2 Positron Emission Tomography (PET/CT) & Unsealed Radiation Source Safety

27 Subject 5, Chapter 27: Radiation Therapy & Radiation Oncology

27.1 Principles of Radiation Oncology, Linear Accelerators & Treatment Planning 27.2 Teletherapy vs. Brachytherapy, Patient Immobilization & Side Effect Management 27.3 Isodose Planning, Treatment Delivery Methods & Radiobiologic Principles in Radiation Therapy

28 Mammography & Dental Radiography

28.1 Mammography: Equipment, CC and MLO Positioning, Compression & Breast Pathology 28.2 Dental Radiography: Paralleling and Bisecting Techniques, Bitewing, Occlusal, Panoramic & Cephalometric

29 Medical Terminology for Radiologic Technology

29.1 Medical Word Building: Root Words, Combining Forms, Prefixes & Suffixes 29.2 Medical Terms in General Medicine, Abbreviations, Symbols & Critiquing Requests and Reports

30 Radiology Administration, Organization & Leadership

30.1 Organizational Structure, Staffing & Licensing Requirements of a Radiology Facility 30.2 Radiology Department Management: Job Descriptions, Duties, Leadership Styles & Entrepreneurial Skills

27.3 Isodose Planning, Treatment Delivery Methods & Radiobiologic Principles in Radiation Therapy

Key Takeaways Explain This Topic AI

An isodose curve joins points receiving the same dose, expressed as a percentage of a reference dose, and an isodose plan is the two- or three-dimensional map used to judge target coverage and organ-at-risk sparing.

Percentage depth dose rises to a maximum at the depth of dose maximum then falls with depth, and the depth of dose maximum increases with beam energy, which produces the skin-sparing effect of megavoltage beams.

Parallel-opposed, wedged-pair, three-field and multi-field arrangements are chosen to shape the high-dose volume around the target while keeping organs at risk below their tolerance doses.

The four Rs of radiobiology that justify fractionation are repair of sublethal damage, redistribution within the cell cycle, repopulation, and reoxygenation of hypoxic tumour cells.

Conventional fractionation delivers about 1.8 to 2 Gy per fraction once daily on weekdays, which exploits the greater repair capacity of late-responding normal tissue relative to tumour.

Last updated: August 2026

27.3 Isodose Planning, Treatment Delivery Methods & Radiobiologic Principles in Radiation Therapy

The Enhanced TOS lists Principles of Isodose Planning and Radiobiologic Principles in Radiation Therapy as its own sub-topic worth 2 items , with the competency to distinguish the procedures of isodose planning, methods of treatment, and various dose theories . Section 27.1 covered linear accelerator hardware and the treatment-planning workflow, and Section 27.2 covered teletherapy versus brachytherapy, immobilisation and side effects. This section supplies the dosimetric and radiobiological reasoning that connects them.

1. Isodose Curves and Isodose Plans

An isodose curve is a line joining all points in a phantom or patient that receive the same absorbed dose , normally expressed as a percentage of a stated reference dose — most often the dose at the depth of maximum dose on the central axis, or the prescribed dose at the isocentre.

An isodose chart is the family of such curves for one beam of stated energy, field size and source-to-surface distance. An isodose plan is the composite of all beams in the treatment, displayed on the planning CT.

What a planner reads off a plan:

Target coverage — the prescription isodose (commonly 95%) should encompass the planning target volume.

Homogeneity — how uniform the dose is within the target; conventionally the aim is roughly within 95% to 107% of the prescription.

Conformity — how tightly the high-dose region hugs the target rather than spilling into normal tissue.

Organ-at-risk doses — read as maximum point dose, or as the volume receiving a stated dose, and compared with published tolerance constraints.

Hot spots — regions above the prescription, particularly outside the target, which are minimised by wedges, field weighting and beam-angle selection.

Dose-volume histogram. The modern companion to the isodose display, plotting for each structure the fraction of its volume receiving at least a given dose. It compresses a three-dimensional plan into a curve per structure, so target coverage and organ sparing can be compared between competing plans at a glance.

Characteristics of the isodose distribution

  • Feature Behaviour
  • Central axis Highest dose at a given depth

Penumbra The rapid dose fall-off region at the field edge, widened by a larger source size and by increased distance from the collimator

  • Field size Larger fields deliver greater dose at depth for the same surface dose, because of increased scatter
  • Energy Higher energy shifts the curves deeper and sharpens the fall-off beyond the target
  • Tissue inhomogeneity Lung transmits more, so isodose lines bulge deeper through lung; bone attenuates more
  • Surface obliquity An angled surface tilts the isodose curves; a wedge or bolus compensates
  • 2. Percentage Depth Dose and the Depth of Dose Maximum

Percentage depth dose (PDD) is the dose at a given depth expressed as a percentage of the dose at the depth of maximum dose, on the central axis, for a stated field size and distance.

The curve rises steeply from the surface to the depth of dose maximum (d-max) , then falls approximately exponentially with depth.

  • Beam Approximate depth of dose maximum
  • Superficial / orthovoltage kilovoltage At or very near the surface
  • Cobalt-60 (1.25 MeV average) About 0.5 cm
  • 6 MV linear accelerator About 1.5 cm
  • 10 MV About 2.5 cm
  • 18 MV About 3.0-3.5 cm

Skin sparing is the direct consequence: because the dose builds up over the first centimetres as secondary electrons come into equilibrium, a megavoltage beam deposits far less dose in the skin than at depth. This is the single greatest advantage of megavoltage over orthovoltage therapy, and it is lost when a bolus is deliberately placed on the skin to bring d-max to the surface for a superficial target such as a chest-wall recurrence.

Percentage depth dose increases with higher beam energy, larger field size (more scatter) and greater source-to-surface distance, and decreases with greater depth.

3. Beam Modifiers

Modifier Function

Wedge (physical, motorised or dynamic) Progressively attenuates one side of the beam, tilting the isodose curves; used to compensate for an oblique surface and to combine two beams at an angle without a hot spot in the overlap

Bolus Tissue-equivalent material on the skin; removes skin sparing where surface dose is wanted, and compensates for surface irregularity

Compensator A shaped attenuator away from the skin that corrects for missing tissue while preserving skin sparing

Blocks / multileaf collimator (MLC) Shape the field to the target outline and shield organs at risk

Flattening filter Produces a uniform beam profile across the field; flattening-filter-free modes deliver higher dose rates for stereotactic work

4. Beam Arrangements and Treatment Methods

  • Arrangement Description Typical use
  • Single field One beam Superficial targets, some palliative treatments

Parallel-opposed pair Two beams 180 degrees apart Simple, homogeneous through the midplane; whole brain, some palliative spine and bone treatments

Wedged pair Two beams at an angle with wedges Superficial and lateralised targets such as some head and neck sites

Three-field / four-field box Anterior, posterior and lateral fields Pelvic targets; the box confines a high-dose region around the target while sparing anterior and posterior tissue

Multi-field conformal (3D-CRT) Several shaped beams from CT-based planning The general workhorse

Intensity-modulated radiotherapy (IMRT) Beam intensity varied across each field by moving multileaf collimators Concave targets wrapping around an organ at risk, such as prostate adjacent to rectum or head and neck adjacent to parotid

Volumetric modulated arc therapy (VMAT) Continuous gantry rotation with simultaneously varying dose rate, leaf position and gantry speed Fast, highly conformal delivery

Stereotactic radiosurgery / body radiotherapy (SRS / SBRT) Very high dose in one or a few fractions, with steep gradients and rigorous immobilisation and image guidance Small brain lesions, early lung tumours, oligometastases

Brachytherapy Sealed sources placed within or adjacent to the target — intracavitary, interstitial, intraluminal or surface Cervix, prostate, oesophagus, skin

Image-guided radiotherapy (IGRT) — cone-beam CT, planar imaging or surface guidance at the machine before each fraction — verifies position and is what makes tight planning margins safe.

Isocentric (SAD) technique places the isocentre at the target centre so the gantry can rotate around the patient without repositioning, and has largely displaced the older fixed source-to-surface distance (SSD) technique.

  • 5. Radiobiologic Principles and Dose Theories
  • The therapeutic ratio

The whole enterprise rests on the ratio between tumour control probability and normal tissue complication probability . Everything in planning and fractionation is an attempt to widen the gap between the two curves.

The four Rs of radiobiology — why treatment is fractionated

R Mechanism Effect

Repair of sublethal damage Normal tissue, especially late-responding tissue, repairs sublethal damage between fractions more effectively than tumour Favours normal tissue — the principal justification for fractionation

Redistribution (reassortment) Cells surviving a fraction redistribute through the cell cycle into more radiosensitive phases Favours tumour kill ; cells are most sensitive in G2 and M , most resistant in late S

Repopulation Surviving clonogens proliferate between fractions Favours tumour if treatment is prolonged, which is why gaps and unplanned interruptions are avoided

Reoxygenation Hypoxic tumour cells become oxygenated as the tumour shrinks Favours tumour kill ; the oxygen enhancement ratio for x-rays is roughly 2.5-3 , so oxygenated cells are far more radiosensitive

A fifth R, intrinsic radiosensitivity , is often added to explain why tumours of the same histology respond differently.

The law of Bergonie and Tribondeau

Cells are most radiosensitive when they are highly mitotic , undifferentiated , and have a long mitotic future . Applied to therapy, this is why rapidly dividing tumours and rapidly renewing normal tissues — bone marrow, intestinal mucosa, skin basal layer, gonads — respond and react earliest.

Early versus late responding tissue

Early (acute) responding Late responding

Tissues Skin, mucosa, bone marrow, intestinal epithelium Spinal cord, lung, kidney, subcutaneous fibrosis, blood vessels

Timing of reaction During and shortly after treatment Months to years later

Sensitivity to fraction size Relatively insensitive Highly sensitive — large fractions disproportionately damage late-responding tissue

Reversibility Usually heals Often permanent

This distinction is the reason conventional fractionation uses about 1.8 to 2 Gy per fraction, once daily, five days a week : small fractions spare late-responding normal tissue, while the cumulative dose still controls the tumour.

Altered fractionation schedules

  • Schedule Pattern Rationale
  • Conventional About 1.8-2 Gy per fraction, once daily, 5 days a week Standard balance

Hyperfractionation Smaller fractions, more than once daily, similar overall time, higher total dose Further spares late-responding tissue while escalating tumour dose

Accelerated fractionation Standard or slightly reduced fraction size, shorter overall time Counters repopulation in rapidly proliferating tumours

Hypofractionation Larger fractions, fewer of them Shorter courses; used in palliation and, with modern conformality and image guidance, in breast, prostate and stereotactic treatments

Split course A planned gap mid-treatment Improves tolerance, but the gap permits repopulation and is generally avoided

Dose concepts

Absorbed dose is measured in gray (Gy) , one joule per kilogram. Radiation therapy is prescribed in gray, not sievert.

Fraction size, number of fractions and overall treatment time together determine biological effect; total dose alone does not.

The linear-quadratic model describes cell survival with an alpha component (single-hit, non-repairable) and a beta component (multi-hit, repairable), and the alpha/beta ratio characterises tissue response: roughly 10 Gy for early-responding tissue and most tumours , roughly 3 Gy for late-responding tissue . The lower the alpha/beta ratio, the more sensitive that tissue is to increased fraction size — the quantitative statement of the early-versus-late distinction above.

Tolerance doses for organs at risk are the planning constraints, conventionally expressed as the dose associated with a stated complication probability at a stated interval.

Radiosensitisers such as concurrent chemotherapy and oxygen increase tumour cell kill; radioprotectors aim to shield normal tissue. Hypoxia is the classic cause of radioresistance, which is why reoxygenation across a fractionated course matters so much.