Study guide
27.1 Principles of Radiation Oncology, Linear Accelerators & Treatment Planning
Philippine Radiologic Technologists Licensure Examination Exam
Track your progress as you read
Finished sections get a check mark.
1 Subject 1, Chapter 1: Physics of Radiology & X-Ray Production
1.1 Atomic Structure, Electromagnetic Spectrum & X-Ray Production Mechanisms 1.2 X-Ray Tube Components, Target Interactions & Emission Spectrum 1.3 Photon Interactions with Matter: Photoelectric, Compton, Coherent & Pair Production
2 Subject 1, Chapter 2: Radiographic Equipment & Circuitry
2.1 High-Voltage Generators, Transformers & Rectification Circuits 2.2 Automatic Exposure Control (AEC), Beam Restriction & Quality Control 2.3 Tube Rating Charts, Extending Tube Life, Mechanical Malfunction & Preventive Maintenance
3 Subject 1, Chapter 3: Radiobiology & Cellular Response
3.1 Radiation Interaction with Tissue, Direct/Indirect Action & LET/RBE 3.2 Law of Bergonie & Tribondeau, Deterministic vs. Stochastic Effects 3.3 Dose-Response Relationships, Embryo and Fetal Effects & Acute Radiation Syndrome
4 Subject 1, Chapter 4: Radiation Protection & Dose Limits
4.1 ALARA Principles, Structural Shielding & Dose Limits 4.2 Personnel Dosimetry & Patient Dose Reduction Techniques 4.3 Dose Calculation Problems: Time, Distance, Shielding & Structural Barrier Design
5 Subject 1, Chapter 5: Imaging Informatics & Quality Assurance
5.1 PACS Architecture, DICOM Standards & HL7 Integration 5.2 Quality Assurance & Quality Control Protocols in Diagnostic Radiography 5.3 Radiology Workflow, RIS/HIS Integration, Teleradiology & Informatics Quality Assurance
6 Subject 2, Chapter 6: Film-Screen Radiography & Sensitometry
6.1 Film Emulsion, Latent Image Formation & Darkroom Chemistry 6.2 Sensitometric Curve (H&D Curve), Film Speed & Contrast Characteristics 6.3 Radiographic Film Analysis: Processing Faults, Handling Artifacts & Corrective Measures
7 Subject 2, Chapter 7: Technical Factors & Radiographic Quality
7.1 Density/Brightness, Contrast, Spatial Resolution & Distortion Controls 7.2 Exposure Math: Inverse Square Law, 15% Rule & Grid Conversion Factors 7.3 Technique Compensation: Age, Pathology, Cast and Orthopaedic Devices, Screen Speed & Beam Restriction
8 Subject 2, Chapter 8: Computed Radiography (CR)
8.1 Photostimulable Phosphor (PSP) Plates & CR Reader Mechanics 8.2 Image Processing, CR Artifacts & Erasure Protocols
9 Subject 2, Chapter 9: Digital Radiography (DR)
9.1 Flat-Panel Detectors: Direct vs. Indirect Conversion & TFT Arrays 9.2 Detective Quantum Efficiency (DQE), Modulation Transfer Function (MTF) & Dynamic Range
10 Subject 2, Chapter 10: Exposure Indicators & Image Evaluation
10.1 Exposure Indicators (S-Number, EI, DI), Windowing & Look-Up Tables (LUT) 10.2 Image Critique Checklist, Artifact Identification & Quality Control Standards 10.3 Image Display & Hard-Copy Output: Monitor Classification, DICOM GSDF, Dry vs Wet Laser Imaging
11 Subject 3, Chapter 11: Chest, Abdomen & Routine Positioning Concepts
11.1 Anatomical Terminology, Body Planes & Chest Radiography (PA, Lateral, Decubitus) 11.2 Abdominal Radiography: Acute Abdomen Series & Erect/Supine Protocols 11.3 Radiologic Surface Anatomy, Body Habitus & Sectional Body Cuts
12 Subject 3, Chapter 12: Upper & Lower Extremities & Girdles
12.1 Upper Limb & Shoulder Girdle Positioning (Hand, Wrist, Forearm, Elbow, Humerus, Shoulder) 12.2 Lower Limb & Pelvic Girdle Positioning (Foot, Ankle, Leg, Knee, Femur, Pelvis, Hip)
13 Subject 3, Chapter 13: Spine & Bony Thorax
13.1 Cervical, Thoracic & Lumbar Spine Radiography & Trauma Adaptations 13.2 Sacrum, Coccyx, Sacroiliac Joints & Bony Thorax (Ribs & Sternum)
14 Subject 3, Chapter 14: Cranium, Facial Bones & Paranasal Sinuses
14.1 Skull Positioning: Towne, Caldwell, Lateral & SMV Projections 14.2 Facial Bones, Orbits, Zygomatic Arches & Paranasal Sinuses
15 Subject 3, Chapter 15: Contrast Media Studies & Special Procedures
15.1 Gastrointestinal Contrast Procedures (Esophagram, UGI, Small Bowel, Barium Enema) 15.2 Genitourinary, Biliary & Special Fluoroscopic Studies (IVU, Cystography, ERCP, Myelography) 15.3 Reproductive System Studies: Hysterosalpingography, Pelvimetry & Male Reproductive Procedures 15.4 Nasopharyngography, Sialography & Fistulography / Sinus Tract Visualization
16 Subject 4, Chapter 16: Human Anatomy, Physiology & Pathology Integration
16.1 Body System Anatomy & Systemic Physiology Overview for Radiographers 16.2 Radiologic Pathology: Image Manifestations of Neoplastic, Inflammatory & Traumatic Conditions
17 Subject 4, Chapter 17: Patient Assessment, Communication & Informed Consent
17.1 Professional Communication, History Taking & Patient Rights 17.2 Informed Consent, Medical Documentation & Patient Transfer Safety
18 Subject 4, Chapter 18: Infection Control & Vital Signs Monitoring
18.1 Standard Precautions, Asepsis, Sterilization & Isolation Protocols 18.2 Measurement & Assessment of Vital Signs (BP, Pulse, Respiration, Temperature)
19 Subject 4, Chapter 19: Emergency Care & Aseptic Venipuncture
19.1 Basic Life Support (BLS), CPR Concepts & Emergency Response in Radiology 19.2 Aseptic Venipuncture Technique, IV Maintenance & Extravasation Care
20 Subject 4, Chapter 20: Professional Ethics, Jurisprudence & RA 7431
20.1 Republic Act No. 7431 (Radiologic Technology Act of 1992) & Board Rules 20.2 Code of Professional Ethics, Legal Liabilities, Malpractice & Negligence 20.3 Bioethical Principles in Practice, Professional Virtues & Interprofessional Relationships
21 Subject 5, Chapter 21: Diagnostic Ultrasonography
21.1 Ultrasound Physics, Transducer Construction & Doppler Principles 21.2 Acoustic Artifacts, Clinical Applications & Safety (TI/MI) 21.3 Clinical Ultrasound Examinations: Indications, Patient Preparation, Scanning Protocols & Transducer Selection
22 Subject 5, Chapter 22: Computed Tomography (CT)
22.1 CT Physics, Gantry Components, Detectors & Helical/Multislice Acquisition 22.2 Hounsfield Units, Windowing, CT Artifacts & Radiation Dose (CTDI/DLP)
23 Subject 5, Chapter 23: Magnetic Resonance Imaging (MRI)
23.1 MRI Physics, Nuclear Spin, T1/T2 Relaxation & Pulse Sequences 23.2 MRI Safety (Zones I-IV, SAR, Metallic Implants) & Common Artifacts 23.3 MRI Examination Protocols, Patient Preparation, Gadolinium Contrast & Sectional MRI Anatomy
24 Subject 5, Chapter 24: Interventional Radiology & Vascular Imaging
24.1 Vascular Access, Seldinger Technique & Digital Subtraction Angiography (DSA) 24.2 Interventional Procedures (Embolization, Angioplasty, Stenting) & C-Arm Radiation Safety 24.3 Interventional Patient Management: Contrast Selection, Pre-Procedure Workup & Post-Procedure Care
25 Subject 5, Chapter 25: Contrast Media Pharmacology & Adverse Reactions
25.1 Classification of Contrast Agents: Osmolality, Viscosity & Iodine Concentration 25.2 Adverse Contrast Reactions (Mild, Moderate, Severe) & Emergency Treatment Protocols 25.3 General Pharmacologic Principles: Pharmacokinetics, Pharmacodynamics, Drug Categories & the Rights of Drug Safety
26 Subject 5, Chapter 26: Nuclear Medicine & Molecular Imaging
26.1 Radioisotopes, Radiopharmaceuticals & Gamma Camera / SPECT Operation 26.2 Positron Emission Tomography (PET/CT) & Unsealed Radiation Source Safety
27 Subject 5, Chapter 27: Radiation Therapy & Radiation Oncology
27.1 Principles of Radiation Oncology, Linear Accelerators & Treatment Planning 27.2 Teletherapy vs. Brachytherapy, Patient Immobilization & Side Effect Management 27.3 Isodose Planning, Treatment Delivery Methods & Radiobiologic Principles in Radiation Therapy
28 Mammography & Dental Radiography
28.1 Mammography: Equipment, CC and MLO Positioning, Compression & Breast Pathology 28.2 Dental Radiography: Paralleling and Bisecting Techniques, Bitewing, Occlusal, Panoramic & Cephalometric
29 Medical Terminology for Radiologic Technology
29.1 Medical Word Building: Root Words, Combining Forms, Prefixes & Suffixes 29.2 Medical Terms in General Medicine, Abbreviations, Symbols & Critiquing Requests and Reports
30 Radiology Administration, Organization & Leadership
30.1 Organizational Structure, Staffing & Licensing Requirements of a Radiology Facility 30.2 Radiology Department Management: Job Descriptions, Duties, Leadership Styles & Entrepreneurial Skills
27.1 Principles of Radiation Oncology, Linear Accelerators & Treatment Planning
Key Takeaways Explain This Topic AI
Radiation oncology aims for either definitive/curative tumor eradication or palliative symptom control, governed by the therapeutic ratio (Tissue Tolerance Dose / Tumor Lethal Dose).
Linear accelerators (Linacs) generate high-energy megavoltage X-ray beams via tungsten targets and flattening filters, or electron beams via scattering foils with the target retracted.
Microwave radiofrequency (RF) energy in Linacs is generated by a klystron (RF power amplifier for high energies) or magnetron (RF oscillator for low/mid energies) and transmitted through evacuated waveguides.
Multi-Leaf Collimators (MLCs) utilize independently driven tungsten leaves (40–120) to conform radiation beam shapes precisely to target contours while shielding healthy tissue.
Treatment target volumes progress according to ICRU criteria from Gross Tumor Volume (GTV) to Clinical Target Volume (CTV) and Planning Target Volume (PTV), incorporating microscopic disease and geometric setup margins.
Last updated: August 2026
- 27.1 Principles of Radiation Oncology, Linear Accelerators & Treatment Planning
- 1. Core Principles of Radiation Oncology
Radiation oncology is a clinical medical specialty that utilizes ionizing radiation to treat malignant neoplasms and select benign conditions. The therapeutic application of radiation relies on fundamental radiobiological principles to maximize tumor control probability while minimizing radiation-induced damage to adjacent healthy normal tissues.
Treatment Goals: Definitive (Curative) vs. Palliative Intent
Definitive (Curative) Radiation Therapy: Administered with the primary objective of achieving complete eradication of the tumor and long-term overall patient survival. Curative protocols typically utilize higher total radiation doses (e.g., 60 to 80 Gy delivered in standard daily fractions of 1.8 to 2.0 Gy per day) over a period of 6 to 8 weeks. Definitive radiation therapy may be delivered as a single modality or in combination with chemotherapy (chemoradiotherapy), surgery (neoadjuvant or adjuvant), or targeted biological agents.
Palliative Radiation Therapy: Administered to relieve distressing disease symptoms—such as severe bone pain from skeletal metastases, spinal cord compression, superior vena cava syndrome, or uncontrolled tumor hemorrhage—when cure is unattainable. Palliative courses utilize lower total radiation doses delivered in shorter, hypofractionated treatment schedules (e.g., 8 Gy in a single fraction, 20 Gy in 5 fractions, or 30 Gy in 10 fractions) to maximize quality of life and minimize hospital visit burden.
Therapeutic Ratio (Therapeutic Index)
The Therapeutic Ratio (TR) quantifies the relative safety and clinical efficacy of a given radiation therapy treatment plan. It is defined mathematically as: Therapeutic Ratio = Tissue Tolerance Dose Tumor Lethal Dose \text{Therapeutic Ratio} = \frac{\text{Tissue Tolerance Dose}}{\text{Tumor Lethal Dose}} Therapeutic Ratio = Tumor Lethal Dose Tissue Tolerance Dose
Tissue Tolerance Dose (e.g., TD 50/5): The radiation dose that results in a specified severe complication rate (e.g., 50% probability of severe late tissue complication within 5 years) in a given normal critical organ.
Tumor Lethal Dose: The radiation dose required to achieve local tumor control or complete eradication (typically defined as a 95% local tumor control probability).
Clinical Significance: When the Therapeutic Ratio is greater than 1.0 , the tumor lethal dose is lower than the surrounding normal tissue tolerance limit, permitting successful cure without causing unacceptable normal tissue morbidity. When the Therapeutic Ratio is less than or equal to 1.0 , the tumor is radioresistant relative to surrounding critical structures, requiring advanced conformal beam shaping, radiosensitizers, or altered fractionation schedules to elevate the effective therapeutic window.
2. Linear Accelerator (Linac) Hardware & Beam Mechanics
Modern external beam radiation therapy is predominantly delivered using a medical Linear Accelerator (Linac) . A Linac uses high-frequency microwave radiofrequency (RF) fields to accelerate electrons to high kinetic energies (typically 4 to 25 MeV) along an evacuated linear beam waveguide. +-------------------------------------------------------------------------+
- | LINAC BEAM DELIVERY PATH |
- | |
- | [Electron Gun] ---> [Accelerating Waveguide] ---> [Bending Magnet] |
- | | |
- | v |
- | +--------------------------------------------------------------+ |
- | | X-RAY MODE: [Tungsten Target] -> [Flattening Filter] -> [MLC]| |
- | | ELECTRON MODE: [Target Retracted] -> [Scattering Foil]->[MLC]| |
- | +--------------------------------------------------------------+ |
- +-------------------------------------------------------------------------+
- Major Hardware Subsystems
Drive Stand: Houses the auxiliary power, gas, and cooling infrastructure, including:
RF Power Source:
Magnetron: A high-power microwave oscillator that generates RF power in short pulses; commonly utilized in low-to-mid energy Linacs (e.g., 4 to 6 MV photon energy).
Klystron: A high-power RF amplifier that requires a low-power RF driver signal; utilized in high-energy, dual-photon-energy Linacs (e.g., 6 to 18 MV) due to superior microwave power output capability and frequency stability.
RF Waveguide System: Evacuated hollow copper pipes filled with sulfur hexafluoride ( S F 6 SF_6 S F 6 ) dielectric gas to prevent electrical arcing, which transmit microwave power from the RF source to the accelerating structure.
Circulator: A one-way microwave valve positioned between the RF power source and waveguide that prevents reflected microwave energy from returning to damage the klystron or magnetron.
Gantry & Accelerating Structure:
Electron Gun: Contains a heated cathode filament that releases electrons via thermionic emission and a pulsed grid anode that injects electron bunches into the accelerating waveguide.
Accelerating Waveguide: A copper structure divided into resonant cavities. Electrons travel through these cavities, gaining energy by surfing on the oscillating electric fields of RF microwave standing or traveling waves.
Vacuum System: Maintains an ultra-high vacuum ( 10 − 6 10^{-6} 1 0 − 6 to 10 − 8 10^{-8} 1 0 − 8 Torr) inside the accelerating structure to prevent electron collisions with gas molecules.
Bending Magnet Assembly:
Because long accelerating waveguides are oriented horizontally inside the gantry, a magnetic bending system (typically a 270° achromatic bending magnet or 90° bending magnet) redirects the high-energy electron beam vertically downward toward the patient treatment couch.
Treatment Head & Beam Modifiers:
X-Ray / Photon Mode: The electron beam strikes a water-cooled, high-atomic-number (high-Z) target (typically tungsten). Through Bremsstrahlung interactions , high-energy megavoltage X-ray photons are produced. Because Bremsstrahlung X-ray production is strongly forward-peaked in the megavoltage range, a high-Z flattening filter (cone-shaped metallic absorber) is inserted into the beam path to create a uniform, flat intensity profile across the treatment field.
Electron Mode: The tungsten target and flattening filter are retracted out of the beam path. A thin, low-Z scattering foil (e.g., aluminum or copper) is inserted to broaden the narrow electron pencil beam into a uniform, clinically usable electron field for superficial tumor treatment.
Multi-Leaf Collimators (MLC): Consist of 40 to 120 pairs of motor-driven, high-density tungsten leaves (typically 0.5 to 1.0 cm thick at isocenter). Each leaf moves independently under computer control to shape dynamic, highly conformal radiation field borders that continuously match complex tumor contours during treatment delivery.
3. Linac Components Summary Table
Linac Component Structural / Physical Mechanism Role in Photon (X-Ray) Mode Role in Electron Mode
Electron Gun Thermionic emission filament with grid anode Injects electron bunches into waveguide Injects electron bunches into waveguide
Klystron / Magnetron RF microwave generation source Supplies high-power microwaves to accelerate electrons Supplies high-power microwaves to accelerate electrons
Bending Magnet 270° achromatic magnetic deflection field Bends electron beam downward toward treatment head Bends electron beam downward toward treatment head
Tungsten Target High-Z water-cooled metallic plate Inserted: Converts electrons to Bremsstrahlung photons Retracted: No X-ray conversion target used
Flattening Filter Cone-shaped high-Z beam absorber Inserted: Flattens forward-peaked photon beam Retracted: Retracted out of the beam path
Scattering Foil Thin low-Z metallic foil Retracted: Retracted out of photon beam path Inserted: Broadens electron pencil beam uniformly
Multi-Leaf Collimator (MLC) Independently driven tungsten leaves Shapes conformal static or dynamic photon fields Primary jaws open wide; electron applicator cone used
4. Treatment Planning Process & Target Volume Definitions
The modern treatment planning process transforms diagnostic imaging data into an optimized, highly localized radiation dose distribution.
Workflow Steps
CT Simulation: The patient is positioned on a flat couch top using custom immobilization devices. A dedicated CT simulator acquires volumetric scan data with external radio-opaque skin markers (tattoos) to establish a baseline reference coordinate system (isocenter).
Contouring & Volume Segmentation: Radiation oncologists outline target volumes and adjacent normal organs on the CT dataset according to ICRU (International Commission on Radiation Units and Measurements) Reports 50 and 62 standards.
Dose Calculation & Plan Optimization: Dosimetrists and medical physicists select beam angles, beam energies, and leaf movements (3D-CRT forward planning vs. IMRT inverse planning) to satisfy clinical dose-volume histogram (DVH) constraints.
5. ICRU Target Volume & Critical Structure Definitions Table
ICRU Volume Term Official Definition Included Biological / Geometric Margins Clinical Significance
Gross Tumor Volume (GTV) Demonstrated palpable or visible extent of malignant growth Primary tumor, metastatic lymph nodes, visible lesions Baseline tumor volume identified on CT, MRI, or PET
Clinical Target Volume (CTV) Anatomic tissue volume containing GTV plus subclinical microscopic disease GTV + subclinical microscopic tumor spread margin Must receive 100% of prescribed curative radiation dose
Internal Target Volume (ITV) CTV expanded to account for internal organ movement CTV + internal physiological motion margin (respiration, filling) Accounts for respiratory tracking or organ motion
Planning Target Volume (PTV) Geometric volume expanded around CTV/ITV CTV/ITV + setup margin (patient motion, machine tolerance) Ensures prescribed dose is delivered despite setup uncertainties
Organs at Risk (OAR) Normal tissue or critical organ sensitive to radiation Anatomical boundaries of normal critical structures (e.g., spinal cord) Radiation dose strictly limited to prevent severe morbidity
6. Modern Radiation Therapy Delivery Modalities
3D Conformal Radiation Therapy (3D-CRT): Uses 3D CT images to shape multiple static photon beams (typically 3 to 6 fields) matching the PTV shape via MLCs, using forward planning.
Intensity-Modulated Radiation Therapy (IMRT): Advanced delivery technique using inverse planning optimization algorithms. Dynamic MLC leaves move across the beam during irradiation to modulate beam intensity, creating concave dose distributions around OARs.
Image-Guided Radiation Therapy (IGRT): Incorporates daily pre-treatment imaging (such as cone-beam CT [CBCT], planar KV/MV radiography, or surface optical tracking) to detect and correct anatomical setup deviations prior to beam delivery.
Stereotactic Radiosurgery (SRS) & Stereotactic Body Radiotherapy (SBRT): Delivers ultra-high, ablative radiation doses in 1 to 5 fractions with sub-millimeter positioning accuracy. SRS treats small intracranial lesions, whereas SBRT (also called SABR) treats localized extracranial tumors in lung, liver, spine, or prostate.