Study guide
3.3 Dose-Response Relationships, Embryo and Fetal Effects & Acute Radiation Syndrome
Philippine Radiologic Technologists Licensure Examination Exam
Track your progress as you read
Finished sections get a check mark.
1 Subject 1, Chapter 1: Physics of Radiology & X-Ray Production
1.1 Atomic Structure, Electromagnetic Spectrum & X-Ray Production Mechanisms 1.2 X-Ray Tube Components, Target Interactions & Emission Spectrum 1.3 Photon Interactions with Matter: Photoelectric, Compton, Coherent & Pair Production
2 Subject 1, Chapter 2: Radiographic Equipment & Circuitry
2.1 High-Voltage Generators, Transformers & Rectification Circuits 2.2 Automatic Exposure Control (AEC), Beam Restriction & Quality Control 2.3 Tube Rating Charts, Extending Tube Life, Mechanical Malfunction & Preventive Maintenance
3 Subject 1, Chapter 3: Radiobiology & Cellular Response
3.1 Radiation Interaction with Tissue, Direct/Indirect Action & LET/RBE 3.2 Law of Bergonie & Tribondeau, Deterministic vs. Stochastic Effects 3.3 Dose-Response Relationships, Embryo and Fetal Effects & Acute Radiation Syndrome
4 Subject 1, Chapter 4: Radiation Protection & Dose Limits
4.1 ALARA Principles, Structural Shielding & Dose Limits 4.2 Personnel Dosimetry & Patient Dose Reduction Techniques 4.3 Dose Calculation Problems: Time, Distance, Shielding & Structural Barrier Design
5 Subject 1, Chapter 5: Imaging Informatics & Quality Assurance
5.1 PACS Architecture, DICOM Standards & HL7 Integration 5.2 Quality Assurance & Quality Control Protocols in Diagnostic Radiography 5.3 Radiology Workflow, RIS/HIS Integration, Teleradiology & Informatics Quality Assurance
6 Subject 2, Chapter 6: Film-Screen Radiography & Sensitometry
6.1 Film Emulsion, Latent Image Formation & Darkroom Chemistry 6.2 Sensitometric Curve (H&D Curve), Film Speed & Contrast Characteristics 6.3 Radiographic Film Analysis: Processing Faults, Handling Artifacts & Corrective Measures
7 Subject 2, Chapter 7: Technical Factors & Radiographic Quality
7.1 Density/Brightness, Contrast, Spatial Resolution & Distortion Controls 7.2 Exposure Math: Inverse Square Law, 15% Rule & Grid Conversion Factors 7.3 Technique Compensation: Age, Pathology, Cast and Orthopaedic Devices, Screen Speed & Beam Restriction
8 Subject 2, Chapter 8: Computed Radiography (CR)
8.1 Photostimulable Phosphor (PSP) Plates & CR Reader Mechanics 8.2 Image Processing, CR Artifacts & Erasure Protocols
9 Subject 2, Chapter 9: Digital Radiography (DR)
9.1 Flat-Panel Detectors: Direct vs. Indirect Conversion & TFT Arrays 9.2 Detective Quantum Efficiency (DQE), Modulation Transfer Function (MTF) & Dynamic Range
10 Subject 2, Chapter 10: Exposure Indicators & Image Evaluation
10.1 Exposure Indicators (S-Number, EI, DI), Windowing & Look-Up Tables (LUT) 10.2 Image Critique Checklist, Artifact Identification & Quality Control Standards 10.3 Image Display & Hard-Copy Output: Monitor Classification, DICOM GSDF, Dry vs Wet Laser Imaging
11 Subject 3, Chapter 11: Chest, Abdomen & Routine Positioning Concepts
11.1 Anatomical Terminology, Body Planes & Chest Radiography (PA, Lateral, Decubitus) 11.2 Abdominal Radiography: Acute Abdomen Series & Erect/Supine Protocols 11.3 Radiologic Surface Anatomy, Body Habitus & Sectional Body Cuts
12 Subject 3, Chapter 12: Upper & Lower Extremities & Girdles
12.1 Upper Limb & Shoulder Girdle Positioning (Hand, Wrist, Forearm, Elbow, Humerus, Shoulder) 12.2 Lower Limb & Pelvic Girdle Positioning (Foot, Ankle, Leg, Knee, Femur, Pelvis, Hip)
13 Subject 3, Chapter 13: Spine & Bony Thorax
13.1 Cervical, Thoracic & Lumbar Spine Radiography & Trauma Adaptations 13.2 Sacrum, Coccyx, Sacroiliac Joints & Bony Thorax (Ribs & Sternum)
14 Subject 3, Chapter 14: Cranium, Facial Bones & Paranasal Sinuses
14.1 Skull Positioning: Towne, Caldwell, Lateral & SMV Projections 14.2 Facial Bones, Orbits, Zygomatic Arches & Paranasal Sinuses
15 Subject 3, Chapter 15: Contrast Media Studies & Special Procedures
15.1 Gastrointestinal Contrast Procedures (Esophagram, UGI, Small Bowel, Barium Enema) 15.2 Genitourinary, Biliary & Special Fluoroscopic Studies (IVU, Cystography, ERCP, Myelography) 15.3 Reproductive System Studies: Hysterosalpingography, Pelvimetry & Male Reproductive Procedures 15.4 Nasopharyngography, Sialography & Fistulography / Sinus Tract Visualization
16 Subject 4, Chapter 16: Human Anatomy, Physiology & Pathology Integration
16.1 Body System Anatomy & Systemic Physiology Overview for Radiographers 16.2 Radiologic Pathology: Image Manifestations of Neoplastic, Inflammatory & Traumatic Conditions
17 Subject 4, Chapter 17: Patient Assessment, Communication & Informed Consent
17.1 Professional Communication, History Taking & Patient Rights 17.2 Informed Consent, Medical Documentation & Patient Transfer Safety
18 Subject 4, Chapter 18: Infection Control & Vital Signs Monitoring
18.1 Standard Precautions, Asepsis, Sterilization & Isolation Protocols 18.2 Measurement & Assessment of Vital Signs (BP, Pulse, Respiration, Temperature)
19 Subject 4, Chapter 19: Emergency Care & Aseptic Venipuncture
19.1 Basic Life Support (BLS), CPR Concepts & Emergency Response in Radiology 19.2 Aseptic Venipuncture Technique, IV Maintenance & Extravasation Care
20 Subject 4, Chapter 20: Professional Ethics, Jurisprudence & RA 7431
20.1 Republic Act No. 7431 (Radiologic Technology Act of 1992) & Board Rules 20.2 Code of Professional Ethics, Legal Liabilities, Malpractice & Negligence 20.3 Bioethical Principles in Practice, Professional Virtues & Interprofessional Relationships
21 Subject 5, Chapter 21: Diagnostic Ultrasonography
21.1 Ultrasound Physics, Transducer Construction & Doppler Principles 21.2 Acoustic Artifacts, Clinical Applications & Safety (TI/MI) 21.3 Clinical Ultrasound Examinations: Indications, Patient Preparation, Scanning Protocols & Transducer Selection
22 Subject 5, Chapter 22: Computed Tomography (CT)
22.1 CT Physics, Gantry Components, Detectors & Helical/Multislice Acquisition 22.2 Hounsfield Units, Windowing, CT Artifacts & Radiation Dose (CTDI/DLP)
23 Subject 5, Chapter 23: Magnetic Resonance Imaging (MRI)
23.1 MRI Physics, Nuclear Spin, T1/T2 Relaxation & Pulse Sequences 23.2 MRI Safety (Zones I-IV, SAR, Metallic Implants) & Common Artifacts 23.3 MRI Examination Protocols, Patient Preparation, Gadolinium Contrast & Sectional MRI Anatomy
24 Subject 5, Chapter 24: Interventional Radiology & Vascular Imaging
24.1 Vascular Access, Seldinger Technique & Digital Subtraction Angiography (DSA) 24.2 Interventional Procedures (Embolization, Angioplasty, Stenting) & C-Arm Radiation Safety 24.3 Interventional Patient Management: Contrast Selection, Pre-Procedure Workup & Post-Procedure Care
25 Subject 5, Chapter 25: Contrast Media Pharmacology & Adverse Reactions
25.1 Classification of Contrast Agents: Osmolality, Viscosity & Iodine Concentration 25.2 Adverse Contrast Reactions (Mild, Moderate, Severe) & Emergency Treatment Protocols 25.3 General Pharmacologic Principles: Pharmacokinetics, Pharmacodynamics, Drug Categories & the Rights of Drug Safety
26 Subject 5, Chapter 26: Nuclear Medicine & Molecular Imaging
26.1 Radioisotopes, Radiopharmaceuticals & Gamma Camera / SPECT Operation 26.2 Positron Emission Tomography (PET/CT) & Unsealed Radiation Source Safety
27 Subject 5, Chapter 27: Radiation Therapy & Radiation Oncology
27.1 Principles of Radiation Oncology, Linear Accelerators & Treatment Planning 27.2 Teletherapy vs. Brachytherapy, Patient Immobilization & Side Effect Management 27.3 Isodose Planning, Treatment Delivery Methods & Radiobiologic Principles in Radiation Therapy
28 Mammography & Dental Radiography
28.1 Mammography: Equipment, CC and MLO Positioning, Compression & Breast Pathology 28.2 Dental Radiography: Paralleling and Bisecting Techniques, Bitewing, Occlusal, Panoramic & Cephalometric
29 Medical Terminology for Radiologic Technology
29.1 Medical Word Building: Root Words, Combining Forms, Prefixes & Suffixes 29.2 Medical Terms in General Medicine, Abbreviations, Symbols & Critiquing Requests and Reports
30 Radiology Administration, Organization & Leadership
30.1 Organizational Structure, Staffing & Licensing Requirements of a Radiology Facility 30.2 Radiology Department Management: Job Descriptions, Duties, Leadership Styles & Entrepreneurial Skills
3.3 Dose-Response Relationships, Embryo and Fetal Effects & Acute Radiation Syndrome
Key Takeaways Explain This Topic AI
Radiation protection standards are built on the linear no-threshold model, in which any dose carries some probability of a stochastic effect; deterministic (tissue-reaction) effects instead follow a non-linear threshold curve.
The three periods of in-utero radiosensitivity are pre-implantation (0-9 days, prenatal death), major organogenesis (10 days-6 weeks, congenital malformation and neonatal death), and the fetal period (6 weeks-term, growth restriction and reduced IQ, with peak central nervous system sensitivity at 8-15 weeks).
The three acute radiation syndromes are haematopoietic (roughly 1-10 Gy), gastrointestinal (roughly 6-10 Gy and above), and cerebrovascular (above roughly 50 Gy), and every one of them passes through prodromal, latent, manifest illness and recovery-or-death stages.
LD 50/60 for whole-body human exposure without medical support is approximately 3.5 Gy, and about 5-6 Gy with supportive care; diagnostic radiography never approaches these levels.
Diagnostic examinations deliver fetal doses far below the roughly 100-150 mGy threshold at which any measurable increase in malformation risk is discussed, so the correct response to an inadvertent exposure in early pregnancy is dose estimation and counselling, never automatic termination.
Last updated: August 2026
3.3 Dose-Response Relationships, Embryo and Fetal Effects & Acute Radiation Syndrome
The Enhanced TOS gives Dose Response Relationships 7 items and splits them into two competencies: construct the concepts of embryo and fetal effects of radiation exposure and acute radiation syndromes , and make use of dose-response curves to study the relationship between radiation dose levels and the degree of biologic response . Both are moderate-to-difficult Bloom levels, so expect applied scenarios rather than recall.
1. Reading a Dose-Response Curve
A radiation dose-response relationship is a graph with dose on the horizontal axis and observed biologic response on the vertical axis . Curves are classified along two axes: linear versus non-linear, and threshold versus non-threshold.
Curve type Shape Threshold? What it models
Linear, non-threshold (LNT) Straight line through the origin No — any dose has some risk Stochastic effects: cancer induction and heritable genetic effects
Linear, threshold Straight line intersecting the dose axis at a threshold Yes Some tissue reactions modelled linearly above threshold
Non-linear (sigmoid), threshold S-shaped curve beginning at a threshold dose Yes Deterministic effects: skin erythema, epilation, cataract, sterility, haematologic depression
Non-linear, non-threshold Curved through the origin No Historically used for some leukaemia data sets
Why LNT governs radiation protection. The data that define stochastic risk come from high-dose populations — the Japanese atomic-bomb survivors, early radiologists, radium dial painters, patients irradiated for ankylosing spondylitis and tinea capitis. At the very low doses of diagnostic imaging, the excess risk is too small to measure directly against the natural cancer background. Protection agencies therefore extrapolate the high-dose line back through the origin and assume no safe threshold. This is deliberately conservative : it may overestimate low-dose risk, but it is the assumption that justifies ALARA, dose limits, shielding, and the whole apparatus of radiation protection. An examination item that says "LNT is proven at diagnostic doses" is wrong; the correct framing is that it is an assumed, protective, extrapolated model.
Contrast with the deterministic curve. A sigmoid threshold curve has three regions: below threshold nothing happens; above threshold severity rises steeply with dose; at high dose the response saturates because every cell that can respond already has. Deterministic effects are characterised by a threshold dose and by severity that increases with dose , whereas stochastic effects have no threshold and a probability — not a severity — that increases with dose.
- Feature Stochastic Deterministic (tissue reaction)
- Threshold None assumed Yes
- What dose changes Probability of occurrence Severity of the effect
Examples Cancer, heritable genetic effects Erythema, epilation, cataract, sterility, fibrosis, bone marrow depression
Relevance to diagnostic radiography The main concern Only in prolonged fluoroscopy and interventional procedures
2. Embryo and Fetal Effects
This is examined every administration, and Philippine practice guidance mirrors international consensus.
The three periods of gestation
Period Gestational age Dominant radiation effect Comment
Pre-implantation 0-9 days after conception Prenatal (embryonic) death The classic "all-or-nothing" period — the conceptus either dies and is resorbed, often before a missed period, or develops normally
Major organogenesis 10 days to 6 weeks Congenital malformation and neonatal death Highest risk of structural anomaly, because organ primordia are differentiating; skeletal, ocular, genital and CNS anomalies predominate
Fetal (growth) period 6 weeks to term Growth restriction , reduced IQ , childhood malignancy Structural malformation risk falls sharply; functional and growth effects dominate
Peak central nervous system sensitivity is 8 to 15 weeks , when neuronal proliferation and migration are most intense; a secondary, less sensitive window runs 16 to 25 weeks. Outside 8 to 25 weeks, measurable IQ effects have not been demonstrated even at doses well above diagnostic levels.
Putting diagnostic doses in perspective
- Situation Approximate fetal dose
- Chest radiograph (PA and lateral) Well under 0.01 mGy — the uterus is outside the primary beam
- Extremity, skull or dental radiography Effectively zero fetal dose with collimation
- Abdomen or pelvis radiograph Roughly 1-3 mGy
- Intravenous urography Roughly 2-10 mGy
- Barium enema Roughly 5-20 mGy
- CT of the abdomen or pelvis Roughly 10-50 mGy
- Natural background over nine months Roughly 0.5-1 mGy
The dose level at which any increase in malformation risk is even discussed is around 100-150 mGy . Essentially no single diagnostic radiographic examination reaches it. The professionally correct response to an inadvertent exposure in early pregnancy is therefore: document the examination, obtain a dose estimate from the medical physicist, and counsel the patient with real numbers. Recommending termination on the basis of a diagnostic radiograph is both scientifically unsupportable and, in the Philippine legal and ethical context, indefensible.
Practical protection rules
Ask every female patient of childbearing age about the possibility of pregnancy, and document the answer.
Use the elective booking rule — schedule non-urgent abdominal and pelvic examinations during the first 10 days after the onset of menstruation where clinically reasonable.
Post pregnancy-enquiry signage in the waiting and changing areas.
Never withhold a clinically necessary examination on a pregnant patient when the mother's condition demands it; optimise instead — tight collimation, high kVp with low mAs, and shielding outside the primary field where it does not compromise the examination.
A declared pregnant worker should be managed with a lower dose constraint and a second dosimeter worn at waist level under the apron.
3. Acute Radiation Syndrome
ARS follows a whole-body , high-dose , short-duration exposure to penetrating radiation. It never arises from diagnostic radiography; it is examined because it demonstrates the deterministic dose-response principle and because radiologic technologists may be first responders in a radiation accident.
The four stages present in every syndrome
Prodromal stage. Onset within minutes to hours. Nausea, vomiting, diarrhoea, malaise, fatigue. The shorter the interval to vomiting, the higher the dose — vomiting within one hour suggests a dose above roughly 4 Gy and is the single most useful bedside triage sign.
Latent stage. A deceptive period of apparent wellness lasting hours to weeks. It is longest at low doses and shortest at high doses , disappearing entirely in the cerebrovascular form.
Manifest illness stage. The syndrome-specific clinical picture appears.
Recovery or death.
The three syndromes
Syndrome Approximate whole-body dose Target tissue Manifest illness Time to death if fatal
Haematopoietic (bone marrow) About 1-10 Gy Bone marrow stem cells Lymphopenia first, then neutropenia, thrombocytopenia and anaemia; infection and haemorrhage Weeks to about 2 months
Gastrointestinal About 6-10 Gy and above Intestinal crypt cells Denuded intestinal villi, intractable diarrhoea, fluid and electrolyte loss, sepsis Roughly 3-10 days
Cerebrovascular (central nervous system) Above about 50 Gy Vasculature and neurons Immediate severe vomiting, ataxia, disorientation, seizures, coma, cerebral oedema Hours to about 3 days
Lymphocytes are the most radiosensitive circulating cell , so a serial absolute lymphocyte count over the first 48 hours is the standard biological dosimeter in a suspected exposure.
Lethal dose
LD 50/60 — the whole-body dose expected to kill 50% of an exposed human population within 60 days — is approximately 3.5 Gy without medical support , rising to roughly 5-6 Gy with aggressive supportive care (reverse isolation, antibiotics, transfusion, growth factors). Older textbooks quote LD 50/30; be alert to which the item asks for.
4. Scenario Practice
Scenario Correct reasoning
A patient reports she may be 5 weeks pregnant and needs a wrist radiograph after a fall Proceed. The uterus is far outside the primary beam; collimate tightly and document the pregnancy enquiry.
A trauma patient with a positive pregnancy test requires an urgent CT of the abdomen for suspected haemorrhage Proceed — maternal life takes precedence. Optimise the protocol and involve the radiologist and medical physicist for a dose estimate.
A worker in a radiation accident vomits 30 minutes after the event A very short prodromal interval implies a high dose, likely above 4 Gy. Obtain serial lymphocyte counts immediately.
An item asks which curve justifies ALARA at diagnostic doses The linear non-threshold curve, extrapolated from high-dose human data, assuming no safe threshold.
An item asks why severity, not probability, rises with dose for cataract Cataract is a deterministic tissue reaction with a threshold; above it, severity scales with dose.