Study guide

7.3 Technique Compensation: Age, Pathology, Cast and Orthopaedic Devices, Screen Speed & Beam Restriction

Philippine Radiologic Technologists Licensure Examination Exam

Track your progress as you read

Finished sections get a check mark.

1 Subject 1, Chapter 1: Physics of Radiology & X-Ray Production

1.1 Atomic Structure, Electromagnetic Spectrum & X-Ray Production Mechanisms 1.2 X-Ray Tube Components, Target Interactions & Emission Spectrum 1.3 Photon Interactions with Matter: Photoelectric, Compton, Coherent & Pair Production

2 Subject 1, Chapter 2: Radiographic Equipment & Circuitry

2.1 High-Voltage Generators, Transformers & Rectification Circuits 2.2 Automatic Exposure Control (AEC), Beam Restriction & Quality Control 2.3 Tube Rating Charts, Extending Tube Life, Mechanical Malfunction & Preventive Maintenance

3 Subject 1, Chapter 3: Radiobiology & Cellular Response

3.1 Radiation Interaction with Tissue, Direct/Indirect Action & LET/RBE 3.2 Law of Bergonie & Tribondeau, Deterministic vs. Stochastic Effects 3.3 Dose-Response Relationships, Embryo and Fetal Effects & Acute Radiation Syndrome

4 Subject 1, Chapter 4: Radiation Protection & Dose Limits

4.1 ALARA Principles, Structural Shielding & Dose Limits 4.2 Personnel Dosimetry & Patient Dose Reduction Techniques 4.3 Dose Calculation Problems: Time, Distance, Shielding & Structural Barrier Design

5 Subject 1, Chapter 5: Imaging Informatics & Quality Assurance

5.1 PACS Architecture, DICOM Standards & HL7 Integration 5.2 Quality Assurance & Quality Control Protocols in Diagnostic Radiography 5.3 Radiology Workflow, RIS/HIS Integration, Teleradiology & Informatics Quality Assurance

6 Subject 2, Chapter 6: Film-Screen Radiography & Sensitometry

6.1 Film Emulsion, Latent Image Formation & Darkroom Chemistry 6.2 Sensitometric Curve (H&D Curve), Film Speed & Contrast Characteristics 6.3 Radiographic Film Analysis: Processing Faults, Handling Artifacts & Corrective Measures

7 Subject 2, Chapter 7: Technical Factors & Radiographic Quality

7.1 Density/Brightness, Contrast, Spatial Resolution & Distortion Controls 7.2 Exposure Math: Inverse Square Law, 15% Rule & Grid Conversion Factors 7.3 Technique Compensation: Age, Pathology, Cast and Orthopaedic Devices, Screen Speed & Beam Restriction

8 Subject 2, Chapter 8: Computed Radiography (CR)

8.1 Photostimulable Phosphor (PSP) Plates & CR Reader Mechanics 8.2 Image Processing, CR Artifacts & Erasure Protocols

9 Subject 2, Chapter 9: Digital Radiography (DR)

9.1 Flat-Panel Detectors: Direct vs. Indirect Conversion & TFT Arrays 9.2 Detective Quantum Efficiency (DQE), Modulation Transfer Function (MTF) & Dynamic Range

10 Subject 2, Chapter 10: Exposure Indicators & Image Evaluation

10.1 Exposure Indicators (S-Number, EI, DI), Windowing & Look-Up Tables (LUT) 10.2 Image Critique Checklist, Artifact Identification & Quality Control Standards 10.3 Image Display & Hard-Copy Output: Monitor Classification, DICOM GSDF, Dry vs Wet Laser Imaging

11 Subject 3, Chapter 11: Chest, Abdomen & Routine Positioning Concepts

11.1 Anatomical Terminology, Body Planes & Chest Radiography (PA, Lateral, Decubitus) 11.2 Abdominal Radiography: Acute Abdomen Series & Erect/Supine Protocols 11.3 Radiologic Surface Anatomy, Body Habitus & Sectional Body Cuts

12 Subject 3, Chapter 12: Upper & Lower Extremities & Girdles

12.1 Upper Limb & Shoulder Girdle Positioning (Hand, Wrist, Forearm, Elbow, Humerus, Shoulder) 12.2 Lower Limb & Pelvic Girdle Positioning (Foot, Ankle, Leg, Knee, Femur, Pelvis, Hip)

13 Subject 3, Chapter 13: Spine & Bony Thorax

13.1 Cervical, Thoracic & Lumbar Spine Radiography & Trauma Adaptations 13.2 Sacrum, Coccyx, Sacroiliac Joints & Bony Thorax (Ribs & Sternum)

14 Subject 3, Chapter 14: Cranium, Facial Bones & Paranasal Sinuses

14.1 Skull Positioning: Towne, Caldwell, Lateral & SMV Projections 14.2 Facial Bones, Orbits, Zygomatic Arches & Paranasal Sinuses

15 Subject 3, Chapter 15: Contrast Media Studies & Special Procedures

15.1 Gastrointestinal Contrast Procedures (Esophagram, UGI, Small Bowel, Barium Enema) 15.2 Genitourinary, Biliary & Special Fluoroscopic Studies (IVU, Cystography, ERCP, Myelography) 15.3 Reproductive System Studies: Hysterosalpingography, Pelvimetry & Male Reproductive Procedures 15.4 Nasopharyngography, Sialography & Fistulography / Sinus Tract Visualization

16 Subject 4, Chapter 16: Human Anatomy, Physiology & Pathology Integration

16.1 Body System Anatomy & Systemic Physiology Overview for Radiographers 16.2 Radiologic Pathology: Image Manifestations of Neoplastic, Inflammatory & Traumatic Conditions

17 Subject 4, Chapter 17: Patient Assessment, Communication & Informed Consent

17.1 Professional Communication, History Taking & Patient Rights 17.2 Informed Consent, Medical Documentation & Patient Transfer Safety

18 Subject 4, Chapter 18: Infection Control & Vital Signs Monitoring

18.1 Standard Precautions, Asepsis, Sterilization & Isolation Protocols 18.2 Measurement & Assessment of Vital Signs (BP, Pulse, Respiration, Temperature)

19 Subject 4, Chapter 19: Emergency Care & Aseptic Venipuncture

19.1 Basic Life Support (BLS), CPR Concepts & Emergency Response in Radiology 19.2 Aseptic Venipuncture Technique, IV Maintenance & Extravasation Care

20 Subject 4, Chapter 20: Professional Ethics, Jurisprudence & RA 7431

20.1 Republic Act No. 7431 (Radiologic Technology Act of 1992) & Board Rules 20.2 Code of Professional Ethics, Legal Liabilities, Malpractice & Negligence 20.3 Bioethical Principles in Practice, Professional Virtues & Interprofessional Relationships

21 Subject 5, Chapter 21: Diagnostic Ultrasonography

21.1 Ultrasound Physics, Transducer Construction & Doppler Principles 21.2 Acoustic Artifacts, Clinical Applications & Safety (TI/MI) 21.3 Clinical Ultrasound Examinations: Indications, Patient Preparation, Scanning Protocols & Transducer Selection

22 Subject 5, Chapter 22: Computed Tomography (CT)

22.1 CT Physics, Gantry Components, Detectors & Helical/Multislice Acquisition 22.2 Hounsfield Units, Windowing, CT Artifacts & Radiation Dose (CTDI/DLP)

23 Subject 5, Chapter 23: Magnetic Resonance Imaging (MRI)

23.1 MRI Physics, Nuclear Spin, T1/T2 Relaxation & Pulse Sequences 23.2 MRI Safety (Zones I-IV, SAR, Metallic Implants) & Common Artifacts 23.3 MRI Examination Protocols, Patient Preparation, Gadolinium Contrast & Sectional MRI Anatomy

24 Subject 5, Chapter 24: Interventional Radiology & Vascular Imaging

24.1 Vascular Access, Seldinger Technique & Digital Subtraction Angiography (DSA) 24.2 Interventional Procedures (Embolization, Angioplasty, Stenting) & C-Arm Radiation Safety 24.3 Interventional Patient Management: Contrast Selection, Pre-Procedure Workup & Post-Procedure Care

25 Subject 5, Chapter 25: Contrast Media Pharmacology & Adverse Reactions

25.1 Classification of Contrast Agents: Osmolality, Viscosity & Iodine Concentration 25.2 Adverse Contrast Reactions (Mild, Moderate, Severe) & Emergency Treatment Protocols 25.3 General Pharmacologic Principles: Pharmacokinetics, Pharmacodynamics, Drug Categories & the Rights of Drug Safety

26 Subject 5, Chapter 26: Nuclear Medicine & Molecular Imaging

26.1 Radioisotopes, Radiopharmaceuticals & Gamma Camera / SPECT Operation 26.2 Positron Emission Tomography (PET/CT) & Unsealed Radiation Source Safety

27 Subject 5, Chapter 27: Radiation Therapy & Radiation Oncology

27.1 Principles of Radiation Oncology, Linear Accelerators & Treatment Planning 27.2 Teletherapy vs. Brachytherapy, Patient Immobilization & Side Effect Management 27.3 Isodose Planning, Treatment Delivery Methods & Radiobiologic Principles in Radiation Therapy

28 Mammography & Dental Radiography

28.1 Mammography: Equipment, CC and MLO Positioning, Compression & Breast Pathology 28.2 Dental Radiography: Paralleling and Bisecting Techniques, Bitewing, Occlusal, Panoramic & Cephalometric

29 Medical Terminology for Radiologic Technology

29.1 Medical Word Building: Root Words, Combining Forms, Prefixes & Suffixes 29.2 Medical Terms in General Medicine, Abbreviations, Symbols & Critiquing Requests and Reports

30 Radiology Administration, Organization & Leadership

30.1 Organizational Structure, Staffing & Licensing Requirements of a Radiology Facility 30.2 Radiology Department Management: Job Descriptions, Duties, Leadership Styles & Entrepreneurial Skills

7.3 Technique Compensation: Age, Pathology, Cast and Orthopaedic Devices, Screen Speed & Beam Restriction

Key Takeaways Explain This Topic AI

Paediatric technique reduces mAs substantially below the adult value for the same part while keeping exposure times as short as possible, and geriatric technique reduces mAs for osteoporotic bone but often needs longer immobilisation support rather than higher factors.

A dry plaster cast typically requires doubling the mAs or adding about 8 to 10 kVp, a wet plaster cast requires roughly tripling the mAs, and a fibreglass cast requires only about a 25 to 30 percent mAs increase or no change at all.

Additive pathology such as pleural effusion, ascites, pneumonia, Paget disease and osteoblastic metastasis requires an increase in technique, while destructive pathology such as emphysema, osteoporosis, osteolytic metastasis and bowel obstruction requires a decrease.

Changing intensifying screen speed follows the relative speed formula, in which the new mAs equals the old mAs times the old relative speed divided by the new relative speed, so moving from 200 to 400 speed halves the required mAs.

Adding or tightening a beam restrictor removes scatter and therefore reduces receptor exposure, requiring a compensating increase in mAs; the general rule for changing from a large to a small field is roughly a 30 to 50 percent mAs increase.

Last updated: August 2026

7.3 Technique Compensation: Age, Pathology, Cast and Orthopaedic Devices, Screen Speed & Beam Restriction

Section 7.2 covered the inverse square law, the 15% rule and grid conversion factors. The Enhanced TOS competency 2.3 of Radiographic Contrast lists eight conversion situations and awards 5 items to solving them. The remaining four — technique change when using a beam restrictor, correction factor for varying intensifying screen speeds, age correction factor, and correction factor for orthopaedic radiography — are the subject of this section, together with the pathology compensation that examiners pair with them.

1. The Master Rule

Every compensation question is the same question: something has changed how many photons reach the image receptor, so how much must mAs change to restore receptor exposure?

If the change removes photons from the receptor (thicker part, tighter collimation, adding a grid, slower screen, wet cast), increase mAs.

If the change delivers more photons (faster screen, removing a grid, thinner or less dense part), decrease mAs.

Adjust mAs , not kVp, when your goal is to restore density or receptor exposure while holding contrast constant. Adjust kVp when you need penetration.

2. Age Correction

Age changes tissue composition, not just size, so a paediatric or geriatric patient is not simply "a smaller adult".

Paediatric

  • Age band Typical mAs relative to the adult value for the same part Rationale
  • Neonate / infant About 25-30% Minimal muscle mass, high water content, poorly mineralised bone
  • 1-5 years About 30-50% Progressive mineralisation
  • 6-12 years About 50-75% Approaching adult tissue density
  • Adolescent Approaching 100% Adult technique with size adjustment

Beyond arithmetic, paediatric technique obeys three rules:

Shortest possible exposure time , achieved with the highest mA the tube allows, because motion is the dominant cause of repeats in children.

Higher kVp with lower mAs where contrast permits, to cut dose.

Immobilisation before restraint. Use the department's approved immobilisation devices; a parent or guardian who assists must be given a lead apron and gloves and must never be someone who is or may be pregnant.

Geriatric

Osteoporotic bone attenuates less, so reduce mAs by roughly 25-30% for the spine, pelvis and hip in a patient with known significant osteoporosis. What geriatric patients usually need is not a technique change but time, support and clear instruction : kyphosis alters the relationship between the part and the receptor, hearing impairment affects breathing instructions, and reduced mobility limits positioning. Compensating with technique for a poorly supported position produces motion, not diagnosis.

3. Casts and Orthopaedic Devices

This is the "correction factor for orthopaedic radiography" the TOS names explicitly.

  • Device Compensation
  • Fibreglass cast No change , or increase mAs by about 25-30% for a thick cast
  • Dry plaster cast (small to medium) Double the mAs , or add about 8-10 kVp
  • Dry plaster cast (large / hip spica) Increase mAs by about 2 to 3 times , or add about 10 kVp

Wet plaster cast Increase mAs by about 3 times , or add about 10-12 kVp — water in the plaster is a major additional attenuator

Plaster cast with a metal reinforcing bar Do not compensate for the bar; change the projection if it obscures anatomy

  • Air splint Decrease mAs slightly — the splint attenuates less than the soft tissue it replaces
  • Fibreglass or plastic splint Usually no change

Orthopaedic hardware (plates, rods, prostheses) Do not increase overall technique to "see through" metal. Metal is essentially opaque; instead collimate, use an appropriate projection, and consider metal-artifact strategies on cross-sectional imaging

A recurring exam trap: traction apparatus and external fixators do not require a technique increase — they require a projection that works around them, plus scrupulous attention to not moving the limb.

4. Pathology Compensation

The Patient Care subject links this to Effect of Pathologic Conditions on the Relative Attenuation of X-rays ; the Image Production subject tests the arithmetic.

Direction Mechanism Examples Typical adjustment

Additive (increase technique) Fluid, tissue or mineral replaces air, or bone becomes denser Pleural effusion, empyema, haemothorax, ascites, pneumonia, atelectasis, pulmonary oedema, congestive heart failure, Paget disease, osteoblastic metastasis, osteopetrosis, acromegaly, hydrocephalus Increase mAs by about 35-50% , or add about 5-8 kVp (more for large effusions)

Destructive (decrease technique) Air or lucent tissue replaces denser tissue, or bone demineralises Emphysema, pneumothorax, bowel obstruction, free intraperitoneal air, osteoporosis, osteomalacia, osteolytic metastasis, multiple myeloma, degenerative arthritis in the elderly, severe emaciation Decrease mAs by about 25-50% , or reduce kVp by about 5-8

The judgement rule: compensate only when the pathology is known and diffuse . A focal lesion should never drive a global technique change, and compensating for a suspected but unconfirmed condition risks masking the very finding being sought.

  • 5. Intensifying Screen Speed Conversion
  • new mAs = old mAs x (old relative speed / new relative speed)
  • Screen system Relative speed
  • Detail / extremity (slow) 100
  • Par speed 200
  • Regular / medium 400
  • High speed 800
  • Very high speed 1200

Worked example 1. An acceptable knee radiograph used 20 mAs with a 100-speed detail screen. What mAs is needed on a 400-speed system?

20 x (100 / 400) = 5 mAs . Four times faster means one quarter the mAs.

Worked example 2. A technologist must move from a 400-speed system to a 100-speed detail cassette for a finger. Original technique was 3 mAs.

3 x (400 / 100) = 12 mAs .

The trade-off you must be able to state. Faster screens use larger phosphor crystals and a thicker phosphor layer, which increases light output and therefore lowers patient dose , but increases quantum mottle and light diffusion , which degrades spatial resolution (recorded detail) . Slow detail screens are used for extremities precisely because resolution matters more than dose in a thin, low-dose part.

Screen-film relative speed also depends on kVp: rare-earth screen speed rises with kVp, so a technique chart calibrated at 70 kVp may over-expose at 100 kVp on the same system.

6. Beam-Restrictor (Collimation) Change

Tightening collimation removes scattered photons that were contributing to receptor exposure. The image gets cleaner but lighter , so mAs must rise.

  • Field change Typical mAs compensation
  • Large field to a moderately smaller field Increase mAs by about 30%

Large field to a tightly collimated small field on a thick part Increase mAs by about 50% , or more on the abdomen and lumbar spine

Removing a cone or restrictor (opening the field) Decrease mAs correspondingly

The magnitude scales with the amount of scatter that was present : on a thin extremity, collimating changes almost nothing; on a large abdomen at 80 kVp, it can change receptor exposure substantially. Never let this compensation become an argument against collimating — collimation is the primary scatter-control and dose-reduction tool, and modern automatic exposure control largely handles the compensation for you provided the correct chamber is selected.

7. Consolidated Conversion Reference

  • Situation Formula or factor
  • Distance change (maintain density) new mAs = old mAs x (new SID squared / old SID squared)
  • 15% rule (maintain density) Increase kVp by 15% and halve mAs; decrease kVp by 15% and double mAs

Grid change new mAs = old mAs x (new grid factor / old grid factor) ; typical factors: no grid 1, 5:1 grid 2, 6:1 grid 3, 8:1 grid 4, 12:1 grid 5, 16:1 grid 6

  • Screen speed change new mAs = old mAs x (old speed / new speed)
  • Dry plaster cast mAs x 2, or kVp + 8 to 10
  • Wet plaster cast mAs x 3, or kVp + 10 to 12
  • Fibreglass cast mAs x 1.25 to 1.3, or no change
  • Additive pathology mAs x 1.35 to 1.5, or kVp + 5 to 8
  • Destructive pathology mAs x 0.5 to 0.75, or kVp - 5 to 8
  • Paediatric (infant) About 25-30% of adult mAs
  • Tighter collimation mAs x 1.3 to 1.5

Worked composite example. An adult knee is imaged at 65 kVp, 8 mAs, 100 cm SID, 400-speed screens, no grid. The next patient is an adult in a dry plaster long-leg cast , and the department has only 100-speed detail cassettes left.

Cast: 8 x 2 = 16 mAs .

Screen speed: 16 x (400 / 100) = 64 mAs .

Final technique: 65 kVp, 64 mAs at 100 cm SID . If 64 mAs forces an exposure time long enough to risk motion, apply the 15% rule instead — raise to about 75 kVp and halve the mAs to 32 — accepting the slight loss of contrast in exchange for a motion-free image.