Study guide

5.2 Specimen Processing & Quality Assurance

CPT Certified Phlebotomy Technician Exam Exam

Track your progress as you read

Finished sections get a check mark.

1 Introduction: CPT Phlebotomy Exam Overview

NHA CPT Exam Overview CPT Certification Process Anatomy & Physiology for Phlebotomists

2 Chapter 1: Safety & Compliance (26%)

1.1 Infection Control & Personal Protective Equipment (PPE) 1.2 OSHA Regulations & Workplace Safety

3 Chapter 2: Patient Preparation & Identification (20%)

2.1 Patient Identification & Communication 2.2 Patient Preparation & Positioning

4 Chapter 3: Venipuncture Procedures (Routine Blood Collections, 28%)

3.1 Venipuncture Equipment & Technique 3.2 Order of Draw 3.3 Difficult Draws & Complications

5 Chapter 4: Capillary Puncture (Routine Blood Collections) & Special Collections (12%)

4.1 Capillary (Dermal) Puncture Technique 4.2 Special Collection Procedures

6 Chapter 5: Specimen Handling & Processing (14%)

5.1 Specimen Labeling & Transport 5.2 Specimen Processing & Quality Assurance

5.2 Specimen Processing & Quality Assurance

Key Takeaways Explain This Topic AI

Centrifugation separates blood into its components — serum (from clotted blood) or plasma (from anticoagulated blood) is separated from cells

Serum separator tubes (SST/gold top) must clot for 30 minutes at room temperature before centrifugation; plain red tops require 60 minutes

Aliquoting is the process of transferring separated serum or plasma to a secondary tube for testing or storage

Common specimen rejection criteria include: hemolysis, lipemia, clotted anticoagulated specimens, wrong tube type, insufficient volume, and expired tubes

Quality assurance (QA) is a comprehensive program ensuring the entire testing process produces reliable results — includes preanalytical, analytical, and postanalytical phases

Delta checks compare a patient's current test results with their previous results to identify potential errors or significant clinical changes

The most common preanalytical errors are: patient misidentification, hemolyzed specimens, clotted anticoagulated specimens, and incorrect tube selection

Lab requisition forms must include: patient name, DOB/MRN, ordering physician, tests requested, date/time ordered, diagnosis/ICD code, and specimen source

Last updated: February 2026

Specimen processing is the bridge between collection and laboratory analysis. Proper processing techniques ensure the integrity of the specimen and the accuracy of test results. Quality assurance programs provide systematic oversight of the entire testing process.

Centrifugation

Centrifugation uses centrifugal force to separate blood into its components based on density. The heavier cellular components (RBCs, WBCs, platelets) settle to the bottom, while the lighter liquid component (serum or plasma) rises to the top.

Serum vs. Plasma

Type Source Tube Contains Fibrinogen? Clotting Required?

Serum Clotted blood Red top, Gold SST No (consumed during clotting) Yes — must clot before centrifuging

Plasma Anticoagulated blood Green (heparin), Lavender (EDTA), Light blue (citrate) Yes (fibrinogen preserved) No — anticoagulant prevents clotting

Clotting Times Before Centrifugation

  • Tube Type Clotting Time Reason
  • Gold SST (clot activator + gel) 30 minutes at room temperature Clot activator accelerates clotting
  • Red top (no additive) 60 minutes at room temperature No clot activator; natural clotting process takes longer

Anticoagulated tubes (green, lavender, light blue) No clotting time — centrifuge immediately if needed Anticoagulant prevents clotting

  • Centrifugation Guidelines
  • Standard speed: 1,000-2,000 x g (relative centrifugal force) for 10-15 minutes
  • Ensure the centrifuge is properly balanced (equal tube weights on opposite sides)
  • Never open the centrifuge lid while it is spinning
  • After centrifugation, the gel separator in SST tubes forms a barrier between serum and cells
  • Aliquoting

Aliquoting is the process of transferring separated serum or plasma from the original tube to a secondary (aliquot) tube:

  • Use a disposable transfer pipette — never pour from one tube to another
  • Label the aliquot tube with the same patient information as the original

Aliquoting is performed when:

  • Multiple departments need the same specimen
  • The specimen must be stored or frozen for later testing
  • A send-out laboratory requires a specific container
  • Avoid transferring any cells or gel into the aliquot tube
  • Serum vs. Plasma — Understanding the Difference

This is a commonly tested concept on the NHA CPT exam:

  • Serum
  • Produced from clotted blood (red top, gold SST)
  • Blood is allowed to clot, then centrifuged
  • Does NOT contain fibrinogen or clotting factors (they were consumed during clotting)
  • Appears as a clear, straw-yellow liquid above the clot
  • Used for most chemistry tests, serology, and immunology
  • Plasma
  • Produced from anticoagulated blood (green, lavender, light blue)
  • Blood is prevented from clotting by the anticoagulant
  • DOES contain fibrinogen and clotting factors
  • Appears as a clear, straw-yellow liquid above the packed cells
  • Used for coagulation tests, stat chemistry, some immunology tests
  • Key Differences at a Glance
  • Feature Serum Plasma
  • Clotting Blood must clot first Clotting is prevented
  • Fibrinogen Absent (consumed) Present
  • Tube types Red, gold SST Green, lavender, light blue
  • Processing time Longer (30-60 min clotting + centrifuge) Shorter (centrifuge immediately)
  • Gel separator Gold SST Green/gray PST (plasma separator tube)
  • Common tests BMP, CMP, lipid panel, thyroid PT/INR, PTT, stat electrolytes, CBC plasma
  • Specimen Integrity Indicators

Modern laboratory analyzers can detect specimen quality issues automatically:

  • Indicator Abbreviation Appearance Cause
  • Hemolysis H Pink to red serum/plasma RBC destruction
  • Icterus I Deep yellow/orange serum/plasma Elevated bilirubin (jaundice)
  • Lipemia L Milky/turbid serum/plasma Elevated triglycerides (non-fasting)

These indicators (collectively called the HIL index ) are reported with test results when they may affect accuracy. The laboratory may request a recollection if interference is significant.

Specimen Rejection Criteria

Laboratories reject specimens that do not meet quality standards. Common rejection reasons:

Reason for Rejection Description Prevention

Hemolysis Pink/red serum or plasma (ruptured RBCs) — #1 cause of rejection Proper technique: correct gauge, don't shake, allow alcohol to dry

Lipemia Milky/turbid serum (high fat content) Ensure proper fasting; note non-fasting on label

Clotted anticoagulated specimen Clots in EDTA, citrate, or heparin tubes Mix tubes immediately by inversion; check for proper fill

Wrong tube type Test ordered requires a different tube than what was collected Verify order of draw and tube selection before drawing

Insufficient volume Not enough blood for the test (especially critical for citrate tubes) Ensure proper tube fill; redraw if underfilled

Expired tubes Tubes past their expiration date may have degraded vacuum or additives Check expiration dates before use

Mislabeled or unlabeled Cannot confirm patient identity Label at bedside; use two identifiers

Improper transport Wrong temperature, excessive delay, broken tube Follow transport protocols for each specimen type

QNS (Quantity Not Sufficient) Sample volume too low to perform the requested test Collect adequate volume; check tube fill

Laboratory Test Panels

Phlebotomists should be familiar with common test panels (groups of tests ordered together):

Basic Metabolic Panel (BMP) — 8 Tests

  • Test Tube What It Measures
  • Glucose Gold SST or Gray Blood sugar level
  • BUN (Blood Urea Nitrogen) Gold SST Kidney function
  • Creatinine Gold SST Kidney function
  • Sodium (Na+) Gold SST Electrolyte balance
  • Potassium (K+) Gold SST Electrolyte balance
  • Chloride (Cl-) Gold SST Electrolyte balance
  • CO2 (Bicarbonate) Gold SST Acid-base balance
  • Calcium Gold SST Bone/metabolic function
  • Comprehensive Metabolic Panel (CMP) — 14 Tests

All 8 BMP tests PLUS:

  • Albumin, total protein, alkaline phosphatase (ALP), ALT, AST, and total bilirubin
  • Assesses liver function in addition to kidney function and electrolytes
  • Complete Blood Count (CBC)
  • Test Tube What It Measures
  • WBC (White Blood Cells) Lavender (EDTA) Infection/immune response
  • RBC (Red Blood Cells) Lavender (EDTA) Oxygen-carrying capacity
  • Hemoglobin (Hgb) Lavender (EDTA) Oxygen transport protein
  • Hematocrit (Hct) Lavender (EDTA) Percentage of blood that is RBCs
  • Platelet count Lavender (EDTA) Clotting ability
  • Differential Lavender (EDTA) Types of WBCs (neutrophils, lymphocytes, etc.)
  • MCV, MCH, MCHC Lavender (EDTA) RBC size and hemoglobin content
  • Lipid Panel

Test Tube Fasting?

  • Total cholesterol Gold SST Recommended
  • HDL cholesterol Gold SST Recommended
  • LDL cholesterol (calculated) Gold SST Recommended
  • Triglycerides Gold SST Yes (most affected by fasting)
  • Coagulation Panel
  • Test Tube What It Measures
  • PT (Prothrombin Time) Light blue (citrate) Extrinsic coagulation pathway; monitors warfarin
  • INR (International Normalized Ratio) Light blue (citrate) Standardized PT ratio

PTT / aPTT (Activated Partial Thromboplastin Time) Light blue (citrate) Intrinsic coagulation pathway; monitors heparin

  • Fibrinogen Light blue (citrate) Clotting factor I level
  • D-dimer Light blue (citrate) Fibrin degradation products (DVT/PE screening)
  • Quality Assurance (QA)

Quality assurance encompasses all activities that ensure reliable laboratory results throughout the total testing process :

Three Phases of the Testing Process

Phase Activities Common Errors

Preanalytical (before testing) Patient ID, specimen collection, labeling, transport, processing Patient misidentification, hemolysis, wrong tube, mislabeling, transport errors

Analytical (during testing) Instrument calibration, reagent quality, running controls, test performance Equipment malfunction, expired reagents, human calculation errors

Postanalytical (after testing) Result reporting, interpretation, documentation, critical value notification Reporting errors, delayed results, wrong patient association

Key Fact: The preanalytical phase accounts for 46-68% of all laboratory errors — this is the phase that phlebotomists directly control.

Delta Checks

A delta check compares a patient's current test results with their previous results:

If the current result differs significantly from the historical result, the system flags it for review

Delta checks help identify:

  • Specimen mislabeling (results don't match the patient's history)
  • Significant clinical changes (genuine medical deterioration or improvement)
  • Technical errors (wrong tube, hemolysis, contamination)
  • Lab Requisition Forms

Every blood collection must be accompanied by a lab requisition form (paper or electronic) that includes:

  • Required Information Details
  • Patient name Full legal name
  • Date of birth / MRN Patient identifier
  • Ordering physician Who ordered the tests
  • Tests requested Specific tests or panels
  • Date/time ordered When the order was placed
  • Diagnosis / ICD code Medical justification for the test
  • Priority Routine, STAT, ASAP, timed
  • Special instructions Fasting, timed draw, special handling
  • Specimen source Venous, arterial, capillary
  • Quality Control (QC) vs. Quality Assurance (QA)

Understanding the difference between QC and QA is important for the exam:

Concept Definition Examples

Quality Control (QC) Specific procedures that monitor the accuracy of the testing process itself Running control samples, calibrating instruments, checking reagent lot numbers

Quality Assurance (QA) The comprehensive program that monitors the ENTIRE testing process from specimen collection to result reporting Patient ID verification, specimen labeling audits, turnaround time monitoring, proficiency testing, delta checks

Preanalytical Quality Indicators

  • Indicator Target How to Monitor
  • Patient identification errors 0% (zero tolerance) Wristband audits, labeling audits
  • Specimen rejection rate <1% of total specimens Track rejection reasons monthly
  • Hemolysis rate <2% of specimens Monitor HIL index on analyzers
  • Specimen labeling errors 0% (zero tolerance) Random audits, barcode verification
  • Turnaround time (TAT) Per test-specific targets Track from collection to result
  • Recollection rate <1% Monitor reasons for recollection
  • Patient complaints Minimize Track and investigate all complaints
  • CLIA (Clinical Laboratory Improvement Amendments)

CLIA regulates all clinical laboratory testing in the United States:

CLIA Category Complexity Examples Requirements

Waived tests Low complexity Glucose meters, urine dipsticks, rapid strep, pregnancy tests Manufacturer instructions; minimal oversight

Moderate complexity Moderate Automated hematology, chemistry, urinalysis Documented training, QC, proficiency testing

High complexity High Manual cell differentials, flow cytometry, molecular testing Advanced training, extensive QC, proficiency testing

Key Fact: Many POCT (point-of-care) tests that phlebotomists may perform are CLIA-waived, but they still require proper training, quality control, and documentation.

Critical Values

Critical values (also called panic values or alert values) are test results that indicate a life-threatening condition requiring immediate physician notification:

Common Critical Values

  • Test Critical Low Critical High
  • Glucose <40 mg/dL (hypoglycemia) >500 mg/dL (hyperglycemia)
  • Potassium <2.5 mEq/L >6.5 mEq/L
  • Sodium <120 mEq/L >160 mEq/L
  • Hemoglobin <7 g/dL >20 g/dL
  • Platelet count <20,000/mcL >1,000,000/mcL
  • WBC <2,000/mcL >30,000/mcL
  • PT/INR — INR >5.0
  • Troponin — Above reference range (varies by assay)
  • Critical Value Reporting Protocol
  • Verify the result — rerun the test if there is any question
  • Call the ordering physician or authorized provider within 30 minutes of result verification

Document the following:

  • Date and time of the call
  • Who was notified (name and title)
  • The critical value reported
  • Read-back confirmation (the recipient must repeat the value back)
  • If the physician cannot be reached, follow the facility's escalation protocol
  • Medical Terminology for Phlebotomists

Phlebotomists should know common medical terminology related to blood and laboratory testing:

Blood-Related Prefixes and Suffixes

  • Term Meaning Example
  • Hem/o, Hemat/o Blood Hematology (study of blood)
  • Ven/o, Phleb/o Vein Venipuncture, phlebotomy
  • Arteri/o Artery Arterial blood gas
  • emia Blood condition Anemia (low RBCs), bacteremia (bacteria in blood)
  • osis Abnormal condition Thrombosis (blood clot)
  • lysis Destruction Hemolysis (RBC destruction)
  • penia Deficiency Thrombocytopenia (low platelets)
  • cytosis Increase in cells Leukocytosis (high WBCs)
  • stasis Stopping Hemostasis (stopping of bleeding)
  • centesis Puncture to withdraw fluid Amniocentesis, arthrocentesis
  • Common Abbreviations
  • Abbreviation Meaning
  • CBC Complete blood count
  • BMP Basic metabolic panel
  • CMP Comprehensive metabolic panel
  • PT Prothrombin time
  • PTT / aPTT (Activated) partial thromboplastin time
  • INR International normalized ratio
  • ESR Erythrocyte sedimentation rate
  • GTT Glucose tolerance test
  • ABG Arterial blood gas
  • H&H Hemoglobin and hematocrit
  • STAT Immediately (from Latin "statim")
  • QNS Quantity not sufficient
  • POCT Point-of-care testing
  • FBS Fasting blood sugar
  • PKU Phenylketonuria
  • Point-of-Care Testing (POCT)

Point-of-care testing (also called bedside testing or near-patient testing) provides rapid results at or near the patient:

Common POCT Tests

  • Test Method Turnaround
  • Glucose Glucometer (finger stick) 5-10 seconds
  • Hemoglobin / Hematocrit HemoCue or i-STAT 1-2 minutes
  • INR / PT CoaguChek 1-2 minutes
  • HbA1c DCA Vantage 5-6 minutes
  • Blood gases i-STAT or ABL 2-3 minutes
  • Pregnancy (hCG) Urine or blood test strip 3-5 minutes
  • Strep A Rapid antigen test 5-10 minutes
  • Troponin Point-of-care immunoassay 10-15 minutes
  • POCT Quality Requirements
  • Operator training required — documented competency assessment
  • Quality control (QC) must be run per manufacturer guidelines (daily, with each new lot, etc.)
  • Results must be documented in the patient's medical record
  • Proficiency testing — POCT instruments must participate in external quality assessment programs
  • Instrument maintenance — cleaning, calibration per manufacturer schedule

Distribution of Laboratory Errors by Phase (Approximate)